1
|
Roy SK, Das P, Mondal A, Mandal A, Kuotsu K. Design, formulation and evaluation of multiparticulate time programmed system of ramipril for pulsed release: An approach in the management of early morning surge in blood pressure. J Drug Deliv Sci Technol 2021. [DOI: 10.1016/j.jddst.2021.102344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
2
|
Design and development of an innovative water insoluble film-coating combination for oral pulsatile drug delivery. J Drug Deliv Sci Technol 2018. [DOI: 10.1016/j.jddst.2017.10.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
3
|
Yang Y, Fang J, Shen L, Shan W. Simulation and evaluation of rupturable coated capsules by finite element method. Int J Pharm 2017; 519:220-229. [DOI: 10.1016/j.ijpharm.2017.01.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 12/30/2016] [Accepted: 01/12/2017] [Indexed: 11/28/2022]
|
4
|
Eo MY, Fan H, Cho YJ, Kim SM, Lee SK. Cellulose membrane as a biomaterial: from hydrolysis to depolymerization with electron beam. Biomater Res 2016; 20:16. [PMID: 27418974 PMCID: PMC4944233 DOI: 10.1186/s40824-016-0065-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 06/02/2016] [Indexed: 11/24/2022] Open
Abstract
The cellulose membrane (CM) is a major component of plant cell walls and is both a chemically and mechanically stable synthetic polymer with many applications for use in tissue engineering. However, due to its dissolution difficulty, there are no known physiologically relevant or pharmaceutically clinical applications for this polymer. Thus, research is underway on controlled and adjusted forms of cellulose depolymerization. To advance the study of applying CM for tissue engineering, we have suggested new possibilities for electron beam (E-beam) treatment of CM. Treatment of CM with an E-beam can modify physical, chemical, molecular and biological properties, so it can be studied continuously to improve its usefulness and to enhance value. We review clinical applications of CM, cellulose binding domains, cellulose crosslinking proteins, conventional hydrolysis of cellulose, and depolymerization with radiation and focus our experiences with depolymerization of E-beam irradiated CM in this article.
Collapse
Affiliation(s)
- Mi Young Eo
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, 110-768 South Korea
| | - Huan Fan
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, 110-768 South Korea
| | - Yun Ju Cho
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, 110-768 South Korea
| | - Soung Min Kim
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, 110-768 South Korea
| | - Suk Keun Lee
- Department of Oral Pathology, College of Dentistry, Gangneung-Wonju National University, Gangneung, 123 Chibyon-dong, Gangneung, 210-702 South Korea
| |
Collapse
|
5
|
Yang Y, Li J, Miao KS, Shan WG, Tang L, Yu HN. Simulation and evaluation of tablet-coating burst based on finite element method. Drug Dev Ind Pharm 2016; 42:1384-92. [DOI: 10.3109/03639045.2015.1137304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
6
|
Cao Z, Xu C, Ding X, Zhu S, Chen H, Qi D. Synthesis of fragrance/silica nanocapsules through a sol–gel process in miniemulsions and their application as aromatic finishing agents. Colloid Polym Sci 2015. [DOI: 10.1007/s00396-015-3502-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
7
|
Gangwar G, Kumar A, Pathak K. Utilizing Guar Gum for Development of “Tabs In Cap’ System of Losartan Potassium for Chronotherapeutics. Int J Biol Macromol 2015; 72:812-8. [DOI: 10.1016/j.ijbiomac.2014.09.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Accepted: 09/22/2014] [Indexed: 10/24/2022]
|
8
|
Xia Y, Pack DW. Pulsatile protein release from monodisperse liquid-core microcapsules of controllable shell thickness. Pharm Res 2014; 31:3201-10. [PMID: 24831313 DOI: 10.1007/s11095-014-1412-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2014] [Accepted: 05/06/2014] [Indexed: 11/29/2022]
Abstract
PURPOSE Pulsatile delivery of proteins, in which release occurs over a short time after a period of little or no release, is desirable for many applications. This paper investigates the effect of biodegradable polymer shell thickness on pulsatile protein release from biodegradable polymer microcapsules. METHODS Using precision particle fabrication (PPF) technology, monodisperse microcapsules were fabricated encapsulating bovine serum albumin (BSA) in a liquid core surrounded by a drug-free poly(lactide-co-glycolide) (PLG) shell of uniform, controlled thickness from 14 to 19 μm. RESULTS When using high molecular weight PLG (Mw 88 kDa), microparticles exhibited the desired core-shell structure with high BSA loading and encapsulation efficiency (55-65%). These particles exhibited very slow release of BSA for several weeks followed by rapid release of 80-90% of the encapsulated BSA within 7 days. Importantly, with increasing shell thickness the starting time of the pulsatile release could be controlled from 25 to 35 days. CONCLUSIONS Biodegradable polymer microcapsules with precisely controlled shell thickness provide pulsatile release with enhanced control of release profiles.
