Horsak B, Durstberger S, Krondorfer P, Thajer A, Greber-Platzer S, Kranzl A. Which method should we use to determine the hip joint center location in individuals with a high amount of soft tissue? Clin Biomech (Bristol, Avon) 2024; 115:106254. [PMID: 38669918 DOI: 10.1016/j.clinbiomech.2024.106254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 03/26/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024]
Abstract
BACKGROUND This study investigated the most accurate method for estimating the hip joint center position in clinical 3D gait analysis for young individuals with high amounts of soft tissue. We compared position estimates of five regression-based and two functional methods to the hip joint center position obtained through 3D free-hand ultrasound. METHODS For this purpose, the data of 14 overweight or obese individuals with a mean age of 13.6 (SD 2.1 yrs) and a BMI of 36.5 (SD 7.1 kg/m2, range 26-52 kg/m2) who underwent standard clinical 3D gait analysis were used. The data of each participant were processed with five regression-based and two functional methods and compared to the hip joint center identified via 3D free-hand ultrasound. FINDINGS The absolute location errors to 3D free-hand ultrasound for each anatomical plane and the Euclidean distances served as outcomes next to their effects on gait variables. The data suggest that regression-based methods are preferable to functional methods in this population, as the latter demonstrated the highest variability in accuracy with large errors for some individuals. INTERPRETATION Based on our findings we recommend using the regression method presented by Hara et al. due to its superior overall accuracy of <9 mm on average in all planes and the lowest impact on kinematic and kinetic output variables. We do not recommend using the Harrington equations (single and multiple) in populations with high amounts of soft tissue as they require pelvic depth as input, which can be massively biased when a lot of soft tissue is present around the pelvis.
Collapse
Affiliation(s)
- Brian Horsak
- Center for Digital Health and Social Innovation, St. Pölten University of Applied Sciences, Campus-Platz 1, St. Pölten 3100, Austria; Institute of Health Sciences, St. Pölten University of Applied Sciences, Campus-Platz 1, St. Pölten 3100, Austria.
| | - Sebastian Durstberger
- FH Campus Wien - University of Applied Sciences, Department Health Sciences, Favoritenstrasse 226, 1100 Vienna, Austria; Orthopaedic Hospital Speising, Laboratory of Gait and Movement Analysis, Speisinger Str. 109, Vienna 1130, Austria
| | - Philipp Krondorfer
- Center for Digital Health and Social Innovation, St. Pölten University of Applied Sciences, Campus-Platz 1, St. Pölten 3100, Austria
| | - Alexandra Thajer
- Clinical Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Währinger Guertel 18-20, Vienna 1090, Austria
| | - Susanne Greber-Platzer
- Clinical Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Währinger Guertel 18-20, Vienna 1090, Austria
| | - Andreas Kranzl
- Orthopaedic Hospital Speising, Laboratory of Gait and Movement Analysis, Speisinger Str. 109, Vienna 1130, Austria
| |
Collapse
|
2
|
3D free-hand ultrasound to register anatomical landmarks at the pelvis and localize the hip joint center in lean and obese individuals. Sci Rep 2021; 11:10650. [PMID: 34017023 PMCID: PMC8170673 DOI: 10.1038/s41598-021-89763-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 04/28/2021] [Indexed: 11/25/2022] Open
Abstract
3D free-hand ultrasound (3DFUS) is becoming increasingly popular to assist clinical gait analysis because it is cost- and time-efficient and does not expose participants to radiation. The aim of this study was to evaluate its reliability in localizing the anterior superior iliac spine (ASIS) at the pelvis and the hip joint centers (HJC). Additionally, we evaluated its accuracy to get a rough estimation of the potential to use of 3DFUS to segment bony surface. This could offer potential to register medical images to motion capture data in future. To evaluate reliability, a test–retest study was conducted in 16 lean and 19 obese individuals. The locations of the ASIS were determined by manual marker placement (MMP), an instrumented pointer technique (IPT), and with 3DFUS. The HJC location was also determined with 3DFUS. To quantify reliability, intraclass correlation coefficients (ICCs), the standard error of measurement (SEm), among other statistical parameters, were calculated for the identified locations between the test and retest. To assess accuracy, the surface of a human plastic pelvic phantom was segmented with 3DFUS in a distilled water bath in 27 trials and compared to a 3D laser scan of the pelvis. Regarding reliability, the MMP, but especially the IPT showed high reliability in lean (SEm: 2–3 mm) and reduced reliability in obese individuals (SEm: 6–15 mm). Compared to MMP and IPT, 3DFUS presented lower reliability in the lean group (SEm: 2–4 mm vs. 2–8 mm, respectively) but slightly better values in the obese group (SEm: 7–11 mm vs. 6–16 mm, respectively). Correlations between test–retest reliability and torso body fat mass (% of body mass) indicated a moderate to strong relationship for MMP and IPT but only a weak correlation for the 3DFUS approach. The water-bath experiments indicated an acceptable level of 3.5 (1.7) mm of accuracy for 3DFUS in segmenting bone surface. Despite some difficulties with single trials, our data give further rise to the idea that 3DFUS could serve as a promising tool in future to inform marker placement and hip joint center location, especially in groups with higher amount of body fat.
