Geerardyn A, Zhu M, Verhaert N, Quesnel AM. Intracochlear Trauma and Local Ossification Patterns Differ Between Straight and Precurved Cochlear Implant Electrodes. Otol Neurotol 2024; 45:245-255. [PMID: 38270168 PMCID: PMC10922381 DOI: 10.1097/mao.0000000000004102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
HYPOTHESIS Trauma to the osseous spiral lamina (OSL) or spiral ligament (SL) during cochlear implant (CI) insertion segregates with electrode type and induces localized intracochlear ossification and fibrosis. BACKGROUND The goal of atraumatic CI insertion is to preserve intracochlear structures, limit reactive intracochlear tissue formation, and preserve residual hearing. Previous qualitative studies hypothesized a localized effect of trauma on intracochlear tissue formation; however, quantitative studies failed to confirm this. METHODS Insertional trauma beyond the immediate insertion site was histologically assessed in 21 human temporal bones with a CI. Three-dimensional reconstructions were generated and virtually resectioned perpendicular to the cochlear spiral at high resolution. The cochlear volume occupied by ossification or fibrosis was determined at the midpoint of the trauma and compared with regions proximal and distal to this point. RESULTS Seven cases, all implanted with precurved electrodes, showed an OSL fracture beyond the immediate insertion site. Significantly more intracochlear ossification was observed at the midpoint of the OSL fracture, compared with the -26 to -18 degrees proximal and 28 to 56 degrees distal to the center. No such pattern was observed for fibrosis. In the 12 cases with a perforation of the SL (9 straight and 3 precurved electrodes), no localized pattern of ossification or fibrosis was observed around these perforations. CONCLUSION OSL fractures were observed exclusively with precurved electrodes in this study and may serve as a nidus for localized intracochlear ossification. Perforation of the SL, in contrast, predominantly occurred with straight electrodes and was not associated with localized ossification.
Collapse
Affiliation(s)
| | - MengYu Zhu
- Otopathology Laboratory, Massachusetts Eye and Ear, Boston, Massachusetts, USA
| | | | | |
Collapse
|
2
|
Thomas WM, Zuniga SA, Sondh I, Leber M, Solzbacher F, Lenarz T, Lim HH, Warren DJ, Rieth L, Adams ME. Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant. Front Neurosci 2024; 18:1308663. [PMID: 38379760 PMCID: PMC10877721 DOI: 10.3389/fnins.2024.1308663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/02/2024] [Indexed: 02/22/2024] Open
Abstract
Cochlear implants are among the most successful neural prosthetic devices to date but exhibit poor frequency selectivity and the inability to consistently activate apical (low frequency) spiral ganglion neurons. These issues can limit hearing performance in many cochlear implant patients, especially for understanding speech in noisy environments and in perceiving or appreciating more complex inputs such as music and multiple talkers. For cochlear implants, electrical current must pass through the bony wall of the cochlea, leading to widespread activation of auditory nerve fibers. Cochlear implants also cannot be implanted in some individuals with an obstruction or severe malformations of the cochlea. Alternatively, intraneural stimulation delivered via an auditory nerve implant could provide direct contact with neural fibers and thus reduce unwanted current spread. More confined current during stimulation can increase selectivity of frequency fiber activation. Furthermore, devices such as the Utah Slanted Electrode Array can provide access to the full cross section of the auditory nerve, including low frequency fibers that are difficult to reach using a cochlear implant. However, further scientific and preclinical research of these Utah Slanted Electrode Array devices is limited by the lack of a chronic large animal model for the auditory nerve implant, especially one that leverages an appropriate surgical approach relevant for human translation. This paper presents a newly developed transbullar translabyrinthine surgical approach for implanting the auditory nerve implant into the cat auditory nerve. In our first of a series of studies, we demonstrate a surgical approach in non-recovery experiments that enables implantation of the auditory nerve implant into the auditory nerve, without damaging the device and enabling effective activation of the auditory nerve fibers, as measured by electrode impedances and electrically evoked auditory brainstem responses. These positive results motivate performing future chronic cat studies to assess the long-term stability and function of these auditory nerve implant devices, as well as development of novel stimulation strategies that can be translated to human patients.
Collapse
Affiliation(s)
- W. Mitchel Thomas
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Steven A. Zuniga
- Department of Otolaryngology-Head and Neck Surgery, University of Minnesota, Minneapolis, MN, United States
| | - Inderbir Sondh
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Moritz Leber
- Blackrock Neurotech, Salt Lake City, UT, United States
| | - Florian Solzbacher
- Blackrock Neurotech, Salt Lake City, UT, United States
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, United States
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Medical University of Hannover, Hannover, Germany
| | - Hubert H. Lim
- Department of Otolaryngology-Head and Neck Surgery, University of Minnesota, Minneapolis, MN, United States
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - David J. Warren
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, United States
| | - Loren Rieth
- Department Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV, United States
| | - Meredith E. Adams
- Department of Otolaryngology-Head and Neck Surgery, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|
3
|
Xu M, Liu Y, Yang K, Li S, Wang M, Wang J, Yang D, Shkunov M, Silva SRP, Castro FA, Zhao Y. Minimally invasive power sources for implantable electronics. EXPLORATION (BEIJING, CHINA) 2024; 4:20220106. [PMID: 38854488 PMCID: PMC10867386 DOI: 10.1002/exp.20220106] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 06/08/2023] [Indexed: 06/11/2024]
Abstract
As implantable medical electronics (IMEs) developed for healthcare monitoring and biomedical therapy are extensively explored and deployed clinically, the demand for non-invasive implantable biomedical electronics is rapidly surging. Current rigid and bulky implantable microelectronic power sources are prone to immune rejection and incision, or cannot provide enough energy for long-term use, which greatly limits the development of miniaturized implantable medical devices. Herein, a comprehensive review of the historical development of IMEs and the applicable miniaturized power sources along with their advantages and limitations is given. Despite recent advances in microfabrication techniques, biocompatible materials have facilitated the development of IMEs system toward non-invasive, ultra-flexible, bioresorbable, wireless and multifunctional, progress in the development of minimally invasive power sources in implantable systems has remained limited. Here three promising minimally invasive power sources summarized, including energy storage devices (biodegradable primary batteries, rechargeable batteries and supercapacitors), human body energy harvesters (nanogenerators and biofuel cells) and wireless power transfer (far-field radiofrequency radiation, near-field wireless power transfer, ultrasonic and photovoltaic power transfer). The energy storage and energy harvesting mechanism, configurational design, material selection, output power and in vivo applications are also discussed. It is expected to give a comprehensive understanding of the minimally invasive power sources driven IMEs system for painless health monitoring and biomedical therapy with long-term stable functions.
Collapse
Affiliation(s)
- Ming Xu
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - Yuheng Liu
- Department of Chemical and Process Engineering University of Surrey Guildford Surrey UK
| | - Kai Yang
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - Shaoyin Li
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - Manman Wang
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - Jianan Wang
- Department of Environmental Science and Engineering Xi'an Jiaotong University Xi'an China
| | - Dong Yang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education School of Life Science and Technology Xi'an Jiaotong University Xi'an China
| | - Maxim Shkunov
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - S Ravi P Silva
- Advanced Technology Institute University of Surrey Guildford Surrey UK
| | - Fernando A Castro
- Advanced Technology Institute University of Surrey Guildford Surrey UK
- National Physical Laboratory Teddington Middlesex UK
| | - Yunlong Zhao
- National Physical Laboratory Teddington Middlesex UK
- Dyson School of Design Engineering Imperial College London London UK
| |
Collapse
|
4
|
Geerardyn A, Zhu M, Klabbers T, Huinck W, Mylanus E, Nadol JB, Verhaert N, Quesnel AM. Human Histology after Structure Preservation Cochlear Implantation via Round Window Insertion. Laryngoscope 2024; 134:945-953. [PMID: 37493203 DOI: 10.1002/lary.30900] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 06/22/2023] [Accepted: 07/05/2023] [Indexed: 07/27/2023]
Abstract
OBJECTIVES Current surgical techniques aim to preserve intracochlear structures during cochlear implant (CI) insertion to maintain residual cochlear function. The optimal technique to minimize damage, however, is still under debate. The aim of this study is to histologically compare insertional trauma and intracochlear tissue formation in humans with a CI implanted via different insertion techniques. METHODS One recent temporal bone from a donor who underwent implantation of a full-length CI (576°) via round window (RW) insertion was compared with nine cases implanted via cochleostomy (CO) or extended round window (ERW) approach. Insertional trauma was assessed on H&E-stained histological sections. 3D reconstructions were generated and virtually re-sectioned to measure intracochlear volumes of fibrosis and neo-ossification. RESULTS The RW insertion case showed electrode translocation via the spiral ligament. 2/9 CO/ERW cases showed no insertional trauma. The total volume of the cochlea occupied by fibro-osseous tissue was 10.8% in the RW case compared with a mean of 30.6% (range 8.7%-44.8%, N = 9) in the CO/ERW cases. The difference in tissue formation in the basal 5 mm of scala tympani, however, was even more pronounced when the RW case (12.3%) was compared with the cases with a CO/ERW approach (mean of 93.8%, range 81% to 100%, N = 9). CONCLUSIONS Full-length CI insertions via the RW can be minimally traumatic at the cochlear base without inducing extensive fibro-osseous tissue formation locally. The current study further supports the hypothesis that drilling of the cochleostomy with damage to the endosteum incites a local tissue reaction. LEVEL OF EVIDENCE 4: Case-control study Laryngoscope, 134:945-953, 2024.