Collapse
Affiliation(s)
- Yujie Xia
- Department of Chemical and Biomolecular Engineering, University of Illinois, 600 S. Mathews Avenue, Urbana, Illinois, 61801, USA
| | | |
Collapse
|
9
|
Zhang Z, Qi X, Li X, Xing J, Zhu X, Wu Z. A novel pulsatile drug delivery system based on the physiochemical reaction between acrylic copolymer and organic acid: in vitro and in vivo evaluation. Int J Pharm 2013; 462:66-73. [PMID: 24368107 DOI: 10.1016/j.ijpharm.2013.12.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 11/18/2013] [Accepted: 12/15/2013] [Indexed: 10/25/2022]
Abstract
Multilayer-coating technology is the traditional method to achieve pulsatile drug release with the drawbacks of time consuming, more materials demanding and lack of efficiency. The purpose of this study was to design a novel pulsatile drug delivery system based on the physiochemical interaction between acrylic copolymer and organic acid with relatively simpler formulation and manufacturing process. The Enalapril Maleate (EM) pulsatile release pellets were prepared using extruding granulation, spheronization and fluid-bed coating technology. The ion-exchange experiment, hydration study and determination of glass transition temperature were conducted to explore the related drug release mechanism. Bioavailability experiment was carried out by administering the pulsatile release pellets to rats compared with marketed rapid release tablets Yisu. An obvious 4h lag time period and rapid drug release was observed from in vitro dissolution profiles. The release mechanism was a combination of both disassociated and undisassociated forms of succinic acid physiochemically interacting with Eudragit RS. The AUC0-τ of the EM pulsatile pellets and the market tablets was 702.384 ± 96.89 1 hn g/mL and 810.817 ± 67.712 h ng/mL, while the relative bioavailability was 86.62%. These studies demonstrate this novel pulsatile release concept may be a promising strategy for oral pulsatile delivery system.
Collapse
Affiliation(s)
- Ziwei Zhang
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China
| | - Xiaole Qi
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China
| | - Xiangbo Li
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China
| | - Jiayu Xing
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China
| | - Xuehua Zhu
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China
| | - Zhenghong Wu
- Key Laboratory of Modern Chinese Medicines, China Pharmaceutical University, Nanjing 210009, PR China; Yangtze River Pharmaceutical Group, State Key Laboratory for Advanced Formulation Technologies, Taizhou, PR China.
| |
Collapse
|
10
|
Robitaille M, Shi J, McBride S, Wan KT. Mechanical performance of hydrogel contact lenses with a range of power under parallel plate compression and central load. J Mech Behav Biomed Mater 2013; 22:59-64. [PMID: 23583634 DOI: 10.1016/j.jmbbm.2013.03.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Accepted: 03/11/2013] [Indexed: 11/30/2022]
Abstract
When a contact lens is compressed between two parallel plates (PPC) or under a central load (CLC), the constitutive relation depends not only on the mechanical properties such as elastic modulus, E, of the hydrogel materials, but also the lens power, d, or thickness variation, h(ϕ0), along the meridional direction ϕ0. Hyperopic lenses (d>0) are thicker at the apex along the optical axis and thin out gradually along the meridian, while myopic lenses (d<0) are thinnest at the apex. Mechanical deformation is quantified by the inter-relationship between applied force, F, vertical displacement of the external load, w0, contact or dimple radius, a, and the deformed profile, w(r). Force responses show that lenses with positive d are apparently stiffer in the initial loading but become more compliant as load increases. Conversely, lenses with negative d are more deformable initially and becomes gradually more resistant to loading. This is consistent with the theoretical shell model using the same E. The mechanical behavior has significant impacts in defining the degree of comfort of contact lenses as well as the lens adhesion to the corneal epithelium.