Collapse
|
3
|
Bennett HJ, Valenzuela KA, Fleenor K, Weinhandl JT. A Normative Database of Hip and Knee Joint Biomechanics During Dynamic Tasks Using Four Functional Methods With Three Functional Calibration Tasks. J Biomech Eng 2020; 142:958437. [PMID: 31513696 DOI: 10.1115/1.4044503] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Indexed: 12/13/2022]
Abstract
Although predicted hip joint center (HJC) locations are known to vary widely between functional methods, no previous investigation has detailed functional method-dependent hip and knee biomechanics. The purpose of this study was to define a normative database of hip joint biomechanics during dynamic movements based upon functional HJC methods and calibration tasks. Thirty healthy young adults performed arc, star arc, and two-sided calibration tasks. Motion capture and ground reaction forces were collected during walking, running, and single-leg landings (SLLs). Two sphere-fit (geometric and algebraic) and two coordinate transformation techniques were implemented using each calibration (12 total method-calibration combinations). Surprisingly, the geometric fit-two-sided model placed the HJC at the midline of the pelvis and above the iliac spines, and thus was removed from analyses. A database of triplanar hip and knee kinematics and hip moments and powers was constructed using the mean of all subjects for the eleven method-calibration combinations. A nested analysis of variance approach compared calibration [method] peak hip kinematics and kinetics. Most method differences existed between geometric fit and coordinate transformations (58 of 84 total). No arc-star arc differences were found. Thirty-two differences were found between the two-sided and arc/star arc calibrations. This database of functional method based hip and knee biomechanics serves as an important reference point for interstudy comparisons. Overall, this study illustrates that functional HJC method can dramatically impact hip biomechanics and should be explicitly detailed in future work.
Collapse
Affiliation(s)
- Hunter J Bennett
- Department of Human Movement Sciences, Old Dominion University, 2016 Student Recreation Center, Norfolk, VA 23529
| | - Kevin A Valenzuela
- Department of Kinesiology, HHS2-203, California State University Long Beach, Long Beach, CA 90840
| | - Kristina Fleenor
- Department of Human Movement Sciences, Old Dominion University, 2016 Student Recreation Center, Norfolk, VA 23529
| | - Joshua T Weinhandl
- Department of Kinesiology, Recreation, and Sport Studies, The University of Tennessee, 322 HPER Building, 1914 Andy Holt Avenue, Knoxville, TN 37996-2700
| |
Collapse
|
4
|
Leboeuf F, Reay J, Jones R, Sangeux M. The effect on conventional gait model kinematics and kinetics of hip joint centre equations in adult healthy gait. J Biomech 2019; 87:167-171. [DOI: 10.1016/j.jbiomech.2019.02.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 02/12/2019] [Accepted: 02/14/2019] [Indexed: 10/27/2022]
|
5
|
Pizzolato C, Lloyd DG, Barrett RS, Cook JL, Zheng MH, Besier TF, Saxby DJ. Bioinspired Technologies to Connect Musculoskeletal Mechanobiology to the Person for Training and Rehabilitation. Front Comput Neurosci 2017; 11:96. [PMID: 29093676 PMCID: PMC5651250 DOI: 10.3389/fncom.2017.00096] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Accepted: 10/04/2017] [Indexed: 12/20/2022] Open
Abstract
Musculoskeletal tissues respond to optimal mechanical signals (e.g., strains) through anabolic adaptations, while mechanical signals above and below optimal levels cause tissue catabolism. If an individual's physical behavior could be altered to generate optimal mechanical signaling to musculoskeletal tissues, then targeted strengthening and/or repair would be possible. We propose new bioinspired technologies to provide real-time biofeedback of relevant mechanical signals to guide training and rehabilitation. In this review we provide a description of how wearable devices may be used in conjunction with computational rigid-body and continuum models of musculoskeletal tissues to produce real-time estimates of localized tissue stresses and strains. It is proposed that these bioinspired technologies will facilitate a new approach to physical training that promotes tissue strengthening and/or repair through optimal tissue loading.
