1
|
Bodin A, Texier I, Bisson A, Pierre B, Herbert J, Jacobs M, Nasarre M, Bernard A, Fauchier L. Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study. Europace 2024; 26:euae238. [PMID: 39271128 PMCID: PMC11424992 DOI: 10.1093/europace/euae238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 08/31/2024] [Accepted: 09/09/2024] [Indexed: 09/15/2024] Open
Abstract
AIMS In complete atrioventricular block (AVB) with underlying sinus rhythm, it is recommended to implant a dual-chamber pacemaker rather than a single-chamber pacemaker. However, no large-scale study has been able to demonstrate the superiority of this choice on hard clinical criteria such as morbimortality. METHODS AND RESULTS This retrospective observational study included all patients who received a primary pacemaker implantation in the indication of complete AVB with underlying sinus rhythm in France, based on the national administrative database between January 2013 and December 2022. After propensity score matching, we obtained two groups containing 19 219 patients each. The incidence of all-cause mortality was 9.22%/year for the dual-chamber pacemaker group, compared with 11.48%/year for the single-chamber pacemaker group (hazard ratio (HR) 0.807, P < 0.0001]. Similarly, there was a lower incidence of cardiovascular mortality (HR 0.766, P < 0.0001), heart failure (HR 0.908, P < 0.0001), atrial fibrillation (HR 0.778, P < 0.0001), and ischaemic stroke (HR 0.873, P = 0.008) in the dual-chamber pacemaker group than in the single-chamber pacemaker group. Regarding re-interventions and complications, there were fewer upgrades (addition of atrial lead or left ventricular lead) in the dual-chamber group (HR 0.210, P < 0.0001), but more haematomas (HR 1.179, P = 0.006) and lead repositioning (HR 1.123, P = 0.04). CONCLUSION In the indication of complete AVB with underlying sinus rhythm, our results are consistent with current recommendations to prefer implantation of a dual-chamber pacemaker rather than a single-chamber pacemaker for these patients. Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.
Collapse
Affiliation(s)
- Alexandre Bodin
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Ivann Texier
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Arnaud Bisson
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Bertrand Pierre
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Julien Herbert
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
- Service d'Information Médicale, D'épidémiologie et d'Économie de la Santé, Centre Hospitalier Universitaire et EA7505, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Mathieu Jacobs
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Mathieu Nasarre
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Anne Bernard
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Laurent Fauchier
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| |
Collapse
|
2
|
Yu Q, Fu Q, Xia Y, Wu Y. Predictors, clinical impact, and management strategies for conduction abnormalities after transcatheter aortic valve replacement: an updated review. Front Cardiovasc Med 2024; 11:1370244. [PMID: 38650916 PMCID: PMC11033487 DOI: 10.3389/fcvm.2024.1370244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 03/27/2024] [Indexed: 04/25/2024] Open
Abstract
Transcatheter aortic valve replacement (TAVR) has increasingly become a safe, feasible, and widely accepted alternative surgical treatment for patients with severe symptomatic aortic stenosis. However, the incidence of conduction abnormalities associated with TAVR, including left bundle branch block (LBBB) and high-degree atrioventricular block (HAVB), remains high and is often correlated with risk factors such as the severity of valvular calcification, preexisting conditions in patients, and procedural factors. The existing research results on the impact of post-TAVR conduction abnormalities and permanent pacemaker (PPM) requirements on prognosis, including all-cause mortality and rehospitalization, remain contradictory, with varied management strategies for post-TAVR conduction system diseases across different institutions. This review integrates the latest research in the field, offering a comprehensive discussion of the mechanisms, risk factors, consequences, and management of post-TAVR conduction abnormalities. This study provides insights into optimizing patient prognosis and explores the potential of novel strategies, such as conduction system pacing, to minimize the risk of adverse clinical outcomes.