Collapse
Affiliation(s)
- Michael Robitaille
- Bioengineering, Northeastern University, Boston, MA 02115, United States
| | | | | | | |
Collapse
|
11
|
Maroni A, Zema L, Loreti G, Palugan L, Gazzaniga A. Film coatings for oral pulsatile release. Int J Pharm 2013; 457:362-71. [PMID: 23506956 DOI: 10.1016/j.ijpharm.2013.03.010] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Revised: 03/06/2013] [Accepted: 03/10/2013] [Indexed: 11/26/2022]
Abstract
Pulsatile delivery is generally intended as a release of the active ingredient that is delayed for a programmable period of time to meet particular chronotherapeutic needs and, in the case of oral administration, also target distal intestinal regions, such as the colon. Most oral pulsatile delivery platforms consist in coated formulations wherein the applied polymer serves as the release-controlling agent. When exposed to aqueous media, the coating initially performs as a protective barrier and, subsequently, undergoes a timely failure based on diverse mechanisms depending on its physico-chemical and formulation characteristics. Indeed, it may be ruptured because of the gradual expansion of the core, swell and/or erode due to the glassy-rubbery polymer transition or become permeable thus allowing the drug molecules to diffuse outwards. Otherwise, when the coating is a semipermeable membrane provided with one or more orifices, the drug is released through the latter as a result of an osmotic water influx. The vast majority of pulsatile delivery systems described so far have been prepared by spray-coating, which offers important versatility and feasibility advantages over other techniques such as press- and dip-coating. In the present article, the design, manufacturing and performance of spray-coated pulsatile delivery platforms is thus reviewed.
Collapse
Affiliation(s)
- Alessandra Maroni
- Università degli Studi di Milano, Dipartimento di Scienze Farmaceutiche, Sezione di Tecnologia e Legislazione Farmaceutiche "Maria Edvige Sangalli", Via G. Colombo 71, 20133 Milan, Italy
| | | | | | | | | |
Collapse
|
12
|
On-off pulsed oral drug-delivery systems: a possible tool for drug delivery in chronotherapy. Ther Deliv 2012; 2:1199-214. [PMID: 22833913 DOI: 10.4155/tde.11.91] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Circadian rhythms regulate most body functions and are important factors to consider when administering drugs. The existence of circadian rhythms in nature and their influences on human biological systems have given rise to the concept of chronotherapy, which is the science of delivering drugs in a synchronized manner with the rhythm-dependent circadian variation inherent in the human body. The safety and efficacy of a drug can be improved by matching the peak plasma concentration during a 24 h period of the rhythms. An on-off pulsed (pulsatile or time-controlled) release drug-delivery system offers rapid and transient release; stepwise release; and the sustained release of a certain amount of drug within a short time period after a predetermined off-release period according to the circadian rhythm of disease states. These systems deliver the drug at the right time and at an appropriate dosage and are the best approach for chronotherapy. These systems show promise for the optimal therapy of chronic diseases such as asthma, hypertension, myocardial infarction and arthritis, which show a circadian dependency. Various technologies have been adopted to mimic circadian rhythms in physiological functions and diseases. This review focuses on the basic concept of circadian rhythm, chronotherapy and recent advances in the development of on-off pulsed oral drug-delivery systems for optimal therapy.
