1
|
Zhu Q, Gou D, Chan HK, Kourmatzis A, Yang R. Effects of the mouthpiece and chamber of Turbuhaler® on the aerosolization of API-only powder formulations. Int J Pharm 2023; 637:122871. [PMID: 36948474 DOI: 10.1016/j.ijpharm.2023.122871] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/13/2023] [Accepted: 03/15/2023] [Indexed: 03/24/2023]
Abstract
Powder dispersion in dry powder inhalers (DPIs) is affected by powder formulations as well as the design of a device. This paper conducted a numerical investigation based on the coupled computational fluid dynamics (CFD) and discrete element method (DEM) to evaluate the changes of the design of a commercial DPI device Turbuhaler® on the aerosolization of an API-only formulation. Six different designs were proposed by modifying the mouthpiece and chamber of the original geometry which was reconstructed from a CT-scan of the Turbuhaler, and their performances in terms of powder deposition in the device and fine powder fraction (FPF) were evaluated. The resistance of the device was observed to vary with different designs. For the change of the mouthpiece, the device with a cylindrical mouthpiece had the least resistance and the lowest FPF emitted among all the devices, confirming the important role of the spiral mouthpiece on powder dispersion. Reducing the mouthpiece size caused more powder deposition in the inhaler due to higher airflow velocity, but FPF emitted increased compared to the original design as more powder dispersion occurred inside the mouthpiece. The half-length mouthpiece design reduced device resistance to increase airflow velocity and average collision energy, resulting in an increase in FPF loaded but a decrease in the number of collisions. For the change of the chamber, the domed chamber design increased the powder dispersion time and thus enhanced the frequency and energy of particle collisions, which eventually led to an increase in FPF loaded. At fixed flow rates, the powder dispersion efficiency was a function of the device resistance with higher device resistance causing an increase in the FPF loaded. However, it is important for the patient's attainable pressure drop to be considered in this context. Correlations between the aerosolization efficiency and the ratio of the average collision energy and cohesion energy were established based on model-predicted quantities.
Collapse
Affiliation(s)
- Qixuan Zhu
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia
| | - Dazhao Gou
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Sydney Pharmacy School, The University of Sydney, NSW 2006, Australia
| | - Agisilaos Kourmatzis
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006, Australia
| | - Runyu Yang
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia.
| |
Collapse
|
2
|
Numerical Modeling of Particle Dynamics Inside a Dry Powder Inhaler. Pharmaceutics 2022; 14:pharmaceutics14122591. [PMID: 36559084 PMCID: PMC9783107 DOI: 10.3390/pharmaceutics14122591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/11/2022] [Accepted: 11/18/2022] [Indexed: 11/26/2022] Open
Abstract
The development of novel dry powders for dry powder inhalers (DPIs) requires the in vitro assessment of DPI aerodynamic performance. As a potential complementary method, in silico numerical simulations can provide additional information about the mechanisms that guide the particles and their behavior inside DPIs. The aim of this study was to apply computational fluid dynamics (CFDs) coupled with a discrete phase model (DPM) to describe the forces and particle trajectories inside the RS01® as a model DPI device. The methodology included standard fluid flow equations but also additional equations for the particle sticking mechanism, as well as particle behavior after contacting the DPI wall surface, including the particle detachment process. The results show that the coefficient of restitution between the particle and the impact surface does not have a high impact on the results, meaning that all tested combinations gave similar output efficiencies and particle behaviors. No sliding or rolling mechanisms were observed for the particle detachment process, meaning that simple bouncing off or deposition particle behavior is present inside DPIs. The developed methodology can serve as a basis for the additional understanding of the particles' behavior inside DPIs, which is not possible using only in vitro experiments; this implies the possibility of increasing the efficiency of DPIs.
