1
|
Camarena A, Goldsworthy RL. Characterizing the relationship between modulation sensitivity and pitch resolution in cochlear implant users. Hear Res 2024; 448:109026. [PMID: 38776706 DOI: 10.1016/j.heares.2024.109026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 03/28/2024] [Accepted: 04/30/2024] [Indexed: 05/25/2024]
Abstract
Cochlear implants are medical devices that have restored hearing to approximately one million people around the world. Outcomes are impressive and most recipients attain excellent speech comprehension in quiet without relying on lip-reading cues, but pitch resolution is poor compared to normal hearing. Amplitude modulation of electrical stimulation is a primary cue for pitch perception in cochlear implant users. The experiments described in this article focus on the relationship between sensitivity to amplitude modulations and pitch resolution based on changes in the frequency of amplitude modulations. In the first experiment, modulation sensitivity and pitch resolution were measured in adults with no known hearing loss and in cochlear implant users with sounds presented to and processed by their clinical devices. Stimuli were amplitude-modulated sinusoids and amplitude-modulated narrow-band noises. Modulation detection and modulation frequency discrimination were measured for modulation frequencies centered on 110, 220, and 440 Hz. Pitch resolution based on changes in modulation frequency was measured for modulation depths of 25 %, 50 %, 100 %, and for a half-waved rectified modulator. Results revealed a strong linear relationship between modulation sensitivity and pitch resolution for cochlear implant users and peers with no known hearing loss. In the second experiment, cochlear implant users took part in analogous procedures of modulation sensitivity and pitch resolution but bypassing clinical sound processing using single-electrode stimulation. Results indicated that modulation sensitivity and pitch resolution was better conveyed by single-electrode stimulation than by clinical processors. Results at 440 Hz were worse, but also not well conveyed by clinical sound processing, so it remains unclear whether the 300 Hz perceptual limit described in the literature is a technological or biological limitation. These results highlight modulation depth and sensitivity as critical factors for pitch resolution in cochlear implant users and characterize the relationship that should inform the design of modulation enhancement algorithms for cochlear implants.
Collapse
Affiliation(s)
- Andres Camarena
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
| | - Raymond L Goldsworthy
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America.
| |
Collapse
|
2
|
Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models. Hear Res 2022; 426:108643. [PMID: 36343534 PMCID: PMC9986845 DOI: 10.1016/j.heares.2022.108643] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/29/2022] [Accepted: 10/20/2022] [Indexed: 11/04/2022]
Abstract
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural structures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomical/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is generally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from animal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.
Collapse
|
3
|
He S, Skidmore J, Carter BL, Lemeshow S, Sun S. Postlingually Deafened Adult Cochlear Implant Users With Prolonged Recovery From Neural Adaptation at the Level of the Auditory Nerve Tend to Have Poorer Speech Perception Performance. Ear Hear 2022; 43:1761-1770. [PMID: 35652833 PMCID: PMC9588496 DOI: 10.1097/aud.0000000000001244] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE This study investigated the effects of two temporal response properties of the auditory nerve (i.e., neural adaptation and recovery from neural adaptation) on speech perception performance in postlingually deafened adult cochlear implant (CI) users. DESIGN Study participants included 18 postlingually deafened adults who were Cochlear Nucleus device users with a full electrode array insertion in the test ear(s). Neural adaptation and adaptation recovery of the auditory nerve (AN) were evaluated using electrophysiological measures of the electrically evoked compound action potential (eCAP). The amount of neural adaptation was quantified by the adaptation index within three time windows: 0 to 8.89 (window 1), 44.44 to 50.00 (window 2), and 94.44 to 100.00 ms (window 3). The speed of neural adaptation was estimated using a two-parameter power law function. To evaluate adaptation recovery of the AN, eCAPs to the last pulse of the 100-ms pulse train were recorded at masker-probe-intervals ranging from 1.054 to 256 ms in logarithmic steps. The amount of adaptation recovery was quantified by the adaptation recovery ratio. The time-constant of adaptation recovery was estimated using an exponential function with up to three components. Speech perception performance was evaluated by measuring consonant-nucleus-consonant (CNC) word scores presented in quiet and in speech-shaped noise at a signal-to-noise ratio (SNR) of +10 dB. One-tailed Pearson Product Moment correlation tests were used (1) to assess the associations among parameters of neural adaptation and adaptation recovery and (2) to evaluate the strength of association between these parameters and CNC word scores measured in quiet and in noise. The contributions of different parameters quantifying neural adaptation and adaptation recovery on speech perception scores were evaluated using multivariable linear regression analyses. RESULTS The Pearson Product Moment correlation coefficient demonstrated a moderate, negative correlation between the speed of adaptation recovery and CNC word scores measured in quiet and in noise. The speed of adaptation recovery accounted for 14.1% of variability in CNC word scores measured in quiet and 16.7% of variability in CNC word scores measured in noise. The correlation strengths between CNC word scores and the adaptation index, the adaptation recovery ratio and the speed of neural adaptation ranged from negligible to weak. CONCLUSIONS The speed of adaptation recovery plays a more important role than other features of neural adaptation and adaptation recovery of the AN in speech perception in postlingually deafened adult CI users. Patients with prolonged adaptation recovery tend to show poorer speech perception performance.