1
|
Shipp A, Torres WI. Ruptured Ectopic Pregnancy, Ovarian Torsion, Dermoid Cyst, Leiomyomata, and Endometriosis: A Case Report of a Pelvic Quintet. Cureus 2024; 16:e66884. [PMID: 39280523 PMCID: PMC11398850 DOI: 10.7759/cureus.66884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 08/12/2024] [Indexed: 09/18/2024] Open
Abstract
The chances of a female of reproductive age presenting with a ruptured ectopic pregnancy are relatively low. Ectopic pregnancies make up 1-2% of all pregnancies and 20% of ectopic ruptures. The chances of a patient with an ovarian torsion with a dermoid cyst are also low. The incidence of ovarian torsions is 2-5%, and a dermoid cyst is found in 25% of all ovarian torsions. The odds of a single patient presenting with both a ruptured ectopic pregnancy and ovarian torsion with a dermoid cyst, along with other pathologies, including fibroids and endometriosis, are exceptionally improbable but not impossible. We present a case of a 32-year-old gravida 1 para 0000 (G1P0) female who presented to the emergency department (ED) after five weeks of amenorrhea with light vaginal bleeding and severe left lower quadrant abdominal pain. A transvaginal ultrasound (TVUS) was performed and was questionable but unclear for an ectopic pregnancy. A diagnostic laparoscopy was indicated and confirmed the diagnoses of a left ruptured ectopic pregnancy with hemoperitoneum, right ovarian torsion with a right ovarian dermoid cyst, multiple subserosal leiomyomas, and endometriosis of the posterior cul-de-sac. Given the unclear TVUS results, the ultimate decision to perform a diagnostic laparoscopy was largely based on the patient's history and presenting symptoms. This case demonstrates a pelvic quintet, five rare pelvic anomalies, in a single patient who received a potentially lifesaving salpingectomy, right cystectomy, and right ovarian detorsion.
Collapse
Affiliation(s)
- Arianne Shipp
- Osteopathic Medicine, Nova Southeastern University Dr. Kiran C. Patel College of Osteopathic Medicine, Clearwater, USA
| | - Wanda I Torres
- Obstetrics and Gynecology, Nova Southeastern University Dr. Kiran C. Patel College of Osteopathic Medicine, Clearwater, USA
- Obstetrics and Gynecology, Suncoast Women's Care, Trinity, USA
| |
Collapse
|
2
|
Bradburn E, Conde-Agudelo A, Roberts NW, Villar J, Papageorghiou AT. Accuracy of prenatal and postnatal biomarkers for estimating gestational age: a systematic review and meta-analysis. EClinicalMedicine 2024; 70:102498. [PMID: 38495518 PMCID: PMC10940947 DOI: 10.1016/j.eclinm.2024.102498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/21/2024] [Accepted: 02/02/2024] [Indexed: 03/19/2024] Open
Abstract
Background Knowledge of gestational age (GA) is key in clinical management of individual obstetric patients, and critical to be able to calculate rates of preterm birth and small for GA at a population level. Currently, the gold standard for pregnancy dating is measurement of the fetal crown rump length at 11-14 weeks of gestation. However, this is not possible for women first presenting in later pregnancy, or in settings where routine ultrasound is not available. A reliable, cheap and easy to measure GA-dependent biomarker would provide an important breakthrough in estimating the age of pregnancy. Therefore, the aim of this study was to determine the accuracy of prenatal and postnatal biomarkers for estimating gestational age (GA). Methods Systematic review prospectively registered with PROSPERO (CRD42020167727) and reported in accordance with the PRISMA-DTA. Medline, Embase, CINAHL, LILACS, and other databases were searched from inception until September 2023 for cohort or cross-sectional studies that reported on the accuracy of prenatal and postnatal biomarkers for estimating GA. In addition, we searched Google Scholar and screened proceedings of relevant conferences and reference lists of identified studies and relevant reviews. There were no language or date restrictions. Pooled coefficients of correlation and root mean square error (RMSE, average deviation in weeks between the GA estimated by the biomarker and that estimated by the gold standard method) were calculated. The risk of bias in each included study was also assessed. Findings Thirty-nine studies fulfilled the inclusion criteria: 20 studies (2,050 women) assessed prenatal biomarkers (placental hormones, metabolomic profiles, proteomics, cell-free RNA transcripts, and exon-level gene expression), and 19 (1,738,652 newborns) assessed postnatal biomarkers (metabolomic profiles, DNA methylation