1
|
Knight G, Mushambi M. Anesthetic challenges of pregnant obesity women. Best Pract Res Clin Obstet Gynaecol 2023; 91:102405. [PMID: 37688846 DOI: 10.1016/j.bpobgyn.2023.102405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/24/2023] [Accepted: 08/06/2023] [Indexed: 09/11/2023]
Abstract
Obesity causes significant morbidity and increases the mortality risk for both mother and fetus. With an increasing projected prevalence, it is vital that the obstetric anesthetist is equipped with the knowledge and tools to manage these women. A multi-disciplinary team approach and early planning is required. Neuraxial analgesia for labor helps to negate the need for general anesthesia, which is associated with increased risk in this subset of women. Catheter techniques for neuraxial anesthesia allow for titration, manipulation, and prolongation of the anesthetic block to reduce the risk of conversion to general anesthesia.
Collapse
Affiliation(s)
- Georgia Knight
- University Hospitals of Leicester, Infirmary Square, Leicester 0300 3031573, UK.
| | | |
Collapse
|
2
|
Ellis R, Laviola M, Stolady D, Valentine RL, Pillai A, Hardman JG. Comparison of apnoeic oxygen techniques in term pregnant subjects: a computational modelling study. Response to Br J Anaesth 2022; 129: 581-7. Br J Anaesth 2023; 130:e429-e430. [PMID: 36754707 DOI: 10.1016/j.bja.2023.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 01/07/2023] [Indexed: 02/10/2023] Open
Affiliation(s)
- Reena Ellis
- Nottingham University Hospitals NHS Trust, Nottingham, UK.
| | - Marianna Laviola
- Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| | - Daniel Stolady
- Anaesthesia, Queen Elizabeth Hospital King's Lynn NHS Foundation Trust, King's Lynn, UK
| | - Rebecca L Valentine
- Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| | - Arani Pillai
- Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Jonathan G Hardman
- Nottingham University Hospitals NHS Trust, Nottingham, UK; Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| |
Collapse
|
3
|
Lyons C. Comparison of apnoeic oxygen techniques in term pregnant subjects: a computational modelling study. Comment on Br J Anaesth 2022; 129: 581-7. Br J Anaesth 2023; 130:e24-e25. [PMID: 36462941 DOI: 10.1016/j.bja.2022.10.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 10/15/2022] [Accepted: 10/16/2022] [Indexed: 12/05/2022] Open
Affiliation(s)
- Craig Lyons
- Department of Anaesthesia, Great Ormond Street Hospital for Children, London, UK.
| |
Collapse
|
4
|
Mushambi MC, Kinsella SM. Hypoxaemia during induction of general anaesthesia in pregnant women – a surrogate for overall airway difficulty? SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA 2022. [DOI: 10.36303/sajaa.2022.28.5.2859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- MC Mushambi
- Leicester Medical School, University of Leicester,
United Kingdom
| | - SM Kinsella
- Department of Anaesthesia, St Michael’s Hospital,
United Kingdom
| |
Collapse
|
5
|
Ellis R, Laviola M, Stolady D, Valentine RL, Pillai A, Hardman JG. Comparison of apnoeic oxygen techniques in term pregnant subjects: a computational modelling study. Br J Anaesth 2022; 129:581-587. [PMID: 35963819 DOI: 10.1016/j.bja.2022.06.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 06/07/2022] [Accepted: 06/09/2022] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Hypoxaemia during general anaesthesia can cause harm. Apnoeic oxygenation extends safe apnoea time, reducing risk during airway management. We hypothesised that low-flow nasal oxygenation (LFNO) would extend safe apnoea time similarly to high-flow nasal oxygenation (HFNO), whilst allowing face-mask preoxygenation and rescue. METHODS A high-fidelity, computational, physiological model was used to examine the progression of hypoxaemia during apnoea in virtual models of pregnant women in and out of labour, with BMI of 24-50 kg m-2. Subjects were preoxygenated with oxygen 100% to reach end-tidal oxygen fraction (FE'O2) of 60%, 70%, 80%, or 90%. When apnoea started, HFNO or LFNO was commenced. To simulate varying degrees of effectiveness of LFNO, periglottic oxygen fraction (FgO2) of 21%, 60%, or 100% was configured. HFNO provided FgO2 100% and oscillating positive pharyngeal pressure. RESULTS Application of LFNO (FgO2 100%) after optimal preoxygenation (FE'O2 90%) resulted in similar or longer safe apnoea times than HFNO FE'O2 80% in all subjects in labour. For BMI of 24, the time to reach SaO2 90% with LFNO was 25.4 min (FE'O2 90%/FgO2 100%) vs 25.4 min with HFNO (FE'O2 80%). For BMI of 50, the time was 9.9 min with LFNO (FE'O2 90%/FgO2 100%) vs 4.3 min with HFNO (FE'O2 80%). A similar finding was seen in subjects with BMI ≥40 kg m-2 not in labour. CONCLUSIONS There is likely to be clinical benefit to using LFNO, given that LFNO and HFNO extend safe apnoea time similarly, particularly when BMI ≥40 kg m-2. Additional benefits to LFNO include the facilitation of rescue face-mask ventilation and ability to monitor FE'O2 during preoxygenation.
