1
|
Zhao X, Bhat A, O’Connor C, Curtin J, Singh B, Tian F. Review of Detection Limits for Various Techniques for Bacterial Detection in Food Samples. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:855. [PMID: 38786811 PMCID: PMC11124167 DOI: 10.3390/nano14100855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 05/07/2024] [Accepted: 05/12/2024] [Indexed: 05/25/2024]
Abstract
Foodborne illnesses can be infectious and dangerous, and most of them are caused by bacteria. Some common food-related bacteria species exist widely in nature and pose a serious threat to both humans and animals; they can cause poisoning, diseases, disabilities and even death. Rapid, reliable and cost-effective methods for bacterial detection are of paramount importance in food safety and environmental monitoring. Polymerase chain reaction (PCR), lateral flow immunochromatographic assay (LFIA) and electrochemical methods have been widely used in food safety and environmental monitoring. In this paper, the recent developments (2013-2023) covering PCR, LFIA and electrochemical methods for various bacterial species (Salmonella, Listeria, Campylobacter, Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli)), considering different food sample types, analytical performances and the reported limit of detection (LOD), are discussed. It was found that the bacteria species and food sample type contributed significantly to the analytical performance and LOD. Detection via LFIA has a higher average LOD (24 CFU/mL) than detection via electrochemical methods (12 CFU/mL) and PCR (6 CFU/mL). Salmonella and E. coli in the Pseudomonadota domain usually have low LODs. LODs are usually lower for detection in fish and eggs. Gold and iron nanoparticles were the most studied in the reported articles for LFIA, and average LODs were 26 CFU/mL and 12 CFU/mL, respectively. The electrochemical method revealed that the average LOD was highest for cyclic voltammetry (CV) at 18 CFU/mL, followed by electrochemical impedance spectroscopy (EIS) at 12 CFU/mL and differential pulse voltammetry (DPV) at 8 CFU/mL. LOD usually decreases when the sample number increases until it remains unchanged. Exponential relations (R2 > 0.95) between LODs of Listeria in milk via LFIA and via the electrochemical method with sample numbers have been obtained. Finally, the review discusses challenges and future perspectives (including the role of nanomaterials/advanced materials) to improve analytical performance for bacterial detection.
Collapse
Affiliation(s)
- Xinyi Zhao
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, D07 ADY7 Dublin, Ireland; (X.Z.); (A.B.); (C.O.); (B.S.)
- FOCAS Research Institute, Technological University Dublin, Camden Row, D08 CKP1 Dublin, Ireland
| | - Abhijnan Bhat
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, D07 ADY7 Dublin, Ireland; (X.Z.); (A.B.); (C.O.); (B.S.)
- MiCRA Biodiagnostics Technology Gateway and Health, Engineering & Materials Sciences (HEMS) Research Hub, Technological University Dublin, D24 FKT9 Dublin, Ireland
| | - Christine O’Connor
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, D07 ADY7 Dublin, Ireland; (X.Z.); (A.B.); (C.O.); (B.S.)
| | - James Curtin
- Faculty of Engineering and Built Environment, Technological University Dublin, Bolton Street, D01 K822 Dublin, Ireland;
| | - Baljit Singh
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, D07 ADY7 Dublin, Ireland; (X.Z.); (A.B.); (C.O.); (B.S.)
- MiCRA Biodiagnostics Technology Gateway and Health, Engineering & Materials Sciences (HEMS) Research Hub, Technological University Dublin, D24 FKT9 Dublin, Ireland
| | - Furong Tian
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, D07 ADY7 Dublin, Ireland; (X.Z.); (A.B.); (C.O.); (B.S.)
- FOCAS Research Institute, Technological University Dublin, Camden Row, D08 CKP1 Dublin, Ireland
| |
Collapse
|
2
|
Zhao Y, Qian Y, Huang Q, Hu X, Gu W, Xing H. Colourimetric and SERS dual-mode aptasensor using Au@Ag and magnetic nanoparticles for the detection of Campylobacter jejuni. Talanta 2024; 270:125585. [PMID: 38150965 DOI: 10.1016/j.talanta.2023.125585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 12/18/2023] [Accepted: 12/21/2023] [Indexed: 12/29/2023]
Abstract
A dual-mode aptasensor has been developed for the effective detection of Campylobacter jejuni (C. jejuni), a major cause of gastrointestinal disease worldwide. The aptasensor utilizes nanoparticles, specifically a core-shell structure consisting of gold and silver (Au@Ag NPs), along with magnetic nanoparticles (MNPs). When Campylobacter jejuni is introduced, "Au@Ag NPs-Aptamer-Campylobacter jejuni-Aptamer-MNPs" sandwich complexes are formed due to the high affinity of the aptamer for the bacterial surface membrane proteins. The dual-mode aptasensor can magnetically enrich the sample in just 15 min, and the presence of Campylobacter jejuni is determined by observing a color change. Additionally, the concentration of Campylobacter jejuni can be quantified using surface-enhanced Raman spectroscopy (SERS) and standard curves. This results in a wider linear range (1.8 × 101-108 CFU/mL) under optimal conditions, a lower limit of detection (6 CFU/mL), and a higher selectivity for the detection of bacteria compared to previously reported sensors. Compared with traditional microbial culture counting methods, the dual-mode aptasensor does not require Raman reporters. The physical action of magnetic enrichment, along with the application of Au@Ag NPs, improves the accuracy of the dual-mode aptasensor, offering the advantages of convenience and high sensitivity. Moreover, by utilizing different types of aptamers, this aptasensor can be modified to detect a wider range of harmful pathogens in various environments.