profiles, and fetal haematological components). Among the prenatal biomarkers assessed, human chorionic gonadotrophin measured in maternal serum between 4 and 9 weeks of gestation showed the highest correlation with the reference standard GA, with a pooled coefficient of correlation of 0.88. Among the postnatal biomarkers assessed, metabolomic profiling from newborn blood spots provided the most accurate estimate of GA, with a pooled RMSE of 1.03 weeks across all GAs. It performed best for term infants with a slightly reduced accuracy for preterm or small for GA infants. The pooled RMSEs for metabolomic profiling and DNA methylation profile from cord blood samples were 1.57 and 1.60 weeks, respectively. Interpretation We identified no antenatal biomarkers that accurately predict GA over a wide window of pregnancy. Postnatally, metabolomic profiling from newborn blood spot provides an accurate estimate of GA, however, as this is known only after birth it is not useful to guide antenatal care. Further prenatal studies are needed to identify biomarkers that can be used in isolation, as part of a biomarker panel, or in combination with other clinical methods to narrow prediction intervals of GA estimation. Funding The research was funded by the Bill and Melinda Gates Foundation (INV-000368). ATP is supported by the Oxford Partnership Comprehensive Biomedical Research Centre with funding from the NIHR Biomedical Research Centre funding scheme. The views expressed are those of the authors and not necessarily those of the UK National Health Service, the NIHR, the Department of Health, or the Department of Biotechnology. The funders of this study had no role in study design, data collection, analysis or interpretation of the data, in writing the paper or the decision to submit for publication.
Collapse
Affiliation(s)
- Elizabeth Bradburn
- Nuffield Department of Women’s & Reproductive Health, University of Oxford, Oxford, UK
| | - Agustin Conde-Agudelo
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| | - Nia W. Roberts
- Bodleian Health Care Libraries, University of Oxford, Oxford, UK
| | - Jose Villar
- Nuffield Department of Women’s & Reproductive Health, University of Oxford, Oxford, UK
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| | - Aris T. Papageorghiou
- Nuffield Department of Women’s & Reproductive Health, University of Oxford, Oxford, UK
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| |
Collapse
|
3
|
Hussein SS, Qader MMA, Akram W. Prediction of Placenta Previa from Serial Reading of Serum Human Chorionic Gonadotropin Late in the First Half of Pregnancy. J Obstet Gynaecol India 2024; 74:27-30. [PMID: 38434132 PMCID: PMC10902246 DOI: 10.1007/s13224-023-01786-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 05/30/2023] [Indexed: 03/05/2024] Open
Abstract
Background Abnormally sited placenta is considered a major life-threatening condition for pregnant woman, and many debate about the way of early diagnosis and management to decrease the mortality and morbidity. Aim of Study To evaluate the role of beta-human chorionic gonadotrophin (B-HCG) level in the first half of pregnancy as a marker for prediction of placenta previa. Study Design This is a prospective study done in Al-Yarmouk Teaching Hospital from first of January 2020 till first of January 2021. Material and Methods A total of 57 patients have been recruited. For all participated women in this study were sampled between 14 and 18 weeks of gestational age for serum human chorionic gonadotropins measured in international units. Patients who developed placenta previa were diagnosed on the basis of development of vaginal bleeding either late in the second trimester or early in the second trimester. After developing vaginal bleeding, all patients were sent for routine ultrasound scan to confirm the presence of placenta previa. Result After recruiting a total of 57 women among which 14 patients were found to have placenta previa, ANOVA test shows a statistically significant difference between women with normal placenta and women with placenta previa P value < 0.001. Receiver operator characteristics curve was constructed to evaluate the optimum cutoff value for serum HCG between normal women and women with placenta previa sampled at 14-18 weeks of gestation. The optimum cutoff value is mean serum HCG > 105,380 IU in 14 weeks of gestation, and the sensitivity and specificity were calculated as 100% and 72.2%, respectively. Conclusion B-HCG level in first half of pregnancy can be used as a predictor marker for placenta previa.
