1
|
Dolhopiatenko H, Segovia-Martinez M, Nogueira W. The temporal mismatch across listening sides affects cortical auditory evoked responses in normal hearing listeners and cochlear implant users with contralateral acoustic hearing. Hear Res 2024; 451:109088. [PMID: 39032483 DOI: 10.1016/j.heares.2024.109088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 06/10/2024] [Accepted: 07/16/2024] [Indexed: 07/23/2024]
Abstract
Combining a cochlear implant with contralateral acoustic hearing typically enhances speech understanding, although this improvement varies among CI users and can lead to an interference effect. This variability may be associated with the effectiveness of the integration between electric and acoustic stimulation, which might be affected by the temporal mismatch between the two listening sides. Finding methods to compensate for the temporal mismatch might contribute to the optimal adjustment of bimodal devices and to improve hearing in CI users with contralateral acoustic hearing. The current study investigates cortical auditory evoked potentials (CAEPs) in normal hearing listeners (NH) and CI users with contralateral acoustic hearing. In NH, the amplitude of the N1 peak and the maximum phase locking value (PLV) were analyzed under monaural, binaural, and binaural temporally mismatched conditions. In CI users, CAEPs were measured when listening with CI only (CIS_only), acoustically only (AS_only) and with both sides together (CIS+AS). When listening with CIS+AS, various interaural delays were introduced between the electric and acoustic stimuli. In NH listeners, interaural temporal mismatch resulted in decreased N1 amplitude and PLV. Moreover, PLV is suggested as a more sensitive measure to investigate the integration of information between the two listening sides. CI users showed varied N1 latencies between the AS_only and CIS_only listening conditions, with increased N1 amplitude when the temporal mismatch was compensated. A tendency towards increased PLV was also observed, however, to a lesser extent than in NH listeners, suggesting a limited integration between electric and acoustic stimulation. This work highlights the potential of CAEPs measurement to investigate cortical processing of the information between two listening sides in NH and bimodal CI users.
Collapse
Affiliation(s)
- Hanna Dolhopiatenko
- Medical University Hannover, Cluster of Excellence 'Hearing4all', Hannover, Germany
| | | | - Waldo Nogueira
- Medical University Hannover, Cluster of Excellence 'Hearing4all', Hannover, Germany.
| |
Collapse
|
2
|
Bernstein JGW, Voelker J, Phatak SA. Headphones over the cochlear-implant sound processor to replace direct audio input. JASA EXPRESS LETTERS 2024; 4:094406. [PMID: 39315944 DOI: 10.1121/10.0028737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Accepted: 08/26/2024] [Indexed: 09/25/2024]
Abstract
Psychoacoustic stimulus presentation to the cochlear implant via direct audio input (DAI) is no longer possible for many newer sound processors (SPs). This study assessed the feasibility of placing circumaural headphones over the SP. Calibration spectra for loudspeaker, DAI, and headphone modalities were estimated by measuring cochlear-implant electrical output levels for tones presented to SPs on an acoustic manikin. Differences in calibration spectra between modalities arose mainly from microphone-response characteristics (high-frequency differences between DAI and the other modalities) or a proximity effect (low-frequency differences between headphones and loudspeaker). Calibration tables are provided to adjust for differences between the three modalities.
Collapse
Affiliation(s)
- Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, , ,
| | - Julianna Voelker
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, , ,
| | - Sandeep A Phatak
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, , ,
| |
Collapse
|
3
|
Borjigin A, Kokkinakis K, Bharadwaj HM, Stohl JS. Deep learning restores speech intelligibility in multi-talker interference for cochlear implant users. Sci Rep 2024; 14:13241. [PMID: 38853168 PMCID: PMC11163011 DOI: 10.1038/s41598-024-63675-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 05/31/2024] [Indexed: 06/11/2024] Open
Abstract
Cochlear implants (CIs) do not offer the same level of effectiveness in noisy environments as in quiet settings. Current single-microphone noise reduction algorithms in hearing aids and CIs only remove predictable, stationary noise, and are ineffective against realistic, non-stationary noise such as multi-talker interference. Recent developments in deep neural network (DNN) algorithms have achieved noteworthy performance in speech enhancement and separation, especially in removing speech noise. However, more work is needed to investigate the potential of DNN algorithms in removing speech noise when tested with listeners fitted with CIs. Here, we implemented two DNN algorithms that are well suited for applications in speech audio processing: (1) recurrent neural network (RNN) and (2) SepFormer. The algorithms were trained with a customized dataset ( ∼ 30 h), and then tested with thirteen CI listeners. Both RNN and SepFormer algorithms significantly improved CI listener's speech intelligibility in noise without compromising the perceived quality of speech overall. These algorithms not only increased the intelligibility in stationary non-speech noise, but also introduced a substantial improvement in non-stationary noise, where conventional signal processing strategies fall short with little benefits. These results show the promise of using DNN algorithms as a solution for listening challenges in multi-talker noise interference.
Collapse
Affiliation(s)
- Agudemu Borjigin
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, 47907, IN, USA.
- Waisman Center, University of Wisconsin-Madison, Madison, WI, 53705, USA.
- North American Research Laboratory, MED-EL Corporation, Durham, NC, 27713, USA.
| | - Kostas Kokkinakis
- Concha Labs, San Francisco, CA, 94114, USA
- North American Research Laboratory, MED-EL Corporation, Durham, NC, 27713, USA
| | - Hari M Bharadwaj
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, 47907, IN, USA
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, 47907, IN, USA
- Department of Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA, 15213, USA
| | - Joshua S Stohl
- North American Research Laboratory, MED-EL Corporation, Durham, NC, 27713, USA
| |
Collapse
|
4
|
Rader T, Schrank L, Spiegel JL, Nachtigäller P, Spiro JE, Hempel JM, Canis M, Mueller J. Comparison of speech perception in bimodal cochlear implant patients with respect to the cochlear coverage. HNO 2024; 72:17-24. [PMID: 37608133 PMCID: PMC10799137 DOI: 10.1007/s00106-023-01327-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/13/2023] [Indexed: 08/24/2023]
Abstract
BACKGROUND The hearing success of patients with bimodal fitting, utilizing both a cochlear implant (CI) and a hearing aid (HA), varies considerably: While some patients benefit from bimodal CI and HA, others do not. OBJECTIVES This retrospective study aimed to investigate speech perception in bimodally fitted patients and compare it with the cochlear coverage (CC). METHODS The CC was calculated with the OTOPLAN software, measuring the cochlear duct length on temporal bone CT scans of 39 patients retrospectively. The patients were categorized into two groups: CC ≤ 65% (CC500) and CC > 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65 dB in a free-field setting was assessed before and after CI at various time points. The two groups, one with preoperative HA and one with postoperative CI, were compared. Additionally, speech intelligibility was correlated with CC in the entire cohort before CI and at the last available follow-up (last observation time, LOT). RESULTS Overall, there was no significant difference in speech intelligibility between CC500 and CC600 patients, with both groups demonstrating a consistent improvement after implantation. While CC600 patients tended to exhibit earlier improvement in speech intelligibility, CC500 patients showed a slower initial improvement within the first 3 months but demonstrated a steeper learning curve thereafter. At LOT, the two patient groups converged, with no significant differences in expected speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. Interestingly, patients with a CC of 70-75% achieved the highest speech intelligibility. CONCLUSION Despite of the lack of a significant correlation between CC and speech perception, patients appeared to reach their maximum in unimodal/unilateral speech perception primarily at a coverage level of 70-75%. Nevertheless, further investigation is warranted, as CC500 was associated with shorter cochlear duct length, and different types of electrodes were used in both groups.
Collapse
Affiliation(s)
- Tobias Rader
- Division of Audiology, Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Leonhard Schrank
- Division of Audiology, Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Jennifer L Spiegel
- Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Munich, Germany
- German Center for Vertigo and Balance Disorders, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Pascal Nachtigäller
- Division of Audiology, Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Judith E Spiro
- Department for Radiology, LMU University Hospital, LMU Munich, Munich, Germany
| | - John-Martin Hempel
- Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Martin Canis
- Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Joachim Mueller
- Department of Otorhinolaryngology, LMU University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
5
|
Körtje M, Stöver T, Baumann U, Weissgerber T. Impact of processing-latency induced interaural delay and level discrepancy on sensitivity to interaural level differences in cochlear implant users. Eur Arch Otorhinolaryngol 2023; 280:5241-5249. [PMID: 37219685 PMCID: PMC10620283 DOI: 10.1007/s00405-023-08013-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 05/08/2023] [Indexed: 05/24/2023]
Abstract
PURPOSE This study investigated whether an interaural delay, e.g. caused by the processing latency of a hearing device, can affect sensitivity to interaural level differences (ILDs) in normal hearing subjects or cochlear implant (CI) users with contralateral normal hearing (SSD-CI). METHODS Sensitivity to ILD was measured in 10 SSD-CI subjects and in 24 normal hearing subjects. The stimulus was a noise burst presented via headphones and via a direct cable connection (CI). ILD sensitivity was measured for different interaural delays in the range induced by hearing devices. ILD sensitivity was correlated with results obtained in a sound localization task using seven loudspeakers in the frontal horizontal plane. RESULTS In the normal hearing subjects the sensitivity to interaural level differences deteriorated significantly with increasing interaural delays. In the CI group, no significant effect of interaural delays on ILD sensitivity was found. The NH subjects were significantly more sensitive to ILDs. The mean localization error in the CI group was 10.8° higher than in the normal hearing group. No correlation between sound localization ability and ILD sensitivity was found. CONCLUSION Interaural delays influence the perception of ILDs. For normal hearing subjects a significant decrement in sensitivity to ILD was measured. The effect could not be confirmed in the tested SSD-CI group, probably due to a small subject group with large variations. The temporal matching of the two sides may be beneficial for ILD processing and thus sound localization for CI patients. However, further studies are needed for verification.
Collapse
Affiliation(s)
- Monika Körtje
- ENT Department, Audiological Acoustics, Goethe University Frankfurt, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt (Main), Germany.
| | - Timo Stöver
- ENT Department, Goethe University Frankfurt, University Hospital Frankfurt, Frankfurt (Main), Germany
| | - Uwe Baumann
- ENT Department, Audiological Acoustics, Goethe University Frankfurt, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt (Main), Germany
| | - Tobias Weissgerber
- ENT Department, Audiological Acoustics, Goethe University Frankfurt, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt (Main), Germany
| |
Collapse
|
6
|
Andren KG, Duffin K, Ryan MT, Riley CA, Tolisano AM. Postoperative optimization of cochlear implantation for single sided deafness and asymmetric hearing loss: a systematic review. Cochlear Implants Int 2023; 24:342-353. [PMID: 37490782 DOI: 10.1080/14670100.2023.2239512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2023]
Abstract
OBJECTIVE Identify and evaluate the effectiveness of methods for improving postoperative cochlear implant (CI) hearing performance in subjects with single-sided deafness (SSD) and asymmetric hearing loss (AHL). DATA SOURCES Embase, PubMed, Scopus. REVIEW METHODS Systematic review and narrative synthesis. English language studies of adult CI recipients with SSD and AHL reporting a postoperative intervention and comparative audiometric data pertaining to speech in noise, speech in quiet and sound localization were included. RESULTS 32 studies met criteria for full text review and 6 (n = 81) met final inclusion criteria. Interventions were categorized as: formal auditory training, programming techniques, or hardware optimization. Formal auditory training (n = 10) found no objective improvement in hearing outcomes. Experimental CI maps did not improve audiologic outcomes (n = 9). Programed CI signal delays to improve synchronization demonstrated improved sound localization (n = 12). Hardware optimization, including multidirectional (n = 29) and remote (n = 11) microphones, improved sound localization and speech in noise, respectively. CONCLUSION Few studies meeting inclusion criteria and small sample sizes highlight the need for further study. Formal auditory training did not appear to improve hearing outcomes. Programming techniques, such as CI signal delay, and hardware optimization, such as multidirectional and remote microphones, show promise to improve outcomes for SSD and AHL CI users.
