1
|
Azeem A, Singh G, Li L, Chan HK, Yang R, Cheng S, Kourmatzis A. Quantifying Agglomerate-to-Wall Impaction in Dry Powder Inhalers. Pharm Res 2023; 40:307-319. [PMID: 36471024 DOI: 10.1007/s11095-022-03446-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Accepted: 11/20/2022] [Indexed: 12/12/2022]
Abstract
PURPOSE The probability of agglomerate-to-wall collision was quantified using a unique image processing technique applied to high-speed microscopic images. The study aimed to investigate the effects of flow rate and particle size on the percentage of colliding agglomerates detected within an in-house powder dispersion device. METHOD The device consists of a swirl chamber and two tangential inlets in various configurations, designed to emulate the geometric features of commercial devices such as the Aerolizer® and Osmohaler®. The test cases were conducted with constant flow rates of 30 SLPM and 60 SLPM. Four powder samples were tested, including carrier Respitose® SV010 (median volume diameter 104 µm, span 1.7) and mannitol of three constituent primary particle sizes (3 µm, 5 µm and 7 µm; span 1.6 - 1.9). RESULTS At the lower flow rate of 30 SLPM, collision frequencies were significantly different between powders of different constituent particle sizes, but the effects of powder properties diminished on increasing the flow rate to 60 SLPM. At the higher flow rate, all powders experienced a significant increase in the proportion of colliding particles. CONCLUSION Analysis of collision events showed that the probability of collision for each agglomerate increased with agglomerate diameter and velocity. Experimental data of agglomerate-to-wall collision were utilised to develop a logistic regression model that can accurately predict collisions with various powders and flow rates.
Collapse
Affiliation(s)
- Athiya Azeem
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Gajendra Singh
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2006, Australia
- School of Engineering, IIT Mandi, Mandi, HP, 175075, India
| | - Lunjian Li
- School of Materials Science and Engineering, UNSW Sydney, Sydney, NSW, 2052, Australia
| | - Hak-Kim Chan
- School of Pharmacy, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Runyu Yang
- School of Materials Science and Engineering, UNSW Sydney, Sydney, NSW, 2052, Australia
| | - Shaokoon Cheng
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia
| | - Agisilaos Kourmatzis
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2006, Australia.
| |
Collapse
|
2
|
Feng J, Wang C, Zhang Y, Chan KC, Liu CH, Chao CY, Fu SC. Particle resuspension from a flow-induced fluttering flexible substrate. POWDER TECHNOL 2022. [DOI: 10.1016/j.powtec.2022.118163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
3
|
A CFD-DEM investigation of powder transport and aerosolization in ELLIPTA® dry powder inhaler. POWDER TECHNOL 2022; 409. [DOI: 10.1016/j.powtec.2022.117817] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
4
|
Sulaiman M, Liu X, Sundaresan S. Effects of dose loading conditions and device geometry on the transport and aerosolization in dry powder inhalers: A simulation study. Int J Pharm 2021; 610:121219. [PMID: 34699949 DOI: 10.1016/j.ijpharm.2021.121219] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 10/20/2022]
Abstract
The transport and aerosolization of particles are studied in several different dry powder inhaler geometries via Computational Fluid Dynamics-Discrete Element Method (CFD-DEM) simulations. These simulations combine Large Eddy Simulation of gas with Discrete Element Model simulation of all the carrier particles and a representative subset of the active pharmaceutical ingredient (API) particles. The purpose of the study is to probe the dominant mechanism leading to the release of the API particles and to demonstrate the value of the CFD-DEM simulations where one tracks the motion of all the carrier and API particles. Simulations are performed at different inhalation rates and initial dose loading conditions for the screen-haler geometry, a simple cylindrical tube inhaler, and five different geometry modifications that took the form of bumpy walls and baffles. These geometry modifications alter the residence time of the powder sample in the inhaler, pressure drop across the inhaler, the severity of gas-carrier interactions, and the number of collisions experienced by the carrier particles, all of which are quantified. The quality of aerosolization is found to correlate with the average air-carrier slip velocity, while collisions played only a secondary role. Some geometry modifications improved aerosolization quality with very little increase in the pressure drop across the device.