Collapse
Affiliation(s)
- Claudio Pizzolato
- School of Allied Health Sciences, Griffith University, Gold Coast, QLD, Australia
- Gold Coast Orthopaedic Research and Education Alliance, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - David G. Lloyd
- School of Allied Health Sciences, Griffith University, Gold Coast, QLD, Australia
- Gold Coast Orthopaedic Research and Education Alliance, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Rod S. Barrett
- School of Allied Health Sciences, Griffith University, Gold Coast, QLD, Australia
- Gold Coast Orthopaedic Research and Education Alliance, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Jill L. Cook
- La Trobe Sport and Exercise Medicine Research Centre, La Trobe University, Melbourne, VIC, Australia
| | - Ming H. Zheng
- Centre for Orthopaedic Translational Research, School of Surgery, University of Western Australia, Nedlands, WA, Australia
| | - Thor F. Besier
- Auckland Bioengineering Institute and Department of Engineering Science, University of Auckland, Auckland, New Zealand
| | - David J. Saxby
- School of Allied Health Sciences, Griffith University, Gold Coast, QLD, Australia
- Gold Coast Orthopaedic Research and Education Alliance, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| |
Collapse
|
6
|
Mozaffari MH, Lee WS. Freehand 3-D Ultrasound Imaging: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2099-2124. [PMID: 28716431 DOI: 10.1016/j.ultrasmedbio.2017.06.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 06/01/2017] [Accepted: 06/05/2017] [Indexed: 05/20/2023]
Abstract
Two-dimensional ultrasound (US) imaging has been successfully used in clinical applications as a low-cost, portable and non-invasive image modality for more than three decades. Recent advances in computer science and technology illustrate the promise of the 3-D US modality as a medical imaging technique that is comparable to other prevalent modalities and that overcomes certain drawbacks of 2-D US. This systematic review covers freehand 3-D US imaging between 1970 and 2017, highlighting the current trends in research fields, the research methods, the main limitations, the leading researchers, standard assessment criteria and clinical applications. Freehand 3-D US systems are more prevalent in the academic environment, whereas in clinical applications and industrial research, most studies have focused on 3-D US transducers and improvement of hardware performance. This topic is still an interesting active area for researchers, and there remain many unsolved problems to be addressed.
Collapse
Affiliation(s)
- Mohammad Hamed Mozaffari
- School of Electrical Engineering and Computer Science (EECS), University of Ottawa, Ottawa, Ontario, Canada.
| | - Won-Sook Lee
- School of Electrical Engineering and Computer Science (EECS), University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
7
|
Reliability of Achilles Tendon Moment Arm Measured In Vivo Using Freehand Three-Dimensional Ultrasound. J Appl Biomech 2017; 33:300-304. [PMID: 28084870 DOI: 10.1123/jab.2016-0261] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This study investigated reliability of freehand three-dimensional ultrasound (3DUS) measurement of in vivo human Achilles tendon (AT) moment arm. Sixteen healthy adults were scanned on 2 separate occasions by a single investigator. 3DUS scans were performed over the free AT, medial malleolus, and lateral malleolus with the ankle passively positioned in maximal dorsiflexion, mid dorsiflexion, neutral, mid plantar flexion and maximal plantar flexion. 3D reconstructions of the AT, medial malleolus, and lateral malleolus were created from manual segmentation of the ultrasound images and used to geometrically determine the AT moment arm using both a straight (straight ATMA) and curved (curved ATMA) tendon line-of-action. Both methods were reliable within- and between-session (intra-class correlation coefficients > 0.92; coefficient of variation < 2.5 %) and revealed that AT moment arm increased by ∼ 7 mm from maximal dorsiflexion (∼ 41mm) to maximal plantar flexion (∼ 48 mm). Failing to account for tendon curvature led to a small overestimation (< 2 mm) of AT moment arm that was most pronounced in ankle plantar flexion, but was less than the minimal detectable change of the method and could be disregarded.
