1
|
Cuffaro F, Dahm G, Marson C, Berlemont P, Yegles M, Allar C, Fauchet L, Creta M, Schneider S. Contamination of a drug consumption room with drugs and potential risks for social health care workers. Harm Reduct J 2024; 21:149. [PMID: 39148047 PMCID: PMC11328477 DOI: 10.1186/s12954-024-01074-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 08/08/2024] [Indexed: 08/17/2024] Open
Abstract
BACKGROUND Studies have shown that contamination of surfaces by illicit drugs frequently occurs in forensic laboratories when manipulating seized samples as well as in pharmacies and hospitals when preparing medicinal drugs. In this project, we extended these studies to a Drug Consumption Room to investigate drug levels and possible exposure of the staff members. METHODS We investigated pre and post cleaning contamination by heroin and cocaine and their degradation products 6-monoacetylmorphine and benzoylecgonine on different surfaces (tables, counters, computers and door handles) and in the ambient air. We also collected urine and hair samples from staff members to check for potential short and long term contaminations. RESULTS Medium to heavy contamination has been detected on most surfaces and door handles; as expected, air contamination was particularly high in the smoking room. Drug levels were < LOD to very low in the urine and the hair samples of staff members tested. CONCLUSION The cleaning efficiency of the surfaces, carried out by staff and drug users after drug consumption, was often not satisfactory. The very low drug levels in hair indicate that acute health risks for staff members are low.
Collapse
Affiliation(s)
- Flore Cuffaro
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Georges Dahm
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Claude Marson
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Patrick Berlemont
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Michel Yegles
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Claudia Allar
- , Abrigado, 8, Route de Thionville, L-2610, Luxembourg
| | | | - Matteo Creta
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| | - Serge Schneider
- Laboratoire national de santé, 1, rue Louis Rech, Dudelange, L-3555, Luxembourg
| |
Collapse
|
2
|
Wallace WE, Moorthy AS. NIST Mass Spectrometry Data Center standard reference libraries and software tools: Application to seized drug analysis. J Forensic Sci 2023; 68:1484-1493. [PMID: 37203286 PMCID: PMC10517720 DOI: 10.1111/1556-4029.15284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/27/2023] [Accepted: 05/04/2023] [Indexed: 05/20/2023]
Abstract
The standard reference libraries and associated custom software provided by the National Institute of Standards and Technology's Mass Spectrometry Data Center (NIST MSDC) are described with a focus on assisting the seized drug analyst with the identification of fentanyl-related substances (FRS). These tools are particularly useful when encountering novel substances when no certified sample is available. The MSDC provides three standard reference mass spectral libraries, as well as six software packages for mass spectral analysis, reference library searching, data interpretation, and measurement uncertainty estimation. Each of these libraries and software packages are described with references to the original publications provided. Examples of fentanyl identification by gas chromatography-mass spectrometry (GC-MS) and by direct analysis in real-time (DART) mass spectrometry are given. A link to online tutorials is provided.
Collapse
Affiliation(s)
- William E Wallace
- Mass Spectrometry Data Center, Biomolecular Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| | - Arun S Moorthy
- Mass Spectrometry Data Center, Biomolecular Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| |
Collapse
|
3
|
Gupta S, Samal N. Application of direct analysis in real-time mass spectrometry (DART-MS) in forensic science: a comprehensive review. EGYPTIAN JOURNAL OF FORENSIC SCIENCES 2022. [DOI: 10.1186/s41935-022-00276-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
As the rate of crime is constantly increasing, the workload on the forensic analyst also piles up. The availability of a limited number of seized samples makes it crucial to directly analyze the sample, thereby preventing wastage in the prior steps of sample preparation. Due to such needs, the forensic community is consistently working on broadening the usage of direct analysis in real-time mass spectrometry (DART-MS). DART-MS is a relatively new technique for rapid mass spectral analysis. Its use for chemical analysis credits its ability to analyze the sample at atmospheric pressure.
Main body
This article gives insight into the ionization mechanisms, data analysis tools, and the use of hyphenated techniques like thermal-desorption-DART-MS, infrared-thermal-desorption-DART-MS, Joule-heating thermal-desorption-DART-MS, etc. This review summarizes the applications of DART-MS in the field of Forensic Science reported from 2005 to 2021. The applications include analysis of drugs, warfare agents, gun-shot residues, ink differentiation, and other forensically relevant samples. The paper also presents the relation between the type of DART-MS technique and the ionization mode used for a particular class of compounds.