Collapse
|
3
|
Zhu Q, Gou D, Li L, Chan HK, Yang R. Numerical investigation of powder dispersion mechanisms in Turbuhaler and the contact electrification effect. ADV POWDER TECHNOL 2022. [DOI: 10.1016/j.apt.2022.103839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
4
|
Capsule-Based Dry Powder Inhaler Evaluation Using CFD-DEM Simulations and Next Generation Impactor Data. Eur J Pharm Sci 2022; 175:106226. [DOI: 10.1016/j.ejps.2022.106226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 05/03/2022] [Accepted: 05/23/2022] [Indexed: 11/24/2022]
|
5
|
Benque B, Khinast JG. Carrier particle emission and dispersion in transient CFD-DEM simulations of a capsule-based DPI. Eur J Pharm Sci 2021; 168:106073. [PMID: 34774996 DOI: 10.1016/j.ejps.2021.106073] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/26/2021] [Accepted: 11/09/2021] [Indexed: 11/25/2022]
Abstract
The dispersion of carrier-based formulations in capsule-based dry powder inhalers depends on several factors, including the patient's inhalation profile and the motion of capsule within the device. In the present study, coupled computational fluid dynamics and discrete element method simulations of a polydisperse cohesive lactose carrier in an Aerolizer® inhaler were conducted at a constant flow rate of 100 L/min and considering an inhalation profile of asthmatic children between 5 and 17 years approximated from literature data. In relevant high-speed photography experiments, it was observed that the powder was distributed to both capsule ends before being ejected from the capsule. Several methods of ensuring similar behavior in the simulations were presented. Both the constant flow rate simulation and the profile simulations showed a high powder retention in the capsule (7.37-19.00%). Although the inhaler retention was negligible in the constant flow rate simulation due to consistently high air velocities in the device, it reached values of around 7% in most of the profile simulations. In all simulations, some of the carrier powder was ejected from the capsule as particle clusters. These clusters were larger in the profile simulation than in the constant flow rate simulation. Of the powder discharged from the capsule, a high percentage was bound in clusters in the profile simulation in the beginning and at the end of the inhalation profile while no more than 10% of the powder ejected from the capsule in the 100 L/min constant flow rate simulation were in clusters at any time. The powder emission from the capsule was studied, indicating a strong dependency of the powder mass flow from the capsule on the angular capsule position. When the capsule holes face the inhaler's air inlets, the air flow into the capsule restricts the powder discharge. The presented results provide a detailed view of some aspects of the powder flow and dispersion of a cohesive carrier in a capsule-based inhaler device. Furthermore, the importance of considering inhalation profiles in addition to conventional constant flow rate simulations was confirmed.
Collapse
Affiliation(s)
- Benedict Benque
- Institute of Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria; Research Center Pharmaceutical Engineering, Inffeldgasse 13, 8010 Graz, Austria
| | - Johannes G Khinast
- Institute of Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria; Research Center Pharmaceutical Engineering, Inffeldgasse 13, 8010 Graz, Austria.
| |
Collapse
|
6
|
Comparative Assessment of In Vitro and In Silico Methods for Aerodynamic Characterization of Powders for Inhalation. Pharmaceutics 2021; 13:pharmaceutics13111831. [PMID: 34834247 PMCID: PMC8619946 DOI: 10.3390/pharmaceutics13111831] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 10/25/2021] [Accepted: 10/28/2021] [Indexed: 11/16/2022] Open
Abstract
In vitro assessment of dry powders for inhalation (DPIs) aerodynamic performance is an inevitable test in DPI development. However, contemporary trends in drug development also implicate the use of in silico methods, e.g., computational fluid dynamics (CFD) coupled with discrete phase modeling (DPM). The aim of this study was to compare the designed CFD-DPM outcomes with the results of three in vitro methods for aerodynamic assessment of solid lipid microparticle DPIs. The model was able to simulate particle-to-wall sticking and estimate fractions of particles that stick or bounce off the inhaler's wall; however, we observed notable differences between the in silico and in vitro results. The predicted emitted fractions (EFs) were comparable to the in vitro determined EFs, whereas the predicted fine particle fractions (FPFs) were generally lower than the corresponding in vitro values. In addition, CFD-DPM predicted higher mass median aerodynamic diameter (MMAD) in comparison to the in vitro values. The outcomes of different in vitro methods also diverged, implying that these methods are not interchangeable. Overall, our results support the utility of CFD-DPM in the DPI development, but highlight the need for additional improvements in these models to capture all the key processes influencing aerodynamic performance of specific DPIs.