Collapse
Affiliation(s)
- Yongqiang Zhao
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China
| | - Yong Qian
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China
| | - Qi Huang
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China
| | - Xiaojun Hu
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China
| | - Wenchao Gu
- Shanghai Putuo District Disease Control Center, Shanghai, 200336, China.
| | - Haibo Xing
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai, 201418, China.
| |
Collapse
|
3
|
Nan X, Yao X, Yang L, Cui Y. Lateral flow assay of pathogenic viruses and bacteria in healthcare. Analyst 2023; 148:4573-4590. [PMID: 37655501 DOI: 10.1039/d3an00719g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Healthcare-associated pathogenic viruses and bacteria can have a serious impact on human health and have attracted widespread global attention. The lateral flow assay is a unidirectional detection based on the binding of a target analyte and a bioreceptor on the device via lateral flow. With incredible advantages over traditional chromatographic methods, such as rapid detection, ease of manufacture and cost effectiveness, these test strips are increasingly considered the ideal form for point-of-care applications. This review explores lateral flow assays for pathogenic viruses and bacteria, with a particular focus on methodologies, device components, construction methods, and applications. We anticipate that this review could provide exciting opportunities for developing new lateral flow devices for pathogens and advance related healthcare applications.
Collapse
Affiliation(s)
- Xuanxu Nan
- School of Materials Science and Engineering, Peking University; First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| | - Xuesong Yao
- School of Materials Science and Engineering, Peking University; First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| | - Li Yang
- Peking University First Hospital; Peking University Institute of Nephrology, Beijing 100034, P. R. China.
| | - Yue Cui
- School of Materials Science and Engineering, Peking University; First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| |
Collapse
|
4
|
Liu X, Kukkar D, Deng Z, Yang D, Wang J, Kim KH, Zhang D. "Lock-and-key" recognizer-encoded lateral flow assays toward foodborne pathogen detection: An overview of their fundamentals and recent advances. Biosens Bioelectron 2023; 235:115317. [PMID: 37236010 DOI: 10.1016/j.bios.2023.115317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 04/11/2023] [Indexed: 05/28/2023]
Abstract
In light of severe health risks of foodborne pathogenic bacterial diseases, the potential utility of point-of-care (POC) sensors is recognized for pathogens detection. In this regard, lateral flow assay (LFA) is a promising and user-friendly option for such application among various technological approaches. This article presents a comprehensive review of "lock-and-key" recognizer-encoded LFAs with respect to their working principles and detection performance against foodborne pathogenic bacteria. For this purpose, we describe various strategies for bacteria recognition including the antibody-based antigen-antibody interactions, nucleic acid aptamer-based recognition, and phage-mediated targeting of bacterial cells. In addition, we also outline the technological challenges along with the prospects for the future development of LFA in food analysis. The LFA devices built based upon many recognition strategies are found to have great potential for rapid, convenient, and effective POC detection of pathogens in complex food matrixes. Future developments in this field should emphasize the development of high-quality bio-probes, multiplex sensors, and intelligent portable readers.
Collapse
Affiliation(s)
- Xiaojing Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Deepak Kukkar
- Department of Biotechnology, Chandigarh University, Gharuan, Mohali, 147013, Punjab, India; University Centre for Research and Development, Chandigarh University, Gharuan, Mohali, 147013, Punjab, India
| | - Ziai Deng
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Di Yang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, Seongdong-gu, Wangsimni-ro, Seoul, 04763, South Korea.
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China.
| |
Collapse
|
5
|
Marqués-Fernández JL, Salvador M, Martínez-García JC, Fernández-Miaja P, García-Arribas A, Rivas M. New Perspective on Planar Inductive Sensors: Radio-Frequency Refractometry for Highly Sensitive Quantification of Magnetic Nanoparticles. SENSORS (BASEL, SWITZERLAND) 2023; 23:2372. [PMID: 36904576 PMCID: PMC10007151 DOI: 10.3390/s23052372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 02/13/2023] [Accepted: 02/16/2023] [Indexed: 06/18/2023]
Abstract
We demonstrate how resonant planar coils may be used as sensors to detect and quantify magnetic nanoparticles reliably. A coil's resonant frequency depends on the adjacent materials' magnetic permeability and electric permittivity. A small number of nanoparticles dispersed on a supporting matrix on top of a planar coil circuit may thus be quantified. Such nanoparticle detection has application detection to create new devices to assess biomedicine, food quality assurance, and environmental control challenges. We developed a mathematical model for the inductive sensor response at radio frequencies to obtain the nanoparticles' mass from the self-resonance frequency of the coil. In the model, the calibration parameters only depend on the refraction index of the material around the coil, not on the separate magnetic permeability and electric permittivity. The model compares favourably with three-dimensional electromagnetic simulations and independent experimental measurements. The sensor can be scaled and automated in portable devices to measure small quantities of nanoparticles at a low cost. The resonant sensor combined with the mathematical model is a significant improvement over simple inductive sensors, which operate at smaller frequencies and do not have the required sensitivity, and oscillator-based inductive sensors, which focus on just magnetic permeability.