Collapse
Affiliation(s)
| | | | | | - Yanqing Wu
- Department of Cardiology, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| |
Collapse
|
3
|
Dykun I, Mahabadi AA, Jehn S, Kalra A, Isogai T, Wazni OM, Kanj M, Krishnaswamy A, Reed GW, Yun JJ, Totzeck M, Jánosi RA, Lind AY, Kapadia SR, Rassaf T, Puri R. The degree of permanent pacemaker dependence and clinical outcomes following transcatheter aortic valve implantation: implications for procedural technique. EUROPEAN HEART JOURNAL OPEN 2023; 3:oead127. [PMID: 38105920 PMCID: PMC10721444 DOI: 10.1093/ehjopen/oead127] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 10/27/2023] [Accepted: 11/30/2023] [Indexed: 12/19/2023]
Abstract
Aims Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and results This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI): 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047]. Conclusion Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.
Collapse
Affiliation(s)
- Iryna Dykun
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Amir Abbas Mahabadi
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Stefanie Jehn
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Ankur Kalra
- Krannert Cardiovascular Research Center, Division of Cardiovascular Medicine, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Toshiaki Isogai
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Oussama M Wazni
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Mohamad Kanj
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Amar Krishnaswamy
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Grant W Reed
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - James J Yun
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Matthias Totzeck
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - R Alexander Jánosi
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Alexander Y Lind
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Samir R Kapadia
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| | - Tienush Rassaf
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany
| | - Rishi Puri
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA
| |
Collapse
|
4
|
Madanat L, Seeley E, Mando R, Shah K, Hanson I, Renard BM, Abbas AE, Keeley J, Haines DE, Mehta NK. Mortality Outcomes in Patients With Cardiac Implantable Electronic Devices Before and After Transcatheter Aortic Valve Replacement. Am J Cardiol 2023; 205:1-9. [PMID: 37573632 DOI: 10.1016/j.amjcard.2023.07.098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 08/15/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) carries a risk of high-grade AV block requiring cardiac implantable electronic device (CIED) implantation, which has been associated with a higher mortality rate. However, the outcomes of TAVR in patients with preexisting CIEDs are not well understood. We conducted a retrospective analysis of consecutive patients who underwent TAVR from December 2014 to December 2019 at our institution. Patients were categorized into 3 groups: preexisting CIED pre-TAVR (group 1), CIED implanted within 30 days after TAVR (group 2), and no CIED implanted (group 3). Cox proportional hazard was conducted to determine the primary end point of all-cause mortality. A total of 366 patients were included, of whom 93 (25.4%), 51 (13.9%), and 222 (60.7%) comprised group 1, 2, and 3, respectively. The median follow-up time was 2.3 years. The all-cause mortality rate was higher in group 1 than group 2 (hazard ratio [HR] 2.60, 95% confidence interval [CI] 1.09 to 6.18, p = 0.03) and group 3 (HR 1.96, 95% CI 1.24 to 3.08, p = 0.004). On the multivariate analysis, there was no statistically significant difference in mortality among the groups (group 1 vs group 2: HR 1.95, 95% CI 0.70 to 5.44, p = 0.20 and group 1 vs group 3: HR 1.27, 95% CI 0.66 to 2.43, p = 0.47). Preoperative hemoglobin ≤12 g/100 ml was an independent predictor of all-cause mortality (HR 1.75, 95% CI 1.10 to 2.80, p = 0.02). Group 1 had a higher 1 year congestive heart failure readmission rate (29%) than group 2 (17.6%) and group 3 (8.1%; p <0.0001). In conclusion, there was no difference in the adjusted long-term survival based on the CIED grouping. However, patients with preexisting CIEDs had higher all-cause mortality and 1-year congestive heart failure readmission rates owing to their higher co-morbidity burden, irrespective of their Society of Thoracic Surgeons score. This can be taken into account for preoperative risk stratification.
