1
|
Koyama H, Kashio A, Yamasoba T. Prediction of Cochlear Implant Fitting by Machine Learning Techniques. Otol Neurotol 2024; 45:643-650. [PMID: 38769101 DOI: 10.1097/mao.0000000000004205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
OBJECTIVE This study aimed to evaluate the differences in electrically evoked compound action potential (ECAP) thresholds and postoperative mapping current (T) levels between electrode types after cochlear implantation, the correlation between ECAP thresholds and T levels, and the performance of machine learning techniques in predicting postoperative T levels. STUDY DESIGN Retrospective case review. SETTING Tertiary hospital. PATIENTS We reviewed the charts of 124 ears of children with severe-to-profound hearing loss who had undergone cochlear implantation. INTERVENTIONS We compared ECAP thresholds and T levels from different electrodes, calculated correlations between ECAP thresholds and T levels, and created five prediction models of T levels at switch-on and 6 months after surgery. MAIN OUTCOME MEASURES The accuracy of prediction in postoperative mapping current (T) levels. RESULTS The ECAP thresholds of the slim modiolar electrodes were significantly lower than those of the straight electrodes on the apical side. However, there was no significant difference in the neural response telemetry thresholds between the two electrodes on the basal side. Lasso regression achieved the most accurate prediction of T levels at switch-on, and the random forest algorithm achieved the most accurate prediction of T levels 6 months after surgery in this dataset. CONCLUSION Machine learning techniques could be useful for accurately predicting postoperative T levels after cochlear implantation in children.
Collapse
Affiliation(s)
- Hajime Koyama
- Department of Otorhinolaryngology and Head and Neck Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | | | | |
Collapse
|
2
|
Takanen M, Strahl S, Schwarz K. Insights Into Electrophysiological Metrics of Cochlear Health in Cochlear Implant Users Using a Computational Model. J Assoc Res Otolaryngol 2024; 25:63-78. [PMID: 38278970 PMCID: PMC10907331 DOI: 10.1007/s10162-023-00924-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 12/18/2023] [Indexed: 01/28/2024] Open
Abstract
PURPOSE The hearing outcomes of cochlear implant users depend on the functional status of the electrode-neuron interface inside the cochlea. This can be assessed by measuring electrically evoked compound action potentials (eCAPs). Variations in cochlear neural health and survival are reflected in eCAP-based metrics. The difficulty in translating promising results from animal studies into clinical use has raised questions about to what degree eCAP-based metrics are influenced by non-neural factors. Here, we addressed these questions using a computational model. METHODS A 2-D computational model was designed to simulate how electrical signals from the stimulating electrode reach the auditory nerve fibers distributed along the cochlea, evoking action potentials that can be recorded as compound responses at the recording electrodes. Effects of physiologically relevant variations in neural survival and in electrode-neuron and stimulating-recording electrode distances on eCAP amplitude growth functions (AGFs) were investigated. RESULTS In line with existing literature, the predicted eCAP AGF slopes and the inter-phase gap (IPG) effects depended on the neural survival, but only when the IPG effect was calculated as the difference between the slopes of the two AGFs expressed in linear input-output scale. As expected, shallower eCAP AGF slopes were obtained for increased stimulating-recording electrode distance and larger eCAP thresholds for greater electrode-neuron distance. These non-neural factors had also minor interference on the predicted IPG effect. CONCLUSIONS The model predictions demonstrate previously found dependencies of eCAP metrics on neural survival and non-neural aspects. The present findings confirm data from animal studies and provide insights into applying described metrics in clinical practice.
Collapse
Affiliation(s)
- Marko Takanen
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria.
| | - Stefan Strahl
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria
| | - Konrad Schwarz
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria
| |
Collapse
|
3
|
Vink HA, Ramekers D, Foster AC, Versnel H. The efficacy of a TrkB monoclonal antibody agonist in preserving the auditory nerve in deafened guinea pigs. Hear Res 2023; 439:108895. [PMID: 37837701 DOI: 10.1016/j.heares.2023.108895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 08/31/2023] [Accepted: 10/02/2023] [Indexed: 10/16/2023]
Abstract
The auditory nerve typically degenerates following loss of cochlear hair cells or synapses. In the case of hair cell loss neural degeneration hinders restoration of hearing through a cochlear implant, and in the case of synaptopathy suprathreshold hearing is affected, potentially degrading speech perception in noise. It has been established that neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3 (NT-3) can mitigate auditory nerve degeneration. Several potential BDNF mimetics have also been investigated for neurotrophic effects in the cochlea. A recent in vitro study showed favorable effects of M3, a TrkB monoclonal antibody agonist, when compared with BDNF. In the present study we set out to examine the effect of M3 on auditory nerve preservation in vivo. Thirty-one guinea pigs were bilaterally deafened, and unilaterally treated with a single 3-µl dose of 7 mg/ml, 0.7 mg/ml M3 or vehicle-only by means of a small gelatin sponge two weeks later. During the experiment and analyses the experimenters were blinded to the three treatment groups. Four weeks after treatment, we assessed the treatment effect (1) histologically, by quantifying survival of SGCs and their peripheral processes (PPs); and (2) electrophysiologically, with two different paradigms of electrically evoked compound action potential (eCAP) recordings shown to be indicative of neural health: single-pulse stimulation with varying inter-phase gap (IPG), and pulse-train stimulation with varying inter-pulse interval. We observed a consistent and significant preservative effect of M3 on SGC survival in the lower basal turn (approximately 40% more survival than in the untreated contralateral cochlea), but also in the upper middle and lower apical turn of the cochlea. This effect was similar for the two treatment groups. Survival of PPs showed a trend similar to that of the SGCs, but was only significantly higher for the highest dose of M3. The protective effect of M3 on SGCs was not reflected in any of the eCAP measures: no statistically significant differences were observed between groups in IPG effect nor between the M3 treatment groups and the control group using the pulse-train stimulation paradigm. In short, while a clear effect of M3 was observed on SGC survival, this was not clearly translated into functional preservation.
Collapse
Affiliation(s)
- Henk A Vink
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Room G.02.531, P.O. Box 85500, 3508 GA, Utrecht, the Netherlands; UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Dyan Ramekers
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Room G.02.531, P.O. Box 85500, 3508 GA, Utrecht, the Netherlands; UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | | | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Room G.02.531, P.O. Box 85500, 3508 GA, Utrecht, the Netherlands; UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands.
| |
Collapse
|
4
|
Liebscher T, Hornung J, Hoppe U. Electrically evoked compound action potentials in cochlear implant users with preoperative residual hearing. Front Hum Neurosci 2023; 17:1125747. [PMID: 37850038 PMCID: PMC10577430 DOI: 10.3389/fnhum.2023.1125747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 09/08/2023] [Indexed: 10/19/2023] Open
Abstract
Introduction Residual hearing in cochlear implant (CI) candidates requires the functional integrity of the nerve in particular regions of the cochlea. Nerve activity can be elicited as electrically evoked compound action potentials (ECAP) after cochlear implantation. We hypothesize that ECAP thresholds depend on preoperative residual hearing ability. Materials and methods In a retrospective study, we analyzed 84 adult cochlear implant users who had received a Nucleus® CI632 Slim Modiolar Electrode and who preoperatively had had residual hearing. Inclusion criteria were severe to profound hearing loss with preoperative measurable hearing in the ear to receive the implant, postlingual hearing loss, German as native language and correct placement of the electrode, inserted completely into the scala tympani. Electrically evoked compound action potential (ECAP) was recorded intraoperatively. The angular insertion was measured for each electrode contact from postoperative computed tomography to estimate the corresponding spiral ganglion frequency. Pure-tone audiometry and allocated ECAP thresholds were tested to investigate possible correlation. Results The average of hearing thresholds, tested at 0.5, 1, 2, and 4 kHz (4FPTA) was 82 ± 18 (range 47-129) dB HL. The success rate for recording ECAP thresholds was 96.9%. For all comparable pure-tone frequencies (1, 2, 4, and 8 kHz), there was significant correlation between preoperative hearing levels and intraoperative ECAP thresholds (p < 0.001). Higher hearing thresholds are associated with increased ECAP thresholds. Conclusion In CI candidates with adequate residual hearing, intraoperative electrophysiological measurement records lower thresholds. This outcome may be explained by the neural survival density of the peripheral system, with less neural degeneration.
Collapse
Affiliation(s)
- Tim Liebscher
- ENT-Clinic, Department of Audiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | | |
Collapse
|
5
|
Gilbert Z, Mason X, Sebastian R, Tang AM, Martin Del Campo-Vera R, Chen KH, Leonor A, Shao A, Tabarsi E, Chung R, Sundaram S, Kammen A, Cavaleri J, Gogia AS, Heck C, Nune G, Liu CY, Kellis SS, Lee B. A review of neurophysiological effects and efficiency of waveform parameters in deep brain stimulation. Clin Neurophysiol 2023; 152:93-111. [PMID: 37208270 DOI: 10.1016/j.clinph.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 02/09/2023] [Accepted: 04/15/2023] [Indexed: 05/21/2023]
Abstract
Neurostimulation has diverse clinical applications and potential as a treatment for medically refractory movement disorders, epilepsy, and other neurological disorders. However, the parameters used to program electrodes-polarity, pulse width, amplitude, and frequency-and how they are adjusted have remained largely untouched since the 1970 s. This review summarizes the state-of-the-art in Deep Brain Stimulation (DBS) and highlights the need for further research to uncover the physiological mechanisms of neurostimulation. We focus on studies that reveal the potential for clinicians to use waveform parameters to selectively stimulate neural tissue for therapeutic benefit, while avoiding activating tissue associated with adverse effects. DBS uses cathodic monophasic rectangular pulses with passive recharging in clinical practice to treat neurological conditions such as Parkinson's Disease. However, research has shown that stimulation efficiency can be improved, and side effects reduced, through modulating parameters and adding novel waveform properties. These developments can prolong implantable pulse generator lifespan, reducing costs and surgery-associated risks. Waveform parameters can stimulate neurons based on axon orientation and intrinsic structural properties, providing clinicians with more precise targeting of neural pathways. These findings could expand the spectrum of diseases treatable with neuromodulation and improve patient outcomes.
Collapse
Affiliation(s)
- Zachary Gilbert
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States.
| | - Xenos Mason
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Rinu Sebastian
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Austin M Tang
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Roberto Martin Del Campo-Vera
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Kuang-Hsuan Chen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Andrea Leonor
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Arthur Shao
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Emiliano Tabarsi
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Ryan Chung
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Shivani Sundaram
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Alexandra Kammen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Jonathan Cavaleri
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Angad S Gogia
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Christi Heck
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - George Nune
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Charles Y Liu
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Spencer S Kellis
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Brian Lee
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| |
Collapse
|
6
|
Hughes ML. Electrically evoked compound action potential polarity sensitivity, refractory-recovery, and behavioral multi-pulse integration as potential indices of neural health in cochlear-implant recipients. Hear Res 2023; 433:108764. [PMID: 37062161 PMCID: PMC10322179 DOI: 10.1016/j.heares.2023.108764] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 03/26/2023] [Accepted: 04/05/2023] [Indexed: 04/18/2023]
Affiliation(s)
- Michelle L Hughes
- University of Nebraska-Lincoln, Dept. of Special Education and Communication Disorders, 276 Barkley Memorial Center, 4072 East Campus Loop, Lincoln, NE, 68583, USA.
| |
Collapse
|
7
|
Zamaninezhad L, Mert B, Benav H, Tillein J, Garnham C, Baumann U. Factors influencing the relationship between cochlear health measures and speech recognition in cochlear implant users. Front Integr Neurosci 2023; 17:1125712. [PMID: 37251736 PMCID: PMC10213548 DOI: 10.3389/fnint.2023.1125712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 03/27/2023] [Indexed: 05/31/2023] Open
Abstract
Background One factor which influences the speech intelligibility of cochlear implant (CI) users is the number and the extent of the functionality of spiral ganglion neurons (SGNs), referred to as "cochlear health." To explain the interindividual variability in speech perception of CI users, a clinically applicable estimate of cochlear health could be insightful. The change in the slope of the electrically evoked compound action potentials (eCAP), amplitude growth function (AGF) as a response to increased interphase gap (IPG) (IPGEslope) has been introduced as a potential measure of cochlear health. Although this measure has been widely used in research, its relationship to other parameters requires further investigation. Methods This study investigated the relationship between IPGEslope, demographics and speech intelligibility by (1) considering the relative importance of each frequency band to speech perception, and (2) investigating the effect of the stimulus polarity of the stimulating pulse. The eCAPs were measured in three different conditions: (1) Forward masking with anodic-leading (FMA) pulse, (2) Forward masking with cathodic-leading (FMC) pulse, and (3) with alternating polarity (AP). This allowed the investigation of the effect of polarity on the diagnosis of cochlear health. For an accurate investigation of the correlation between IPGEslope and speech intelligibility, a weighting function was applied to the measured IPGEslopes on each electrode in the array to consider the relative importance of each frequency band for speech perception. A weighted Pearson correlation analysis was also applied to compensate for the effect of missing data by giving higher weights to the ears with more successful IPGEslope measurements. Results A significant correlation was observed between IPGEslope and speech perception in both quiet and noise for between-subject data especially when the relative importance of frequency bands was considered. A strong and significant correlation was also observed between IPGEslope and age when stimulation was performed with cathodic-leading pulses but not for the anodic-leading pulse condition. Conclusion Based on the outcome of this study it can be concluded that IPGEslope has potential as a relevant clinical measure indicative of cochlear health and its relationship to speech intelligibility. The polarity of the stimulating pulse could influence the diagnostic potential of IPGEslope.
