1
|
Wang X, Liang L, Giridharan GA, Sethu P, Wang Y, Qin KR, Qu P, Wang Y. Development of in vitro microfluidic models to study endothelial responses to pulsatility with different mechanical circulatory support devices. Analyst 2024; 149:3661-3672. [PMID: 38819086 DOI: 10.1039/d4an00507d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Continuous-flow ventricular assist devices (CFVAD) and counterpulsation devices (CPD) are used to treat heart failure (HF). CFVAD can diminish pulsatility, but pulsatile modes have been implemented to increase vascular pulsatility. The effects of CFVAD in a pulsatile mode and CPD support on the function of endothelial cells (ECs) are yet to be investigated. In this study, two in vitro microfluidic models for culturing ECs are proposed to reproduce blood pressure (BP) and wall shear stress (WSS) on the arterial endothelium while using these medical devices. The layout and parameters of the two microfluidic systems were optimized based on the principle of hemodynamic similarity to efficiently simulate physiological conditions. Moreover, the unique design of the double-pump and double afterload systems could successfully reproduce the working mode of CPDs in an in vitro microfluidic system. The performance of the two systems was verified by numerical simulations and in vitro experiments. BP and WSS under HF, CFVAD in pulsatile modes, and CPD were reproduced accurately in the systems, and these induced signals improved the expression of Ca2+, NO, and reactive oxygen species in ECs, proving that CPD may be effective in normalizing endothelial function and replacing CFVAD to a certain extent to treat non-severe HF. This method offers an important tool for the study of cell mechanobiology and a key experimental basis for exploring the potential value of mechanical circulatory support devices in reducing adverse events and improving outcomes in the treatment of HF in the future.
Collapse
Affiliation(s)
- Xueying Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Lixue Liang
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | | | - Palaniappan Sethu
- Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Yanxia Wang
- School of Rehabilitation Medicine, Shandong Second Medical University, Weifang 261053, Shandong Province, P. R. China
| | - Kai-Rong Qin
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| | - Peng Qu
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| | - Yu Wang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| |
Collapse
|
2
|
Liang L, Wang X, Chen D, Sethu P, Giridharan GA, Wang Y, Wang Y, Qin KR. Study on the hemodynamic effects of different pulsatile working modes of a rotary blood pump using a microfluidic platform that realizes in vitro cell culture effectively. LAB ON A CHIP 2024; 24:2428-2439. [PMID: 38625094 DOI: 10.1039/d4lc00159a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Rotary blood pumps (RBPs) operating at a constant speed generate non-physiologic blood pressure and flow rate, which can cause endothelial dysfunction, leading to adverse clinical events in peripheral blood vessels and other organs. Notably, pulsatile working modes of the RBP can increase vascular pulsatility to improve arterial endothelial function. However, the laws and related mechanisms of differentially regulating arterial endothelial function under different pulsatile working modes are still unclear. This knowledge gap hinders the optimal selection of the RBP working modes. To address these issues, this study developed a multi-element in vitro endothelial cell culture system (ECCS), which could realize in vitro cell culture effectively and accurately reproduce blood pressure, shear stress, and circumferential strain in the arterial endothelial microenvironment. Performance of this proposed ECCS was validated with numerical simulation and flow experiments. Subsequently, this study investigated the effects of four different pulsation frequency modes that change once every 1-4-fold cardiac cycles (80, 40, 80/3, and 20 cycles per min, respectively) of the RBP on the expression of nitric oxide (NO) and reactive oxygen species (ROS) in endothelial cells. Results indicated that the 2-fold and 3-fold cardiac cycles significantly increased the production of NO and prevented the excessive generation of ROS, potentially minimizing the occurrence of endothelial dysfunction and related adverse events during the RBP support, and were consistent with animal study findings. In general, this study may provide a scientific basis for the optimal selection of the RBP working modes and potential treatment options for heart failure.
Collapse
Affiliation(s)
- Lixue Liang
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Xueying Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Dong Chen
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Palaniappan Sethu
- Division of Cardiovascular Disease, Department of Medicine, School of Medicine and Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | | | - Yanxia Wang
- School of Rehabilitation Medicine, Shandong Second Medical University, Weifang 261053, Shandong Province, P. R. China
| | - Yu Wang
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| | - Kai-Rong Qin
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| |
Collapse
|
3
|
Tanaka S, Nishinaka T, Umeki A, Murakami T, Imaoka S, Mizuno T, Tsukiya T, Ono M. Hemodynamic Evaluation of Asynchronous Speed Modulation of a Continuous-Flow Left Ventricular Assist Device in an Acute-Myocardial Injury Sheep Model. Ann Biomed Eng 2024; 52:364-375. [PMID: 37851145 DOI: 10.1007/s10439-023-03383-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 10/09/2023] [Indexed: 10/19/2023]
Abstract
Asynchronous rotational-speed modulation of a continuous-flow left ventricular assist device (LVAD) can increase pulsatility; however, the feasibility of hemodynamic modification by asynchronous modulation of an LVAD has not been sufficiently verified. We evaluated the acute effect of an asynchronous-modulation mode under LVAD support and the accumulated effect of 6 consecutive hours of driving by the asynchronous-modulation mode on hemodynamics, including both ventricles, in a coronary microembolization-induced acute-myocardial injury sheep model. We evaluated 5-min LVAD-support hemodynamics, including biventricular parameters, by switching modes from constant-speed to asynchronous-modulation in the same animals ("acute-effect evaluation under LVAD support"). To determine the accumulated effect of a certain driving period, we evaluated hemodynamics including biventricular parameters after weaning from 6-hour (6 h) LVAD support by constant-speed or asynchronous-modulation mode ("6h-effect evaluation"). The acute-effect evaluation under LVAD support revealed that, compared to the constant-speed mode, the asynchronous-modulation mode increased vascular pulsatility but did not have significantly different effects on hemodynamics, including both ventricles. The 6 h-effect evaluation revealed that the hemodynamics did not differ significantly between the two groups except for some biventricular parameters which did not indicate negative effects of the asynchronous-modulation mode on both ventricles. The asynchronous-modulation mode could be feasible to increase vascular pulsatility without causing negative effects on hemodynamics including both ventricles. Compared to the constant-speed mode, the asynchronous-modulation mode increased pulsatility during LVAD support without negative effects on hemodynamics including both ventricles in the acute phase. Six hours of LVAD support with the asynchronous-modulation mode exerted no negative effects on hemodynamics, including both ventricles, after weaning from the LVAD.
Collapse
Affiliation(s)
- Shun Tanaka
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
| | - Tomohiro Nishinaka
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Akihide Umeki
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Takashi Murakami
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Shusuke Imaoka
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Toshihide Mizuno
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Tomonori Tsukiya
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan
| | - Minoru Ono
- Department of Cardiac Surgery, The University of Tokyo, 7-3-1, Hongo, Bunkyo , Tokyo, 113-8654, Japan
| |
Collapse
|
4
|
Huo M, Giridharan GA, Sethu P, Qu P, Qin K, Wang Y. Numerical simulation analysis of multi-scale computational fluid dynamics on hemodynamic parameters modulated by pulsatile working modes for the centrifugal and axial left ventricular assist devices. Comput Biol Med 2024; 169:107788. [PMID: 38091724 DOI: 10.1016/j.compbiomed.2023.107788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 11/08/2023] [Accepted: 11/28/2023] [Indexed: 02/08/2024]
Abstract
Continuous flow (CF) left ventricular assist devices (LVAD) operate at a constant speed mode, which could result in increased risk of adverse events due to reduced vascular pulsatility. Consequently, pump speed modulation algorithms have been proposed to augment vascular pulsatility. However, the quantitative local hemodynamic effects on the aorta when the pump is operating with speed modulation using different types of CF-LVADs are still under investigation. The computational fluid dynamics (CFD) study was conducted to quantitatively elucidate the hemodynamic effects on a clinical patient-specific aortic model under different speed patterns of CF-LVADs. Pressure distribution, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and velocity were calculated to compare their differences at constant and pulsatile speeds under centrifugal and axial LVAD support. Results showed that pulse pressure on the aorta was significantly larger under pulsatile speed mode than that under constant speed mode for both CF-LVADs, indicating enhanced aorta pulsatility, as well as the higher peak blood flow velocity on some representative slices of aorta. Pulsatile speed modulation enhanced peak WSS compared to constant speed; high TAWSS region appeared near the branch of left common carotid artery and distal aorta regardless of speed modes and CF-LVADs but these regions also had low OSI; RRT was almost the same for all the cases. This study may provide a basis for the scientific and reasonable selection of the pulsatile speed patterns of CF-LVADs for treating heart failure patients.