Collapse
|
4
|
Srajer A, Wylie M, Zaver F, Lonergan K, Brain P, Lang E. Emergency physician gender is associated with early pregnancy loss management: a multisite retrospective cohort study. Emerg Med J 2023; 40:242-247. [PMID: 36868812 DOI: 10.1136/emermed-2021-212214] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 02/05/2023] [Indexed: 03/05/2023]
Abstract
BACKGROUND Patients experiencing early pregnancy loss often first present to the emergency department (ED) where they can be managed non-operatively through expectant or medical management, or surgically by the obstetrical team. Studies have reported that physician gender can influence clinical decision making, but there is limited research on this phenomenon in the ED. The objective of this study was to determine whether emergency physician gender is associated with early pregnancy loss management. METHODS Data were retrospectively collected from patients who presented to Calgary EDs with a non-viable pregnancy from 2014 to 2019. Pregnancies >12 weeks gestational age were excluded. The emergency physicians included saw at least 15 cases of pregnancy loss over the study period. The primary outcome was obstetrical consult rates by male versus female emergency physicians. Secondary outcomes included rates of initial surgical evacuation via dilation and curettage (D&C) procedures, ED returns, returns to care for D&Cs and total D&C rates. Data were analysed using χ2, Fisher's exact and Mann-Whitney U tests, as appropriate. Multivariable logistic regression models accounted for physician age, years of practice, training programme and type of pregnancy loss. RESULTS 98 emergency physicians and 2630 patients from 4 ED sites were included. 76.5% of the physicians were male accounting for 80.4% of pregnancy loss patients. Patients seen by female physicians were more likely to receive an obstetrical consultation (adjusted OR (aOR) 1.50, 95% CI 1.22 to 1.83) and initial surgical management (aOR 1.35, 95% CI 1.08 to 1.69). ED return rates and total D&C rates were not associated with physician gender. CONCLUSION Patients seen by female emergency physicians had higher rates of obstetrical consultation and initial operative management compared with those seen by male emergency physicians, but outcomes were similar. Additional research is required to determine why these gender differences exist and how these discrepancies may impact the care of early pregnancy loss patients.
Collapse
Affiliation(s)
- Amelia Srajer
- Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Megg Wylie
- Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Fareen Zaver
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada
| | | | - Philippa Brain
- Department of Obstetrics and Gynecology, University of Calgary, Calgary, Alberta, Canada
| | - Eddy Lang
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
5
|
Accuracy of serum human chorionic gonadotrophin for estimating gestational age in the first trimester of pregnancy: population-based study. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2023; 45:331-337. [PMID: 36924991 DOI: 10.1016/j.jogc.2023.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/20/2023] [Accepted: 02/21/2023] [Indexed: 03/18/2023]
Abstract
This study determined the accuracy of first trimester serum Human Chorionic Gonadotrophin (HCG) for estimating gestational age (GA). We included 273,584 singleton livebirths that had a first trimester ultrasound and measured serum HCG at 4-12 weeks gestation in XXX from 2012-2018. We estimated HCG accuracy compared to known GA, within a boundary of +/- 1 week. Between 4-8 weeks gestation, sensitivity of HCG was over 88%, and specificity over 51%. However, at 9-12 weeks, sensitivity declined from 72% to 0%, and specificity rose from 86% to 100%. At all GA, the Positive Predictive Value was consistently under 42%, while Negative Predictive Values were over 96%. Within epidemiological studies in which GA is otherwise unknown, first trimester serum HCG may aid somewhat in estimating GA between 4 to 6 weeks gestation, but much less so thereafter. Thus, there remains an ongoing need for an accurate method for estimating missing GA within large datasets.