Collapse
Affiliation(s)
| | - Berkutay Mert
- ENT/Audiological Acoustics, University Hospital, Goethe University Frankfurt, Frankfurt, Germany
| | | | | | | | - Uwe Baumann
- ENT/Audiological Acoustics, University Hospital, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
8
|
Alvarez F, Kipping D, Nogueira W. A computational model to simulate spectral modulation and speech perception experiments of cochlear implant users. Front Neuroinform 2023; 17:934472. [PMID: 37006637 PMCID: PMC10061543 DOI: 10.3389/fninf.2023.934472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 02/15/2023] [Indexed: 03/11/2023] Open
Abstract
Speech understanding in cochlear implant (CI) users presents large intersubject variability that may be related to different aspects of the peripheral auditory system, such as the electrode–nerve interface and neural health conditions. This variability makes it more challenging to proof differences in performance between different CI sound coding strategies in regular clinical studies, nevertheless, computational models can be helpful to assess the speech performance of CI users in an environment where all these physiological aspects can be controlled. In this study, differences in performance between three variants of the HiRes Fidelity 120 (F120) sound coding strategy are studied with a computational model. The computational model consists of (i) a processing stage with the sound coding strategy, (ii) a three-dimensional electrode-nerve interface that accounts for auditory nerve fiber (ANF) degeneration, (iii) a population of phenomenological ANF models, and (iv) a feature extractor algorithm to obtain the internal representation (IR) of the neural activity. As the back-end, the simulation framework for auditory discrimination experiments (FADE) was chosen. Two experiments relevant to speech understanding were performed: one related to spectral modulation threshold (SMT), and the other one related to speech reception threshold (SRT). These experiments included three different neural health conditions (healthy ANFs, and moderate and severe ANF degeneration). The F120 was configured to use sequential stimulation (F120-S), and simultaneous stimulation with two (F120-P) and three (F120-T) simultaneously active channels. Simultaneous stimulation causes electric interaction that smears the spectrotemporal information transmitted to the ANFs, and it has been hypothesized to lead to even worse information transmission in poor neural health conditions. In general, worse neural health conditions led to worse predicted performance; nevertheless, the detriment was small compared to clinical data. Results in SRT experiments indicated that performance with simultaneous stimulation, especially F120-T, were more affected by neural degeneration than with sequential stimulation. Results in SMT experiments showed no significant difference in performance. Although the proposed model in its current state is able to perform SMT and SRT experiments, it is not reliable to predict real CI users' performance yet. Nevertheless, improvements related to the ANF model, feature extraction, and predictor algorithm are discussed.
Collapse
Affiliation(s)
- Franklin Alvarez
- Medizinische Hochschule Hannover, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Daniel Kipping
- Medizinische Hochschule Hannover, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Waldo Nogueira
- Medizinische Hochschule Hannover, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
- *Correspondence: Waldo Nogueira
| |
Collapse
|
9
|
Lambriks L, van Hoof M, Debruyne J, Janssen M, Hof J, Hellingman K, Devocht E, George E. Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and behavioral stimulation levels. Front Neurol 2023; 14:1093265. [PMID: 36846130 PMCID: PMC9948626 DOI: 10.3389/fneur.2023.1093265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Estimating differences in neural health across different sites within the individual cochlea potentially enables clinical applications for subjects with a cochlear implant. The electrically evoked compound action potential (ECAP) is a measure of neural excitability that possibly provides an indication of a neural condition. There are many factors, however, that affect this measure and increase the uncertainty of its interpretation. To better characterize the ECAP response, its relationship with electrode positioning, impedances, and behavioral stimulation levels was explored. Methods A total of 14 adult subjects implanted with an Advanced Bionics cochlear electrode array were prospectively followed up from surgery to 6 months postoperative. Insertion depth, distance to the modiolus, and distance to the medial wall were assessed for each electrode by postoperative CT analysis. ECAPs were measured intraoperatively and at three visits postoperatively on all 16 electrodes using the NRI feature of clinical programming software and characterized using multiple parameters. Impedances and behavioral stimulation levels were measured at every fitting session. Results Patterns in ECAPs and impedances were consistent over time, but high variability existed among subjects and between different positions in the cochlea. Electrodes located closer to the apex of the cochlea and closer to the modiolus generally showed higher neural excitation and higher impedances. Maximum loudness comfort levels were correlated strongly with the level of current needed to elicit a response of 100 μV ECAP. Conclusion Multiple factors contribute to the ECAP response in subjects with a cochlear implant. Further research might address whether the ECAP parameters used in this study will benefit clinical electrode fitting or the assessment of auditory neuron integrity.
Collapse
Affiliation(s)
- Lars Lambriks
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,*Correspondence: Lars Lambriks ✉
| | - Marc van Hoof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Joke Debruyne
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Miranda Janssen
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | - Janny Hof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Katja Hellingman
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Elke Devocht
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Erwin George
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
10
|
Wu SS, Sawaf T, Vovos R, Goldberg D, Hadford S, Anne S. Intraoperative Neural Response Telemetry and Auditory Outcomes in Pediatric Cochlear Implantation. Otolaryngol Head Neck Surg 2023; 168:1178-1184. [PMID: 36939531 DOI: 10.1002/ohn.176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 09/16/2022] [Accepted: 09/28/2022] [Indexed: 02/10/2023]
Abstract
OBJECTIVE To evaluate the relationship between intraoperative neural response telemetry (NRT) and postoperative auditory testing outcomes in children. STUDY DESIGN Retrospective study. SETTING Tertiary-care academic center. METHODS Children who underwent cochlear implantation using the Cochlear Corporation device between 2010 and 2019 were included. Associations of average NRT and the slope of amplitude with postoperative auditory outcomes including functional auditory measure Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), and speech perception testing (consonant-nucleus-consonant [CNC], Pediatric AzBio [BABY BIO], Hearing In Noise Test [HINT], and Northwestern University Children's Perception of Speech [NU-CHIPS]), measured between 6 and 57 months after implantation, were assessed using Spearman's rank correlation (ρ). RESULTS Thirty-eight patients (19 female, 19 male) and 54 ears were included. The median age of implantation was 20.6 months (range 9.6 months to 10.6 years). Eight (21%) children had neurologic disorders such as stroke, epilepsy, cerebral palsy, and other causes. Thirteen (34%) children had connexin mutations. Average NRT was not significantly correlated with postoperative auditory outcomes (IT-MAIS [ρ = -0.08, p = .74], CNC [ρ = 0.19, p = .32], BABY BIO [ρ = 0.21, p = .29], HINT [ρ = 0.05, p = .83]) and NU-CHIPS (ρ = 0.21, p = .28). The average slopes of amplitude and comfort level were not strongly correlated with any auditory outcomes (p > .05). CONCLUSIONS Intraoperative NRT was not correlated with any postoperative functional auditory outcomes. Patient counseling should include discussions that a subpar intraoperative cochlear response does not preclude favorable speech and auditory outcomes.
Collapse
Affiliation(s)
- Shannon S Wu
- Department of Otolaryngology, Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio, USA
| | - Tuleen Sawaf
- Department of Otolaryngology, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
| | - Rachel Vovos
- Head and Neck Institute, Department of Otolaryngology, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Donald Goldberg
- Head and Neck Institute, Department of Otolaryngology, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Stephen Hadford
- Head and Neck Institute, Department of Otolaryngology, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Samantha Anne
- Head and Neck Institute, Department of Otolaryngology, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| |
Collapse
|
11
|
Schvartz-Leyzac KC, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Cochlear Health and Cochlear-implant Function. J Assoc Res Otolaryngol 2023; 24:5-29. [PMID: 36600147 PMCID: PMC9971430 DOI: 10.1007/s10162-022-00882-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 11/24/2022] [Indexed: 01/06/2023] Open
Abstract
The cochlear implant (CI) is widely considered to be one of the most innovative and successful neuroprosthetic treatments developed to date. Although outcomes vary, CIs are able to effectively improve hearing in nearly all recipients and can substantially improve speech understanding and quality of life for patients with significant hearing loss. A wealth of research has focused on underlying factors that contribute to success with a CI, and recent evidence suggests that the overall health of the cochlea could potentially play a larger role than previously recognized. This article defines and reviews attributes of cochlear health and describes procedures to evaluate cochlear health in humans and animal models in order to examine the effects of cochlear health on performance with a CI. Lastly, we describe how future biologic approaches can be used to preserve and/or enhance cochlear health in order to maximize performance for individual CI recipients.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Ave, Charleston, SC, 29425, USA
| | - Deborah J Colesa
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Donald L Swiderski
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Yehoash Raphael
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Bryan E Pfingst
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
| |
Collapse
|
12
|
Garcia C, Deeks JM, Goehring T, Borsetto D, Bance M, Carlyon RP. SpeedCAP: An Efficient Method for Estimating Neural Activation Patterns Using Electrically Evoked Compound Action-Potentials in Cochlear Implant Users. Ear Hear 2022; 44:627-640. [PMID: 36477611 PMCID: PMC10097494 DOI: 10.1097/aud.0000000000001305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVES Electrically evoked compound action-potentials (ECAPs) can be recorded using the electrodes in a cochlear implant (CI) and represent the synchronous responses of the electrically stimulated auditory nerve. ECAPs can be obtained using a forward-masking method that measures the neural response to a probe and masker electrode separately and in combination. The panoramic ECAP (PECAP) analyses measured ECAPs obtained using multiple combinations of masker and probe electrodes and uses a nonlinear optimization algorithm to estimate current spread from each electrode and neural health along the cochlea. However, the measurement of ECAPs from multiple combinations of electrodes is too time consuming for use in clinics. Here, we propose and evaluate SpeedCAP, a speedy method for obtaining the PECAP measurements that minimizes recording time by exploiting redundancies between multiple ECAP measures. DESIGN In the first study, 11 users of Cochlear Ltd. CIs took part. ECAPs were recorded using the forward-masking artifact-cancelation technique at the most comfortable loudness level (MCL) for every combination of masker and probe electrodes for all active electrodes in the users' MAPs, as per the standard PECAP recording paradigm. The same current levels and recording parameters were then used to collect ECAPs in the same users with the SpeedCAP method. The ECAP amplitudes were then compared between the two conditions, as were the corresponding estimates of neural health and current spread calculated using the PECAP method previously described by Garcia et al. The second study measured SpeedCAP intraoperatively in 8 CI patients and with all maskers and probes presented at the same current level to assess feasibility. ECAPs for the subset of conditions where the masker and probe were presented on the same electrode were compared with those obtained using the slower approach leveraged by the standard clinical software. RESULTS Data collection time was reduced from ≈45 to ≈8 minutes. There were no significant differences between normalized root mean squared error (RMSE) repeatability metrics for post-operative PECAP and SpeedCAP data, nor for the RMSEs calculated between PECAP and SpeedCAP data. The comparison achieved 80% power to detect effect sizes down to 8.2% RMSE. When between-participant differences were removed, both the neural-health (r = 0.73) and current-spread (r = 0.65) estimates were significantly correlated (p < 0.0001, df = 218) between SpeedCAP and PECAP conditions across all electrodes, and showed RMSE errors of 12.7 ± 4.7% and 16.8 ± 8.8%, respectively (with the ± margins representing 95% confidence intervals). Valid ECAPs were obtained in all patients in the second study, demonstrating intraoperative feasibility of SpeedCAP. No significant differences in RMSEs were detectable between post- and intra-operative ECAP measurements, with the comparison achieving 80% power to detect effect sizes down to 13.3% RMSE. CONCLUSIONS The improved efficiency of SpeedCAP provides time savings facilitating multi-electrode ECAP recordings in routine clinical practice. SpeedCAP data collection is sufficiently quick to record intraoperatively, and adds no more than 8.2% error to the ECAP amplitudes. Such measurements could thereafter be submitted to models such as PECAP to provide patient-specific patterns of neural activation to inform programming of clinical MAPs and identify causes of poor performance at the electrode-nerve interface of CI users. The speed and accuracy of these measurements also opens up a wide range of additional research questions to be addressed.