Collapse
|
13
|
Maroni A, Zema L, Del Curto MD, Foppoli A, Gazzaniga A. Oral colon delivery of insulin with the aid of functional adjuvants. Adv Drug Deliv Rev 2012; 64:540-56. [PMID: 22086142 DOI: 10.1016/j.addr.2011.10.006] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Revised: 09/30/2011] [Accepted: 10/27/2011] [Indexed: 12/11/2022]
Abstract
Oral colon delivery is currently considered of importance not only for the treatment of local pathologies, such as primarily inflammatory bowel disease (IBD), but also as a means of accomplishing systemic therapeutic goals. Although the large bowel fails to be ideally suited for absorption processes, it may indeed offer a number of advantages over the small intestine, including a long transit time, lower levels of peptidases and higher responsiveness to permeation enhancers. Accordingly, it has been under extensive investigation as a possible strategy to improve the oral bioavailability of peptide and protein drugs. Because of a strong underlying rationale, most of these studies have focused on insulin. In the present review, the impact of key anatomical and physiological characteristics of the colon on its viability as a protein release site is discussed. Moreover, the main formulation approaches to oral colon targeting are outlined along with the design features and performance of insulin-based devices.
Collapse
|
14
|
Dual coating of swellable and rupturable polymers on Glipizide loaded MCC pellets for pulsatile delivery: Formulation design and in vitro evaluation. Int J Pharm 2011; 419:121-30. [DOI: 10.1016/j.ijpharm.2011.07.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2011] [Revised: 07/15/2011] [Accepted: 07/18/2011] [Indexed: 11/29/2022]
|
15
|
Bruce HF, Sheskey PJ, Garcia-Todd P, Felton LA. Novel low-molecular-weight hypromellose polymeric films for aqueous film coating applications. Drug Dev Ind Pharm 2011; 37:1439-45. [DOI: 10.3109/03639045.2011.584194] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
16
|
Pulsatile multiparticulate drug delivery system for metoprolol succinate. Arch Pharm Res 2011; 34:369-76. [DOI: 10.1007/s12272-011-0303-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Revised: 06/18/2010] [Accepted: 07/16/2010] [Indexed: 11/26/2022]
|
17
|
Oral pulsatile delivery: Rationale and chronopharmaceutical formulations. Int J Pharm 2010; 398:1-8. [DOI: 10.1016/j.ijpharm.2010.07.026] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2010] [Revised: 07/15/2010] [Accepted: 07/17/2010] [Indexed: 12/30/2022]
|
18
|
Efentakis M, Iliopoyloy A, Siamidi A. Effect of core size and excipients on the lag time and drug release from a pulsatile drug delivery system. Drug Dev Ind Pharm 2010; 37:113-20. [DOI: 10.3109/03639045.2010.495753] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
19
|
Sher P, Ingavle G, Ponrathnam S, Benson JR, Li NH, Pawar AP. Novel/conceptual floating pulsatile system using high internal phase emulsion based porous material intended for chronotherapy. AAPS PharmSciTech 2009; 10:1368-80. [PMID: 19936939 DOI: 10.1208/s12249-009-9331-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2009] [Accepted: 10/13/2009] [Indexed: 11/30/2022] Open
Abstract
The aim of the present study was to design a novel/conceptual delivery system using ibuprofen, anticipated for chronotherapy in arthritis with porous material to overcome the formulation limits (multiple steps, polymers, excipients) and to optimize drug loading for a desired release profile suitable for in vitro investigations. The objective of this delivery system lies in the availability of maximum drug amount for absorption in the wee hours as recommended. Drug loading using 3(2) factorial design on porous carrier, synthesized by high internal phase emulsion technique using styrene and divinylbenzene, was done via solvent evaporation using methanol and dichloromethane. The system was evaluated in vitro for drug loading, encapsulation efficiency, and surface characterization by scanning electron, atomic force microscopy, and customized drug release study. This study examined critical parameters such as solvent volume, drug amount, and solvent polarity on investigations related to drug adsorption and release mostly favoring low-polarity solvent dichloromethane. Overall release in all batches ranged 0.98-52% in acidic medium and 71-94% in basic medium. These results exhibit uniqueness in achieving the least drug release of 0.98%, an ideal one, without using any release modifiers, making it distinct from other approaches/technologies for time and controlled release and for chronotherapy.