Collapse
Affiliation(s)
- Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | | | - Palaniappan Sethu
- Division of Cardiovascular Disease, Department of Medicine, School of Medicine and Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Peng Qu
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Kairong Qin
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Yu Wang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China.
| |
Collapse
|
5
|
Kuroda T, Miyagi C, Polakowski AR, Flick CR, Kuban BD, Fukamachi K, Karimov JH. Preservation of pulsatility with universal ventricular assist device: In vitro assessment for biventricular support. Artif Organs 2024; 48:182-190. [PMID: 37787082 DOI: 10.1111/aor.14656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 08/08/2023] [Accepted: 09/21/2023] [Indexed: 10/04/2023]
Abstract
BACKGROUND The objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop. METHODS Two UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility. RESULTS The aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support. CONCLUSIONS The UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Christine R Flick
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
6
|
Sahni A, Majee S, Pal JD, McIntyre EE, Cao K, Mukherjee D. Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.08.03.23292572. [PMID: 37609263 PMCID: PMC10441504 DOI: 10.1101/2023.08.03.23292572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Stroke remains a leading cause of complications and mortality in heart failure patients treated with LVAD circulatory support. Hemodynamics plays a central role in affecting risk and etiology of stroke during LVAD support. Yet, detailed quantitative assessment of hemodynamic variables and their relation to stroke outcomes in patients with an implanted LVAD remains a challenge. We present an in silico hemodynamics analysis in a set of 12 patients on LVAD support; 6 with reported stroke outcomes and 6 without. We conducted patient-specific hemodynamics simulations for models with the LVAD outflow graft reconstructed from cardiac-gated CT images. A pre-implantation baseline flow model was virtually generated for each case by removing the LVAD outflow graft and driving flow from the aortic root. Hemodynamics was characterized using quantitative descriptors for helical flow, vortex generation, and wall shear stress. Our analysis showed higher average values for descriptors of positive helical flow, vortex generation, and wall shear stress, across the 6 cases with stroke outcomes on LVAD support, when compared with cases without stroke. When the descriptors for LVAD-driven flow were compared against estimated baseline flow pre-implantation, extent of positive helicity was higher, and vorticity and wall shear were lower in cases with stroke compared to those without. The study suggests that quantitative analysis of hemodynamics after LVAD implantation; and hemodynamic alterations from a pre-implant flow scenario, can potentially reveal hidden information linked to stroke outcomes during LVAD support. This has broad implications on understanding stroke etiology, LVAD treatment planning, surgical optimization, and efficacy assessment.
Collapse
|
7
|
Sahni A, McIntyre EE, Cao K, Pal JD, Mukherjee D. The Relation Between Viscous Energy Dissipation and Pulsation for Aortic Hemodynamics Driven by a Left Ventricular Assist Device. Cardiovasc Eng Technol 2023; 14:560-576. [PMID: 37340092 DOI: 10.1007/s13239-023-00670-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 05/15/2023] [Indexed: 06/22/2023]
Abstract
Left ventricular assist device (LVAD) provides mechanical circulatory support for patients with advanced heart failure. Treatment using LVAD is commonly associated with complications such as stroke and gastro-intestinal bleeding. These complications are intimately related to the state of hemodynamics in the aorta, driven by a jet flow from the LVAD outflow graft that impinges into the aorta wall. Here we conduct a systematic analyses of hemodynamics driven by an LVAD with a specific focus on viscous energy transport and dissipation. We conduct a complementary set of analysis using idealized cylindrical tubes with diameter equivalent to common carotid artery and aorta, and a patient-specific model of 27 different LVAD configurations. Results from our analysis demonstrate how energy dissipation is governed by key parameters such as frequency and pulsation, wall elasticity, and LVAD outflow graft surgical anastomosis. We find that frequency, pulsation, and surgical angles have a dominant effect, while wall elasticity has a weaker effect, in determining the state of energy dissipation. For the patient-specific scenario, we also find that energy dissipation is higher in the aortic arch and lower in the abdominal aorta, when compared to the baseline flow without an LVAD. This further illustrates the key hemodynamic role played by the LVAD outflow jet impingement, and subsequent aortic hemodynamics during LVAD operation.
Collapse
Affiliation(s)
- Akshita Sahni
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| | - Erin E McIntyre
- Department of Surgery, University of Colorado, Anschutz Medical Campus, Aurora, USA
| | - Kelly Cao
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| | - Jay D Pal
- Department of Surgery, University of Washington, Seattle, USA
| | - Debanjan Mukherjee
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| |
Collapse
|
8
|
Tan Z, Huo M, Qin K, El-Baz AS, Sethu P, Wang Y, Giridharan GA. A sensorless, physiologic feedback control strategy to increase vascular pulsatility for rotary blood pumps. Biomed Signal Process Control 2023; 83:104640. [PMID: 36936779 PMCID: PMC10019090 DOI: 10.1016/j.bspc.2023.104640] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
Continuous flow rotary blood pumps (RBP) operating clinically at constant rotational speeds cannot match cardiac demand during varying physical activities, are susceptible to suction, diminish vascular pulsatility, and have an increased risk of adverse events. A sensorless, physiologic feedback control strategy for RBP was developed to mitigate these limitations. The proposed algorithm used intrinsic pump speed to obtain differential pump speed (ΔRPM). The proposed gain-scheduled proportional-integral controller, switching of setpoints between a higher pump speed differential setpoint (ΔRPM Hr ) and a lower pump speed differential setpoint (ΔRPM Lr ), generated pulsatility and physiologic perfusion, while avoiding suction. The switching between ΔRPM Hr and ΔRPM Lr setpoints occurred when the measured ΔRPM reached the pump differential reference setpoint. In-silico tests were implemented to assess the proposed algorithm during rest, exercise, a rapid 3-fold pulmonary vascular resistance increase, rapid change from exercise to rest, and compared with maintaining a constant pump speed setpoint. The proposed control algorithm augmented aortic pressure pulsatility to over 35 mmHg during rest and around 30 mmHg during exercise. Significantly, ventricular suction was avoided, and adequate cardiac output was maintained under all simulated conditions. The performance of the sensorless algorithm using estimation was similar to the performance of sensor-based method. This study demonstrated that augmentation of vascular pulsatility was feasible while avoiding ventricular suction and providing physiological pump outflows. Augmentation of vascular pulsatility can minimize adverse events that have been associated with diminished pulsatility. Mock circulation and animal studies would be conducted to validate these results.
Collapse
Affiliation(s)
- Zhehuan Tan
- School of Biomedical Engineering, Dalian University of Technology, Dalian, China
| | - Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Kairong Qin
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Ayman S El-Baz
- Department of Bioengineering, University of Louisville, Louisville, KY, USA
| | - Palaniappan Sethu
- Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Yu Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | | |
Collapse
|
9
|
Sahni A, McIntyre EE, Pal JD, Mukherjee D. Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation. Ann Biomed Eng 2023; 51:1226-1243. [PMID: 36705866 DOI: 10.1007/s10439-022-03127-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 12/25/2022] [Indexed: 01/28/2023]
Abstract
Left ventricular assist devices (LVADs) comprise a primary treatment choice for advanced heart failure patients. Treatment with LVAD is commonly associated with complications like stroke and gastro-intestinal (GI) bleeding, which adversely impacts treatment outcomes, and causes fatalities. The etiology and mechanisms of these complications can be linked to the fact that LVAD outflow jet leads to an altered state of hemodynamics in the aorta as compared to baseline flow driven by aortic jet during ventricular systole. Here, we present a framework for quantitative assessment of aortic hemodynamics in LVAD flows realistic human vasculature, with a focus on quantifying the differences between flow driven by LVAD jet and the physiological aortic jet when no LVAD is present. We model hemodynamics in the aortic arch proximal to the LVAD outflow graft, as well as in the abdominal aorta away from the LVAD region. We characterize hemodynamics using quantitative descriptors of flow velocity, stasis, helicity, vorticity and mixing, and wall shear stress. These are used on a set of 27 LVAD scenarios obtained by parametrically varying LVAD outflow graft anastomosis angles, and LVAD flow pulse modulation. Computed descriptors for each of these scenarios are compared against the baseline flow, and a detailed quantitative characterization of the altered state of hemodynamics due to LVAD operation (when compared to baseline aortic flow) is compiled. These are interpreted using a conceptual model for LVAD flow that distinguishes between flow originating from the LVAD outflow jet (and its impingement on the aorta wall), and flow originating from aortic jet during aortic valve opening in normal physiological state.
Collapse
Affiliation(s)
- Akshita Sahni
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| | - Erin E McIntyre
- Division of Cardiothoracic Surgery, University of Colorado, Anschutz Medical Campus, Aurora, USA
| | - Jay D Pal
- Department of Surgery, University of Washington, Seattle, USA
| | - Debanjan Mukherjee
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| |
Collapse
|
10
|
(Physiology of Continuous-flow Left Ventricular Assist Device Therapy. Translation of the document prepared by the Czech Society of Cardiology). COR ET VASA 2022. [DOI: 10.33678/cor.2022.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
11
|
Eisen HJ, Flack JM, Atluri P, Bansal N, Breathett K, Brown AL, Hankins SR, Khazanie P, Masri C, Pirlamarla P, Rowe T. Management of Hypertension in Patients With Ventricular Assist Devices: A Scientific Statement From the American Heart Association. Circ Heart Fail 2022; 15:e000074. [PMID: 35430896 DOI: 10.1161/hhf.0000000000000074] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Mechanical circulatory support with durable continuous-flow ventricular assist devices has become an important therapeutic management strategy for patients with advanced heart failure. As more patients have received these devices and the duration of support per patient has increased, the postimplantation complications have become more apparent, and the need for approaches to manage these complications has become more compelling. Continuous-flow ventricular assist devices, including axial-flow and centrifugal-flow pumps, are the most commonly used mechanical circulatory support devices. Continuous-flow ventricular assist devices and the native heart have a constant physiological interplay dependent on pump speed that affects pressure-flow relationships and patient hemodynamics. A major postimplantation complication is cerebrovascular vascular accidents. The causes of cerebrovascular vascular accidents in ventricular assist device recipients may be related to hypertension, thromboembolic events, bleeding from anticoagulation, or some combination of these. The most readily identifiable and preventable cause is hypertension. Hypertension management in these patients has been hampered by the fact that it is difficult to accurately measure blood pressure because these ventricular assist devices have continuous flow and are often not pulsatile. Mean arterial pressures have to be identified by Doppler or oscillometric cuff and treated. Although guidelines for hypertension management after ventricular assist device implantation are based largely on expert consensus and conventional wisdom, the mainstay of treatment for hypertension includes guideline-directed medical therapy for heart failure with reduced ejection fraction because this may reduce adverse effects associated with hypertension and increase the likelihood of favorable ventricular remodeling. The use of systemic anticoagulation in ventricular assist device recipients may at a given blood pressure increase the risk of stroke.
