1
|
Shao N, Skotak M, Pendyala N, Rodriguez J, Ravula AR, Pang K, Perumal V, Rao KVR, Chandra N. Temporal Changes in Functional and Structural Neuronal Activities in Auditory System in Non-Severe Blast-Induced Tinnitus. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1683. [PMID: 37763802 PMCID: PMC10535376 DOI: 10.3390/medicina59091683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/30/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023]
Abstract
Background and Objectives: Epidemiological data indicate that blast exposure is the most common morbidity responsible for mild TBI among Service Members (SMs) during recent military operations. Blast-induced tinnitus is a comorbidity frequently reported by veterans, and despite its wide prevalence, it is also one of the least understood. Tinnitus arising from blast exposure is usually associated with direct structural damage that results in a conductive and sensorineural impairment in the auditory system. Tinnitus is also believed to be initiated by abnormal neuronal activities and temporal changes in neuroplasticity. Clinically, it is observed that tinnitus is frequently accompanied by sleep disruption as well as increased anxiety. In this study, we elucidated some of the mechanistic aspects of sensorineural injury caused by exposure to both shock waves and impulsive noise. The isolated conductive auditory damage hypothesis was minimized by employing an animal model wherein both ears were protected. Materials and Methods: After the exposure, the animals' hearing circuitry status was evaluated via acoustic startle response (ASR) to distinguish between hearing loss and tinnitus. We also compared the blast-induced tinnitus against the well-established sodium salicylate-induced tinnitus model as the positive control. The state of the sensorineural auditory system was evaluated by auditory brainstem response (ABR), and this test helped examine the neuronal circuits between the cochlea and inferior colliculus. We then further evaluated the role of the excitatory and inhibitory neurotransmitter receptors and neuronal synapses in the auditory cortex (AC) injury after blast exposure. Results: We observed sustained elevated ABR thresholds in animals exposed to blast shock waves, while only transient ABR threshold shifts were observed in the impulsive noise group solely at the acute time point. These changes were in concert with the increased expression of ribbon synapses, which is suggestive of neuroinflammation and cellular energy metabolic disorder. It was also found that the onset of tinnitus was accompanied by anxiety, depression-like symptoms, and altered sleep patterns. By comparing the effects of shock wave exposure and impulsive noise exposure, we unveiled that the shock wave exerted more significant effects on tinnitus induction and sensorineural impairments when compared to impulsive noise. Conclusions: In this study, we systematically studied the auditory system structural and functional changes after blast injury, providing more significant insights into the pathophysiology of blast-induced tinnitus.
Collapse
Affiliation(s)
- Ningning Shao
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Maciej Skotak
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Navya Pendyala
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Jose Rodriguez
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Arun Reddy Ravula
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Kevin Pang
- NeuroBehavioral Research Laboratory, VA New Jersey Health Care System, Research and Development (Mailstop 15), 385 Tremont Ave, East Orange, NJ 07018, USA
- Department of Pharmacology, Physiology and Neuroscience, Rutgers-New Jersey Medical School, Newark, NJ 07103, USA
| | - Venkatesan Perumal
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Kakulavarapu V. Rama Rao
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| | - Namas Chandra
- Center for Injury Biomechanics, Materials and Medicine, Department of Biomedical Engineering, New Jersey Institute of Technology, 111 Lock Street, Newark, NJ 07102, USA
| |
Collapse
|
2
|
Dobrev I, Pfiffner F, Röösli C. Intracochlear pressure and temporal bone motion interaction under bone conduction stimulation. Hear Res 2023; 435:108818. [PMID: 37267833 DOI: 10.1016/j.heares.2023.108818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 05/16/2023] [Accepted: 05/25/2023] [Indexed: 06/04/2023]
Abstract
BACKGROUND Under bone conduction (BC) stimulation, the otic capsule, and surrounding temporal bone, undergoes a complex 3-dimentional (3D) motion that depends on the frequency, location and coupling of the stimulation. The correlation between the resultant intracochlear pressure difference across the cochlear partition and the 3D motion of the otic capsule is not yet known and is to be investigated. METHODS Experiments were conducted in 3 fresh frozen cadaver heads, individually on each temporal bone, resulting in a total of 6 samples. The skull bone was stimulated, via the actuator of a BC hearing aid (BCHA), in the frequency range of 0.1-20 kHz. Stimulation was applied at the ipsilateral mastoid and the classical BAHA location via a conventional transcutaneous (5-N steel headband) and percutaneous coupling, sequentially. Three-dimensional motions were measured across the lateral and medial (intracranial) surfaces of the skull, the