Collapse
|
7
|
Alfano FO, Benassi A, Gaspari R, Di Renzo A, Di Maio FP. Full-Scale DEM Simulation of Coupled Fluid and Dry-Coated Particle Flow in Swirl-Based Dry Powder Inhalers. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c02864] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
| | - Andrea Benassi
- DP Manufacturing & Innovation, Chiesi Farmaceutici SpA, 43122 Parma, Italy
- International School for Advanced Studies (SISSA), 34136 Trieste, Italy
| | - Roberto Gaspari
- DP Manufacturing & Innovation, Chiesi Farmaceutici SpA, 43122 Parma, Italy
| | | | | |
Collapse
|
8
|
Fletcher DF, Chaugule V, Gomes Dos Reis L, Young PM, Traini D, Soria J. On the Use of Computational Fluid Dynamics (CFD) Modelling to Design Improved Dry Powder Inhalers. Pharm Res 2021; 38:277-288. [PMID: 33575958 DOI: 10.1007/s11095-020-02981-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 12/22/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE Computational Fluid Dynamics (CFD) simulations are performed to investigate the impact of adding a grid to a two-inlet dry powder inhaler (DPI). The purpose of the paper is to show the importance of the correct choice of closure model and modeling approach, as well as to perform validation against particle dispersion data obtained from in-vitro studies and flow velocity data obtained from particle image velocimetry (PIV) experiments. METHODS CFD simulations are performed using the Ansys Fluent 2020R1 software package. Two RANS turbulence models (realisable k - ε and k - ω SST) and the Stress Blended Eddy Simulation (SBES) models are considered. Lagrangian particle tracking for both carrier and fine particles is also performed. RESULTS Excellent comparison with the PIV data is found for the SBES approach and the particle tracking data are consistent with the dispersion results, given the simplicity of the assumptions made. CONCLUSIONS This work shows the importance of selecting the correct turbulence modelling approach and boundary conditions to obtain good agreement with PIV data for the flow-field exiting the device. With this validated, the model can be used with much higher confidence to explore the fluid and particle dynamics within the device.
Collapse
Affiliation(s)
- David F Fletcher
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia
| | - Vishal Chaugule
- Laboratory for Turbulence Research in Aerospace and Combustion (LTRAC), Department of Mechanical and Aerospace Engineering, Monash University, Clayton Campus, Melbourne, Australia.
| | - Larissa Gomes Dos Reis
- Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Paul M Young
- Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Daniela Traini
- Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Julio Soria
- Laboratory for Turbulence Research in Aerospace and Combustion (LTRAC), Department of Mechanical and Aerospace Engineering, Monash University, Clayton Campus, Melbourne, Australia
| |
Collapse
|
9
|
Zheng Z, Leung SSY, Gupta R. Flow and Particle Modelling of Dry Powder Inhalers: Methodologies, Recent Development and Emerging Applications. Pharmaceutics 2021; 13:189. [PMID: 33535512 PMCID: PMC7912775 DOI: 10.3390/pharmaceutics13020189] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/22/2021] [Accepted: 01/27/2021] [Indexed: 11/16/2022] Open
Abstract
Dry powder inhaler (DPI) is a device used to deliver a drug in dry powder form to the lungs. A wide range of DPI products is currently available, with the choice of DPI device largely depending on the dose, dosing frequency and powder properties of formulations. Computational fluid dynamics (CFD), together with various particle motion modelling tools, such as discrete particle methods (DPM) and discrete element methods (DEM), have been increasingly used to optimise DPI design by revealing the details of flow patterns, particle trajectories, de-agglomerations and depositions within the device and the delivery paths. This review article focuses on the development of the modelling methodologies of flow and particle behaviours in DPI devices and their applications to device design in several emerging fields. Various modelling methods, including the most recent multi-scale approaches, are covered and the latest simulation studies of different devices are summarised and critically assessed. The potential and effectiveness of the modelling tools in optimising designs of emerging DPI devices are specifically discussed, such as those with the features of high-dose, pediatric patient compatibility and independency of patients' inhalation manoeuvres. Lastly, we summarise the challenges that remain to be addressed in DPI-related fluid and particle modelling and provide our thoughts on future research direction in this field.