Collapse
Affiliation(s)
- Alexander Geerardyn
- Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
- Otopathology Laboratory, Massachusetts Eye and Ear, Boston, Massachusetts, U.S.A
- ExpORL, Department of Neurosciences, Katholieke Universiteit Leuven, Leuven, Belgium
| | - MengYu Zhu
- Otopathology Laboratory, Massachusetts Eye and Ear, Boston, Massachusetts, U.S.A
| | - Tim Klabbers
- Department of Otorhinolaryngology, Radboudumc, Nijmegen, the Netherlands
- Donders Institute for Brain, Cognition and Behaviour, Nijmegen, the Netherlands
| | - Wendy Huinck
- Department of Otorhinolaryngology, Radboudumc, Nijmegen, the Netherlands
- Donders Institute for Brain, Cognition and Behaviour, Nijmegen, the Netherlands
| | - Emmanuel Mylanus
- Department of Otorhinolaryngology, Radboudumc, Nijmegen, the Netherlands
- Donders Institute for Brain, Cognition and Behaviour, Nijmegen, the Netherlands
| | - Joseph B Nadol
- Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
- Otopathology Laboratory, Massachusetts Eye and Ear, Boston, Massachusetts, U.S.A
| | - Nicolas Verhaert
- ExpORL, Department of Neurosciences, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Alicia M Quesnel
- Department of Otolaryngology-Head & Neck Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
- Otopathology Laboratory, Massachusetts Eye and Ear, Boston, Massachusetts, U.S.A
| |
Collapse
|
5
|
Human cochlear microstructures at risk of electrode insertion trauma, elucidated in 3D with contrast-enhanced microCT. Sci Rep 2023; 13:2191. [PMID: 36750646 PMCID: PMC9905077 DOI: 10.1038/s41598-023-29401-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 02/03/2023] [Indexed: 02/09/2023] Open
Abstract
Cochlear implant restores hearing loss through electrical stimulation of the hearing nerve from within the cochlea. Unfortunately, surgical implantation of this neuroprosthesis often traumatizes delicate intracochlear structures, resulting in loss of residual hearing and compromising hearing in noisy environments and appreciation of music. To avoid cochlear trauma, insertion techniques and devices have to be adjusted to the cochlear microanatomy. However, existing techniques were unable to achieve a representative visualization of the human cochlea: classical histology damages the tissues and lacks 3D perspective; standard microCT fails to resolve the cochlear soft tissues; and previously used X-ray contrast-enhancing staining agents are destructive. In this study, we overcame these limitations by performing contrast-enhanced microCT imaging (CECT) with a novel polyoxometalate staining agent Hf-WD POM. With Hf-WD POM-based CECT, we achieved nondestructive, high-resolution, simultaneous, 3D visualization of the mineralized and soft microstructures in fresh-frozen human cochleae. This enabled quantitative analysis of the true intracochlear dimensions and led to anatomical discoveries, concerning surgically-relevant microstructures: the round window membrane, the Rosenthal's canal and the secondary spiral lamina. Furthermore, we demonstrated that Hf-WD POM-based CECT enables quantitative assessment of these structures as well as their trauma.
Collapse
|
6
|
Zhou N, Shi X, Dixit O, Firszt JB, Holden TA. Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better? Heliyon 2023; 9:e12467. [PMID: 36852047 PMCID: PMC9958279 DOI: 10.1016/j.heliyon.2022.e12467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 10/21/2022] [Accepted: 12/11/2022] [Indexed: 12/24/2022] Open
Abstract
Temporal modulation sensitivity has been studied extensively for cochlear implant (CI) users due to its strong correlation to speech recognition outcomes. Previous studies reported that temporal modulation detection thresholds (MDTs) vary across the tonotopic axis and attributed this variation to patchy neural survival. However, correlates of neural health identified in animal models depend on electrode position in humans. Nonetheless, the relationship between MDT and electrode location has not been explored. We tested 13 ears for the effect of distance on modulation sensitivity, specifically targeting the question of whether electrodes closer to the modiolus are universally beneficial. Participants in this study were postlingually deafened and users of Cochlear Nucleus CIs. The distance of each electrode from the medial wall (MW) of the cochlea and mid-modiolar axis (MMA) was measured from scans obtained using computerized tomography (CT) imaging. The distance measures were correlated with slopes of spatial tuning curves measured on selected electrodes to investigate if electrode position accounts, at least in part, for the width of neural excitation. In accordance with previous findings, electrode position explained 24% of the variance in slopes of the spatial tuning curves. All functioning electrodes were also measured for MDTs. Five ears showed a positive correlation between MDTs and at least one distance measure across the array; 6 ears showed negative correlations and the remaining two ears showed no relationship. The ears showing positive MDT-distance correlations, thus benefiting from electrodes being close to the neural elements, were those who performed better on the two speech recognition measures, i.e., speech reception thresholds (SRTs) and recognition of the AzBio sentences. These results could suggest that ears able to take advantage of the proximal placement of electrodes are likely to have better speech recognition outcomes. Previous histological studies of humans demonstrated that speech recognition is correlated with spiral ganglion cell counts. Alternatively, ears with good speech recognition outcomes may have good overall neural health, which is a precondition for close electrodes to produce spatially confined neural excitation patterns that facilitate modulation sensitivity. These findings suggest that the methods to reduce channel interaction, e.g., perimodiolar electrode array or current focusing, may only be beneficial for a subgroup of CI users. Additionally, it suggests that estimating neural survival preoperatively is important for choosing the most appropriate electrode array type (perimodiolar vs. lateral wall) for optimal implant function.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - Xuyang Shi
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - Omkar Dixit
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - Jill B Firszt
- Department of Otolaryngology, Washington University School of Medicine, St. Louis, Missouri, 63110, USA
| | - Timothy A Holden
- Department of Otolaryngology, Washington University School of Medicine, St. Louis, Missouri, 63110, USA
| |
Collapse
|
7
|
Starovoyt A, Quirk BC, Putzeys T, Kerckhofs G, Nuyts J, Wouters J, McLaughlin RA, Verhaert N. An optically-guided cochlear implant sheath for real-time monitoring of electrode insertion into the human cochlea. Sci Rep 2022; 12:19234. [PMID: 36357503 PMCID: PMC9649659 DOI: 10.1038/s41598-022-23653-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 11/03/2022] [Indexed: 11/12/2022] Open
Abstract
In cochlear implant surgery, insertion of perimodiolar electrode arrays into the scala tympani can be complicated by trauma or even accidental translocation of the electrode array within the cochlea. In patients with partial hearing loss, cochlear trauma can not only negatively affect implant performance, but also reduce residual hearing function. These events have been related to suboptimal positioning of the cochlear implant electrode array with respect to critical cochlear walls of the scala tympani (modiolar wall, osseous spiral lamina and basilar membrane). Currently, the position of the electrode array in relation to these walls cannot be assessed during the insertion and the surgeon depends on tactile feedback, which is unreliable and often comes too late. This study presents an image-guided cochlear implant device with an integrated, fiber-optic imaging probe that provides real-time feedback using optical coherence tomography during insertion into the human cochlea. This novel device enables the surgeon to accurately detect and identify the cochlear walls ahead and to adjust the insertion trajectory, avoiding collision and trauma. The functionality of this prototype has been demonstrated in a series of insertion experiments, conducted by experienced cochlear implant surgeons on fresh-frozen human cadaveric cochleae.
Collapse
Affiliation(s)
- Anastasiya Starovoyt
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium
| | - Bryden C. Quirk
- grid.1010.00000 0004 1936 7304Australian Research Council Centre of Excellence for Nanoscale BioPhotonics, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1010.00000 0004 1936 7304Institute for Photonics and Advanced Sensing, The University of Adelaide, Adelaide, SA 5005 Australia
| | - Tristan Putzeys
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, 3000 Leuven, Belgium
| | - Greet Kerckhofs
- grid.7942.80000 0001 2294 713XBiomechanics Laboratory, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, 1348 Louvain-La-Neuve, Belgium ,grid.5596.f0000 0001 0668 7884Department of Materials Science and Engineering, KU Leuven, 3000 Leuven, Belgium ,grid.7942.80000 0001 2294 713XInstitute of Experimental and Clinical Research, UCLouvain, 1200 Woluwé-Saint-Lambert, Belgium ,grid.5596.f0000 0001 0668 7884Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, 3000 Leuven, Belgium
| | - Johan Nuyts
- grid.5596.f0000 0001 0668 7884Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, 3000 Leuven, Belgium ,Nuclear Medicine and Molecular Imaging, Medical Imaging Research Center, 3000 Leuven, Belgium
| | - Jan Wouters
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium
| | - Robert A. McLaughlin
- grid.1010.00000 0004 1936 7304Australian Research Council Centre of Excellence for Nanoscale BioPhotonics, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1010.00000 0004 1936 7304Institute for Photonics and Advanced Sensing, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1012.20000 0004 1936 7910School of Engineering, University of Western Australia, Perth, WA 6009 Australia
| | - Nicolas Verhaert
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium ,grid.410569.f0000 0004 0626 3338Department of Otorhinolaryngology, Head and Neck Surgery, University Hospitals of Leuven, 3000 Leuven, Belgium
| |
Collapse
|
8
|
Croner AM, Heshmat A, Schrott-Fischer A, Glueckert R, Hemmert W, Bai S. Effects of Degrees of Degeneration on the Electrical Excitation of Human Spiral Ganglion Neurons Based on a High-Resolution Computer Model. Front Neurosci 2022; 16:914876. [PMID: 35873813 PMCID: PMC9298973 DOI: 10.3389/fnins.2022.914876] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/13/2022] [Indexed: 11/13/2022] Open
Abstract
After hearing loss retrograde degeneration of spiral ganglion neurons (SGNs) has been described. Studies modeling the effects of degeneration mostly omitted peripheral processes (dendrites). Recent experimental observations indicated that degenerating SGNs manifested also a reduced diameter of their dendrites. We simulated populations of 400 SGNs inside a high resolution cochlear model with a cochlear implant, based on μCT scans of a human temporal bone. Cochlear implant stimuli were delivered as biphasic pulses in a monopolar configuration. Three SGN situations were simulated, based on our previous measurements of human SGN dendrites: (A) SGNs with intact dendrites (before degeneration), (B) degenerating SGNs, dendrites with a smaller diameter but original length, (C) degenerating SGNs, dendrites omitted. SGN fibers were mapped to characteristic frequency, and place pitch was estimated from excitation profiles. Results from degenerating SGNs (B, C) were similar. Most action potentials were initiated in the somatic area for all cases (A, B, C), except for areas near stimulating electrodes in the apex with intact SGNs (A), where action potentials were initiated in the distal dendrite. In most cases, degenerating SGNs had lower thresholds than intact SGNs (A) (down to -2 dB). Excitation profiles showed increased ectopic activation, i.e., activation of unintended neuronal regions, as well as similar neuronal regions excited by different apical electrodes, for degenerating SGNs (B, C). The estimated pitch showed cases of pitch reversals in apical electrodes for intact SGNs (A), as well as mostly identical pitches evoked by the four most apical electrodes for degenerating SGNs (B, C). In conclusion, neuronal excitation profiles to electrical stimulation exhibited similar traits in both ways of modeling SGN degeneration. Models showed degeneration of dendrites caused increased ectopic activation, as well as similar excitation profiles and pitch evoked by different apical electrodes. Therefore, insertion of electrodes beyond approximately 450° may not provide any benefit if SGN dendrites are degenerated.