Collapse
Affiliation(s)
- Luai Madanat
- Department of Internal Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Elizabeth Seeley
- Oakland University William Beaumont School of Medicine, Rochester, Michigan
| | - Ramy Mando
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Kuldeep Shah
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Ivan Hanson
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Brian M Renard
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Amr E Abbas
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Jacob Keeley
- Oakland University William Beaumont School of Medicine, Rochester, Michigan
| | - David E Haines
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan
| | - Nishaki K Mehta
- Oakland University William Beaumont School of Medicine, Rochester, Michigan; Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, Michigan; Cardiovascular Medicine, University of Virginia, Charlottesville, Virginia.
| |
Collapse
|
5
|
Xu S, Zhang E, Qian Z, Sun J, Zou F, Wang Y, Hou X, Zou J. Mid- to Long-Term Clinical and Echocardiographic Effects of Post-procedural Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis. Front Cardiovasc Med 2022; 9:911234. [PMID: 35837611 PMCID: PMC9275565 DOI: 10.3389/fcvm.2022.911234] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Accepted: 05/30/2022] [Indexed: 01/14/2023] Open
Abstract
Aims To date, the prognostic effects of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) remain controversial. The purpose of this meta-analysis was to investigate the mid- (1 year) to long-term (> 1 year) clinical and echocardiographic effects of post-procedural PPI in patients after TAVR. Methods PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched from the establishment of databases up to 1 December 2021. Studies comparing clinical and echocardiographic outcomes between patients with and without post-TAVR PPI of ≥ 1-year follow-up were collected for further meta-analysis. Results A total of 39 studies comprising of 83,082 patients were included in this meta-analysis. At mid-term follow-up (1 year), the pooled results demonstrated a higher risk of all-cause mortality in patients with post-procedural PPI than those without following TAVR (relative risk (RR), 1.17; 95% CI, 1.10–1.24; P < 0.00001). No significant differences were observed in cardiovascular mortality (RR, 0.86; 95% CI, 0.71–1.03; P = 0.10) or heart failure rehospitalization (RR, 0.91; 95% CI, 0.58–1.44; P = 0.69) at 1-year follow-up. At long-term follow-up (> 1 year), post-TAVR PPI had negative effects on all-cause mortality (RR, 1.18; 95% CI, 1.09–1.28; P < 0.0001) and heart failure rehospitalization (RR, 1.42; 95% CI, 1.18–1.71; P = 0.0002). There was no difference in long-term cardiovascular mortality between the two groups (RR, 1.15; 95% CI, 0.97–1.36; P = 0.11). Left ventricular ejection fraction (LVEF) was not significantly different at baseline (mean difference, 1.40; 95% CI, –0.13–2.93; P = 0.07), but was significantly lower in the PPI group at 1-year follow-up (mean difference, –3.57; 95% CI, –4.88 to –2.26; P < 0.00001). Conclusion Our meta-analysis provides evidence that post-TAVR PPI has negative clinical and echocardiographic effects on patients at mid- to long-term follow-up. Further studies are urgently needed to explore the cause of these complications and optimize the treatment and management of patients requiring permanent pacing after TAVR. Systematic Review Registration [https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021289935], identifier [CRD42021289935].
Collapse
Affiliation(s)
- Shun Xu
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Enrui Zhang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Zhiyong Qian
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jinyu Sun
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Fengwei Zou
- Montefiore Medical Center, Bronx, NY, United States
| | - Yao Wang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Xiaofeng Hou
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jiangang Zou
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
6
|
Szecel D, Lamberigts M, Rega F, Verbrugghe P, Dubois C, Meuris B. Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively. Interact Cardiovasc Thorac Surg 2022; 35:6605855. [PMID: 35689614 PMCID: PMC9272061 DOI: 10.1093/icvts/ivac157] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Revised: 04/25/2022] [Accepted: 06/08/2022] [Indexed: 01/30/2023] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS Retrospective analysis of patients implanted with the Perceval valve between 2007 and 2019 was performed by comparing patients implanted before the modification of sizing strategy (OLD group) and after (NEW group). The outcome parameters evaluated were the implanted prosthesis size, haemodynamical profile and postoperative pacemaker implantation. RESULTS The entire patient cohort (784 patients) consisted of 52% female patients, with a mean age of 78.53 [standard deviation (SD): 5.8] years and a mean EuroSCORE II of 6.3 (range 0.7-76). In 