Collapse
Affiliation(s)
- Zhanying Zheng
- Center for Turbulence Control, Harbin Institute of Technology, Shenzhen 518055, China
| | - Sharon Shui Yee Leung
- School of Pharmacy, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong;
| | - Raghvendra Gupta
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India;
| |
Collapse
|
10
|
Benque B, Khinast JG. Estimating inter-patient variability of dispersion in dry powder inhalers using CFD-DEM simulations. Eur J Pharm Sci 2021; 156:105574. [PMID: 32980431 DOI: 10.1016/j.ejps.2020.105574] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 07/28/2020] [Accepted: 09/23/2020] [Indexed: 10/23/2022]
Abstract
Drug delivery from a capsule-based dry powder inhaler depends on the inhaler's design, the drug's formulation, and the inhalation maneuver. The latter affects both the air flow and the capsule motion in the inhaler. It is well known that patient-to-patient variability is a major challenge in the design of new inhaler types. Modeling and simulation are important tools for understanding such systems, yet quite complex. Simulation studies of capsule-based dry powder inhalers have disregarded the transient nature of the inhalation process, adopting a constant flow rate through the inhaler instead. In addition, either no capsules, a capsule in a fixed position, or a capsule rotating at a constant rate have been considered. In this work, literature data for three inhalation flow profiles were incorporated into coupled simulations of the air flow and carrier particle motion through an Aerolizer® dry powder inhaler with a rotating capsule and compared to simulations at constant air flow rates. The results for the profile simulations indicated that the carrier powder experienced larger velocity fluctuations. Acceleration events were tracked as a measure of collision- and flow-induced dispersion. The majority of fast particle accelerations occurred when the particles collided with the swirl chamber walls. Of the two common particle dispersion metrics, only the peak particle force distribution appeared to be sensitive to the inhalation profiles, while the effect of the profiles on the cumulative impulse was small.
Collapse
Affiliation(s)
- Benedict Benque
- Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| | - Johannes G Khinast
- Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria; Research Center for Pharmaceutical Engineering, Inffeldgasse 13, 8010 Graz, Austria.
| |
Collapse
|
11
|
Walenga RL, Babiskin AH, Zhao L. In Silico Methods for Development of Generic Drug-Device Combination Orally Inhaled Drug Products. CPT-PHARMACOMETRICS & SYSTEMS PHARMACOLOGY 2019; 8:359-370. [PMID: 31044532 PMCID: PMC6618094 DOI: 10.1002/psp4.12413] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 04/07/2019] [Indexed: 12/03/2022]
Abstract
The development of generic, single‐entity, drug–device combination products for orally inhaled drug products is challenging in part because of the complex nature of device design characteristics and the difficulties associated with establishing bioequivalence for a locally acting drug product delivered to the site of action in the lung. This review examines in silico models that may be used to support the development of generic orally inhaled drug products and how model credibility may be assessed.