Collapse
Affiliation(s)
- Charlotte Garcia
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom
| | - John M Deeks
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom
| | - Tobias Goehring
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom
| | - Daniele Borsetto
- Cambridge Hearing Group, Cambridge Universities Hospitals Foundation Trust, University of Cambridge, Cambridge, United Kingdom
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge Universities Hospitals Foundation Trust, University of Cambridge, Cambridge, United Kingdom
| | - Robert P Carlyon
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
13
|
Changes in the Electrically Evoked Compound Action Potential over time After Implantation and Subsequent Deafening in Guinea Pigs. J Assoc Res Otolaryngol 2022; 23:721-738. [PMID: 35948695 PMCID: PMC9789241 DOI: 10.1007/s10162-022-00864-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 07/12/2022] [Indexed: 01/06/2023] Open
Abstract
The electrically evoked compound action potential (eCAP) is a direct measure of the responsiveness of the auditory nerve to electrical stimulation from a cochlear implant (CI). CIs offer a unique opportunity to study the auditory nerve's electrophysiological behavior in individual human subjects over time. In order to understand exactly how the eCAP relates to the condition of the auditory nerve, it is crucial to compare changes in the eCAP over time in a controlled model of deafness-induced auditory nerve degeneration. In the present study, 10 normal-hearing young adult guinea pigs were implanted and deafened 4 weeks later, so that the effect of deafening could be monitored within-subject over time. Following implantation, but before deafening, most examined eCAP characteristics significantly changed, suggesting increasing excitation efficacy (e.g., higher maximum amplitude, lower threshold, shorter latency). Conversely, inter-phase gap (IPG) effects on these measures - within-subject difference measures that have been shown to correlate well with auditory nerve survival - did not vary for most eCAP characteristics. After deafening, we observed an initial increase in excitability (steeper slope of the eCAP amplitude growth function (AGF), lower threshold, shorter latency and peak width) which typically returned to normal-hearing levels within a week, after which a slower process, probably reflecting spiral ganglion cell loss, took place over the remaining 6 weeks (e.g., decrease in maximum amplitude, AGF slope, peak area, and IPG effect for AGF slope; increase in IPG effect for latency). Our results suggest that gradual changes in peak width and latency reflect the rate of neural degeneration, while peak area, maximum amplitude, and AGF slope reflect neural population size, which may be valuable for clinical diagnostics.
Collapse
|
14
|
Arslan NO, Luo X. Assessing the Relationship Between Pitch Perception and Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2022; 23:875-887. [PMID: 36329369 PMCID: PMC9789247 DOI: 10.1007/s10162-022-00876-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Various neural health estimates have been shown to indicate the density of spiral ganglion neurons in animal and modeling studies of cochlear implants (CIs). However, when applied to human CI users, these neural health estimates based on psychophysical and electrophysiological measures are not consistently correlated with each other or with the speech recognition performance. This study investigated whether the neural health estimates have stronger correlations with the temporal and place pitch sensitivity than with the speech recognition performance. On five electrodes in 12 tested ears of eight adult CI users, polarity effect (PE), multipulse integration (MPI), and interphase gap (IPG) effect on the amplitude growth function (AGF) of electrically evoked compound action potential (ECAP) were measured to estimate neural health, while thresholds of amplitude modulation frequency ranking (AMFR) and virtual channel ranking (VCR) were measured to indicate temporal and place pitch sensitivity. AzBio sentence recognition in noise was measured using the clinical CI processor for each ear. The results showed significantly poorer AMFR and VCR thresholds on the basal electrodes than on the apical and middle electrodes. Across ears and electrodes, only the IPG offset effect on ECAP AGF had a nearly significant negative correlation with the VCR threshold after removing the outliers. No significant across-ear correlations were found between the mean neural health estimates, mean pitch-ranking thresholds, and AzBio sentence recognition score. This study suggests that the central axon demyelination reflected by the IPG offset effect may be important for the place pitch sensitivity of CI users and that the IPG offset effect may be used to predict the perceptual resolution of virtual channels for CI programming.
Collapse
Affiliation(s)
- Niyazi O. Arslan
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| | - Xin Luo
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| |
Collapse
|
15
|
Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models. Hear Res 2022; 426:108643. [PMID: 36343534 PMCID: PMC9986845 DOI: 10.1016/j.heares.2022.108643] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/29/2022] [Accepted: 10/20/2022] [Indexed: 11/04/2022]
Abstract
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural structures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomical/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is generally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from animal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.
Collapse
|
16
|
Mushtaq F, Soulby A, Boyle P, Nunn T, Hartley DEH. Self-assessment of cochlear health by cochlear implant recipients. Front Neurol 2022; 13:1042408. [DOI: 10.3389/fneur.2022.1042408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 10/25/2022] [Indexed: 11/18/2022] Open
Abstract
Recent technological advances in cochlear implant (CI) telemetry have enabled, for the first time, CI users to perform cochlear health (CH) measurements through self-assessment for prolonged periods of time. This is important to better understand the influence of CH on CI outcomes, and to assess the safety and efficacy of future novel treatments for deafness that will be administered as adjunctive therapies to cochlear implantation. We evaluated the feasibility of using a CI to assess CH and examined patterns of electrode impedances, electrically-evoked compound action potentials (eCAPs) and electrocochleography (ECochGs), over time, in a group of adult CI recipients. Fifteen subjects were trained to use the Active Insertion Monitoring tablet by Advanced Bionics, at home for 12 weeks to independently record impedances twice daily, eCAPs once weekly and ECochGs daily in the first week, and weekly thereafter. Participants also completed behavioral hearing and speech assessments. Group level measurement compliance was 98.9% for impedances, 100% for eCAPs and 99.6% for ECochGs. Electrode impedances remained stable over time, with only minimal variation observed. Morning impedances were significantly higher than evening measurements, and impedances increased toward the base of the cochlea. eCAP thresholds were also highly repeatable, with all subjects showing 100% measurement consistency at, at least one electrode. Just over half of all subjects showed consistently absent thresholds at one or more electrodes, potentially suggesting the existence of cochlear dead regions. All subjects met UK NICE guidelines for cochlear implantation, so were expected to have little residual hearing. ECochG thresholds were, unsurprisingly, highly erratic and did not correlate with audiometric thresholds, though lower ECochG thresholds showed more repeatability over time than higher thresholds. We conclude that it is feasible for CI users to independently record CH measurements using their CI, and electrode impedances and eCAPs are promising measurements for objectively assessing CH.
Collapse
|
17
|
Vink HA, Ramekers D, Thomeer HGXM, Versnel H. Combined brain-derived neurotrophic factor and neurotrophin-3 treatment is preferred over either one separately in the preservation of the auditory nerve in deafened guinea pigs. Front Mol Neurosci 2022; 15:935111. [PMID: 36226314 PMCID: PMC9549372 DOI: 10.3389/fnmol.2022.935111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 08/30/2022] [Indexed: 11/13/2022] Open
Abstract
Severe hearing loss or deafness is often caused by cochlear hair cell loss and can be mitigated by a cochlear implant (CI). CIs target the auditory nerve, consisting of spiral ganglion cells (SGCs), which degenerate gradually, following hair cell loss. In animal models, it has been established that treatment with the neurotrophins brain-derived neurotrophic factor (BDNF) and neurotrophin-3 (NT-3) reduce SGC degeneration. In this study, we aimed to investigate whether treatment with both BDNF and NT-3 (Cocktail) is superior to treatment with each neurotrophin separately regarding cell preservation and neural responsiveness to electrical stimulation. To this end, deafened guinea pigs received neurotrophic treatment in their right ear via a gelatin sponge on the perforated round window membrane, followed by cochlear implantation 4 weeks later in the same ear for electrophysiological recordings to various stimulation paradigms. Normal-hearing and deafened untreated guinea pigs were included as positive and negative controls, respectively. Substantial SGC loss occurred in all deafened animals. Each of the neurotrophic treatments led to enhanced SGC survival mainly in the basal turn of the cochlea, gradually decreasing toward the apex. The Cocktail treatment resulted in the highest SGC survival in the treated ear, followed by BDNF, with the least protection of SGCs following NT-3 treatment. Survival of the SGC’s peripheral processes (PPs) followed the same trend in response to the treatment. However, survival of SGCs and PPs in the contralateral untreated ears was also highest in the Cocktail group. Consequently, analysis of the ratio between the treated and untreated ears showed that the BDNF group, which showed low SGC survival in the untreated ear, had the highest relative SGC survival of the three neurotrophin-treated groups. Neurotrophic treatment had positive effects in part of the electrically evoked compound action-potential recording paradigms. These effects were only observed for the BDNF or Cocktail treatment. We conclude that treatment with either BDNF or a cocktail of BDNF and NT-3 is preferred to NT-3 alone. Furthermore, since the Cocktail treatment resulted in better electrophysiological responsiveness and overall higher SGC survival than BDNF alone, we are inclined to recommend the Cocktail treatment rather than BDNF alone.
Collapse
Affiliation(s)
- Henk A. Vink
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| | - Dyan Ramekers
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- *Correspondence: Dyan Ramekers,
| | - Hans G. X. M. Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| |
Collapse
|
18
|
Di Berardino F, Cavicchiolo S, Del Carmen Fuentes M, Kontides A, Lauss K, Zanetti D. Maximum acceptable level for the determination of ECAP and ESRT in a paediatric population. Cochlear Implants Int 2022; 23:214-224. [PMID: 35380097 DOI: 10.1080/14670100.2022.2054097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVES Two of the most used objective measures are electrically evoked action potentials (ECAPs) and electrically evoked stapedius reflex thresholds (ESRTs). Although stimuli used for these measures differ considerably, both measures are influenced by subjective loudness percept. We focus on the subjective maximum acceptable loudness (MAL) to investigate if loudness sensitivity varied along the electrode array during ECAP recordings. In addition, we explored how the MAL reached during an ECAP recording related to the postoperative ESRT. METHODS Uni- and bilaterally implanted young CI users (n = 15, average age = 9 y, age range 3-18 y) underwent ECAP and ESR recordings using the clinical software MAESTRO (MED-EL, Innsbruck, Austria) and a commercially available immittance instrument (PATH MEDICAL GmbH, Germering, Germany). RESULTS Loudness tolerance during ECAP recordings was lowest at the two apical-most electrode contacts (number 1 and 2). There was a moderate correlation between the MAL achieved during ECAP recordings and ESR maximum stimulation amplitudes. (r: 0.44344). CONCLUSIONS ECAP recordings should commence at basal or medial contacts to increase the users' comfort and loudness tolerance, especially in young CI users. A higher maximum stimulation appears to increase the chance of the automatic determination of ECAP thresholds for all electrode contacts.
Collapse
Affiliation(s)
- Federica Di Berardino
- Audiology Unit, Dept of Clinical Sciences and Community Health, State University of Milano and Dept. of Specialistic Surgical Sciences, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milano, Italy
| | - Sara Cavicchiolo
- Audiology Unit, Dept of Clinical Sciences and Community Health, State University of Milano and Dept. of Specialistic Surgical Sciences, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milano, Italy
| | | | | | | | - Diego Zanetti
- Audiology Unit, Dept of Clinical Sciences and Community Health, State University of Milano and Dept. of Specialistic Surgical Sciences, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milano, Italy
| |
Collapse
|
19
|
Wu CN, Yang CH, Huang PC, Huang YW, Hwang CF. Clinical significance of the neural response telemetric thresholds in Mandarin-speaking cochlear implant patients. J Chin Med Assoc 2022; 85:478-483. [PMID: 35286292 DOI: 10.1097/jcma.0000000000000707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND It is unclear whether neural response telemetric (NRT) thresholds are related to lexical tonal language performance after cochlear implants (CIs). We explored the factors associated with changes in NRT thresholds and postoperative performance of CI patients. METHODS Patients receiving nucleus 24 CIs in our hospital from November 2010 were enrolled. We analyzed medical records and NRT thresholds. Mandarin speech and tone identification were measured in CI patients for at least 1 year postoperatively. RESULTS Seventy-two patients with an average age of 16.1 years received CIs. The postoperative NRT threshold was lower than the intraoperative threshold. The NRT threshold was higher in the early- than the late-activation group (mapping within 21 vs >21 days postoperatively, respectively). Lower intraoperative NRT thresholds and curved electrodes were significantly associated with lower postoperative NRT thresholds. In multiple linear regression analysis, only postoperative NRT thresholds significantly affected speech and tone perception, including word recognition scores, tone perception, and comprehension of easy and difficult sentences (all p < 0.05). Other clinical parameters, including age, gender, implant type, and activation timing, were not significantly associated with clinical tone or speech outcomes. CONCLUSION Curved electrode arrays were associated with lower postoperative NRT thresholds. A lower postoperative NRT threshold might predict better performance of Mandarin-speaking CI patients. Future studies should evaluate factors that affect both postoperative NRT thresholds and lexical tonal language performance.
Collapse
Affiliation(s)
- Ching-Nung Wu
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| | - Chao-Hui Yang
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| | - Ping-Che Huang
- Department of Speech Language Pathology and Audiology, Chung Shan Medical University, Taichung, Taiwan, ROC
| | - Yi-Wen Huang
- Department of Medicine, Shan Medical University, Taichung, Taiwan, ROC
| | - Chung-Feng Hwang
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| |
Collapse
|
20
|
Paknahad J, Humayun M, Lazzi G. Selective Activation of Retinal Ganglion Cell Subtypes Through Targeted Electrical Stimulation Parameters. IEEE Trans Neural Syst Rehabil Eng 2022; 30:350-359. [PMID: 35130164 PMCID: PMC8904155 DOI: 10.1109/tnsre.2022.3149967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To restore vision to the low vision, epiretinal implants have been developed to electrically stimulate the healthy retinal ganglion cells (RGCs) in the degenerate retina. Given the diversity of retinal ganglion cells as well as the difference in their visual function, selective activation of RGCs subtypes can significantly improve the quality of the restored vision. Our recent results demonstrated that with the proper modulation of the current amplitude, small D1-bistratified cells with the contribution to blue/yellow color opponent pathway can be selectively activated at high frequency (200 Hz). The computational results correlated with the clinical findings revealing the blue sensation of 5/7 subjects with epiretinal implants at high frequency. Here we further explored the impacts of alterations in pulse duration and interphase gap on the response of RGCs at high frequency. We used the developed RGCs, A2-monostratified and D1-bistratified, and examined their response to a range of pulse durations (0.1−1.2 ms) and interphase gaps (0−1 ms). We found that the use of short pulse durations with no interphase gap at high frequency increases the differential response of RGCs, offering better opportunities for selective activation of D1 cells. The presence of the interphase gap has shown to reduce the overall differential response of RGCs. We also explored how the low density of calcium channels enhances the responsiveness of RGCs at high frequency.