Collapse
Affiliation(s)
- Kristofer G Andren
- Department of Otolaryngology - Head & Neck Surgery, San Antonio Uniformed Services Health Education Consortium, San Antonio, TX, USA
| | - Kevin Duffin
- Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Matthew T Ryan
- Department of Otolaryngology - Head & Neck Surgery, Walter Reed National Military Medical Center, Bethesda, MD, USA
| | - Charles A Riley
- Department of Otolaryngology - Head & Neck Surgery, Walter Reed National Military Medical Center, Bethesda, MD, USA
- Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Anthony M Tolisano
- Department of Otolaryngology - Head & Neck Surgery, Walter Reed National Military Medical Center, Bethesda, MD, USA
- Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| |
Collapse
|
7
|
Rader T, Schrank L, Spiegel JL, Nachtigäller P, Spiro JE, Hempel JM, Canis M, Müller J. [Speech perception as a function of cochlear coverage-comparison in bimodally hearing cochlear implant patients. German version]. HNO 2023:10.1007/s00106-023-01330-w. [PMID: 37450020 PMCID: PMC10403407 DOI: 10.1007/s00106-023-01330-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/13/2023] [Indexed: 07/18/2023]
Abstract
BACKGROUND Hearing success in bimodally hearing patients with a cochlear implant (CI) and a hearing aid (HA) exhibits different results: while some benefit from bimodal CI and HA, others do not. OBJECTIVE The aim of this study was to investigate hearing success in terms of speech perception in bimodally fitted patients in relation to the cochlear coverage (CC) of the CI electrodes. MATERIALS AND METHODS Using the OTOPLAN software (CAScination AG, Bern, Switzerland), CC was retrospectively measured from CT scans of the temporal bone of 39 patients, who were then categorized into two groups: CC ≤ 65% (CC500) and CC > 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65 dB in open field was assessed at various timepoints, preoperatively with HA and postoperatively with CI, and compared between the groups. In addition, speech intelligibility was correlated with CC in the entire cohort before surgery and during follow-up (FU). RESULTS Overall, no significant differences in speech intelligibility were found between CC500 and CC600 patients at any of the FU timepoints. However, both CC500 and CC600 patients showed a steady improvement in speech intelligibility after implantation. While CC600 patients tended to show an earlier improvement in speech intelligibility, CC500 patients tended to show a slower improvement during the first 3 months and a steeper learning curve thereafter. The two patient groups converged during FU, with no significant differences in speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. However, patients with a CC of 70-75% achieved maximum speech intelligibility. CONCLUSION Despite a nonsignificant correlation between CC and speech discrimination, patients seem to reach their maximum in unimodal/unilateral speech understanding mainly at 70-75% coverage. However, there is room for further investigation, as CC500 was associated with a shorter cochlear duct length (CDL), and long and very long electrodes were used in both groups.
Collapse
Affiliation(s)
- Tobias Rader
- Abteilung Audiologie, Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, Marchioninistr. 15, 81377, München, Deutschland.
| | - Leonhard Schrank
- Abteilung Audiologie, Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - Jennifer L Spiegel
- Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, München, Deutschland
- Deutsches Schwindel- und Gleichgewichtszentrum, LMU Klinikum der Universität München, München, Deutschland
| | - Pascal Nachtigäller
- Abteilung Audiologie, Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - Judith E Spiro
- Klinik und Poliklinik für Radiologie, LMU Klinikum der Universität München, München, Deutschland
| | - John-Martin Hempel
- Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, München, Deutschland
| | - Martin Canis
- Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, München, Deutschland
| | - Joachim Müller
- Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, LMU Klinikum der Universität München, München, Deutschland
| |
Collapse
|
8
|
Zirn S, Hemmert W, Roth S, Müller FU, Angermeier J. [Interaural stimulation timing mismatch in listeners provided with a cochlear implant and a hearing aid : A review focusing on quantification and compensation]. HNO 2023:10.1007/s00106-023-01308-8. [PMID: 37219567 DOI: 10.1007/s00106-023-01308-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/11/2023] [Indexed: 05/24/2023]
Abstract
Bimodal provision of patients with asymmetric hearing loss with a hearing aid ipsilaterally and a cochlear implant (CI) contralaterally is probably the most complicated type of CI provision due to a variety of inherent variables. This review article presents all the systematic interaural mismatches between electric and acoustic stimulation that can occur in bimodal listeners. One of these mismatches is the interaural latency offset, i.e., the time difference of activation of the auditory nerve by acoustic and electric stimulation. Methods for quantifying this offset are presented by registering electrically and acoustically evoked potentials and measuring processing delays in the devices. Technical compensation of the interaural latency offset and its positive effect on sound localization ability in bimodal listeners is also described. Finally, most recent findings are discussed which may explain why compensation of the interaural latency offset does not improve speech understanding in noise in bimodal listeners.
Collapse
Affiliation(s)
- Stefan Zirn
- Fakultät Elektrotechnik, Medizintechnik und Informatik, Peter-Osypka-Institut für Medizintechnik (POIM), Hochschule Offenburg, Badstr. 24, 77652, Offenburg, Deutschland.
| | - Werner Hemmert
- Bioinspirierte Informationsverarbeitung, Fakultät Elektrotechnik und Informationstechnik, Technische Universität München, München, Deutschland
| | - Sebastian Roth
- Fakultät Elektrotechnik, Medizintechnik und Informatik, Peter-Osypka-Institut für Medizintechnik (POIM), Hochschule Offenburg, Badstr. 24, 77652, Offenburg, Deutschland
- Bioinspirierte Informationsverarbeitung, Fakultät Elektrotechnik und Informationstechnik, Technische Universität München, München, Deutschland
| | - Franz-Ullrich Müller
- Fakultät Elektrotechnik, Medizintechnik und Informatik, Peter-Osypka-Institut für Medizintechnik (POIM), Hochschule Offenburg, Badstr. 24, 77652, Offenburg, Deutschland
| | - Julian Angermeier
- Fakultät Elektrotechnik, Medizintechnik und Informatik, Peter-Osypka-Institut für Medizintechnik (POIM), Hochschule Offenburg, Badstr. 24, 77652, Offenburg, Deutschland
| |
Collapse
|
9
|
Karoui C, Strelnikov K, Payoux P, Salabert AS, James CJ, Deguine O, Barone P, Marx M. Auditory cortical plasticity after cochlear implantation in asymmetric hearing loss is related to spatial hearing: a PET H215O study. Cereb Cortex 2023; 33:2229-2244. [PMID: 35640270 PMCID: PMC9977387 DOI: 10.1093/cercor/bhac204] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 04/28/2022] [Accepted: 04/29/2022] [Indexed: 01/20/2023] Open
Abstract
In asymmetric hearing loss (AHL), the normal pattern of contralateral hemispheric dominance for monaural stimulation is modified, with a shift towards the hemisphere ipsilateral to the better ear. The extent of this shift has been shown to relate to sound localization deficits. In this study, we examined whether cochlear implantation to treat postlingual AHL can restore the normal functional pattern of auditory cortical activity and whether this relates to improved sound localization. The auditory cortical activity was found to be lower in the AHL cochlear implanted (AHL-CI) participants. A cortical asymmetry index was calculated and showed that a normal contralateral dominance was restored in the AHL-CI patients for the nonimplanted ear, but not for the ear with the cochlear implant. It was found that the contralateral dominance for the nonimplanted ear strongly correlated with sound localization performance (rho = 0.8, P < 0.05). We conclude that the reorganization of binaural mechanisms in AHL-CI subjects reverses the abnormal lateralization pattern induced by the deafness, and that this leads to improved spatial hearing. Our results suggest that cochlear implantation enables the reconstruction of the cortical mechanisms of spatial selectivity needed for sound localization.
Collapse
Affiliation(s)
- Chadlia Karoui
- UMR 5549, Faculté de Médecine Purpan, Centre National de la Recherche Scientifique, Toulouse, France.,Centre de Recherche Cerveau et Cognition, Université de Toulouse, Université Paul Sabatier, Toulouse, France
| | - Kuzma Strelnikov
- UMR 5549, Faculté de Médecine Purpan, Centre National de la Recherche Scientifique, Toulouse, France.,Centre de Recherche Cerveau et Cognition, Université de Toulouse, Université Paul Sabatier, Toulouse, France
| | - Pierre Payoux
- Nuclear Medicine Department, Purpan University Hospital, Toulouse, France.,ToNIC, Toulouse NeuroImaging Center, Université de Toulouse, Inserm, UPS, Toulouse, France
| | - Anne-Sophie Salabert
- Nuclear Medicine Department, Purpan University Hospital, Toulouse, France.,ToNIC, Toulouse NeuroImaging Center, Université de Toulouse, Inserm, UPS, Toulouse, France
| | - Chris J James
- Cochlear France SAS, Toulouse, France.,Service d'Oto-Rhino-Laryngologie et Oto-Neurologie, CHU Toulouse France, Université Toulouse 3, Toulouse, France
| | - Olivier Deguine
- UMR 5549, Faculté de Médecine Purpan, Centre National de la Recherche Scientifique, Toulouse, France.,Centre de Recherche Cerveau et Cognition, Université de Toulouse, Université Paul Sabatier, Toulouse, France.,Service d'Oto-Rhino-Laryngologie et Oto-Neurologie, CHU Toulouse France, Université Toulouse 3, Toulouse, France
| | - Pascal Barone
- UMR 5549, Faculté de Médecine Purpan, Centre National de la Recherche Scientifique, Toulouse, France.,Centre de Recherche Cerveau et Cognition, Université de Toulouse, Université Paul Sabatier, Toulouse, France
| | - Mathieu Marx
- UMR 5549, Faculté de Médecine Purpan, Centre National de la Recherche Scientifique, Toulouse, France.,Centre de Recherche Cerveau et Cognition, Université de Toulouse, Université Paul Sabatier, Toulouse, France.,Service d'Oto-Rhino-Laryngologie et Oto-Neurologie, CHU Toulouse France, Université Toulouse 3, Toulouse, France
| |
Collapse
|
10
|
Dolhopiatenko H, Nogueira W. Selective attention decoding in bimodal cochlear implant users. Front Neurosci 2023; 16:1057605. [PMID: 36711138 PMCID: PMC9874229 DOI: 10.3389/fnins.2022.1057605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 12/20/2022] [Indexed: 01/12/2023] Open
Abstract
The growing group of cochlear implant (CI) users includes subjects with preserved acoustic hearing on the opposite side to the CI. The use of both listening sides results in improved speech perception in comparison to listening with one side alone. However, large variability in the measured benefit is observed. It is possible that this variability is associated with the integration of speech across electric and acoustic stimulation modalities. However, there is a lack of established methods to assess speech integration between electric and acoustic stimulation and consequently to adequately program the devices. Moreover, existing methods do not provide information about the underlying physiological mechanisms of this integration or are based on simple stimuli that are difficult to relate to speech integration. Electroencephalography (EEG) to continuous speech is promising as an objective measure of speech perception, however, its application in CIs is challenging because it is influenced by the electrical artifact introduced by these devices. For this reason, the main goal of this work is to investigate a possible electrophysiological measure of speech integration between electric and acoustic stimulation in bimodal CI users. For this purpose, a selective attention decoding paradigm has been designed and validated in bimodal CI users. The current study included behavioral and electrophysiological measures. The behavioral measure consisted of a speech understanding test, where subjects repeated words to a target speaker in the presence of a competing voice listening with the CI side (CIS) only, with the acoustic side (AS) only or with both listening sides (CIS+AS). Electrophysiological measures included cortical auditory evoked potentials (CAEPs) and selective attention decoding through EEG. CAEPs were recorded to broadband stimuli to confirm the feasibility to record cortical responses with CIS only, AS only, and CIS+AS listening modes. In the selective attention decoding paradigm a co-located target and a competing speech stream were presented to the subjects using the three listening modes (CIS only, AS only, and CIS+AS). The main hypothesis of the current study is that selective attention can be decoded in CI users despite the presence of CI electrical artifact. If selective attention decoding improves combining electric and acoustic stimulation with respect to electric stimulation alone, the hypothesis can be confirmed. No significant difference in behavioral speech understanding performance when listening with CIS+AS and AS only was found, mainly due to the ceiling effect observed with these two listening modes. The main finding of the current study is the possibility to decode selective attention in CI users even if continuous artifact is present. Moreover, an amplitude reduction of the forward transfer response function (TRF) of selective attention decoding was observed when listening with CIS+AS compared to AS only. Further studies to validate selective attention decoding as an electrophysiological measure of electric acoustic speech integration are required.