Collapse
Affiliation(s)
- Reena Ellis
- Nottingham University Hospitals NHS Trust, Nottingham, UK.
| | - Marianna Laviola
- Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| | - Daniel Stolady
- Anaesthesia, Queen Elizabeth Hospital King's Lynn NHS Foundation Hospital, King's Lynn, UK
| | - Rebecca L Valentine
- Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| | - Arani Pillai
- Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Jonathan G Hardman
- Nottingham University Hospitals NHS Trust, Nottingham, UK; Anaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK
| |
Collapse
|
6
|
Prior CH, Burlinson CEG, Chau A. Emergencies in obstetric anaesthesia: a narrative review. Anaesthesia 2022; 77:1416-1429. [PMID: 36089883 DOI: 10.1111/anae.15839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/18/2022] [Indexed: 11/28/2022]
Abstract
We conducted a narrative review in six areas of obstetric emergencies: category-1 caesarean section; difficult and failed airway; massive obstetric haemorrhage; hypertensive crisis; emergencies related to neuraxial anaesthesia; and maternal cardiac arrest. These areas represent significant research published within the last five years, with emphasis on large multicentre randomised trials, national or international practice guidelines and recommendations from major professional societies. Key topics discussed: prevention and management of failed neuraxial technique; role of high-flow nasal oxygenation and choice of neuromuscular drug in obstetric patients; prevention of accidental awareness during general anaesthesia; management of the difficult and failed obstetric airway; current perspectives on the use of tranexamic acid, fibrinogen concentrate and cell salvage; guidance on neuraxial placement in a thrombocytopenic obstetric patient; management of neuraxial drug errors, local anaesthetic systemic toxicity and unusually prolonged neuraxial block regression; and extracorporeal membrane oxygenation use in maternal cardiac arrest.
Collapse
Affiliation(s)
- C H Prior
- Department of Anaesthesia, West Middlesex University Hospital, London, UK
| | - C E G Burlinson
- Department of Anesthesia, BC Women's Hospital, Vancouver, BC, Canada.,Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada
| | - A Chau
- Department of Anesthesia, BC Women's Hospital, Vancouver, BC, Canada.,Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada.,Department of Anesthesia, St. Paul's Hospital, Vancouver, BC, Canada
| |
Collapse
|
7
|
Peri-intubation oxygenation for Caesarean delivery: is there an optimal technique? Br J Anaesth 2022; 129:468-471. [PMID: 35985842 DOI: 10.1016/j.bja.2022.07.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 07/13/2022] [Indexed: 11/21/2022] Open
Abstract
Peri-intubation oxygen administration to the pregnant patient during induction of general anaesthesia is critical to avoiding hypoxaemia and harm to the mother and fetus. Recent modelling comparing low-flow with high-flow nasal oxygen in simulated term pregnant women of varying body habitus, taken together with previous work, suggests that face mask preoxygenation with the use of low-flow or high-flow nasal oxygen during the period of apnoea prolongs the safe apnoea period, with the benefit varying by body habitus. Low-flow compared with high-flow nasal oxygen may be easier to combine with face mask preoxygenation and is readily available in all operating theatres, although future improvements in high-flow nasal oxygen delivery systems may improve ease of use for this indication.