Collapse
|
21
|
Garadat SN, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Estimating health of the implanted cochlea using psychophysical strength-duration functions and electrode configuration. Hear Res 2022; 414:108404. [PMID: 34883366 PMCID: PMC8761176 DOI: 10.1016/j.heares.2021.108404] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 11/17/2021] [Accepted: 11/25/2021] [Indexed: 02/03/2023]
Abstract
It is generally believed that the efficacy of cochlear implants is partly dependent on the condition of the stimulated neural population. Cochlear pathology is likely to affect the manner in which neurons respond to electrical stimulation, potentially resulting in differences in perception of electrical stimuli across cochlear implant recipients and across the electrode array in individual cochlear implant users. Several psychophysical and electrophysiological measures have been shown to predict cochlear health in animals and were used to assess conditions near individual stimulation sites in humans. In this study, we examined the relationship between psychophysical strength-duration functions and spiral ganglion neuron density in two groups of guinea pigs with cochlear implants who had minimally-overlapping cochlear health profiles. One group was implanted in a hearing ear (N = 10) and the other group was deafened by cochlear perfusion of neomycin, inoculated with an adeno-associated viral vector with an Ntf3-gene insert (AAV.Ntf3) and implanted (N = 14). Psychophysically measured strength-duration functions for both monopolar and tripolar electrode configurations were then compared for the two treatment groups. Results were also compared to their histological outcomes. Overall, there were considerable differences between the two treatment groups in terms of their psychophysical performance as well as the relation between their functional performance and histological data. Animals in the neomycin-deafened, neurotrophin-treated, and implanted group (NNI) exhibited steeper strength-duration function slopes; slopes were positively correlated with SGN density (steeper slopes in animals that had higher SGN densities). In comparison, the implanted hearing (IH) group had shallower slopes and there was no relation between slopes and spiral ganglion density. Across all animals, slopes were negatively correlated with ensemble spontaneous activity levels (shallower slopes with higher ensemble spontaneous activity levels). We hypothesize that differences in strength-duration function slopes between the two treatment groups were related to the condition of the inner hair cells, which generate spontaneous activity that could affect the across-fiber synchrony and/or the size of the population of neural elements responding to electrical stimulation. In addition, it is likely that spiral ganglion neuron peripheral processes were present in the IH group, which could affect membrane properties of the stimulated neurons. Results suggest that the two treatment groups exhibited distinct patterns of variation in conditions near the stimulating electrodes that altered detection thresholds. Overall, the results of this study suggest a complex relationship between psychophysical detection thresholds for cochlear implant stimulation and nerve survival in the implanted cochlea. This relationship seems to depend on the characteristics of the electrical stimulus, the electrode configuration, and other biological features of the implanted cochlea such as the condition of the inner hair cells and the peripheral processes.
Collapse
Affiliation(s)
- Soha N. Garadat
- Department of Hearing and Speech Sciences, The University of Jordan, Amman, 11942, Jordan,Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Deborah J. Colesa
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Donald L. Swiderski
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Yehoash Raphael
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Bryan E. Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| |
Collapse
|
22
|
Yuan Y, Skidmore J, He S. Interpreting the interphase gap effect on the electrically evoked compound action potential. JASA EXPRESS LETTERS 2022; 2:027201. [PMID: 35156092 PMCID: PMC8820158 DOI: 10.1121/10.0009383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 01/06/2022] [Indexed: 06/14/2023]
Abstract
This study demonstrated the effects of using different quantification methods and parameter scales on the sensitivity of the electrically evoked compound action potential (eCAP) to changes in the interphase gap (IPG). The IPG effect measured in two groups of cochlear implant (CI) users with different cochlear nerve (CN) health on seven eCAP measures was quantified using an absolute and a proportional difference method. The IPG effect provides an indicator for the functional status of the CN in human CI users. Specifying how the IPG effect is quantified is critical for accurate result interpretation.
Collapse
Affiliation(s)
- Yi Yuan
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio 43212, USA
| | - Jeffrey Skidmore
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio 43212, USA
| | | |
Collapse
|
23
|
Hughes ML. Characterizing Polarity Sensitivity in Cochlear Implant Recipients: Demographic Effects and Potential Implications for Estimating Neural Health. J Assoc Res Otolaryngol 2022; 23:301-318. [PMID: 34988867 DOI: 10.1007/s10162-021-00824-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 11/17/2021] [Indexed: 11/29/2022] Open
Abstract
Stimulus polarity can affect both physiological and perceptual measures in cochlear-implant recipients. Large differences between polarities for various outcome measures (e.g., eCAP threshold, amplitude, or slope) theoretically reflect poorer neural health, whereas smaller differences reflect better neural health. Therefore, we expect large polarity effects to be correlated with other measures shown to contribute to poor neural health, such as advanced age or prolonged deafness. Our earlier studies using the electrically evoked compound action potential (eCAP) demonstrated differences in polarity effects between users of Cochlear and Advanced Bionics devices when device-specific clinical pulse designs were used. Since the stimuli differed slightly between devices, the first goal of this study was to determine whether small, clinically relevant differences in pulse phase duration (PD) have a significant impact on eCAP polarity effects to potentially explain the device differences observed previously. Polarity effects were quantified as the difference in eCAP thresholds, mean normalized amplitudes, and slope of the amplitude growth function obtained for anodic-first versus cathodic-first biphasic pulses. The results showed that small variations in PD did not explain the observed differences in eCAP polarity effects between devices. Therefore, eCAP polarity sensitivity measures are relatively robust to small differences in pulse parameters. However, it remains unclear what underlies the observed manufacturer differences, which may limit the utility of eCAP polarity sensitivity measures. The second goal was to characterize polarity sensitivity in a large group of CI recipients (65 ears) to relate polarity sensitivity to age and duration of deafness as a proxy for neural health. The same pulse parameters were used for both device groups. The only significant predictors of eCAP polarity effects were age for threshold and amplitude polarity effects for Cochlear recipients and age and duration of deafness for slope for AB recipients. However, three of these four correlations were in the opposite direction of what was expected. These results suggest that eCAP polarity sensitivity measures likely reflect different mechanisms than the effects that age and duration of deafness induce on the peripheral auditory system.
Collapse
Affiliation(s)
- Michelle L Hughes
- Department of Special Education and Communication Disorders, University of Nebraska-Lincoln, 276 Barkley Memorial Center, Lincoln, NE, 68583, USA.
| |
Collapse
|
24
|
A Broadly Applicable Method for Characterizing the Slope of the Electrically Evoked Compound Action Potential Amplitude Growth Function. Ear Hear 2022; 43:150-164. [PMID: 34241983 PMCID: PMC8674380 DOI: 10.1097/aud.0000000000001084] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Amplitudes of electrically evoked compound action potentials (eCAPs) as a function of the stimulation level constitute the eCAP amplitude growth function (AGF). The slope of the eCAP AGF (i.e., rate of growth of eCAP amplitude as a function of stimulation level), recorded from subjects with cochlear implants (CIs), has been widely used as an indicator of survival of cochlear nerve fibers. However, substantial variation in the approach used to calculate the slope of the eCAP AGF makes it difficult to compare results across studies. In this study, we developed an improved slope-fitting method by addressing the limitations of previously used approaches and ensuring its application for the estimation of the maximum slopes of the eCAP AGFs recorded in both animal models and human listeners with various etiologies. DESIGN The new eCAP AGF fitting method was designed based on sliding window linear regression. Slopes of the eCAP AGF estimated using this new fitting method were calculated and compared with those estimated using four other fitting methods reported in the literature. These four methods were nonlinear regression with a sigmoid function, linear regression, gradient calculation, and boxcar smoothing. The comparison was based on the fitting results of 72 eCAP AGFs recorded from 18 acutely implanted guinea pigs, 46 eCAP AGFs recorded from 23 chronically implanted guinea pigs, and 2094 eCAP AGFs recorded from 200 human CI users from 4 patient populations. The effect of the choice of input units of the eCAP AGF (linear versus logarithmic) on fitting results was also evaluated. RESULTS The slope of the eCAP AGF was significantly influenced by the slope-fitting method and by the choice of input units. Overall, slopes estimated using all five fitting methods reflected known patterns of neural survival in human patient populations and were significantly correlated with speech perception scores. However, slopes estimated using the newly developed method showed the highest correlation with spiral ganglion neuron density among all five fitting methods for animal models. In addition, this new method could reliably and accurately estimate the slope for 4 human patient populations, while the performance of the other methods was highly influenced by the morphology of the eCAP AGF. CONCLUSIONS The novel slope-fitting method presented in this study addressed the limitations of the other methods reported in the literature and successfully characterized the slope of the eCAP AGF for various animal models and CI patient populations. This method may be useful for researchers in conducting scientific studies and for clinicians in providing clinical care for CI users.
Collapse
|
25
|
Assessing the relationship between neural health measures and speech performance with simultaneous electric stimulation in cochlear implant listeners. PLoS One 2021; 16:e0261295. [PMID: 34898654 PMCID: PMC8668108 DOI: 10.1371/journal.pone.0261295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 11/29/2021] [Indexed: 11/19/2022] Open
Abstract
Objectives The relationship between electrode-nerve interface (ENI) estimates and inter-subject differences in speech performance with sequential and simultaneous channel stimulation in adult cochlear implant listeners were explored. We investigated the hypothesis that individuals with good ENIs would perform better with simultaneous compared to sequential channel stimulation speech processing strategies than those estimated to have poor ENIs. Methods Fourteen postlingually deaf implanted cochlear implant users participated in the study. Speech understanding was assessed with a sentence test at signal-to-noise ratios that resulted in 50% performance for each user with the baseline strategy F120 Sequential. Two simultaneous stimulation strategies with either two (Paired) or three sets of virtual channels (Triplet) were tested at the same signal-to-noise ratio. ENI measures were estimated through: (I) voltage spread with electrical field imaging, (II) behavioral detection thresholds with focused stimulation, and (III) slope (IPG slope effect) and 50%-point differences (dB offset effect) of amplitude growth functions from electrically evoked compound action potentials with two interphase gaps. Results A significant effect of strategy on speech understanding performance was found, with Triplets showing a trend towards worse speech understanding performance than sequential stimulation. Focused thresholds correlated positively with the difference required to reach most comfortable level (MCL) between Sequential and Triplet strategies, an indirect measure of channel interaction. A significant offset effect (difference in dB between 50%-point for higher eCAP growth function slopes with two IPGs) was observed. No significant correlation was observed between the slopes for the two IPGs tested. None of the measures used in this study correlated with the differences in speech understanding scores between strategies. Conclusions The ENI measure based on behavioral focused thresholds could explain some of the difference in MCLs, but none of the ENI measures could explain the decrease in speech understanding with increasing pairs of simultaneously stimulated electrodes in processing strategies.
Collapse
|
26
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
27
|
Electrically evoked auditory brainstem responses to electrical stimulation at round window membrane in congenitally deaf children at different ages. Int J Pediatr Otorhinolaryngol 2021; 148:110821. [PMID: 34225082 DOI: 10.1016/j.ijporl.2021.110821] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/24/2021] [Accepted: 06/29/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To investigate the usefulness of measuring the electrically evoked auditory brainstem responses (eABRs) to electrical stimulation at the round window niche (RWN) and round window membrane (RWM) and the effect of deafness duration on functions of the auditory pathway to the level of the brainstem. METHODS According to the age at cochlear implantation (CI), 99 children with profound sensorineural hearing loss were divided into four groups: ≤12 months (group A), 13-36 months (group B), 37-60 months (group C) and >60 months (group D). The eABRs were evoked by electrical stimulation at RWN and RWM during the operation of CI. RESULTS The higher eABR extraction rate and lower threshold for RWM stimulation was found than those for RWN stimulation. The eⅢ latencies and eⅢ-eⅤ latency intervals for RWM stimulation were similar among four groups. However, children with earlier CI (group A) showed a significantly shorter eⅤ latency than others. CONCLUSION The eABR evoked by the electrical stimulation at RWM is more stable and sensitive compared with that at RWN for evaluating functions of the auditory conduction pathway. Development in the upper brainstem pathway may be more vulnerable to long-term deafness as revealed by the eⅤ latency.