Collapse
|
12
|
Fresiello L, Najar A, Brynedal Ignell N, Zieliński K, Rocchi M, Meyns B, Perkins IL. Hemodynamic characterization of the Realheart® total artificial heart with a hybrid cardiovascular simulator. Artif Organs 2022; 46:1585-1596. [PMID: 35231138 DOI: 10.1111/aor.14223] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 12/28/2021] [Accepted: 02/18/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Heart failure is a growing health problem worldwide. Due to the lack of donor hearts there is a need for alternative therapies, such as total artificial hearts (TAHs). The aim of this study is to evaluate the hemodynamic performance of the Realheart® TAH, a new 4-chamber cardiac prosthesis device. METHODS The Realheart® TAH was connected to a hybrid cardiovascular simulator with inflow connections at left/right atrium, and outflow connections at the ascending aorta/pulmonary artery. The Realheart® TAH was tested at different pumping rates and stroke volumes. Different systemic resistances (20.0-16.7-13.3-10.0 Wood units), pulmonary resistances (6.7-3.3-1.7 Wood units), and pulmonary/systemic arterial compliances (1.4-0.6 mL/mmHg) were simulated. Tests were also conducted in static conditions, by imposing predefined values of preload-afterload across the artificial ventricle. RESULTS The Realheart® TAH allows the operator to finely tune the delivered flow by regulating the pumping rate and stroke volume of the artificial ventricles. For a systemic resistance of 16.7 Wood units the TAH flow ranges from 2.7±0.1 to 6.9±0.1 L/min. For a pulmonary resistance of 3.3 Wood units the TAH flow ranges from 3.1±0.0 to 8.2±0.3 L/min. The Realheart® TAH delivered a pulse pressure ranging between ~25 mmHg and ~50 mmHg for the tested conditions. CONCLUSIONS The Realheart® TAH offers great flexibility to adjust the output flow and delivers good pressure pulsatility in the vessels. A low sensitivity of device flow to the pressure drop across it was identified and a new version is under development to counteract this.
Collapse
Affiliation(s)
- Libera Fresiello
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.,Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Azad Najar
- R&D, Scandinavian Real Heart AB, Västerås, Sweden
| | | | - Krzysztof Zieliński
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Maria Rocchi
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Bart Meyns
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | | |
Collapse
|
13
|
Rosenbaum AN, Antaki JF, Behfar A, Villavicencio MA, Stulak J, Kushwaha SS. Physiology of Continuous-Flow Left Ventricular Assist Device Therapy. Compr Physiol 2021; 12:2731-2767. [PMID: 34964115 DOI: 10.1002/cphy.c210016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The expanding use of continuous-flow left ventricular assist devices (CF-LVADs) for end-stage heart failure warrants familiarity with the physiologic interaction of the device with the native circulation. Contemporary devices utilize predominantly centrifugal flow and, to a lesser extent, axial flow rotors that vary with respect to their intrinsic flow characteristics. Flow can be manipulated with adjustments to preload and afterload as in the native heart, and ascertainment of the predicted effects is provided by differential pressure-flow (H-Q) curves or loops. Valvular heart disease, especially aortic regurgitation, may significantly affect adequacy of mechanical support. In contrast, atrioventricular and ventriculoventricular timing is of less certain significance. Although beneficial effects of device therapy are typically seen due to enhanced distal perfusion, unloading of the left ventricle and atrium, and amelioration of secondary pulmonary hypertension, negative effects of CF-LVAD therapy on right ventricular filling and function, through right-sided loading and septal interaction, can make optimization challenging. Additionally, a lack of pulsatile energy provided by CF-LVAD therapy has physiologic consequences for end-organ function and may be responsible for a series of adverse effects. Rheological effects of intravascular pumps, especially shear stress exposure, result in platelet activation and hemolysis, which may result in both thrombotic and hemorrhagic consequences. Development of novel solutions for untoward device-circulatory interactions will facilitate hemodynamic support while mitigating adverse events. © 2021 American Physiological Society. Compr Physiol 12:1-37, 2021.
Collapse
Affiliation(s)
- Andrew N Rosenbaum
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Atta Behfar
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA.,VanCleve Cardiac Regenerative Medicine Program, Center for Regenerative Medicine, Mayo Clinic, Rochester, Minnesota, USA
| | | | - John Stulak
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Sudhir S Kushwaha
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
14
|
Wang Y, Wang J, Peng J, Huo M, Yang Z, Giridharan GA, Luan Y, Qin K. Effects of a Short-Term Left Ventricular Assist Device on Hemodynamics in a Heart Failure Patient-Specific Aorta Model: A CFD Study. Front Physiol 2021; 12:733464. [PMID: 34621186 PMCID: PMC8491745 DOI: 10.3389/fphys.2021.733464] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/20/2021] [Indexed: 11/24/2022] Open
Abstract
Patients with heart failure (HF) or undergoing cardiogenic shock and percutaneous coronary intervention require short-term cardiac support. Short-term cardiac support using a left ventricular assist device (LVAD) alters the pressure and flows of the vasculature by enhancing perfusion and improving the hemodynamic performance for the HF patients. However, due to the position of the inflow and outflow of the LVAD, the local hemodynamics within the aorta is altered with the LVAD support. Specifically, blood velocity, wall shear stress, and pressure difference are altered within the aorta. In this study, computational fluid dynamics (CFD) was used to elucidate the effects of a short-term LVAD for hemodynamic performance in a patient-specific aorta model. The three-dimensional (3D) geometric models of a patient-specific aorta and a short-term LVAD, Impella CP, were created. Velocity, wall shear stress, and pressure difference in the patient-specific aorta model with the Impella CP assistance were calculated and compared with the baseline values of the aorta without Impella CP support. Impella CP support augmented cardiac output, blood velocity, wall shear stress, and pressure difference in the aorta. The proposed CFD study could analyze the quantitative changes in the important hemodynamic parameters while considering the effects of Impella CP, and provide a scientific basis for further predicting and assessing the effects of these hemodynamic signals on the aorta.
Collapse
Affiliation(s)
- Yu Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Junwei Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Jing Peng
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Zhiqiang Yang
- Department of Cardiovascular Computed Tomography (CT) Examination, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | | | - Yong Luan
- Department of Anesthesiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Kairong Qin
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| |
Collapse
|
15
|
Netuka I, Pya Y, Poitier B, Ivak P, Konarik M, Perlès JC, Blažejová Z, Riha H, Bekbossynova M, Medressova A, Bousquet F, Latrémouille C, Jansen P. First Clinical Experience With the Pressure Sensor-Based Autoregulation of Blood Flow in an Artificial Heart. ASAIO J 2021; 67:1100-1108. [PMID: 34138778 PMCID: PMC8478302 DOI: 10.1097/mat.0000000000001485] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The CARMAT-Total Artificial Heart (C-TAH) is designed to provide heart replacement therapy for patients with end-stage biventricular failure. This report details the reliability and efficacy of the autoregulation device control mechanism (auto-mode), designed to mimic normal physiologic responses to changing patient needs. Hemodynamic data from a continuous cohort of 10 patients implanted with the device, recorded over 1,842 support days in auto-mode, were analyzed with respect to daily changing physiologic needs. The C-TAH uses embedded pressure sensors to regulate the pump output. Right and left ventricular outputs are automatically balanced. The operator sets target values and the inbuilt algorithm adjusts the stroke volume and beat rate, and hence cardiac output, automatically. Auto-mode is set perioperatively after initial postcardiopulmonary bypass hemodynamic stabilization. All patients showed a range of average inflow pressures of between 5 and 20 mm Hg during their daily activities, resulting in cardiac output responses of between 4.3 and 7.3 L/min. Operator adjustments were cumulatively only required on 20 occasions. This report demonstrates that the C-TAH auto-mode effectively produces appropriate physiologic responses reflective of changing patients' daily needs and represents one of the unique characteristics of this device in providing almost physiologic heart replacement therapy.
