1
|
Zhang J, Yao X, Song Y, Yin P. Establishment and preliminary evaluation of CT-based classification for distal radius fracture. Sci Rep 2024; 14:9673. [PMID: 38671052 PMCID: PMC11053106 DOI: 10.1038/s41598-024-60416-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Accepted: 04/23/2024] [Indexed: 04/28/2024] Open
Abstract
Establish a new classification system of distal radius fracture based on computed tomographic (CT), and evaluate its reliability and reproducibility preliminarily, and provide a new theoretical reference for clinicians to use the clinical classification system. The imaging data and clinical data of 204 inpatients with distal radius fracture during 6 years from January 1, 2014 to January 1, 2019 in orthopaedic department were analyzed retrospectively and classified based on CT. Three observers evaluated the image data of 48 randomly selected cases based on CT at different time nodes of T1 and T2. Cohen's kappa was used to calculate the consistency. At the last follow-up, patients' Disabilities of the Arm, Shoulder and Hand (DASH), Patient Rated Wrist Evaluation (PRWE), and VAS scores were collected. Among 204 cases, there were 12 cases of type 1, including 6 cases of type 1-D, 4 cases of type 1-V and 2 cases of type 1-R. There were 6 cases of type 2, including 2 cases of type 2-DV, 2 cases of type 2-DR and 2 cases of type 2-VR. There were 186 cases of type 3, including 32 cases of type 3-0, 127 cases of type 3-1 and 27 cases of type 3-2. There was no significant difference in DASH, PRWE and VAS scores among all types (P > 0.05). The results of interobserver reproducibility were kappa = 0.985, ICC = 0.984 in the first evaluation, kappa = 0.986, ICC = 0.986 in the second evaluation. The results of intraobserver reproducibility were O1 = 0.991, O2 = 0.991, O3 = 0.989 respectively. The new classification system of distal radius fracture based on CT has theoretical and practical significance for incision selection, fracture reduction and internal fixation. 123 classification system is clear, comprehensive, easy to understand and remember. Moreover, it has higher interobserver reliability and intraobserver reproducibility than other systems reported at present.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Orthopaedics, The Affiliated Hospital of Innermongolia Medical University, Hohhot, 010010, China.
- Department of Orthopaedics, Chinese People's Liberation Army General Hospital (301 Hospital), Beijing, 100038, China.
| | - Xiaoke Yao
- Department of Orthopedics, Chengdu First People's Hospital, Chengdu, 610041, Sichuan, China
| | - Yanan Song
- National Engineering Laboratory for Medical Big Data Application Technology, Chinese People's Liberation Army General Hospital, Beijing, 100853, China
| | - Peng Yin
- Department of Orthopaedics, Beijing Chao-Yang Hospital, China Capital Medical University, Beijing, 100020, China.
| |
Collapse
|
2
|
Longo UG, De Salvatore S, Mazzola A, Salvatore G, Mera BJ, Piergentili I, Denaro V. Colles' Fracture: An Epidemiological Nationwide Study in Italy from 2001 to 2016. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3956. [PMID: 36900966 PMCID: PMC10002201 DOI: 10.3390/ijerph20053956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/19/2023] [Accepted: 02/20/2023] [Indexed: 06/18/2023]
Abstract
The present study aimed to evaluate the yearly number of Colles' fractures in Italy from 2001 to 2016, based on official information found in hospitalization records. A secondary aim was to estimate the average length of hospitalization for patients with a Colles' fracture. A tertiary aim was to investigate the distribution of the procedures generally performed for Colles' fractures' treatment in Italy. An analysis of the National Hospital Discharge records (SDO) maintained at the Italian Ministry of Health, concerning the 15 years of our study (from 2001 to 2016) was performed. Data are anonymous and include the patient's age, sex, domicile, length of hospital stays (days), primary diagnoses and primary procedures. From 2001 to 2016, 120,932 procedures for Colles' fracture were performed in Italy, which represented an incidence of 14.8 procedures for every 100,000 adult Italian inhabitants. The main number of surgeries was found in the 65-69- and 70-74-year age groups. In the present study, we review the epidemiology of Colles' fractures in the Italian population, the burden of the disease on the national health care system (in terms of length of hospitalization) and the distribution of the main surgical procedures performed for the treatment of the disease.