Collapse
Affiliation(s)
| | - María Salvador
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33203 Gijón, Spain
| | | | - Pablo Fernández-Miaja
- Department of Electrical Engineering, University of Oviedo, Campus de Viesques, 33203 Gijón, Spain
| | - Alfredo García-Arribas
- Department of Electricity and Electronics, University of the Basque Country, 48940 Leioa, Spain
| | - Montserrat Rivas
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33203 Gijón, Spain
| |
Collapse
|
6
|
Deb R, Chaudhary P, Pal P, Tomar RS, Roshan M, Parmanand, Ludri A, Gupta VK, De S. Development of an on-site lateral flow immune assay based on mango leaf derived colloidal silver nanoparticles for rapid detection of Staphylococcus aureus in milk. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2023; 60:132-146. [PMID: 36618039 PMCID: PMC9813322 DOI: 10.1007/s13197-022-05598-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 07/19/2022] [Accepted: 09/09/2022] [Indexed: 01/11/2023]
Abstract
In order to ensure food safety, screening food samples for the presence of pathogens has been categorised as a legal testing item throughout the globe. One of the most prevalent zoonotic bacteria transmitted through dairy milk is Staphylococcus aureus. Given the limitations of the conventional detection methods, in the current study we desigined a competitive lateral flow immune assay (LFIA) using colloidal silver nanoparticles derived from mango leaves for the detection of Staphylococcus aureus in cow milk. SpA, a recombinant protein of Staphylococcus aureus, was used to raised hyperimmune sera used for developing the assay followed by conjugation with the synthesized nanoparticles. To increase the specificity of the assay, the milk samples were prenriched with selective agar exclusively require for Staphyloccocus aureus. The assay was found to be completed within 7-8 h by observing test and control lines in LFIA strips. The developed assay was found to specifically detect the bacteria as low as 1000 cfu/ml of milk samples. With a total 230 number of raw and clinical mastitis milk samples, the assay was validated and achieved relative accuracy, specificity, and sensitivity values of 97.39, 98.03, and 96.1%, respectively. The developed LFIA, which uses economically feasible and stable silver nanoparticles derived from mango leaves, has the potential for routine screening of milk samples for the presence of Staphylococcus aureus, especially in low-resource settings, allowing for early diagnosis, which facilitates effective treatment for the dairy animals and prevents the transmission of the disease in consumers.
Collapse
Affiliation(s)
- Rajib Deb
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
- ICAR-National Research Center On Pig, Guwahati, Assam India
| | - Parul Chaudhary
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | - Prassana Pal
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | - Rahul Singh Tomar
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | - Mayank Roshan
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | - Parmanand
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | - Ashutosh Ludri
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| | | | - Sachinandan De
- Animal Genomics Laboratory, Animal Biotechnology Center, ICAR-National Dairy Research Institute, Karnal-1320021, Haryana India
| |
Collapse
|
7
|
He D, Du Z, Wang Y, Xu E, Jin Z, Wu Z. Quantitative detection of Campylobacter jejuni with a core-satellite assemblies-based dual-modular aptasensor. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.108828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
8
|
Sohrabi H, Majidi MR, Khaki P, Jahanban-Esfahlan A, de la Guardia M, Mokhtarzadeh A. State of the art: Lateral flow assays toward the point-of-care foodborne pathogenic bacteria detection in food samples. Compr Rev Food Sci Food Saf 2022; 21:1868-1912. [PMID: 35194932 DOI: 10.1111/1541-4337.12913] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 12/18/2021] [Accepted: 12/23/2021] [Indexed: 12/24/2022]
Abstract
Diverse chemicals and some physical phenomena recently introduced in nanotechnology have enabled scientists to develop useful devices in the field of food sciences. Concerning such developments, detecting foodborne pathogenic bacteria is now an important issue. These kinds of bacteria species have demonstrated severe health effects after consuming foods and high mortality related to acute cases. The most leading path of intoxication and infection has been through food matrices. Hence, quick recognition of foodborne bacteria agents at low concentrations has been required in current diagnostics. Lateral flow assays (LFAs) are one of the urgent and prevalently applied quick recognition methods that have been settled for recognizing diverse types of analytes. Thus, the present review has stressed on latest developments in LFAs-based platforms to detect various foodborne pathogenic bacteria such as Salmonella, Listeria, Escherichia coli, Brucella, Shigella, Staphylococcus aureus, Clostridium botulinum, and Vibrio cholera. Proper prominence has been given on exactly how the labels, detection elements, or procedures have affected recent developments in the evaluation of diverse bacteria using LFAs. Additionally, the modifications in assays specificity and sensitivity consistent with applied food processing techniques have been discussed. Finally, a conclusion has been drawn for highlighting the main challenges confronted through this method and offered a view and insight of thoughts for its further development in the future.