55.5% of cases, surgery was combined. The NEW cohort had more male patients (54.6% vs 43.4%) (P = 0.002). Mean implanted valve size, corrected for body surface area, was significantly lower in the NEW cohort (13.1, SD: 1.4 vs 13.5, SD: 1.4 mm/m2, P < 0.001). The 30-day mortality was 3.4%. Peak and mean transvalvular gradients at discharge were significantly lower in the NEW versus OLD groups: 24.4 mmHg (SD: 9.2) versus 28.4 mmHg (SD: 10.3) (P < 0.001) and 13.6 mmHg (SD: 5.3) versus 15.5 mmHg (SD: 6.0) (P < 0.001). The mean effective opening area and the indexed effective opening area, respectively, increased from 1.5 cm2 (SD: 0.5) and 0.85 cm2/m2 (SD: 0.27) in the OLD group to 1.7 cm2 (SD: 0.5) and 0.93 cm2/m2 (SD: 0.30) in the NEW group (P < 0.001). No difference was found in paravalvular leakage ≥1/4. Centrovalvular leakage ≥1/4 significantly decreased from 18% to 7.9% (P < 0.001). With the new sizing, the new postoperative pacemaker implantation rate decreased significantly from 11% to 6.1% (P = 0.016). CONCLUSIONS Correct sizing of sutureless aortic valves is crucial to obtain the best possible haemodynamics and avoid complications.
Collapse
Affiliation(s)
- Delphine Szecel
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.,Department of Cardiovascular Surgery, CHU de Liège, Liège, Belgium
| | - Marie Lamberigts
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Filip Rega
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Peter Verbrugghe
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Christophe Dubois
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Bart Meuris
- Department of Cardiovascular Sciences-Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| |
Collapse
|
7
|
Madanat L, Seeley E, Shah K, Mando R, Hanson I, Abbas A, Renard BM, Haines DE, Mehta N. Transcatheter aortic valve replacement: does timing of cardiac implantable electronic device implantation impact mortality? J Interv Card Electrophysiol 2022; 65:3-5. [PMID: 35759161 DOI: 10.1007/s10840-022-01286-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 06/20/2022] [Indexed: 11/26/2022]
Affiliation(s)
- Luai Madanat
- Department of Internal Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Elizabeth Seeley
- Oakland University William Beaumont School of Medicine, Rochester, MI, USA
| | - Kuldeep Shah
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Ramy Mando
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Ivan Hanson
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Amr Abbas
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Brian M Renard
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - David E Haines
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA
| | - Nishaki Mehta
- Department of Cardiovascular Medicine, William Beaumont Hospital, Royal Oak, MI, USA.
- Oakland University School of Medicine, Rochester, MI, USA.
- Adjunct Faculty, University of Virginia, Charlottesville, VA, USA.
| |
Collapse
|
8
|
Lee KH, Yagishita A, Ohno Y, Sakai T, Sakai K, Miyamoto J, Horinouchi H, Sakama S, Kamioka N, Murakami T, Ayabe K, Amino M, Yoshioka K, Ikari Y. Late-onset atrioventricular block after transcatheter aortic valve replacement. Heart Rhythm O2 2022; 2:607-613. [PMID: 34988505 PMCID: PMC8703188 DOI: 10.1016/j.hroo.2021.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background Conduction disturbances leading to permanent pacemaker implantation (PPI) rarely occur late after transcatheter aortic valve replacement (TAVR). The clinical features of this phenomenon and its association with periprocedural conduction disturbances remain uncertain. Objectives We aimed to determine the incidence and characteristics of late-onset atrioventricular block (AVB) after TAVR. Methods This single-center study included 246 patients undergoing TAVR. Late-onset AVB was defined as AVB ≥1 month after the TAVR. Results Periprocedural AVB (periAVB) occurred in 43 patients (17%). Patients with periAVB had a higher rate of right bundle branch block (47% vs 7%, P < .0001). Of the 43 patients with periAVB, 15 underwent PPI (35%) at a median duration of 6 days, whereas 1 of the remaining 203 patients without periAVB underwent PPI within 1 month (0.5%). During a median follow-up duration of 365 days, late-onset AVB occurred in 10 of 230 patients without PPI within 1 month (4%) at a median duration of 76 days. All 10 patients presented transient periprocedural atrioventricular conduction disturbances, including 8 patients with periAVB (80%), all of whom recovered within 1 month, and 9 patients underwent self-expanding valve implantation (90%). The mortality rate in patients with PPI within 1 month was higher than in those without, although the difference was not statistically significant (hazard ratio 2.68, 95% confidence interval 0.97–9.05, log-rank P = .09). Conclusion Late-onset AVB occurred in a minority of patients undergoing TAVR. Greater vigilance is warranted, particularly in patients with transient conduction disturbances during the periprocedural period following self-expanding valve implantation.
