1
|
Usmani O, Roche N, Wahab E, Israel S, Jenkins M, Trivedi R, Dorinsky P, Aurivillius M. A scintigraphy study of budesonide/glycopyrrolate/formoterol fumarate metered dose inhaler in patients with moderate-to-very severe chronic obstructive pulmonary disease. Respir Res 2021; 22:261. [PMID: 34620167 PMCID: PMC8496011 DOI: 10.1186/s12931-021-01813-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 07/28/2021] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Triple therapy with inhaled corticosteroids/long-acting muscarinic antagonists/long-acting β2-agonists (ICS/LAMA/LABA) is recommended for patients with chronic obstructive pulmonary disease (COPD) with continued symptoms or exacerbations, despite treatment with LAMA/LABA or ICS/LABA. The pulmonary, extrathoracic, and regional lung deposition patterns of a radiolabeled ICS/LAMA/LABA triple fixed-dose combination budesonide/glycopyrrolate/formoterol fumarate (BGF 320/18/9.6 μg), delivered via a single Aerosphere metered dose inhaler (MDI) were previously assessed in healthy volunteers and showed good deposition to the central and peripheral airways (whole lung deposition: 37.7%). Here, we report the findings assessing BGF in patients with moderate-to-very severe COPD. METHODS This phase I, single-dose, open-label gamma scintigraphy imaging study (NCT03906045) was conducted in patients with moderate-to-very severe COPD. Patients received two actuations of BGF MDI (160/9/4.8 μg per actuation) radiolabeled with technetium‑99‑pertechnetate, not exceeding 5 MBq per actuation. Immediately following each inhalation, patients performed a breath-hold of up to 10 s, then exhaled into an exhalation filter. Gamma scintigraphy imaging of the anterior and posterior views of the lungs and stomach, and a lateral head and neck view, were performed immediately after exhalation. The primary objective of the study was to assess the pulmonary deposition of BGF. Secondary objectives assessed the deposited dose of radiolabeled BGF in the oropharyngeal and stomach regions, on the actuator, and on the exhalation filter in addition to regional airway deposition patterns in the lungs. RESULTS The mean BGF emitted dose deposited in the lungs was 32.1% (standard deviation [SD] 15.6) in patients with moderate-to-very severe COPD, 35.2% (SD 12.8) in patients with moderate COPD, and 28.7% (SD 18.4) in patients with severe/very severe COPD. Overall, the mean normalized outer/inner ratio was 0.55 (SD 0.19), while the standardized central/peripheral ratio was 2.21 (SD 1.64). CONCLUSIONS Radiolabeled BGF 320/18/9.6 μg was efficiently delivered and deposited throughout the entire lung, including large and small airways, in patients with moderate-to-very severe COPD, with similar deposition in patients with moderate COPD and patients with severe/very severe COPD. TRIAL REGISTRATION ClinicalTrials.gov, NCT03906045. Registered 8 April 2019, https://clinicaltrials.gov/ct2/show/NCT03906045.
Collapse
Affiliation(s)
- Omar Usmani
- Asthma Lab, National Heart and Lung Institute (NHLI), Imperial College London & Royal Brompton Hospital, South Block, Royal Brompton Campus, Sydney St, Chelsea, London, SW3 6NP, UK.
| | - Nicolas Roche
- Respiratory Medicine, Hôpital Cochin (AP-HP), University of Paris, Cochin Institute, Paris, France
| | | | | | | | | | | | | |
Collapse
|
2
|
Kwok PCL, Wallin M, Dolovich MB, Chan HK. Studies of Radioaerosol Deposition in the Respiratory Tract. Semin Nucl Med 2019; 49:62-70. [PMID: 30545519 DOI: 10.1053/j.semnuclmed.2018.10.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Deposition of aerosols in the respiratory tract can be quantitatively and qualitatively studied by scintigraphy. The most commonly used radionuclide for this purpose is technetium-99m. The effects of various factors on particle deposition have been investigated by using radiolabeled aerosols in the past decade. Most of these studies were in vivo but some were in vitro or ex vivo. The factors examined include particle size, formulation, inhaler design, inhalation flowrate, body posture, and gravity. They have been shown to influence pulmonary deposition, nasal high flow nebulization, and intranasal delivery. A thorough understanding of the various factors is required for the advancement of respiratory-drug delivery. Scintigraphy is a powerful technique that can assist in this regard.