Collapse
|
20
|
Ghosh S, Roy G, Mukherjee B. Dental mold: a novel formulation to treat common dental disorders. AAPS PharmSciTech 2009; 10:692-702. [PMID: 19466555 DOI: 10.1208/s12249-009-9255-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2009] [Accepted: 04/30/2009] [Indexed: 11/30/2022] Open
Abstract
Oral administration of antibiotics to treat dental problems mostly yields slow actions due to slow onset and hepatic "first-pass." Again, commonly used dental paints are generally washed out by saliva within few hours of application. To overcome the challenges, polymeric molds to be placed on an affected tooth (during carries and gum problems) were prepared and evaluated in vitro for sustained drug release for prolonged local action. Here, amoxicillin trihydrate and lidocaine hydrochloride were used as model drugs. Dental molds were prepared using corn zein, carbopol 934 P, gum karaya powder, and poloxamer 407 by mixing and solvent evaporation technique. Different physicochemical evaluation studies such as tooth adhesion test, surface pH, swelling index, and drug-distribution pattern were carried out. Percentage swelling varied from 56% to 93%. Average tooth adhesion strength and mean initial surface pH of the formulations were 50 g and 6.5, respectively. As assessed by scanning electron microscopy, drug distribution was uniform throughout the matrix. Cumulative percentage release of lidocaine hydrochloride and amoxicillin trihydrate in simulated saliva were 98% and 50%, respectively. In vitro drug-release studies revealed the sustained-release patterns of the drugs in simulated saliva at least for 24 h. The stability study shows that the drugs were stable in the formulations following the conditions as per ICH guideline. The formulation is a novel approach to deliver the drug(s) for a prolonged period for local action upon its application on an affected tooth.
Collapse
|
21
|
Sher P, Ingavle G, Ponrathnam S, Poddar P, Pawar AP. Modulation and optimization of drug release from uncoated low density porous carrier based delivery system. AAPS PharmSciTech 2009; 10:547-58. [PMID: 19424805 DOI: 10.1208/s12249-009-9239-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2008] [Accepted: 04/09/2009] [Indexed: 11/30/2022] Open
Abstract
The purpose of this research work was to explore an application of uncoated porous drug carrier prepared by single-step drug adsorption for a delivery system based on integration of floating and pulsatile principles intended for chronotherapy. This objective was achieved by utilizing 3(2) factorial design, solvent volume (X(1)) and drug amount (X(2)) as selected variables, for drug adsorption using solvents, methanol, and dichloromethane (DCM), of varying polarity. Nitrogen adsorption (N(2)), scanning electron microscopy of cross-sections, and atomic force microscopy were done to study adsorption patterns and their effect on release pattern. Drug release study was customized by performing for 6 h in acidic environment to mimic gastroretention followed by basic environment akin to transit phase. Correlation between porous data from mercury and N(2) adsorption was probably studied for the first time. Observed regression analysis values for pore volume, surface area, and drug release indicated the influence of selected variables. Total release range in acidic medium was 12.77-24.57% for methanol, 8.79-15.26% for DCM, and final release of 69.45-92.23% for methanol, and 60.16-99.99% for DCM influenced by varying internal geometries was observed. Present form of drug delivery system devoid of any additives/excipients influencing drug release shows distinct behavior from other approaches/technologies in chronotherapy by (a) observing desired low drug release (8%) in acidic medium, (b) overcoming the limitations of process variables caused by multiple formulation steps and different characteristic polymers, (c) reducing time consumption due to single step process, and (d) extending as controlled/extended release.