Collapse
Affiliation(s)
- Albert M Croner
- Department of Electrical and Computer Engineering, Technical University of Munich, Munich, Germany.,Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
| | - Amirreza Heshmat
- Laboratory for Inner Ear Biology, Medical University of Innsbruck, Innsbruck, Austria
| | | | - Rudolf Glueckert
- Laboratory for Inner Ear Biology, Medical University of Innsbruck, Innsbruck, Austria
| | - Werner Hemmert
- Department of Electrical and Computer Engineering, Technical University of Munich, Munich, Germany.,Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
| | - Siwei Bai
- Department of Electrical and Computer Engineering, Technical University of Munich, Munich, Germany.,Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
| |
Collapse
|
9
|
Dohr D, Wulf K, Grabow N, Mlynski R, Schraven SP. A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds. MATERIALS 2022; 15:ma15093049. [PMID: 35591381 PMCID: PMC9104964 DOI: 10.3390/ma15093049] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/14/2022] [Accepted: 04/14/2022] [Indexed: 01/27/2023]
Abstract
To prevent endocochlear insertion trauma, the development of drug delivery coatings in the field of CI electrodes has become an increasing focus of research. However, so far, the effect of a polymer coating of PLLA on the mechanical properties, such as the insertion pressure and friction of an electrode array, has not been investigated. In this study, the insertion pressure of a PLLA-coated, 31.5-mm long standard electrode array was examined during placement in a linear cochlear model. Additionally, the friction coefficients between a PLLA-coated electrode array and a tissue simulating the endocochlear lining were acquired. All data were obtained at different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s) and compared with those of an uncoated electrode array. It was shown that both the maximum insertion pressure generated in the linear model and the friction coefficient of the PLLA-coated electrode did not depend on the insertion speed. At higher insertion speeds above 1.0 mm/s, the insertion pressure (1.268 ± 0.032 mmHg) and the friction coefficient (0.40 ± 0.15) of the coated electrode array were similar to those of an uncoated array (1.252 ± 0.034 mmHg and 0.36 ± 0.15). The present study reveals that a PLLA coating on cochlear electrode arrays has a negligible effect on the electrode array insertion pressure and the friction when higher insertion speeds are used compared with an uncoated electrode array. Therefore, PLLA is a suitable material to be used as a coating for CI electrode arrays and can be considered for a potential drug delivery system.
Collapse
Affiliation(s)
- Dana Dohr
- Department of Otorhinolaryngology, Head and Neck Surgery “Otto Körner”, Rostock University Medical Center, 18057 Rostock, Germany; (R.M.); (S.P.S.)
- Correspondence: author
| | - Katharina Wulf
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany; (K.W.); (N.G.)
| | - Niels Grabow
- Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany; (K.W.); (N.G.)
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery “Otto Körner”, Rostock University Medical Center, 18057 Rostock, Germany; (R.M.); (S.P.S.)
| | - Sebastian P. Schraven
- Department of Otorhinolaryngology, Head and Neck Surgery “Otto Körner”, Rostock University Medical Center, 18057 Rostock, Germany; (R.M.); (S.P.S.)
| |
Collapse
|
10
|
Transimpedance Matrix Measurements Reliably Detect Electrode Tip Fold-over in Cochlear Implantation. Otol Neurotol 2021; 42:e1494-e1502. [PMID: 34766947 DOI: 10.1097/mao.0000000000003334] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE During cochlear implantation, electrophysiological tests are performed to document safe technical functioning of implant and electrodes. In rare cases, the apical part of the electrode folds over during insertion. The data from transimpedance matrix (TIM) measurements enable the generation of a heat map or TIM profile measuring the spatial distribution of voltage. The aim of this study was to determine the accuracy of heat-map TIM profiles and compare them with spread of excitation (SOE) measurements and intraoperative imaging for prediction of electrode malposition. STUDY DESIGN Non-randomized study. SETTING Tertiary referral center. PATIENTS AND INTERVENTIONS One hundred patients who underwent cochlear implantation with completed TIM measurements, SOE data and perioperative imaging met the inclusion criteria and were enrolled. MAIN OUTCOME MEASURE The electrophysiological data on the electrode array positioning was compared with temporal bone imaging. RESULTS In seven cases, TIM measurements showed irregular results. In two cases, irregular TIM profiles were registered, but SOE data and 3D x-ray of the temporal bone didn't display deviated electrode positioning. A 3D x-ray of the skull displayed electrode tip fold-over in four cases and electrode buckling in one case. Sensitivity of TIM measurements and SOE data was 100%, specificity of TIM measurements was 97.89%, and specificity of SOE data was 98.93%. CONCLUSION Out of 100 patients using TIM measurements for detection of electrode malpositioning, no false negative cases were detected. TIM measurements successfully detect electrode malposition in an intraoperative setting. Different heat map patterns may be observed depending on location and type of malposition.
Collapse
|
11
|
Hendricks CM, Cavilla MS, Usevitch DE, Bruns TL, Riojas KE, Leon L, Webster RJ, Warren FM, Abbott JJ. Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro. Otol Neurotol 2021; 42:1022-1030. [PMID: 33859137 PMCID: PMC8282696 DOI: 10.1097/mao.0000000000003129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS Undesirable forces applied to the basilar membrane during surgical insertion of lateral-wall cochlear-implant electrode arrays (EAs) can be reduced via robotic insertion with magnetic steering of the EA tip. BACKGROUND Robotic insertion of magnetically steered lateral-wall EAs has been shown to reduce insertion forces in vitro and in cadavers. No previous study of robot-assisted insertion has considered force on the basilar membrane. METHODS Insertions were executed in an open-channel scala-tympani phantom. A force plate, representing the basilar membrane, covered the channel to measure forces in the direction of the basilar membrane. An electromagnetic source generated a magnetic field to steer investigational EAs with permanent magnets at their tips, while a robot performed the insertion. RESULTS When magnetic steering was sufficient to pull the tip of the EA off of the lateral wall of the channel, it resulted in at least a 62% reduction of force on the phantom basilar membrane at insertion depths beyond 14.4 mm (p < 0.05), and these beneficial effects were maintained beyond approximately the same depth, even with 10 degrees of error in the estimation of the modiolar axis of the cochlea. When magnetic steering was not sufficient to pull the EA tip off of the lateral wall, a significant difference from the no-magnetic-steering case was not found. CONCLUSIONS This in vitro study suggests that magnetic steering of robotically inserted lateral-wall cochlear-implant EAs, given sufficient steering magnitude, can reduce forces on the basilar membrane in the first basilar turn compared with robotic insertion without magnetic steering.
Collapse
Affiliation(s)
- Cameron M Hendricks
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - Matt S Cavilla
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - David E Usevitch
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - Trevor L Bruns
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Katherine E Riojas
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | | | - Robert J Webster
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | | | - Jake J Abbott
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| |
Collapse
|
12
|
Li J, Wu Y, Zhuo J, Wang Z. Modeling and simulation of cochlear perimodiolar electrode based on composite spring-mass model. Comput Methods Biomech Biomed Engin 2021; 25:290-297. [PMID: 34263671 DOI: 10.1080/10255842.2021.1950145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
This paper proposes, a method for the physical modeling of the perimodiolar electrode, particularly for the process of recovering its preset shape with the guide wire drawn out, based on the composite spring-mass model by employing the virtual-volumetric spring inspired from the traditional spring-mass model. Simulation experiments of modeling and virtual insertion of perimodiolar electrode were carried out. The results indicated that the mean and standard deviation of the difference between the local deformation angles of the simulated and measured sets of mass points, (1, 2, 3), (2, 3, 4), …, (13, 14, 15), were 6.34° and 5.98°, respectively. Additionally, the physical model of the perimodiolar electrode can reflect the overall morphological changes of the real perimodiolar electrode.
Collapse
Affiliation(s)
- Jianjun Li
- College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
| | - Yue Wu
- College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
| | - Jianye Zhuo
- College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
| | - Zuo Wang
- College of Artificial Intelligence and Innovation, Ma'anshan University, Ma'anshan, China
| |
Collapse
|
13
|
Frictional Behavior of Cochlear Electrode Array Is Dictated by Insertion Speed and Impacts Insertion Force. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11115162] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Background: During cochlear implantation, the electrode array has significant friction with the sensitive endocochlear lining and causes mutual mechanical trauma while the array is being inserted. Both, the impact of insertion speed on electrode friction and the relationship of electrode insertion force and friction have not been adequately investigated to date. Methods: In this study, friction coefficients between a CI electrode array (31.5 mm) and a tissue simulating the endocochlear lining have been acquired, depending on different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s). Additionally, the electrode insertion forces during the placing into a scala tympani model were recorded and correlated with the friction coefficient. Results: It was shown that the friction coefficient reached the lowest value at an insertion speed of 0.1 mm/s (0.24 ± 0.13), a maximum occurred at 1.5 mm/s (0.59 ± 0.12), and dropped again at 2 mm/s (0.45 ± 0.11). Similar patterns were observed for the insertion forces. Consequently, a high correlation coefficient (0.9) was obtained between the insertion forces and friction coefficients. Conclusion: The present study reveals a non-linear increase in electrode array friction, when insertion speed raises and reports a high correlation between friction coefficient and electrode insertion force. This dependence is a relevant future parameter to evaluate and reduce cochlear implant insertion trauma. Significance statement: Here, we demonstrated a dependence between cochlear electrode insertion speed and its friction behavior and a high correlation to insertion force. Our study provides valuable information for the evaluation and prevention of cochlear implant insertion trauma and supports the optimization of cochlear electrode arrays regarding friction characteristics.