Collapse
Affiliation(s)
- Ross L Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Andrew H Babiskin
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Liang Zhao
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
12
|
Potential and constraints for the application of CFD combined with Lagrangian particle tracking to dry powder inhalers. Eur J Pharm Sci 2019; 128:299-324. [DOI: 10.1016/j.ejps.2018.12.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 11/19/2018] [Accepted: 12/10/2018] [Indexed: 11/19/2022]
|
13
|
Lee HJ, Kwon IH, Lee HG, Kwon YB, Woo HM, Cho SM, Choi YW, Chon J, Kim K, Kim DW, Park CW. Spiral mouthpiece design in a dry powder inhaler to improve aerosolization. Int J Pharm 2018; 553:149-156. [DOI: 10.1016/j.ijpharm.2018.10.036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 09/30/2018] [Accepted: 10/14/2018] [Indexed: 10/28/2022]
|
14
|
Das P, Nof E, Amirav I, Kassinos SC, Sznitman J. Targeting inhaled aerosol delivery to upper airways in children: Insight from computational fluid dynamics (CFD). PLoS One 2018; 13:e0207711. [PMID: 30458054 PMCID: PMC6245749 DOI: 10.1371/journal.pone.0207711] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 11/03/2018] [Indexed: 11/28/2022] Open
Abstract
Despite the prevalence of inhalation therapy in the treatment of pediatric respiratory disorders, most prominently asthma, the fraction of inhaled drugs reaching the lungs for maximal efficacy remains adversely low. By and large drug delivery devices and their inhalation guidelines are typically derived from adult studies with child dosages adapted according to body weight. While it has long been recognized that physiological (e.g. airway sizes, breathing maneuvers) and physical transport (e.g. aerosol dynamics) characteristics are critical in governing deposition outcomes, such knowledge has yet to be extensively adapted to younger populations. Motivated by such shortcomings, the present work leverages in a first step in silico computational fluid dynamics (CFD) to explore opportunities for augmenting aerosol deposition in children based on respiratory physiological and physical transport determinants. Using an idealized, anatomically-faithful upper airway geometry, airflow and aerosol motion are simulated as a function of age, spanning a five year old to an adult. Breathing conditions mimic realistic age-specific inhalation maneuvers representative of Dry Powder Inhalers (DPI) and nebulizer inhalation. Our findings point to the existence of a single dimensionless curve governing deposition in the conductive airways via the dimensionless Stokes number (Stk). Most significantly, we uncover the existence of a distinct deposition peak irrespective of age. For the DPI simulations, this peak (∼ 80%) occurs at Stk ≈ 0.06 whereas for nebulizer simulations, the corresponding peak (∼ 45%) occurs in the range of Stk between 0.03-0.04. Such dimensionless findings hence translate to an optimal window of micron-sized aerosols that evolves with age and varies with inhalation device. The existence of such deposition optima advocates revisiting design guidelines for optimizing deposition outcomes in pediatric inhalation therapy.
Collapse
Affiliation(s)
- Prashant Das
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Eliram Nof
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Israel Amirav
- Department of Pediatrics, Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Stavros C. Kassinos
- Computational Sciences Laboratory (UCY-CompSci), Department of Mechanical and Manufacturing Engineering, University of Cyprus, Kallipoleos Avenue 75, Nicosia 1678, Cyprus
| | - Josué Sznitman
- Department of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
15
|
Ariane M, Sommerfeld M, Alexiadis A. Wall collision and drug-carrier detachment in dry powder inhalers: Using DEM to devise a sub-scale model for CFD calculations. POWDER TECHNOL 2018. [DOI: 10.1016/j.powtec.2018.04.051] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
16
|
Lee HJ, Lee HG, Kwon YB, Kim JY, Rhee YS, Chon J, Park ES, Kim DW, Park CW. The role of lactose carrier on the powder behavior and aerodynamic performance of bosentan microparticles for dry powder inhalation. Eur J Pharm Sci 2018; 117:279-289. [DOI: 10.1016/j.ejps.2018.03.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 01/31/2018] [Accepted: 03/02/2018] [Indexed: 10/17/2022]
|
17
|