ipsilateral temporal bone, the skull base, as well as the promontory and stapes. Each measurement consisted of 130-200 measurement points (∼5-10 mm pitch) across the measured skull surface. Additionally, intracochlear pressure in the scala tympani and scala vestibuli was measured via a custom-made intracochlear acoustic receiver. RESULTS While there were limited differences in the magnitude of the motion across the skull base, there were major differences in the deformation of different sections of the skull. Specifically, the bone near the otic capsule remained primarily rigid across all test frequency (above 10 kHz), in contrast to the skull base, which deformed above 1-2 kHz. Above 1 kHz, the ratio, between the differential intracochlear pressure and the promontory motion, was relatively independent of coupling and stimulation location. Similarly, the stimulation direction appears to have no influence on the cochlear response, above 1 kHz. CONCLUSIONS The area around the otic capsule appears rigid up to significantly higher frequencies than the rest of the skull surface, resulting in primarily inertial loading of the cochlear fluid. Further work should be focused at the investigation of the solid-fluid interaction between the bony walls of the otic capsule and the cochlear contents.
Collapse
Affiliation(s)
- Ivo Dobrev
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 24, Zurich CH-8091, Switzerland.
| | - Flurin Pfiffner
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 24, Zurich CH-8091, Switzerland
| | - Christof Röösli
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 24, Zurich CH-8091, Switzerland
| |
Collapse
|
3
|
Argo Iv TF, Wagner CD, Walilko TJ, Bentley TB. Transfer Function for Relative Blast Overpressure Through Porcine and Human Skulls In Situ. Mil Med 2023; 188:e607-e614. [PMID: 34677614 DOI: 10.1093/milmed/usab412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/08/2021] [Accepted: 09/27/2021] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION The overarching objective of the Office of Naval Research sponsored Blast Load Assessment Sense and Test (BLAST) program was to quantify neurofunctional risk from repeated blast exposure. However, human studies have limitations in data collection that can only be addressed by animal models. To utilize a large animal model in this work, researchers developed an approach for scaling blast exposure data from animal to human-equivalent loading. For this study, energy interacting with the brain tissue was selected as a translation metric because of the hypothesized association between observed neurological changes and energy transmitted through the skull. This article describes the methodology used to derive an energy-based transfer function capable of serving as a global correspondence rule for primary blast injury exposure, allowing researchers to derive human-appropriate thresholds from animal data. METHODS AND MATERIALS To generate data for the development of the transfer functions, three disarticulated cadaveric Yucatan minipigs and three postmortem human surrogate heads were exposed to blast overpressure using a large bore, compressed-gas shock tube. Pressure gauges in the free field, on the skull surface, and pressure probes within the brain cavity filled with Sylgard silicone gel recorded the pressure propagation through the skull of each specimen. The frequency components of the freefield and brain cavity measurements from the pig and human surrogates were interrogated in the frequency domain. Doing so quantifies the differences in the amount of energy, in each frequency band, transmitted through both the porcine and the human skull, and the transfer function was calculated to quantify those differences. RESULTS Nonlinear energy transmission was observed for both the porcine and human skulls, indicating that linear scaling would not be appropriate for developing porcine to human transfer functions. This study demonstrated similar responses between species with little to no attenuation at frequencies below 30 Hz. The phase of the pressure transmission to the brain is also similar for both species up to approximately 10 kHz. There were two notable differences between the porcine and human surrogates. First, in the 40-100 Hz range, human subjects have approximately 8 dB more pressure transmitted through the skull relative to porcine subjects. Second, in the 1-10 kHz range, human subjects have up to 10 dB more pressure transmitted into the brain (10 dB more attenuation) relative to the porcine subjects. CONCLUSIONS The fundamental goal of this study was to develop pig-to-human transfer functions to allow researchers to interpret data collected from large animal studies and aid in deriving risk functions for repeated blast exposures. Similarities in porcine and human brain physiology make the minipig experimental model an excellent candidate for blast research. However, differences in the skull geometry have historically made the interpretation of animal data difficult for the purposes of characterizing potential neurological risk in humans. Human equivalent loading conditions are critical so that the thresholds are not over- or underpredicted due to differences in porcine skull geometry. This research provides a solution to this challenge, providing a robust methodology for interpreting animal data for blast research.