Collapse
|
22
|
Mohamad A, Dashevsky A. In Vitro and In Vivo Performance of a Multiparticulate Pulsatile Drug Delivery System. Drug Dev Ind Pharm 2008; 33:113-9. [PMID: 17454042 DOI: 10.1080/03639040601085433] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The objective of this study was to investigate the in vitro and in vivo drug release performance of a rupturable multiparticulate pulsatile system, coated with aqueous polymer dispersion Aquacoat ECD. Acetaminophen was used as a model drug, because in vivo performance can be monitored by measuring its concentration in saliva. Drug release was typical pulsatile, characterized by lag time, followed by fast drug release. Increasing the coating level of outer membrane lag time was clearly delayed. In vitro the lag time in 0.1 N HCl was longer, compared to phosphate buffer pH 7.4 because of ionisable ingredients present in the formulation (crosscarmelose sodium and sodium dodecyl sulphate). In vitro release was also longer in medium with higher ion concentration (0.9% NaCl solution compared to purified water); but independent of paddle rotation speed (50 vs.100 rpm). Macroscopically observation of the pellets during release experiment confirms that the rupturing of outer membrane was the main trigger for the onset of release. At the end of release outer membrane of all pellets was destructed and the content completely released. However, pellets with higher coating level and correspondingly longer lag time showed decreased bioavailability of acetaminophen. This phenomenon was described previously and explained by decreased liquid flow in the lower part of intestine. This disadvantage can be considered as a limitation for drugs (like acetaminophen) with high dose and moderate solubility; however, it should not diminish performance of the investigated system in principle.
Collapse
Affiliation(s)
- A Mohamad
- College of Pharmacy, Freie Universität Berlin, Kelchstr, Berlin, Germany
| | | |
Collapse
|
23
|
Li B, Zhu J, Zheng C, Gong W. A novel system for three-pulse drug release based on “tablets in capsule” device. Int J Pharm 2008; 352:159-64. [DOI: 10.1016/j.ijpharm.2007.10.043] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2007] [Revised: 09/03/2007] [Accepted: 10/21/2007] [Indexed: 11/29/2022]
|
24
|
Gazzaniga A, Maroni A, Sangalli ME, Zema L. Time-controlled oral delivery systems for colon targeting. Expert Opin Drug Deliv 2006; 3:583-97. [PMID: 16948555 DOI: 10.1517/17425247.3.5.583] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
In recent years, many research efforts have been spent in the achievement of selective delivery of drugs into the colon following oral administration. Indeed, colonic release is regarded as a beneficial approach to the pharmacological treatment or prevention of widespread large bowel pathologies, such as inflammatory bowel disease and adenocarcinoma. In addition, it is extensively explored as a potential means of enhancing the oral bioavailability of peptides, proteins and other biotechnological molecules, which are known to be less prone to enzymatic degradation in the large, rather than in the small, intestine. Based on these premises, several formulation strategies have been attempted in pursuit of colonic release, chiefly including microflora-, pH-, pressure- and time-dependent delivery technologies. In particular, this review is focused on the main design features and release performances of time-controlled devices, which rely on the relative constancy that is observed in the small intestinal transit time of dosage forms.
Collapse
Affiliation(s)
- Andrea Gazzaniga
- Istituto di Chimica Farmaceutica e Tossicologica P. Pratesi, Università di Milano, V.le Abruzzi 42, 20131 Milan, Italy.
| | | | | | | |
Collapse
|
25
|
Mohamad A, Dashevsky A. Development of pulsatile multiparticulate drug delivery system coated with aqueous dispersion Aquacoat® ECD. Int J Pharm 2006; 318:124-31. [PMID: 16759827 DOI: 10.1016/j.ijpharm.2006.03.022] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2006] [Revised: 03/08/2006] [Accepted: 03/22/2006] [Indexed: 11/19/2022]
Abstract
The objective of this study was to develop and evaluate a pulsatile multiparticulate drug delivery system (DDS), coated with aqueous dispersion Aquacoat ECD. A rupturable pulsatile drug delivery system consists of (i) a drug core; (ii) a swelling layer, comprising a superdisintegrant and a binder; and (iii) an insoluble, water-permeable polymeric coating. Upon water ingress, the swellable layer expands, resulting in the rupturing of outer membrane with subsequent rapid drug release. Regarding the cores, the lag time was shorter, when 10% (w/w) theophylline was layered on sugar cores compared with cores consisting of 100% theophylline. Regarding swelling layer, the release after lag time was fast and complete, when cross-linked carboxymethyl cellulose (AcDiSol) was used as a swelling agent. In contrast, a sustained release was achieved after the lag time, when low-substituted hydroxypropyl cellulose (L-HPC) and sodium starch glycolate (Explotab) were used as swelling agents. The optimal level of AcDiSol to achieve a fast and complete release after the lag time was 26% (w/w) (based on the weight of the coated pellets) for poorly soluble theophylline and 48% (w/w) for highly soluble propranolol HCl. The lag time can be controlled by the coating level of an outer membrane and increased with increasing coating level of the outer membrane. Outer membrane, formed using aqueous dispersion Aquacoat ECD was brittle and ruptured sufficiently to ensure fast drug release, compared to ethylcellulose membrane formed using organic solution. The addition of talc led to increase brittleness of membrane and was very advantageous because of (i) reduced sensitivity of lag time on variations in the coating level and (ii) fast and complete drug release. Drug release starts only after rupturing of outer membrane, which was illustrated by microscopical observation of pellet during release.