Collapse
Affiliation(s)
| | - Atsuhiko Yagishita
- Address reprint requests and correspondence: Dr Atsuhiko Yagishita, Department of Cardiology, Tokai University, Shimokasuya 143, Isehara, Kanagawa, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Niu HX, Liu X, Gu M, Chen X, Cai C, Cai M, Zhang S, Hua W. Conduction System Pacing for Post Transcatheter Aortic Valve Replacement Patients: Comparison With Right Ventricular Pacing. Front Cardiovasc Med 2021; 8:772548. [PMID: 34917666 PMCID: PMC8669437 DOI: 10.3389/fcvm.2021.772548] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/04/2021] [Indexed: 01/03/2023] Open
Abstract
Introduction: For patients who develop atrioventricular block (AVB) following transcatheter aortic valve replacement (TAVR), right ventricular pacing (RVP) may be associated with adverse outcomes. We assessed the feasibility of conduction system pacing (CSP) in patients who developed AVB following TAVR and compared the procedural and clinical outcomes with RVP. Methods: Consecutive patients who developed AVB following TAVR were prospectively enrolled, and were implanted with RVP or CSP. Procedural and clinical outcomes were compared among different pacing modalities. Results: A total of 60 patients were enrolled, including 10 who were implanted with His bundle pacing (HBP), 20 with left bundle branch pacing (LBBP), and 30 with RVP. The HBP group had significantly lower implant success rate, higher capture threshold, and lower R-wave amplitude than the LBBP and RVP groups (p < 0.01, respectively). The RVP group had a significantly longer paced QRS duration (153.5 ± 6.8 ms, p < 0.01) than the other two groups (HBP: 121.8 ± 8.6 ms; LBBP: 120.2 ± 10.6 ms). During a mean follow-up of 15.0 ± 9.1 months, the LBBP group had significantly higher left ventricular ejection fraction (LVEF) (54.9 ± 6.7% vs. 48.9 ± 9.1%, p < 0.05) and shorter left ventricular end-diastolic diameter (LVEDD) (49.7 ± 5.6 mm vs. 55.0 ± 7.7 mm, p < 0.05) than the RVP group. While the HBP group showed trends of higher LVEF (p = 0.016) and shorter LVEDD (p = 0.017) than the RVP group. Four patients in the RVP group died-three deaths were due to progressive heart failure and one was due to non-cardiac reasons. One death in the LBBP group was due to the non-cardiac reasons. Conclusions: CSP achieved shorter paced QRS duration and better cardiac structure and function in post-TAVR patients than RVP. LBBP had a higher implant success rate and better pacing parameters than HBP.
Collapse
Affiliation(s)
- Hong-Xia Niu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xi Liu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Min Gu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xuhua Chen
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Chi Cai
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Minsi Cai
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Shu Zhang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wei Hua
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
10
|
Velasquez A, Goldberger JJ. Risk of permanent pacemaker implantation after transcatheter aortic valve replacement: How do we manage beyond risk assessment? J Card Surg 2021; 37:406-408. [PMID: 34766370 DOI: 10.1111/jocs.16128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 11/27/2022]
Affiliation(s)
- Alex Velasquez
- Department of Medicine, Cardiovascular Division, University of Miami Leonard M. Miller School of Medicine, Miami, Florida, USA
| | - Jeffrey J Goldberger
- Department of Medicine, Cardiovascular Division, University of Miami Leonard M. Miller School of Medicine, Miami, Florida, USA
| |
Collapse
|