Collapse
Affiliation(s)
- Ivan Netuka
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Yuriy Pya
- National Research Cardiac Surgery Center (NRCSC), Nur-Sultan (Astana), Kazakhstan
| | | | - Peter Ivak
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Miroslav Konarik
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Jean-Christophe Perlès
- Carmat SA, Vélizy, France; and ¶Department of Anesthesiology and Intensive Care Medicine, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Zuzana Blažejová
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Hynek Riha
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Makhabbat Bekbossynova
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Assel Medressova
- From the Department of Cardiovascular Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Fabien Bousquet
- Carmat SA, Vélizy, France; and ¶Department of Anesthesiology and Intensive Care Medicine, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | | - Piet Jansen
- Carmat SA, Vélizy, France; and ¶Department of Anesthesiology and Intensive Care Medicine, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| |
Collapse
|
16
|
Torres DS, Mazzetto M, Cestari IA. A novel automated simulator of pediatric systemic circulation: Design and applications. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102926] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
17
|
Zhang Y, Zeng J, He X, Cao W, Peng X, Li G. Pulsatility protects the endothelial glycocalyx during extracorporeal membrane oxygenation. Microcirculation 2021; 28:e12722. [PMID: 34242445 DOI: 10.1111/micc.12722] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 05/03/2021] [Accepted: 07/05/2021] [Indexed: 01/06/2023]
Abstract
BACKGROUND Pulsatile flow protects vital organ function and improves microcirculatory perfusion during extracorporeal membrane oxygenation (ECMO). Studies revealed that pulsatile shear stress plays a vital role in microcirculatory function and integrity. The objective of this study was to investigate how pulsatility affects wall shear stress and endothelial glycocalyx components during ECMO. METHODS Using the i-Cor system, sixteen canine ECMO models were randomly allocated into the pulsatile or the non-pulsatile group (eight canines for each). Hemodynamic parameters, peak wall shear stress (PWSS), serum concentration of syndecan-1, and heparan sulfate were measured at different time points during ECMO. Pulsatile shear stress experiments were also performed in endothelial cells exposed to different magnitudes of pulsatility (five plates for each condition), with cell viability, the expressions of syndecan-1, and endothelial-to-mesenchymal transformation (EndMT) markers analyzed. RESULTS The pulsatile flow generated more surplus hemodynamic energy and preserved higher PWSS during ECMO. Serum concentrations of both syndecan-1 and heparan sulfate were negatively correlated with PWSS, and significantly lower levels were observed in the pulsatile group. Besides, non-pulsatility triggered EndMT and endothelial cells exposed to low pulsatility had the lowest possibility of EndMT. CONCLUSION The maintenance of the PWSS by pulsatility during ECMO possesses beneficial effects on glycocalyx integrity. Moreover, pulsatility prevents EndMT in endothelial cells, and low pulsatility exhibits the best protective effects. The augmentation of pulsatility may be a plausible future direction to improve the clinical outcome in ECMO.
Collapse
Affiliation(s)
- Yu Zhang
- Department of Pathology, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Jianfeng Zeng
- Department of Anesthesiology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Xiaoqian He
- Department of Obstetrics and Gynecology, Guangzhou Women and Children`s Medical Center, Guangzhou Medical University, Guangzhou, China
| | - Weidong Cao
- Department of Cardiothoracic Surgery, Dongguan People's Hospital, Affiliated Dongguan People's Hospital of Southern Medical University, Dongguan, China
| | - Xiaopeng Peng
- Department of Cardiothoracic Surgery, Dongguan People's Hospital, Affiliated Dongguan People's Hospital of Southern Medical University, Dongguan, China
| | - Guanhua Li
- Department of Cardiovascular Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| |
Collapse
|
18
|
Emmanuel S, Jansz P, Hayward C. How well do we understand pulsatility in the context of modern ventricular assist devices? Int J Artif Organs 2021; 44:923-929. [PMID: 33960234 DOI: 10.1177/03913988211012707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Modern ventricular assist devices (VADs) use a continuous flow design. It has been suggested that a lack of pulsatility contributes to a range of adverse outcomes including pump thrombus, gastrointestinal bleeding and stroke. To better assess the role of pulsatility in these adverse events, we first require a clear definition of 'pulsatility' in the setting of a severely impaired ventricle and a modern continuous flow VAD. METHODS A literature review was conducted to elucidate the understanding of pulsatility in modern VAD literature. Search engines used included PUBMED, EMBASE and the Cochrane library. Articles were appraised on three aspects: Whether they mentioned pulsatility; whether they mentioned which pulsatility measure was used and finally which methodology was used to obtain the value. RESULTS Of 354 articles reviewed, only 13 met our broad inclusion criteria. Of these articles, the most cited measure was pulsatility index (PI) - used by 11 of the publications. The methodology used to obtain the value was not uniform and five articles did not clearly state it. Other measures included pulse pressure and surplus haemodynamic energy. The majority of articles did not directly discuss pulsatility in the setting of patient-pump interaction. CONCLUSION Most publications did not provide a definition for pulsatility. In those that did, the most common measure was PI. Measuring PI was not standardised. Few papers addressed the impact of intrinsic ventricular function and arterial compliance on pulsatility. We suggest that future publications adopt a uniform definition which encompasses both patient and pump characteristics.
Collapse
Affiliation(s)
- Sam Emmanuel
- St Vincent's Hospital (Sydney), Darlinghurst, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, Australia.,School of Medicine, University of Notre Dame, Sydney, Australia.,Victor Chang Cardiac Research Institute, Sydney, Australia
| | - Paul Jansz
- St Vincent's Hospital (Sydney), Darlinghurst, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, Australia.,School of Medicine, University of Notre Dame, Sydney, Australia.,Victor Chang Cardiac Research Institute, Sydney, Australia
| | - Christopher Hayward
- St Vincent's Hospital (Sydney), Darlinghurst, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, Australia.,Victor Chang Cardiac Research Institute, Sydney, Australia
| |
Collapse
|
19
|
Kannojiya V, Das AK, Das PK. Comparative assessment of different versions of axial and centrifugal LVADs: A review. Artif Organs 2021; 45:665-681. [PMID: 33434332 DOI: 10.1111/aor.13914] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/18/2020] [Accepted: 01/04/2021] [Indexed: 02/06/2023]
Abstract
Continuous-flow left ventricular assist devices (LVADs) have gained tremendous acceptance for the treatment of end-stage heart failure patients. Among different versions, axial flow and centrifugal flow LVADs have shown remarkable potential for clinical implants. It is also very crucial to know which device serves its purpose better to treat heart failure patients. A thorough comparison of axial and centrifugal LVADs, which may guide doctors in deciding before the implant, still lacks in the literature. In this work, an assessment of axial and centrifugal LVADs has been made to suggest a better device by comparing their engineering, clinical, and technological development of design aspects. Hydrodynamic and hemodynamic aspects for both types of pumps are discussed along with their biocompatibility, bearing types, and sizes. It has been observed numerically that centrifugal LVADs perform better over axial LVADs in every engineering aspect like higher hydraulic efficiency, better characteristics curve, lesser power intake, and also lesser blood damage. However, the clinical outcomes suggest that centrifugal LVADs experience higher events of infections, renal, and respiratory dysfunction. In contrast, axial LVADs encountered higher bleeding and cardiac arrhythmia. Moreover, recent technological developments suggested that magnetic type bearings along with biocompatible coating improve the life of LVADs.
Collapse
Affiliation(s)
- Vikas Kannojiya
- Mechanical and Industrial Engineering Department, IIT Roorkee, Roorkee, India
| | - Arup Kumar Das
- Mechanical and Industrial Engineering Department, IIT Roorkee, Roorkee, India
| | | |
Collapse
|
20
|
Emmanuel S, Pearman M, Jansz P, Hayward CS. Vasoplegia in patients following ventricular assist device explant and heart transplantation. Perfusion 2021; 37:152-161. [PMID: 33482711 DOI: 10.1177/0267659121989229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND Vasoplegia has been shown to be associated with increased morbidity and mortality in patients undergoing cardiac surgery. It has been previously stated that low pulsatile states as seen with current left ventricular assist devices (LVADs) may contribute to vasoplegia post LVAD-explant and heart transplant. We sought to examine the literature regarding vasoplegia in the post-operative setting for patients undergoing LVAD explant and heart transplant. METHOD A literature review was conducted to firstly define vasoplegia in the setting of LVAD patients, and secondly to better understand the relationship between vasoplegia and LVAD explantation in the postoperative heart transplant patient cohort. A keyword search of 'vasoplegia' OR 'vasoplegic' AND 'transplant' was used. Search engines used were PubMed, Cochrane Library, ClinicalTrials.gov, Ovid, Scopus and grey literature. RESULTS 17 studies met the selection criteria for review. Three key themes emerged from the literature. Firstly, there is limited consensus regarding the definition of vasoplegia. Secondly, patients with LVADs experienced higher rates of vasoplegia following heart transplant than their counterparts and thirdly, increased cardiopulmonary bypass time was associated with a higher rate of vasoplegia. CONCLUSION Vasoplegia is not clearly defined in the literature as it pertains to the LVAD patient cohort. Patients bridged with LVADs appear to have higher rates of vasoplegia, however the aetiology of this is unclear and may be associated with continuous flow physiology or prolonged cardiopulmonary bypass time. A universal definition will aid in risk stratification, early recognition and management.