Collapse
|
28
|
He S, Xu L, Skidmore J, Chao X, Riggs WJ, Wang R, Vaughan C, Luo J, Shannon M, Warner C. Effect of Increasing Pulse Phase Duration on Neural Responsiveness of the Electrically Stimulated Cochlear Nerve. Ear Hear 2021; 41:1606-1618. [PMID: 33136636 PMCID: PMC7529657 DOI: 10.1097/aud.0000000000000876] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study is to (1) investigate the effects of increasing the pulse phase duration (PPD) on the neural response of the electrically stimulated cochlear nerve (CN) in children with CN deficiency (CND) and (2) compare the results from the CND population to those measured in children with normal-sized CNs. DESIGN Study participants included 30 children with CND and 30 children with normal-sized CNs. All participants used a Cochlear Nucleus device in the test ear. For each subject, electrically evoked compound action potential (eCAP) input/output (I/O) functions evoked by single biphasic pulses with different PPDs were recorded at three electrode locations across the electrode array. PPD durations tested in this study included 50, 62, 75, and 88 μsec/phase. For each electrode tested for each study participant, the amount of electrical charge corresponding to the maximum comfortable level measured for the 88 μsec PPD was used as the upper limit of stimulation. The eCAP amplitude measured at the highest electrical charge level, the eCAP threshold (i.e., the lowest level that evoked an eCAP), and the slope of the eCAP I/O function were measured. Generalized linear mixed effect models with study group, electrode location, and PPD as the fixed effects and subject as the random effect were used to compare these dependent variables measured at different electrode locations and PPDs between children with CND and children with normal-sized CNs. RESULTS Children with CND had smaller eCAP amplitudes, higher eCAP thresholds, and smaller slopes of the eCAP I/O function than children with normal-sized CNs. Children with CND who had fewer electrodes with a measurable eCAP showed smaller eCAP amplitudes and flatter eCAP I/O functions than children with CND who had more electrodes with eCAPs. Increasing the PPD did not show a statistically significant effect on any of these three eCAP parameters in the two subject groups tested in this study. CONCLUSIONS For the same amount of electrical charge, increasing the PPD from 50 to 88 μsec for a biphasic pulse with a 7 μsec interphase gap did not significantly affect CN responsiveness to electrical stimulation in human cochlear implant users. Further studies with different electrical pulse configurations are warranted to determine whether evaluating the eCAP sensitivity to changes in the PPD can be used as a testing paradigm to estimate neural survival of the CN for individual cochlear implant users.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Lei Xu
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Xiuhua Chao
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - William J. Riggs
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Ruijie Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Chloe Vaughan
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Jianfen Luo
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Michelle Shannon
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Cynthia Warner
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| |
Collapse
|
29
|
The Effects of GJB2 or SLC26A4 Gene Mutations on Neural Response of the Electrically Stimulated Auditory Nerve in Children. Ear Hear 2021; 41:194-207. [PMID: 31124793 DOI: 10.1097/aud.0000000000000744] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study aimed to (1) investigate the effect of GJB2 and SLC26A4 gene mutations on auditory nerve function in pediatric cochlear implant users and (2) compare their results with those measured in implanted children with idiopathic hearing loss. DESIGN Participants included 20 children with biallelic GJB2 mutations, 16 children with biallelic SLC26A4 mutations, and 19 children with idiopathic hearing loss. All subjects except for two in the SLC26A4 group had concurrent Mondini malformation and enlarged vestibular aqueduct. All subjects used Cochlear Nucleus devices in their test ears. For each subject, electrophysiological measures of the electrically evoked compound action potential (eCAP) were recorded using both anodic- and cathodic-leading biphasic pulses. Dependent variables (DVs) of interest included slope of eCAP input/output (I/O) function, the eCAP threshold, and eCAP amplitude measured at the maximum comfortable level (C level) of the anodic-leading stimulus (i.e., the anodic C level). Slopes of eCAP I/O functions were estimated using statistical modeling with a linear regression function. These DVs were measured at three electrode locations across the electrode array. Generalized linear mixed effect models were used to evaluate the effects of study group, stimulus polarity, and electrode location on each DV. RESULTS Steeper slopes of eCAP I/O function, lower eCAP thresholds, and larger eCAP amplitude at the anodic C level were measured for the anodic-leading stimulus compared with the cathodic-leading stimulus in all subject groups. Children with GJB2 mutations showed steeper slopes of eCAP I/O function and larger eCAP amplitudes at the anodic C level than children with SLC26A4 mutations and children with idiopathic hearing loss for both the anodic- and cathodic-leading stimuli. In addition, children with GJB2 mutations showed a smaller increase in eCAP amplitude when the stimulus changed from the cathodic-leading pulse to the anodic-leading pulse (i.e., smaller polarity effect) than children with idiopathic hearing loss. There was no statistically significant difference in slope of eCAP I/O function, eCAP amplitude at the anodic C level, or the size of polarity effect on all three DVs between children with SLC26A4 mutations and children with idiopathic hearing loss. These results suggested that better auditory nerve function was associated with GJB2 but not with SLC26A4 mutations when compared with idiopathic hearing loss. In addition, significant effects of electrode location were observed for slope of eCAP I/O function and the eCAP threshold. CONCLUSIONS GJB2 and SLC26A4 gene mutations did not alter polarity sensitivity of auditory nerve fibers to electrical stimulation. The anodic-leading stimulus was generally more effective in activating auditory nerve fibers than the cathodic-leading stimulus, despite the presence of GJB2 or SLC26A4 mutations. Patients with GJB2 mutations appeared to have better functional status of the auditory nerve than patients with SLC26A4 mutations who had concurrent Mondini malformation and enlarged vestibular aqueduct and patients with idiopathic hearing loss.
Collapse
|
30
|
Xu L, Skidmore J, Luo J, Chao X, Wang R, Wang H, He S. The Effect of Pulse Polarity on Neural Response of the Electrically Stimulated Cochlear Nerve in Children With Cochlear Nerve Deficiency and Children With Normal-Sized Cochlear Nerves. Ear Hear 2021; 41:1306-1319. [PMID: 32141933 PMCID: PMC7879579 DOI: 10.1097/aud.0000000000000854] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE This study aimed to (1) investigate the effect of pulse polarity on neural response of the electrically stimulated cochlear nerve in children with cochlear nerve deficiency (CND) and children with normal-sized cochlear nerves and (2) compare the size of the pulse polarity effect between these two subject groups. DESIGN The experimental and control group included 31 children with CND and 31 children with normal-sized cochlear nerves, respectively. For each study participant, evoked compound action potential (eCAP) input/output (I/O) functions for anodic-leading and cathodic-leading biphasic stimuli were measured at three electrode locations across the electrode array. The dependent variables of interest included the eCAP amplitude measured at the maximum comfortable level of the anodic stimulus, the lowest level that could evoke an eCAP (i.e., the eCAP threshold), the slope of the eCAP I/O function estimated based on linear regression, the negative-peak (i.e., N1) latency of the eCAP, as well as the size of the pulse polarity effect on these eCAP measurements. Generalized linear mixed effect models were used to compare the eCAP amplitude, the eCAP threshold, the slope of the eCAP I/O function, and the N1 latency evoked by the anodic-leading stimulus with those measured for the cathodic-leading stimulus for children with CND and children with normal-sized cochlear nerves. Generalized linear mixed effect models were also used to compare the size of the pulse polarity effect on the eCAP between these two study groups. The one-tailed Spearman correlation test was used to assess the potential correlation between the pulse phase duration and the difference in N1 latency measured for different pulse polarities. RESULTS Compared with children who had normal-sized cochlear nerves, children with CND had reduced eCAP amplitudes, elevated eCAP thresholds, flatter eCAP I/O functions, and prolonged N1 latencies. The anodic-leading stimulus led to higher eCAP amplitudes, lower eCAP thresholds, and shorter N1 latencies than the cathodic-leading stimulus in both study groups. Steeper eCAP I/O functions were recorded for the anodic-leading stimulus than those measured for the cathodic-leading stimulus in children with CND, but not in children with normal-sized cochlear nerves. Group differences in the size of the pulse polarity effect on the eCAP amplitude, the eCAP threshold, or the N1 latency were not statistically significant. CONCLUSIONS Similar to the normal-sized cochlear nerve, the hypoplastic cochlear nerve is more sensitive to the anodic-leading than to the cathodic-leading stimulus. Results of this study do not provide sufficient evidence for proving the idea that the pulse polarity effect can provide an indication for local neural health.
Collapse
Affiliation(s)
- Lei Xu
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Jianfen Luo
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Xiuhua Chao
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Ruijie Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Haibo Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| |
Collapse
|
31
|
Jahn KN, Arenberg JG. Electrophysiological Estimates of the Electrode-Neuron Interface Differ Between Younger and Older Listeners With Cochlear Implants. Ear Hear 2021; 41:948-960. [PMID: 32032228 PMCID: PMC10424265 DOI: 10.1097/aud.0000000000000827] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The primary objective of this study was to quantify differences in evoked potential correlates of spiral ganglion neuron (SGN) density between younger and older individuals with cochlear implants (CIs) using the electrically evoked compound action potential (ECAP). In human temporal bone studies and in animal models, SGN density is the lowest in older subjects and in those who experienced long durations of deafness during life. SGN density also varies as a function of age at implantation and hearing loss etiology. Taken together, it is likely that younger listeners who were deafened and implanted during childhood have denser populations of SGNs than older individuals who were deafened and implanted later in life. In animals, ECAP amplitudes, amplitude growth function (AGF) slopes, and their sensitivity to stimulus interphase gap (IPG) are predictive of SGN density. The authors hypothesized that younger listeners who were deafened and implanted as children would demonstrate larger ECAP amplitudes, steeper AGF slopes, and greater IPG sensitivity than older, adult-deafened and implanted listeners. DESIGN Data were obtained from 22 implanted ears (18 individuals). Thirteen ears (9 individuals) were deafened and implanted as children (child-implanted group), and nine ears (9 individuals) were deafened and implanted as adults (adult-implanted group). The groups differed significantly on a number of demographic variables that are implicitly related to SGN density: (1) chronological age; (2) age at implantation; and (3) duration of preimplantation hearing loss. ECAP amplitudes, AGF linear slopes, and thresholds were assessed on a subset of electrodes in each ear in response to two IPGs (7 and 30 µsec). Speech recognition was assessed using a medial vowel identification task. RESULTS Compared with the adult-implanted listeners, individuals in the child-implanted group demonstrated larger changes in ECAP amplitude when the IPG of the stimulus was increased from 7 to 30 µsec (i.e., greater IPG sensitivity). On average, child-implanted participants also had larger ECAP amplitudes and steeper AGF linear slopes than the adult-implanted participants, irrespective of IPG. IPG sensitivity for AGF linear slope and ECAP threshold did not differ between age groups. Vowel recognition performance was not correlated with any of the ECAP measures assessed in this study. CONCLUSIONS The results of this study support the theory that young CI listeners who were deafened and implanted during childhood may have denser neural populations than older listeners who were deafened and implanted as adults. Potential between-group differences in SGN integrity emphasize a need to investigate optimized CI programming parameters for younger and older listeners.
Collapse
Affiliation(s)
- Kelly N. Jahn
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| | - Julie G. Arenberg
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| |
Collapse
|
32
|
Jahn KN, Arenberg JG. Identifying Cochlear Implant Channels With Relatively Poor Electrode-Neuron Interfaces Using the Electrically Evoked Compound Action Potential. Ear Hear 2021; 41:961-973. [PMID: 31972772 PMCID: PMC10443089 DOI: 10.1097/aud.0000000000000844] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The primary objective of this study was to quantify local (within ear) and global (between ear) variation in the cochlear implant (CI) electrode-neuron interface (ENI) using the electrically evoked compound action potential (ECAP). We tested the hypothesis that, within an ear, ECAP measures can be used to identify channels with presumed good and poor ENIs, which may be influenced by a combination of spiral ganglion neuron (SGN) density, electrode position, and cochlear resistivity. We also hypothesized that ECAP responses would reflect age-related differences in the global quality of the ENI between younger and older listeners who theoretically differ in SGN density. DESIGN Data were obtained from 18 implanted ears (13 individuals) with Advanced Bionics HiRes 90K devices. Six participants (8 ears) were adolescents or young adults (age range: 14-32 years), and 7 participants (10 ears) were older adults (age range: 54-88 years). In each ear, single-channel auditory detection thresholds were measured on channels 2 through 15 in response to a spatially focused electrode configuration (steered quadrupolar; focusing coefficient = 0.9). ECAP amplitudes, amplitude growth function (AGF) slopes, and thresholds were assessed on a subset of channels in each ear in response to three interphase gaps (0, 7, and 30 µs). ECAP peak amplitudes were assessed on all channels between 2 and 15. AGFs and ECAP thresholds were measured on the two nonadjacent channels with the lowest and highest focused behavioral thresholds in each ear. ECAP responses were compared across low- and high-threshold channels and between younger and older CI listeners. RESULTS Channels that were estimated to interface poorly with the auditory nerve (i.e., high-focused-threshold channels) had steeper ECAP AGF slopes, smaller dynamic ranges, and higher ECAP thresholds than channels with low focused thresholds. Younger listeners had steeper ECAP AGF slopes and larger ECAP peak amplitudes than older listeners. Moreover, younger listeners showed greater interphase gap sensitivity for ECAP amplitude than older listeners. CONCLUSIONS ECAP responses may be used to quantify both local (within ear) and global (between ear) variation in the quality of the ENI. Results of this study support future investigation into the use of ECAP responses in site-selection CI programming strategies. The present results also support a growing body of evidence suggesting that adolescents and young adults with CIs may have denser populations of functional SGNs relative to older adults. Potential differences in global SGN integrity between younger and older listeners warrant investigation of optimal CI programming interventions based on their divergent hearing histories.