Collapse
Affiliation(s)
- Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Pegah Khaki
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Ali Jahanban-Esfahlan
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,Department of Biology, Faculty of Fundamental Sciences, University College of Nabi Akram (UCNA), Tabriz, Iran
| | | | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
9
|
Deb R, Pal P, Chaudhary P, Bhadsavle S, Behera M, Parmanand, Gautam D, Roshan M, Vats A, Ludri A, Gupta VK, De S. Development of gold nanoparticle-based visual assay for rapid detection of Escherichia coli specific DNA in milk of cows affected with mastitis. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2021.112901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
10
|
Kang J, Kang D, Yeom G, Park CJ. Molecular Diagnostic System Using Engineered Fusion Protein-Conjugated Magnetic Nanoparticles. Anal Chem 2021; 93:16804-16812. [PMID: 34886672 DOI: 10.1021/acs.analchem.1c03247] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
To effectively control the spread of new infectious diseases, there is a need for highly sensitive diagnostic methods to detect viral nucleic acids rapidly. This study outlines a universal and simple detection strategy that uses magnetic nanoparticles (MNPs) and a novel MagR-MazE fusion protein for molecular diagnostics to facilitate sensitive detection. This study has engineered a novel MNP conjugate that can be generated easily, without using many chemical reagents. The technique is a nucleic acid detection method, using MagR-MazE fusion protein-conjugated MNPs, where the results can be visualized with the naked eye, regardless of the oligonucleotide sequences of the target in the lateral flow assay. This method could sensitively detect polymerase chain reaction (PCR) products of 16S ribosomal RNA (rRNA) and the 2019-nCoV-N-positive control gene in 5 min. It shows a low limit of detection (LoD) of 0.013 ng/μL for dsDNA. It is simpler and more rapid, sensitive, and versatile than other techniques, making it suitable for point-of-care testing. The proposed detection system and MNP conjugation strategy using a fusion protein can be widely applied to various fields requiring rapid on-site diagnosis.
Collapse
Affiliation(s)
- Juyoung Kang
- SB BIOSCIENCE Co., Ltd., Daejeon34141, South Korea
| | - Donguk Kang
- Department of Chemistry, Gwangju Institute of Science and Technology, Gwangju61005, South Korea
| | - Gyuho Yeom
- SB BIOSCIENCE Co., Ltd., Daejeon34141, South Korea
| | - Chin-Ju Park
- Department of Chemistry, Gwangju Institute of Science and Technology, Gwangju61005, South Korea
| |
Collapse
|
11
|
Asakura H, Sakata J, Sasaki Y, Kawatsu K. Development and Evaluation of Fluorescence Immunochromatography for Rapid and Sensitive Detection of Thermophilic Campylobacter. Food Saf (Tokyo) 2021; 9:81-87. [PMID: 34631336 PMCID: PMC8472094 DOI: 10.14252/foodsafetyfscj.d-21-00006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 08/17/2021] [Indexed: 01/08/2023] Open
Abstract
Campylobacter jejuni (C. jejuni) and Campylobacter coli (C. coli) are leading causes of foodborne gastroenteritis in Japan. Epidemiological surveillance has provided evidence that poultry meat is one of the main reservoirs for human campylobacteriosis, and therefore, improvement in process hygiene at slaughter is required to reduce the number of human infections. This study thus aimed to develop fluorescent immunochromatography strips for rapid and sensitive detection of thermophilic Campylobacter on poultry carcasses at slaughter. To establish the required detection levels, we first determined the numbers of C. jejuni and C. coli on poultry carcasses at one large-scale poultry slaughterhouse in Japan, resulting in the detection of Campylobacter at 1.97 ± 0.24 log CFU/25 g of neck skin during the post-chilling process by using ISO 10272-2:2017. Our developed Campylobacter fluorescence immunochromatography (FIC) assay exhibited a 50% limit of detection of 3.51 log CFU or 4.34 log CFU for C. jejuni NCTC 11168 or C. coli JCM 2529, respectively. Inclusive and exclusive tests resulted in good agreement. The practical usefulness of this test toward poultry carcasses should be evaluated in future studies, perhaps concentration of the target microorganisms prior to the testing might be helpful to further enhance sensitivity. Nevertheless, our data suggest the potential of FIC for rapid and sensitive detection of thermophilic Campylobacter for monitoring the process hygiene of poultry carcasses at slaughter.