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, College of Medicine, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, College of Medicine, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Brittney L. Carter
- Department of Otolaryngology – Head and Neck Surgery, College of Medicine, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Stanley Lemeshow
- Division of Biostatistics, College of Public Health, The Ohio State University, 1841 Neil Avenue, Columbus, OH 43210
| | - Shuai Sun
- Division of Biostatistics, College of Public Health, The Ohio State University, 1841 Neil Avenue, Columbus, OH 43210
| |
Collapse
|
4
|
Clinard CG, Lawlor KJ, Thorne AP, Piker EG. Nonlinearity in bone-conducted amplitude-modulated cervical vestibular evoked myogenic potentials: Harmonic distortion products. J Neurophysiol 2022; 127:791-800. [PMID: 35171737 DOI: 10.1152/jn.00347.2021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Otolith organs of the balance system, the saccule and utricle, encode linear acceleration. Integrity of the saccule is commonly assessed using cervical vestibular evoked myogenic potentials (cVEMPs) arising from an inhibitory reflex along the vestibulospinal pathway. Conventional approaches to eliciting these responses use brief, transient sounds to elicit onset responses. Here we used long-duration amplitude-modulated (AM) tones to elicit cVEMPs (AMcVEMPs) and analyzed their spectral content for evidence of nonlinear processing consistent with known characteristics of vestibular hair cells. Twelve young adults (ages 21-25) with no hearing or vestibular pathologies participated in this study. AMcVEMPs were elicited by bone-conducted AM tones with a 500 Hz carrier frequency. Eighteen modulation frequencies were used between 7 and 403 Hz. All participants had robust distortion products at harmonics of the modulation frequency. Total harmonic distortion ranged from approximately 10 to 80%. AMcVEMPs contain harmonic distortion products consistent with vestibular hair cell nonlinearities, and this new approach to studying the otolith organs may provide a non-invasive, in vivo method to study nonlinearity of vestibular hair cells in humans.
Collapse
Affiliation(s)
- Christopher G Clinard
- Communication Sciences and Disorders, James Madison University, Harrisonburg, VA, United States
| | - Kerri J Lawlor
- Communication Sciences and Disorders, James Madison University, Harrisonburg, VA, United States
| | - Andrew P Thorne
- Communication Sciences and Disorders, James Madison University, Harrisonburg, VA, United States
| | - Erin G Piker
- Communication Sciences and Disorders, James Madison University, Harrisonburg, VA, United States
| |
Collapse
|
5
|
Characteristics of the Adaptation Recovery Function of the Auditory Nerve and Its Association With Advanced Age in Postlingually Deafened Adult Cochlear Implant Users. Ear Hear 2022; 43:1472-1486. [PMID: 35139051 PMCID: PMC9325924 DOI: 10.1097/aud.0000000000001198] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE This study aimed to (1) characterize the amount and the speed of recovery from neural adaptation at the auditory nerve (AN) and (2) assess their associations with advanced age in postlingually deafened adult cochlear implant users. DESIGN Study participants included 25 postlingually deafened adult, Cochlear Nucleus device users, ranging in age between 24.83 and 83.21 years at the time of testing. The stimulus was a 100-ms pulse train presented at four pulse rates: 500, 900, 1800, and 2400 pulses per second (pps). The pulse trains were presented at the maximum comfortable level measured for the 2400-pps pulse train. The electrically evoked compound action potential (eCAP) evoked by the last pulse of the pulse train (i.e., the probe pulse) was recorded. The remaining pulses of the pulse train served as the pulse-train masker. The time interval between the probe pulse and the last pulse of the pulse-train masker [i.e., masker-probe-interval (MPI)] systematically increased from 0.359 ms up to 256 ms. The adaptation recovery function (ARF) was obtained by plotting normalized eCAP amplitudes (re: the eCAP amplitude measured at the MPI of 256 ms) as a function of MPIs. The adaptation recovery ratio (ARR) was defined as the ratio between the eCAP amplitude measured at the MPI of 256 ms and that measured for the single-pulse stimulus presented at the same stimulation level. The time constants of the ARF were estimated using a mathematical model with an exponential function with up to three components. Generalized Linear Mixed effects Models were used to compare ARRs and time constants measured at different electrode locations and pulse rates, as well as to assess the effect of advanced age on these dependent variables. RESULTS There were three ARF types observed in this study. The ARF type observed in the same study participant could be different at different electrode locations and/or pulse rates. Substantial variations in both the amount and the speed of neural adaptation