Collapse
|
14
|
Du Q, Wang C, He G, Sun Z. Insertion trauma of a new cochlear implant electrode: evaluated by histology in fresh human temporal bone specimens. Acta Otolaryngol 2021; 141:490-494. [PMID: 33784954 DOI: 10.1080/00016489.2021.1897159] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND Combining acoustic and electrical stimulation has been successfully used in patients with low-frequency residual hearing. Electrode insertion trauma, such as electrode translocation could result in loss of residual hearing. OBJECTIVES The aim of the study is to evaluate the LCI-20PI electrode array insertion trauma to the intra-cochlear structures in fresh human temporal bone specimens. MATERIALS AND METHODS The LCI-20PI electrode arrays were inserted into scalae tympani through round window membrane in 10 cochleae from ten fresh human cadavers. The intracochlear trauma was evaluated histologically by a scale of 0-4: 0 - no observable trauma, 1 - elevation of basilar membrane, 2 - rupture of basilar membrane or spiral ligament, 3-dislocation into scala vestibuli and 4 - fracture of modiolus or osseous spiral lamina. The insertion depth was measured by radiography. RESULTS Histological results revealed no observable trauma in seven specimens; basal membrane elevation and rupture in two specimens; the electrode array misled into scala vestibuli in one specimen. The insertion depth varied from 228° to 288°. CONCLUSIONS AND SIGNIFICANCE The insertion of the LCI-20PI electrode arrays caused no trauma in the majority of the fresh temporal bone specimens. No translocation of the electrode arrays from the scala tympani to the scala vestibuli was observed.
Collapse
Affiliation(s)
- Qiang Du
- ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, PR China
- NHC Key Laboratory of Hearing Medicine, Fudan University, Shanghai, PR China
- Shanghai Hearing Medical Center, Shanghai, PR China
| | - Cheng Wang
- Shanghai Engineering Research Center of Cochlear Implants, Shanghai, PR China
| | - Guangming He
- Shanghai Engineering Research Center of Cochlear Implants, Shanghai, PR China
| | - Zengjun Sun
- Shanghai Engineering Research Center of Cochlear Implants, Shanghai, PR China
| |
Collapse
|
15
|
Eisenhut F, Lang S, Taha L, Hoelter P, Wiesmueller M, Uder M, Iro H, Doerfler A, Hornung J. Identification of anatomic risk factors for scalar translocation in cochlear implant patients. Z Med Phys 2021; 31:254-264. [PMID: 33648794 DOI: 10.1016/j.zemedi.2021.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 12/02/2020] [Accepted: 01/05/2021] [Indexed: 10/22/2022]
Abstract
AIM Microanatomical evaluation of cochlear implant (CI) patients to identify anatomical risk factors for a scalar translocation. METHODS CI patients with both a regular scala tympani spiralization (group A) and a scalar translocation (group B) were identified via postoperative flat-detector computed tomography (FD-CT). Then, the corresponding preoperative multislice computed tomography (MS-CT) and postoperative FD-CT datasets were assessed: First, the cochleae were separated in 6 segments of 45° each. Next, quantitative (cochlea height, length, depth, cochlear duct diameter [CD] per segment; percentual tapering of the CD per segment named cochlear geometry index [CGI]) and qualitative (identifiability of the CI model; CI-integrity; intracochlear array position) parameters were evaluated and compared for both groups. Receiver-operating-characteristics (ROC) analysis was performed for the CGI. RESULTS In total, 40 preoperative MS-CT and postoperative FD-CT datasets (nA=20; nB=20) were analysed. Model "CI 512" was successfully identified and CI-integrity has been confirmed in all cases. Quantitative analysis showed a significant difference of both the CD at 0° (CDA0°= 2.06± 0.23mm; CDB0°= 2.19±0.18mm; p0°= 0.04) and the CGI of the first segment (CGIA0°-45°= 18.87±6.04%; CGIB0°-45°= 28.89±8.58%; p0°-45°= 0.0001). For all other 5 cochlear segments there was no significant difference of CD and CGI; there was no significant difference of external cochlea diameters. The area under the curve (AUC) of the CGI0-45° was 0.864 with 24.50° as the optimal cut-off value to discriminate patients with a scala tympani spiralization and a scalar translocation. CGI0-45° of> 24.50° allowed the correct identification of 85% of patients with a scalar translocation. CONCLUSION CI insertion trauma is associated with a significantly higher narrowing of the proximal basal cochlea turn (BCT). The CGI as percentual tapering of the BCT turned out as reliable, clinically applicable parameter for identification of patients with an increased risk for a scalar translocation.
Collapse
Affiliation(s)
- Felix Eisenhut
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany.
| | - Stefan Lang
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Lava Taha
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| | - Philip Hoelter
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Marco Wiesmueller
- Institute of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Heinrich Iro
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| | - Arnd Doerfler
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Joachim Hornung
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| |
Collapse
|
16
|
Jwair S, Prins A, Wegner I, Stokroos RJ, Versnel H, Thomeer HGXM. Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays - A Meta-Analysis. Laryngoscope 2020; 131:1358-1368. [PMID: 33159469 PMCID: PMC8246990 DOI: 10.1002/lary.29224] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/15/2022]
Abstract
Objectives/Hypothesis Two types of electrode arrays for cochlear implants (CIs) are distinguished: lateral wall and perimodiolar. Scalar translocation of the array can lead to intracochlear trauma by penetrating from the scala tympani into the scala vestibuli or scala media, potentially negatively affecting hearing performance of CI users. This systematic review compares the lateral wall and perimodiolar arrays with respect to scalar translocation. Study Design Systematic review. Methods PubMed, Embase, and Cochrane databases were reviewed for studies published within the last 11 years. No other limitations were set. All studies with original data that evaluated the occurrence of scalar translocation or tip fold‐over (TF) with postoperative computed tomography (CT) following primary cochlear implantation in bilateral sensorineuronal hearing loss patients were considered to be eligible. Data were extracted independently by two reviewers. Results We included 33 studies, of which none were randomized controlled trials. Meta‐analysis of five cohort studies comparing scalar translocation between lateral wall and perimodiolar arrays showed that lateral wall arrays have significantly lower translocation rates (7% vs. 43%; pooled odds ratio = 0.12). Translocation was negatively associated with speech perception scores (weighted mean 41% vs. 55%). Tip fold‐over of the array was more frequent with perimodiolar arrays (X2 = 6.8, P < .01). Conclusions Scalar translocation and tip fold‐overs occurred more frequently with perimodiolar arrays than with lateral wall arrays. In addition, translocation of the array negatively affects hearing with the cochlear implant. Therefore, if one aims to minimize clinically relevant intracochlear trauma, lateral wall arrays would be the preferred option for cochlear implantation. Laryngoscope, 131:1358–1368, 2021
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Adrianus Prins
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Inge Wegner
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Robert J Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Hans G X M Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
17
|
Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography. Eur Arch Otorhinolaryngol 2020; 278:1381-1386. [PMID: 32671538 PMCID: PMC8057993 DOI: 10.1007/s00405-020-06198-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 07/07/2020] [Indexed: 12/27/2022]
Abstract
Purpose Cone Beam Computed Tomography (CBCT) offers a valid alternative to conventional Computed Tomography (CT). A possible radiation dose reduction with the use of CBCT in postoperative imaging of CIs is of great importance. Whether the visualization of Cochlear Implant (CI) electrodes in CBCT correlates with the radiation dose applied was investigated in this study. Methods We compared the visualization quality of Contour Advance CIs to Straight CIs from Cochlear using CBCT with varying tube parameters on whole-head specimen. Results The internal diameter of the cochlea decreases from base to apex, resulting in a significantly different intracochlear positioning of the two tested CI models. While electrodes of the Contour Advance series are located close to the modiolus, thus closer to the spiral ganglion neurons, those of the Straight series are located further away. The artifact portion of the electrode amounts to 50–70% of the radiological diameter of the electrode. An increase in artifact portion from the base (electrode #1 approx. 50%) to the apex (electrode #20 approx. 70%) of the cochlea was observed. The visualization of electrodes in the medial and apical part of the cochlea is limited due to artifact overlapping. There was no correlation between the artifact size and the applied radiation dose. Conclusion The results indicate that a reduction of the radiation dose by up to 45% of the currently applied radiation dose of standard protocols would be possible. Investigations of the effects on subjective image quality still need to be performed.
Collapse
|
18
|
Perez E, Viziano A, Al-Zaghal Z, Telischi FF, Sangaletti R, Jiang W, Dietrich WD, King C, Hoffer ME, Rajguru SM. Anatomical Correlates and Surgical Considerations for Localized Therapeutic Hypothermia Application in Cochlear Implantation Surgery. Otol Neurotol 2020; 40:1167-1177. [PMID: 31318786 PMCID: PMC6750193 DOI: 10.1097/mao.0000000000002373] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Application of localized, mild therapeutic hypothermia during cochlear implantation (CI) surgery is feasible for residual hearing preservation.
Collapse
Affiliation(s)
| | - Andrea Viziano
- Department of Otolaryngology.,Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, Rome, Italy
| | | | | | | | - Weitao Jiang
- Department of Biomedical Engineering, University of Miami, Miami, Florida
| | - William Dalton Dietrich
- Department of Neurological Surgery, The Miami Project to Cure Paralysis, University of Miami, Miami, Florida
| | | | | | - Suhrud M Rajguru
- Department of Otolaryngology.,Department of Biomedical Engineering, University of Miami, Miami, Florida
| |
Collapse
|
19
|
Bruns TL, Riojas KE, Ropella DS, Cavilla MS, Petruska AJ, Freeman MH, Labadie RF, Abbott JJ, Webster RJ. Magnetically Steered Robotic Insertion of Cochlear-Implant Electrode Arrays: System Integration and First-In-Cadaver Results. IEEE Robot Autom Lett 2020; 5:2240-2247. [PMID: 34621979 DOI: 10.1109/lra.2020.2970978] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cochlear-implant electrode arrays (EAs) must be inserted accurately and precisely to avoid damaging the delicate anatomical structures of the inner ear. It has previously been shown on the benchtop that using magnetic fields to steer magnet-tipped EAs during insertion reduces insertion forces, which correlate with insertion errors and damage to internal cochlear structures. This paper presents several advancements toward the goal of deploying magnetic steering of cochlear-implant EAs in the operating room. In particular, we integrate image guidance with patient-specific insertion vectors, we incorporate a new nonmagnetic insertion tool, and we use an electromagnetic source, which provides programmable control over the generated field. The electromagnet is safer than prior permanent-magnet approaches in two ways: it eliminates motion of the field source relative to the patient's head and creates a field-free source in the power-off state. Using this system, we demonstrate system feasibility by magnetically steering EAs into a cadaver cochlea for the first time. We show that magnetic steering decreases average insertion forces, in comparison to manual insertions and to image-guided robotic insertions alone.