Collapse
Affiliation(s)
- Hiroshi Asakura
- Division of Biomedical Food Research, National Institute of
Health Sciences, 3-25-26 Tonomachi,Kawasaki-ku, Kawasaki 210-9501, Japan
| | - Junko Sakata
- Bacteriology Section, Osaka Institute of Public Health,
1-3-69 Nakamichi, Higashinari-ku, Osaka 537-0025, Japan
| | - Yoshimasa Sasaki
- Division of Biomedical Food Research, National Institute of
Health Sciences, 3-25-26 Tonomachi,Kawasaki-ku, Kawasaki 210-9501, Japan
| | - Kentaro Kawatsu
- Bacteriology Section, Osaka Institute of Public Health,
1-3-69 Nakamichi, Higashinari-ku, Osaka 537-0025, Japan
| |
Collapse
|
12
|
Sridapan T, Tangkawsakul W, Janvilisri T, Luangtongkum T, Kiatpathomchai W, Chankhamhaengdecha S. Rapid and simultaneous detection of Campylobacter spp. and Salmonella spp. in chicken samples by duplex loop-mediated isothermal amplification coupled with a lateral flow biosensor assay. PLoS One 2021; 16:e0254029. [PMID: 34197563 PMCID: PMC8248736 DOI: 10.1371/journal.pone.0254029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 06/17/2021] [Indexed: 12/15/2022] Open
Abstract
Development of a simple, rapid and specific assay for the simultaneous detection of Campylobacter spp. and Salmonella spp. based on duplex loop-mediated isothermal amplification (d-LAMP), combined with lateral-flow biosensor (LFB) is reported herein. LAMP amplicons of both pathogens were simultaneously amplified and specifically differentiated by LFB. The specificity of the d-LAMP-LFB was evaluated using a set of 68 target and 12 non-target strains, showing 100% inclusivity and exclusivity. The assay can simultaneously detect Campylobacter and Salmonella strains as low as 1 ng and 100 pg genomic DNA per reaction, respectively. The lowest inoculated detection limits for Campylobacter and Salmonella species in artificially contaminated chicken meat samples were 103 CFU and 1 CFU per 25 grams, respectively, after enrichment for 24 h. Furthermore, compared to culture-based methods using field chicken meat samples, the sensitivity, specificity and accuracy of d-LAMP- LFB were 95.6% (95% CI, 78.0%-99.8%), 71.4% (95% CI, 29.0%-96.3%) and 90.0% (95% CI, 73.4%-97.8%), respectively. The developed d-LAMP-LFB assay herein shows great potentials for the simultaneous detection of the Campylobacter and Salmonella spp. and poses a promising alternative approach for detection of both pathogens with applications in food products.
Collapse
Affiliation(s)
- Thanawat Sridapan
- Graduate Program in Molecular Medicine, Faculty of Science, Mahidol University, Bangkok, Thailand
| | - Wanida Tangkawsakul
- Center of Nanoscience and Nanotechnology, Faculty of Science, Mahidol University, Bangkok, Thailand
| | - Tavan Janvilisri
- Department of Biochemistry, Faculty of Science, Mahidol University, Bangkok, Thailand
| | - Taradon Luangtongkum
- Department of Veterinary Public Health, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand
| | - Wansika Kiatpathomchai
- Bioengineering and Sensing Technology Research Team, National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | | |
Collapse
|
13
|
Thornval NR, Hoorfar J. Progress in detection of Campylobacter in the food production chain. Curr Opin Food Sci 2021. [DOI: 10.1016/j.cofs.2020.12.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
14
|
Xiao X, Hu S, Lai X, Peng J, Lai W. Developmental trend of immunoassays for monitoring hazards in food samples: A review. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.02.045] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Liu Y, Zhan L, Qin Z, Sackrison J, Bischof JC. Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis. ACS NANO 2021; 15:3593-3611. [PMID: 33607867 DOI: 10.1021/acsnano.0c10035] [Citation(s) in RCA: 242] [Impact Index Per Article: 80.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Lateral flow assays (LFAs) are paper-based point-of-care (POC) diagnostic tools that are widely used because of their low cost, ease of use, and rapid format. Unfortunately, traditional commercial LFAs have significantly poorer sensitivities (μM) and specificities than standard laboratory tests (enzyme-linked immunosorbent assay, ELISA: pM-fM; polymerase chain reaction, PCR: aM), thus limiting their impact in disease control. In this Perspective, we review the evolving efforts to increase the sensitivity and specificity of LFAs. Recent work to improve the sensitivity through assay improvement includes optimization of the assay kinetics and signal amplification by either reader systems or additional reagents. Together, these efforts have produced LFAs with ELISA-level sensitivities (pM-fM). In addition, sample preamplification can be applied to both nucleic acids (direct amplification) and other analytes (indirect amplification) prior to LFA testing, which can lead to PCR-level (aM) sensitivity. However, these amplification strategies also increase the detection time and assay complexity, which inhibits the large-scale POC use of LFAs. Perspectives to achieve future rapid (<30 min), ultrasensitive (PCR-level), and "sample-to-answer" POC diagnostics are also provided. In the case of LFA specificity, recent research efforts have focused on high-affinity molecules and assay optimization to reduce nonspecific binding. Furthermore, novel highly specific molecules, such as CRISPR/Cas systems, can be integrated into diagnosis with LFAs to produce not only ultrasensitive but also highly specific POC diagnostics. In summary, with continuing improvements, LFAs may soon offer performance at the POC that is competitive with laboratory techniques while retaining a rapid format.