Collapse
|
8
|
Bennett HJ, Shen G, Weinhandl JT, Zhang S. Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods. J Biomech 2016; 49:3047-3051. [DOI: 10.1016/j.jbiomech.2016.06.013] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 06/07/2016] [Accepted: 06/09/2016] [Indexed: 12/01/2022]
|
9
|
Assi A, Sauret C, Massaad A, Bakouny Z, Pillet H, Skalli W, Ghanem I. Validation of hip joint center localization methods during gait analysis using 3D EOS imaging in typically developing and cerebral palsy children. Gait Posture 2016; 48:30-35. [PMID: 27477704 DOI: 10.1016/j.gaitpost.2016.04.028] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Localization of the hip joint center (HJC) is essential in computation of gait data. EOS low dose biplanar X-rays have been shown to be a good reference in evaluating various methods of HJC localization in adults. The aim is to evaluate predictive and functional techniques for HJC localization in typically developing (TD) and cerebral palsy (CP) children, using EOS as an image based reference. Eleven TD and 17 CP children underwent 3D gait analysis. Six HJC localization methods were evaluated in each group bilaterally: 3 predictive (Plug in Gait, Bell and Harrington) and 3 functional methods based on the star arc technique (symmetrical center of rotation estimate, center transformation technique and geometrical sphere fitting). All children then underwent EOS low dose biplanar radiographs. Pelvis, lower limbs and their corresponding external markers were reconstructed in 3D. The center of the femoral head was considered as the reference (HJCEOS). Euclidean distances between HJCs estimated by each of the 6 methods and the HJCEOS were calculated; distances were shown to be lower in predictive compared to functional methods (p<0.0001). Contrarily to findings in adults, functional methods were shown to be less accurate than predictive methods in TD and CP children, which could be mainly due to the shorter thigh segment in children. Harrington method was shown to be the most accurate in the prediction of HJC (mean error≈18mm, SD=9mm) and quasi-equivalent to the Bell method. The bias for each method was quantified, allowing its correction for an improved HJC estimation.
Collapse
Affiliation(s)
- Ayman Assi
- Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, University of Saint-Joseph, Beirut, Lebanon; Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France; Gait Laboratory, SESOBEL, Beirut, Lebanon.
| | - Christophe Sauret
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| | - Abir Massaad
- Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, University of Saint-Joseph, Beirut, Lebanon; Gait Laboratory, SESOBEL, Beirut, Lebanon
| | - Ziad Bakouny
- Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, University of Saint-Joseph, Beirut, Lebanon
| | - Hélène Pillet
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| | - Wafa Skalli
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France
| | - Ismat Ghanem
- Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, University of Saint-Joseph, Beirut, Lebanon; Gait Laboratory, SESOBEL, Beirut, Lebanon; Hôtel-Dieu de France Hospital, Beirut, Lebanon
| |
Collapse
|
10
|
Defining the medial-lateral axis of an anatomical femur coordinate system using freehand 3D ultrasound imaging. Gait Posture 2016; 45:211-6. [PMID: 26979908 DOI: 10.1016/j.gaitpost.2016.02.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 02/04/2016] [Accepted: 02/05/2016] [Indexed: 02/02/2023]
Abstract
Hip rotation from gait analysis informs clinical decisions regarding correction of femoral torsional deformities. However, it is among the least repeatable due to discrepancies in determining the medial-lateral axis of the femur. Conventional or functional calibration methods may be used to define the axis but there is no benchmark to evaluate these methods. Freehand 3D ultrasound, the coupling of ultrasound with 3D motion capture, may provide such a benchmark. We measured the accuracy in vitro and repeatability in vivo of determining the femur condylar axis from freehand 3D ultrasound. The condylar axis provided the reference medial-lateral axis of the femur and was used to evaluate one conventional method and three functional calibration methods, applied to three calibration movements. Ten healthy subjects (20 limbs) underwent 3D gait analysis and freehand 3D ultrasound. The functional calibration methods were a transformation technique, a geometrical method and a method that minimises variance of knee varus-valgus kinematics (DynaKAD). The conventional method used markers over the femoral epicondyles. The condylar axis determined by 3D ultrasound showed good accuracy in vitro, 1.6° (SD: 0.3°) and good repeatability in vivo, 0.2° (RSMD: 2.3°). The DynaKAD method applied to the walking calibration movement determined the medial-lateral axis closest to the ultrasound reference. The average angular difference in the transverse plane was 3.1° (SD: 6.1°). Freehand 3D ultrasound offers an accurate, non-invasive and relatively fast method to locate the medial-lateral axis of the femur for gait analysis.