Collapse
Affiliation(s)
- Trevor L Bruns
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Katherine E Riojas
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Dominick S Ropella
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Matt S Cavilla
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Andrew J Petruska
- Department of Mechanical Engineering, Colorado School of Mines, Golden, CO, USA
| | - Michael H Freeman
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jake J Abbott
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Robert J Webster
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
20
|
Abstract
HYPOTHESIS We hypothesize that human cases of cochlear implantation (CI) with folding of the electrode array will demonstrate greater degrees of intracochlear ossification, lower spiral ganglion neuron (SGN) counts, and poorer audiometric outcomes. BACKGROUND CI electrode array folding, such folding of the proximal array, is a relatively common surgical complication that can occur with forceful electrode insertion and may be an important and avoidable factor affecting implant outcomes. However, otopathologic findings and audiologic outcomes of human cases where folding of the implant electrode array is observed remain undefined. METHODS Specimens from a human temporal bone repository having undergone CI during life were evaluated. Specimens with folding of the electrode array on histological analysis constituted study cases. Electrode-matched specimens without array folding constituted controls. All specimens were examined by light microscopy and histopathologically described. Intracochlear fibrosis and osseous tissue, and SGN counts were measured. Pre- and postoperative word recognition scores were also compared. RESULTS Cases with folded electrodes showed greater volumes of intracochlear osseous tissue than controls, which was most prominent in areas adjacent to array folding. Both cases and controls demonstrated similar amounts of fibrous tissue. Folded cases showed decreased SGNs when compared with the contralateral ear, whereas controls showed stable SGN populations between ears. In this small cohort, postoperative hearing outcomes were similar between groups. CONCLUSION Atypical fibro-osseous changes and lower SGN counts are observed in cases of CI electrode folding. Future studies are necessary to determine if recognition and correction of folding can prevent long-term intracochlear changes.
Collapse
|
21
|
Jang J, Kim J, Kim YC, Kim S, Chou N, Lee S, Choung Y, Kim S, Brugger J, Choi H, Jang JH. A 3D Microscaffold Cochlear Electrode Array for Steroid Elution. Adv Healthc Mater 2019; 8:e1900379. [PMID: 31532887 DOI: 10.1002/adhm.201900379] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 09/04/2019] [Indexed: 11/05/2022]
Abstract
In cochlear implants, the electrode insertion trauma during surgery can cause damage residual hearing. Preserving the residual hearing is an important challenge and the localized administration of drugs, such as steroids, is one of the most promising ways, but remains a challenge. Here, a microscaffold cochlear electrode array (MiSCEA) consisting of a microfabricated flexible electrode array and a 3D microscaffold for steroid reservoir is reported. The MiSCEA without loaded drug is tested by measuring the electrically evoked auditory brainstem response of the cochlea in guinea pigs (n = 4). The scaffold is then coated with steroid (dexamethasone) encapsulated in polylactic-co-glycolic acid and the continuous release of the steroid into artificial perilymph during six weeks is monitored. The steroid-containing scaffolds are then implanted into guinea pigs (n = 4) and threshold shifts are analyzed for four weeks by measuring the acoustically evoked auditory brainstem response. The threshold shifts tend to be lower in the group implanted with the steroid-containing MiSCEAs. The feasibility of 3D MiSCEA opens up the development of potential next-generation cochlear electrode with improved steroid release dynamics into cochlea.
Collapse
Affiliation(s)
- Jongmoon Jang
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
- DGIST‐ETH Microrobot Research CenterDGIST Daegu 42988 Republic of Korea
- Microsystem LaboratoryÉcole Polytechnique Fédérale de Lausanne (EPFL) Lausanne CH‐1015 Switzerland
| | - Jin‐young Kim
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
- DGIST‐ETH Microrobot Research CenterDGIST Daegu 42988 Republic of Korea
| | - Yeong Cheol Kim
- Department of OtolaryngologyAjou University School of Medicine Suwon 16499 Republic of Korea
- Department of Biomedical SciencesBK21 Plus Research Center for Biomedical SciencesAjou University Graduate School of Medicine Suwon 16499 Republic of Korea
| | - Sangwon Kim
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
- DGIST‐ETH Microrobot Research CenterDGIST Daegu 42988 Republic of Korea
| | - Namsun Chou
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
| | - Seungmin Lee
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
- DGIST‐ETH Microrobot Research CenterDGIST Daegu 42988 Republic of Korea
| | - Yun‐Hoon Choung
- Department of OtolaryngologyAjou University School of Medicine Suwon 16499 Republic of Korea
- Department of Biomedical SciencesBK21 Plus Research Center for Biomedical SciencesAjou University Graduate School of Medicine Suwon 16499 Republic of Korea
| | - Sohee Kim
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
| | - Juergen Brugger
- Microsystem LaboratoryÉcole Polytechnique Fédérale de Lausanne (EPFL) Lausanne CH‐1015 Switzerland
| | - Hongsoo Choi
- Department of Robotics EngineeringDaegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu 42988 Republic of Korea
- DGIST‐ETH Microrobot Research CenterDGIST Daegu 42988 Republic of Korea
| | - Jeong Hun Jang
- Department of OtolaryngologyAjou University School of Medicine Suwon 16499 Republic of Korea
| |
Collapse
|
22
|
Rebscher S, Zhou DD, Zeng FG. Development and Clinical Introduction of the Nurotron Cochlear Implant Electrode Array. J Int Adv Otol 2019; 14:392-400. [PMID: 30644380 DOI: 10.5152/iao.2018.6285] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
As the only medical device used in the treatment for deafness, the cochlear implant has benefited to more than half a million individuals worldwide. However, the device has limited penetration due to its high cost, especially in low- and middle-income countries. China alone has 27.8 million deaf people, but less than 100,000 of them have received a cochlear implant. The Nurotron Venus device was developed to address the need for an affordable yet safe and effective cochlear implant. The present study describes the design, development, and evaluation of the Nurotron intracochlear electrode array. The standard array is 22 mm in length from the round window marker to the apical tip of the carrier and has 24 electrodes, with a surface area of 0.32 mm2 and center-to-center spacing of 0.85 mm. The Nurotron array has been tested to meet the mechanical, chemical, and electrical requirements specified by the ISO Standard 14708-07. Human temporal bone and clinical trial results showed that the Nurotron array is easy to insert (7.8/10 rating with 10 indicating the highest ease of use) and has a low complication rate (12.5%) of severe insertion trauma while achieving high device stability and reliability (6 array failures in 43,000 patient years of experience). As a critical component, the Nurotron array has contributed to the high level of Nurotron implant speech performance, equivalent to that produced by other existing devices. The Nurotron device has benefited 10,000 deaf people and helped reduce the unit cost from US$25,000 in 2011 to US$4,620 in 2017 through the Chinese Government Tender Program. New, slim, and micromachined electrodes are being developed to further improve performance and accessibility.
Collapse
Affiliation(s)
- Stephen Rebscher
- Department of Otolaryngology, University of California San Francisco, San Francisco, USA
| | | | - Fan-Gang Zeng
- Department of Otolaryngology, University of California Irvine, Irvine, USA
| |
Collapse
|
23
|
Abstract
OBJECTIVES In an attempt to improve spectral resolution and speech intelligibility, several current focusing methods have been proposed to increase spatial selectivity by decreasing intracochlear current spread. For example, tripolar stimulation administers current to a central electrode and uses the two flanking electrodes as the return pathway, creating a narrower intracochlear electrical field and hence increases spectral resolution when compared with monopolar (MP) stimulation. However, more current is required, and in some patients, specifically the ones with high electrode impedances, full loudness growth cannot be supported because of compliance limits. The present study describes and analyses a new loudness encoding approach that uses tripolar stimulation near threshold and gradually broadens the excitation (by decreasing compensation coefficient σ) to increase loudness without the need to increase overall current. It is hypothesized that this dynamic current focusing (DCF) strategy increases spatial selectivity, especially at lower loudness levels, while maintaining maximum selectivity at higher loudness levels, without reaching compliance limits. DESIGN Eleven adult cochlear implant recipients with postlingual hearing loss, with at least 9 months of experience with their HiRes90K implant, were selected to participate in this study. Baseline performance regarding speech intelligibility in noise (Dutch matrix sentence test), spectral ripple discrimination at 45 and 65 dB, and temporal modulation detection thresholds were assessed using their own clinical program, fitted on a Harmony processor. Subsequently, the DCF strategy was fitted on a research Harmony processor. Threshold levels were determined with σ = 0.8, which means 80% of current is returned to the flanking electrodes and the remaining 20% to the extracochlear ground electrode. Instead of increasing overall pulse magnitude, σ was decreased to determine most comfortable loudness. After 2 to 3 hr of adaptation to the research strategy, the same psychophysical measures were taken. RESULTS At 45 dB, average spectral ripple scores improved significantly from 2.4 ripples per octave with their clinical program to 3.74 ripples per octave with the DCF strategy (p = 0.016). Eight out of 11 participants had an improved spectral resolution at 65 dB. Nevertheless, no significant difference between DCF and MP was observed at higher presentation levels. Both speech-in-noise and temporal modulation detection thresholds were equal for MP and DCF strategies. Subjectively, 2 participants preferred the DCF strategy over their own clinical program, 2 preferred their own strategy, while the majority of the participants had no preference. Battery life was decreased and ranged from 1.5 to 4 hr. CONCLUSIONS The DCF strategy gives better spectral resolution, at lower loudness levels, but equal performance on speech tests. These outcomes warrant for a longer adaptation period to study long-term outcomes and evaluate if the outcomes in the ripple tests transfer to the speech scores. Further research, for example, with respect to fitting rules and reduction of power consumption, is necessary to make the DCF strategy suitable for routine clinical application.
Collapse
|
24
|
Theoretical Evaluation and Experimental Validation of Localized Therapeutic Hypothermia Application to Preserve Residual Hearing After Cochlear Implantation. Ear Hear 2019; 39:712-719. [PMID: 29240567 DOI: 10.1097/aud.0000000000000529] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Cochlear implantation surgery has been shown to result in trauma to inner ear sensory structures, resulting in loss of residual hearing. Localized therapeutic hypothermia has been shown in clinical care to be a neuroprotective intervention. Previously, we have shown in an experimental model that localized hypothermia protects cochlear hair cells and residual hearing function against surgical and cochlear implantation trauma. Using experimental temperature measurements carried out in human cadaver temporal bones and a finite element model of the inner ear, the present study examined the temperature distribution of a custom-designed hypothermia delivery system in the human inner ear organs. DESIGN The efficacy of the hypothermia probe and resulting heat distribution across human cochlea and surrounding tissues were modeled in three-dimensional in COMSOL. The geometry and dimensions of inner ear and temporal bones were derived from computed tomographic and magnetic resonance imaging images. Model predictions were compared with experimental observations from five human temporal bones. RESULTS In both the modeling and experimental studies, the cochlear temperature was lowered by 4 to 6 °C on the round window from a baseline of 37 °C within 16 to 18 minutes. The model simulations showed uniformly distributed cooling across the cochlea. This study provides insight for design, operation, and protocols for efficacious delivery of mild therapeutic hypothermia to the human cochlea that may significantly benefit patients undergoing surgical cochlear implantation by preserving residual hearing. CONCLUSION There was a close correlation between the results of the numerical simulations and experimental observations in this study. Our custom-designed system is capable of effectively providing mild therapeutic hypothermia locally to the human cochlea. When combined with results from in vivo animal experiments, the present study suggests that the application of localized therapeutic hypothermia may hold potential for patients with an aim to preserve residual hearing after cochlear implantation.