recovery among study participants were observed. The ARR was significantly affected by pulse rate but was not affected by electrode location. The effect of electrode location on the time constants of the ARF was not statistically significant. Pulse rate had a statistically significant effect on τ 1, but not on τ 2 or τ 3 . There was no statistically significant effect of age on the ARR or the time constants of the ARF. CONCLUSIONS Neural adaptation recovery processes at the AN demonstrate substantial variations among human cochlear implant users. The recovery pattern can be nonmonotonic with up to three phases. While the amount of neural adaptation recovery decreases as pulse rate increases, only the speed of the first phase of neural adaptation recovery is affected by pulse rate. Electrode location or advanced age has no robust effect on neural adaptation recovery processes at the level of the AN for a 100-ms pulse-train masker with pulse rates of 500 to 2400 pps. The lack of sufficient participants in this study who were 40 years of age or younger at the time of testing might have precluded a thorough assessment of the effect of advanced age.
Collapse
|
6
|
Phenomenological model of auditory nerve population responses to cochlear implant stimulation. J Neurosci Methods 2021; 358:109212. [PMID: 33957156 DOI: 10.1016/j.jneumeth.2021.109212] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 04/26/2021] [Accepted: 04/29/2021] [Indexed: 01/19/2023]
Abstract
BACKGROUND Models of auditory nerve fiber (ANF) responses to electrical stimulation are helpful to develop advanced coding for cochlear implants (CIs). A phenomenological model of ANF population responses to CI electrical stimulation with a lower computational complexity compared to a biophysical model would be beneficial to evaluate new CI coding strategies. NEW METHOD This study presents a phenomenological model which combines four temporal characteristics of ANFs (refractoriness, facilitation, accommodation and spike rate adaptation) in addition to a spatial spread of the electric field. RESULTS The model predicts the performances of CI subjects in the melodic contour identification (MCI) experiment. The simulations for the MCI experiment were consistent with CI recipients' experimental outcomes that were not predictable from the electrical stimulation patterns themselves. COMPARISON WITH EXISTING METHODS Previously, no phenomenological population model of ANFs has combined all four aforementioned temporal phenomena. CONCLUSIONS The proposed model would help the further investigations of ANFs responses to different electrical stimulation patterns and comparison of different sound coding strategies in CIs.
Collapse
|
7
|
The Sensitivity of the Electrically Stimulated Auditory Nerve to Amplitude Modulation Cues Declines With Advanced Age. Ear Hear 2021; 42:1358-1372. [PMID: 33795616 DOI: 10.1097/aud.0000000000001035] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study aimed to investigate effects of aging and duration of deafness on sensitivity of the auditory nerve (AN) to amplitude modulation (AM) cues delivered using trains of biphasic pulses in adult cochlear implant (CI) users. DESIGN There were 21 postlingually deaf adult CI users who participated in this study. All study participants used a Cochlear Nucleus device with a full electrode array insertion in the test ear. The stimulus was a 200-ms pulse train with a pulse rate of 2000 pulses per second. This carrier pulse train was sinusodially AM at four modulation rates (20, 40, 100, 200 Hz). The peak amplitude of the modulated pulse train was the maximum comfortable level (i.e., C level) measured for the carrier pulse train. The electrically evoked compound action potential (eCAP) to each of the 20 pulses selected over the last two AM cycles were measured. In addition, eCAPs to single pulses were measured with the probe levels corresponding to the levels of 20 selected pulses from each AM pulse train. There were seven electrodes across the array evaluated in 16 subjects (i.e., electrodes 3 or 4, 6, 9, 12, 15, 18, and 21). For the remaining five subjects, 4 to 5 electrodes were tested due to impedance issues or time constraints. The modulated response amplitude ratio (MRAR) was calculated as the ratio of the difference in the maximum and the minimum eCAP amplitude measured for the AM pulse train to that measured for the single pulse, and served as the dependent variable. Age at time of testing and duration of deafness measured/defined using three criteria served as the independent variables. Linear Mixed Models were used to assess the effects of age at testing and duration of deafness on the MRAR. RESULTS Age at testing had a strong, negative effect on the MRAR. For each subject, the duration of deafness varied substantially depending on how it was defined/measured, which demonstrates the difficulty of accurately measuring the duration of deafness in adult CI users. There was no clear or reliable trend showing a relationship between the MRAR measured at any AM rate and duration of deafness defined by any criteria. After controlling for the effect of age at testing, MRARs measured at 200 Hz and basal electrode locations (i.e., electrodes 3 and 6) were larger than those measured at any other AM rate and apical electrode locations (i.e., electrodes 18 and 21). CONCLUSIONS The AN sensitivity to AM cues implemented in the pulse-train stimulation significantly declines with advanced age. Accurately measuring duration of deafness in adult CI users is challenging, which, at least partially, might have accounted for the inconclusive findings in the relationship between the duration of deafness and the AN sensitivity to AM cues in this study.