Collapse
|
11
|
A Study of Event-Related Potentials During Monaural and Bilateral Hearing in Single-Sided Deaf Cochlear Implant Users. Ear Hear 2023:00003446-990000000-00102. [PMID: 36706105 DOI: 10.1097/aud.0000000000001326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVES Single-sided deafness (SSD) is characterized by a profoundly deaf ear and normal hearing in the contralateral ear. A cochlear implant (CI) is the only method to restore functional hearing in a profoundly deaf ear. In a previous study, we identified that the cortical processing of a CI signal differs from the normal-hearing ear (NHE) when directly compared using an auditory oddball paradigm consisting of pure tones. However, exactly how the brain integrates the electrical and acoustic signal is not well investigated. This study aims to understand how the provision of the CI in combination with the NHE may improve SSD CI users' ability to discriminate and evaluate auditory stimuli. DESIGN Electroencephalography from 10 SSD-CI participants (4 participated in the previous pure-tone study) were recorded during a semantic acoustic oddball task, where they were required to discriminate between odd and even numbers. Stimuli were presented in four hearing conditions: directly through the CI, directly to the NHE, or in free field with the CI switched on and off. We examined task-performance (response time and accuracy) and measured N1, P2, N2N4, and P3b event-related brain potentials (ERPs) linked to the detection, discrimination, and evaluation of task relevant stimuli. Sound localization and speech in noise comprehension was also examined. RESULTS In direct presentation, task performance was superior during NHE compared with CI (shorter and less varied reaction times [~720 versus ~842 msec], higher target accuracy [~93 versus ~70%]) and early neural responses (N1 and P2) were enhanced for NHE suggesting greater signal saliency. However, the size of N2N4 and P3b target-standard effects did not differ significantly between NHE and CI. In free field, target accuracy was similarly high with the CI (FF-On) and without the CI (FF-Off) (~95%), with some evidence of CI interference during FF-On (more variable and slightly but significantly delayed reaction times [~737 versus ~709 msec]). Early neural responses and late effects were also greater during FF-On. Performance on sound localization and speech in noise comprehension (S CI N NHE configuration only) was significantly greater during FF-On. CONCLUSIONS Both behavioral and neural responses in the semantic oddball task were sensitive to CI in both direct and free-field presentations. Direct conditions revealed that participants could perform the task with the CI alone, although performance was suboptimal and early neural responses were reduced when compared with the NHE. For free-field, the addition of the CI was associated with enhanced early and late neural responses, but this did not result in improved task performance. Enhanced neural responses show that the additional input from the CI is modulating relevant perceptual and cognitive processes, but the benefit of binaural hearing on behavior may not be realized in simple oddball tasks which can be adequately performed with the NHE. Future studies interested in binaural hearing should examine performance under noisy conditions and/or use spatial cues to allow headroom for the measurement of binaural benefit.
Collapse
|
12
|
Seebacher J, Franke-Trieger A, Weichbold V, Galvan O, Schmutzhard J, Zorowka P, Stephan K. Sound localisation of low- and high-frequency sounds in cochlear implant users with single-sided deafness. Int J Audiol 2023; 62:71-78. [PMID: 35103553 DOI: 10.1080/14992027.2022.2030496] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Localisation of low- and high-frequency sounds in single-sided deaf cochlear implant users was investigated using noise stimuli designed to mitigate monaural localisation cues. DESIGN Within subject design. Sound source localisation was tested in the horizontal plane using an array of seven loudspeakers along the azimuthal angle span from -90° to +90°. Stimuli were broadband noise and high- and low-frequency noise. STUDY SAMPLE Twelve adult subjects with single-sided deafness participated in the study. All had normal hearing in the healthy ear and were supplied with a cochlear implant (CI) in their deaf ear. RESULTS With broadband noise, the mean angular localisation error was 39° in aided condition as compared to a median angular error of 83.6° when the speech processor was not worn. For high-frequency noise, the median angular error was 30° and for low-frequency noise, it was 46° in the CI-aided condition. CONCLUSIONS Single-sided deaf CI users show the best sound localisation for high-frequency sounds. This supports the view that interaural level differences are dominant for sound localisation in these listeners. Nonetheless, a limited ability to localise low-frequency sounds was observed, which may be based on the supportive perception of interaural time differences.
Collapse
Affiliation(s)
- J Seebacher
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria
| | - A Franke-Trieger
- Saxonian Cochlear Implant Center, Department of Otorhinolaryngology, Technical University of Dresden, Dresden, Germany
| | - V Weichbold
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria
| | - O Galvan
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria
| | - J Schmutzhard
- Department of Otorhinolaryngology, Medical University Innsbruck, Innsbruck, Austria
| | - P Zorowka
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria
| | - K Stephan
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria
| |
Collapse
|
13
|
Jürgens T, Wesarg T, Oetting D, Jung L, Williges B. Spatial speech-in-noise performance in simulated single-sided deaf and bimodal cochlear implant users in comparison with real patients. Int J Audiol 2023; 62:30-43. [PMID: 34962428 DOI: 10.1080/14992027.2021.2015633] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 11/30/2021] [Accepted: 12/03/2021] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Speech reception thresholds (SRTs) in spatial scenarios were measured in simulated cochlear implant (CI) listeners with either contralateral normal hearing, or aided hearing impairment (bimodal), and compared to SRTs of real patients, who were measured using the exact same paradigm, to assess goodness of simulation. DESIGN CI listening was simulated using a vocoder incorporating actual CI signal processing and physiologic details of electric stimulation on one side. Unprocessed signals or simulation of aided moderate or profound hearing impairment was used contralaterally. Three spatial speech-in-noise scenarios were tested using virtual acoustics to assess spatial release from masking (SRM) and combined benefit. STUDY SAMPLE Eleven normal-hearing listeners participated in the experiment. RESULTS For contralateral normal and aided moderately impaired hearing, bilaterally assessed SRTs were not statistically different from unilateral SRTs of the better ear, indicating "better-ear-listening". Combined benefit was only found for contralateral profound impaired hearing. As in patients, SRM was highest for contralateral normal hearing and decreased systematically with more severe simulated impairment. Comparison to actual patients showed good reproduction of SRTs, SRM, and better-ear-listening. CONCLUSIONS The simulations reproduced better-ear-listening as in patients and suggest that combined benefit in spatial scenes predominantly occurs when both ears show poor speech-in-noise performance.
Collapse
Affiliation(s)
- Tim Jürgens
- Institute of Acoustics, University of Applied Sciences Lübeck, Lübeck, Germany
- Medical Physics and Cluster of Excellence "Hearing4all", Carl-von-Ossietzky University, Oldenburg, Germany
| | - Thomas Wesarg
- Faculty of Medicine, Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, University of Freiburg, Freiburg, Germany
| | | | - Lorenz Jung
- Faculty of Medicine, Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, University of Freiburg, Freiburg, Germany
| | - Ben Williges
- Medical Physics and Cluster of Excellence "Hearing4all", Carl-von-Ossietzky University, Oldenburg, Germany
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
| |
Collapse
|
14
|
American Cochlear Implant Alliance Task Force Guidelines for Clinical Assessment and Management of Adult Cochlear Implantation for Single-Sided Deafness. Ear Hear 2022; 43:1605-1619. [PMID: 35994570 PMCID: PMC9592177 DOI: 10.1097/aud.0000000000001260] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The indications for cochlear implantation have expanded to include individuals with profound sensorineural hearing loss in the impaired ear and normal hearing (NH) in the contralateral ear, known as single-sided deafness (SSD). There are additional considerations for the clinical assessment and management of adult cochlear implant candidates and recipients with SSD as compared to conventional cochlear implant candidates with bilateral moderate to profound sensorineural hearing loss. The present report reviews the current evidence relevant to the assessment and management of adults with SSD. A systematic review was also conducted on published studies that investigated outcomes of cochlear implant use on measures of speech recognition in quiet and noise, sound source localization, tinnitus perception, and quality of life for this patient population. Expert consensus and systematic review of the current literature were combined to provide guidance for the clinical assessment and management of adults with SSD.
Collapse
|
15
|
Longitudinal auditory data of children with prelingual single-sided deafness managed with early cochlear implantation. Sci Rep 2022; 12:9376. [PMID: 35672363 PMCID: PMC9174487 DOI: 10.1038/s41598-022-13247-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Accepted: 05/23/2022] [Indexed: 11/09/2022] Open
Abstract
Individuals with single-sided deafness (SSD) have no access to binaural hearing, which limits their ability to localize sounds and understand speech in noisy environments. In addition, children with prelingual SSD are at risk for neurocognitive and academic difficulties. Early cochlear implantation may lead to improved hearing outcomes by restoring bilateral hearing. However, its longitudinal impact on the development of children with SSD remains unclear. In the current study, a group of young children with prelingual SSD received a cochlear implant at an early age. From the age of four, the children’s spatial hearing skills could be assessed using a spatial speech perception in noise test and a sound localization test. The results are compared to those of two control groups: children with SSD without a cochlear implant and children with bilateral normal hearing. Overall, the implanted group exhibited improved speech perception in noise abilities and better sound localization skills, compared to their non-implanted peers. On average, the children wore their device approximately nine hours a day. Given the large contribution of maturation to the development of spatial hearing skills, further follow-up is important to understand the long-term benefit of a cochlear implant for children with prelingual SSD.
Collapse
|
16
|
Dirks CE, Nelson PB, Oxenham AJ. No Benefit of Deriving Cochlear-Implant Maps From Binaural Temporal-Envelope Sensitivity for Speech Perception or Spatial Hearing Under Single-Sided Deafness. Ear Hear 2022; 43:310-322. [PMID: 34291758 PMCID: PMC8770730 DOI: 10.1097/aud.0000000000001094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES This study tested whether speech perception and spatial acuity improved in people with single-sided deafness and a cochlear implant (SSD+CI) when the frequency allocation table (FAT) of the CI was adjusted to optimize frequency-dependent sensitivity to binaural disparities. DESIGN Nine SSD+CI listeners with at least 6 months of CI listening experience participated. Individual experimental FATs were created to best match the frequency-to-place mapping across ears using either sensitivity to binaural temporal-envelope disparities or estimated insertion depth. Spatial localization ability was measured, along with speech perception in spatially collocated or separated noise, first with the clinical FATs and then with the experimental FATs acutely and at 2-month intervals for 6 months. Listeners then returned to the clinical FATs and were retested acutely and after 1 month to control for long-term learning effects. RESULTS The experimental FAT varied between listeners, differing by an average of 0.15 octaves from the clinical FAT. No significant differences in performance were observed in any of the measures between the experimental FAT after 6 months and the clinical FAT one month later, and no clear relationship was found between the size of the frequency-allocation shift and perceptual changes. CONCLUSION Adjusting the FAT to optimize sensitivity to interaural temporal-envelope disparities did not improve localization or speech perception. The clinical frequency-to-place alignment may already be sufficient, given the inherently poor spectral resolution of CIs. Alternatively, other factors, such as temporal misalignment between the two ears, may need to be addressed before any benefits of spectral alignment can be observed.
Collapse
Affiliation(s)
- Coral E Dirks
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota, USA
- Center for Applied and Translational Sensory Sciences, Department of Psychology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Peggy B Nelson
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota, USA
- Center for Applied and Translational Sensory Sciences, Department of Psychology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Andrew J Oxenham
- Center for Applied and Translational Sensory Sciences, Department of Psychology, University of Minnesota, Minneapolis, Minnesota, USA
- Department of Psychology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
17
|
Polak M, Lorens A, Walkowiak A, Furmanek M, Skarzynski PH, Skarzynski H. In Vivo Basilar Membrane Time Delays in Humans. Brain Sci 2022; 12:400. [PMID: 35326357 PMCID: PMC8946056 DOI: 10.3390/brainsci12030400] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 03/11/2022] [Accepted: 03/11/2022] [Indexed: 12/10/2022] Open
Abstract
To date, objective measurements and psychophysical experiments have been used to measure frequency dependent basilar membrane (BM) delays in humans; however, in vivo measurements have not been made. This study aimed to measure BM delays by performing intracochlear electrocochleography in cochlear implant recipients. Sixteen subjects with various degrees of hearing abilities were selected. Postoperative Computer Tomography was performed to determine electrode locations. Electrical potentials in response to acoustic tone pips at 0.25, 0.5, 1, 2, and 4 kHz and clicks were recorded with electrodes at the frequency specific region. The electrode array was inserted up to the characteristic cochlear frequency region of 250 Hz for 6 subjects. Furthermore, the array was inserted in the region of 500 Hz for 15 subjects, and 1, 2, and 4 kHz were reached in all subjects. Intracochlear electrocochleography for each frequency-specific tone pip and clicks showed detectable responses in all subjects. The latencies differed among the cochlear location and the cochlear microphonic (CM) onset latency increased with decreasing frequency and were consistent with click derived band technique. Accordingly, BM delays in humans could be derived. The BM delays increased systematically along the cochlea from basal to apical end and were in accordance with Ruggero and Temchin, 2007.