Collapse
Affiliation(s)
- Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Li Zhan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080 United States
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, United States
- Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas 75390, United States
- Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, Texas 75080, United States
| | - James Sackrison
- 3984 Hunters Hill Way, Minnetonka, Minnesota 55345, United States
| | - John C Bischof
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Director, Institute of Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
16
|
Qriouet Z, Cherrah Y, Sefrioui H, Qmichou Z. Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection. Molecules 2021; 26:1058. [PMID: 33670468 PMCID: PMC7922373 DOI: 10.3390/molecules26041058] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 02/01/2021] [Accepted: 02/03/2021] [Indexed: 11/23/2022] Open
Abstract
Lateral flow assays (lateral flow immunoassays and nucleic acid lateral flow assays) have experienced a great boom in a wide variety of early diagnostic and screening applications. As opposed to conventional examinations (High Performance Liquid Chromatography, Polymerase Chain Reaction, Gas chromatography-Mass Spectrometry, etc.), they obtain the results of a sample's analysis within a short period. In resource-limited areas, these tests must be simple, reliable, and inexpensive. In this review, we outline the production process of antibodies against drugs of abuse (such as heroin, amphetamine, benzodiazepines, cannabis, etc.), used in lateral flow immunoassays as revelation or detection molecules, with a focus on the components, the principles, the formats, and the mechanisms of reaction of these assays. Further, we report the monoclonal antibody advantages over the polyclonal ones used against drugs of abuse. The perspective on aptamer use for lateral flow assay development was also discussed as a possible alternative to antibodies in view of improving the limit of detection, sensitivity, and specificity of lateral flow assays.
Collapse
Affiliation(s)
- Zidane Qriouet
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
- Laboratoire de Pharmacologie et Toxicologie, Faculté de Médecine et de Pharmacie, Université Mohammed V-Souissi, Rabat 10100, Morocco;
| | - Yahia Cherrah
- Laboratoire de Pharmacologie et Toxicologie, Faculté de Médecine et de Pharmacie, Université Mohammed V-Souissi, Rabat 10100, Morocco;
| | - Hassan Sefrioui
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
| | - Zineb Qmichou
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
| |
Collapse
|
17
|
Construction, expression and purification of a novel CadF-based multiepitope antigen and its immunogenic polyclonal antibody specific to Campylobacter jejuni and Campylobacter coli. Protein Expr Purif 2021; 180:105818. [PMID: 33418060 DOI: 10.1016/j.pep.2021.105818] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 11/25/2020] [Accepted: 12/30/2020] [Indexed: 11/24/2022]
Abstract
Campylobacteriosis is a disease in humans caused by the infection from Campylobacter spp. Human cases are mainly due to Campylobacter jejuni, although C. coli can cause gastroenteritis in humans as well. The bacteria are commensal in chicken tract and can be contaminated into chicken products during processing. Obviously, detecting reagents such as a specific antibody is essential for the development of immune-based detection methods for C. jejuni or C. coli. In this study, in silico techniques were used to design a chimeric recombinant antigen, named multiepitope antigen (MEA), for the production of specific polyclonal antibody. To design MEA polypeptide based on C. jejuni fibronectin-binding protein or CadF, four conserved and unique antigenic peptides were identified and fused together directly. The C. jejuni CadF-based MEA polypeptide fused with two single six-histidine tags at both C- and N-terminal ends was expressed under Escherichia coli expression system. The recombinant MEA was successfully produced and purified by Ni-NTA resin with a high satisfactory yield. Indirect ELISA results showed that anti-MEA polyclonal antibody derived from rabbit serum had a titer of 16,000, indicating high antigenicity of MEA polypeptide. Dot blot results also confirmed that the produced anti-MEA antibody could specifically recognize both C. jejuni and C. coli whole cells as expected while there was no cross-reactivity to non-Campylobacter spp. tested in this study.
Collapse
|
18
|
Ripolles-Avila C, Martínez-Garcia M, Capellas M, Yuste J, Fung DYC, Rodríguez-Jerez JJ. From hazard analysis to risk control using rapid methods in microbiology: A practical approach for the food industry. Compr Rev Food Sci Food Saf 2020; 19:1877-1907. [PMID: 33337076 DOI: 10.1111/1541-4337.12592] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 05/14/2020] [Accepted: 05/15/2020] [Indexed: 12/14/2022]
Abstract
The prevention of foodborne diseases is one of the main objectives of health authorities. To this effect, analytical techniques to detect and/or quantify the microbiological contamination of foods prior to their release onto the market are required. Management and control of foodborne pathogens have generally been based on conventional detection methodologies, which are not only time-consuming and labor-intensive but also involve high consumable materials costs. However, this management perspective has changed over time given that the food industry requires efficient analytical methods that obtain rapid results. This review covers the historical context of traditional methods and their passage in time through to the latest developments in rapid methods and their implementation in the food sector. Improvements and limitations in the detection of the most relevant pathogens are discussed from a perspective applicable to the current situation in the food industry. Considering efforts that are being done and recent developments, rapid and accurate methods already used in the food industry will be also affordable and portable and offer connectivity in near future, which improves decision-making and safety throughout the food chain.