Conclusion
The review follows that the high-resolution mass-spectrometers or low-resolution mass-spectrometers systems in the positive or negative mode were highly dependent on the type of analyte under investigation. Drugs, inks, dyes, and paints were mainly analyzed using the positive ionization mode in the HRMS technique. The examinations of fire accelerants predominantly used the positive ionization mode in the LRMS technique. Moreover, the limit of detection values obtained from the qualitative screening of street drugs were of ppb level, indicating high sensitivity of DART-MS. Considering the work done in the past years, there are potential future research needs of this technology, especially in forensic science.
Graphical Abstract
Collapse
|
4
|
Amaral M, Hatten E, Gibson A, Morgan R. The impact of force, time, and rotation on the transfer of ammonium nitrate: A reductionist approach to understanding evidence dynamics. Sci Justice 2022; 62:129-136. [DOI: 10.1016/j.scijus.2021.12.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 11/05/2021] [Accepted: 12/20/2021] [Indexed: 02/03/2023]
|
5
|
Sisco E, Robinson EL, Mead R, Miller CR. Measuring changes in drug particulate on evidence packaging due to routine case analysis. Forensic Chem 2021. [DOI: 10.1016/j.forc.2021.100372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
6
|
Guo X, Shang Y, Lv Y, Bai H, Ma Q. Suspect Screening of Fentanyl Analogs Using Matrix-Assisted Ionization and a Miniature Mass Spectrometer with a Custom Expandable Mass Spectral Library. Anal Chem 2021; 93:10152-10159. [PMID: 34254788 DOI: 10.1021/acs.analchem.1c01117] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The reliable identification of fentanyl and its analogs is of great significance for public security. However, with the growing prevalence of fentanyl compounds, current analytical strategies cannot fully meet the need for fast and high-throughput detection. In this study, a simple, rapid, and on-site analytical protocol was developed based on a miniature mass spectrometer. A dramatically simplified workflow was implemented using matrix-assisted ionization, bypassing complex sample pretreatment and chromatographic separation. The tandem mass spectrometry (MS/MS) capability afforded by the miniature ion trap mass spectrometer facilitated the investigation of fragmentation patterns for 49 fentanyl analogs during collision-induced dissociation, revealing valuable information on marker fragment ions and characteristic neutral loss. Calculations on Laplacian bond order values further verified the mass spectrometric behavior. A computation-assisted expandable mass spectral library was constructed in-house for fentanyl compounds. Smart suspect screening was carried out based on the full-scan MS and MS/MS data. The present study demonstrates an appealing potential for forensic applications, enabling streamlined screening for the presence of illicit fentanyl compounds at the point of seizures of suspect samples.
Collapse
Affiliation(s)
- Xiangyu Guo
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Yuhan Shang
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Yueguang Lv
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hua Bai
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
7
|
Kosecki PA, Autret A, Abbott L, Keller-Brooke K. Isobutylene contamination of blood collected in 10-ml evacuated blood collection tubes with gray conventional rubber stoppers. J Forensic Sci 2021; 66:2484-2492. [PMID: 34250598 DOI: 10.1111/1556-4029.14792] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/28/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022]
Abstract
Dual-column headspace gas chromatographic analysis with two flame-ionization detectors is a commonly used analytical technique for forensic blood ethanol quantitation. This technique is also applicable to the identification and quantitation of other volatile organic compounds such as methanol in biological samples. Compound identification by retention time is limited to those compounds with known retention times programmed into the instrument method. Historically, an early-eluting peak from an unidentified compound has been observed in both chromatograms from antemortem blood samples analyzed for ethanol concentration with this technique. The unidentified compound's retention time matches that of methanol on one column but not on the second column. This previously unidentified compound has been identified as isobutylene. The proposed source of the isobutylene contamination historically observed in antemortem blood samples collected in 10-ml gray-top blood collection tubes is the conventional rubber stopper. Isobutylene was detected in deionized water stored in each of the seven lots of 10-ml blood tubes tested; the expiration dates of the tubes tested spanned the years 2002-2022. Misidentification of isobutylene as methanol is possible when using a single-column gas chromatographic system. The presence of isobutylene in blood collected in a gray-top collection tube does not represent laboratory contamination, is not an interferent with blood ethanol quantitation, and does not affect the ethanol concentration in the blood. A 0.150 g/dl aqueous ethanol standard was stored in a gray-top tube to evaluate the potential impact of isobutylene on ethanol quantitation. The solution's average ethanol concentration measured after storage was 0.150 g/dl.