Collapse
Affiliation(s)
- Marek Polak
- R&D Med-El, Furstenweg 77A, 6020 Innsbruck, Austria
| | - Artur Lorens
- Institute of Physiology and Pathology of Hearing, 02-042 Warsaw, Poland; (A.L.); (A.W.); (M.F.); (P.H.S.); (H.S.)
| | - Adam Walkowiak
- Institute of Physiology and Pathology of Hearing, 02-042 Warsaw, Poland; (A.L.); (A.W.); (M.F.); (P.H.S.); (H.S.)
| | - Mariusz Furmanek
- Institute of Physiology and Pathology of Hearing, 02-042 Warsaw, Poland; (A.L.); (A.W.); (M.F.); (P.H.S.); (H.S.)
| | - Piotr Henryk Skarzynski
- Institute of Physiology and Pathology of Hearing, 02-042 Warsaw, Poland; (A.L.); (A.W.); (M.F.); (P.H.S.); (H.S.)
| | - Henryk Skarzynski
- Institute of Physiology and Pathology of Hearing, 02-042 Warsaw, Poland; (A.L.); (A.W.); (M.F.); (P.H.S.); (H.S.)
| |
Collapse
|
18
|
Saadoun A, Schein A, Péan V, Legrand P, Aho Glélé LS, Bozorg Grayeli A. Frequency Fitting Optimization Using Evolutionary Algorithm in Cochlear Implant Users with Bimodal Binaural Hearing. Brain Sci 2022; 12:brainsci12020253. [PMID: 35204015 PMCID: PMC8870060 DOI: 10.3390/brainsci12020253] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 01/26/2022] [Accepted: 01/28/2022] [Indexed: 02/04/2023] Open
Abstract
Optimizing hearing in patients with a unilateral cochlear implant (CI) and contralateral acoustic hearing is a challenge. Evolutionary algorithms (EA) can explore a large set of potential solutions in a stochastic manner to approach the optimum of a minimization problem. The objective of this study was to develop and evaluate an EA-based protocol to modify the default frequency settings of a MAP (fMAP) of the CI in patients with bimodal hearing. Methods: This monocentric prospective study included 27 adult CI users (with post-lingual deafness and contralateral functional hearing). A fitting program based on EA was developed to approach the best fMAP. Generated fMAPs were tested by speech recognition (word recognition score, WRS) in noise and free-field-like conditions. By combining these first fMAPs and adding some random changes, a total of 13 fMAPs over 3 generations were produced. Participants were evaluated before and 45 to 60 days after the fitting by WRS in noise and questionnaires on global sound quality and music perception in bimodal binaural conditions. Results: WRS in noise improved with the EA-based fitting in comparison to the default fMAP (41.67 ± 9.70% versus 64.63 ± 16.34%, respectively, p = 0.0001, signed-rank test). The global sound quality and music perception were also improved, as judged by ratings on questionnaires and scales. Finally, most patients chose to keep the new fitting definitively. Conclusions: By modifying the default fMAPs, the EA improved the speech discrimination in noise and the sound quality in bimodal binaural conditions.
Collapse
Affiliation(s)
- Alexis Saadoun
- Department of Otolaryngology—Head and Neck Surgery, Dijon University Hospital, 21000 Dijon, France; (A.S.); (A.S.)
| | - Antoine Schein
- Department of Otolaryngology—Head and Neck Surgery, Dijon University Hospital, 21000 Dijon, France; (A.S.); (A.S.)
| | - Vincent Péan
- Clinical Support Department, MED-EL, 75012 Paris, France;
| | - Pierrick Legrand
- Institute of Mathematics of Bordeaux, UMR CNRS 5251, ASTRAL Team, Inria Bordeaux Sud-Ouest, University of Bordeaux, 33405 Talence, France;
| | - Ludwig Serge Aho Glélé
- Department of Hospital Epidemiology and Infection Control, Dijon University Hospital, 21000 Dijon, France;
| | - Alexis Bozorg Grayeli
- Department of Otolaryngology—Head and Neck Surgery, Dijon University Hospital, 21000 Dijon, France; (A.S.); (A.S.)
- ImVia Research Laboratory, Bourgogne-Franche Comté University, 21000 Dijon, France
- Correspondence:
| |
Collapse
|
19
|
Angermeier J, Hemmert W, Zirn S. Measuring and Modeling Cue Dependent Spatial Release from Masking in the Presence of Typical Delays in the Treatment of Hearing Loss. Trends Hear 2022; 26:23312165221094202. [PMID: 35473484 PMCID: PMC9052821 DOI: 10.1177/23312165221094202] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In asymmetric treatment of hearing loss, processing latencies of the modalities typically
differ. This often alters the reference interaural time difference (ITD) (i.e., the ITD at
0° azimuth) by several milliseconds. Such changes in reference ITD have shown to influence
sound source localization in bimodal listeners provided with a hearing aid (HA) in one and
a cochlear implant (CI) in the contralateral ear. In this study, the effect of changes in
reference ITD on speech understanding, especially spatial release from masking (SRM) in
normal-hearing subjects was explored. Speech reception thresholds (SRT) were measured in
ten normal-hearing subjects for reference ITDs of 0, 1.75, 3.5, 5.25 and 7 ms with
spatially collocated (S0N0) and spatially separated
(S0N90) sound sources. Further, the cues for separation of target
and masker were manipulated to measure the effect of a reference ITD on unmasking by A)
ITDs and interaural level differences (ILDs), B) ITDs only and C) ILDs only. A blind
equalization-cancellation (EC) model was applied to simulate all measured conditions. SRM
decreased significantly in conditions A) and B) when the reference ITD was increased: In
condition A) from 8.8 dB SNR on average at 0 ms reference ITD to 4.6 dB at 7 ms, in
condition B) from 5.5 dB to 1.1 dB. In condition C) no significant effect was found. These
results were accurately predicted by the applied EC-model. The outcomes show that
interaural processing latency differences should be considered in asymmetric treatment of
hearing loss.
Collapse
Affiliation(s)
- Julian Angermeier
- Peter Osypka Institute of Medical Engineering, Faculty of Electrical Engineering, Medical Engineering and Computer Sciences, 64369University of Applied Sciences Offenburg.,Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, 9184Technical University of Munich
| | - Werner Hemmert
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, 9184Technical University of Munich
| | - Stefan Zirn
- Peter Osypka Institute of Medical Engineering, Faculty of Electrical Engineering, Medical Engineering and Computer Sciences, 64369University of Applied Sciences Offenburg
| |
Collapse
|
20
|
Pieper SH, Hamze N, Brill S, Hochmuth S, Exter M, Polak M, Radeloff A, Buschermöhle M, Dietz M. Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf. Trends Hear 2022; 26:23312165221108259. [PMID: 35726211 PMCID: PMC9218456 DOI: 10.1177/23312165221108259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 04/28/2022] [Accepted: 05/02/2022] [Indexed: 11/16/2022] Open
Abstract
When listening with a cochlear implant through one ear and acoustically through the other, binaural benefits and spatial hearing abilities are generally poorer than in other bilaterally stimulated configurations. With the working hypothesis that binaural neurons require interaurally matched inputs, we review causes for mismatch, their perceptual consequences, and experimental methods for mismatch measurements. The focus is on the three primary interaural dimensions of latency, frequency, and level. Often, the mismatch is not constant, but rather highly stimulus-dependent. We report on mismatch compensation strategies, taking into consideration the specific needs of the respective patient groups. Practical challenges typically faced by audiologists in the proposed fitting procedure are discussed. While improvement in certain areas (e.g., speaker localization) is definitely achievable, a more comprehensive mismatch compensation is a very ambitious endeavor. Even in the hypothetical ideal fitting case, performance is not expected to exceed that of a good bilateral cochlear implant user.
Collapse
Affiliation(s)
- Sabrina H. Pieper
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
| | - Noura Hamze
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Stefan Brill
- MED-EL Medical Electronics Germany GmbH, Starnberg, Germany
| | - Sabine Hochmuth
- Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany
| | - Mats Exter
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
- Hörzentrum Oldenburg gGmbH, Oldenburg, Germany
| | - Marek Polak
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Andreas Radeloff
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
- Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany
- Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| | | | - Mathias Dietz
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
- Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
21
|
Sharma S, Nogueira W, van Opstal AJ, Chalupper J, Mens LHM, van Wanrooij MM. Amount of Frequency Compression in Bimodal Cochlear Implant Users Is a Poor Predictor for Audibility and Spatial Hearing. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2021; 64:5000-5013. [PMID: 34714704 DOI: 10.1044/2021_jslhr-20-00653] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
PURPOSE Speech understanding in noise and horizontal sound localization is poor in most cochlear implant (CI) users with a hearing aid (bimodal stimulation). This study investigated the effect of static and less-extreme adaptive frequency compression in hearing aids on spatial hearing. By means of frequency compression, we aimed to restore high-frequency audibility, and thus improve sound localization and spatial speech recognition. METHOD Sound-detection thresholds, sound localization, and spatial speech recognition were measured in eight bimodal CI users, with and without frequency compression. We tested two compression algorithms: a static algorithm, which compressed frequencies beyond the compression knee point (160 or 480 Hz), and an adaptive algorithm, which aimed to compress only consonants leaving vowels unaffected (adaptive knee-point frequencies from 736 to 2946 Hz). RESULTS Compression yielded a strong audibility benefit (high-frequency thresholds improved by 40 and 24 dB for static and adaptive compression, respectively), no meaningful improvement in localization performance (errors remained > 30 deg), and spatial speech recognition across all participants. Localization biases without compression (toward the hearing-aid and implant side for low- and high-frequency sounds, respectively) disappeared or reversed with compression. The audibility benefits provided to each bimodal user partially explained any individual improvements in localization performance; shifts in bias; and, for six out of eight participants, benefits in spatial speech recognition. CONCLUSIONS We speculate that limiting factors such as a persistent hearing asymmetry and mismatch in spectral overlap prevent compression in bimodal users from improving sound localization. Therefore, the benefit in spatial release from masking by compression is likely due to a shift of attention to the ear with the better signal-to-noise ratio facilitated by compression, rather than an improved spatial selectivity. Supplemental Material https://doi.org/10.23641/asha.16869485.
Collapse
Affiliation(s)
- Snandan Sharma
- Department of Biophysics, Donders Institute for Brain, Cognition and Behaviour, Radboud University, Nijmegen, the Netherlands
| | - Waldo Nogueira
- Department of Otolaryngology, Cluster of Excellence Hearing4all, Medical University Hannover, Germany
| | - A John van Opstal
- Department of Biophysics, Donders Institute for Brain, Cognition and Behaviour, Radboud University, Nijmegen, the Netherlands
| | - Josef Chalupper
- Advanced Bionics, European Research Center, Hannover, Germany
| | - Lucas H M Mens
- Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Marc M van Wanrooij
- Department of Biophysics, Donders Institute for Brain, Cognition and Behaviour, Radboud University, Nijmegen, the Netherlands
| |
Collapse
|
22
|
Bernstein JGW, Jensen KK, Stakhovskaya OA, Noble JH, Hoa M, Kim HJ, Shih R, Kolberg E, Cleary M, Goupell MJ. Interaural Place-of-Stimulation Mismatch Estimates Using CT Scans and Binaural Perception, But Not Pitch, Are Consistent in Cochlear-Implant Users. J Neurosci 2021; 41:10161-10178. [PMID: 34725189 PMCID: PMC8660045 DOI: 10.1523/jneurosci.0359-21.2021] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 08/23/2021] [Accepted: 10/01/2021] [Indexed: 11/21/2022] Open
Abstract
Bilateral cochlear implants (BI-CIs) or a CI for single-sided deafness (SSD-CI; one normally functioning acoustic ear) can partially restore spatial-hearing abilities, including sound localization and speech understanding in noise. For these populations, however, interaural place-of-stimulation mismatch can occur and thus diminish binaural sensitivity that relies on interaurally frequency-matched neurons. This study examined whether plasticity-reorganization of central neural pathways over time-can compensate for peripheral interaural place mismatch. We hypothesized differential plasticity across two systems: none for binaural processing but adaptation for pitch perception toward frequencies delivered by the specific electrodes. Interaural place mismatch was evaluated in 19 BI-CI and 23 SSD-CI human subjects (both sexes) using binaural processing (interaural-time-difference discrimination with simultaneous bilateral stimulation), pitch perception (pitch ranking for single electrodes or acoustic tones with sequential bilateral stimulation), and physical electrode-location estimates from computed-tomography (CT) scans. On average, CT scans revealed relatively little BI-CI interaural place mismatch (26° insertion-angle mismatch) but a relatively large SSD-CI mismatch, particularly at low frequencies (166° for an electrode tuned to 300 Hz, decreasing to 14° at 7000 Hz). For BI-CI subjects, the three metrics were in agreement because there was little mismatch. For SSD-CI subjects, binaural and CT measurements were in agreement, suggesting little binaural-system plasticity induced by mismatch. The pitch measurements disagreed with binaural and CT measurements, suggesting place-pitch plasticity or a procedural bias. These results suggest that reducing interaural place mismatch and potentially improving binaural processing by reprogramming the CI frequency allocation would be better done using CT-scan than pitch information.SIGNIFICANCE STATEMENT Electrode-array placement for cochlear implants (bionic prostheses that partially restore hearing) does not explicitly align neural representations of frequency information. The resulting interaural place-of-stimulation mismatch can diminish spatial-hearing abilities. In this study, adults with two cochlear implants showed reasonable interaural alignment, whereas those with one cochlear implant but normal hearing in the other ear often showed mismatch. In cases of mismatch, binaural sensitivity was best when the same cochlear locations were stimulated in both ears, suggesting that binaural brainstem pathways do not experience plasticity to compensate for mismatch. In contrast, interaurally pitch-matched electrodes deviated from cochlear-location estimates and did not optimize binaural sensitivity. Clinical correction of interaural place mismatch using binaural or computed-tomography (but not pitch) information may improve spatial-hearing benefits.