Collapse
|
6
|
Schulte S, Huang J, Pierce NA. Hybridization Chain Reaction Lateral Flow Assays for Amplified Instrument-Free At-Home SARS-CoV-2 Testing. ACS Infect Dis 2023; 9:450-458. [PMID: 36735927 PMCID: PMC9924079 DOI: 10.1021/acsinfecdis.2c00472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Indexed: 02/05/2023]
Abstract
The lateral flow assay format enables rapid, instrument-free, at-home testing for SARS-CoV-2. Due to the absence of signal amplification, this simplicity comes at a cost in sensitivity. Here, we enhance sensitivity by developing an amplified lateral flow assay that incorporates isothermal, enzyme-free signal amplification based on the mechanism of hybridization chain reaction (HCR). The simplicity of the user experience is maintained using a disposable 3-channel lateral flow device to automatically deliver reagents to the test region in three successive stages without user interaction. To perform a test, the user loads the sample, closes the device, and reads the result by eye after 60 min. Detecting gamma-irradiated SARS-CoV-2 virions in a mixture of saliva and extraction buffer, the current amplified HCR lateral flow assay achieves a limit of detection of 200 copies/μL using available antibodies to target the SARS-CoV-2 nucleocapsid protein. By comparison, five commercial unamplified lateral flow assays that use proprietary antibodies exhibit limits of detection of 500 copies/μL, 1000 copies/μL, 2000 copies/μL, 2000 copies/μL, and 20,000 copies/μL. By swapping out antibody probes to target different pathogens, amplified HCR lateral flow assays offer a platform for simple, rapid, and sensitive at-home testing for infectious diseases. As an alternative to viral protein detection, we further introduce an HCR lateral flow assay for viral RNA detection.
Collapse
Affiliation(s)
- Samuel
J. Schulte
- Division
of Biology & Biological Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Jining Huang
- Division
of Biology & Biological Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Niles A. Pierce
- Division
of Biology & Biological Engineering, California Institute of Technology, Pasadena, California 91125, United States
- Division
of Engineering & Applied Science, California
Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
7
|
Shazly SA, Radwan AA, Abdo MS, Moustafa HY, Abd-Elkariem AY, Ali SS, Ahmed NB, Hosny EM, Abouzeid MH, Eltaweel NA, Hortu I, Abdelbadie AS, Fahmy MS, Attyia MI, Shawki AA, Said AE, Mohamed YI, Hemdan HN, Hemdan MN, Mohamed NG, Adam RI. Middle-East obgyn graduate education (MOGGE) foundation practice guidelines: diagnostic approach to pregnancy of unknown location: practice guideline no. 03-O-21. MIDDLE EAST FERTILITY SOCIETY JOURNAL 2022. [DOI: 10.1186/s43043-022-00114-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Pregnancy of unknown location (PUL) is a term used to describe failure of visualization of intrauterine or extrauterine gestational sac in a woman with a positive pregnancy test.
Body of the abstract
Ectopic pregnancy (EP) accounts for 1–2 % of all pregnancies. EP contributes to maternal mortality of a known cause by 4% in developed countries. However, case fatality rate may be 10 times higher in low-resource countries. This may be attributed to delayed diagnosis and lack of resources. PUL is a temporary term that may eventually lead to diagnosis of viable intrauterine pregnancy, pregnancy loss, or more seriously, EP.
Conclusion
This guideline appraises current evidence on assessment of PUL and early diagnosis of EP particularly in low-resource settings.
Collapse
|
8
|
Spontaneous Heterotopic Pregnancy: Diagnosis and Management. Case Rep Obstet Gynecol 2022; 2022:2994808. [PMID: 35928785 PMCID: PMC9345693 DOI: 10.1155/2022/2994808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 07/20/2022] [Indexed: 11/26/2022] Open
Abstract
Background Heterotopic pregnancies albeit rare are conceivably life-threatening if missed. With the development of assisted reproductive techniques, the incidence has increased. Confirmation of an intrauterine pregnancy (IUP) should not preclude the existence of a heterotopic pregnancy. Case A healthy 27-year-old patient (gravida 4, term 1, preterm 0, abortion 2, living 1) at approximately 5 weeks gestation through natural conception presented to the emergency room with acute abdominal pain and vaginal bleeding. Pelvic ultrasound showed evidence of an IUP and a right adnexal mass, raising suspicion for a heterotopic pregnancy. The patient underwent an uncomplicated laparoscopic right salpingectomy. An IUP was confirmed on ultrasound postoperatively. The patient had an early pregnancy loss at 8 weeks of gestation. Conclusion With a high index of suspicion from clinical presentation and pelvic imaging, heterotopic pregnancy, while rare, should not be ruled out.