Collapse
|
25
|
Abstract
OBJECTIVE It is known that the insertion of the intracochlear electrode is critical procedure because the damage around cochlear structures can deteriorate hearing restoration. To reduce the trauma during the electrode insertion surgery, we developed a thin and flexible intracochlear electrode array constructed with carbon nanotube (CNT) bundles. METHODS Each CNT bundle was used for an individual electrode channel after coated with parylene C for insulation. By encapsulating eight CNT bundles with silicone elastomer, an 8-channel intracochlear electrode array was fabricated. The mechanical and electrochemical characteristics were assessed to evaluate the flexibility and feasibility of the electrode as a stimulation electrode. The functionality of the electrode was confirmed by electrically evoked auditory brainstem responses (eABR) recorded from a rat. RESULTS The proposed electrode has a thickness of 135 μm at the apex and 395 μm at the base. It was demonstrated that the CNT bundle-based electrodes require 6-fold the lower insertion force than metal wire-based electrodes. The electrode impedance and the cathodic charge storage capacitance (CSCc) were 2.70 kΩ ∠-20.4° at 1 kHz and - 708 mC/cm2, respectively. The eABR waves III and V were observed when stimulation current is greater than 50 μA. CONCLUSION A thin and flexible CNT bundle-based intracochlear electrode array was successfully developed. The feasibility of the proposed electrode was shown in terms of mechanical and electrochemical characteristics. A proposed CNT bundle-based intracochlear electrode may reduce the risk of trauma during electrode insertion surgery.
Collapse
|
26
|
Downing M. Electrode Designs for Protection of the Delicate Cochlear Structures. J Int Adv Otol 2019; 14:401-403. [PMID: 30644381 DOI: 10.5152/iao.2018.6461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The most recent electrode introductions from Advanced Bionics, the HiFocus™ Mid-Scala and the HiFocus SlimJ arrays, have common design goals intended to provide sufficient access to the necessary frequency range while avoiding intracochlear trauma. The electrode choice, either a pre-curved (mid-scala) array or straight (lateral) array, can be made by the surgeon based on anatomical considerations and/or their preferred surgical approach. Both arrays offer ease of handling, suitability for a round window and cochleostomy based insertion and control of the insertion speed.
Collapse
|
27
|
Shepherd RK, Villalobos J, Burns O, Nayagam DAX. The development of neural stimulators: a review of preclinical safety and efficacy studies. J Neural Eng 2018; 15:041004. [PMID: 29756600 PMCID: PMC6049833 DOI: 10.1088/1741-2552/aac43c] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. APPROACH The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. MAIN RESULTS Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess efficacy and, given an appropriate animal model, the safety of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to develop any specialist surgical tooling required. SIGNIFICANCE The pipeline from concept to commercialisation of these devices is long and expensive; careful attention to both device design and its preclinical evaluation will have significant impact on the duration and cost associated with taking a device through to commercialisation. Carefully controlled in vitro and in vivo studies together with ex vivo and human cadaver trials are key components of a thorough preclinical evaluation of any new neural stimulator.
Collapse
Affiliation(s)
- Robert K Shepherd
- Bionics Institute, East Melbourne, Australia. Medical Bionics Department, University of Melbourne, Melbourne, Australia
| | | | | | | |
Collapse
|
28
|
Landry TG, Earle G, Brown JA, Bance ML. Real-time intracochlear imaging of automated cochlear implant insertions in whole decalcified cadaver cochleas using ultrasound. Cochlear Implants Int 2018; 19:255-267. [DOI: 10.1080/14670100.2018.1460024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Thomas G. Landry
- Division of Otolaryngology, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Guy Earle
- Division of Otolaryngology, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Jeremy A. Brown
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Manohar L. Bance
- Department of Neuroscience, University of Cambridge, Cambridge, UK
| |
Collapse
|
29
|
Leon L, Warren FM, Abbott JJ. Optimizing the Magnetic Dipole-Field Source for Magnetically Guided Cochlear-Implant Electrode-Array Insertions. ACTA ACUST UNITED AC 2018; 3. [PMID: 30009274 DOI: 10.1142/s2424905x18500046] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Magnetic guidance of cochlear-implant electrode arrays during insertion has been demonstrated in vitro to reduce insertion forces, which is believed to be correlated to a reduction in trauma. In those prior studies, the magnetic dipole-field source (MDS) was configured to travel on a path that would be coincident with the cochlea's modiolar axis, which was an unnecessary constraint that was useful to demonstrate feasibility. In this paper, we determine the optimal configuration (size and location) of a spherical-permanent-magnet MDS needed to accomplish guided insertions with a 100 mT field strength required at the cochlea, and we provide a methodology to perform such an optimization more generally. Based on computed-tomography scans of 30 human subjects, the MDS should be lateral-to and slightly anterior-to the cochlea with an approximate radius (mean and standard deviation across subjects) of 64 mm and 4.5 mm, respectively. We compare these results to the modiolar configuration and find that the volume of the MDS can be reduced by a factor of five with a 43% reduction in its radius by moving it to the optimal location. We conservatively estimate that the magnetic forces generated by the optimal configuration are two orders of magnitude below the threshold needed to puncture the basilar membrane. Although subject-specific optimal configurations are computed in this paper, a one-size-fits-all version with a radius of approximately 75 mm is more robust to registration error and likely more practical. Finally, we explain how to translate the results obtained to an electromagnetic MDS.
Collapse
Affiliation(s)
- Lisandro Leon
- Department of Mechanical Engineering and the Robotics Center, University of Utah, Salt Lake City, UT, USA.,Sarcos Robotics, Salt Lake City, UT, USA
| | | | - Jake J Abbott
- Department of Mechanical Engineering and the Robotics Center, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
30
|
Variations in cochlear duct shape revealed on clinical CT images with an automatic tracing method. Sci Rep 2017; 7:17566. [PMID: 29242508 PMCID: PMC5730551 DOI: 10.1038/s41598-017-16126-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Accepted: 11/07/2017] [Indexed: 12/27/2022] Open
Abstract
Cochlear size and morphology vary greatly and may influence the course of a cochlear implant electrode array during insertion and its final intra-cochlear position. Detailed insight into these variations is valuable for characterizing each cochlea and offers the opportunity to study possible correlations with surgical or speech perception outcomes. This study presents an automatic tracing method to assess individual cochlear duct shapes from clinical CT images. On pre-operative CT scans of 479 inner ears the cochlear walls were discriminated by interpolating voxel intensities along radial and perpendicular lines within multiplanar reconstructions at 1 degree intervals from the round window. In all 479 cochleas, the outer wall could be traced automatically up to 720 degrees. The inner wall and floor of the scala tympani in 192 cochleas. The shape of the cochlear walls were modelled using a logarithmic spiral function including an offset value. The vertical trajectories of the scala tympani exhibited a non-monotonous spiral slope with specific regions at risk for CI-related insertion trauma, and three slope categories could be distinguished. This presented automatic tracing method allows the detailed description of cochlear morphology and can be used for both individual and large cohort evaluation of cochlear implant patients.
Collapse
|
31
|
Role of Multislice CT Imaging in Predicting the Visibility of the Round Window in Pediatric Cochlear Implantation. Otol Neurotol 2017; 38:1097-1103. [DOI: 10.1097/mao.0000000000001493] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Automated analysis of human cochlea shape variability from segmented μ CT images. Comput Med Imaging Graph 2017; 59:1-12. [DOI: 10.1016/j.compmedimag.2017.04.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Revised: 01/10/2017] [Accepted: 04/04/2017] [Indexed: 12/21/2022]
|
33
|
The utilization of round window membrane surface tension in facilitating slim electrodes insertion during cochlear implantation. Eur Arch Otorhinolaryngol 2017. [DOI: 10.1007/s00405-017-4652-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
34
|
Ishai R, Herrmann BS, Nadol JB, Quesnel AM. The pattern and degree of capsular fibrous sheaths surrounding cochlear electrode arrays. Hear Res 2017; 348:44-53. [PMID: 28216124 DOI: 10.1016/j.heares.2017.02.012] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 01/25/2017] [Accepted: 02/14/2017] [Indexed: 01/12/2023]
Abstract
An inflammatory tissue reaction around the electrode array of a cochlear implant (CI) is common, in particular at the electrode insertion region (cochleostomy) where mechanical trauma often occurs. However, the factors determining the amount and causes of fibrous reaction surrounding the stimulating electrode, especially medially near the perimodiolar location, are unclear. Temporal bone (TB) specimens from patients who had undergone cochlear implantation during life with either Advanced Bionics (AB) Clarion ™ or HiRes90K™ (Sylmar, CA, USA) devices that have a half-band and a pre-curved electrode, or Cochlear ™ Nucleus (Sydney, Australia) device that have a full-band and a straight electrode were evaluated. The thickness of the fibrous tissue surrounding the electrode array of both types of CI devices at both the lower (LB) and upper (UB) basal turns of the cochlea was quantified at three locations: the medial, inferior, and superior aspects of the sheath. Fracture of the osseous spiral lamina and/or marked displacement of the basilar membrane were interpreted as evidence of intracochlear trauma. In addition, post-operative word recognition scores, duration of implantation, and post-operative programming data were evaluated. Seven TBs from six patients implanted with AB devices and five TBs from five patients implanted with Nucleus devices were included. A fibrous capsule around the stimulating electrode array was present in all twelve specimens. TBs implanted with AB device had a significantly thicker fibrous capsule at the medial aspect than at the inferior or superior aspects at both locations (LB and UB) of the cochlea (Wilcoxon signed-ranks test, p < 0.01). TBs implanted with a Nucleus device had no difference in the thickness of the fibrous capsule surrounding the track of the electrode array (Wilcoxon signed-ranks test, p > 0.05). Nine of fourteen (64%) basal turns of the cochlea (LB and UB of seven TBs) implanted with AB devices demonstrated intracochlear trauma compared to two of ten (20%) basal turns of the cochlea (LB and UB of five TBs) with Nucleus devices, (Fisher exact test, p < 0.05). There was no significant correlation between the thickness of the fibrous tissue and the duration of implantation or the word recognition scores (Spearman rho, p = 0.06, p = 0.4 respectively). Our outcomes demonstrated the development of a robust fibrous tissue sheath medially closest to the site of electric stimulation in cases implanted with the AB device electrode, but not in cases implanted with the Nucleus device. The cause of the asymmetric fibrous sheath may be multifactorial including insertional trauma, a foreign body response, and/or asymmetric current flow.
