1
|
Koch M, Eßinger TM, Maier H, Sim JH, Ren L, Greene NT, Zahnert T, Neudert M, Bornitz M. Methods and reference data for middle ear transfer functions. Sci Rep 2022; 12:17241. [PMID: 36241675 PMCID: PMC9568555 DOI: 10.1038/s41598-022-21245-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 09/26/2022] [Indexed: 01/06/2023] Open
Abstract
Human temporal bone specimens are used in experiments measuring the sound transfer of the middle ear, which is the standard method used in the development of active and passive middle ear implants. Statistical analyses of these experiments usually require that the TB samples are representative of the population of non-pathological middle ears. Specifically, this means that the specimens must be mechanically well-characterized. We present an in-depth statistical analysis of 478 data sets of middle ear transfer functions (METFs) from different laboratories. The data sets are preprocessed and various contributions to the variance of the data are evaluated. We then derive a statistical range as a reference against which individual METF measurements may be validated. The range is calculated as the two-sided 95% tolerance interval at audiological frequencies. In addition, the mean and 95% confidence interval of the mean are given as references for assessing the validity of a sample group. Finally, we provide a suggested procedure for measuring METFs using the methods described herein.
Collapse
Affiliation(s)
- M Koch
- Faculty of Medicine Carl Gustav Carus, ERCD-Ear Research Center Dresden at the Department of Otorhinolaryngology Head and Neck Surgery, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| | - T M Eßinger
- Faculty of Medicine Carl Gustav Carus, ERCD-Ear Research Center Dresden at the Department of Otorhinolaryngology Head and Neck Surgery, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| | - H Maier
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1a, 30625, Hannover, Germany
- Cluster of Excellence "Hearing4all", Hannover, Germany
| | - J H Sim
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - L Ren
- Eye and ENT Hospital of Fudan University, Fenyang Road 83, Shanghai, 200031, China
| | - N T Greene
- Department of Otolaryngology-Head and Neck Surgery, University of Colorado School of Medicine, Aurora, CO, USA
| | - T Zahnert
- Faculty of Medicine Carl Gustav Carus, ERCD-Ear Research Center Dresden at the Department of Otorhinolaryngology Head and Neck Surgery, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - M Neudert
- Faculty of Medicine Carl Gustav Carus, ERCD-Ear Research Center Dresden at the Department of Otorhinolaryngology Head and Neck Surgery, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - M Bornitz
- Faculty of Medicine Carl Gustav Carus, ERCD-Ear Research Center Dresden at the Department of Otorhinolaryngology Head and Neck Surgery, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| |
Collapse
|
2
|
Abstract
Active middle ear implants or implantable hearing aids are used to treat sensorineural or combined hearing loss. Their coupling to the middle ear structures has a large impact on the success of rehabilitation. Practical issues such as the coupling site, influence of middle ear status, and forward and backward excitation of the inner ear are discussed in the context of biomechanics. For this purpose, experimental studies, model simulations, and current literature data are evaluated. The explanations are intended to contribute to a better understanding of certain procedures in hearing rehabilitation with active implants.
Collapse
|
3
|
Eßinger TM, Koch M, Bornitz M, Lasurashvili N, Neudert M, Zahnert T. Sensor-actuator component for a Floating Mass Transducer-based fully implantable hearing aid. Hear Res 2019; 378:157-165. [PMID: 30905594 DOI: 10.1016/j.heares.2019.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 03/01/2019] [Accepted: 03/10/2019] [Indexed: 11/18/2022]
Abstract
We propose a novel system based on the Floating Mass Transducer (FMT) to be used as the active component of a fully implantable, Vibrant Soundbridge-like middle ear implant. The new system replaces the external microphone used in the currently available design with an implantable piezoelectric sensor that is inserted into the incudostapedial joint and picks up the vibrations transmitted to the long process of the incus. The FMT is coupled to the round window of the cochlea. We characterize the system by measuring the gain in intracochlear sound pressure using laser Doppler vibrometry at a surgically installed "third window" into the cochlea of six temporal bones. Closed-loop feedback oscillations limit the system's available output. We show that using an adaptive control algorithm, a mean functional gain of up to 40 dB is achieved, which is similar to Soundbridge functional gain. The concept matches the FMT's one-point fixation philosophy and offers several advantages over other designs, namely an easy and time-efficient surgery, reversibility of implantation, and natural hearing for the prospective patient.
Collapse
Affiliation(s)
- Till Moritz Eßinger
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany.
| | - Martin Koch
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany
| | - Matthias Bornitz
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany
| | - Nikoloz Lasurashvili
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany
| | - Marcus Neudert
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany
| | - Thomas Zahnert
- Technische Universitaet Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, ERCD Ear Research Center Dresden, Germany
| |
Collapse
|