Collapse
Affiliation(s)
- Mostafa Sulaiman
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ, USA.
| | - Xiaoyu Liu
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ, USA
| | - Sankaran Sundaresan
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ, USA
| |
Collapse
|
5
|
Sou T, Bergström CAS. Contemporary Formulation Development for Inhaled Pharmaceuticals. J Pharm Sci 2020; 110:66-86. [PMID: 32916138 DOI: 10.1016/j.xphs.2020.09.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 09/02/2020] [Accepted: 09/03/2020] [Indexed: 12/22/2022]
Abstract
Pulmonary delivery has gained increased interests over the past few decades. For respiratory conditions, targeted drug delivery directly to the site of action can achieve a high local concentration for efficacy with reduced systemic exposure and adverse effects. For systemic conditions, the unique physiology of the lung evolutionarily designed for rapid gaseous exchange presents an entry route for systemic drug delivery. Although the development of inhaled formulations has come a long way over the last few decades, many aspects of it remain to be elucidated. In particular, a reliable and well-understood method for in vitro-in vivo correlations remains to be established. With the rapid and ongoing advancement of technology, there is much potential to better utilise computational methods including different types of modelling and simulation approaches to support inhaled formulation development. This review intends to provide an introduction on some fundamental concepts in pulmonary drug delivery and inhaled formulation development followed by discussions on some challenges and opportunities in the translation of inhaled pharmaceuticals from preclinical studies to clinical development. The review concludes with some recent advancements in modelling and simulation approaches that could play an increasingly important role in modern formulation development of inhaled pharmaceuticals.
Collapse
Affiliation(s)
- Tomás Sou
- Drug Delivery, Department of Pharmacy, Uppsala University, Uppsala, Sweden; Pharmacometrics, Department of Pharmacy, Uppsala University, Uppsala, Sweden.
| | - Christel A S Bergström
- Drug Delivery, Department of Pharmacy, Uppsala University, Uppsala, Sweden; The Swedish Drug Delivery Center, Department of Pharmacy, Uppsala University, Uppsala, Sweden
| |
Collapse
|
6
|
Dosing challenges in respiratory therapies. Int J Pharm 2018; 548:659-671. [PMID: 30033395 DOI: 10.1016/j.ijpharm.2018.07.007] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Revised: 06/20/2018] [Accepted: 07/01/2018] [Indexed: 01/16/2023]
Abstract
The pulmonary route of administration has been commonly used for local lung conditions such as asthma and chronic obstructive pulmonary disease (COPD). Recently, with the advent of new technologies available for both formulation and device design, molecules usually delivered at high doses, such as antibiotics and insulin to treat cystic fibrosis (CF) and diabetes, respectively, can now be delivered by inhalation as a dry powder. These molecules are generally delivered in milligrams instead of traditional microgram quantities. High dose delivery is most commonly achieved via dry powder inhalers (DPIs), breath activated devices designed with a formulated powder containing micronized drug with aerodynamic diameters between 1 and 5 µm. The powder formulation may also contain other excipients and/or carrier particles to improve the flowability and aerosol dispersion of the powder. A drawback with high doses is that the formulation contains a great number of fine particles, leading to a greater degree of cohesive forces, producing strongly bound agglomerates. With greater cohesive forces holding fine particles together, higher dispersion forces are needed for efficient de-agglomeration and aerosolisation. This requirement of greater dispersion forces has led to different dry powder formulations and vastly different inhaler designs. The purpose of this review is to evaluate the different formulation types, various DPI devices currently available, and how these affect the aerosolisation process and delivery of high dosed inhalable dry powder formulations to the lungs.