Collapse
Affiliation(s)
- Kelly N. Jahn
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| | - Julie G. Arenberg
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| |
Collapse
|
33
|
He S, Xu L, Skidmore J, Chao X, Jeng FC, Wang R, Luo J, Wang H. The Effect of Interphase Gap on Neural Response of the Electrically Stimulated Cochlear Nerve in Children With Cochlear Nerve Deficiency and Children With Normal-Sized Cochlear Nerves. Ear Hear 2021; 41:918-934. [PMID: 31688319 PMCID: PMC7211427 DOI: 10.1097/aud.0000000000000815] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES This study aimed to compare the effects of increasing the interphase gap (IPG) on the neural response of the electrically stimulated cochlear nerve (CN) between children with CN deficiency (CND) and children with normal-sized CNs. DESIGN Study participants included 30 children with CND and 30 children with normal-sized CNs. All subjects were implanted with a Cochlear Nucleus device with the internal electrode array 24RE[CA] in the test ear. The stimulus was a charge-balanced, cathodic leading, biphasic pulse with a pulse-phase duration of 50 μsec. For each subject, the electrically evoked compound action potential (eCAP) input/output (I/O) function was measured for 6 IPGs (i.e., 7, 14, 21, 28, 35, and 42 μsec) at 3 electrode locations across the electrode array. For each subject and each testing electrode, the highest stimulation used to measure the eCAP I/O function was the maximum comfortable level measured with an IPG of 42 μsec. Dependent variables (DVs) were the maximum eCAP amplitude, the eCAP threshold, and the slope of the eCAP I/O function estimated using both linear and sigmoidal regression functions. For each DV, the size of the IPG effect was defined as the proportional change relative to the result measured for the 7 μsec IPG at the basal electrode location. Generalized linear mixed effect models with subject group, electrode location, and IPG duration as the fixed effects and subject as the random effect were used to compare these DVs and the size of the IPG effect on these DVs. RESULTS Children with CND showed smaller maximum eCAP amplitudes, higher eCAP thresholds, and smaller slopes of eCAP I/O function estimated using either linear or sigmoidal regression function than children with normal-sized CNs. Increasing the IPG duration resulted in larger maximum eCAP amplitudes, lower eCAP thresholds and larger slopes of eCAP I/O function estimated using sigmoidal regression function at all three electrode locations in both study groups. Compared with children with normal-sized CNs, children with CND showed larger IPG effects on both the maximum eCAP amplitude and the slope of the eCAP I/O function estimated using either linear or sigmoidal regression function, and a smaller IPG effect on the eCAP threshold than those measured in children with normal-sized CNs. CONCLUSIONS Increasing the IPG increases responsiveness of the electrically stimulated CN in both children with CND and children with normal-sized CNs. The maximum eCAP amplitude and the slope of the eCAP I/O function measured in human listeners with poorer CN survival are more sensitive to changes in the IPG. In contrast, the eCAP threshold in listeners with poorer CN survival is less sensitive to increases in the IPG. Further studies are warranted to identify the best parameters of eCAP results for predicting CN survival before this eCAP testing paradigm can be used as a clinical tool for evaluating neural health for individual cochlear implant patients.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Lei Xu
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Xiuhua Chao
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Fuh-Cherng Jeng
- Department of Communication Sciences and Disorders, Ohio University, Ohio University Drive, Athens, OH 45701
| | - Ruijie Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Jianfen Luo
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Haibo Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| |
Collapse
|
34
|
Imsiecke M, Büchner A, Lenarz T, Nogueira W. Amplitude Growth Functions of Auditory Nerve Responses to Electric Pulse Stimulation With Varied Interphase Gaps in Cochlear Implant Users With Ipsilateral Residual Hearing. Trends Hear 2021; 25:23312165211014137. [PMID: 34181493 PMCID: PMC8243142 DOI: 10.1177/23312165211014137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Amplitude growth functions (AGFs) of electrically evoked compound action
potentials (eCAPs) with varying interphase gaps (IPGs) were measured in cochlear
implant users with ipsilateral residual hearing (electric-acoustic stimulation
[EAS]). It was hypothesized that IPG effects on AGFs provide an objective
measure to estimate neural health. This hypothesis was tested in EAS users, as
residual low-frequency hearing might imply survival of hair cells and hence
better neural health in apical compared to basal cochlear regions. A total of 16
MED-EL EAS subjects participated, as well as a control group of 16 deaf cochlear
implant users. The IPG effect on the AGF characteristics of slope, threshold,
dynamic range, and stimulus level at 50% maximum eCAP amplitude
(level50%) was investigated. AGF threshold and
level50% were significantly affected by the IPG in both EAS and
control group. The magnitude of AGF characteristics correlated with electrode
impedance and electrode-modiolus distance (EMD) in both groups. In contrast, the
change of the AGF characteristics with increasing IPG was independent of these
electrode-specific measures. The IPG effect on the AGF level50% in
both groups, as well as on the threshold in EAS users, correlated with the
duration of hearing loss, which is a predictor of neural health. In EAS users, a
significantly different IPG effect on level50% was found between
apical and medial electrodes. This outcome is consistent with our hypothesis
that the influence of IPG effects on AGF characteristics provides a sensitive
measurement and may indicate better neural health in the apex compared to the
medial cochlear region in EAS users.
Collapse
Affiliation(s)
- Marina Imsiecke
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| | - Thomas Lenarz
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| | - Waldo Nogueira
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| |
Collapse
|
35
|
Radeloff A, Nada N, El Mahallawi T, Kolkaila E, Vollmer M, Rak K, Hagen R, Schendzielorz P. Transplantation of adipose-derived stromal cells protects functional and morphological auditory nerve integrity in a model of cochlear implantation. Neuroreport 2021; 32:776-782. [PMID: 33994529 DOI: 10.1097/wnr.0000000000001651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Cochlear implants are considered the gold standard therapy for subjects with severe hearing loss and deafness. Cochlear implants bypass the damaged hair cells and directly stimulate spiral ganglion neurons (SGNs) of the auditory nerve. Hence, the presence of functional SGNs is crucial for speech perception in electric hearing with a cochlear implant. In deaf individuals, SGNs progressively degenerate due to the lack of neurotrophic support, normally provided by sensory cells of the inner ear. Adipose-derived stromal cells (ASCs) are known to produce neurotrophic factors. In a guinea pig model of sensory hearing loss and cochlear implantation, ASCs were autologously transplanted into the scala tympani prior to insertion of a cochlear implant on one side. Electrically evoked auditory brain stem responses (eABR) were recorded 8 weeks after cochlear implantation. At conclusion of the experiment, the cochleae were histologically evaluated. Compared to untreated control animals, transplantation of ASCs resulted in an increased number of SGNs and their peripheral neurites. In ASC-transplanted animals, mean eABR thresholds were lower and suprathreshold amplitudes larger, suggesting a larger population of intact auditory nerve fibers. Moreover, when compared to controls, amplitude-level functions of eABRs in ASC transplanted animals demonstrated steeper slopes in response to increasing interphase gaps (IPGs), indicative of better functionality of the auditory nerve. In summary, results suggest that transplantation of autologous ASCs into the deaf inner ear may have protective effects on the survival of SGNs and their peripheral processes and may thus contribute to long-term benefits in speech discrimination performance in cochlear implant subjects.
Collapse
Affiliation(s)
- Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Head and Neck Surgery, Carl von Ossietzky-University
- Cluster of excellence "Hearing 4 All"
- Research Center Neurosensory Science, Oldenburg, Germany
| | - Nashwa Nada
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Tanta University Hospitals, Tanta, Egypt
| | - Trandil El Mahallawi
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Tanta University Hospitals, Tanta, Egypt
| | - Enaas Kolkaila
- Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Tanta University Hospitals, Tanta, Egypt
| | - Maike Vollmer
- Department of Otol-Rhino-Laryngology, Head and Neck Surgery, University Magdeburg and Leibniz Institute for Neurobiology, Magdeburg
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Würzburg, Germany
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Würzburg, Germany
| | - Philipp Schendzielorz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University of Würzburg, Germany
| |
Collapse
|
36
|
Schvartz-Leyzac KC, Zwolan TA, Pfingst BE. Using the electrically-evoked compound action potential (ECAP) interphase gap effect to select electrode stimulation sites in cochlear implant users. Hear Res 2021; 406:108257. [PMID: 34020316 DOI: 10.1016/j.heares.2021.108257] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 03/25/2021] [Accepted: 04/19/2021] [Indexed: 10/21/2022]
Abstract
Studies in cochlear implanted animals show that the IPG Effect for ECAP growth functions (i.e., the magnitude of the change in ECAP amplitude growth function (AGF) slope or peak amplitude when the interphase gap (IPG) is increased) can be used to estimate the densities of spiral ganglion neurons (SGNs) near the electrode stimulation and recording sites. In humans, the same ECAP IPG Effect measures correlate with speech recognition performance. The present study examined the efficacy of selecting electrode sites for stimulation based on the IPG Effect, in order to improve performance of CI users on speech recognition tasks. We measured the ECAP IPG Effect for peak amplitude in adult (>18 years old) CI users (N= 18 ears), and created experimental programs to stimulate electrodes with either the highest or lowest ECAP IPG Effect for peak amplitude. Subjects also listened to a program without any electrodes deactivated. In a subset of subject ears (11/18), we compared performance differences between the experimental programs to post-operative computerized tomography (CT) scans to examine underlying factors that might contribute to the efficacy of an electrode site-selection approach. For sentences-in-noise, average performance was better when subjects listened to the experimental program that stimulated electrodes with the highest rather than the lowest IPG Effect for ECAP peak amplitude. A similar pattern was noted for transmission and perception of consonant place cues in a consonant recognition task. However, on average, performance when listening to a program with higher IPG Effect values was equal to that when listening with all electrodes activated. Results also suggest that scalar location (scala tympani or vestibuli) should be considered when using an ECAP-based electrode site-selection procedure to optimize CI performance.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, United States; Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI 48108, United States.
| | - Teresa A Zwolan
- Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI 48108, United States
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, United States
| |
Collapse
|
37
|
The Panoramic ECAP Method: Estimating Patient-Specific Patterns of Current Spread and Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2021; 22:567-589. [PMID: 33891218 PMCID: PMC8476702 DOI: 10.1007/s10162-021-00795-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 03/04/2021] [Indexed: 11/24/2022] Open
Abstract
The knowledge of patient-specific neural excitation patterns from cochlear implants (CIs) can provide important information for optimizing efficacy and improving speech perception outcomes. The Panoramic ECAP (‘PECAP’) method (Cosentino et al. 2015) uses forward-masked electrically evoked compound action-potentials (ECAPs) to estimate neural activation patterns of CI stimulation. The algorithm requires ECAPs be measured for all combinations of probe and masker electrodes, exploiting the fact that ECAP amplitudes reflect the overlapping excitatory areas of both probes and maskers. Here we present an improved version of the PECAP algorithm that imposes biologically realistic constraints on the solution, that, unlike the previous version, produces detailed estimates of neural activation patterns by modelling current spread and neural health along the intracochlear electrode array and is capable of identifying multiple regions of poor neural health. The algorithm was evaluated for reliability and accuracy in three ways: (1) computer-simulated current-spread and neural-health scenarios, (2) comparisons to psychophysical correlates of neural health and electrode-modiolus distances in human CI users, and (3) detection of simulated neural ‘dead’ regions (using forward masking) in human CI users. The PECAP algorithm reliably estimated the computer-simulated scenarios. A moderate but significant negative correlation between focused thresholds and the algorithm’s neural-health estimates was found, consistent with previous literature. It also correctly identified simulated ‘dead’ regions in all seven CI users evaluated. The revised PECAP algorithm provides an estimate of neural excitation patterns in CIs that could be used to inform and optimize CI stimulation strategies for individual patients in clinical settings.
Collapse
|
38
|
Eickhoff S, Jarvis JC. Pulse Shaping Strategies for Electroceuticals: A Comprehensive Survey of the Use of Interphase Gaps in Miniature Stimulation Systems. IEEE Trans Biomed Eng 2021; 68:1658-1667. [PMID: 33651679 DOI: 10.1109/tbme.2021.3063029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Interphase gaps (IPGs) are among the most commonly suggested pulse shape variations to try to enhance neural stimulation efficiency by reducing the action potential (AP) suppressing effect of an early anodic hyperpolarization. The majority of published literature on the effect of IPGs is based on investigations of monopolar stimulation configurations. However, many contemporary neuromodulation applications including the emerging field of electroceutical devices operate in a bipolar electrode configuration. METHODS We investigated the effect of IPGs and asymmetric biphasic current controlled pulses with reduced anodic amplitude on neural activation in both principal electrode configurations in a rodent in-vivo nerve muscle preparation. RESULTS In the monopolar electrode configuration, our findings of 10.9 ± 1.5% decreased stimulation amplitude with 200 μs IPGs in biphasic pulses of 40 μs phase width are in agreement with published literature in this configuration. Surprisingly, using the bipolar configuration, opposite effects of IPGs were observed and neural activation required up to 18.6 ± 3.1% (phase width 100 μs, IPG = 1000 μs) higher amplitudes. Electroneurogram recordings of the stimulated nerve revealed temporal differences in AP generation between the monopolar and bipolar configuration. In the bipolar configuration excitation first occurred in response to the middle field transition of biphasic pulses. CONCLUSION This is the first study to report consistently increased amplitude requirements with IPGs in bipolar stimulation configurations. SIGNIFICANCE Our findings must be taken into consideration when designing stimulation waveforms for neuromodulation devices that operate in a bipolar mode to avoid increased amplitude requirements that result in increased energy consumption.