Collapse
|
9
|
Sturgeon C, Butler SA, Gould F, Johnson S, Rowlands S, Stenman UH, Grenache DG. Recommendations for validation testing of home pregnancy tests (HPTs) in Europe. Clin Chem Lab Med 2021; 59:cclm-2020-1523. [PMID: 33544509 DOI: 10.1515/cclm-2020-1523] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 12/03/2020] [Indexed: 01/10/2023]
Abstract
Home pregnancy tests (HPTs) available in Europe include accuracy and other performance claims listed on their packaging. Due to the lack of guidance on the standardisation of such products, it is often difficult to replicate these claims when tested on a clinical sample, whether in a laboratory setting or by lay users. The In Vitro Diagnostic Regulation is a set of requirements that mandate comprehensive validation data on human pregnancy tests and other in vitro devices. It is due to replace the current European Directive (98/79/EC) and fully implemented in Europe by 2022. In June 2019, a panel of seven experts convened to discuss the validation studies required to provide the information needed to meet the new regulation for HPTs in Europe and proposed 15 recommendations for best practice. Defining best practice at all stages of validation of these important tests may ensure that tests marketed in Europe are fit for purpose, enabling lay users to be confident of the high quality of the HPT results they obtain. The panelists believe that the recommendations proposed here for the validation of HPTs may constructively contribute to improved standardisation of validation procedures in Europe.
Collapse
Affiliation(s)
- Catharine Sturgeon
- Department of Laboratory Medicine, UK National External Quality Assessment Service (UK NEQAS), Edinburgh, UK
| | | | | | - Sarah Johnson
- Clinical Affairs, SPD Development Company Limited, Bedford, UK
| | - Sam Rowlands
- Department of Medical Sciences & Public Health, Bournemouth University, Bournemouth, UK
| | - Ulf-Håkan Stenman
- Department of Clinical Chemistry and Haematology, University of Helsinki, Helsinki, Finland
| | | |
Collapse
|
10
|
Foo L, Johnson S, Marriott L, Bourne T, Bennett P, Lees C. Peri-implantation urinary hormone monitoring distinguishes between types of first-trimester spontaneous pregnancy loss. Paediatr Perinat Epidemiol 2020; 34:495-503. [PMID: 32056241 PMCID: PMC7496486 DOI: 10.1111/ppe.12613] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 09/17/2019] [Accepted: 10/27/2019] [Indexed: 01/14/2023]
Abstract
BACKGROUND Lutenising hormone (LH) and human chorionic gonadotropin (hCG) hormone are useful biochemical markers to indicate ovulation and embryonic implantation, respectively. We explored "point-of-care" LH and hCG testing using a digital home-testing device in a cohort trying to conceive. OBJECTIVE To determine conception and spontaneous pregnancy loss rates, and to assess whether trends in LH-hCG interval which are known to be associated with pregnancy viability could be identified with point-of-care testing. METHODS We recruited healthy women aged 18-44 planning a pregnancy. Participants used a home monitor to track LH and hCG levels for 12 menstrual cycles or until pregnancy was conceived. Pregnancy outcomes (viable, clinical miscarriage, or biochemical pregnancy loss) were recorded. Monitor data were analysed by a statistician blinded to pregnancy outcome. RESULTS From 387 recruits, there were 290 pregnancies with known outcomes within study timeline. Adequate monitor data for analysis were available for 150 conceptive cycles. Overall spontaneous first-trimester pregnancy loss rate was 30% with clinically recognised miscarriage rate of 17%. The difference to LH-hCG interval median had wider spread for biochemical losses (0.5-8.5 days) compared with clinical miscarriage (0-5 days) and viable pregnancies (0-6 days). Fixed effect hCG profile change distinguished between pregnancy outcomes from as early as day-2 post-hCG rise from baseline. CONCLUSIONS The risk of first-trimester spontaneous pregnancy loss in our prospective cohort is comparable to studies utilising daily urinary hCG collection and laboratory assays. A wider LH-hCG interval range is associated with biochemical pregnancy loss and may relate to late or early implantation. Although early hCG changes discriminate between pregnancies that will miscarry from viable pregnancies, this point-of-care testing model is not sufficiently developed to be predictive.