Collapse
Affiliation(s)
- Umile Giuseppe Longo
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| | - Sergio De Salvatore
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| | - Alessandro Mazzola
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| | - Giuseppe Salvatore
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| | - Barbara Juliette Mera
- School of Medicine, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Ilaria Piergentili
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| | - Vincenzo Denaro
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 200-00128 Roma, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 21-00128 Roma, Italy
| |
Collapse
|
3
|
Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system. Sci Rep 2021; 11:20176. [PMID: 34635787 PMCID: PMC8505435 DOI: 10.1038/s41598-021-99748-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 09/22/2021] [Indexed: 11/09/2022] Open
Abstract
Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current-time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FDUr77 and LDUr77 examinations (p < 0.001) with LDUr77 scans also providing favorable bone visualization compared to FDBr69 and FDBr62 (p < 0.001). Fleiss' kappa was 0.618 (0.594-0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.
Collapse
|
4
|
Neder Filho AT, Mazzer N, Bataglion LR, Pires RE, Macedo AP, Shimano AC. Distal radius fracture fixation using volar plate: A comparative study evaluating the biomechanical behavior of uni and bicortical distal screws. Injury 2021; 52 Suppl 3:S38-S43. [PMID: 34172266 DOI: 10.1016/j.injury.2021.02.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/09/2021] [Accepted: 02/11/2021] [Indexed: 02/02/2023]
Abstract
Extensor tendon ruptures caused by bicortical screws impingement following distal radius fracture fixation with volar plates are extensively reported in the literature. Thus, a biomechanical study comparing unicortical and bicortical fixations in intra-articular distal radius fracture models is critical in decision-making regarding distal radius fracture management. Forty-two synthetic radius models were fixed using a variable angle volar distal locking plate with seven screws. They were divided into 6 groups (n = 7): G1/G3/G4 unicortical fixation (75% of anteroposterior distal radius lenght); G2/G4/G6 bicortical fixation. Each group underwent a different mechanical test: axial compression (G1/G2), dorsal flexion (G3/G4), and volar flexion (G5/G6). The load application rate was 5 mm/min and 1000 cycles of 50 to 250 N at 1 Hz were performed between both static tests. Comparative results in the first static test, in the second static test, and in failure generally showed a very similar behavior. Models depicted similar behavior in the second static test when cyclic load was performed. Therefore, one can realize that stiffness differed during dorsal flexion only in the first static test. Maximum force to break the model in axial compression was greater in bicortical than in unicortical construct. Since biomechanical properties are similar, we recommend using unicortical distal locking screws in distal radius fracture fixation with volar plates to prevent extensor tendon ruptures.
Collapse
Affiliation(s)
- Antonio Tufi Neder Filho
- Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo. Ribeirão Preto SP, Brazil.