Collapse
|
39
|
Colesa DJ, Devare J, Swiderski DL, Beyer LA, Raphael Y, Pfingst BE. Development of a chronically-implanted mouse model for studies of cochlear health and implant function. Hear Res 2021; 404:108216. [PMID: 33691255 DOI: 10.1016/j.heares.2021.108216] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 02/12/2021] [Accepted: 02/16/2021] [Indexed: 01/16/2023]
Abstract
Mice with chronic cochlear implants can significantly contribute to our understanding of the relationship between cochlear health and implant function because of the availability of molecular tools for controlling conditions in the cochlea and transgenic lines modeling human disease. To date, research in implanted mice has mainly consisted of short-term studies, but since there are large changes in implant function following implant insertion trauma, and subsequent recovery in many cases, longer-term studies are needed to evaluate function and perception under stable conditions. Because frequent anesthetic administration can be especially problematic in mice, a chronic model that can be tested in the awake condition is desirable. Electrically-evoked compound action potentials (ECAPs) recorded with multichannel cochlear implants are useful functional measures because they can be obtained daily without anesthesia. In this study, we assessed changes and stability of ECAPs, electrically-evoked auditory brainstem responses (EABRs), ensemble spontaneous activity (ESA), and impedance data over time after implanting mice with multichannel implants. We then compared these data to histological findings in these implanted cochleae, and compared results from this chronic mouse model to data previously obtained in a well-established chronically-implanted guinea pig model. We determined that mice can be chronically implanted with cochlear implants, and ECAP recordings can be obtained frequently in an awake state for up to at least 42 days after implantation. These recordings can effectively monitor changes or stability in cochlear function over time. ECAP and EABR amplitude-growth functions (AGFs), AGF slopes, ESA levels and impedances in mice with multichannel implants appear similar to those found in guinea pigs with long-term multichannel implants. Animals with better survival of spiral ganglion neurons (SGNs) and inner hair cells (IHCs) have steeper AGF slopes, and larger ESA responses. The time course of post-surgical ear recovery may be quicker in mice and can show different patterns of recovery which seem to be dependent on the degree of insertion trauma and subsequent histological conditions. Histology showed varying degrees of cochlear damage with fibrosis present in all implanted mouse ears and small amounts of new bone in a few ears. Impedance changes over time varied within and across animals and may represent changes over time in multiple variables in the cochlear environment post-implantation. Due to the small size of the mouse, susceptibility to stress, and the higher potential for implant failure, chronic implantation in mice can be challenging, but overall is feasible and useful for cochlear implant research.
Collapse
Affiliation(s)
- Deborah J Colesa
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA
| | - Jenna Devare
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA
| | - Donald L Swiderski
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA
| | - Lisa A Beyer
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA
| | - Yehoash Raphael
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, 1150 West Medical Center Drive, University of Michigan, Ann Arbor 48109-5616, MI, USA.
| |
Collapse
|
40
|
Zhou N, Zhu Z, Dong L, Galvin J. Sensitivity to Pulse Phase Duration as a Marker of Neural Health Across Cochlear Implant Recipients and Electrodes. J Assoc Res Otolaryngol 2021; 22:177-192. [PMID: 33559041 PMCID: PMC7943680 DOI: 10.1007/s10162-021-00784-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 01/03/2021] [Indexed: 11/19/2022] Open
Abstract
In cochlear implants, loudness has been shown to grow more slowly with increasing pulse phase duration (PPD) than with pulse amplitude (PA), possibly due to “leaky” charge integration. This leakiness has been recently quantified in terms of “charge integration efficiency,” defined as the log difference between the PPD dynamic range and PA dynamic range (both expressed in charge units), relative to a common threshold anchor. Such leakiness may differ across electrodes and/or test ears, and may reflect underlying neural health. In this study, we examined the across-site variation of charge integration in recipients of Cochlear© devices. PPD and PA dynamic ranges were measured relative to two threshold anchors with either a 25- or 50-microsecond PPD. Strength-duration functions, previously shown to relate to survival of spiral ganglion cells and peripheral processes, were compared to charge integration efficiency on selected electrodes. Results showed no significant or systematic relationship between the across-site variation in charge integration efficiency and electrode position or threshold levels. Charge integration efficiency was poorer with the 50-μs threshold anchor, suggesting that greater leakiness was associated with larger PPD dynamic ranges. Poorer and more variable charge integration efficiency across electrodes was associated with longer duration of any hearing loss, consistent with the idea that poor integration is related to neural degeneration. More variable integration efficiency was also associated with poorer speech recognition performance across test ears. The slopes of the strength-duration functions at maximum acceptable loudness were significantly correlated with charge integration efficiency. However, the strength-duration slopes were not predictive of duration of any hearing loss or speech recognition performance in our participants. As such, charge integration efficiency may be a better candidate to measure leakiness in neural populations across the electrode array, as well as the general health of the auditory nerve in human cochlear implant recipients.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - Zhen Zhu
- Department of Engineering, East Carolina University, Greenville, NC, 27834, USA
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - John Galvin
- House Ear Institute, 2100 W. Third St., Suite 101, Los Angeles, CA, 90057, USA.
| |
Collapse
|
41
|
McKay CM. Applications of Phenomenological Loudness Models to Cochlear Implants. Front Psychol 2021; 11:611517. [PMID: 33519626 PMCID: PMC7838155 DOI: 10.3389/fpsyg.2020.611517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 12/11/2020] [Indexed: 11/13/2022] Open
Abstract
Cochlear implants electrically stimulate surviving auditory neurons in the cochlea to provide severely or profoundly deaf people with access to hearing. Signal processing strategies derive frequency-specific information from the acoustic signal and code amplitude changes in frequency bands onto amplitude changes of current pulses emitted by the tonotopically arranged intracochlear electrodes. This article first describes how parameters of the electrical stimulation influence the loudness evoked and then summarizes two different phenomenological models developed by McKay and colleagues that have been used to explain psychophysical effects of stimulus parameters on loudness, detection, and modulation detection. The Temporal Model is applied to single-electrode stimuli and integrates cochlear neural excitation using a central temporal integration window analogous to that used in models of normal hearing. Perceptual decisions are made using decision criteria applied to the output of the integrator. By fitting the model parameters to a variety of psychophysical data, inferences can be made about how electrical stimulus parameters influence neural excitation in the cochlea. The Detailed Model is applied to multi-electrode stimuli, and includes effects of electrode interaction at a cochlear level and a transform between integrated excitation and specific loudness. The Practical Method of loudness estimation is a simplification of the Detailed Model and can be used to estimate the relative loudness of any multi-electrode pulsatile stimuli without the need to model excitation at the cochlear level. Clinical applications of these models to novel sound processing strategies are described.
Collapse
Affiliation(s)
- Colette M. McKay
- Bionics Institute, Melbourne, VIC, Australia
- Department of Medical Bionics, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
42
|
Zhan KY, Adunka OF, Eshraghi A, Riggs WJ, Prentiss SM, Yan D, Telischi FF, Liu X, He S. Electrophysiology and genetic testing in the precision medicine of congenital deafness: A review. J Otol 2021; 16:40-46. [PMID: 33505449 PMCID: PMC7814082 DOI: 10.1016/j.joto.2020.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 07/11/2020] [Accepted: 07/21/2020] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Congenital hearing loss is remarkably heterogeneous, with over 130 deafness genes and thousands of variants, making for innumerable genotype/phenotype combinations. Understanding both the pathophysiology of hearing loss and molecular site of lesion along the auditory pathway permits for significantly individualized counseling. Electrophysiologic techniques such as electrocochleography (ECochG) and electrically-evoked compound action potentials (eCAP) are being studied to localize pathology and estimate residual cochlear vs. neural health. This review describes the expanding roles of genetic and electrophysiologic evaluation in the precision medicine of congenital hearing loss.The basics of genetic mutations in hearing loss and electrophysiologic testing (ECochG and eCAP) are reviewed, and how they complement each other in the diagnostics and prognostication of hearing outcomes. Used together, these measures improve the understanding of insults to the auditory system, allowing for individualized counseling for CI candidacy/outcomes or other habilitation strategies. CONCLUSION Despite tremendous discovery in deafness genes, the effects of individual genes on neural function remain poorly understood. Bridging the understanding between molecular genotype and neural and functional phenotype is paramount to interpreting genetic results in clinical practice. The future hearing healthcare provider must consolidate an ever-increasing amount of genetic and phenotypic information in the precision medicine of hearing loss.
Collapse
Affiliation(s)
- Kevin Y. Zhan
- Department of Otolaryngology – Head & Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Oliver F. Adunka
- Department of Otolaryngology – Head & Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
- Department of Audiology, Nationwide Children’s Hospital, Columbus, OH, USA
| | - Adrien Eshraghi
- Department of Otolaryngology – Head & Neck Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | - William J. Riggs
- Department of Otolaryngology – Head & Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
- Department of Audiology, Nationwide Children’s Hospital, Columbus, OH, USA
| | - Sandra M. Prentiss
- Department of Otolaryngology – Head & Neck Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Denise Yan
- Department of Otolaryngology – Head & Neck Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Fred F. Telischi
- Department of Otolaryngology – Head & Neck Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Xuezhong Liu
- Department of Otolaryngology – Head & Neck Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
- Dr. John T. MacDonald Foundation, Department of Human Genetics, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Shuman He
- Department of Otolaryngology – Head & Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
- Department of Audiology, Nationwide Children’s Hospital, Columbus, OH, USA
| |
Collapse
|
43
|
Shekar RCMC, Hansen JHL. An evaluation framework for research platforms to advance cochlear implant/hearing aid technology: A case study with CCi-MOBILE. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:229. [PMID: 33514127 PMCID: PMC7803384 DOI: 10.1121/10.0002989] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 12/06/2020] [Accepted: 12/09/2020] [Indexed: 06/12/2023]
Abstract
Cochlear implants (CIs) and hearing aids (HAs) are advanced assistive hearing devices that perform sound processing to achieve acoustic to acoustic/electrical stimulation, thus enabling the prospects for hearing restoration and rehabilitation. Since commercial CIs/HAs are typically constrained by manufacturer design/production constraints, it is necessary for researchers to use research platforms (RPs) to advance algorithms and conduct investigational studies with CI/HA subjects. While previous CI/HA research platforms exist, no study has explored establishing a formal evaluation protocol for the operational safety and reliability of RPs. This study proposes a two-phase analysis and evaluation paradigm for RPs. In the acoustic phase 1 step, a signal processing acoustic space is explored in order to present a sampled set of audio input content to explore the safety of the resulting output electric/acoustic stimulation. In the parameter phase 2 step, the configurable space for realizable electrical stimulation pulses is determined, and overall stimulation reliability and safety are evaluated. The proposed protocol is applied and demonstrated using Costakis Cochlear Implant Mobile. Assessment protocol observations, results, and additional best practices for subsampling of the acoustic and parameter test spaces are discussed. The proposed analysis-evaluation protocol establishes a viable framework for assessing RP operational safety and reliability. Guidelines for adapting the proposed protocol to address variability in RP configuration due to experimental factors such as custom algorithms, stimulation techniques, and/or individualization are also considered.
Collapse
Affiliation(s)
- Ram C M C Shekar
- Cochlear Implant Processing Laboratory, Center for Robust Speech Systems (CRSS-CILab), Department of Electrical and Computer Engineering, Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - John H L Hansen
- Cochlear Implant Processing Laboratory, Center for Robust Speech Systems (CRSS-CILab), Department of Electrical and Computer Engineering, Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080, USA
| |
Collapse
|
44
|
Lu T, Li Q, Zhang C, Chen M, Wang Z, Li S. The sensitivity of different methods for detecting abnormalities in auditory nerve function. Biomed Eng Online 2020; 19:7. [PMID: 32013979 PMCID: PMC6998811 DOI: 10.1186/s12938-020-0750-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 01/22/2020] [Indexed: 11/18/2022] Open
Abstract
Background Cochlear implants (CIs) have become important for the treatment of severe-to-profound sensorineural hearing loss (SNHL). Meanwhile, electrically evoked compound action potentials (ECAPs) and electrically evoked auditory brainstem responses (EABRs), which can be examined and evaluated with minimal patient cooperation, have become more reliable for tone measurement and speech recognition postoperatively. However, few studies have compared the electrophysiological characteristics of the auditory nerve using ECAPs and EABRs under different functional states of the auditory nerve (FSANs). We used guinea pig models in which six electrodes were implanted unilaterally with continuous electrical stimulation (ES) for 4 h. The amplitude growth functions (AGFs) of the alternating polarity ECAP (AP-ECAP) and forward-masking subtraction ECAP (FM-ECAP), as well as the EABR waves under “normal” and “abnormal” FSANs, were obtained. Results Both the AP-ECAP and FM-ECAP thresholds were significantly higher than those measured by EABR under both “normal” FSAN and “abnormal” FSANs (p < 0.05). There was a significant difference in the slope values between electrodes 1 and 2 and electrodes 3 and 4 in terms of the AP-ECAP under the “abnormal” FSAN (p < 0.05). The threshold gaps between the AP-ECAP and FM-ECAP were significantly larger under the “abnormal” FSAN than under the “normal” FSAN (p < 0.05). Conclusions Both of the ECAP thresholds were higher than the EABR thresholds. The AP-ECAP was more sensitive than the FM-ECAP under the “abnormal” FSAN.