Collapse
Affiliation(s)
- Carolina Ripolles-Avila
- Area of Human Nutrition and Food Science, Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Maria Martínez-Garcia
- Area of Human Nutrition and Food Science, Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Marta Capellas
- Area of Food Technology, Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Josep Yuste
- Area of Food Technology, Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Daniel Y C Fung
- Call Hall, Department of Animal Sciences and Industry, Kansas State University, Manhattan, Kansas
| | - José-Juan Rodríguez-Jerez
- Area of Human Nutrition and Food Science, Departament de Ciència Animal i dels Aliments, Facultat de Veterinària, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
19
|
Moyano A, Serrano-Pertierra E, Salvador M, Martínez-García JC, Rivas M, Blanco-López MC. Magnetic Lateral Flow Immunoassays. Diagnostics (Basel) 2020; 10:E288. [PMID: 32397264 PMCID: PMC7278001 DOI: 10.3390/diagnostics10050288] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/05/2020] [Accepted: 05/06/2020] [Indexed: 12/13/2022] Open
Abstract
A new generation of magnetic lateral flow immunoassays is emerging as powerful tool for diagnostics. They rely on the use of magnetic nanoparticles (MNP) as detecting label, replacing conventional gold or latex beads. MNPs can be sensed and quantified by means of external devices, allowing the development of immunochromatographic tests with a quantitative capability. Moreover, they have an added advantage because they can be used for immunomagnetic separation (IMS), with improvements in selectivity and sensitivity. In this paper, we have reviewed the current knowledge on magnetic-lateral flow immunoassay (LFIA), coupled with both research and commercially available instruments. The work in the literature has been classified in two categories: optical and magnetic sensing. We have analysed the type of magnetic nanoparticles used in each case, their size, coating, crystal structure and the functional groups for their conjugation with biomolecules. We have also taken into account the analytical characteristics and the type of transduction. Magnetic LFIA have been used for the determination of biomarkers, pathogens, toxins, allergens and drugs. Nanocomposites have been developed as alternative to MNP with the purpose of sensitivity enhancement. Moreover, IMS in combination with other detection principles could also improve sensitivity and limit of detection. The critical analysis in this review could have an impact for the future development of magnetic LFIA in fields requiring both rapid separation and quantification.
Collapse
Affiliation(s)
- Amanda Moyano
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - Esther Serrano-Pertierra
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - María Salvador
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - José Carlos Martínez-García
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - Montserrat Rivas
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - M. Carmen Blanco-López
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| |
Collapse
|
20
|
Recent development in rapid detection techniques for microorganism activities in food matrices using bio-recognition: A review. Trends Food Sci Technol 2020. [DOI: 10.1016/j.tifs.2019.11.007] [Citation(s) in RCA: 91] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
21
|
Masigol M, Fattahi N, Barua N, Lokitz BS, Retterer ST, Platt TG, Hansen RR. Identification of Critical Surface Parameters Driving Lectin-Mediated Capture of Bacteria from Solution. Biomacromolecules 2019; 20:2852-2863. [PMID: 31150217 DOI: 10.1021/acs.biomac.9b00609] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Lectin-functional interfaces are useful for isolation of bacteria from solution because they are low-cost and allow nondestructive, reversible capture. This study provides a systematic investigation of physical and chemical surface parameters that influence bacteria capture over lectin-functionalized polymer interfaces and then applies these findings to construct surfaces with significantly enhanced bacteria capture. The designer block copolymer poly(glycidyl methacrylate)- block-poly(vinyldimethyl azlactone) was used as a lectin attachment layer, and lectin coupling into the polymer film through azlactone-lectin coupling reactions was first characterized. Here, experimental parameters including polymer areal chain density, lectin molecular weight, and lectin coupling buffer were systematically varied to identify parameters driving highest azlactone conversions and corresponding lectin surface densities. To introduce physical nanostructures into the attachment layer, nanopillar arrays (NPAs) of varied heights (300 and 2100 nm) were then used to provide an underlying surface template for the functional polymer layer. Capture of Escherichia coli on lectin-polymer surfaces coated over both flat and NPA surfaces was then investigated. For flat polymer interfaces, bacteria were detected on the surface after incubation at a solution concentration of 103 cfu/mL, and a corresponding detection limit of 1.7 × 103 cfu/mL was quantified. This detection limit was 1 order of magnitude lower than control lectin surfaces functionalized with standard, carbodiimide coupling chemistry. NPA surfaces containing 300 nm tall pillars further improved the detection limit to 2.1 × 102 cfu/mL, but also reduced the viability of captured cells. Finally, to investigate the impact of cell surface parameters on capture, we used Agrobacterium tumefaciens cells genetically modified to allow manipulation of exopolysaccharide adhesin production levels. Statistical analysis of surface capture levels revealed that lectin surface density was the primary factor driving capture, as opposed to exopolysaccharide adhesin expression. These findings emphasize the critical importance of the synthetic interface and the development of surfaces that combine high lectin densities with tailored physical features to drive high levels of capture. These insights will aid in design of biofunctional interfaces with physicochemical surface properties favorable for capture and isolation of bacteria cells from solutions.