Collapse
Affiliation(s)
- Sam Emmanuel
- St Vincent's Hospital, Sydney, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, NSW, Australia.,School of Medicine, University of Notre Dame, Sydney, NSW, Australia.,The Victor Chang Cardiac Research Institute, Sydney, NSW, Australia
| | - Madeleine Pearman
- St Vincent's Hospital, Sydney, NSW, Australia.,School of Medicine, University of Notre Dame, Sydney, NSW, Australia
| | - Paul Jansz
- St Vincent's Hospital, Sydney, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, NSW, Australia.,School of Medicine, University of Notre Dame, Sydney, NSW, Australia.,The Victor Chang Cardiac Research Institute, Sydney, NSW, Australia
| | - Christopher Simon Hayward
- St Vincent's Hospital, Sydney, NSW, Australia.,School of Medicine, University of New South Wales, Sydney, NSW, Australia.,The Victor Chang Cardiac Research Institute, Sydney, NSW, Australia
| |
Collapse
|
21
|
Hydren JR, Gifford JR, Jarrett CL, Park SH, Shields KL, Broxterman RM, Kithas AC, Bisconti AV, Thurston TS, Ratchford SM, Wray DW, Stehlik J, Selzman CH, Drakos SG, Richardson RS. Vascular function in continuous-flow left ventricular assist device recipients: effect of a single pulsatility treatment session. Am J Physiol Regul Integr Comp Physiol 2021; 320:R425-R437. [PMID: 33438517 DOI: 10.1152/ajpregu.00274.2020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Vascular function is further attenuated in patients with chronic heart failure implanted with a continuous-flow left ventricular assist device (LVAD), likely due to decreased arterial pulsatility, and this may contribute to LVAD-associated cardiovascular complications. However, the impact of increasing pulsatility on vascular function in this population is unknown. Therefore, 15 LVAD recipients and 15 well-matched controls underwent a 45-min, unilateral, arm pulsatility treatment, evoked by intermittent cuff inflation/deflation (2-s duty cycle), distal to the elbow. Vascular function was assessed by percent brachial artery flow-mediated dilation (%FMD) and reactive hyperemia (RH) (Doppler ultrasound). Pretreatment, %FMD (LVAD: 4.0 ± 1.7; controls: 4.2 ± 1.4%) and RH (LVAD: 340 ± 101; controls: 308 ± 94 mL) were not different between LVAD recipients and controls; however, %FMD/shear rate was attenuated (LVAD: 0.10 ± 0.04; controls: 0.17 ± 0.06%/s-1, P < 0.05). The LVAD recipients exhibited a significantly attenuated pulsatility index (PI) compared with controls prior to treatment (LVAD: 2 ± 2; controls: 15 ± 7 AU, P < 0.05); however, during the treatment, PI was no longer different (LVAD: 37 ± 38; controls: 36 ± 14 AU). Although time to peak dilation and RH were not altered by the pulsatility treatment, %FMD (LVAD: 7.0 ± 1.8; controls: 7.4 ± 2.6%) and %FMD/shear rate (LVAD: 0.19 ± 0.07; controls: 0.33 ± 0.15%/s-1) increased significantly in both groups, with, importantly, %FMD/shear rate in the LVAD recipients being restored to that of the controls pretreatment. This study documents that a localized pulsatility treatment in LVAD recipients and controls can recover local vascular function, an important precursor to the development of approaches to increase systemic pulsatility and reduce systemic vascular complications in LVAD recipients.
Collapse
Affiliation(s)
- Jay R Hydren
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah
| | - Jayson R Gifford
- Department of Exercise Sciences, Brigham Young University, Provo, Utah
| | - Catherine L Jarrett
- Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah
| | - Soung Hun Park
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah
| | - Katherine L Shields
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah
| | - Ryan M Broxterman
- Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah
| | - Andrew C Kithas
- Department of Internal Medicine, University of Utah, Salt Lake City, Utah
| | - Angela Valentina Bisconti
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah.,Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah
| | - Taylor S Thurston
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah
| | - Stephen M Ratchford
- Department of Health and Exercise Science, Appalachian State University, Boone, North Carolina
| | - D Walter Wray
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah.,Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah.,Department of Internal Medicine, University of Utah, Salt Lake City, Utah
| | - Josef Stehlik
- Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah
| | - Craig H Selzman
- Department of Surgery, University of Utah School of Medicine, Salt Lake City, Utah
| | - Stavros G Drakos
- Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah
| | - Russell S Richardson
- Department of Nutrition and Integrative Physiology, University of Utah, Salt Lake City, Utah.,Geriatric Research, Education, and Clinical Center, Veterans Affairs Medical Center, Salt Lake City, Utah.,Department of Internal Medicine, University of Utah, Salt Lake City, Utah
| |
Collapse
|
22
|
Liu H, Liu S, Ma X. Varying speed modulation of continuous-flow left ventricular assist device based on cardiovascular coupling numerical model. Comput Methods Biomech Biomed Engin 2020; 24:956-972. [PMID: 33347766 DOI: 10.1080/10255842.2020.1861601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Continuous-flow left ventricular assist devices (CFLVADs) routinely operate at a constant speed for the support of a failing heart, which decreases the pulsatility in the arteries. Some late complications could be related to a long-term lack of pulsatility. Modulating the CFLVAD speed is a solution to enhance the pulsatility. The purpose of this study is to modulate multiple varying speed patterns and investigate their effects on the ventricle and vascular system. A cardiovascular coupling numerical model is developed to provide a simulation platform for testing the varying speed patterns. The varying speed patterns are modulated by combining the shape, amplitude, frequency, phase shift, and pulsatile duty cycle of the speed profile. The influence of varying speed support is examined by analyzing the indexes of pulsatility, indexes of ventricular unloading, and hemodynamic variables. The results show that the synchronous counterpulsation pattern can effectively reduce the ventricular unloading indexes, whereas the low-frequency asynchronous pattern can effectively increase the vascular pulsatility indexes. Also, the hemodynamics with synchronous varying speed support is more physiological than that with asynchronous varying speed support. This study provides valuable insight for further optimization of varying speed modulation by weighing vascular pulsatility, ventricular unloading, and hemodynamics.
Collapse
Affiliation(s)
- Hongtao Liu
- School of Electrical Engineering, Shandong University, Jinan, PR China
| | - Shuqin Liu
- School of Electrical Engineering, Shandong University, Jinan, PR China
| | - Xiaoxu Ma
- School of Electrical Engineering, Shandong University, Jinan, PR China
| |
Collapse
|
23
|
Targeting Peripheral Vascular Pulsatility in Heart Failure Patients with Continuous-Flow Left Ventricular Assist Devices: The Impact of Pump Speed. ASAIO J 2020; 66:291-299. [PMID: 30973399 DOI: 10.1097/mat.0000000000001001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Current continuous-flow left ventricular assist devices (LVADs) decrease peripheral vascular pulsatility, which may contribute to side effects such as bleeding and thrombotic events. However, the actual impact of manipulating LVAD pump speed, revolutions per minute (rpm), on peripheral (brachial) pulsatility index (brachial PI), in patients with heart failure implanted with a HeartWare (HVAD) or HeartMateII (HMII) LVAD is unknown. Therefore, blood velocities (Doppler ultrasound) in the brachial artery were recorded and brachial PI calculated across rpm manipulations which spanned the acceptable clinical outpatient range: 360 rpm (HVAD, n = 10) and 1200 rpm (HMII, n = 10). Left ventricular assist device-derived PIs were also recorded: HVAD maximal blood flow (HVADV max), HVAD minimum blood flow (HVADV min), and HMII PI (HMIIPI). Brachial PI changed significantly with rpm manipulations, from 2.3 ± 0.6 to 4.1 ± 0.8 (HVAD) and from 1.8 ± 0.5 to 3.6 ± 1.0 (HMII). Multilevel linear modeling with random intercepts revealed a 180 rpm decrease of the HVAD resulted in a 0.9 ± 0.1 (37 ± 4%, d = 2.65) increase in brachial PI and a 600 rpm decrease in the HMII resulted in a 0.8 ± 0.1 (38 ± 3%, d = 4.66) increase. Furthermore, a reduction in rpm resulted in a 20.0 ± 0.3% power savings, and a reduction in device reported blood flow of 9 ± 1%. Brachial PI was linearly related to HVADV max, HVADV min, their difference (R = 0.42, R = 0.65, and R = 0.54, respectively), and HMIIPI (R = 0.86). Manipulating LVAD pump speed, within a clinically acceptable outpatient range, resulted in a significant change in brachial PI, which was reflected by pump indices, documenting the potential for LVAD pump speed manipulations to improve LVAD outcomes.
Collapse
|
24
|
Ogawa D, Kobayashi S, Yamazaki K, Motomura T, Nishimura T, Shimamura J, Tsukiya T, Mizuno T, Takewa Y, Tatsumi E, Nishinaka T. Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model. Artif Organs 2020; 45:124-134. [PMID: 32813920 DOI: 10.1111/aor.13795] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 07/10/2020] [Accepted: 08/05/2020] [Indexed: 01/17/2023]
Abstract
We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in wider range of conditions to clarify its benefits and pitfalls prior to clinical application. In this study, we evaluated pulsatility and cardiac load reduction obtained with the CBS control on valvular failure conditions with a mathematical model. Diastolic assist could reduce cardiac load on the left ventricle by decreasing external work of the ventricle even in MR cases while it was not so effective in AR cases. Systolic assist can still promote pulsatility in AR and MR cases; however, aortic valve function should be carefully confirmed since pulse pressure can be wider not due to systolic assist but to AR.