| | - Nilton Mazzer
- Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo. Ribeirão Preto SP, Brazil
| | - Leonardo Rigobello Bataglion
- Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo. Ribeirão Preto SP, Brazil
| | - Robinson Esteves Pires
- Departamento do Aparelho Locomotor, Faculdade de Medicina da Universidade Federal de Minas Gerais. Belo Horizonte MG, Brazil
| | - Ana Paula Macedo
- Departamento de Materiais Dentários e Próteses, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo. Ribeirão Preto SP, Brazil
| | - Antonio Carlos Shimano
- Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo. Ribeirão Preto SP, Brazil
| |
Collapse
|
5
|
Adenikinju A, Ranson R, Rettig SA, Egol KA, Konda SR. Ability of a Risk Prediction Tool to Stratify Quality and Cost for Older Patients With Operative Distal Radius Fractures. Geriatr Orthop Surg Rehabil 2021; 12:2151459321999634. [PMID: 33786205 PMCID: PMC7961699 DOI: 10.1177/2151459321999634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 01/17/2021] [Accepted: 02/09/2021] [Indexed: 11/30/2022] Open
Abstract
Introduction: Distal radius fractures are the second most common fracture in the elderly population. The incidence of these fractures has increased over time, and is projected to continue to do so. The aim of this study is to utilize a validated trauma risk prediction tool to stratify middle-aged and geriatric patients with operative distal radius fractures as well as compare hospital quality metrics and inpatient hospitalization costs among the risk groups. Materials and Methods: Patients were prospectively enrolled in an orthopedic trauma registry. The Score for Trauma Triage in Geriatric and Middle Aged (STTGMA) was calculated using patient demographics, injury severity, and functional status. Patients were then stratified into minimal-risk, moderate-risk, and high-risk cohorts based on their scores. Length of stay, need for escalation of care, complications, mortality, discharge location, 1-year patient reported outcomes, and index admission costs were evaluated. Results: Ninety-two patients met inclusion criteria. Sixty-three (68.5%) patients were managed with outpatient surgery. The mean inpatient length of stay for the high-risk cohort was 2.9x and 2.2x higher than the minimal and moderate-risk cohorts, respectively (2.0 + 2.9 days vs. 0.7 + 0.9 and 0.9 + 1.1 days, P = .019). There were no complications or mortality in any of the risk groups. No patients required intensive care and all patients were discharged home. There was no difference in readmission rates, inpatient cost, or 1-year patient reported outcomes among the risk cohorts. Discussion/Conclusions: The Score for Trauma Triage in Geriatric and Middle-Aged is able to risk-stratify patients that undergo operative intervention of distal radius fractures. Middle aged and elderly patients with isolated closed distal radius fractures can be safely managed on an outpatient basis regardless of risk. Standardized pathways can be created in the management of these injuries, thereby optimizing value-based care. Level of evidence: Prognostic Level III
Collapse
Affiliation(s)
- Abidemi Adenikinju
- Department of Orthopedics, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY, USA
| | - Rachel Ranson
- Department of Orthopedics, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY, USA
| | - Samantha A Rettig
- Department of Orthopedics, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY, USA
| | - Kenneth A Egol
- Department of Orthopedics, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY, USA.,Department of Orthopedics, Jamaica Hospital Medical Center, Medisys Health Network, Queens, NY, USA
| | - Sanjit R Konda
- Department of Orthopedics, NYU Langone Orthopedic Hospital, NYU Langone Health, New York, NY, USA.,Department of Orthopedics, Jamaica Hospital Medical Center, Medisys Health Network, Queens, NY, USA
| |
Collapse
|
6
|
Nagai T, Tanimoto K, Tomizuka Y, Uei H, Nagaoka M. Nutrition status and functional prognosis among elderly patients with distal radius fracture: a retrospective cohort study. J Orthop Surg Res 2020; 15:133. [PMID: 32264913 PMCID: PMC7140562 DOI: 10.1186/s13018-020-01657-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 03/27/2020] [Indexed: 11/16/2022] Open
Abstract
Background Distal radius fractures (DRF) are common in the elderly and are typically caused falls. Malnutrition has also been identified as a poor prognostic factor in elderly patients with fractures. However, the relationship between nutritional status and subsequent falls and functional prognosis for DRF in the elderly is not clear. The aim of the present study was to investigate the association between nutritional status and functional prognosis in elderly patients with DRF. Methods Study participants included 229 outpatients who required surgical treatment for DRF. The patients’ clinical information, including age, sex, body mass index, bone mineral density, geriatric nnutritional risk index (GNRI), total number of drugs being treated with on admission, use of drugs for osteoporosis, comorbidity severity, the Barthel Index (BI), presence of subsequent falls, fracture type, postoperative follow-up period, and Mayo wrist score was reviewed. Subjects were further divided into two groups according to their GNRI: the malnutrition group and the normal group. Propensity score matching was used to confirm factors affecting the BI and subsequent falls. Results Thirty-one patients (13.5%) presented with malnutrition before surgery for DRF. According to multiple liner regression analysis, the GNRI positively affected the efficiency of the BI (β = 0.392, 95% confidence interval [CI], 0.001 to 0.351, p = 0.039). Furthermore, on logistic regression analysis, subsequent falls were associated with serum albumin levels (odds ratio = 0.033, 95% CI, 0.002 to 0.477, p = 0.012). Conclusion Malnutrition impaired improvement of activities of daily living (ADL) and increased the incidence of subsequent falls. Improvement of nutritional status before DRF surgery may further improve ADL and prevent falls.