Collapse
|
7
|
Kim KS, Kim JH, Jin SG, Kim DW, Kim JO, Yong CS, Youn YS, Oh KT, Woo JS, Choi HG. Formulation of novel dry powder inhalation for fluticasone propionate and salmeterol xinafoate with capsule-based device. Pharm Dev Technol 2017; 23:158-166. [DOI: 10.1080/10837450.2017.1342656] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Kyeong Soo Kim
- College of Pharmacy & Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Republic of Korea
- Pharmaceutical Research Centre, Hanmi Pharm. Co., Hwaseong, Republic of Korea
| | - Jeong Hyun Kim
- College of Pharmacy & Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Republic of Korea
- Pharmaceutical Research Centre, Hanmi Pharm. Co., Hwaseong, Republic of Korea
| | - Sung Giu Jin
- College of Pharmacy & Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Republic of Korea
| | - Dong Wuk Kim
- College of Pharmacy & Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Republic of Korea
| | - Jong Oh Kim
- College of Pharmacy, Yeungnam University, Gyongsan, Republic of Korea
| | - Chul Soon Yong
- College of Pharmacy, Yeungnam University, Gyongsan, Republic of Korea
| | - Yu Seok Youn
- School of Pharmacy, Sungkyunkwan University, Suwon, Republic of Korea
| | - Kyung Taek Oh
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Jong Soo Woo
- Pharmaceutical Research Centre, Hanmi Pharm. Co., Hwaseong, Republic of Korea
| | - Han-Gon Choi
- College of Pharmacy & Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Republic of Korea
| |
Collapse
|
8
|
Parumasivam T, Leung SSY, Tang P, Mauro C, Britton W, Chan HK. The Delivery of High-Dose Dry Powder Antibiotics by a Low-Cost Generic Inhaler. AAPS JOURNAL 2016; 19:191-202. [PMID: 27679516 DOI: 10.1208/s12248-016-9988-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 09/09/2016] [Indexed: 01/31/2023]
Abstract
The routine of loading multiple capsules for delivery of high-dose antibiotics is time consuming, which may reduce patient adherence to inhaled treatment. To overcome this limitation, an investigation was carried out using four modified versions of the Aerolizer® that accommodate a size 0 capsule for delivery of high payload formulations. In some prototypes, four piercing pins of 0.6 mm each were replaced with a single centrally located 1.2-mm pin and one-third reduced air inlet of the original design. The performance of these inhalers was evaluated using spray-dried antibiotic powders with distinct morphologies: spherical particles with a highly corrugated surface (colistin and tobramycin) and needle-like particles (rifapentine). The inhalers were tested at capsule loadings of 50 mg (colistin), 30 mg (rifapentine) and 100 mg (tobramycin) using a multistage liquid impinger (MSLI) operating at 60 L/min. The device with a single pin and reduced air inlet showed a superior performance than the other prototypes in dispersing colistin and rifapentine powders, with a fine particle fraction (FPF wt% <5 μm in the aerosol) between 62 and 68%. Subsequently, an Aerolizer® with the same configuration (single pin and one-third air inlet) that accommodates a size 00 capsule was designed to increase the payload of colistin and rifapentine. The performance of the device at various inspiratory flow rates and air volumes achievable by most cystic fibrosis (CF) patients was examined at the maximum capsule loading of 100 mg. The device showed optimal performance at 45 L/min with an air volume of 1.5-2.0 L for colistin and 60 L/min with an air volume of 2.0 L for rifapentine. In conclusion, the modified size 00 Aerolizer® inhaler as a low-cost generic device demonstrated promising results for delivery of various high-dose formulations for treatment of lung infections.
Collapse
Affiliation(s)
- Thaigarajan Parumasivam
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Sharon S Y Leung
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Patricia Tang
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Citterio Mauro
- R & D and Industrialization, Plastiape S.p.A., 23875, Osnago, Italy
| | - Warwick Britton
- Tuberculosis Research Program, Centenary Institute, The University of Sydney, Sydney, NSW, 2006, Australia.,Infectious Diseases and Immunology, Sydney Medical School, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, NSW, 2006, Australia.
| |
Collapse
|
9
|
Hassoun M, Ho S, Muddle J, Buttini F, Parry M, Hammond M, Forbes B. Formulating powder-device combinations for salmeterol xinafoate dry powder inhalers. Int J Pharm 2015; 490:360-7. [PMID: 25987210 DOI: 10.1016/j.ijpharm.2015.05.028] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 05/08/2015] [Accepted: 05/11/2015] [Indexed: 10/23/2022]
Abstract
Using salmeterol xinafoate (SX) as an active pharmaceutical ingredient, the effects of carrier lactose particle type, total lactose fines content and device resistance on dry powder inhaler performance were investigated in vitro. To mimic drug levels in commercial preparations, interactive mixtures containing 0.58% w/w SX were prepared by low shear tumble mixing. Three types of milled inhalation grade lactose were used (Lactohale(®) LH 200, Respitose(®) ML006 and ML001) and the concentration of fine lactose (Lactohale(®) 300) added was varied. The in vitro deposition of each mixture was studied using a next generation impactor and inhaler devices exhibiting different resistances, Rotahaler(®)<Aerolizer(®)<Handihaler(®). Aerosol performance was evaluated based on the emitted dose (ED), mass median aerodynamic diameter (MMAD) ± geometric standard deviation (GSD) and fine particle fraction (FPF). Increases of up to eight-fold in FPF were observed with increasing intrinsic fine lactose content. The addition of extra fine lactose increased the FPF further, although the effect diminished as more fines were added. The Aerolizer produced the best aerosol performance with any given powder blend, although suitable formulations were identified for each device as defined by the a priori success criteria: >80% ED and MMAD ± GSD between 1-5 μm. The results confirmed the factors under investigation to be important determinants of product performance, but demonstrated using realistic conditions how individual factor impact may be enhanced or mitigated by inter-dependency.