Collapse
Affiliation(s)
- Daisuke Ogawa
- Sun Medical Technology Research Corp., Nagano, Japan
| | | | | | | | - Takashi Nishimura
- Department of Cardiovascular and Thoracic Surgery, Graduate school of Medicine, Ehime University, Ehime, Japan
| | - Junichi Shimamura
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Tomonori Tsukiya
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Toshihide Mizuno
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Yoshiaki Takewa
- Advanced Medical Engineering Research Center, Asahikawa Medical University, Hokkaido, Japan
| | - Eisuke Tatsumi
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Tomohiro Nishinaka
- Department of Artificial Organs, National Cerebral and Cardiovascular Center, Osaka, Japan.,Department of Cardiovascular Surgery, Graduate School of Medicine, Osaka University, Osaka, Japan
| |
Collapse
|
25
|
Melo TR, Neto JS, Cestari IA, Lima AM. Feedback controller for restoring the basal hemodynamic condition with a rotary blood pump used as left ventricular assist device. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Hockstein MA. Continuous-flow left ventricular assist devices: Management in the emergency department. J Am Coll Emerg Physicians Open 2020; 1:362-370. [PMID: 33000058 PMCID: PMC7493560 DOI: 10.1002/emp2.12178] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 06/06/2020] [Accepted: 06/10/2020] [Indexed: 11/25/2022] Open
Abstract
With an increasing number of left ventricular assist devices (LVADs) being placed every year, emergency clinicians are increasingly likely to encounter them in their practice. Patients may present to the emergency department (ED) with significant hemodynamic perturbations with an LVAD and it is imperative that emergency clinicians are able to assess and treat conditions contributing to low cardiac output states. This review describes the important aspects of the third generation of LVADs and their complications as well as common management approaches for the emergency physician.
Collapse
Affiliation(s)
- Maxwell A. Hockstein
- Department of Emergency Medicine; Department of Anesthesia, Division of Critical CareEmory University School of MedicineAtlantaGeorgiaUSA
| |
Collapse
|
27
|
Dort DIM, Thannhauser J, Gommans FDH, Ten Cate TJ, Duncker DJ, Suryapranata H, Morshuis WJ, Geuzebroek GSC. Proof of principle of a novel co‐pulsating intra‐ventricular membrane pump. Artif Organs 2020; 44:1267-1275. [DOI: 10.1111/aor.13757] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 06/04/2020] [Accepted: 06/08/2020] [Indexed: 12/15/2022]
Affiliation(s)
- Daniël I. M. Dort
- Department of Cardiothoracic Surgery Radboudumc Nijmegen The Netherlands
| | - Jos Thannhauser
- Department of Cardiology Radboudumc Nijmegen The Netherlands
| | | | - Tim J. Ten Cate
- Department of Cardiology Radboudumc Nijmegen The Netherlands
| | - Dirk J. Duncker
- Department of Experimental Cardiology Erasmus MC Rotterdam The Netherlands
| | | | - Wim J. Morshuis
- Department of Cardiothoracic Surgery Radboudumc Nijmegen The Netherlands
| | | |
Collapse
|
28
|
Wu EL, Fresiello L, Kleinhyer M, Meyns B, Fraser JF, Tansley G, Gregory SD. Haemodynamic Effect of Left Atrial and Left Ventricular Cannulation with a Rapid Speed Modulated Rotary Blood Pump During Rest and Exercise: Investigation in a Numerical Cardiorespiratory Model. Cardiovasc Eng Technol 2020; 11:350-361. [PMID: 32557185 DOI: 10.1007/s13239-020-00471-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 06/12/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE The left atrium and left ventricle are the primary inflow cannulation sites for heart failure patients supported by rotary blood pumps (RBPs). Haemodynamic differences exist between inflow cannulation sites and have been well characterized at rest, yet the effect during exercise with the same centrifugal RBP has not been previously well established. The purpose of this study was to investigate the hemodynamic effect of inflow cannulation site during rest and exercise with the same centrifugal RBP. METHODS In a numerical cardiorespiratory model, a simulated heart failure patient was supported by a HeartWare HVAD RBP in left atrial (LAC) and left ventricular cannulation (LVC). The RBP was operated at constant speed and sinusoidal co- and counter-pulse and was investigated in cardiovascular conditions of steady state rest and 80-watt bike graded exercise. RESULTS Cardiac output was 5.0 L min-1 during rest and greater than 6.9 L min-1 during exercise for all inflow cannulation sites and speed operating modes. However, during exercise, LAC demonstrated greater pressure-volume area and lower RBP flow (1.41, 1.37 and 1.37 J and 5.03, 5.12 and 5.03 L min-1 for constant speed and co- and counter-pulse respectively) when compared to LVC (pressure-volume area: 1.30, 1.27 and 1.32 J and RBP flow: 5.56, 5.71 and 5.59 L min-1 for constant speed and co- and counter-pulse respectively). CONCLUSION For a simulated heart failure patient intending to complete exercise, LVC seems to assure a better hemodynamic performance in terms of pressure-volume area unloading and increasing RBP flow.
Collapse
Affiliation(s)
- Eric L Wu
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia. .,School of Medicine, The University of Queensland, Brisbane, Queensland, Australia.
| | - Libera Fresiello
- Department of Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.,Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Matthias Kleinhyer
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Engineering and Built Environment, Griffith University, Gold Coast, Queensland, Australia
| | - Bart Meyns
- Department of Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - John F Fraser
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Medicine, The University of Queensland, Brisbane, Queensland, Australia
| | - Geoff Tansley
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Engineering and Built Environment, Griffith University, Gold Coast, Queensland, Australia
| | - Shaun D Gregory
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Medicine, The University of Queensland, Brisbane, Queensland, Australia.,Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Victoria, Australia.,Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| |
Collapse
|
29
|
Mondal S, Sankova S, Lee K, Sorensen E, Kaczorowski D, Mazzeffi M. Intraoperative and Early Postoperative Management of Patients Undergoing Minimally Invasive Left Ventricular Assist Device Implantation. J Cardiothorac Vasc Anesth 2020; 35:616-630. [PMID: 32505605 DOI: 10.1053/j.jvca.2020.04.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 04/03/2020] [Accepted: 04/09/2020] [Indexed: 11/11/2022]
Affiliation(s)
- Samhati Mondal
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Susan Sankova
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Khang Lee
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Erik Sorensen
- Department of Surgery, Division of Cardiothoracic Surgery, University of Maryland School of Medicine, Baltimore, MD
| | - David Kaczorowski
- Department of Surgery, Division of Cardiothoracic Surgery, University of Maryland School of Medicine, Baltimore, MD
| | - Michael Mazzeffi
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD.
| |
Collapse
|
30
|
Okamoto E, Yano T, Inoue Y, Shiraishi Y, Yambe T, Mitamura Y. In vitro performance of trans-valve left ventricular assist device installed at aortic valve position. Artif Organs 2020; 44:1067-1072. [PMID: 32216103 DOI: 10.1111/aor.13687] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 03/12/2020] [Accepted: 03/19/2020] [Indexed: 12/22/2022]
Abstract
In this study, we developed a trans-valve left ventricular assist device (LVAD) that unites a rear-impeller axial-flow blood pump (AFBP) and a polymer membrane valve placed at the aortic valve position. The diameter and length of the rear impeller AFBP was 12 and 63 mm, respectively. The polymer membrane valve was similar to the jelly-fish valve consisting of a valve leaflet made of silicone rubber (thickness 0.5 mm), valve ring (diameter: 25 mm), and valve spokes. The trans-valve LVAD was examined in a mock circulation. An implantable pulsatile flow (PF) VAD was connected to an atrial reservoir to simulate the left ventricle (LV), and the Hall valve was worn in the inflow port, and the trans-valve LVAD was placed in the outflow port as an outflow valve. When the motor rotational speed increased to 26 400 rpm, the mean aortic flow increased from 4.2 to 5.3 L/min, mean aortic pressure increased from 83.4 to 100 mm Hg, and mean motor current of the implantable PF VAD decreased from 1.18 to 0.94 A (unloading effect on LV -21%). The energy equivalent pressure increased from 85.2 to 102 mm Hg, and surplus hemodynamic energy (SHE) decreased by -15.4% from the baseline. In conclusion, the trans-valve LVAD has an advantage of preserving pulsatility without any complicated mechanism and is a novel and promising LV support device.
Collapse
Affiliation(s)
- Eiji Okamoto
- Sapporo Liberal Arts Center, Tokai University, Sapporo, Japan
| | - Tetsuya Yano
- Graduate School of Science and Engineering, Hirosaki University, Hirosaki, Japan
| | - Yusuke Inoue
- Institute of Development Aging and Cancer, Tohoku University, Sendai, Japan
| | - Yasuyuki Shiraishi
- Institute of Development Aging and Cancer, Tohoku University, Sendai, Japan
| | - Tomoyuki Yambe
- Institute of Development Aging and Cancer, Tohoku University, Sendai, Japan
| | | |
Collapse
|
31
|
Saeed MY, Van Story D, Payne CJ, Wamala I, Shin B, Bautista-Salinas D, Zurakowski D, del Nido PJ, Walsh CJ, Vasilyev NV. Dynamic Augmentation of Left Ventricle and Mitral Valve Function With an Implantable Soft Robotic Device. JACC Basic Transl Sci 2020; 5:229-242. [PMID: 32215347 PMCID: PMC7091510 DOI: 10.1016/j.jacbts.2019.12.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Revised: 12/03/2019] [Accepted: 12/03/2019] [Indexed: 01/18/2023]
Abstract
Left ventricular failure is strongly associated with secondary mitral valve regurgitation. Implantable soft robotic devices are an emerging technology that enables augmentation of a native function of a target tissue. We demonstrate the ability of a novel soft robotic ventricular assist device to dynamically augment left ventricular contraction, provide native pulsatile flow, simultaneously reshape the mitral valve apparatus, and eliminate the associated regurgitation in an Short-term large animal model of acute left ventricular systolic dysfunction.