Collapse
Affiliation(s)
- Lin Foo
- Institute for Reproductive and Developmental BiologyImperial CollegeLondonUK
| | | | | | - Tom Bourne
- Institute for Reproductive and Developmental BiologyImperial CollegeLondonUK
| | - Phillip Bennett
- Institute for Reproductive and Developmental BiologyImperial CollegeLondonUK
| | - Christoph Lees
- Institute for Reproductive and Developmental BiologyImperial CollegeLondonUK
| |
Collapse
|
11
|
Xu L, Wei Q, Wu Q, Zhong Y, Li Y, Xu J, Zhu Y. Higher ꞵ-human chorionic gonadotropin and estrogen levels during the first 6 weeks of pregnancy are associated with threatened abortion. Biosci Trends 2019; 13:245-252. [PMID: 31130576 DOI: 10.5582/bst.2019.01111] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The associations of human chorionic gonadotropin (hCG), estrogen, and progesterone levels with threatened abortion have not been fully studied. Eighty women with threatened abortion were recruited sequentially, and the levels in their pregnancy hormones during the first trimester were compared with that of 160 normal early pregnancy controls. The natural logarithm transformed (Ln) hCG and Lnestrogen of women with threatened abortion and gestational age ≤ 6 weeks were significantly higher than values for the normal controls of the same gestational age (8.6 ± 1.2 vs. 7.4 ± 1.7 mIU/mL and 5.8 ± 0.4 vs. 5.4 ± 0.5 pg/mL); the two hormones reached similar levels in the groups of gestational age > 6 weeks. Among the group with gestational age ≤ 6 weeks, a univariate logistic regression showed that LnhCG and Lnestrogen were associated with threatened abortion, with odds ratios (ORs) of 1.85 [95% confidence interval (CI): 1.30-2.64] and 4.62 (95% CI: 1.67-12.80), respectively. The multivariate logistic regression model revealed that hCG and estrogen were mutually confounding factors, and only hCG was an independent factor for threatened abortion (OR 1.56; 95% CI: 1.06-2.28). None of the variables in the univariate or multivariate logistic regression was a factor associated with threatened abortion after 6 weeks gestational age. In conclusion, β-hCG and estrogen levels in the first half of the first trimester are factors associated with threatened abortion.
Collapse
Affiliation(s)
- Ling Xu
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| | - Qun Wei
- Songjiang Maternity & Child Health Hospital of Shanghai
| | - Qiong Wu
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| | - Yanbo Zhong
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| | - Yangfang Li
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| | - Jun Xu
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| | - Yunheng Zhu
- Department of Obstetrics and Gynecology, Minhang Hospital, Fudan University
| |
Collapse
|
12
|
Martinez_Brito D, Bueno_Fis E, Fiallo_Fernandez T, Torres_Castellanos M, Correa_Vidal MT, Montes De Oca_Porto R. “Application of the ultra micro analytical system (SUMA) technology for the detection of urinary hCG in antidoping control”. J Immunoassay Immunochem 2018; 39:672-686. [DOI: 10.1080/15321819.2018.1531020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
13
|
Maternal human chorionic gonadotrophin concentrations in very early pregnancy and risk of hyperemesis gravidarum: A retrospective cohort study of 4372 pregnancies after in vitro fertilization. Eur J Obstet Gynecol Reprod Biol 2018; 221:12-16. [DOI: 10.1016/j.ejogrb.2017.12.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 11/24/2017] [Accepted: 12/06/2017] [Indexed: 11/20/2022]
|
14
|
Haslam C, Damiati S, Whitley T, Davey P, Ifeachor E, Awan SA. Label-Free Sensors Based on Graphene Field-Effect Transistors for the Detection of Human Chorionic Gonadotropin Cancer Risk Biomarker. Diagnostics (Basel) 2018; 8:E5. [PMID: 29316718 PMCID: PMC5871988 DOI: 10.3390/diagnostics8010005] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 12/27/2017] [Accepted: 01/03/2018] [Indexed: 12/27/2022] Open
Abstract
We report on the development of label-free chemical vapour deposition (CVD) graphene field effect transistor (GFET) immunosensors for the sensitive detection of Human Chorionic Gonadotropin (hCG), a glycoprotein risk biomarker of certain cancers. The GFET sensors were fabricated on Si/SiO₂ substrate using photolithography with evaporated chromium and sputtered gold contacts. GFET channels were functionalised with a linker molecule to an immobile anti-hCG antibody on the surface of graphene. The binding reaction of the antibody with varying concentration levels of hCG antigen demonstrated the limit of detection of the GFET sensors to be below 1 pg/mL using four-probe electrical measurements. We also show that annealing can significantly improve the carrier transport properties of GFETs and shift the Dirac point (Fermi level) with reduced p-doping in back-gated measurements. The developed GFET biosensors are generic and could find applications in a broad range of medical diagnostics in addition to cancer, such as neurodegenerative (Alzheimer's and Parkinson's ) and cardiovascular disorders.