Collapse
|
11
|
Passmore E, Pandy MG, Graham HK, Sangeux M. Measuring Femoral Torsion In Vivo Using Freehand 3-D Ultrasound Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:619-623. [PMID: 26639301 DOI: 10.1016/j.ultrasmedbio.2015.10.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 10/16/2015] [Accepted: 10/18/2015] [Indexed: 06/05/2023]
Abstract
Despite variation in bone geometry, muscle and joint function is often investigated using generic musculoskeletal models. Patient-specific bone geometry can be obtained from computerised tomography, which involves ionising radiation, or magnetic resonance imaging (MRI), which is costly and time consuming. Freehand 3-D ultrasound provides an alternative to obtain bony geometry. The purpose of this study was to determine the accuracy and repeatability of 3-D ultrasound in measuring femoral torsion. Measurements of femoral torsion were performed on 10 healthy adults using MRI and 3-D ultrasound. Measurements of femoral torsion from 3-D ultrasound were, on average, smaller than those from MRI (mean difference = 1.8°; 95% confidence interval: -3.9°, 7.5°). MRI and 3-D ultrasound had Bland and Altman repeatability coefficients of 3.1° and 3.7°, respectively. Accurate measurements of femoral torsion were obtained with 3-D ultrasound offering the potential to acquire patient-specific bone geometry for musculoskeletal modelling. Three-dimensional ultrasound is non-invasive and relatively inexpensive and can be integrated into gait analysis.
Collapse
Affiliation(s)
- Elyse Passmore
- Hugh Williamson Gait Analysis Laboratory, Royal Children's Hospital, Melbourne, Australia; Murdoch Childrens Research Institute, Melbourne, Australia; Department of Mechanical Engineering, University of Melbourne, Melbourne, Australia.
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Melbourne, Australia
| | - H Kerr Graham
- Hugh Williamson Gait Analysis Laboratory, Royal Children's Hospital, Melbourne, Australia; Murdoch Childrens Research Institute, Melbourne, Australia; Department of Paediatrics, University of Melbourne, Melbourne, Australia
| | - Morgan Sangeux
- Hugh Williamson Gait Analysis Laboratory, Royal Children's Hospital, Melbourne, Australia; Murdoch Childrens Research Institute, Melbourne, Australia; Department of Mechanical Engineering, University of Melbourne, Melbourne, Australia
| |
Collapse
|
12
|
Kainz H, Carty CP, Modenese L, Boyd RN, Lloyd DG. Estimation of the hip joint centre in human motion analysis: a systematic review. Clin Biomech (Bristol, Avon) 2015; 30:319-29. [PMID: 25753697 DOI: 10.1016/j.clinbiomech.2015.02.005] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2014] [Revised: 02/06/2015] [Accepted: 02/06/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Inaccuracies in locating the three-dimensional position of the hip joint centre affect the calculated hip and knee kinematics, force- and moment-generating capacity of muscles and hip joint mechanics, which can lead to incorrect interpretations and recommendations in gait analysis. Several functional and predictive methods have been developed to estimate the hip joint centre location, and the International Society of Biomechanics recommends a functional approach for use with participants that have adequate range of motion at the hip, and predictive methods in those with insufficient range of motion. The purpose of the current systematic review was to substantiate the International Society of Biomechanics recommendations. This included identifying the most accurate functional and predictive methods, and defining 'adequate' range of motion. METHODS A systematic search with broad search terms was performed including five databases. FINDINGS The systematic search yielded to 801 articles, of which 34 papers were included. Eleven different predictive and 13 different functional methods were identified. The results showed that the geometric sphere fit method and Harrington equations are the most accurate functional and predictive approaches respectively that have been evaluated in vivo. INTERPRETATION In regard to the International Society of Biomechanics recommendations, the geometric sphere fit method should be used in people with sufficient active hip range of motion and the Harrington equations should be used in patients without sufficient hip range of motion. Multi-plane movement trials with at least 60° of flexion-extension and 30° of ab-adduction range of motion are suggested when using functional methods.