Collapse
Affiliation(s)
- Takako Nagai
- Department of Rehabilitation Medicine, Nihon University Hospital, 1-6 Kandasurugadai, Chiyoda-ku, Tokyo, 1018309, Japan. .,Department of Orthopedic Surgery, Osumi Hospital, Tokyo, Japan.
| | - Koji Tanimoto
- Department of Orthopedic Surgery, Nihon University Hospital, Tokyo, Japan
| | - Yoshiaki Tomizuka
- Department of Orthopedic Surgery, Nihon University Hospital, Tokyo, Japan
| | - Hiroshi Uei
- Department of Orthopedic Surgery, Nihon University Hospital, Tokyo, Japan
| | - Masahiro Nagaoka
- Department of Orthopedic Surgery, Nihon University Hospital, Tokyo, Japan
| |
Collapse
|
7
|
Cui X, Liang L, Zhang H, Li Y, Cheng H, Liu G, Cheng Y, Du Y, Liu J, Wang Z, Tian Y. The effectiveness and safety of plaster splint and splints for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Medicine (Baltimore) 2020; 99:e19211. [PMID: 32118722 PMCID: PMC7478763 DOI: 10.1097/md.0000000000019211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND To assess the efficacy and safety of plaster splint vs splints in the treatment of distal radius fractures (DRFs). METHODS For a more comprehensive collection of original study, we mainly searched 9 electronic databases including the PubMed, Web of Science, EMBASE, Cochrane Library, Cochrane Central Register of Controlled Trials (CENTRAL), Clinical Trials.gov, the Chinese National Knowledge Infrastructure Database (CNKI), Wanfang Database, and VIP Database. The retrieval date of all databases is from the establishment to January 2019. In the aspect of assessing the quality of original research methodology, we mainly rely on the Cochrane risk bias assessment tool and GRADE assessment method. Revman 5.3 is used for statistical analysis. RESULTS A total of 8 studies involving 717 participants were included. The results showed that effective rate (RR = 0.99, 95%CI 0.91 to 1.07, P = .83), reduction rate (RR = 1.00, 95%CI 0.93 to 1.07, P = .98), and complication rate of the plaster splint had no significant difference with the splint. In addition, for the excellent rate of treatment, subgroup analysis based on the included studies found that when the intervention period was 4 weeks, the plaster splint was better than the splint, and when the intervention period was more than 4 weeks, there was no significant difference between them. CONCLUSIONS There is no sufficient evidence that plaster splint is superior to splint. However, according to current evidence, plaster splint is more effective than splint when the intervention period is shorter (4 weeks), and its advantage disappears when the intervention period is longer (> 4 weeks). It should be noted that the results of this study were influenced by the sample size and the quality of the included studies. More high-quality and well-controlled RCTs are needed to draw better conclusions in further study.