Collapse
Affiliation(s)
- Carrie Haslam
- Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK.
| | - Samar Damiati
- Department of Biochemistry, Faculty of Science, King Abdulaziz University (KAU), Jeddah 21589, Saudi Arabia.
| | - Toby Whitley
- Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK.
| | - Paul Davey
- Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK.
| | - Emmanuel Ifeachor
- Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK.
| | - Shakil A Awan
- Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK.
| |
Collapse
|
15
|
Mahendru AA, Wilhelm-Benartzi CS, Wilkinson IB, McEniery CM, Johnson S, Lees C. Gestational length assignment based on last menstrual period, first trimester crown-rump length, ovulation, and implantation timing. Arch Gynecol Obstet 2016; 294:867-76. [PMID: 27469987 PMCID: PMC5018029 DOI: 10.1007/s00404-016-4153-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 07/13/2016] [Indexed: 11/25/2022]
Abstract
PURPOSE Understanding the natural length of human pregnancy is central to clinical care. However, variability in the reference methods to assign gestational age (GA) confound our understanding of pregnancy length. Assignation from ultrasound measurement of fetal crown-rump length (CRL) has superseded that based on last menstrual period (LMP). Our aim was to estimate gestational length based on LMP, ultrasound CRL, and implantation that were known, compared to pregnancy duration assigned by day of ovulation. METHODS Prospective study in 143 women trying to conceive. In 71 ongoing pregnancies, gestational length was estimated from LMP, CRL at 10-14 weeks, ovulation, and implantation day. For each method of GA assignment, the distribution in observed gestational length was derived and both agreement and correlation between the methods determined. RESULTS Median ovulation and implantation days were 16 and 27, respectively. The gestational length based on LMP, CRL, implantation, and ovulation was similar: 279, 278, 276.5 and 276.5 days, respectively. The distributions for observed gestational length were widest where GA was assigned from CRL and LMP and narrowest when assigned from implantation and ovulation day. The strongest correlation for gestational length assessment was between ovulation and implantation (r = 0.98) and weakest between CRL and LMP (r = 0.88). CONCLUSIONS The most accurate method of predicting gestational length is ovulation day, and this agrees closely with implantation day. Prediction of gestational length from CRL and known LMP are both inferior to ovulation and implantation day. This information could have important implications on the routine assignment of gestational age.
Collapse
Affiliation(s)
- Amita A Mahendru
- Fetal Medicine Department, Nottingham University Hospitals NHS Trust, Nottingham, UK
- Department of Fetal Medicine, Addenbrooke's Hospital, Cambridge, CB2 2QQ, UK
| | | | - Ian B Wilkinson
- Division of Experimental Medicine and Immunotherapeutics, Addenbrooke's Hospital, University of Cambridge, Box 98, Cambridge, CB20QQ, UK
| | - Carmel M McEniery
- Division of Experimental Medicine and Immunotherapeutics, Addenbrooke's Hospital, University of Cambridge, Box 98, Cambridge, CB20QQ, UK
| | | | - Christoph Lees
- Department of Fetal Medicine, Addenbrooke's Hospital, Cambridge, CB2 2QQ, UK.
- Department of Surgery and Cancer, Institute of Developmental and Reproductive Biology, Imperial College London, London, W12 0HS, UK.