Collapse
Affiliation(s)
- Reuven Ishai
- Department of Otolaryngology, Harvard Medical School, Boston, MA, USA; Department of Otolaryngology, Massachusetts Eye and Ear, Boston, MA, USA
| | - Barbara S Herrmann
- Department of Otolaryngology, Harvard Medical School, Boston, MA, USA; Department of Audiology, Massachusetts Eye and Ear, Boston, MA, USA
| | - Joseph B Nadol
- Department of Otolaryngology, Harvard Medical School, Boston, MA, USA; Department of Otolaryngology, Massachusetts Eye and Ear, Boston, MA, USA
| | - Alicia M Quesnel
- Department of Otolaryngology, Harvard Medical School, Boston, MA, USA; Department of Otolaryngology, Massachusetts Eye and Ear, Boston, MA, USA.
| |
Collapse
|
35
|
Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma. Ear Hear 2017; 38:e168-e179. [DOI: 10.1097/aud.0000000000000394] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
36
|
van der Jagt MA, Briaire JJ, Verbist BM, Frijns JH. Comparison of the HiFocus Mid-Scala and HiFocus 1J Electrode Array: Angular Insertion Depths and Speech Perception Outcomes. Audiol Neurootol 2016; 21:316-325. [DOI: 10.1159/000448581] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 07/20/2016] [Indexed: 11/19/2022] Open
Abstract
The HiFocus Mid-Scala (MS) electrode array has recently been introduced onto the market. This precurved design with a targeted mid-scalar intracochlear position pursues an atraumatic insertion and optimal distance for neural stimulation. In this study we prospectively examined the angular insertion depth achieved and speech perception outcomes resulting from the HiFocus MS electrode array for 6 months after implantation, and retrospectively compared these with the HiFocus 1J lateral wall electrode array. The mean angular insertion depth within the MS population (n = 96) was found at 470°. This was 50° shallower but more consistent than the 1J electrode array (n = 110). Audiological evaluation within a subgroup, including only postlingual, unilaterally implanted, adult cochlear implant recipients who were matched on preoperative speech perception scores and the duration of deafness (MS = 32, 1J = 32), showed no difference in speech perception outcomes between the MS and 1J groups. Furthermore, speech perception outcome was not affected by the angular insertion depth or frequency mismatch.
Collapse
|
37
|
Cochlear Size and Shape Variability and Implications in Cochlear Implantation Surgery. Otol Neurotol 2016; 37:1307-13. [DOI: 10.1097/mao.0000000000001189] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
38
|
Hadler C, Aliuos P, Brandes G, Warnecke A, Bohlmann J, Dempwolf W, Menzel H, Lenarz T, Reuter G, Wissel K. Polymer Coatings of Cochlear Implant Electrode Surface - An Option for Improving Electrode-Nerve-Interface by Blocking Fibroblast Overgrowth. PLoS One 2016; 11:e0157710. [PMID: 27391483 PMCID: PMC4938590 DOI: 10.1371/journal.pone.0157710] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Accepted: 05/03/2016] [Indexed: 11/18/2022] Open
Abstract
Overgrowth of connective tissue and scar formation induced by the electrode array insertion increase the impedance and, thus, diminish the interactions between neural probes as like cochlear implants (CI) and the target tissue. Therefore, it is of great clinical interest to modify the carrier material of the electrodes to improve the electrode nerve interface for selective cell adhesion. On one side connective tissue growth needs to be reduced to avoid electrode array encapsulation, on the other side the carrier material should not compromise the interaction with neuronal cells. The present in vitro-study qualitatively and quantitatively characterises the interaction of fibroblasts, glial cells and spiral ganglion neurons (SGN) with ultrathin poly(N,N-dimethylacrylamide) (PDMAA), poly(2-ethyloxazoline) (PEtOx) and poly([2-methacryloyloxy)ethyl]trimethylammoniumchlorid) (PMTA) films immobilised onto glass surfaces using a photoreactive anchor layer. The layer thickness and hydrophilicity of the polymer films were characterised by ellipsometric and water contact angle measurement. Moreover the topography of the surfaces was investigated using atomic force microscopy (AFM). The neuronal and non-neuronal cells were dissociated from spiral ganglions of postnatal rats and cultivated for 48 h on top of the polymer coatings. Immunocytochemical staining of neuronal and intermediary filaments revealed that glial cells predominantly attached on PMTA films, but not on PDMAA and PEtOx monolayers. Hereby, strong survival rates and neurite outgrowth were only found on PMTA, whereas PDMAA and PEtOx coatings significantly reduced the SG neuron survival and neuritogenesis. As also shown by scanning electron microscopy (SEM) SGN strongly survived and retained their differentiated phenotype only on PMTA. In conclusion, survival and neuritogenesis of SGN may be associated with the extent of the glial cell growth. Since PMTA was the only of the polar polymers used in this study bearing a cationic charge, it can be assumed that this charge favours adhesion of both glial cells and SG neurons glial cells and SGN.
Collapse
Affiliation(s)
- C. Hadler
- Institute for Technical Chemistry, University of Technology Braunschweig, Braunschweig, Germany
| | - P. Aliuos
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing 4 All”, Hannover, Germany
| | - G. Brandes
- Institute of Cell Biology, Center of Anatomy, Hannover Medical School, Hannover, Germany
| | - A. Warnecke
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing 4 All”, Hannover, Germany
| | - J. Bohlmann
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - W. Dempwolf
- Institute for Technical Chemistry, University of Technology Braunschweig, Braunschweig, Germany
| | - H. Menzel
- Institute for Technical Chemistry, University of Technology Braunschweig, Braunschweig, Germany
| | - T. Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing 4 All”, Hannover, Germany
| | - G. Reuter
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - K. Wissel
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- * E-mail:
| |
Collapse
|
39
|
Skinner MW, Holden TA, Whiting BR, Voie AH, Brunsden B, Neely JG, Saxon EA, Hullar TE, Finley CC. In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea. Ann Otol Rhinol Laryngol 2016. [DOI: 10.1177/00034894071160s401] [Citation(s) in RCA: 116] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objectives: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. Methods: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0° start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. Results: The group mean array insertion depth was 477° (range, 286° to 655°). The word scores were negatively correlated (r = −0.59; p = .028) with the number of electrodes in the scala vestibuli. Conclusions: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
Collapse
|
40
|
Skinner MW, Holden TA, Whiting BR, Voie AH, Brunsden B, Neely JG, Saxon EA, Hullar TE, Finley CC. In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea. Ann Otol Rhinol Laryngol 2016. [DOI: 10.1177/000348940711600401] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Objectives: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. Methods: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0° start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. Results: The group mean array insertion depth was 477° (range, 286° to 655°). The word scores were negatively correlated (r = −0.59; p = .028) with the number of electrodes in the scala vestibuli. Conclusions: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
Collapse
|
41
|
Tamames I, King C, Bas E, Dietrich WD, Telischi F, Rajguru SM. A cool approach to reducing electrode-induced trauma: Localized therapeutic hypothermia conserves residual hearing in cochlear implantation. Hear Res 2016; 339:32-9. [PMID: 27260269 DOI: 10.1016/j.heares.2016.05.015] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 05/19/2016] [Accepted: 05/26/2016] [Indexed: 12/31/2022]
Abstract
OBJECTIVE The trauma caused during cochlear implant insertion can lead to cell death and a loss of residual hair cells in the cochlea. Various therapeutic approaches have been studied to prevent cochlear implant-induced residual hearing loss with limited success. In the present study, we show the efficacy of mild to moderate therapeutic hypothermia of 4 to 6 °C applied to the cochlea in reducing residual hearing loss associated with the electrode insertion trauma. APPROACH Rats were randomly distributed in three groups: control contralateral cochleae, normothermic implanted cochleae and hypothermic implanted cochleae. Localized hypothermia was delivered to the middle turn of the cochlea for 20 min before and after implantation using a custom-designed probe perfused with cooled fluorocarbon. Auditory brainstem responses (ABRs) were recorded to assess the hearing function prior to and post-cochlear implantation at various time points up to 30 days. At the conclusion of the trials, inner ears were harvested for histology and cell count. The approach was extended to cadaver temporal bones to study the potential surgical approach and efficacy of our device. In this case, the hypothermia probe was placed next to the round window niche via the facial recess or a myringotomy. MAIN RESULTS A significant loss of residual hearing was observed in the normothermic implant group. Comparatively, the residual hearing in the cochleae receiving therapeutic hypothermia was significantly conserved. Histology confirmed a significant loss of outer hair cells in normothermic cochleae receiving the surgical trauma when compared to the hypothermia treated group. In human temporal bones, a controlled and effective cooling of the cochlea was achieved using our approach. SIGNIFICANCE Collectively, these results suggest that therapeutic hypothermia during cochlear implantation may reduce traumatic effects of electrode insertion and improve conservation of residual hearing.