Collapse
Affiliation(s)
| | - Amy Autret
- Tucson Police Department Crime Laboratory, Tucson, AZ, USA
| | - Lori Abbott
- Scottsdale Police Department Crime Laboratory, Scottsdale, AZ, USA
| | | |
Collapse
|
8
|
Sisco E, Staymates ME, Watt LM. Net Weights: Visualizing and Quantifying their Contribution to Drug Background Levels in Forensic Laboratories. Forensic Chem 2021; 20. [PMID: 34151050 DOI: 10.1016/j.forc.2020.100259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
While the drug background in forensic laboratories has been quantified, the processes that most contribute to the background have not been extensively researched. This work presents both qualitative visualization and quantitative analysis of the spread of simulant drug particulate during the process of taking net weights. The process was modeled using three masses of powder (0.2 g, 2 g, and 100 g). The net weight process, in which the mixture was poured onto weighing paper, was mimicked and the resulting aerosolized particulate was allowed to settle. Wetted cotton swabs were then used to sample 6.45 cm2 (1 in2) squares extending up to 61 cm (24 in) away from the weigh paper. The swabs were then extracted and quantified using LC-MS/MS and two-dimensional color plots were created to visualize the magnitude of particulate spread. Qualitative flow visualization of the process, accomplished using laser light sheet videography, was also completed to support the quantitative extraction experiments and provide a visual representation of the mechanism of particulate spread. Surface concentrations were found to be highest in the area immediately surrounding the weigh paper, though transport as far as 61 cm (24 in) was observed with all mass loadings. The amount of the material aerosolized and transported on the bench surrounding the weigh paper was dependent upon the mass of material being poured. These results highlight that weighing activities encountered in forensic labs may be a primary contributor to drug background and may be a potential source of inhalation exposure for chemists.
Collapse
|
9
|
Sisco E, Staymates ME, Burns A. An easy to implement approach for laboratories to visualize particle spread during the handling and analysis of drug evidence. Forensic Chem 2020. [DOI: 10.1016/j.forc.2020.100232] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
10
|
Sisco E, Staymates ME, Burns A. An Easy to Implement Approach for Laboratories to Visualize Particle Spread During the Handling and Analysis of Drug Evidence. Forensic Chem 2020; 18:https://doi.org/10.1016/j.forc.2020.100232. [PMID: 33102988 PMCID: PMC7580037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Recent work has shown that detectable levels of drugs exists on nearly all surfaces within a forensic laboratory - especially within the drug chemistry unit. This is an expected occurrence due to the handling and opening of drug evidence that contains powder material. The process of opening evidence, which produces aerosolized particulate that can settle on surfaces throughout the lab, has never been visualized. This work presents the first attempt to visualize the spread of particulate throughout the laboratory during the analysis of drug evidence and introduces an easy to implement approach laboratories can use to evaluate their specific protocols. By creating two simulated bricks of drugs that contained fluorescent particles, the spread of particulate was able to be monitored throughout the evidence handling process up to and including cleaning of surfaces after analysis. The protocols in this work, showed the spread of particulate, prior to cleaning, to be quite extensive, with transfer onto surfaces and items that were handled. In this study, cleaning with methanol after processing the evidence was shown to be effective at removing nearly all particulate that was released in the process. The use of visualization techniques such as this demonstrate promise for helping laboratories identify processes in their own protocols that may contribute to drug background levels and educate forensic chemists how trace residues spread.