Collapse
Affiliation(s)
- Xin Cui
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Long Liang
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Hongyan Zhang
- Guangzhou University of Traditional Chinese Medicine, Guangzhou
| | - Yongyao Li
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Hao Cheng
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Guangwei Liu
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Yongzhong Cheng
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Yachao Du
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| | - Jiani Liu
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Zhibo Wang
- Xiyuan Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Yaliang Tian
- Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing
| |
Collapse
|
8
|
Caruso G, Tonon F, Gildone A, Andreotti M, Altavilla R, Valentini A, Valpiani G, Massari L. Below-elbow or above-elbow cast for conservative treatment of extra-articular distal radius fractures with dorsal displacement: a prospective randomized trial. J Orthop Surg Res 2019; 14:477. [PMID: 31888682 PMCID: PMC6937655 DOI: 10.1186/s13018-019-1530-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 12/19/2019] [Indexed: 01/05/2023] Open
Abstract
Background Distal radial fractures are common traumatic injuries, but their management remains controversial also in case of conservative treatment regarding the type of immobilisation. Hence, we conducted a two-arm, parallel-group, prospective randomised trial to compare the capacity of long casts (above-elbow) and short casts (below-elbow) to maintain the reduction of extra-articular distal radius fractures with dorsal displacement (AO/OTA classification: 2R3A2.2). Methods Seventy-four eligible patients with AO/OTA 2R3A2.2 fractures treated with closed reduction and cast immobilisation were randomised to the long cast group (n°= 37) or to the short cast group (n°= 37). Baseline radiological parameters, radial inclination (RI), radial height (RH), ulnar variance (UV) and palmar tilt (PT) were taken, and compared with clinical (DASH, Mayo Wrist and Mayo Elbow) and radiological scores taken at 7–10 days, 4 weeks and 12 weeks. Furthermore, to evaluate correlations between radiological parameters and functional outcomes, patients were divided into two groups according to whether or not their radiological parameters at Follow-ups 2 and 3 were acceptable, i.e. within the range 11–12 mm for RH, 16°–28° for RI, − 4–+ 2 mm for UV and 0°–22° for PT. Results Patient demographic and baseline radiological parameters were similar between groups. At follow-up, there were no statistically significant differences between the two types of cast in terms of RI, RH, UV or PT, or Mayo wrist or DASH scores. Short cast group patients displayed better Mayo elbow score at follow-up 2 (4 weeks), but this difference was no longer statistically significant at follow-up 3 (12 weeks). No statistically significant differences in clinical outcomes were found between patients who presented acceptable radiographic parameters at follow-up and those who did not. Conclusion As there were no significant differences between short casts and long casts in terms of fracture reduction maintenance or clinical outcomes, short casts are an effective method of post-reduction immobilisation in AO/OTA 2R3A2.2 fracture of the radius. Radiological parameters outside the range conventionally considered acceptable do not preclude a satisfactory clinical outcome. Trial registration ClinicalTrials.gov PRS, NCT04062110. Registred 20 August 2019.
Collapse
Affiliation(s)
- Gaetano Caruso
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy. .,Department of Biomedical and Speciality Surgical Sciences, University of Ferrara, Via Luigi Borsari 46, 44121, Ferrara, Italy.