Collapse
Affiliation(s)
- Hans Kainz
- School of Allied Health Sciences, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Centre for Musculoskeletal Research, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Queensland Children's Gait Laboratory, Queensland Paediatric Rehabilitation Service, Children's Health Queensland Hospital and Health Service, Brisbane, Australia.
| | - Christopher P Carty
- School of Allied Health Sciences, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Centre for Musculoskeletal Research, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Queensland Children's Gait Laboratory, Queensland Paediatric Rehabilitation Service, Children's Health Queensland Hospital and Health Service, Brisbane, Australia
| | - Luca Modenese
- School of Allied Health Sciences, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Centre for Musculoskeletal Research, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia
| | - Roslyn N Boyd
- Queensland Cerebral Palsy and Rehabilitation Research Centre, School of Medicine, The University of Queensland, Brisbane, Australia
| | - David G Lloyd
- School of Allied Health Sciences, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia; Centre for Musculoskeletal Research, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia
| |
Collapse
|
13
|
Najafi M, Afsham N, Abolmaesumi P, Rohling R. A closed-form differential formulation for ultrasound spatial calibration: single wall phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1079-1094. [PMID: 25701520 DOI: 10.1016/j.ultrasmedbio.2014.11.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 10/17/2014] [Accepted: 11/25/2014] [Indexed: 06/04/2023]
Abstract
Calibration is essential in freehand 3-D ultrasound to find the spatial transformation from the image coordinates to the sensor coordinate system. Ease of use, simplicity, precision and accuracy are among the most important factors in ultrasound calibration, especially when aiming to make calibration more reliable for day-to-day clinical use. We introduce a new mathematical framework for the simple and popular single-wall calibration phantom with a plane equation pre-determination step and the use of differential measurements to obtain accurate measurements. The proposed method provides a novel solution for ultrasound calibration that is accurate and easy to perform. This method is applicable to both radiofrequency (RF) and B-mode data, and both linear and curvilinear transducers. For a linear L14-5 transducer, the point reconstruction accuracy (PRA) of reconstructing 370 points is 0.73 ± 0.23 mm using 100 RF images, whereas the triple N-wire PRA is 0.67 ± 0.20 mm using 100 B-mode images. For a curvilinear C5-2 transducer, the PRA using the proposed method is 0.86 ± 0.28 mm on 400 points using 100 RF images, whereas N-wire calibration gives a PRA of 0.80 ± 0.46 mm using 100 B-mode images. Therefore, the accuracy of the proposed variation of the single-wall method using RF data is practically similar to the N-wire method while offering a simpler phantom with no need for accurate design and construction.
Collapse
Affiliation(s)
- Mohammad Najafi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Narges Afsham
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Purang Abolmaesumi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Robert Rohling
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada; Department of Mechanical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.
| |
Collapse
|
14
|
Momi ED, Beretta E, Ferrigno G. Hip joint centre localisation with an unscented Kalman filter. Comput Methods Biomech Biomed Engin 2013; 16:1319-29. [DOI: 10.1080/10255842.2012.670852] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
15
|
Pillet H, Sangeux M, Hausselle J, El Rachkidi R, Skalli W. A reference method for the evaluation of femoral head joint center location technique based on external markers. Gait Posture 2013; 39:655-8. [PMID: 24055179 DOI: 10.1016/j.gaitpost.2013.08.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 07/24/2013] [Accepted: 08/25/2013] [Indexed: 02/02/2023]
Abstract
Accurate localization of joint centers is essential in movement analysis. However, joint centers cannot be directly palpated and alternative methods must be used. To assess the relative merits of these methods, a medical image based reference should be used. The EOS(®) system, a new low dose bi-planar X-rays imaging technique may be considered. The aim of this study was to evaluate the accuracy of hip joint center (HJC) localization using the EOS(®) system. Seventeen healthy young adults participated in the study. Femoral heads and pelvic external markers were localized using the EOS(®) system and the HJCs were expressed in the movement analysis coordinate system. Results showed that external marker localization was reliable within 0.15 mm for trained assessors. Mean accuracy for HJC localization was 2.9 mm (SD: 1.3, max: 6.2). The EOS based method therefore appeared reliable and may be used for femoral head localization or as a reference to assess the accuracy of other methods for HJC localization.