Collapse
|
8
|
van Gendt MJ, Briaire JJ, Frijns JHM. Effect of neural adaptation and degeneration on pulse-train ECAPs: A model study. Hear Res 2019; 377:167-178. [PMID: 30947041 DOI: 10.1016/j.heares.2019.03.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 01/13/2019] [Accepted: 03/13/2019] [Indexed: 01/17/2023]
Abstract
Electrically evoked compound action potentials (eCAPs) are measurements of the auditory nerve's response to electrical stimulation. ECAP amplitudes during pulse trains can exhibit temporal alternations. The magnitude of this alternation tends to diminish over time during the stimulus. How this pattern relates to the temporal behavior of nerve fibers is not known. We hypothesized that the stochasticity, refractoriness, adaptation of the threshold and spike-times influence pulse-train eCAP responses. Thirty thousand auditory nerve fibers were modeled in a three-dimensional cochlear model incorporating pulse-shape effects, pulse-history effects, and stochasticity in the individual neural responses. ECAPs in response to pulse trains of different rates and amplitudes were modeled for fibers with different stochastic properties (by variation of the relative spread) and different temporal properties (by variation of the refractory periods, adaptation and latency). The model predicts alternation of peak amplitudes similar to available human data. In addition, the peak alternation was affected by changing the refractoriness, adaptation, and relative spread of auditory nerve fibers. As these parameters are related to factors such as the duration of deafness and neural survival, this study suggests that the eCAP pattern in response to pulse trains could be used to assess the underlying temporal and stochastic behavior of the auditory nerve. As these properties affect the nerve's response to pulse trains, they are of uttermost importance to sound perception with cochlear implants.
Collapse
Affiliation(s)
- M J van Gendt
- ENT-Department, Leiden University Medical Centre, PO Box 9600, 2300, RC Leiden, the Netherlands.
| | - J J Briaire
- ENT-Department, Leiden University Medical Centre, PO Box 9600, 2300, RC Leiden, the Netherlands
| | - J H M Frijns
- ENT-Department, Leiden University Medical Centre, PO Box 9600, 2300, RC Leiden, the Netherlands; Leiden Institute for Brain and Cognition, PO Box 9600, 2300, RC Leiden, the Netherlands
| |
Collapse
|
9
|
Relationship Between Peripheral and Psychophysical Measures of Amplitude Modulation Detection in Cochlear Implant Users. Ear Hear 2018; 38:e268-e284. [PMID: 28207576 DOI: 10.1097/aud.0000000000000417] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE This study investigates the relationship between electrophysiological and psychophysical measures of amplitude modulation (AM) detection. Prior studies have reported both measures of AM detection recorded separately from cochlear implant (CI) users and acutely deafened animals, but no study has made both measures in the same CI users. Animal studies suggest a progressive loss of high-frequency encoding as one ascends the auditory pathway from the auditory nerve to the cortex. Because the CI speech processor uses the envelope of an ongoing acoustic signal to modulate pulse trains that are subsequently delivered to the intracochlear electrodes, it is of interest to explore auditory nerve responses to modulated stimuli. In addition, psychophysical AM detection abilities have been correlated with speech perception outcomes. Thus, the goal was to explore how the auditory nerve responds to AM stimuli and to relate those physiologic measures to perception. DESIGN Eight patients using Cochlear Ltd. Implants participated in this study. Electrically evoked compound action potentials (ECAPs) were recorded using a 4000 pps pulse train that was sinusoidally amplitude modulated at 125, 250, 500, and 1000 Hz rates. Responses were measured for each pulse over at least one modulation cycle for an apical, medial, and basal electrode. Psychophysical modulation detection thresholds (MDTs) were also measured via a three-alternative forced choice, two-down, one-up adaptive procedure using the same modulation frequencies and electrodes. RESULTS ECAPs were recorded from individual pulses in the AM pulse train. ECAP amplitudes varied sinusoidally, reflecting the sinusoidal variation in the stimulus. A modulated response amplitude (MRA) metric was calculated as the difference in the maximal and minimum ECAP amplitudes over the modulation cycles. MRA increased as modulation frequency increased, with no apparent cutoff (up to 1000 Hz). In contrast, MDTs increased as the modulation frequency increased. This trend is inconsistent with the physiologic measures. For a fixed modulation frequency, correlations were observed between MDTs and MRAs; this trend was evident at all frequencies except 