Collapse
Affiliation(s)
- Ahmad Mohamad
- College of Pharmacy, Department of Pharmaceutical Technology, Kelchstrasse 31, 12169 Berlin, Germany.
| | | |
Collapse
|
26
|
Efentakis M, Koligliati S, Vlachou M. Design and evaluation of a dry coated drug delivery system with an impermeable cup, swellable top layer and pulsatile release. Int J Pharm 2006; 311:147-56. [PMID: 16436321 DOI: 10.1016/j.ijpharm.2005.12.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2005] [Revised: 12/14/2005] [Accepted: 12/19/2005] [Indexed: 11/28/2022]
Abstract
In this investigation a novel oral pulsatile drug delivery system based on a core-in-cup dry coated tablet, where the core tablet surrounded on the bottom and circumference wall with inactive material, is proposed. The system consists of three different parts, a core tablet, containing the active ingredient, an impermeable outer shell and a top cover layer-barrier of a soluble polymer. The core contained either diclofenac sodium or ketoprofen as model drugs. The impermeable coating cup consisted of cellulose acetate propionate and the top cover layer of hydrophilic swellable materials, such as polyethylene oxide, sodium alginate or sodium carboxymethyl cellulose. The effect of the core, the polymer characteristics and quantity at the top cover layer, on the lag time and drug release was investigated. The results show that the system release of the drug after a certain lag time generally due to the erosion of the top cover layer. The quantity of the material, its characteristics (viscosity, swelling, gel layer thickness) and the drug solubility was found to modify lag time and drug release. The lag time increased when the quantity of top layer increased, whereas drug release decreased. The use of sodium carboxymethyl cellulose resulted in the greatest swelling, gel thickness and lag time, but the lowest drug release from the system. Polyethylene oxide showed an intermediate behaviour while, the sodium alginate exhibited the smallest swelling, gel thickness and the shortest lag time, but the fastest release. These findings suggest that drug delivery can be controlled by manipulation of these formulations.
Collapse
Affiliation(s)
- M Efentakis
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Athens, Panepistimiopolis, Zografou, 157 71 Athens, Greece.
| | | | | |
Collapse
|
27
|
Maroni A, Zema L, Cerea M, Sangalli ME. Oral pulsatile drug delivery systems. Expert Opin Drug Deliv 2005; 2:855-71. [PMID: 16296783 DOI: 10.1517/17425247.2.5.855] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In the field of modified release, there has been a growing interest in pulsatile delivery, which generally refers to the liberation of drugs following a programmable lag phase from the time of administration. In particular, the recent literature reports on a variety of pulsatile release systems intended for the oral route, which have been recognised as potentially beneficial to the chronotherapy of widespread diseases, such as bronchial asthma or angina pectoris, with mainly night or early morning symptoms. In addition, time-dependent colon delivery may also represent an appealing related application. The delayed liberation of orally administered drugs has been achieved through a range of formulation approaches, including single- or multiple-unit systems provided with release-controlling coatings, capsular devices and osmotic pumps. Based on these premises, the aim of this review is to outline the rational and prominent design strategies behind oral pulsatile delivery.
Collapse
Affiliation(s)
- Alessandra Maroni
- Istituto di Chimica Farmaceutica e Tossicologica, Università di Milano, Italy
| | | | | | | |
Collapse
|