Collapse
Affiliation(s)
- Philip Chi Lip Kwok
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| | - Martin Wallin
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| | - Myrna B Dolovich
- Department of Medicine, McMaster University, Hamilton, ON, Canada.
| | - Hak-Kim Chan
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| |
Collapse
|
3
|
Orally inhaled migraine therapy: Where are we now? Adv Drug Deliv Rev 2018; 133:131-134. [PMID: 30189270 DOI: 10.1016/j.addr.2018.08.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 08/28/2018] [Accepted: 08/31/2018] [Indexed: 11/24/2022]
Abstract
Migraine is a debilitating disease that affects 9% of men and 19% of women worldwide with high socio-economic and personal impact. Surveys indicate that migraineurs are among the most dissatisfied with available therapeutic options, predominantly given via oral or injectable routes, citing side effects as the primary complaint. Orally inhaled therapies have the potential to offer faster onset of action with fewer side effects compared to existing therapies, yet development has stalled. Despite emerging therapies such as calcitonin gene-related peptide antagonists, there are still good opportunities for repositioning migraine drugs via the inhaled route.
Collapse
|
4
|
Kappeler D, Sommerer K, Kietzig C, Huber B, Woodward J, Lomax M, Dalvi P. Pulmonary deposition of fluticasone propionate/formoterol in healthy volunteers, asthmatics and COPD patients with a novel breath-triggered inhaler. Respir Med 2018; 138:107-114. [PMID: 29724381 DOI: 10.1016/j.rmed.2018.03.029] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 02/08/2018] [Accepted: 03/28/2018] [Indexed: 11/16/2022]
Abstract
INTRODUCTION A combination of fluticasone propionate/formoterol fumarate (FP/FORM) has been incorporated within a novel, breath-triggered device, named K-haler®. This low resistance device requires a gentle inspiratory effort to actuate it, triggering at an inspiratory flow rate of approximately 30 L/min; thus avoiding the need for coordination of inhalation with manual canister depression. The aim of the study was to evaluate total and regional pulmonary deposition of FP/FORM when administered via the K-haler device. MATERIALS AND METHODS Twelve healthy subjects, 12 asthmatics, and 12 COPD patients each received a single dose of 2 puffs 99mtechnetium-labelled FP/FORM 125/5 μg. A gamma camera was used to obtain anterior and posterior two-dimensional images of drug deposition. Prior transmission scans (using a99mtechnetium flood source) allowed the definition of regions of interest and calculation of attenuation correction factors. Image analysis was performed per standardised methods. RESULTS Of 36 subjects, 35 provided evaluable post-dose scintigraphic data. Mean subject ages were 35.7 (healthy), 44.5 (asthma) and 61.7 years (COPD); mean FEV1% predicted values were 109.8%, 77.4% and 43.2%, respectively. Mean pulmonary deposition was 26.6% (healthy), 44.7% (asthma), 39.0% (COPD) of the delivered dose. The respective mean penetration indices (peripheral:central ratio normalised to a transmission lung scan) were 0.44, 0.31 and 0.30. CONCLUSION FP/FORM administration via the K-haler device resulted in high lung deposition in patients with obstructive lung disease but somewhat lesser deposition in healthy subjects. Regional deposition data demonstrated drug deposition in both the central and peripheral regions in all subject populations. EUDRACT NUMBER 2015-000744-42.
Collapse
Affiliation(s)
| | - Knut Sommerer
- Inamed GmbH, Robert-Koch-Allee 29, Gauting, Germany.
| | | | - Bärbel Huber
- Inamed GmbH, Robert-Koch-Allee 29, Gauting, Germany.