Collapse
Affiliation(s)
| | | | - Amber Burns
- Maryland State Police Forensic Sciences Division
| |
Collapse
|
11
|
Forbes TP, Lawrence J, Verkouteren JR, Verkouteren RM. Discriminative potential of ion mobility spectrometry for the detection of fentanyl and fentanyl analogues relative to confounding environmental interferents. Analyst 2019; 144:6391-6403. [PMID: 31579898 PMCID: PMC7008973 DOI: 10.1039/c9an01771b] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The opioid crisis and emergence of fentanyl, fentanyl analogues, and other synthetic opioids has highlighted the need for sensitive and robust detection for interdiction at screening points, notably vehicles at border crossings and packages at postal facilities. This work investigates the discriminative potential, sensitivity and specificity, of ion mobility spectrometry (IMS) for the detection of fentanyl and fifteen (15) fentanyl-related compounds (analogues, other opioids, and metabolites) relative to confounding environmental interferents. The environmental background interferent levels, frequency and intensity, were derived from over 10 000 screening samples collected from delivery vehicles entering a federal site. A receiver operating characteristic (ROC) curve methodology was employed to quantify the relationship between sensitivity and specificity for these target compounds on two instruments/configurations. These instrument configurations differed in desorption and drift tube temperatures, reactant ion dopant chemistry, and analysis time. This work identified reduced mobility areas of high interference that resulted in increased false positive rates (FPR), effectively reducing sensitivity (true positive rate: TPR) in those regions. Except for a few target compounds on either of the instruments that exhibited elevated FPRs, detection of fentanyl and fentanyl-related species was achieved at single to tens of nanograms with ≥90% TPR and ≤2% FPR. This work established the importance of systematic environmental background characterization at each specific screening setting in evaluating a platform's true performance.
Collapse
Affiliation(s)
- Thomas P Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA.
| | | | | | | |
Collapse
|
12
|
What's in the bag? Analysis of exterior drug packaging by TD-DART-MS to predict the contents. Forensic Sci Int 2019; 304:109939. [PMID: 31580981 DOI: 10.1016/j.forsciint.2019.109939] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 08/07/2019] [Accepted: 08/24/2019] [Indexed: 12/18/2022]
Abstract
The need for a safe and reliable presumptive test for law enforcement, first responders, and laboratory personnel is critical in the era of dangerous synthetic opioids and other novel psychoactive substances. Obtaining drug identification information without handling bulk powder is one way of accomplishing this task. This work evaluates whether trace residue on the exterior of drug packaging presents a potential source for presumptive testing. Utilizing a wipe-based approach, the outside of the packaging of nearly 200 case exhibits were sampled and analyzed by thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS). While residue on the law enforcement (outer) packaging was a poor indicator of the contents (less than 50% accurate), the exterior of the drug (inner) packaging was shown to be an excellent indicator of its contents (92% accurate). Quantitative analysis of the wipes, using liquid chromatography mass spectrometry (LC-MS/MS) showed that typical masses of residue on the exterior of packaging ranged from single to tens of micrograms - enough for detection by a number of trace detection tools. These initial results demonstrate that wipe-based trace sampling approaches present a promising, reliable, and safe method for presumptive testing by law enforcement, first responders, or laboratory personnel.
Collapse
|
13
|
Sisco E, Najarro M, Burns A. Quantifying the effectiveness of cleaning agents at removing drugs from laboratory benches and floor tiles. Forensic Chem 2019. [DOI: 10.1016/j.forc.2018.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
14
|
Sisco E, Najarro M. A multi-laboratory investigation of drug background levels. Forensic Chem 2019; 16:10.1016/j.forc.2019.100184. [PMID: 32118122 PMCID: PMC7047777 DOI: 10.1016/j.forc.2019.100184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Identifying and quantifying the drug background in operational environments such as forensic laboratories is an emerging body of research. Knowing these levels is crucial to addressing issues like occupational exposure risk - due to the emergence of potent novel psychoactive substances and synthetic opioids - and data integrity - due to improvements in instrument sensitivity. The work presented here builds upon a prior study to provide a broader representation of the average drug background levels found on surfaces in forensic laboratories. Over 700 samples from 20 laboratories were collected, extracted, and analyzed quantitatively using LC-MS/MS, and qualitatively using TD-DART-MS. Quantitative analysis by LC-MS/MS included a panel of 18 drugs while the non-targeted qualitative analysis by TD-DART-MS screened for over three hundred drugs and excipients. The study focused primarily on surfaces within the drug unit and evidence receiving area of the laboratories, but also investigated other operational units (crime scene, drug interdiction, latent prints, and toxicology) as well as report writing. Background levels were highest within the drug unit of the laboratory, though detectable (tens of nanograms) levels were observed in nearly all sampled areas. The data from this expanded study plays a critical role in addressing laboratory concerns such as establishing drug identification reporting limits for new instrumentation and establishing new workflow or cleaning protocols while also providing a more comprehensive dataset for general environmental background studies.
Collapse
Affiliation(s)
- Edward Sisco
- National Institute of Standards and Technology, Gaithersburg, MD 20899, United States
| | - Marcela Najarro
- National Institute of Standards and Technology, Gaithersburg, MD 20899, United States
| |
Collapse
|