Collapse
|
8
|
Singh A, Dhir A, Jain K, Trikha A. Role of high flow nasal cannula (HFNC) for pre-oxygenation among pregnant patients: Current evidence and review of literature. JOURNAL OF OBSTETRIC ANAESTHESIA AND CRITICAL CARE 2022. [DOI: 10.4103/joacc.joacc_18_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
9
|
Patel A, El-Boghdadly K. Facemask or high-flow nasal oxygenation: time to switch? Anaesthesia 2021; 77:7-11. [PMID: 34634137 DOI: 10.1111/anae.15593] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/06/2021] [Indexed: 01/13/2023]
Affiliation(s)
- A Patel
- Department of Anaesthesia, University College London Hospitals NHS Foundation Trust, London, UK
| | - K El-Boghdadly
- Department of Anaesthesia and Peri-operative Medicine, Guy's and St Thomas' NHS Foundation Trust, London, UK.,King's College London, London, UK
| |
Collapse
|
10
|
General anesthesia in the parturient. Int Anesthesiol Clin 2021; 59:78-89. [PMID: 34029247 DOI: 10.1097/aia.0000000000000327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Stolady D, Laviola M, Pillai A, Hardman JG. Effect of variable pre-oxygenation endpoints on safe apnoea time using high flow nasal oxygen for women in labour: a modelling investigation. Br J Anaesth 2021; 126:889-895. [PMID: 33549319 DOI: 10.1016/j.bja.2020.12.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 12/23/2020] [Accepted: 12/27/2020] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Studies of pulmonary denitrogenation (pre-oxygenation) in obstetric populations have shown high flow nasal oxygen therapy (HFNO) is inferior to facemask techniques. HFNO achieves median end-tidal oxygen fraction (FE'O2) of 0.87 after 3 min. As HFNO prolongs safe apnoea times through apnoeic oxygenation, we postulated that HFNO would still extend safe apnoeic times despite the lower FE'O2 after pre-oxygenation. METHODS The Interdisciplinary Collaboration in Systems Medicine simulation suite, a highly integrated, high-fidelity model of the human respiratory and cardiovascular systems, was used to study the effect of varying FE'O2 (60%, 70%, 80%, and 90%) on the duration of safe apnoea times using HFNO and facemask techniques (with the airway open and obstructed). The study population consisted of validated models of pregnant women in active labour and not in labour with BMI of 24, 35, 40, 45, and 50 kg m-2. RESULTS HFNO provided longer safe apnoeic times in all models, with all FE'O2 values. Labour and increased BMI reduced this effect, in particular a BMI of 50 kg m-2 reduced the improvement in apnoea time to 1.8-8.5 min (depending on the FE'O2), compared with an improvement of more than 60 min in the subject with BMI 24 kg m-2. CONCLUSIONS Despite generating lower FE'O2, HFNO provides longer safe apnoea times in pregnant subjects in labour. Care should be taken when used in patients with BMI ≥50 kg m-2 as the extension of the safe apnoea time is limited.
Collapse
Affiliation(s)
- Daniel Stolady
- Anaesthesia Queen Elizabeth Hospital King's Lynn NHS Foundation Hospital, Kings Lynn, UK.
| | - Marianna Laviola
- Anaesthesia and Critical Care, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham, UK
| | - Arani Pillai
- Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Jonathan G Hardman
- Anaesthesia and Critical Care, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham, UK; Nottingham University Hospitals NHS Trust, Nottingham, UK
| |
Collapse
|
12
|
Murphy NE, Coursin DB, Pryde P. Efficacy vs efficiency using high flow nasal oxygen in peri-intubation oxygenation of gravid women. Int J Obstet Anesth 2020; 45:17-20. [PMID: 33199258 DOI: 10.1016/j.ijoa.2020.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/13/2020] [Accepted: 10/10/2020] [Indexed: 12/20/2022]
Affiliation(s)
- N E Murphy
- Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health Madison, WI USA.
| | - D B Coursin
- Departments of Anesthesiology & Medicine, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - P Pryde
- Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health Madison, WI USA
| |
Collapse
|