Collapse
|
4
|
Bien AG, Jiang S, Gan RZ. Real-time measurement of stapes motion and intracochlear pressure during blast exposure. Hear Res 2023; 429:108702. [PMID: 36669259 DOI: 10.1016/j.heares.2023.108702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 12/19/2022] [Accepted: 01/12/2023] [Indexed: 01/15/2023]
Abstract
Blast-induced auditory injury is primarily caused by exposure to an overwhelming amount of energy transmitted into the external auditory canal, the middle ear, and then the cochlea. Quantification of this energy requires real-time measurement of stapes footplate (SFP) motion and intracochlear pressure in the scala vestibuli (Psv). To date, SFP and Psv have not been measured simultaneously during blast exposure, but a dual-laser experimental approach for detecting the movement of the SFP was reported by Jiang et al. (2021). In this study, we have incorporated the measurement of Psv with SFP motion and developed a novel approach to quantitatively measure the energy flux entering the cochlea during blast exposure. Five fresh human cadaveric temporal bones (TBs) were used in this study. A mastoidectomy and facial recess approach were performed to identify the SFP, followed by a cochleostomy into the scala vestibuli (SV). The TB was mounted to the "head block", a fixture to simulate a real human skull, with two pressure sensors - one inserted into the SV (Psv) and another in the ear canal near the tympanic membrane (P1). The TB was exposed to the blast overpressure (P0) around 4 psi or 28 kPa. Two laser Doppler vibrometers (LDVs) were used to measure the movements of the SFP and TB (as a reference). The LDVs, P1, and Psv signals were triggered by P0 and recorded simultaneously. The results include peak values for Psv of 100.8 ± 51.6 kPa (mean ± SD) and for SFP displacement of 72.6 ± 56.4 μm, which are consistent with published experimental results and finite element modeling data. Most of the P0 input energy flux into the cochlea occurred within 2 ms and resulted in 10-70 μJ total energy entering the cochlea. Although the middle ear pressure gain was close to that measured under acoustic stimulus conditions, the nonlinear behavior of the middle ear was observed from the elevated cochlear input impedance. For the first time, SFP movement and intracochlear pressure Psv have been successfully measured simultaneously during blast exposure. This study provides a new methodology and experimental data for determining the energy flux entering the cochlea during a blast, which serves as an injury index for quantifying blast-induced auditory damage.
Collapse
Affiliation(s)
- Alexander G Bien
- School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK, United States; Department of Otolaryngology-Head & Neck Surgery, University of Oklahoma Medical Center, Oklahoma City, OK, United States
| | - Shangyuan Jiang
- School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK, United States
| | - Rong Z Gan
- School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK, United States.