Collapse
Affiliation(s)
- Hélène Pillet
- Arts et Metiers ParisTech, LBM, 151 bd de l'hopital, 75013 Paris, France.
| | | | | | | | | |
Collapse
|
16
|
Lempereur M, Kostur L, Leboucher J, Brochard S, Rémy-Néris O. 3D freehand ultrasound to estimate the glenohumeral rotation centre. Comput Methods Biomech Biomed Engin 2013; 16 Suppl 1:214-5. [DOI: 10.1080/10255842.2013.815854] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
17
|
Peters A, Baker R, Morris ME, Sangeux M. A comparison of hip joint centre localisation techniques with 3-DUS for clinical gait analysis in children with cerebral palsy. Gait Posture 2012; 36:282-6. [PMID: 22560716 DOI: 10.1016/j.gaitpost.2012.03.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2011] [Revised: 02/02/2012] [Accepted: 03/15/2012] [Indexed: 02/02/2023]
Abstract
Functional calibration techniques have been proposed as an alternative to regression equations for estimating the position of the hip within the pelvic co-ordinate system for clinical gait analysis. So far validation of such techniques has focussed on healthy adults. This study evaluated a range of techniques based on regression equations or functional calibration procedures techniques in 46 children representative of those attending a major clinical gait analysis service against previously validated 3-D ultrasound techniques for determining the hip joint centre. Best agreement with ultrasound for the position of the hip within the pelvic coordinate system was found for the Harrington equations (mean 14 mm, sd 8 mm). Sphere fitting (mean≈22 mm, sd 11 mm) performed better than transformational techniques applied locally (mean≈33 mm, sd 12 mm) or globally (mean=30 mm, sd 14 mm). The participants with cerebral palsy showed reduced range of movement compared with healthy adults. Differences between these results and studies modelling the effects of simulated noise on functional techniques can probably be attributed to differences between that noise and the soft tissue displacements that are actually occurring.
Collapse
Affiliation(s)
- Alana Peters
- Royal Children's Hospital, 52 Flemington Road, Parkville, Victoria 3052, Australia.
| | | | | | | |
Collapse
|
18
|
Sangeux M, Peters A, Baker R. Hip joint centre localization: Evaluation on normal subjects in the context of gait analysis. Gait Posture 2011; 34:324-8. [PMID: 21715169 DOI: 10.1016/j.gaitpost.2011.05.019] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2010] [Revised: 05/19/2011] [Accepted: 05/23/2011] [Indexed: 02/02/2023]
Abstract
Locating the position of the hip joint centre (HJC) is an important part of lower limb modeling for gait analysis. Regression equations have been used in the past but a range of functional calibration methods are now available. This study compared the accuracy of HJC localization from two sets of regression equations and five different functional calibration methods against three dimensional ultrasound (3-DUS) on a population of 19 able bodied subjects. Results show that the geometric sphere fitting technique was the best performer with mean absolute distance error of 15mm and 85% of measurements being within 20mm. The results also show that widely used regression equations perform particularly badly whereas the most recent equations performed very closely to the best functional method with a mean absolute error of 16mm and 88% of measurements being within 20mm. In vivo results are more than an order of magnitude worse than predictions using synthetic data suggesting that additional work is required before soft tissue artifact can be effectively modelled.
Collapse
Affiliation(s)
- Morgan Sangeux
- Hugh Williamson Gait Analysis Laboratory, Royal Children's Hospital, Flemington Rd, Parkville 3052, Australia.
| | | | | |
Collapse
|
19
|
Ehrig RM, Heller MO, Kratzenstein S, Duda GN, Trepczynski A, Taylor WR. The SCoRE residual: A quality index to assess the accuracy of joint estimations. J Biomech 2011; 44:1400-4. [DOI: 10.1016/j.jbiomech.2010.12.009] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Revised: 12/08/2010] [Accepted: 12/08/2010] [Indexed: 11/26/2022]
|