| | - Francesco Tonon
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy.,Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Via Luigi Borsari 46, 44121, Ferrara, Italy
| | - Alessandro Gildone
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy
| | - Mattia Andreotti
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy.,Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Via Luigi Borsari 46, 44121, Ferrara, Italy
| | - Roberto Altavilla
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy
| | - Alessandra Valentini
- Department of Statistics, University of Bologna, Via Zamboni 33, 40126, Bologna, Italy
| | - Giorgia Valpiani
- Research Innovation Quality and Accreditation Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy
| | - Leo Massari
- Orthopedic and Traumatology Unit, Sant'Anna University Hospital of Ferrara, Via Aldo Moro 8, 44124 Cona, Ferrara, Italy.,Department of Biomedical and Speciality Surgical Sciences, University of Ferrara, Via Luigi Borsari 46, 44121, Ferrara, Italy
| |
Collapse
|
9
|
Yazdanshenas H, Washington ER, Madadi F, Madadi F, Shamie AN, Hornicek FJ, Azari K. Introducing and Prospective Efficacy Comparison of an Innovative and Affordable Technique for the Treatment of Distal Radius Fractures. J Orthop 2019; 16:596-602. [PMID: 31708608 DOI: 10.1016/j.jor.2019.05.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Accepted: 05/26/2019] [Indexed: 12/24/2022] Open
Abstract
Background There are different treatments as well as controversies surrounding the adequate treatment for Distal Radius Fractures (DRF). In the absence of enough evidence[HYPHEN]base data regarding clinical effectiveness of available treatments, cost should be considered as an essential factor in selecting the surgical technique for DRF treatment. The goal of this study is introducing an improved and modified pin[HYPHEN]and[HYPHEN]plaster (MP&P) technique as an affordable alternative for treatment of DRF. This study also assesses and compares the outcomes of DRF treatment by using the introduced method versus external fixation (EF) technique. Methods In this clinical cohort study, 98 patients presenting with closed DRF Types III or IV, randomly were classified into two modified P&P (50 patients) and EF (48 patients) groups and assessed for functional, clinical, radiographic and overall outcome at the time, 2, 10 and 22 months after surgery. They were also followed[HYPHEN]up for up to 3 years to determine the rate of complications. Results Eighty one percent of EF and 86% of MP&P group were female. The average ages in the EF and MP&P groups were 44.9 ± 12.4 and 46.1 ± 5.4, respectively. Around 70% of the patients in each group had a Type III fracture, and 30% had Type IV. The rate of complications was higher among EF group patients (seven major and seven minor complications) compared to the MP&P (only 4 minor complications), however the difference between two groups regarding the complications and treatment outcome were insignificant, except in extension ROM and the quick[HYPHEN]dash score (only in two and four months follow up visits) and also returning to work (only in two month follow up visit). Conclusion This study introduces a modified P&P technique that protects the transverse palmar curvature, prevents the collapse of the distal radius, and simplifies casting, thereby obviating a full arm cast and mitigating elbow stiffness in patient outcomes. This modified technique could be considered as a more cost[HYPHEN]conscious alternative to external fixation for patients with distal radius fractures.
Collapse
Affiliation(s)
- Hamed Yazdanshenas
- Department of Orthopedic Surgery, Charles R. Drew University of Medicine and Science, Los Angeles, CA, USA.,Department of Orthopedic Surgery, University of California, Los Angeles (UCLA), Los Angeles, CA, USA.,Department of Family Medicine, University of California, Los Angeles (UCLA), Los Angeles, CA, USA.,Department of Family Medicine Charles R. Drew University of Medicine and Science, Los Angeles, CA, USA
| | - Eleby Rudolph Washington
- Department of Orthopedic Surgery, Charles R. Drew University of Medicine and Science, Los Angeles, CA, USA.,Department of Orthopedic Surgery, University of California, Los Angeles (UCLA), Los Angeles, CA, USA
| | - Firoozeh Madadi
- Department of Anesthesiology, Shahid Beheshti University of Medicine and Science, Tehran, Iran
| | - Firooz Madadi
- Department of Orthopedic Surgery, Shahid Beheshti University of Medicine and Science, Tehran, Iran
| | - Arya Nick Shamie