| |
Collapse
|
5
|
Occluded insertion loss from intracochlear pressure measurements during acoustic shock wave exposure. Hear Res 2023; 428:108669. [PMID: 36565603 DOI: 10.1016/j.heares.2022.108669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 12/08/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022]
Abstract
INTRODUCTION Injuries to the peripheral auditory system are among the most common results of high intensity impulsive noise exposure. Hearing protection can mitigate this injury, but careful assessment of the insertion loss they provide is necessary. Insertion loss is typically measured using microphone-based acoustic manikins to measure the decrease in sound pressure level transmitted into the ear canal, which precisely measure the change in air conducted sound, but neglect alternate pathways to the inner ear such as bone conduction. In a previous study we reported intracochlear pressures in cadaveric human specimens to acoustic shock waves, which revealed a substantial bone conducted component (Greene, et al., 2018). Here we evaluate insertion loss to several hearing protection devices (HPDs) in those same specimens using intracochlear pressure measurements. METHODS Human cadaver heads were exposed to impulsive acoustic pressure waves with peak overpressures of 7 and 28 kPa (171 & 183 dB SPL). Ear canal (EAC), middle ear, and intracochlear sound pressure levels were measured bilaterally with fiber-optic pressure sensors. Surface-mounted sensors measured SPL and skull strain near the opening of each EAC and at the forehead. Responses were measured with specimen ears unoccluded, as reported previously, as well as fitted with four types of HPDs. Impulse peak insertion loss (IPIL) and impulse spectrum insertion loss (ISIL) were calculated for each HPD. RESULTS For all HPDs, IPIL generally increases with exposure level, though ISIL tended to be more consistent, and the spectral characteristics across frequency appear to be highly dependent on exposure level. ISIL measured in the ear canal tended to overestimate insertion loss measured in the cochlea, particularly at frequencies > 1 kHz; however, low signal-to-noise in intracochlear pressures limited comparisons. As a proof of concept, 36 low-level unoccluded exposures, were averaged together, and the resulting signal-to-noise ratio was improved by up to 15 dB. CONCLUSIONS Insertion loss measured in the cochlea was lower than in the ear canal, suggesting substantial contributions from transmission pathways in parallel with air conduction (e.g., bone conduction) were present, which will require novel strategies to mitigate. However, high variance was observed, and noise reduction strategies should be utilized in future studies to facilitate more precise insertion loss estimates.
Collapse
|
6
|
Dobrev I, Farahmandi T, Pfiffner F, Röösli C. Intracochlear pressure in cadaver heads under bone conduction and intracranial fluid stimulation. Hear Res 2022; 421:108506. [DOI: 10.1016/j.heares.2022.108506] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 03/16/2022] [Accepted: 04/07/2022] [Indexed: 01/20/2023]
|
7
|
Kaliyappan K, Nakuci J, Preda M, Schweser F, Muldoon S, Krishnan Muthaiah VP. Correlation of Histomorphometric Changes with Diffusion Tensor Imaging for Evaluation of Blast-Induced Auditory Neurodegeneration in Chinchilla. J Neurotrauma 2021; 38:3248-3259. [PMID: 34605670 DOI: 10.1089/neu.2020.7556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In the present study, we have evaluated the blast-induced auditory neurodegeneration in chinchilla by correlating the histomorphometric changes with diffusion tensor imaging. The chinchillas were exposed to single unilateral blast-overpressure (BOP) at ∼172dB peak sound pressure level (SPL) and the pathological changes were compared at 1 week and 1 month after BOP. The functional integrity of the auditory system was assessed by auditory brainstem response (ABR) and distortion product otoacoustic emissions (DPOAE). The axonal integrity was assessed using diffusion tensor imaging at regions of interests (ROIs) of the central auditory neuraxis (CAN) including the cochlear nucleus (CN), inferior colliculus (IC), and auditory cortex (AC). Post-BOP, cyto-architecture metrics such as viable cells, degenerating neurons, and apoptotic cells were quantified at the CAN ROIs using light microscopic studies using cresyl fast violet, hematoxylin and eosin, and modified Crossmon's trichrome stains. We observed mean ABR threshold shifts of 30- and 10-dB SPL at 1 week and 1 month after BOP, respectively. A similar pattern was observed in DPAOE amplitudes shift. In the CAN ROIs, diffusion tensor imaging studies showed a decreased axial diffusivity in CN 1 month after BOP and a decreased mean diffusivity and radial diffusivity at 1 week after BOP. However, morphometric measures such as decreased viable cells and increased degenerating neurons and apoptotic cells were observed at CN, IC, and AC. Specifically, increased degenerating neurons and reduced viable cells were high on the ipsilateral side when compared with the contralateral side. These results indicate that a single blast significantly damages structural and functional integrity at all levels of CAN ROIs.