Collapse
Affiliation(s)
- Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Kenneth K Jensen
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Olga A Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee 37232
| | - Michael Hoa
- Department of Otolaryngology Head and Neck Surgery, Georgetown University Medical Center, Washington, DC 20057
| | - H Jeffery Kim
- Department of Otolaryngology Head and Neck Surgery, Georgetown University Medical Center, Washington, DC 20057
| | - Robert Shih
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Elizabeth Kolberg
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| |
Collapse
|
23
|
Abstract
OBJECTIVES The primary goal of the study was to investigate electrical cortical auditory evoked potentials (eCAEPs) at maximum comfortable level (MCL) and 50% MCL on three cochlear implant (CI) electrodes and compare them with the acoustic CAEP (aCAEPs), in terms of the amplitude and latency of the P1-N1-P2 complex. This was achieved by comparing the eCAEP obtained with the method described and stimulating single electrodes, via the fitting software spanning the cochlear array and the aCAEP obtained using the HEARLab system at four speech tokens. DESIGN Twenty MED-EL (MED-EL Medical Electronics, Innsbruck, Austria) CI adult users were tested. CAEP recording with HEARLab System was performed with speech tokens /m/, /g/, /t/, and /s/ in free field, presented at 55 dB SPL. eCAEPs were recorded with an Evoked Potential device triggered from the MAX Programming Interface (MED-EL Medical Devices) with 70 msec electrical burst at 0.9 Hz at the apical (1), middle (6), and basal (10 or 11) CI electrode at their MCL and 50% MCL. RESULTS CAEP responses were recorded in 100% of the test subjects for the speech token /t/, 95% for the speech tokens /g/ and /s/, and 90% for the speech token /m/. For eCAEP recordings, in all subjects, it was possible to identify N1 and P2 peaks when stimulating the apical and middle electrodes. This incidence of detection decreased to an 85% chance of stimulation at 50% MCL on the same electrodes. A P1 peak was less evident for all electrodes. There was an overall increase in latency for stimulation at 50% MCL compared with MCL. There was a significant difference in the amplitude of adjacent peaks (P1-N1 and N1-P2) for 50% MCL compared with MCL. The mean of the maximum cross-correlation values were in the range of 0.63 to 0.68 for the four speech tokens. The distribution of the calculated time shift, where the maximum of the cross-correlation was found, was distributed between the speech tokens. The speech token /g/ had the highest number of valid cross-correlations, while the speech token /s/ had the lowest number. CONCLUSIONS This study successfully compared aCAEP and eCAEP in CI users. Both acoustic and electrical P1-N1-P2 recordings obtained were clear and reliable, with good correlation. Latency increased with decreasing stimulation level, while amplitude decreased. eCAEP is potentially a better option to verify speech detection at the cortical level because it (1) uses direct stimulation and therefore creates less interference and delay of the sound processor and (2) creates more flexibility with the recording setup and stimulation setting. As such, eCAEP is an alternative method for CI optimization.
Collapse
|
24
|
Sagi E, Azadpour M, Neukam J, Capach NH, Svirsky MA. Reducing interaural tonotopic mismatch preserves binaural unmasking in cochlear implant simulations of single-sided deafness. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:2316. [PMID: 34717490 PMCID: PMC8637719 DOI: 10.1121/10.0006446] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 09/02/2021] [Accepted: 09/08/2021] [Indexed: 06/13/2023]
Abstract
Binaural unmasking, a key feature of normal binaural hearing, can refer to the improved intelligibility of masked speech by adding masking that facilitates perceived separation of target and masker. A question relevant for cochlear implant users with single-sided deafness (SSD-CI) is whether binaural unmasking can still be achieved if the additional masking is spectrally degraded and shifted. CIs restore some aspects of binaural hearing to these listeners, although binaural unmasking remains limited. Notably, these listeners may experience a mismatch between the frequency information perceived through the CI and that perceived by their normal hearing ear. Employing acoustic simulations of SSD-CI with normal hearing listeners, the present study confirms a previous simulation study that binaural unmasking is severely limited when interaural frequency mismatch between the input frequency range and simulated place of stimulation exceeds 1-2 mm. The present study also shows that binaural unmasking is largely retained when the input frequency range is adjusted to match simulated place of stimulation, even at the expense of removing low-frequency information. This result bears implications for the mechanisms driving the type of binaural unmasking of the present study and for mapping the frequency range of the CI speech processor in SSD-CI users.
Collapse
Affiliation(s)
- Elad Sagi
- Department of Otolaryngology-Head & Neck Surgery, New York University Grossman School of Medicine, 550 First Avenue, New York, New York 10016, USA
| | - Mahan Azadpour
- Department of Otolaryngology-Head & Neck Surgery, New York University Grossman School of Medicine, 550 First Avenue, New York, New York 10016, USA
| | - Jonathan Neukam
- Department of Otolaryngology-Head & Neck Surgery, New York University Grossman School of Medicine, 550 First Avenue, New York, New York 10016, USA
| | - Nicole Hope Capach
- Department of Otolaryngology-Head & Neck Surgery, New York University Grossman School of Medicine, 550 First Avenue, New York, New York 10016, USA
| | - Mario A Svirsky
- Department of Otolaryngology-Head & Neck Surgery, New York University Grossman School of Medicine, 550 First Avenue, New York, New York 10016, USA
| |
Collapse
|
25
|
Single-Sided Deafness Cochlear Implant Sound-Localization Behavior With Multiple Concurrent Sources. Ear Hear 2021; 43:206-219. [PMID: 34320529 DOI: 10.1097/aud.0000000000001089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES For listeners with one deaf ear and the other ear with normal/near-normal hearing (single-sided deafness [SSD]) or moderate hearing loss (asymmetric hearing loss), cochlear implants (CIs) can improve speech understanding in noise and sound-source localization. Previous SSD-CI localization studies have used a single source with artificial sounds such as clicks or random noise. While this approach provides insights regarding the auditory cues that facilitate localization, it does not capture the complex nature of localization behavior in real-world environments. This study examined SSD-CI sound localization in a complex scenario where a target sound was added to or removed from a mixture of other environmental sounds, while tracking head movements to assess behavioral strategy. DESIGN Eleven CI users with normal hearing or moderate hearing loss in the contralateral ear completed a sound-localization task in monaural (CI-OFF) and bilateral (CI-ON) configurations. Ten of the listeners were also tested before CI activation to examine longitudinal effects. Two-second environmental sound samples, looped to create 4- or 10-sec trials, were presented in a spherical array of 26 loudspeakers encompassing ±144° azimuth and ±30° elevation at a 1-m radius. The target sound was presented alone (localize task) or concurrently with one or three additional sources presented to different loudspeakers, with the target cued by being added to (Add) or removed from (Rem) the mixture after 6 sec. A head-mounted tracker recorded movements in six dimensions (three for location, three for orientation). Mixed-model regression was used to examine target sound-identification accuracy, localization accuracy, and head movement. Angular and translational head movements were analyzed both before and after the target was switched on or off. RESULTS Listeners showed improved localization accuracy in the CI-ON configuration, but there was no interaction with test condition and no effect of the CI on sound-identification performance. Although high-frequency hearing loss in the unimplanted ear reduced localization accuracy and sound-identification performance, the magnitude of the CI localization benefit was independent of hearing loss. The CI reduced the magnitude of gross head movements used during the task in the azimuthal rotation and translational dimensions, both while the target sound was present (in all conditions) and during the anticipatory period before the target was switched on (in the Add condition). There was no change in pre- versus post-activation CI-OFF performance. CONCLUSIONS These results extend previous findings, demonstrating a CI localization benefit in a complex listening scenario that includes environmental and behavioral elements encountered in everyday listening conditions. The CI also reduced the magnitude of gross head movements used to perform the task. This was the case even before the target sound was added to the mixture. This suggests that a CI can reduce the need for physical movement both in anticipation of an upcoming sound event and while actively localizing the target sound. Overall, these results show that for SSD listeners, a CI can improve localization in a complex sound environment and reduce the amount of physical movement used.
Collapse
|
26
|
Xie Z, Stakhovskaya O, Goupell MJ, Anderson S. Aging Effects on Cortical Responses to Tones and Speech in Adult Cochlear-Implant Users. J Assoc Res Otolaryngol 2021; 22:719-740. [PMID: 34231111 DOI: 10.1007/s10162-021-00804-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Accepted: 05/19/2021] [Indexed: 11/29/2022] Open
Abstract
Age-related declines in auditory temporal processing contribute to speech understanding difficulties of older adults. These temporal processing deficits have been established primarily among acoustic-hearing listeners, but the peripheral and central contributions are difficult to separate. This study recorded cortical auditory evoked potentials from younger to middle-aged (< 65 years) and older (≥ 65 years) cochlear-implant (CI) listeners to assess age-related changes in temporal processing, where cochlear processing is bypassed in this population. Aging effects were compared to age-matched normal-hearing (NH) listeners. Advancing age was associated with prolonged P2 latencies in both CI and NH listeners in response to a 1000-Hz tone or a syllable /da/, and with prolonged N1 latencies in CI listeners in response to the syllable. Advancing age was associated with larger N1 amplitudes in NH listeners. These age-related changes in latency and amplitude were independent of stimulus presentation rate. Further, CI listeners exhibited prolonged N1 and P2 latencies and smaller P2 amplitudes than NH listeners. Thus, aging appears to degrade some aspects of auditory temporal processing when peripheral-cochlear contributions are largely removed, suggesting that changes beyond the cochlea may contribute to age-related temporal processing deficits.
Collapse
Affiliation(s)
- Zilong Xie
- Department of Hearing and Speech, University of Kansas Medical Center, Kansas City, KS, 66160, USA.
| | - Olga Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA
| | - Samira Anderson
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, 20742, USA
| |
Collapse
|
27
|
Bernstein JGW, Stakhovskaya OA, Jensen KK, Goupell MJ. Acoustic Hearing Can Interfere With Single-Sided Deafness Cochlear-Implant Speech Perception. Ear Hear 2021; 41:747-761. [PMID: 31584504 PMCID: PMC7117997 DOI: 10.1097/aud.0000000000000805] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVES Cochlear implants (CIs) restore some spatial advantages for speech understanding in noise to individuals with single-sided deafness (SSD). In addition to a head-shadow advantage when the CI ear has a better signal-to-noise ratio, a CI can also provide a binaural advantage in certain situations, facilitating the perceptual separation of spatially separated concurrent voices. While some bilateral-CI listeners show a similar binaural advantage, bilateral-CI listeners with relatively large asymmetries in monaural speech understanding can instead experience contralateral speech interference. Based on the interference previously observed for asymmetric bilateral-CI listeners, this study tested the hypothesis that in a multiple-talker situation, the acoustic ear would interfere with rather than improve CI speech understanding for SSD-CI listeners. DESIGN Experiment 1 measured CI-ear speech understanding in the presence of competing speech or noise for 13 SSD-CI listeners. Target speech from the closed-set coordinate response-measure corpus was presented to the CI ear along with one same-gender competing talker or stationary noise at target-to-masker ratios between -8 and 20 dB. The acoustic ear was presented with silence (monaural condition) or with a copy of the competing speech or noise (bilateral condition). Experiment 2 tested a subset of 6 listeners in the reverse configuration for which SSD-CI listeners have previously shown a binaural benefit (target and competing speech presented to the acoustic ear; silence or competing speech presented to the CI ear). Experiment 3 examined the possible influence of a methodological difference between experiments 1 and 2: whether the competing talker spoke keywords that were inside or outside the response set. For each experiment, the data were analyzed using repeated-measures logistic regression. For experiment 1, a correlation analysis compared the difference between bilateral and monaural speech-understanding scores to several listener-specific factors: speech understanding in the CI ear, preimplantation duration of deafness, duration of CI experience, ear of deafness (left/right), acoustic-ear audiometric thresholds, and listener age. RESULTS In experiment 1, presenting a copy of the competing speech to the acoustic ear reduced CI speech-understanding scores for target-to-masker ratios ≥4 dB. This interference effect was limited to competing-speech conditions and was not observed for a noise masker. There was dramatic intersubject variability in the magnitude of the interference (range: 1 to 43 rationalized arcsine units), which was found to be significantly correlated with listener age. The interference effect contrasted sharply with the reverse configuration (experiment 2), whereby presenting a copy of the competing speech to the contralateral CI ear significantly improved performance relative to monaural acoustic-ear performance. Keyword condition (experiment 3) did not influence the observed pattern of interference. CONCLUSIONS Most SSD-CI listeners experienced interference when they attended to the CI ear and competing speech was added to the acoustic ear, although there was a large amount of intersubject variability in the magnitude of the effect, with older listeners particularly susceptible to interference. While further research is needed to investigate these effects under free-field listening conditions, these results suggest that for certain spatial configurations in a multiple-talker situation, contralateral speech interference could reduce the benefit that an SSD-CI otherwise provides.