- Department of Orthopedic Surgery, University of California, Los Angeles (UCLA), Los Angeles, CA, USA
| | - Francis John Hornicek
- Department of Orthopedic Surgery, University of California, Los Angeles (UCLA), Los Angeles, CA, USA
| | - Kodi Azari
- Department of Orthopedic Surgery, University of California, Los Angeles (UCLA), Los Angeles, CA, USA
| |
Collapse
|
10
|
Raudasoja L, Vastamäki H, Raatikainen T. The importance of radiological results in distal radius fracture operations: Functional outcome after long-term (6.5 years) follow-up. SAGE Open Med 2018. [PMID: 29854401 DOI: 10.1177/2050312118776578.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background and Aims Whether or not radiological results correlate with functional outcome after operative treatment of distal radius fractures still remains controversial. We carried out a retrospective study to analyse the long-term (6.5 year) outcome of radius fractures treated by means of surgery in our hospital. The aim of the study was to explore whether step-off on radius joint surface, shortening of the radius versus ulnar height and dorsal or volar tilt of the radius correlate with long-term Patient-Rated Wrist Evaluation or Quick Disability of the Arm, Shoulder and Hand scores among 100 consecutive patients after surgical treatment. Materials and Methods Of these, 60 patients (63 wrists) participated. They were examined radiologically, clinically and by means of a questionnaire. Results Shortening of the radius correlated significantly with both Patient-Rated Wrist Evaluation and Quick Disability of the Arm, Shoulder and Hand scores. Step-off on the radius joint surface correlated significantly with worse PRWE scores, with no difference in Quick Disability of the Arm, Shoulder and Hand evaluation. Dorsal or volar tilt showed no statistical correlation (though it was mild in this group). The age of the patients (below 60 years vs 60 years or above) did not affect the PRWE or Quick Disability of the Arm, Shoulder and Hand results. Conclusion Our results indicate that when it comes to conserving the radial height and congruence of the joint surface, the more precise the reduction of the fracture achieved by surgical means, the better the functional outcome.
Collapse
Affiliation(s)
- L Raudasoja
- Department of Musculoskeletal and Plastic Surgery, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - H Vastamäki
- Orton Research Institute, Orton Foundation, Helsinki, Finland
| | - T Raatikainen
- Department of Musculoskeletal and Plastic Surgery, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
11
|
Raudasoja L, Vastamäki H, Raatikainen T. The importance of radiological results in distal radius fracture operations: Functional outcome after long-term (6.5 years) follow-up. SAGE Open Med 2018; 6:2050312118776578. [PMID: 29854401 PMCID: PMC5968661 DOI: 10.1177/2050312118776578] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Accepted: 04/18/2018] [Indexed: 01/30/2023] Open
Abstract
Background and Aims: Whether or not radiological results correlate with functional outcome after operative treatment of distal radius fractures still remains controversial. We carried out a retrospective study to analyse the long-term (6.5 year) outcome of radius fractures treated by means of surgery in our hospital. The aim of the study was to explore whether step-off on radius joint surface, shortening of the radius versus ulnar height and dorsal or volar tilt of the radius correlate with long-term Patient-Rated Wrist Evaluation or Quick Disability of the Arm, Shoulder and Hand scores among 100 consecutive patients after surgical treatment. Materials and Methods: Of these, 60 patients (63 wrists) participated. They were examined radiologically, clinically and by means of a questionnaire. Results: Shortening of the radius correlated significantly with both Patient-Rated Wrist Evaluation and Quick Disability of the Arm, Shoulder and Hand scores. Step-off on the radius joint surface correlated significantly with worse PRWE scores, with no difference in Quick Disability of the Arm, Shoulder and Hand evaluation. Dorsal or volar tilt showed no statistical correlation (though it was mild in this group). The age of the patients (below 60 years vs 60 years or above) did not affect the PRWE or Quick Disability of the Arm, Shoulder and Hand results. Conclusion: Our results indicate that when it comes to conserving the radial height and congruence of the joint surface, the more precise the reduction of the fracture achieved by surgical means, the better the functional outcome.