Collapse
Affiliation(s)
- Kathiravan Kaliyappan
- Department of Rehabilitation Sciences, School of Public Health and Health Professions, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| | - Johan Nakuci
- Neuroscience Program, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| | - Marilena Preda
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA.,Center for Biomedical Imaging, Clinical and Translational Science Institute, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| | - Ferdinand Schweser
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA.,Center for Biomedical Imaging, Clinical and Translational Science Institute, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| | - Sarah Muldoon
- Department of Mathematics, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| | - Vijaya Prakash Krishnan Muthaiah
- Department of Rehabilitation Sciences, School of Public Health and Health Professions, College of Arts and Sciences, University at Buffalo, Buffalo, New York, USA
| |
Collapse
|
8
|
Eroglu S, Dizdar HT, Cevizci R, Cengiz AB, Ogreden S, Bulut E, Ilgezdi S, Dilci A, Ustun S, Sirvanci S, Cilingir-Kaya OT, Bayazit D, Cakir BO, Oktay MF, Bayazit Y. Repeated Atmospheric Pressure Alteration Effect on the Cochlea in Rats: Experimental Animal Study. Aerosp Med Hum Perform 2021; 92:550-555. [PMID: 34503628 DOI: 10.3357/amhp.5732.2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVE: This study aimed to evaluate the effects of repeated pressure alterations on cochlear structures in rats in an attempt to understand indirectly the inner ear status of flight crew who are repeatedly exposed to pressure alterations.METHODS: There were 12 adult Wistar albino rats equally divided into 2 groups: Group 1 (controls) and Group 2 (study group). The animals in Group 2 were exposed to repeated pressure changes in a pressure cabin which is regulated by manometers. The animals in Group 1 were placed in the cabin without being exposed to pressure changes. Auditory brainstem response (ABR) testing was performed in all animals at the beginning and at the end of the study. After 12 wk the animals were sacrificed and their cochleas were investigated using scanning electron microscopy (SEM).RESULTS: In the study group, hearing decreases at 2 kHz, 4 kHz, 6 dB at 8 kHz, and 32 kHz were encountered at the end of 3 mo. On SEM evaluation of the control group, the outer hair cells (OHC) and stereocilia were normal throughout the cochlea. In the study group, there were irregularities in lateral surface connections and separations, collapse, and adhesions in the basal segment of the cochlea and partial loss of stereocilia throughout the cochlea.CONCLUSION: Repeated alterations in the atmospheric pressure can lead to damage in the inner ear with subtle or evident hearing loss. Frequent flyers like air workers may be at risk of inner ear damage, which may be considered an occupational health problem.Eroglu S, Dizdar HT, Cevizci R, Cengiz AB, Ogreden S, Bulut E, Ilgezdi S, Dilci A, Ustun S, Sirvanci S, Kaya OT, Bayazit D, Caki BO, Oktay MF, Bayazit Y. Repeated atmospheric pressure alteration effect on the cochlea in rats: experimental animal study. Aerosp Med Hum Perform. 2021; 92(7):550555.
Collapse
|
9
|
Zemaitis K, Kaliyappan K, Frerichs V, Friedman A, Krishnan Muthaiah VP. Mass spectrometry imaging of blast overpressure induced modulation of GABA/glutamate levels in the central auditory neuraxis of Chinchilla. Exp Mol Pathol 2021; 119:104605. [PMID: 33453279 DOI: 10.1016/j.yexmp.2021.104605] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 01/09/2021] [Accepted: 01/10/2021] [Indexed: 11/15/2022]
Abstract
Acoustic trauma damages inner ear neural structures including cochlear hair cells which result in hearing loss and neurotransmitter imbalances within the synapses of the central auditory pathway. Disruption of GABA/glutamate levels underlies, tinnitus, a phantom perception of sound that persists post-exposure to blast noise which may manifest in tandem with acute/chronic loss of hearing. Many putative theories explain tinnitus physiology based on indirect and direct assays in animal models and humans, although there is no comprehensive evidence to explain the phenomenon. Here, GABA/glutamate levels were imaged and quantified in a blast overpressure model of chinchillas using Fourier transform ion cyclotron resonance mass spectrometry imaging. The direct measurement from whole-brain sections identified the relative levels of GABA/glutamate in the central auditory neuraxis centers including the cochlear nucleus, inferior colliculus, and auditory cortex. These preliminary results provide insight on the homeostasis of GABA/glutamate within whole-brain sections of chinchilla for investigation of the pathomechanism of blast-induced tinnitus.