1000 Hz (although only statistically significant for 250 and 500 Hz AM rates), possibly an indication of central limitations in processing of high modulation frequencies. Finally, peripheral responses were larger and psychophysical thresholds were lower in the apical electrodes relative to basal and medial electrodes, which may reflect better cochlear health and neural survival evidenced by lower preoperative low-frequency audiometric thresholds and steeper growth of neural responses in ECAP amplitude growth functions for apical electrodes. CONCLUSIONS Robust ECAPs were recorded for all modulation frequencies tested. ECAP amplitudes varied sinusoidally, reflecting the periodicity of the modulated stimuli. MRAs increased as the modulation frequency increased, a trend we attribute to neural adaptation. For low modulation frequencies, there are multiple current steps between the peak and valley of the modulation cycle, which means successive stimuli are more similar to one another and neural responses are more likely to adapt. Higher MRAs were correlated with lower psychophysical thresholds at low modulation frequencies but not at 1000 Hz, implying a central limitation to processing of modulated stimuli.
Collapse
|
10
|
The Relationship Between Intensity Coding and Binaural Sensitivity in Adults With Cochlear Implants. Ear Hear 2018; 38:e128-e141. [PMID: 27787393 DOI: 10.1097/aud.0000000000000382] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Many bilateral cochlear implant users show sensitivity to binaural information when stimulation is provided using a pair of synchronized electrodes. However, there is large variability in binaural sensitivity between and within participants across stimulation sites in the cochlea. It was hypothesized that within-participant variability in binaural sensitivity is in part affected by limitations and characteristics of the auditory periphery which may be reflected by monaural hearing performance. The objective of this study was to examine the relationship between monaural and binaural hearing performance within participants with bilateral cochlear implants. DESIGN Binaural measures included dichotic signal detection and interaural time difference discrimination thresholds. Diotic signal detection thresholds were also measured. Monaural measures included dynamic range and amplitude modulation detection. In addition, loudness growth was compared between ears. Measures were made at three stimulation sites per listener. RESULTS Greater binaural sensitivity was found with larger dynamic ranges. Poorer interaural time difference discrimination was found with larger difference between comfortable levels of the two ears. In addition, poorer diotic signal detection thresholds were found with larger differences between the dynamic ranges of the two ears. No relationship was found between amplitude modulation detection thresholds or symmetry of loudness growth and the binaural measures. CONCLUSIONS The results suggest that some of the variability in binaural hearing performance within listeners across stimulation sites can be explained by factors nonspecific to binaural processing. The results are consistent with the idea that dynamic range and comfortable levels relate to peripheral neural survival and the width of the excitation pattern which could affect the fidelity with which central binaural nuclei process bilateral inputs.
Collapse
|
11
|
He S, Teagle HFB, Buchman CA. The Electrically Evoked Compound Action Potential: From Laboratory to Clinic. Front Neurosci 2017; 11:339. [PMID: 28690494 PMCID: PMC5481377 DOI: 10.3389/fnins.2017.00339] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Accepted: 05/30/2017] [Indexed: 11/13/2022] Open
Abstract
The electrically evoked compound action potential (eCAP) represents the synchronous firing of a population of electrically stimulated auditory nerve fibers. It can be directly recorded on a surgically exposed nerve trunk in animals or from an intra-cochlear electrode of a cochlear implant. In the past two decades, the eCAP has been widely recorded in both animals and clinical patient populations using different testing paradigms. This paper provides an overview of recording methodologies and response characteristics of the eCAP, as well as its potential applications in research and clinical situations. Relevant studies are reviewed and implications for clinicians are discussed.
Collapse
Affiliation(s)
- Shuman He
- Center for Hearing Research, Boys Town National Research HospitalOmaha, NE, United States
| | - Holly F. B. Teagle
- Department of Otolaryngology—Head and Neck Surgery, University of North Carolina at Chapel HillChapel Hill, NC, United States
| | - Craig A. Buchman
- Department of Otolaryngology—Head and Neck Surgery, Washington UniversitySt. Louis, MO, United States
| |
Collapse
|