Collapse
Affiliation(s)
- L Raudasoja
- Department of Musculoskeletal and Plastic Surgery, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - H Vastamäki
- Orton Research Institute, Orton Foundation, Helsinki, Finland
| | - T Raatikainen
- Department of Musculoskeletal and Plastic Surgery, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
12
|
Synek A, Borgmann L, Traxler H, Huf W, Euler E, Chevalier Y, Baumbach SF. Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study. BMC Musculoskelet Disord 2016; 17:120. [PMID: 26966085 PMCID: PMC4785720 DOI: 10.1186/s12891-016-0972-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 03/03/2016] [Indexed: 11/30/2022] Open
Abstract
Background Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperative distal screw length determination, and (2) sufficient primary biomechanical stability of SDLS compared to standard locking screws (SLS). Methods We first assessed the feasibility of preoperative screw length determination (1): Distal radius width, depth and distal screw lengths were measured in 38 human radii. Correlations between distal radius width and depth were assessed, a cluster analysis (Ward’s method and squared Euclidean distance) for distal radius width conducted, and intra-cluster screw lengths analyzed (ANOVA). The biomechanical performance of SDLS (2) was assessed by comparison to SLS in a distal radius fracture model (AO-23 A3). 75 % distal screw length was chosen for both groups to simulate a worst-case scenario. Uniaxial compression tests were conducted to measure stiffness, elastic limit, maximum force and residual tilt. Statistics comprised of independent sample t-tests and a Bonferroni correction (p < 0.0125). Results (1) Distal radius width and depth showed a high correlation (R2 = 0.79; p < 0.001). Three distal radius width clusters could be identified: small <34 mm; medium 34–36.9 mm; large >36.9 mm. ANOVA and Tukey post-hoc analysis revealed significantly different volar-dorsal depths (p < 0.05) for nearly all screws. (2) To assess biomechanical stability nine specimens were tested each; no significant differences were found between the SDLS and SLS groups. Conclusions This feasibility study demonstrates that (1) distal radius width can be used as a predictor for distal screw length and (2) that SDLS provides mechanical stability equivalent to SLS. These results highlight the feasibility of applying SDLS screws in volar plate osteosynthesis at least in extraarticular fractures.
Collapse
Affiliation(s)
- Alexaner Synek
- Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria
| | - Lars Borgmann
- Center for Higher Education, TU Dortmund University, Dortmund, Germany
| | - Hannes Traxler
- Center of Anatomy and Cell Biology, Department of Systematic Anatomy, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Huf
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Ekkehard Euler
- Department of Trauma Surgery, Campus Innenstadt, Ludwig-Maximilians-University, Nussbaumstrasse 20, 80336, Munich, Germany
| | - Yan Chevalier
- Department of Orthopedic Surgery, Laboratory for Biomechanics and Experimental Orthopedics, Campus Grosshadern, Ludwig-Maximilians-University, Munich, Germany
| | - Sebastian F Baumbach
- Department of Trauma Surgery, Campus Innenstadt, Ludwig-Maximilians-University, Nussbaumstrasse 20, 80336, Munich, Germany.
| |
Collapse
|
13
|
Fracture of the distal radius: epidemiology and premanagement radiographic characterization. AJR Am J Roentgenol 2014; 203:551-9. [PMID: 25148157 DOI: 10.2214/ajr.13.12140] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE Fractures of the distal radius are common and frequently encountered by the radiologist. We review the epidemiology, classification, as well as the concept of instability. Salient qualitative and quantitative features of the distal radius fracture identifiable on the routine radiography series are highlighted. We conclude with a synopsis of descriptors that are of greatest utility to the clinician for treatment planning and that should be addressed in the radiology report. CONCLUSION A detailed understanding of the intricacies of the distal radius fracture is necessary for the radiologist to provide a clinically relevant description.
Collapse
|
14
|
Abstract
OBJECTIVE The purpose of this article is to describe the management options available for the treatment of the distal radius fracture as well as potential associated complications. CONCLUSION There are a wide variety of currently accepted and used treatment options for fractures of the distal radius, ranging from closed reduction with casting to various forms of invasive surgical management. The radiologist must be familiar with these various forms of management to recognize complications when present on follow-up radiographs.
Collapse
|