Collapse
Affiliation(s)
- Kevin Zemaitis
- Chemistry Instrument Center, Department of Chemistry, Natural Sciences Complex, University at Buffalo, State University of New York, Buffalo, NY 14260, USA
| | - Kathiravan Kaliyappan
- Department of Rehabilitation Sciences, School of Publich Health and Health Professions, Kimball Tower, University at Buffalo, State University of New York, Buffalo, NY 14215, USA
| | - Valerie Frerichs
- Chemistry Instrument Center, Department of Chemistry, Natural Sciences Complex, University at Buffalo, State University of New York, Buffalo, NY 14260, USA
| | - Alan Friedman
- Department of Materials Design and Innovation, School of Engineering and Applied Sciences, University at Buffalo, State University of New York, Buffalo, NY 14260, USA
| | - Vijaya Prakash Krishnan Muthaiah
- Department of Rehabilitation Sciences, School of Publich Health and Health Professions, Kimball Tower, University at Buffalo, State University of New York, Buffalo, NY 14215, USA.
| |
Collapse
|
10
|
Ucta C, Mittmann P, Ernst A, Seidl R, Lauer G. Minimizing Intracochlear Pressure: Influence of the Insertion Sheath. Audiol Neurootol 2021; 26:281-286. [PMID: 33647910 DOI: 10.1159/000512466] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 10/21/2020] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Atraumatic cochlear implantation (CI) and insertion of the electrode in particular are major goals of recent CI surgery. Perimodiolar electrode arrays need a stylet or exosheath for insertion. The sheath can influence the intracochlear pressure changes during insertion of the electrode. The aim of this study was to modify the insertion sheath to optimize intracochlear pressure changes. METHODS In an artifical cochlear model, 7 different modified insertion sheaths were used. The intracochlear pressure was measured with a micro-optical sensor in the apical part of the model cochlea. RESULTS Significant lower intracochlear pressure changes were observed when the apical part of the insertion sheath was either shortened or tapered. Modification of the stopper does influence the intracochlear pressure significantly. CONCLUSION Modification of the insertion sheath leads to lower intracochlear pressure gain. The differences and impact on intracochlear pressure changes found in this study underline the importance of even subtle modifications of the electrode insertion technique.
Collapse
Affiliation(s)
- Ceyhun Ucta
- Department of Otolaryngology at ukb, Charité Med School Berlin, Hospital of the University of Berlin, Berlin, Germany
| | - Philipp Mittmann
- Department of Otolaryngology at ukb, Charité Med School Berlin, Hospital of the University of Berlin, Berlin, Germany
| | - Arneborg Ernst
- Department of Otolaryngology at ukb, Charité Med School Berlin, Hospital of the University of Berlin, Berlin, Germany
| | - Rainer Seidl
- Department of Otolaryngology at ukb, Charité Med School Berlin, Hospital of the University of Berlin, Berlin, Germany
| | - Gina Lauer
- Department of Otolaryngology at ukb, Charité Med School Berlin, Hospital of the University of Berlin, Berlin, Germany,
| |
Collapse
|
11
|
Dual-laser measurement of human stapes footplate motion under blast exposure. Hear Res 2021; 403:108177. [PMID: 33524791 DOI: 10.1016/j.heares.2021.108177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 12/24/2020] [Accepted: 01/18/2021] [Indexed: 11/21/2022]
Abstract
Hearing damage is one of the most frequently observed injuries in Service members and Veterans even though hearing protection devices (HPDs, e.g. earplugs) have been implemented to prevent blast-induced hearing loss. However, the formation and prevention mechanism of the blast-induced hearing damage remains unclear due to the difficulty for conducting biomechanical measurements in ears during blast exposure. Recently, an approach reported by Jiang et al. (2019) used two laser Doppler vibrometers (LDVs) to measure the motion of the tympanic membrane (TM) in human temporal bones during blast exposure. Using the dual laser setup, we further developed the technology to detect the movement of the stapes footplate (SFP) in ears with and without HPDs while under blast exposure. Eight fresh human cadaveric temporal bones (TBs) were involved in this study. The TB was mounted in a "head block" after performing a facial recess surgery to access the SFP, and a pressure sensor was inserted near the TM in the ear canal to measure the pressure reaching the TM (P1). The TB was exposed to a blast overpressure measuring around 7 psi or 48 kPa at the entrance of the ear canal (P0). Two LDVs were used to measure the vibrations of the SFP and TB (as a reference). The exact motion of the SFP was determined by subtracting the TB motion from the SFP data. Results included a measured peak-to-peak SFP displacement of 68.7 ± 31.6 μm (mean ± SD) from all eight TBs without HPDs. In five of the TBs, the insertion of a foam earplug reduced the SFP displacement from 48.3 ± 6.3 μm to 21.8 ± 10.4 μm. The time-frequency analysis of the SFP velocity signals indicated that most of the energy spectrum was concentrated at frequencies below 4 kHz within the first 2 ms after blast and the energy was reduced after the insertion of HPDs. This study describes a new methodology to quantitatively characterize the response of the middle ear and the energy entering the cochlea during blast exposure. The experimental data are critical for determining the injury of the peripheral auditory system and elucidating the damage formation and prevention mechanism in an ear exposed to blast.