Collapse
Affiliation(s)
- Ilmar Tamames
- Department of Biomedical Engineering, Seattle, WA, USA
| | | | - Esperanza Bas
- Department of Otolaryngology, University of Miami, Miami, FL, 33136, USA
| | - W Dalton Dietrich
- Department of Neurological Surgery, University of Miami, Miami, FL, 33136, USA
| | - Fred Telischi
- Department of Otolaryngology, University of Miami, Miami, FL, 33136, USA
| | - Suhrud M Rajguru
- Department of Biomedical Engineering, Seattle, WA, USA; Department of Otolaryngology, University of Miami, Miami, FL, 33136, USA.
| |
Collapse
|
42
|
Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion. Biomed Microdevices 2016; 17:32. [PMID: 25681972 DOI: 10.1007/s10544-015-9941-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
An atraumatic cochlear electrode array has become indispensable to high-performance cochlear implants such as electric acoustic stimulation (EAS), wherein the preservation of residual hearing is significant. For an atraumatic implantation, we propose and demonstrate a new improved design of a cochlear electrode array based on liquid crystal polymer (LCP), which can be fabricated by precise batch processes and a thermal lamination process, in contrast to conventional wire-based cochlear electrode arrays. Using a thin-film process of LCP-film-mounted silicon wafer and thermal press lamination, we devise a multi-layered structure with variable layers of LCP films to achieve a sufficient degree of basal rigidity and a flexible tip. A peripheral blind via and self-aligned silicone elastomer molding process can reduce the width of the array. Measuring the insertion and extraction forces in a human scala tympani model, we investigate five human temporal bone insertion trials and record electrically evoked auditory brainstem responses (EABR) acutely in a guinea pig model. The diameters of the finalized electrode arrays are 0.3 mm (tip) and 0.75 mm (base). The insertion force with a displacement of 8 mm from a round window and the maximum extraction force are 2.4 mN and 34.0 mN, respectively. The electrode arrays can be inserted from 360° to 630° without trauma at the basal turn. The EABR data confirm the efficacy of the array. A new design of LCP-based cochlear electrode array for atraumatic implantation is fabricated. Verification indicates that foretells the development of an atraumatic cochlear electrode array and clinical implant.
Collapse
|
43
|
Effect of embedded optical fibres on the mechanical properties of cochlear electrode arrays. Med Eng Phys 2016; 38:155-62. [DOI: 10.1016/j.medengphy.2015.11.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 11/11/2015] [Accepted: 11/24/2015] [Indexed: 11/22/2022]
|
44
|
Highly Flexible Silicone Coated Neural Array for Intracochlear Electrical Stimulation. BIOMED RESEARCH INTERNATIONAL 2015; 2015:109702. [PMID: 26236714 PMCID: PMC4509491 DOI: 10.1155/2015/109702] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2014] [Accepted: 01/22/2015] [Indexed: 11/17/2022]
Abstract
We present an effective method for tailoring the flexibility of a commercial thin-film polymer electrode array for intracochlear electrical stimulation. Using a pneumatically driven dispensing system, an average 232 ± 64 μm (mean ± SD) thickness layer of silicone adhesive coating was applied to stiffen the underside of polyimide multisite arrays. Additional silicone was applied to the tip to protect neural tissue during insertion and along the array to improve surgical handling. Each array supported 20 platinum sites (180 μm dia., 250 μm pitch), spanning nearly 28 mm in length and 400 μm in width. We report an average intracochlear stimulating current threshold of 170 ± 93 μA to evoke an auditory brainstem response in 7 acutely deafened felines. A total of 10 arrays were each inserted through a round window approach into the cochlea's basal turn of eight felines with one delamination occurring upon insertion (preliminary results of the in vivo data presented at the 48th Annual Meeting American Neurotology Society, Orlando, FL, April 2013, and reported in Van Beek-King 2014). Using microcomputed tomography imaging (50 μm resolution), distances ranging from 100 to 565 μm from the cochlea's central modiolus were measured. Our method combines the utility of readily available commercial devices with a straightforward postprocessing step on the order of 24 hours.
Collapse
|
45
|
Le Breton A, Jegoux F, Pilet P, Godey B. Micro-CT scan, electron microscopy and optical microscopy study of insertional traumas of cochlear implants. Surg Radiol Anat 2015; 37:815-23. [DOI: 10.1007/s00276-015-1469-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Accepted: 03/23/2015] [Indexed: 11/29/2022]
|
46
|
Zeng FG, Rebscher SJ, Fu QJ, Chen H, Sun X, Yin L, Ping L, Feng H, Yang S, Gong S, Yang B, Kang HY, Gao N, Chi F. Development and evaluation of the Nurotron 26-electrode cochlear implant system. Hear Res 2014; 322:188-99. [PMID: 25281795 DOI: 10.1016/j.heares.2014.09.013] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 08/18/2014] [Accepted: 09/03/2014] [Indexed: 11/29/2022]
Abstract
Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled <Lasker Award>.
Collapse
Affiliation(s)
- Fan-Gang Zeng
- Center for Hearing Research, University of California, Irvine, CA 92697, USA.
| | - Stephen J Rebscher
- Department of Otolaryngology - Head and Neck Surgery, University of California, San Francisco, CA 94143, USA
| | - Qian-Jie Fu
- Department of Otolaryngology - Head and Neck Surgery, University of California, Los Angeles, CA 90095, USA
| | - Hongbin Chen
- Nurotron Biotechnology Inc., Hangzhou, Zhejiang 310011, China
| | - Xiaoan Sun
- Nurotron Biotechnology Inc., Hangzhou, Zhejiang 310011, China
| | - Li Yin
- Nurotron Biotechnology Inc., Hangzhou, Zhejiang 310011, China
| | - Lichuan Ping
- Nurotron Biotechnology Inc., Hangzhou, Zhejiang 310011, China
| | - Haihong Feng
- Shanghai Acoustics Laboratory, Institute of Acoustics, Chinese Academy of Sciences, Shanghai 200032, China
| | - Shiming Yang
- Department of Otolaryngology - Head and Neck Surgery, Chinese PLA General Hospital, Beijing 100853, China
| | - Shusheng Gong
- Department of Otolaryngology - Head and Neck Surgery, Beijing Tongren Hospital of Capital Medical University, Beijing 100730, China
| | - Beibei Yang
- Department of Otolaryngology - Head and Neck Surgery, The Second Affiliated Hospital of Zhejiang University, Hangzhou 310000, China
| | - Hou-Yong Kang
- Department of Otolaryngology - Head and Neck Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Na Gao
- Department of Otolaryngology - Head and Neck Surgery, The Eye and ENT Hospital of Fudan University, Shanghai 200031, China
| | - Fanglu Chi
- Department of Otolaryngology - Head and Neck Surgery, The Eye and ENT Hospital of Fudan University, Shanghai 200031, China.
| |
Collapse
|
47
|
Kale S, Cervantes VM, Wu MR, Pisano DV, Sheth N, Olson ES. A novel perfusion-based method for cochlear implant electrode insertion. Hear Res 2014; 314:33-41. [PMID: 24882641 DOI: 10.1016/j.heares.2014.05.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2014] [Revised: 05/07/2014] [Accepted: 05/18/2014] [Indexed: 10/25/2022]
Abstract
A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal turn. In the present study we report on the development of a new method to assist CI electrode insertion. The design objectives are (1) an automated and standardized insertion technique across patients with (2) more apical insertion than is possible by the contemporary methods, while (3) minimizing insertion trauma. The method relies on a viscous fluid flow through the cochlea to carry the electrode array with it. A small cochleostomy (∼100-150 um in diameter) is made in scala vestibuli (SV) and the round window (RW) membrane is opened. A flow of diluted Sodium Hyaluronate (also known as Hyaluronic Acid, (HA)) is set up from the RW to the SV opening using a perfusion pump that sets up a unidirectional flow. Once the flow is established an implant is dropped into the ongoing flow. Here we present a proof-of-concept study where we used this technique to insert silicone implants all the way to the cochlear apex in rats and gerbils. In light-microscopic histology, the implantation occurred without cochlear trauma. To further assess the ototoxicity of the HA perfusion, we measured compound action potential (CAP) thresholds following the perfusion of HA, and found that the CAP thresholds were substantially elevated. Thus, at this point the method is promising, and requires further development to become clinically viable.
Collapse
Affiliation(s)
- Sushrut Kale
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA.
| | - Vanessa M Cervantes
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA
| | - Mailing R Wu
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA; Department of Biomedical Engineering, Columbia University, New York, NY 10025, USA
| | - Dominic V Pisano
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA
| | - Nakul Sheth
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA
| | - Elizabeth S Olson
- Department of Otolaryngology-Head & Neck Surgery, Columbia University, New York, NY 10032, USA; Department of Biomedical Engineering, Columbia University, New York, NY 10025, USA
| |
Collapse
|
48
|
Avci E, Nauwelaers T, Lenarz T, Hamacher V, Kral A. Variations in microanatomy of the human cochlea. J Comp Neurol 2014; 522:3245-61. [PMID: 24668424 PMCID: PMC4265794 DOI: 10.1002/cne.23594] [Citation(s) in RCA: 159] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 03/21/2014] [Accepted: 03/21/2014] [Indexed: 11/11/2022]
Abstract
The human cochlea shows considerable interindividual variability in size and morphology. In order to develop atraumatic cochlear implant (CI) electrodes, high-precision details of the variability of human anatomy are required. Sixteen human temporal bones were cut around the cochlea in blocks of approximately 3.5 × 3.5 cm. The bones were scanned by using a Skyscan 1173 micro-computed tomography (μCT) device. Mimics software (Materialise, Leuven, Belgium) was used to segment out the scala tympani (ST) from the μCT images. A three-dimensional surface model of the segmented area was generated for each cochlea. Cross-sectional images were taken and analyzed by custom-designed software in MATLAB. Comparison of different STs showed large variability in cross-sectional diameter (CSD), vertical trajectory, and height of the ST. Relative standard deviations of the CSD were between 9 and 15%. Heights measured at the center of the ST exceeded those in the modiolar and lateral regions of the scala. At the lateral region, the height decreased significantly at the beginning of the second turn. In the vertical trajectory, critical anatomic features were observed, such as dips, vertical jumps, and peaks. Rosenthal's canal (RC) extended to between 560 and 650°. We found a correlation between the length of the RC and that of the ST. The ST was segmented and the internal dimensions measured by using μCT. We observed large dimensional variability between different STs. These differences could have considerable implications for approaches to the design of CI arrays, especially in terms of their ability to preserve residual hearing during insertion of the electrode array. J. Comp. Neurol. 522:3245–3261, 2014. © 2014 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Ersin Avci
- Cluster of Excellence Hearing4all, Institute of AudioNeuroTechnology and Department of Experimental Otology, Ear, Nose, and Throat Clinics, Hannover Medical University, Hannover, 30625, Germany
| | | | | | | | | |
Collapse
|
49
|
|
50
|
Wade SA, Fallon JB, Wise AK, Shepherd RK, James NL, Stoddart PR. Measurement of Forces at the Tip of a Cochlear Implant During Insertion. IEEE Trans Biomed Eng 2014; 61:1177-86. [DOI: 10.1109/tbme.2013.2296566] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|