Collapse
Key Words
- FS, fractional shortening
- HF, heart failure
- IQR, interquartile range
- IVS, interventricular septum
- LHF, left heart failure
- LV, left ventricular
- LVEDP, left ventricular end-diastolic pressure
- LVSD, left ventricular systolic dysfunction
- MV, mitral valve
- MVR, mitral valve regurgitation
- RV, right ventricle
- SRVAD, soft robotic ventricular assist device
- left ventricular systolic dysfunction
- mitral valve
- secondary mitral regurgitation
- soft robotic
Collapse
Affiliation(s)
- Mossab Y. Saeed
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - David Van Story
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - Christopher J. Payne
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, Massachusetts
- John A. Paulson Harvard School of Engineering and Applied Sciences, Harvard University, Boston, Massachusetts
| | - Isaac Wamala
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - Borami Shin
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - Daniel Bautista-Salinas
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
- School of Industrial Engineering, Technical University of Cartagena, Cartagena, Spain
| | - David Zurakowski
- Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - Pedro J. del Nido
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| | - Conor J. Walsh
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, Massachusetts
- John A. Paulson Harvard School of Engineering and Applied Sciences, Harvard University, Boston, Massachusetts
| | - Nikolay V. Vasilyev
- Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
32
|
Wu T, Khir AW, Kütting M, Du X, Lin H, Zhu Y, Hsu PL. A review of implantable pulsatile blood pumps: Engineering perspectives. Int J Artif Organs 2020; 43:559-569. [PMID: 32037940 DOI: 10.1177/0391398820902470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
It has been reported that long-term use of continuous-flow mechanical circulatory support devices (CF-MCSDs) may induce complications associated with diminished pulsatility. Pulsatile-flow mechanical circulatory support devices (PF-MCSDs) have the potential of overcoming these shortcomings with the advance of technology. In order to promote in-depth understanding of PF-MCSD technology and thus encourage future mechanical circulatory support device innovations, engineering perspectives of PF-MCSD systems, including mechanical designs, drive mechanisms, working principles, and implantation strategies, are reviewed in this article. Some emerging designs of PF-MCSDs are introduced, and possible elements for next-generation PF-MCSDs are identified.
Collapse
Affiliation(s)
- Tingting Wu
- Artificial Organ Technology Laboratory, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Ashraf W Khir
- Brunel Institute for Bioengineering, Brunel University London, Uxbridge, UK
| | | | - Xinli Du
- Brunel Institute for Bioengineering, Brunel University London, Uxbridge, UK
| | - Hao Lin
- Artificial Organ Technology Laboratory, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Yuxin Zhu
- Artificial Organ Technology Laboratory, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Po-Lin Hsu
- Artificial Organ Technology Laboratory, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
33
|
Influence of Impeller Speed Patterns on Hemodynamic Characteristics and Hemolysis of the Blood Pump. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9214689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A continuous-flow output mode of a rotary blood pump reduces the fluctuation range of arterial blood pressure and easily causes complications. For a centrifugal rotary blood pump, sinusoidal and pulsatile speed patterns are designed using the impeller speed modulation. This study aimed to analyze the hemodynamic characteristics and hemolysis of different speed patterns of a blood pump in patients with heart failure using computational fluid dynamics (CFD) and the lumped parameter model (LPM). The results showed that the impeller with three speed patterns (including the constant speed pattern) met the normal blood demand of the human body. The pulsating flow generated by the impeller speed modulation effectively increased the maximum pulse pressure (PP) to 12.7 mm Hg, but the hemolysis index (HI) in the sinusoidal and pulsatile speed patterns was higher than that in the constant speed pattern, which was about 2.1 × 10−5. The flow path of the pulsating flow field in the spiral groove of the hydrodynamic suspension bearing was uniform, but the alternating high shear stress (0~157 Pa) was caused by the impeller speed modulation, causing blood damage. Therefore, the rational modulation of the impeller speed and the structural optimization of a blood pump are important for improving hydrodynamic characteristics and hemolysis.
Collapse
|
34
|
WU XIAO, ZHANG XIWEN, HAO PENGFEI, HE FENG. COMPARISON OF THREE CONTROL STRATEGIES FOR AXIAL BLOOD PUMP. J MECH MED BIOL 2019. [DOI: 10.1142/s0219519419500581] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Facing the gradually increased prevalence of heart failure (HF) and the shortage of donated hearts, the blood pump is widely used to prolong the life of end-stage HF patients: however, the pump generates continuous flow under constant rotational speed, declining the arterial pulsatility and causing related complications. Previous studies show that synchronous copulsation might be the best control strategy for restoring pulsatility, but synchronous strategies are needed to monitor the phase of the heartbeat, which will make the controller complex and impair its robustness. Here, we compare constant speed, synchronous copulsation in a model of a cardiovascular system with a blood pump, which shows that copulsation offers more arterial pulsatility, less pump power-consumption, and thus better battery endurance, and constant speed offers a greater ventricular unloading effect. Meanwhile, we design a strategy based on transforming left ventricular pressure, which is easier to implement and has similar effect to synchronous copulsation.
Collapse
Affiliation(s)
- XIAO WU
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - XIWEN ZHANG
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - PENGFEI HAO
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - FENG HE
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
35
|
Cross TJ, Sajgalik P, Fabian V, Matera L, Kushwaha SS, Maltais S, Stulak JM, Schirger JA, Johnson BD. Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices. Int J Artif Organs 2019; 43:99-108. [PMID: 31411101 DOI: 10.1177/0391398819868236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'. PURPOSE The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. METHODS Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m-2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient's dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). RESULTS The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. CONCLUSIONS The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
Collapse
Affiliation(s)
- Troy J Cross
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.,Menzies Health Institute Queensland, Griffith University, Southport, QLD, Australia
| | - Pavol Sajgalik
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Vratislav Fabian
- Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| | - Lukas Matera
- Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| | - Sudhir S Kushwaha
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Simon Maltais
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA
| | - John M Stulak
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA
| | - John A Schirger
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Bruce D Johnson
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
36
|
Ogawa D, Kobayashi S, Yamazaki K, Motomura T, Nishimura T, Shimamura J, Tsukiya T, Mizuno T, Takewa Y, Tatsumi E. Mathematical evaluation of cardiac beat synchronization control used for a rotary blood pump. J Artif Organs 2019; 22:276-285. [DOI: 10.1007/s10047-019-01117-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Accepted: 07/08/2019] [Indexed: 10/26/2022]
|
37
|
Anjum A, Kurihara C, Critsinelis A, Kawabori M, Sugiura T, Civitello AB, Etheridge WB, Delgado RM, Simpson L, George JK, Nair AP, Frazier OH, Morgan JA. Acute kidney injury after implantation of a left ventricular assist device: a comparison of axial-flow (HeartMate II) and centrifugal-flow (HeartWare HVAD) devices. J Artif Organs 2018; 21:285-292. [DOI: 10.1007/s10047-018-1047-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 05/08/2018] [Indexed: 12/17/2022]
|
38
|
Noninvasive Measures of Pulsatility and Blood Pressure During Continuous-Flow Left Ventricular Assist Device Support. ASAIO J 2018; 65:241-246. [PMID: 29734257 DOI: 10.1097/mat.0000000000000805] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The reliability and validity of a palpable pulse and other noninvasive measures of pulsatility in patients on continuous-flow (CF) left ventricular assist device (LVAD) support have not been rigorously evaluated. We prospectively enrolled 23 patients who had CF-LVAD and an arterial catheter for blood pressure (BP) monitoring. Pulse pressure (PP) via the arterial line was compared with three noninvasive measures of pulsatility: presence of a palpable pulse, pulsatility index (PI), and aortic valve opening (AVO). In addition, the relationship between Doppler BP (DopBP) and arterial line pressures was evaluated. The study group comprised 30% females, 73% nonischemic cardiomyopathy, 87% axial flow device (HeartMate II [HMII]), and 13% centrifugal flow device (HeartWare ventricular assist device [HVAD]) support. Among four practitioners, the interobserver agreement for the presence of a palpable pulse was moderate (k = 0.41; 95% CI, 0.28-0.60). If the PP was ≥15 mm Hg, a radial pulse was palpated 82% of the time, whereas when the PP was <15 mm Hg, a radial pulse was palpated only 35% of the time. In subjects with a palpable pulse, there was a strong correlation between DopBP and systolic BP (SBP) (r = 0.94; 95% CI, 0.82-0.99), whereas the correlation between DopBP and mean arterial pressure (MAP) was much weaker (r = 0.42; 95% CI, 0.19-0.96). In subjects without a palpable pulse, there was a strong correlation between both the DopBP and SBP (r = 0.94; 95% CI, 0.80-1.0) and DopBP and MAP (r = 0.87; 95% CI, 0.77-1.00). Finally, PP was significantly associated with PI (odds ratio [OR], 0.3; 95% CI, 0.14-0.45; p = 0.0002) but not AVO (OR, 1.41: 95% CI, 0.70-2.83; p = 0.33). The presence of a palpable pulse has good interobserver agreement and allows for dichotomization of the DopBP to reflect the SBP in its presence and the MAP in its absence. This simple measure should be incorporated into BP management algorithms for CF-LVADs. The PI shows a modest correlation to PP.