- Department of Development and Regeneration, University Hospitals Leuven, KU Leuven, Campus Gasthuisberg, 3000, Leuven, Belgium.
| |
Collapse
|
16
|
Dual-immuno-MS technique for improved differentiation power in heterodimeric protein biomarker analysis: determination and differentiation of human chorionic gonadotropin variants in serum. Anal Bioanal Chem 2016; 408:7379-91. [DOI: 10.1007/s00216-016-9818-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 07/07/2016] [Accepted: 07/20/2016] [Indexed: 02/06/2023]
|
17
|
Reference ranges and determinants of total hCG levels during pregnancy: the Generation R Study. Eur J Epidemiol 2015; 30:1057-66. [PMID: 25963653 PMCID: PMC4584104 DOI: 10.1007/s10654-015-0039-0] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Accepted: 05/04/2015] [Indexed: 01/01/2023]
Abstract
Human chorionic gonadotropin (hCG) is a pregnancy hormone secreted by the placental synctiotrophoblast cell layer that has been linked to fetal growth and various placental, uterine and fetal functions. In order to investigate the effects of hCG on clinical endpoints, knowledge on reference range (RR) methodology and determinants of gestational hCG levels is crucial. Moreover, a better understanding of gestational hCG physiology can improve current screening programs and future clinical management. Serum total hCG levels were determined in 8195 women participating in the Generation R Study. Gestational age specific RRs using ‘ultrasound derived gestational age’ (US RRs) were calculated and compared with ‘last menstrual period derived gestational age’ (LMP RRs) and a model-based RR. We also investigated which pregnancy characteristics were associated with hCG levels. Compared to the US RRs, the LMP RRs were lower, most notably for the median and lower limit levels. No considerable differences were found between RRs calculated in the general population or in uncomplicated pregnancies only. Maternal smoking, BMI, parity, ethnicity, fetal gender, placental weight and hyperemesis gravidarum symptoms were associated with total hCG. We provide gestational RRs for total hCG and show that total hCG values and RR cut-offs during pregnancy vary depending on pregnancy dating methodology. This is likely due to the influence of hCG on embryonic growth, suggesting that ultrasound based pregnancy dating might be less reliable in women with high/low hCG levels. Furthermore, we identify different pregnancy characteristics that influence total hCG levels considerably and should therefore be accounted for in clinical studies.
Collapse
|
18
|
Gnoth C, Johnson S. Strips of Hope: Accuracy of Home Pregnancy Tests and New Developments. Geburtshilfe Frauenheilkd 2014; 74:661-669. [PMID: 25100881 DOI: 10.1055/s-0034-1368589] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 05/01/2014] [Accepted: 05/20/2014] [Indexed: 12/27/2022] Open
Abstract
The first home pregnancy test was introduced in 1976. Since then, pregnancy tests have become the most common diagnostic assay used at home. Pregnancy tests use antibodies to detect human chorionic gonadotropin (hCG). It is an ideal marker of pregnancy since it rises rapidly and consistently in early pregnancy and can be detected in urine. The most advanced home pregnancy test currently available assesses the level of hCG found in urine and claims to provide women with reliable results within just a few weeks of pregnancy. Today, over 15 different types of home pregnancy test are available to buy over the counter in Germany. Many tests claim to be highly accurate and capable of detecting pregnancy before the next monthly period is due, although claims such as 8 days prior to menstruation are unrealistic. However, users and healthcare professionals should be aware that, although all are labelled as CE, there are currently no standard criteria for testing performance and claims. This review provides an overview of the development of home pregnancy tests and the data on their efficacy together with an analysis of published data on the accuracy of hCG for the detection of early pregnancy and studies on the use of home-based pregnancy tests. Preliminary data on some home pregnancy tests available in Germany are presented which indicate that many results do not match the claims made in the package insert. Healthcare professionals and women should be aware that some of the claims made for home pregnancy tests are inconsistent and that common definitions and testing criteria are urgently needed.
Collapse
Affiliation(s)
- C Gnoth
- green-ivf, Grevenbroich, Germany ; Department of Gynecology and Obstetrics, University of Cologne, Cologne, Germany
| | - S Johnson
- SPD Development Company Ltd., Bedford, United Kingdom
| |
Collapse
|