| | - Jo Woodward
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| | - Mark Lomax
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| | - Prashant Dalvi
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| |
Collapse
|
5
|
Abstract
In 1956, Riker Laboratories, Inc., (now 3 M Drug Delivery Systems) introduced the first pressurized metered dose inhaler (MDI). In many respects, the introduction of the MDI marked the beginning of the modern pharmaceutical aerosol industry. The MDI was the first truly portable and convenient inhaler that effectively delivered drug to the lung and quickly gained widespread acceptance. Since 1956, the pharmaceutical aerosol industry has experienced dramatic growth. The signing of the Montreal Protocol in 1987 led to a surge in innovation that resulted in the diversification of inhaler technologies with significantly enhanced delivery efficiency, including modern MDIs, dry powder inhalers, and nebulizer systems. The innovative inhalers and drugs discovered by the pharmaceutical aerosol industry, particularly since 1956, have improved the quality of life of literally hundreds of millions of people. Yet, the delivery of therapeutic aerosols has a surprisingly rich history dating back more than 3500 years to ancient Egypt. The delivery of atropine and related compounds has been a crucial inhalation therapy throughout this period and the delivery of associated structural analogs remains an important therapy today. Over the centuries, discoveries from many cultures have advanced the delivery of therapeutic aerosols. For thousands of years, therapeutic aerosols were prepared by the patient or a physician with direct oversight of the patient using custom-made delivery systems. However, starting with the Industrial Revolution, advancements in manufacturing resulted in the bulk production of therapeutic aerosol delivery systems produced by people completely disconnected from contact with the patient. This trend continued and accelerated in the 20th century with the mass commercialization of modern pharmaceutical inhaler products. In this article, we will provide a summary of therapeutic aerosol delivery from ancient times to the present along with a look to the future. We hope that you will find this chronological summary intriguing and informative.
Collapse
|
6
|
Stein SW, Sheth P, Hodson PD, Myrdal PB. Advances in metered dose inhaler technology: hardware development. AAPS PharmSciTech 2014; 15:326-38. [PMID: 24357110 PMCID: PMC3969498 DOI: 10.1208/s12249-013-0062-y] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2013] [Accepted: 11/15/2013] [Indexed: 11/30/2022] Open
Abstract
Pressurized metered dose inhalers (MDIs) were first introduced in the 1950s and they are currently widely prescribed as portable systems to treat pulmonary conditions. MDIs consist of a formulation containing dissolved or suspended drug and hardware needed to contain the formulation and enable efficient and consistent dose delivery to the patient. The device hardware includes a canister that is appropriately sized to contain sufficient formulation for the required number of doses, a metering valve capable of delivering a consistent amount of drug with each dose delivered, an actuator mouthpiece that atomizes the formulation and serves as a conduit to deliver the aerosol to the patient, and often an indicating mechanism that provides information to the patient on the number of doses remaining. This review focuses on the current state-of-the-art of MDI hardware and includes discussion of enhancements made to the device's core subsystems. In addition, technologies that aid the correct use of MDIs will be discussed. These include spacers, valved holding chambers, and breath-actuated devices. Many of the improvements discussed in this article increase the ability of MDI systems to meet regulatory specifications. Innovations that enhance the functionality of MDIs continue to be balanced by the fact that a key advantage of MDI systems is their low cost per dose. The expansion of the health care market in developing countries and the increased focus on health care costs in many developed countries will ensure that MDIs remain a cost-effective crucial delivery system for treating pulmonary conditions for many years to come.
Collapse
Affiliation(s)
- Stephen W. Stein
- />3M Drug Delivery Systems, 3M Center—Building 260-3A-05, St. Paul, Minnesota 55144 USA
| | - Poonam Sheth
- />College of Pharmacy, University of Arizona, 1703 E. Mabel St., P.O. Box 210207, Tucson, Arizona 85721 USA
| | - P. David Hodson
- />3M Healthcare Limited, Dishley House, Bishop Meadow Road, Loughborough, Leicestershire LE11 5RE UK
| | - Paul B. Myrdal
- />College of Pharmacy, University of Arizona, 1703 E. Mabel St., P.O. Box 210207, Tucson, Arizona 85721 USA
| |
Collapse
|
7
|
Stein SW, Sheth P, Hodson PD, Myrdal PB. Advances in metered dose inhaler technology: hardware development. AAPS PharmSciTech 2013. [PMID: 24357110 DOI: 10.1208/s12249-013-0062-y.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Pressurized metered dose inhalers (MDIs) were first introduced in the 1950s and they are currently widely prescribed as portable systems to treat pulmonary conditions. MDIs consist of a formulation containing dissolved or suspended drug and hardware needed to contain the formulation and enable efficient and consistent dose delivery to the patient. The device hardware includes a canister that is appropriately sized to contain sufficient formulation for the required number of doses, a metering valve capable of delivering a consistent amount of drug with each dose delivered, an actuator mouthpiece that atomizes the formulation and serves as a conduit to deliver the aerosol to the patient, and often an indicating mechanism that provides information to the patient on the number of doses remaining. This review focuses on the current state-of-the-art of MDI hardware and includes discussion of enhancements made to the device's core subsystems. In addition, technologies that aid the correct use of MDIs will be discussed. These include spacers, valved holding chambers, and breath-actuated devices. Many of the improvements discussed in this article increase the ability of MDI systems to meet regulatory specifications. Innovations that enhance the functionality of MDIs continue to be balanced by the fact that a key advantage of MDI systems is their low cost per dose. The expansion of the health care market in developing countries and the increased focus on health care costs in many developed countries will ensure that MDIs remain a cost-effective crucial delivery system for treating pulmonary conditions for many years to come.