Collapse
|
12
|
Trevino M, Lobarinas E, Maulden AC, Heinz MG. The chinchilla animal model for hearing science and noise-induced hearing loss. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3710. [PMID: 31795699 PMCID: PMC6881193 DOI: 10.1121/1.5132950] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 09/19/2019] [Accepted: 09/24/2019] [Indexed: 05/07/2023]
Abstract
The chinchilla animal model for noise-induced hearing loss has an extensive history spanning more than 50 years. Many behavioral, anatomical, and physiological characteristics of the chinchilla make it a valuable animal model for hearing science. These include similarities with human hearing frequency and intensity sensitivity, the ability to be trained behaviorally with acoustic stimuli relevant to human hearing, a docile nature that allows many physiological measures to be made in an awake state, physiological robustness that allows for data to be collected from all levels of the auditory system, and the ability to model various types of conductive and sensorineural hearing losses that mimic pathologies observed in humans. Given these attributes, chinchillas have been used repeatedly to study anatomical, physiological, and behavioral effects of continuous and impulse noise exposures that produce either temporary or permanent threshold shifts. Based on the mechanistic insights from noise-exposure studies, chinchillas have also been used in pre-clinical drug studies for the prevention and rescue of noise-induced hearing loss. This review paper highlights the role of the chinchilla model in hearing science, its important contributions, and its advantages and limitations.
Collapse
Affiliation(s)
- Monica Trevino
- School of Behavioral and Brain Sciences, Callier Center, The University of Texas at Dallas, 1966 Inwood Road, Dallas, Texas 75235, USA
| | - Edward Lobarinas
- School of Behavioral and Brain Sciences, Callier Center, The University of Texas at Dallas, 1966 Inwood Road, Dallas, Texas 75235, USA
| | - Amanda C Maulden
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| | - Michael G Heinz
- Weldon School of Biomedical Engineering, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| |
Collapse
|
13
|
Rosowski JJ, Remenschneider AK, Tao Cheng J. Limitations of present models of blast-induced sound power conduction through the external and middle ear. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3978. [PMID: 31795712 PMCID: PMC6881194 DOI: 10.1121/1.5132288] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The use of models to predict the effect of blast-like impulses on hearing function is an ongoing topic of investigation relevant to hearing protection and hearing-loss prevention in the modern military. The first steps in the hearing process are the collection of sound power from the environment and its conduction through the external and middle ear into the inner ear. Present efforts to quantify the conduction of high-intensity sound power through the auditory periphery depend heavily on modeling. This paper reviews and elaborates on several existing models of the conduction of high-level sound from the environment into the inner ear and discusses the shortcomings of these models. A case is made that any attempt to more accurately define the workings of the middle ear during high-level sound stimulation needs to be based on additional data, some of which has been recently gathered.
Collapse
Affiliation(s)
- John J Rosowski
- Eaton-Peabody Laboratory and Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, USA
| | - Aaron K Remenschneider
- Eaton-Peabody Laboratory and Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, USA
| | - Jeffrey Tao Cheng
- Eaton-Peabody Laboratory and Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, USA
| |
Collapse
|