Collapse
|
39
|
Vincent F, Rauch A, Loobuyck V, Robin E, Nix C, Vincentelli A, Smadja DM, Leprince P, Amour J, Lemesle G, Spillemaeker H, Debry N, Latremouille C, Jansen P, Capel A, Moussa M, Rousse N, Schurtz G, Delhaye C, Paris C, Jeanpierre E, Dupont A, Corseaux D, Rosa M, Sottejeau Y, Barth S, Mourran C, Gomane V, Coisne A, Richardson M, Caron C, Preda C, Ung A, Carpentier A, Hubert T, Denis C, Staels B, Lenting PJ, Van Belle E, Susen S. Arterial Pulsatility and Circulating von Willebrand Factor in Patients on Mechanical Circulatory Support. J Am Coll Cardiol 2018; 71:2106-2118. [DOI: 10.1016/j.jacc.2018.02.075] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 01/25/2018] [Accepted: 02/25/2018] [Indexed: 01/27/2023]
|
40
|
Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study. Cardiovasc Eng Technol 2017; 8:439-452. [PMID: 28707188 DOI: 10.1007/s13239-017-0314-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 06/17/2017] [Indexed: 10/19/2022]
Abstract
Mechanical circulatory support (MCS) devices have become a standard therapy for heart failure (HF) patients. MCS device designs may differ by level of support, inflow and/or outflow cannulation sites, and mechanism(s) of cardiac unloading and blood flow delivery. Investigation and direct comparison of hemodynamic parameters that help characterize performance of MCS devices has been limited. We quantified cardiac and vascular hemodynamic responses for different types of MCS devices. Continuous flow (CF) left ventricular (LV) assist devices (LVAD) with LV or left atrial (LA) inlet, counterpulsation devices, percutaneous CF LVAD, and intra-aortic rotary blood pumps (IARBP) were quantified using established computer simulation and mock flow loop models. Hemodynamic data were analyzed on a beat-to-beat basis at baseline HF and over a range of MCS support. Results demonstrated that all LVAD greatly diminished vascular pulsatility (P) and LV external work (LVEW). LVAD with LA inflow provided a greater reduction in LVEW compared to LVAD with LV inflow, but at the potential risk for blood stasis/thrombosis in the LV at high support. Counterpulsation provided greater coronary flow (CoF) augmentation, but had a lower reduction in LVEW compared to partial percutaneous LVAD support. IARBP diminished LVEW, but at the expense of diminished CoF due to coronary steal. The hemodynamic benefits for each type of mechanical circulatory support system are unique and clinical decisions on device selection to maximize end organ perfusion and minimize invasiveness needs to be considered for an individual patients' presentation.
Collapse
|
41
|
Non-occlusive mesenteric ischemia in a patient with left ventricular assist device implantation. J Artif Organs 2017; 20:277-279. [PMID: 28580527 DOI: 10.1007/s10047-017-0964-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 04/27/2017] [Indexed: 10/19/2022]
Abstract
Non-occlusive mesenteric ischemia (NOMI) is a devastating complication after cardiac surgery. Once patients develop NOMI, intra-mesenteric infusion of vasodilators and/or emergent laparotomy is usually required, but the mortality is extraordinarily high even with intensive treatment. We present a case of salvage of a patient with NOMI complicated with severe right ventricular dysfunction after left ventricular assist device (LVAD) implantation using maximum treatment with emergent laparotomy and temporary right ventricular assist device implantation. To the best of our knowledge, this is the first successful salvage case of NOMI in a LVAD patient. We believe that hemodynamic optimization using maximum treatment is critically important to achieve salvage.
Collapse
|
42
|
Rüschen D, Prochazka F, Amacher R, Bergmann L, Leonhardt S, Walter M. Minimizing left ventricular stroke work with iterative learning flow profile control of rotary blood pumps. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.09.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
43
|
Capoccia M. Mechanical Circulatory Support for Advanced Heart Failure: Are We about to Witness a New "Gold Standard"? J Cardiovasc Dev Dis 2016; 3:E35. [PMID: 29367578 PMCID: PMC5715724 DOI: 10.3390/jcdd3040035] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Revised: 12/03/2016] [Accepted: 12/06/2016] [Indexed: 01/08/2023] Open
Abstract
The impact of left ventricular assist devices (LVADs) for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs), based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs). The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial) and the HeartWare HVAD (centrifugal) rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal) is now emerging as the new promising device with encouraging preliminary results. There are now enough pumps on the market: it is time to focus on the complications in order to achieve the full potential and selling-point of this type of technology for the treatment of the increasing heart failure patient population.
Collapse
Affiliation(s)
- Massimo Capoccia
- Scottish National Advanced Heart Failure Service, Golden Jubilee National Hospital, Glasgow G81 4DY, UK.
- Biomedical Engineering, University of Strathclyde, Glasgow G4 0NW, UK.
| |
Collapse
|
44
|
Kleinheyer M, Timms DL, Tansley GD, Nestler F, Greatrex NA, Frazier OH, Cohn WE. Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller. Artif Organs 2016; 40:824-33. [DOI: 10.1111/aor.12827] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 07/05/2016] [Accepted: 07/06/2016] [Indexed: 12/25/2022]
Affiliation(s)
- Matthias Kleinheyer
- School of Engineering; Griffith University; Southport Queensland Australia
- Department of Engineering; BiVACOR Inc.; Houston TX USA
| | | | | | - Frank Nestler
- Department of Engineering; BiVACOR Inc.; Houston TX USA
- School of Information Technology and Electrical Engineering; The University of Queensland; St. Lucia, Queensland Australia
| | | | - O. Howard Frazier
- Department of Engineering; BiVACOR Inc.; Houston TX USA
- Department of Cardiovascular Surgery; Texas Heart Institute; Houston TX USA
| | - William E. Cohn
- Department of Engineering; BiVACOR Inc.; Houston TX USA
- Department of Cardiovascular Surgery; Texas Heart Institute; Houston TX USA
| |
Collapse
|
45
|
Date K, Nishimura T, Arakawa M, Takewa Y, Kishimoto S, Umeki A, Ando M, Mizuno T, Tsukiya T, Ono M, Tatsumi E. Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device. J Artif Organs 2016; 20:18-25. [DOI: 10.1007/s10047-016-0920-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 07/12/2016] [Indexed: 10/21/2022]
|
46
|
Evaluation of the effect of diminished pulsatility as seen in continuous flow ventricular assist devices on arterial endothelial cell phenotype and function. J Heart Lung Transplant 2016; 35:930-2. [DOI: 10.1016/j.healun.2016.03.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 02/29/2016] [Accepted: 03/11/2016] [Indexed: 11/19/2022] Open
|
47
|
Abstract
Despite >100 clinical trials, only 2 new drugs had been approved by the US Food and Drug Administration for the treatment of chronic heart failure in more than a decade: the aldosterone antagonist eplerenone in 2003 and a fixed dose combination of hydralazine-isosorbide dinitrate in 2005. In contrast, 2015 has witnessed the Food and Drug Administration approval of 2 new drugs, both for the treatment of chronic heart failure with reduced ejection fraction: ivabradine and another combination drug, sacubitril/valsartan or LCZ696. Seemingly overnight, a range of therapeutic possibilities, evoking new physiological mechanisms, promise great hope for a disease that often carries a prognosis worse than many forms of cancer. Importantly, the newly available therapies represent a culmination of basic and translational research that actually spans many decades. This review will summarize newer drugs currently being used in the treatment of heart failure, as well as newer strategies increasingly explored for their utility during the stages of the heart failure syndrome.
Collapse
Affiliation(s)
- Anjali Tiku Owens
- From the Cardiovascular Division, Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia
| | - Susan C Brozena
- From the Cardiovascular Division, Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia
| | - Mariell Jessup
- From the Cardiovascular Division, Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia.
| |
Collapse
|
48
|
Date K, Nishimura T, Takewa Y, Kishimoto S, Arakawa M, Umeki A, Ando M, Mizuno T, Tsukiya T, Ono M, Tatsumi E. Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system. J Artif Organs 2016; 19:315-321. [DOI: 10.1007/s10047-016-0906-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Accepted: 05/08/2016] [Indexed: 10/21/2022]
|
49
|
Kleinheyer M, Timms DL, Greatrex NA, Masuzawa T, Frazier OH, Cohn WE. Pulsatile operation of the BiVACOR TAH - Motor design, control and hemodynamics. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:5659-62. [PMID: 25571279 DOI: 10.1109/embc.2014.6944911] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Although there is limited consensus about the strict requirement to deliver pulsatile perfusion to the human circulatory system, speed modulation of rotary blood pumps is an approach that may capture the benefits of both positive displacement and continuous flow blood pumps. In the current stage of development of the BiVACOR Total Artificial Heart emphasis is placed on providing pulsatile outflow from the pump. Multiple pulsatile speed profiles have been applied in preliminary in-vivo operation in order to assess the capability of the TAH to recreate a physiologic pulse. This paper provides an overview about recent research towards pulsatile BiVACOR operation with special emphasis on motor and control requirements and developments.
Collapse
|
50
|
Feasibility of Pump Speed Modulation for Restoring Vascular Pulsatility with Rotary Blood Pumps. ASAIO J 2015; 61:526-32. [DOI: 10.1097/mat.0000000000000262] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
|