Coupled in silico platform: Computational fluid dynamics (CFD) and physiologically-based pharmacokinetic (PBPK) modelling. Eur J Pharm Sci 2018; 113:171-184. [DOI: 10.1016/j.ejps.2017.10.022] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 10/11/2017] [Accepted: 10/14/2017] [Indexed: 01/05/2023]
|
18
|
Kopsch T, Murnane D, Symons D. A personalized medicine approach to the design of dry powder inhalers: Selecting the optimal amount of bypass. Int J Pharm 2018; 529:589-596. [PMID: 28743094 DOI: 10.1016/j.ijpharm.2017.07.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 06/29/2017] [Accepted: 07/01/2017] [Indexed: 11/29/2022]
Abstract
In dry powder inhalers (DPIs) the patient's inhalation manoeuvre strongly influences the release of drug. Drug release from a DPI may also be influenced by the size of any air bypass incorporated in the device. If the amount of bypass is high less air flows through the entrainment geometry and the release rate is lower. In this study we propose to reduce the intra- and inter-patient variations of drug release by controlling the amount of air bypass in a DPI. A fast computational method is proposed that can predict how much bypass is needed for a specified drug delivery rate for a particular patient. This method uses a meta-model which was constructed using multiphase computational fluid dynamic (CFD) simulations. The meta-model is applied in an optimization framework to predict the required amount of bypass needed for drug delivery that is similar to a desired target release behaviour. The meta-model was successfully validated by comparing its predictions to results from additional CFD simulations. The optimization framework has been applied to identify the optimal amount of bypass needed for fictitious sample inhalation manoeuvres in order to deliver a target powder release profile for two patients.
Collapse
Affiliation(s)
- Thomas Kopsch
- University of Cambridge, Department of Engineering, Trumpington Street, CB2 1PZ, UK.
| | - Darragh Murnane
- University of Hertfordshire, Department of Pharmacy, Pharmacology and Postgraduate Medicine, College Lane, AL10 9AB, UK
| | - Digby Symons
- University of Canterbury, Mechanical Engineering Department, Christchurch 8140, New Zealand
| |
Collapse
|
19
|
Djuris J, Djuric Z. Modeling in the quality by design environment: Regulatory requirements and recommendations for design space and control strategy appointment. Int J Pharm 2017; 533:346-356. [PMID: 28579542 DOI: 10.1016/j.ijpharm.2017.05.070] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Revised: 05/19/2017] [Accepted: 05/29/2017] [Indexed: 12/23/2022]
Abstract
Mathematical models can be used as an integral part of the quality by design (QbD) concept throughout the product lifecycle for variety of purposes, including appointment of the design space and control strategy, continual improvement and risk assessment. Examples of different mathematical modeling techniques (mechanistic, empirical and hybrid) in the pharmaceutical development and process monitoring or control are provided in the presented review. In the QbD context, mathematical models are predominantly used to support design space and/or control strategies. Considering their impact to the final product quality, models can be divided into the following categories: high, medium and low impact models. Although there are regulatory guidelines on the topic of modeling applications, review of QbD-based submission containing modeling elements revealed concerns regarding the scale-dependency of design spaces and verification of models predictions at commercial scale of manufacturing, especially regarding real-time release (RTR) models. Authors provide critical overview on the good modeling practices and introduce concepts of multiple-unit, adaptive and dynamic design space, multivariate specifications and methods for process uncertainty analysis. RTR specification with mathematical model and different approaches to multivariate statistical process control supporting process analytical technologies are also presented.
Collapse
Affiliation(s)
- Jelena Djuris
- Department of Pharmaceutical Technology and Cosmetology, University of Belgrade, Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia.
| | - Zorica Djuric
- Department of Pharmaceutical Technology and Cosmetology, University of Belgrade, Faculty of Pharmacy, Vojvode Stepe 450, 11221 Belgrade, Serbia
| |
Collapse
|
20
|
Optimization of a DPI Inhaler: A Computational Approach. J Pharm Sci 2017; 106:850-858. [DOI: 10.1016/j.xphs.2016.11.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 11/02/2016] [Accepted: 11/08/2016] [Indexed: 11/20/2022]
|