Collapse
Affiliation(s)
- Mireille Hassoun
- Department of Pharmacy, King's College London, 150 Stamford Street, London SE1 9NH, UK
| | - Shirlene Ho
- Department of Pharmacy, King's College London, 150 Stamford Street, London SE1 9NH, UK
| | - Joanna Muddle
- Department of Pharmacy, King's College London, 150 Stamford Street, London SE1 9NH, UK
| | - Francesca Buttini
- Department of Pharmacy, King's College London, 150 Stamford Street, London SE1 9NH, UK; Department of Pharmacy, University of Parma, Parco Area delle Scienze 27/a, Parma 43124, Italy
| | - Mark Parry
- Intertek-Melbourn Scientific Limited, Saxon Way, Melbourn SG8 6DN, UK
| | - Mark Hammond
- Intertek-Melbourn Scientific Limited, Saxon Way, Melbourn SG8 6DN, UK
| | - Ben Forbes
- Department of Pharmacy, King's College London, 150 Stamford Street, London SE1 9NH, UK.
| |
Collapse
|
10
|
Chan JGY, Wong J, Zhou QT, Leung SSY, Chan HK. Advances in device and formulation technologies for pulmonary drug delivery. AAPS PharmSciTech 2014; 15:882-97. [PMID: 24728868 DOI: 10.1208/s12249-014-0114-y] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Accepted: 03/13/2014] [Indexed: 12/31/2022] Open
Abstract
Inhaled pharmaceuticals are formulated and delivered differently according to the therapeutic indication. However, specific device-formulation coupling is often fickle, and new medications or indications also demand new strategies. The discontinuation of chlorofluorocarbon propellants has seen replacement of older metered dose inhalers with dry powder inhaler formulations. High-dose dry powder inhalers are increasingly seen as an alternative dosage form for nebulised medications. In other cases, new medications have completely bypassed conventional inhalers and been formulated for use with unique inhalers such as the Staccato® device. Among these different devices, integration of software and electronic assistance has become a shared trend. This review covers recent device and formulation advances that are forming the current landscape of inhaled therapeutics.
Collapse
|
11
|
Zhou Q(T, Tang P, Leung SSY, Chan JGY, Chan HK. Emerging inhalation aerosol devices and strategies: where are we headed? Adv Drug Deliv Rev 2014; 75:3-17. [PMID: 24732364 DOI: 10.1016/j.addr.2014.03.006] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2014] [Revised: 03/23/2014] [Accepted: 03/24/2014] [Indexed: 02/07/2023]
Abstract
Novel inhaled therapeutics including antibiotics, vaccines and anti-hypertensives, have led to innovations in designing suitable delivery systems. These emerging design technologies are in urgent demand to ensure high aerosolisation performance, consistent efficacy and satisfactory patient adherence. Recent vibrating-mesh and software technologies have resulted in nebulisers that have remarkably accurate dosing and portability. Alternatively, dry powder inhalers (DPIs) have become highly favourable for delivering high-dose and single-dose drugs with the aid of advanced particle engineering. In contrast, innovations are needed to overcome the technical constrains in drug-propellant incompatibility and delivering high-dose drugs with pressurised metered dose inhalers (pMDIs). This review discusses recent and emerging trends in pulmonary drug delivery systems.
Collapse
|
12
|
Ngoc NTQ, Chang L, Jia X, Lau R. Experimental investigation of design parameters on dry powder inhaler performance. Int J Pharm 2013; 457:92-100. [DOI: 10.1016/j.ijpharm.2013.08.072] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 08/20/2013] [Accepted: 08/26/2013] [Indexed: 11/27/2022]
|
13
|
Behara SRB, Farkas DR, Hindle M, Longest PW. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications. Pharm Res 2013; 31:360-72. [PMID: 23949304 DOI: 10.1007/s11095-013-1165-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 07/28/2013] [Indexed: 01/31/2023]
Abstract
PURPOSE The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. METHODS DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. RESULTS The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. CONCLUSIONS High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD < 1.5 μm, FPF<5 μm/ED > 90%, and ED > 80%.
Collapse
Affiliation(s)
- Srinivas R B Behara
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, Virginia, 23284-3015, USA
| | | | | | | |
Collapse
|
14
|
Kumar S, Sharma S, Vasudeva N. Chemical compositions of Cinnamomum tamala oil from two different regions of India. ASIAN PACIFIC JOURNAL OF TROPICAL DISEASE 2012. [DOI: 10.1016/s2222-1808(12)60260-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|