Collapse
Affiliation(s)
- Joshua G. W. Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
| | - Olga A. Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland – College Park, Maryland, USA
| | - Kenneth Kragh Jensen
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
| | - Matthew J. Goupell
- Department of Hearing and Speech Sciences, University of Maryland – College Park, Maryland, USA
| |
Collapse
|
28
|
Angermeier J, Hemmert W, Zirn S. Sound Localization Bias and Error in Bimodal Listeners Improve Instantaneously When the Device Delay Mismatch Is Reduced. Trends Hear 2021; 25:23312165211016165. [PMID: 34057366 PMCID: PMC8182625 DOI: 10.1177/23312165211016165] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Users of a cochlear implant (CI) in one ear, who are provided with a hearing aid (HA) in the contralateral ear, so-called bimodal listeners, are typically affected by a constant and relatively large interaural time delay offset due to differences in signal processing and differences in stimulation. For HA stimulation, the cochlear travelling wave delay is added to the processing delay, while for CI stimulation, the auditory nerve fibers are stimulated directly. In case of MED-EL CI systems in combination with different HA types, the CI stimulation precedes the acoustic HA stimulation by 3 to 10 ms. A self-designed, battery-powered, portable, and programmable delay line was applied to the CI to reduce the device delay mismatch in nine bimodal listeners. We used an A-B-B-A test design and determined if sound source localization improves when the device delay mismatch is reduced by delaying the CI stimulation by the HA processing delay (τHA). Results revealed that every subject in our group of nine bimodal listeners benefited from the approach. The root-mean-square error of sound localization improved significantly from 52.6° to 37.9°. The signed bias also improved significantly from 25.2° to 10.5°, with positive values indicating a bias toward the CI. Furthermore, two other delay values (τHA –1 ms and τHA +1 ms) were applied, and with the latter value, the signed bias was further reduced in some test subjects. We conclude that sound source localization accuracy in bimodal listeners improves instantaneously and sustainably when the device delay mismatch is reduced.
Collapse
Affiliation(s)
- Julian Angermeier
- Peter Osypka Institute of Medical Engineering, Faculty of Electrical Engineering, Medical Engineering and Computer Sciences, University of Applied Sciences Offenburg, Germany
- Bio-Inspired Information Processing, Munich School of Bioengineering, Technical of University Munich, Germany
- Julian Angermeier, Peter Osypka Institute of Medical Engineering, Faculty of Electrical Engineering, Medical Engineering and Computer Sciences, University of Applied Sciences Offenburg, Germany.
| | - Werner Hemmert
- Bio-Inspired Information Processing, Munich School of Bioengineering, Technical of University Munich, Germany
| | - Stefan Zirn
- Peter Osypka Institute of Medical Engineering, Faculty of Electrical Engineering, Medical Engineering and Computer Sciences, University of Applied Sciences Offenburg, Germany
| |
Collapse
|
29
|
Zedan A, Jürgens T, Williges B, Kollmeier B, Wiebe K, Galindo J, Wesarg T. Speech Intelligibility and Spatial Release From Masking Improvements Using Spatial Noise Reduction Algorithms in Bimodal Cochlear Implant Users. Trends Hear 2021; 25:23312165211005931. [PMID: 33926327 PMCID: PMC8113364 DOI: 10.1177/23312165211005931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This study investigated the speech intelligibility benefit of using two different spatial noise reduction algorithms in cochlear implant (CI) users who use a hearing aid (HA) on the contralateral side (bimodal CI users). The study controlled for head movements by using head-related impulse responses to simulate a realistic cafeteria scenario and controlled for HA and CI manufacturer differences by using the master hearing aid platform (MHA) to apply both hearing loss compensation and the noise reduction algorithms (beamformers). Ten bimodal CI users with moderate to severe hearing loss contralateral to their CI participated in the study, and data from nine listeners were included in the data analysis. The beamformers evaluated were the adaptive differential microphones (ADM) implemented independently on each side of the listener and the (binaurally implemented) minimum variance distortionless response (MVDR). For frontal speech and stationary noise from either left or right, an improvement (reduction) of the speech reception threshold of 5.4 dB and 5.5 dB was observed using the ADM, and 6.4 dB and 7.0 dB using the MVDR, respectively. As expected, no improvement was observed for either algorithm for colocated speech and noise. In a 20-talker babble noise scenario, the benefit observed was 3.5 dB for ADM and 7.5 dB for MVDR. The binaural MVDR algorithm outperformed the bilaterally applied monaural ADM. These results encourage the use of beamformer algorithms such as the ADM and MVDR by bimodal CI users in everyday life scenarios.
Collapse
Affiliation(s)
- Ayham Zedan
- Medizinische Physik und Exzellenzcluster "Hearing4all," Carl-von-Ossietzky Universität Oldenburg, Oldenburg, Germany
| | - Tim Jürgens
- Medizinische Physik und Exzellenzcluster "Hearing4all," Carl-von-Ossietzky Universität Oldenburg, Oldenburg, Germany.,Institut für Akustik, Technische Hochschule Lübeck, Lübeck, Germany
| | - Ben Williges
- Medizinische Physik und Exzellenzcluster "Hearing4all," Carl-von-Ossietzky Universität Oldenburg, Oldenburg, Germany.,Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom
| | - Birger Kollmeier
- Medizinische Physik und Exzellenzcluster "Hearing4all," Carl-von-Ossietzky Universität Oldenburg, Oldenburg, Germany
| | - Konstantin Wiebe
- Department of Otorhinolaryngology - Head and Neck Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Julio Galindo
- Department of Otorhinolaryngology - Head and Neck Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Thomas Wesarg
- Department of Otorhinolaryngology - Head and Neck Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
30
|
Abstract
Signal processing algorithms are the hidden components in the audio processor that converts the received acoustic signal into electrical impulses while maintaining as much relevant information as possible. Signal processing algorithms should be smart enough to mimic the functionality of external, middle and the inner-ear to provide the cochlear implant (CI) user with a hearing experience as natural as possible. Modern sound processing strategies are based on the continuous interleaved sampling (CIS) strategy proposed by B. Wilson in 1991, which provided envelope information over several intracochlear electrodes. The CIS strategy brought significant gains in speech perception. Translational research activities of MED-EL resulted in further improvements in speech understanding in noisy environments as well as enjoyment of music by not only coding CIS-based envelope information, but by also representing temporal fine structure information in the stimulation patterns of the apical channels. Further developments include "complete cochlear coverage" made possible by deep insertion of the intracochlear electrode, elaborate front end processing, anatomy based fitting (ABF), triphasic pulse stimulation instrumental in the suppression of facial nerve stimulation, and bimodal delay compensation allowing unilateral CI users to experience hearing with hearing aids on the contralateral ear. The large number of hardware developments might be exemplified by the RONDO, the world's first single unit audio processor in 2013. This article covers the milestones of translational research around the signal processing and audio processor topic that took place in association with MED-EL.
Collapse
Affiliation(s)
| | - Ingeborg Hochmair
- MED-EL Elektromedizinische Geraete Gesellschaft m.b.H., Innsbruck, Austria
| |
Collapse
|
31
|
Hinrichs R, Gajecki T, Ostermann J, Nogueira W. A subjective and objective evaluation of a codec for the electrical stimulation patterns of cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:1324. [PMID: 33639785 DOI: 10.1121/10.0003571] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 02/03/2021] [Indexed: 06/12/2023]
Abstract
Wireless transmission of audio from or to signal processors of cochlear implants (CIs) is used to improve speech understanding of CI users. This transmission requires wireless communication to exchange the necessary data. Because they are battery powered devices, energy consumption needs to be kept low in CIs, therefore making bitrate reduction of the audio signals necessary. Additionally, low latency is essential. Previously, a codec for the electrodograms of CIs, called the Electrocodec, was proposed. In this work, a subjective evaluation of the Electrocodec is presented, which investigates the impact of the codec on monaural speech performance. The Electrocodec is evaluated with respect to speech recognition and quality in ten CI users and compared to the Opus audio codec. Opus is a low latency and low bitrate audio codec that best met the CI requirements in terms of bandwidth, bitrate, and latency. Achieving equal speech recognition and quality as Opus, the Electrocodec achieves lower mean bitrates than Opus. Actual rates vary from 24.3 up to 53.5 kbit/s, depending on the codec settings. While Opus has a minimum algorithmic latency of 5 ms, the Electrocodec has an algorithmic latency of 0 ms.
Collapse
Affiliation(s)
- Reemt Hinrichs
- Institut für Informationsverarbeitung, Leibniz Universität Hannover, Appelstraße 9a, 30167 Hannover, Germany
| | - Tom Gajecki
- Department of Otolaryngology, Medical University Hannover, Karl-Wiechert-Allee 3, 30625 Hannover, Germany
| | - Jörn Ostermann
- Institut für Informationsverarbeitung, Leibniz Universität Hannover, Appelstraße 9a, 30167 Hannover, Germany
| | - Waldo Nogueira
- Department of Otolaryngology, Medical University Hannover, Karl-Wiechert-Allee 3, 30625 Hannover, Germany
| |
Collapse
|
32
|
Lee HJ, Smieja D, Polonenko MJ, Cushing SL, Papsin BC, Gordon KA. Consistent and chronic cochlear implant use partially reverses cortical effects of single sided deafness in children. Sci Rep 2020; 10:21526. [PMID: 33298987 PMCID: PMC7726152 DOI: 10.1038/s41598-020-78371-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 11/10/2020] [Indexed: 01/09/2023] Open
Abstract
Potentially neuroprotective effects of CI use were studied in 22 children with single sided deafness (SSD). Auditory-evoked EEG confirmed strengthened representation of the intact ear in the ipsilateral auditory cortex at initial CI activation in children with early-onset SSD (n = 15) and late-onset SSD occurring suddenly in later childhood/adolescence (n = 7). In early-onset SSD, representation of the hearing ear decreased with chronic CI experience and expected lateralization to the contralateral auditory cortex from the CI increased with longer daily CI use. In late-onset SSD, abnormally high activity from the intact ear in the ipsilateral cortex reduced, but responses from the deaf ear weakened despite CI use. Results suggest that: (1) cortical reorganization driven by unilateral hearing can occur throughout childhood; (2) chronic and consistent CI use can partially reverse these effects; and (3) CI use may not protect children with late-onset SSD from ongoing deterioration of pathways from the deaf ear.
Collapse
Affiliation(s)
- Hyo-Jeong Lee
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada
- Department of Communication Disorders, Hospital for Sick Children, Toronto, ON, Canada
- Department of Otorhinolaryngology-Head and Neck Surgery, Hallym University College of Medicine, Chuncheon, Republic of Korea
| | - Daniel Smieja
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada
- Department of Communication Disorders, Hospital for Sick Children, Toronto, ON, Canada
| | - Melissa Jane Polonenko
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada
- Department of Communication Disorders, Hospital for Sick Children, Toronto, ON, Canada
| | - Sharon Lynn Cushing
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, Toronto, ON, Canada
- Department of Otolaryngology-Head and Neck Surgery, University of Toronto, Toronto, ON, Canada
| | - Blake Croll Papsin
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, Toronto, ON, Canada
- Department of Otolaryngology-Head and Neck Surgery, University of Toronto, Toronto, ON, Canada
| | - Karen Ann Gordon
- Archie's Cochlear Implant Laboratory, Hospital for Sick Children, Rm 6D08, 555 University Ave, Toronto, ON, M5G 1X8, Canada.
- Department of Communication Disorders, Hospital for Sick Children, Toronto, ON, Canada.
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada.
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, Toronto, ON, Canada.
- Department of Otolaryngology-Head and Neck Surgery, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
33
|
Körtje M, Baumann U, Stöver T, Weissgerber T. Sensitivity to interaural time differences and localization accuracy in cochlear implant users with combined electric-acoustic stimulation. PLoS One 2020; 15:e0241015. [PMID: 33075114 PMCID: PMC7571672 DOI: 10.1371/journal.pone.0241015] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 10/07/2020] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES In this study, localization accuracy and sensitivity to acoustic interaural time differences (ITDs) in subjects using cochlear implants with combined electric-acoustic stimulation (EAS) were assessed and compared with the results of a normal hearing control group. METHODS Eight CI users with EAS (2 bilaterally implanted, 6 unilaterally implanted) and symmetric binaural acoustic hearing and 24 normal hearing subjects participated in the study. The first experiment determined mean localization error (MLE) for different angles of sound incidence between ± 60° (frontal and dorsal presentation). The stimuli were either low-pass, high-pass or broadband noise bursts. In a second experiment, just noticeable differences (JND) of ITDs were measured for pure tones of 125 Hz, 250 Hz and 500 Hz (headphone presentation). RESULTS Experiment 1: MLE of EAS subjects was 8.5°, 14.3° and 14.7°, (low-, high-pass and broadband stimuli respectively). In the control group, MLE was 1.8° (broadband stimuli). In the differentiation between sound incidence from front and back, EAS subjects performed on chance level. Experiment 2: The JND-ITDs were 88.7 μs for 125 Hz, 48.8 μs for 250 Hz and 52.9 μs for 500 Hz (EAS subjects). Compared to the control group, JND-ITD for 125 Hz was on the same level of performance. No statistically significant correlation was found between MLE and JND-ITD in the EAS cohort. CONCLUSIONS Near to normal ITD sensitivity in the lower frequency acoustic hearing was demonstrated in a cohort of EAS users. However, in an acoustic localization task, the majority of the subjects did not reached the level of accuracy of normal hearing. Presumably, signal processing time delay differences between devices used on both sides are deteriorating the transfer of precise binaural timing cues.