Collapse
Affiliation(s)
- Stephen W Stein
- 3M Drug Delivery Systems, 3M Center-Building 260-3A-05, St. Paul, Minnesota, 55144, USA,
| | | | | | | |
Collapse
|
8
|
|
9
|
|
10
|
Longest PW, Hindle M. Quantitative analysis and design of a spray aerosol inhaler. Part 1: effects of dilution air inlets and flow paths. J Aerosol Med Pulm Drug Deliv 2009; 22:271-83. [PMID: 19466904 DOI: 10.1089/jamp.2008.0739] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The objective of this study was to evaluate the effects of modifying inhaler design variables on aerosol drug deposition within the mouthpiece for a representative spray system using a quantitative analysis and design approach. METHODS Capillary aerosol generation (CAG) was selected as a model spray aerosol system in conjunction with four prototype inhaler body and mouthpiece combinations. In vitro experiments were used to determine drug deposition in the mouthpiece and induction port. Validated computational fluid dynamics (CFD) simulations were implemented to establish relationships between design variables, transport characteristics, and aerosol drug deposition. RESULTS Results of this study indicated that both the size of the upstream dilution air inlets and the flow pathway configuration near the spray nozzle significantly influenced aerosol transport and deposition. CFD results showed that the primary transport characteristics associated with drug deposition were turbulence intensity and the effective diameter of the mouthpiece. Strong quantitative correlations were developed between the identified transport characteristics and mouthpiece drug deposition. CONCLUSIONS Based on quantitative analysis and design, turbulence intensity and effective mouthpiece diameter were identified as key transport characteristics within the design space that directly influenced aerosol deposition and may be used to predict and optimize drug delivery to the patient.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, Virginia., Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia.
| | | |
Collapse
|
11
|
Shrewsbury SB, Kori SH, Miller SD, Pedinoff A, Weinstein S. Randomized, double-blind, placebo-controlled study of the safety, tolerability and pharmacokinetics of MAP0004 (orally-inhaled DHE) in adult asthmatics. Curr Med Res Opin 2008; 24:1977-85. [PMID: 18534051 DOI: 10.1185/03007990802160677] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND MAP0004 (a proprietary formulation of dihydroergotamine mesylate [DHE]) for inhaled delivery is being developed for acute migraine treatment. Because asthma and migraine often occur as co-morbid conditions, it is considered important to study the safety of MAP0004 in a population of asthmatic adults and to confirm that the pharmacokinetics of DHE, when inhaled by asthmatic subjects, were comparable to a population of healthy volunteers. The safety, tolerability, and pharmacokinetics of orally-inhaled MAP0004 administered by the Tempo inhaler were studied in adult asthmatics. SCOPE This was a randomized, double-blind, placebo-controlled study of two doses of inhaled MAP0004. Eligible subjects were randomized in a 2 : 1 ratio to MAP0004 or placebo and observed for 4 h after each dose. Pharmacokinetic parameters were determined pre-dose and up to 36 h post-dose. FINDINGS Among 19 subjects, geometric mean AUC(0-36) was 6754 pg.h/mL and geometric mean AUC(0-inf) was 7483 pg.h/mL. Geometric mean t(max) was 9.6 min, geometric mean C(max) was 3174 pg/mL, and geometric mean t((1/2)) was 9.5 h. Overall, 13 of 19 (68%) subjects reported at least one adverse event, most commonly nausea, vomiting, dysgeusia, and headache. CONCLUSION MAP0004 results in rapid and efficient systemic absorption in asthmatic subjects. Systemic DHE concentrations were similar to those previously reported in healthy subjects, and no clinically relevant safety issues were observed. While this small study was suitable for pharmacokinetic analysis and conclusions, MAP0004 use in migraineurs with concomitant stable asthma should be supported by larger studies of longer duration to confirm that it does not present additional safety risks compared to non-asthmatic migraineurs.
Collapse
|