Collapse
|
22
|
He D, Wu Z, Cui B, Xu E, Jin Z. Establishment of a dual mode immunochromatographic assay for Campylobacter jejuni detection. Food Chem 2019; 289:708-713. [PMID: 30955670 DOI: 10.1016/j.foodchem.2019.03.106] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 03/15/2019] [Accepted: 03/20/2019] [Indexed: 12/21/2022]
Abstract
Campylobacter jejuni (C. jejuni) is considered one of the most common cause of human gastroenteritis. Aiming to detect C. jejuni in food products rapidly and sensitively, a dual mode lateral flow assay, based on the peroxidase mimicking and surface enhanced Raman scattering (SERS) enhancement properties of platinum coated gold nanorods (AuNR@Pt), was developed in this study. Under color mode and SERS mode, the proposed assay showed good linear response in the range of 102-106 cfu/mL and 102-5 × 106 cfu/mL with limits of detection of 75 cfu/mL and 50 cfu/mL, respectively (S/N = 3). Furthermore, the reliability of the dual-readout lateral flow assay (LFA) was successfully demonstrated by the application on milk samples, in which the recoveries ranged from 89.33% to 107.62%. Overall, the immunochromatographic assay developed in this work is promising and has good chance to be employed for sensitive detection of C. jejuni in food products.
Collapse
Affiliation(s)
- Deyun He
- State Key Laboratory of Plant Physiology and Biochemistry, College of Biological Sciences, China Agricultural University, Beijing 100094, China.
| | - Zhengzong Wu
- State Key Laboratory of Biobased Material and Green Papermaking, College of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China.
| | - Bo Cui
- State Key Laboratory of Biobased Material and Green Papermaking, College of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China.
| | - Enbo Xu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China.
| | - Zhengyu Jin
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| |
Collapse
|
23
|
Singh J, Vishwakarma K, Ramawat N, Rai P, Singh VK, Mishra RK, Kumar V, Tripathi DK, Sharma S. Nanomaterials and microbes' interactions: a contemporary overview. 3 Biotech 2019; 9:68. [PMID: 30729092 DOI: 10.1007/s13205-019-1576-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 01/12/2019] [Indexed: 12/17/2022] Open
Abstract
Use of nanomaterials in the field of science and technology includes different fields in food industry, medicine, agriculture and cosmetics. Nanoparticle-based sensors have wide range of applications in food industry for identification and detection of chemical contaminants, pathogenic bacteria, toxins and fungal toxins from food materials with high specificity and sensitivity. Nanoparticle-microbe interactions play a significant role in disease treatment in the form of antimicrobial agents. The inhibitory mechanism of nanoparticles against different bacteria and fungi includes release of metal ions that interacts with cellular components through various pathways including reactive oxygen species (ROS) generation, pore formation in cell membranes, cell wall damage, DNA damage, and cell cycle arrest and ultimately inhibits the growth of cells. Nanoparticle-based therapies are growing to study the therapeutic treatments of plant diseases and to prevent the growth of phytopathogens leading to the growing utilization of engineered nanomaterials. Hence, with this background, the present review focuses thoroughly on detailed actions and responses of nanomaterials against different bacteria and fungi as well as food sensing and storage.
Collapse
Affiliation(s)
- Jaspreet Singh
- 1Department of Biotechnology, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, Uttar Pradesh 211004 India
| | - Kanchan Vishwakarma
- 1Department of Biotechnology, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, Uttar Pradesh 211004 India
| | - Naleeni Ramawat
- 2Amity Institute of Organic Agriculture, Amity University Uttar Pradesh, I 2 Block, 5th Floor, AUUP Campus Sector-125, Noida, 201313 India
| | - Padmaja Rai
- 1Department of Biotechnology, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, Uttar Pradesh 211004 India
| | - Vivek Kumar Singh
- 3Department of Physics, Shri Mata Vaishno Devi University, Katra, Jammu And Kashmir 182320 India
| | - Rohit Kumar Mishra
- Department of Microbiology, Swami Vivekanand University, Sagar, Madhya Pradesh India
| | - Vivek Kumar
- 5Himalayan Institute of Biosciences, Swami Rama Himalayan University, Jolly Grant, Dehradun, India
| | - Durgesh Kumar Tripathi
- 2Amity Institute of Organic Agriculture, Amity University Uttar Pradesh, I 2 Block, 5th Floor, AUUP Campus Sector-125, Noida, 201313 India
| | - Shivesh Sharma
- 1Department of Biotechnology, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, Uttar Pradesh 211004 India
| |
Collapse
|