Collapse
Affiliation(s)
- Monika Körtje
- Audiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany
| | - Uwe Baumann
- Audiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany
| | - Timo Stöver
- ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany
| | - Tobias Weissgerber
- Audiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
34
|
Dirks CE, Nelson PB, Winn MB, Oxenham AJ. Sensitivity to binaural temporal-envelope beats with single-sided deafness and a cochlear implant as a measure of tonotopic match (L). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3626. [PMID: 32486770 PMCID: PMC7253218 DOI: 10.1121/10.0001305] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
For cochlear-implant users with near-normal contralateral hearing, a mismatch between the frequency-to-place mapping in the two ears could produce a suboptimal performance. This study assesses tonotopic matches via binaural interactions. Dynamic interaural time-difference sensitivity was measured using bandpass-filtered pulse trains at different rates in the acoustic and implanted ear, creating binaural envelope beats. Sensitivity to beats should peak when the same tonotopic region is stimulated in both ears. All nine participants detected dynamic interaural timing differences and demonstrated some frequency selectivity. This method provides a guide to frequency-to-place mapping without compensation for inherent latency differences between the acoustic and implanted ears.
Collapse
Affiliation(s)
- Coral E Dirks
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Peggy B Nelson
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Matthew B Winn
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Andrew J Oxenham
- Department of Psychology, University of Minnesota, 75 East River Road, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
35
|
Snapp HA, Ausili SA. Hearing with One Ear: Consequences and Treatments for Profound Unilateral Hearing Loss. J Clin Med 2020; 9:jcm9041010. [PMID: 32260087 PMCID: PMC7230949 DOI: 10.3390/jcm9041010] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 03/28/2020] [Accepted: 03/31/2020] [Indexed: 12/02/2022] Open
Abstract
There is an increasing global recognition of the negative impact of hearing loss, and its association to many chronic health conditions. The deficits and disabilities associated with profound unilateral hearing loss, however, continue to be under-recognized and lack public awareness. Profound unilateral hearing loss significantly impairs spatial hearing abilities, which is reliant on the complex interaction of monaural and binaural hearing cues. Unilaterally deafened listeners lose access to critical binaural hearing cues. Consequently, this leads to a reduced ability to understand speech in competing noise and to localize sounds. The functional deficits of profound unilateral hearing loss have a substantial impact on socialization, learning and work productivity. In recognition of this, rehabilitative solutions such as the rerouting of signal and hearing implants are on the rise. This review focuses on the latest insights into the deficits of profound unilateral hearing impairment, and current treatment approaches.
Collapse
|
36
|
Williges B, Wesarg T, Jung L, Geven LI, Radeloff A, Jürgens T. Spatial Speech-in-Noise Performance in Bimodal and Single-Sided Deaf Cochlear Implant Users. Trends Hear 2020; 23:2331216519858311. [PMID: 31364496 PMCID: PMC6669847 DOI: 10.1177/2331216519858311] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
This study compared spatial speech-in-noise performance in two cochlear implant (CI) patient groups: bimodal listeners, who use a hearing aid contralaterally to support their impaired acoustic hearing, and listeners with contralateral normal hearing, i.e., who were single-sided deaf before implantation. Using a laboratory setting that controls for head movements and that simulates spatial acoustic scenes, speech reception thresholds were measured for frontal speech-in-stationary noise from the front, the left, or the right side. Spatial release from masking (SRM) was then extracted from speech reception thresholds for monaural and binaural listening. SRM was found to be significantly lower in bimodal CI than in CI single-sided deaf listeners. Within each listener group, the SRM extracted from monaural listening did not differ from the SRM extracted from binaural listening. In contrast, a normal-hearing control group showed a significant improvement in SRM when using two ears in comparison to one. Neither CI group showed a binaural summation effect; that is, their performance was not improved by using two devices instead of the best monaural device in each spatial scenario. The results confirm a "listening with the better ear" strategy in the two CI patient groups, where patients benefited from using two ears/devices instead of one by selectively attending to the better one. Which one is the better ear, however, depends on the spatial scenario and on the individual configuration of hearing loss.
Collapse
Affiliation(s)
- Ben Williges
- 1 Medical Physics and Cluster of Excellence "Hearing4all," Carl von Ossietzky University of Oldenburg, Germany
| | - Thomas Wesarg
- 2 Department of Otorhinolaryngology - Head and Neck Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Germany
| | - Lorenz Jung
- 2 Department of Otorhinolaryngology - Head and Neck Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Germany
| | - Leontien I Geven
- 3 Department of Otorhinolaryngology, Head and Neck Surgery, Carl von Ossietzky University of Oldenburg, Germany
| | - Andreas Radeloff
- 3 Department of Otorhinolaryngology, Head and Neck Surgery, Carl von Ossietzky University of Oldenburg, Germany
| | - Tim Jürgens
- 1 Medical Physics and Cluster of Excellence "Hearing4all," Carl von Ossietzky University of Oldenburg, Germany.,4 Institute of Acoustics, University of Applied Sciences Lübeck, Germany
| |
Collapse
|
37
|
Wess JM, Spencer NJ, Bernstein JGW. Counting or discriminating the number of voices to assess binaural fusion with single-sided vocoders. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:446. [PMID: 32006956 PMCID: PMC7043860 DOI: 10.1121/10.0000511] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/27/2019] [Accepted: 12/06/2019] [Indexed: 06/10/2023]
Abstract
For single-sided deafness cochlear-implant (SSD-CI) listeners, different peripheral representations for electric versus acoustic stimulation, combined with interaural frequency mismatch, might limit the ability to perceive bilaterally presented speech as a single voice. The assessment of binaural fusion often relies on subjective report, which requires listeners to have some understanding of the perceptual phenomenon of object formation. Two experiments explored whether binaural fusion could instead be assessed using judgments of the number of voices in a mixture. In an SSD-CI simulation, normal-hearing listeners were presented with one or two "diotic" voices (i.e., unprocessed in one ear and noise-vocoded in the other) in a mixture with additional monaural voices. In experiment 1, listeners reported how many voices they heard. Listeners generally counted the diotic speech as two separate voices, regardless of interaural frequency mismatch. In experiment 2, listeners identified which of two mixtures contained diotic speech. Listeners performed significantly better with interaurally frequency-matched than with frequency-mismatched stimuli. These contrasting results suggest that listeners experienced partial fusion: not enough to count the diotic speech as one voice, but enough to detect its presence. The diotic-speech detection task (experiment 2) might provide a tool to evaluate fusion and optimize frequency mapping for SSD-CI patients.
Collapse
Affiliation(s)
- Jessica M Wess
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA
| | - Nathaniel J Spencer
- Air Force Research Laboratory, Wright Patterson Air Force Base, Ohio 45433, USA
| | - Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA
| |
Collapse
|
38
|
Zirn S, Angermeier J, Arndt S, Aschendorff A, Wesarg T. Reducing the Device Delay Mismatch Can Improve Sound Localization in Bimodal Cochlear Implant/Hearing-Aid Users. Trends Hear 2019; 23:2331216519843876. [PMID: 31018790 PMCID: PMC6484236 DOI: 10.1177/2331216519843876] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In users of a cochlear implant (CI) together with a contralateral hearing aid (HA), so-called bimodal listeners, differences in processing latencies between digital HA and CI up to 9 ms constantly superimpose interaural time differences. In the present study, the effect of this device delay mismatch on sound localization accuracy was investigated. For this purpose, localization accuracy in the frontal horizontal plane was measured with the original and minimized device delay mismatch. The reduction was achieved by delaying the CI stimulation according to the delay of the individually worn HA. For this, a portable, programmable, battery-powered delay line based on a ring buffer running on a microcontroller was designed and assembled. After an acclimatization period to the delayed CI stimulation of 1 hr, the nine bimodal study participants showed a highly significant improvement in localization accuracy of 11.6% compared with the everyday situation without the delay line ( p < .01). Concluding, delaying CI stimulation to minimize the device delay mismatch seems to be a promising method to increase sound localization accuracy in bimodal listeners.
Collapse
Affiliation(s)
- Stefan Zirn
- 1 Department of Electrical Engineering, Medical Engineering and Computer Science, University of Applied Sciences Offenburg, Germany
| | - Julian Angermeier
- 1 Department of Electrical Engineering, Medical Engineering and Computer Science, University of Applied Sciences Offenburg, Germany
| | - Susan Arndt
- 2 Department of Otorhinolaryngology-Head and Neck Surgery, Medical Center, Faculty of Medicine-University of Freiburg, Germany
| | - Antje Aschendorff
- 2 Department of Otorhinolaryngology-Head and Neck Surgery, Medical Center, Faculty of Medicine-University of Freiburg, Germany
| | - Thomas Wesarg
- 2 Department of Otorhinolaryngology-Head and Neck Surgery, Medical Center, Faculty of Medicine-University of Freiburg, Germany
| |
Collapse
|
39
|
Gordon K, Kral A. Animal and human studies on developmental monaural hearing loss. Hear Res 2019; 380:60-74. [DOI: 10.1016/j.heares.2019.05.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 05/29/2019] [Accepted: 05/30/2019] [Indexed: 11/26/2022]
|
40
|
Bernstein JGW, Stakhovskaya OA, Schuchman GI, Jensen KK, Goupell MJ. Interaural Time-Difference Discrimination as a Measure of Place of Stimulation for Cochlear-Implant Users With Single-Sided Deafness. Trends Hear 2019; 22:2331216518765514. [PMID: 29623771 PMCID: PMC5894906 DOI: 10.1177/2331216518765514] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Current clinical practice in programming a cochlear implant (CI) for individuals with single-sided deafness (SSD) is to maximize the transmission of speech information via the implant, with the implicit assumption that this will also result in improved spatial-hearing abilities. However, binaural sensitivity is reduced by interaural place-of-stimulation mismatch, a likely occurrence with a standard CI frequency-to-electrode allocation table (FAT). As a step toward reducing interaural mismatch, this study investigated whether a test of interaural-time-difference (ITD) discrimination could be used to estimate the acoustic frequency yielding the best place match for a given CI electrode. ITD-discrimination performance was measured by presenting 300-ms bursts of 100-pulses-per-second electrical pulse trains to a single CI electrode and band-limited pulse trains with variable carrier frequencies to the acoustic ear. Listeners discriminated between two reference intervals (four bursts each with constant ITD) and a moving target interval (four bursts with variable ITD). For 17 out of the 26 electrodes tested across eight listeners, the function describing the relationship between ITD-discrimination performance and carrier frequency had a discernable peak where listeners achieved 70% to 100% performance. On average, this peak occurred 1.15 octaves above the CI manufacturer’s default FAT. ITD discrimination shows promise as a method of estimating the cochlear place of stimulation for a given electrode, thereby providing information to optimize the FAT for SSD-CI listeners.
Collapse
Affiliation(s)
- Joshua G W Bernstein
- 1 National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, USA
| | - Olga A Stakhovskaya
- 1 National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, USA.,2 Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Gerald I Schuchman
- 1 National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, USA
| | - Kenneth K Jensen
- 1 National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, USA
| | - Matthew J Goupell
- 2 Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| |
Collapse
|
41
|
Seebacher J, Franke-Trieger A, Weichbold V, Zorowka P, Stephan K. Improved interaural timing of acoustic nerve stimulation affects sound localization in single-sided deaf cochlear implant users. Hear Res 2018; 371:19-27. [PMID: 30439571 DOI: 10.1016/j.heares.2018.10.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 09/11/2018] [Accepted: 10/26/2018] [Indexed: 11/17/2022]
Abstract
The main impairment associated with single-sided deafness (SSD) is the loss of binaural hearing. Currently, the most effective treatment to compensate for this deficit is to supply patients suffering from SSD with a cochlear implant (CI) in the deaf ear. With this approach binaural hearing abilities can be restored to a certain extent, which is expressed in an improvement in such patients with regard to sound source localization and speech comprehension in noise after receipt of a CI. However, binaural performance of these listeners does not reach the level of normal-hearing listeners. One of the reasons for this might be that the electrical stimulation via CI and the physiological stimulation via the intact ear are not synchronized: the CI transmits the information to the auditory nerve with different timing than does the intact inner ear. As a result, there is a timing mismatch of the information transfer between the left and the right side, which may account for the limited binaural performance. The effective mismatch in timing depends on the CI system because of different stimulation strategies implemented in devices from different manufacturers. For the particular CI device used in this study (MED-EL Mi1000/Mi1200) electrical stimulation led to faster activation of the auditory nerve than natural for a wide frequency range. In particular, electrical stimulation was about 1 to up to 2 ms ahead of time for frequencies above 1.5 kHz. Hence, it was hypothesized that information transfer between the left and the right ear can be tuned by delaying the CI signal. The goal of the present study was to investigate whether such a delay in the CI signal affects binaural performance of CI users with SSD. For this purpose, sound source localization and speech perception in noise were tested in a sample of 12 CI users with SSD (mean age 51 ± 12 years). The tests were performed for four different delay times of the CI signal applied spontaneously (0.5, 1, 2 and 4 ms) and for the base line condition "no delay" in the CI signal (i.e. everyday use). It was found that delaying the signal had a significant impact on sound source localization. Speech perception in noise was affected, but less pronounced than was sound localization. Regarding sound source localization, a signal delay of 1 ms applied to this particular CI device produced the best performance in our patients. It is concluded that improving the synchronisation between the CI-transferred signal and the naturally transferred signal could increase binaural hearing performance in CI users with SSD.