Collapse
|
45
|
Guérit F, Marozeau J, Epp B, Carlyon RP. Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 21:497-510. [PMID: 32833160 PMCID: PMC7644659 DOI: 10.1007/s10162-020-00767-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 07/31/2020] [Indexed: 12/21/2022] Open
Abstract
The effect of the relative timing between pairs of same-polarity monophasic pulses has been studied extensively in single-neuron animal studies and has revealed fundamental properties of the neurons. For human cochlear implant listeners, the requirement to use charge-balanced stimulation and the typical use of symmetric, biphasic pulses limits such measures, because currents of opposite polarities interact at the level of the neural membrane. Here, we propose a paradigm to study same-polarity summation of currents while keeping the stimulation charge-balanced within a short time window. We used pairs of mirrored pseudo-monophasic pulses (a long-low phase followed by a short-high phase for the first pulse and a short-high phase followed by a long-low phase for the second pulse). We assumed that most of the excitation would stem from the two adjacent short-high phases, which had the same polarity. The inter-pulse interval between the short-high phases was varied from 0 to 345 μs. The inter-pulse interval had a significant effect on the perceived loudness, and this effect was consistent with both passive (membrane-related) and active (ion-channel-related) neuronal mechanisms contributing to facilitation. Furthermore, the effect of interval interacted with the polarity of the pulse pairs. At threshold, there was an effect of polarity, but, surprisingly, no effect of interval nor an interaction between the two factors. We discuss possible peripheral origins of these results.
Collapse
Affiliation(s)
- François Guérit
- Hearing Systems Group, Department of Health Technology, Technical University of Denmark, 352 Ørsteds Plads, 2800, Kgs. Lyngby, Denmark.
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, United Kingdom.
| | - Jeremy Marozeau
- Hearing Systems Group, Department of Health Technology, Technical University of Denmark, 352 Ørsteds Plads, 2800, Kgs. Lyngby, Denmark
| | - Bastian Epp
- Hearing Systems Group, Department of Health Technology, Technical University of Denmark, 352 Ørsteds Plads, 2800, Kgs. Lyngby, Denmark
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, United Kingdom
| |
Collapse
|
46
|
Schvartz-Leyzac KC, Colesa DJ, Buswinka CJ, Rabah AM, Swiderski DL, Raphael Y, Pfingst BE. How electrically evoked compound action potentials in chronically implanted guinea pigs relate to auditory nerve health and electrode impedance. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:3900. [PMID: 33379919 PMCID: PMC7863685 DOI: 10.1121/10.0002882] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 10/07/2020] [Accepted: 11/18/2020] [Indexed: 06/12/2023]
Abstract
This study examined how multiple measures based on the electrically evoked compound action potential (ECAP) amplitude-growth functions (AGFs) were related to estimates of neural [spiral ganglion neuron (SGN) density and cell size] and electrode impedance measures in 34 specific pathogen free pigmented guinea pigs that were chronically implanted (4.9-15.4 months) with a cochlear implant electrode array. Two interphase gaps (IPGs) were used for the biphasic pulses and the effect of the IPG on each ECAP measure was measured ("IPG effect"). When using a stimulus with a constant IPG, SGN density was related to the across-subject variance in ECAP AGF linear slope, peak amplitude, and N1 latency. The SGN density values also help to explain a significant proportion of variance in the IPG effect for AGF linear slope and peak amplitude measures. Regression modeling revealed that SGN density was the primary dependent variable contributing to across-subject variance for ECAP measures; SGN cell size did not significantly improve the fitting of the model. Results showed that simple impedance measures were weakly related to most ECAP measures but did not typically improve the fit of the regression model.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Deborah J Colesa
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Christopher J Buswinka
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Andrew M Rabah
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Donald L Swiderski
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Yehoash Raphael
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, Michigan 48109-5616, USA
| |
Collapse
|
47
|
Brochier T, Guérit F, Deeks JM, Garcia C, Bance M, Carlyon RP. Evaluating and Comparing Behavioural and Electrophysiological Estimates of Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 22:67-80. [PMID: 33150541 PMCID: PMC7822986 DOI: 10.1007/s10162-020-00773-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 10/14/2020] [Indexed: 12/12/2022] Open
Abstract
Variations in neural health along the cochlea can degrade the spectral and temporal representation of sounds conveyed by cochlear implants (CIs). We evaluated and compared one electrophysiological measure and two behavioural measures that have been proposed as estimates of neural health patterns, in order to explore the extent to which the different measures provide converging and consistent neural health estimates. All measures were obtained from the same 11 users of the Cochlear Corporation CI. The two behavioural measures were multipulse integration (MPI) and the polarity effect (PE), both measured on each of seven electrodes per subject. MPI was measured as the difference between thresholds at 80 pps and 1000 pps, and PE as the difference in thresholds between cathodic- and anodic-centred quadraphasic (QP) 80-pps pulse trains. It has been proposed that good neural health corresponds to a large MPI and to a large negative PE (lower thresholds for cathodic than anodic pulses). The electrophysiological measure was the effect of interphase gap (IPG) on the offset of the ECAP amplitude growth function (AGF), which has been correlated with spiral ganglion neuron density in guinea pigs. This 'IPG offset' was obtained on the same subset of electrodes used for the behavioural measures. Despite high test-retest reliability, there were no significant correlations between the neural health estimates for either within-subject comparisons across the electrode array, or between-subject comparisons of the means. A phenomenological model of a population of spiral ganglion neurons was then used to investigate physiological mechanisms that might underlie the different neural health estimates. The combined experimental and modelling results provide evidence that PE, MPI and IPG offset may reflect different characteristics of the electrode-neural interface.
Collapse
Affiliation(s)
- Tim Brochier
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK. .,Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Charlotte Garcia
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
48
|
BDNF Outperforms TrkB Agonist 7,8,3'-THF in Preserving the Auditory Nerve in Deafened Guinea Pigs. Brain Sci 2020; 10:brainsci10110787. [PMID: 33126525 PMCID: PMC7692073 DOI: 10.3390/brainsci10110787] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/23/2020] [Accepted: 10/27/2020] [Indexed: 02/06/2023] Open
Abstract
In deaf subjects using a cochlear implant (CI) for hearing restoration, the auditory nerve is subject to degeneration, which may negatively impact CI effectiveness. This nerve degeneration can be reduced by neurotrophic treatment. Here, we compare the preservative effects of the naturally occurring tyrosine receptor kinase B (TrkB) agonist brain-derived neurotrophic factor (BDNF) and the small-molecule TrkB agonist 7,8,3′-trihydroxyflavone (THF) on the auditory nerve in deafened guinea pigs. THF may be more effective than BDNF throughout the cochlea because of better pharmacokinetic properties. The neurotrophic compounds were delivered by placement of a gelatin sponge on the perforated round window membrane. To complement the histology of spiral ganglion cells (SGCs), electrically evoked compound action potential (eCAP) recordings were performed four weeks after treatment initiation. We analyzed the eCAP inter-phase gap (IPG) effect and measures derived from pulse-train evoked eCAPs, both indicative of SGC healthiness. BDNF but not THF yielded a significantly higher survival of SGCs in the basal cochlear turn than untreated controls. Regarding IPG effect and pulse-train responses, the BDNF-treated animals exhibited more normal responses than both untreated and THF-treated animals. We have thus confirmed the protective effect of BDNF, but we have not confirmed previously reported protective effects of THF with our clinically applicable delivery method.
Collapse
|
49
|
Brochier T, McKay CM, Carlyon RP. Interpreting the Effect of Stimulus Parameters on the Electrically Evoked Compound Action Potential and on Neural Health Estimates. J Assoc Res Otolaryngol 2020; 22:81-94. [PMID: 33108575 PMCID: PMC7823000 DOI: 10.1007/s10162-020-00774-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 10/14/2020] [Indexed: 02/03/2023] Open
Abstract
Variations in the condition of the neural population along the length of the cochlea can degrade the spectral and temporal representation of sounds conveyed by CIs, thereby limiting speech perception. One measurement that has been proposed as an estimate of neural survival (the number of remaining functional neurons) or neural health (the health of those remaining neurons) is the effect of stimulation parameters, such as the interphase gap (IPG), on the amplitude growth function (AGF) of the electrically evoked compound action potential (ECAP). The extent to which such measures reflect neural factors, rather than non-neural factors (e.g. electrode orientation, electrode-modiolus distance, and impedance), depends crucially upon how the AGF data are analysed. However, there is currently no consensus in the literature for the correct method to interpret changes in the ECAP AGF due to changes in stimulation parameters. We present a simple theoretical model for the effect of IPG on ECAP AGFs, along with a re-analysis of both animal and human data that measured the IPG effect. Both the theoretical model and the re-analysis of the animal data suggest that the IPG effect on ECAP AGF slope (IPG slope effect), measured using either a linear or logarithmic input-output scale, does not successfully control for the effects of non-neural factors. Both the model and the data suggest that the appropriate method to estimate neural health is by measuring the IPG offset effect, defined as the dB offset between the linear portions of ECAP AGFs for two stimuli differing only in IPG.
Collapse
Affiliation(s)
- Tim Brochier
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK.
| | - Colette M McKay
- Bionics Institute, 384-388 Albert Street, East Melbourne, VIC, 3002, Australia
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
50
|
Konerding W, Arenberg JG, Kral A, Baumhoff P. Late electrically-evoked compound action potentials as markers for acute micro-lesions of spiral ganglion neurons. Hear Res 2020; 413:108057. [PMID: 32883545 DOI: 10.1016/j.heares.2020.108057] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 07/13/2020] [Accepted: 08/11/2020] [Indexed: 12/20/2022]
Abstract
Cochlear implants (CIs) are the treatment of choice for profoundly hearing impaired people. It has been proposed that speech perception in CI users is influenced by the neural health (deafferentation, demyelination and degeneration) of the cochlea, which may be heterogeneous along an individual cochlea. Several options have been put forward to account for these local differences in neural health when fitting the speech processor settings, however with mixed results. The interpretation of the results is hampered by the fact that reliable markers of locally restricted changes in spiral ganglion neuron (SGN) health are lacking. The aim of the study was (i) to establish mechanical micro-lesions in the guinea pig as a model of heterogeneous SGN deafferentation and degeneration and (ii) to assess potential electrophysiological markers that can also be used in human subjects. First, we defined the extent of micro-lesions in normal hearing animals using acoustically-evoked compound action potentials (aCAPs); second, we measured electrically-evoked CAPs (eCAPs) before and after focal lesioning in neomycin-deafened and implanted animals. Therefore, we inserted guinea pig adjusted 6-contact CIs through a cochleostomy in the scala tympani. The eCAP was recorded from a ball electrode at the round window niche in response to monopolar or bipolar, 50 µs/phase biphasic pulses of alternating anodic- and cathodic-leading polarity. To exclude the large electrical artifact from the analysis, we focused on the late eCAP component. We systematically isolated the eCAP parameter that showed local pre- versus post-lesion changes and lesion-target specificity. Histological evaluation of the cleared cochleae revealed focal damage of an average size of 0.0036 mm3 with an apical-basal span of maximal 440 µm. We found that the threshold of the late N2P2 eCAP component was significantly elevated after lesioning when stimulating at basal (near the lesion), but not apical (distant to the lesion) CI contacts. To circumvent the potentially conflicting influence of the apical-basal gradient in eCAP thresholds, we used the polarity effect (PE=cathodic-anodic) as a relative measure. During monopolar stimulation, but not bipolar stimulation, the PE was sensitive to the lesion target and showed significantly better cathodic than anodic thresholds after soma lesions. We conclude that the difference in N2P2 thresholds in response to cathodic versus anodic-leading monopolar stimulation corresponds to the presence of SGN soma damage, and may therefore be a marker for SGN loss. We consider this electrophysiological estimate of local neural health a potentially relevant tool for human applications because of the temporal separation from the stimulation artifact and possible implementation into common eCAP measurements.
Collapse
Affiliation(s)
- Wiebke Konerding
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany.
| | - Julie G Arenberg
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA.
| | - Andrej Kral
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany; Cluster of Excellence "Hearing4all", Germany.
| | - Peter Baumhoff
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany.
| |
Collapse
|