Collapse
Affiliation(s)
- J Seebacher
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria.
| | - A Franke-Trieger
- Saxonian Cochlear Implant Center, Department of Otorhinolaryngology, Technical University of Dresden, Germany
| | - V Weichbold
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| | - P Zorowka
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| | - K Stephan
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| |
Collapse
|
42
|
Interaural Time Difference Perception with a Cochlear Implant and a Normal Ear. J Assoc Res Otolaryngol 2018; 19:703-715. [PMID: 30264229 DOI: 10.1007/s10162-018-00697-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Accepted: 09/04/2018] [Indexed: 01/16/2023] Open
Abstract
Currently there is a growing population of cochlear-implant (CI) users with (near) normal hearing in the non-implanted ear. This configuration is often called SSD (single-sided deafness) CI. The goal of the CI is often to improve spatial perception, so the question raises to what extent SSD CI listeners are sensitive to interaural time differences (ITDs). In a controlled lab setup, sensitivity to ITDs was investigated in 11 SSD CI listeners. The stimuli were 100-pps pulse trains on the CI side and band-limited click trains on the acoustic side. After determining level balance and the delay needed to achieve synchronous stimulation of the two ears, the just noticeable difference in ITD was measured using an adaptive procedure. Seven out of 11 listeners were sensitive to ITDs, with a median just noticeable difference of 438 μs. Out of the four listeners who were not sensitive to ITD, one listener reported binaural fusion, and three listeners reported no binaural fusion. To enable ITD sensitivity, a frequency-dependent delay of the electrical stimulus was required to synchronize the electric and acoustic signals at the level of the auditory nerve. Using subjective fusion measures and refined by ITD sensitivity, it was possible to match a CI electrode to an acoustic frequency range. This shows the feasibility of these measures for the allocation of acoustic frequency ranges to electrodes when fitting a CI to a subject with (near) normal hearing in the contralateral ear.
Collapse
|
43
|
Abstract
OBJECTIVES Cochlear-implant (CI) users with single-sided deafness (SSD)-that is, one normal-hearing (NH) ear and one CI ear-can obtain some unmasking benefits when a mixture of target and masking voices is presented to the NH ear and a copy of just the masking voices is presented to the CI ear. NH listeners show similar benefits in a simulation of SSD-CI listening, whereby a mixture of target and masking voices is presented to one ear and a vocoded copy of the masking voices is presented to the opposite ear. However, the magnitude of the benefit for SSD-CI listeners is highly variable across individuals and is on average less than for NH listeners presented with vocoded stimuli. One possible explanation for the limited benefit observed for some SSD-CI users is that temporal and spectral discrepancies between the acoustic and electric ears might interfere with contralateral unmasking. The present study presented vocoder simulations to NH participants to examine the effects of interaural temporal and spectral mismatches on contralateral unmasking. DESIGN Speech-reception performance was measured in a competing-talker paradigm for NH listeners presented with vocoder simulations of SSD-CI listening. In the monaural condition, listeners identified target speech masked by two same-gender interferers, presented to the left ear. In the bilateral condition, the same stimuli were presented to the left ear, but the right ear was presented with a noise-vocoded copy of the interfering voices. This paradigm tested whether listeners could integrate the interfering voices across the ears to better hear the monaural target. Three common distortions inherent in CI processing were introduced to the vocoder processing: spectral shifts, temporal delays, and reduced frequency selectivity. RESULTS In experiment 1, contralateral unmasking (i.e., the benefit from adding the vocoded maskers to the second ear) was impaired by spectral mismatches of four equivalent rectangular bandwidths or greater. This is equivalent to roughly a 3.6-mm mismatch between the cochlear places stimulated in the electric and acoustic ears, which is on the low end of the average expected mismatch for SSD-CI listeners. In experiment 2, performance was negatively affected by a temporal mismatch of 24 ms or greater, but not for mismatches in the 0 to 12 ms range expected for SSD-CI listeners. Experiment 3 showed an interaction between spectral shift and spectral resolution, with less effect of interaural spectral mismatches when the number of vocoder channels was reduced. Experiment 4 applied interaural spectral and temporal mismatches in combination. Performance was best when both frequency and timing were aligned, but in cases where a mismatch was present in one dimension (either frequency or latency), the addition of mismatch in the second dimension did not further disrupt performance. CONCLUSIONS These results emphasize the need for interaural alignment-in timing and especially in frequency-to maximize contralateral unmasking for NH listeners presented with vocoder simulations of SSD-CI listening. Improved processing strategies that reduce mismatch between the electric and acoustic ears of SSD-CI listeners might improve their ability to obtain binaural benefits in multitalker environments.
Collapse
|
44
|
Polonenko MJ, Gordon KA, Cushing SL, Papsin BC. Cortical organization restored by cochlear implantation in young children with single sided deafness. Sci Rep 2017; 7:16900. [PMID: 29203800 PMCID: PMC5715123 DOI: 10.1038/s41598-017-17129-z] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Accepted: 11/22/2017] [Indexed: 11/23/2022] Open
Abstract
Early treatment of single sided deafness in children has been recommended to protect from neurodevelopmental preference for the better hearing ear and from social and educational deficits. A fairly homogeneous group of five young children (≤3.6 years of age) with normal right sided hearing who received a cochlear implant to treat deafness in their left ears were studied. Etiology of deafness was largely cytomegalovirus (n = 4); one child had an enlarged vestibular aqueduct. Multi-channel electroencephalography of cortical evoked activity was measured repeatedly over time at: 1) acute (0.5 ± 0.7 weeks); 2) early chronic (1.1 ± 0.2 months); and 3) chronic (5.8 ± 3.4 months) cochlear implant stimulation. Results indicated consistent responses from the normal right ear with marked changes in activity from the implanted left ear. Atypical distribution of peak amplitude activity from the implanted ear at acute stimulation marked abnormal lateralization of activity to the ipsilateral left auditory cortex and recruitment of extra-temporal areas including left frontal cortex. These abnormalities resolved with chronic implant use and contralateral aural preference emerged in both auditory cortices. These findings indicate that early implantation in young children with single sided deafness can rapidly restore bilateral auditory input to the cortex needed to improve binaural hearing.
Collapse
Affiliation(s)
- Melissa Jane Polonenko
- Institute of Medical Sciences, The University of Toronto, Toronto, ON, M5S 1A8, Canada.
- Neurosciences and Mental Health, The Hospital for Sick Children, Toronto, ON, M5G 1X8, Canada.
| | - Karen Ann Gordon
- Institute of Medical Sciences, The University of Toronto, Toronto, ON, M5S 1A8, Canada
- Neurosciences and Mental Health, The Hospital for Sick Children, Toronto, ON, M5G 1X8, Canada
- Department of Otolaryngology - Head & Neck Surgery, The University of Toronto, Toronto, ON, M5G 2N2, Canada
- Otolaryngology - Head & Neck Surgery, The Hospital for Sick Children, Toronto, ON, M5G 1X8, Canada
| | - Sharon Lynn Cushing
- Institute of Medical Sciences, The University of Toronto, Toronto, ON, M5S 1A8, Canada
- Department of Otolaryngology - Head & Neck Surgery, The University of Toronto, Toronto, ON, M5G 2N2, Canada
- Otolaryngology - Head & Neck Surgery, The Hospital for Sick Children, Toronto, ON, M5G 1X8, Canada
| | - Blake Croll Papsin
- Institute of Medical Sciences, The University of Toronto, Toronto, ON, M5S 1A8, Canada
- Department of Otolaryngology - Head & Neck Surgery, The University of Toronto, Toronto, ON, M5G 2N2, Canada
- Otolaryngology - Head & Neck Surgery, The Hospital for Sick Children, Toronto, ON, M5G 1X8, Canada
| |
Collapse
|
45
|
Binaural integration: a challenge to overcome for children with hearing loss. Curr Opin Otolaryngol Head Neck Surg 2017; 25:514-519. [DOI: 10.1097/moo.0000000000000413] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
46
|
Polonenko MJ, Papsin BC, Gordon KA. Delayed access to bilateral input alters cortical organization in children with asymmetric hearing. NEUROIMAGE-CLINICAL 2017; 17:415-425. [PMID: 29159054 PMCID: PMC5683809 DOI: 10.1016/j.nicl.2017.10.036] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 10/25/2017] [Accepted: 10/31/2017] [Indexed: 11/19/2022]
Abstract
Bilateral hearing in early development protects auditory cortices from reorganizing to prefer the better ear. Yet, such protection could be disrupted by mismatched bilateral input in children with asymmetric hearing who require electric stimulation of the auditory nerve from a cochlear implant in their deaf ear and amplified acoustic sound from a hearing aid in their better ear (bimodal hearing). Cortical responses to bimodal stimulation were measured by electroencephalography in 34 bimodal users and 16 age-matched peers with normal hearing, and compared with the same measures previously reported for 28 age-matched bilateral implant users. Both auditory cortices increasingly favoured the better ear with delay to implanting the deaf ear; the time course mirrored that occurring with delay to bilateral implantation in unilateral implant users. Preference for the implanted ear tended to occur with ongoing implant use when hearing was poor in the non-implanted ear. Speech perception deteriorated with longer deprivation and poorer access to high-frequencies. Thus, cortical preference develops in children with asymmetric hearing but can be avoided by early provision of balanced bimodal stimulation. Although electric and acoustic stimulation differ, these inputs can work sympathetically when used bilaterally given sufficient hearing in the non-implanted ear.
Collapse
Affiliation(s)
- Melissa Jane Polonenko
- Institute of Medical Sciences, University of Toronto, Toronto, ON M5S 1A8, Canada; Neurosciences & Mental Health, Hospital for Sick Children, Toronto, ON M5G 1X8, Canada.
| | - Blake Croll Papsin
- Department of Otolaryngology - Head & Neck Surgery, University of Toronto, Toronto, ON M5G 2N2, Canada; Otolaryngology - Head & Neck Surgery, Hospital for Sick Children, Toronto, ON M5G 1X8, Canada
| | - Karen Ann Gordon
- Institute of Medical Sciences, University of Toronto, Toronto, ON M5S 1A8, Canada; Neurosciences & Mental Health, Hospital for Sick Children, Toronto, ON M5G 1X8, Canada; Department of Otolaryngology - Head & Neck Surgery, University of Toronto, Toronto, ON M5G 2N2, Canada; Otolaryngology - Head & Neck Surgery, Hospital for Sick Children, Toronto, ON M5G 1X8, Canada
| |
Collapse
|
47
|
Cochlear Implantation in Cases of Unilateral Hearing Loss: Initial Localization Abilities. Ear Hear 2017; 38:611-619. [DOI: 10.1097/aud.0000000000000430] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
48
|
Zirn S, Arndt S, Aschendorff A, Laszig R, Wesarg T. Perception of Interaural Phase Differences With Envelope and Fine Structure Coding Strategies in Bilateral Cochlear Implant Users. Trends Hear 2016; 20:20/0/2331216516665608. [PMID: 27659487 PMCID: PMC5036260 DOI: 10.1177/2331216516665608] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation.
Collapse
Affiliation(s)
- Stefan Zirn
- Department of Oto-Rhino-Laryngology of the Medical Center, University of Freiburg, Germany University of Applied Sciences Offenburg, Germany
| | - Susan Arndt
- Department of Oto-Rhino-Laryngology of the Medical Center, University of Freiburg, Germany
| | - Antje Aschendorff
- Department of Oto-Rhino-Laryngology of the Medical Center, University of Freiburg, Germany
| | - Roland Laszig
- Department of Oto-Rhino-Laryngology of the Medical Center, University of Freiburg, Germany
| | - Thomas Wesarg
- Department of Oto-Rhino-Laryngology of the Medical Center, University of Freiburg, Germany
| |
Collapse
|
49
|
|