1
|
Zhu X, Punia A, Skomski D, Su Y, Shultz CS, Giles MB, Rudd ND, Raman N, Koynov A, Lamm MS. Insights into Factors Affecting Ethylene-Vinyl Acetate Copolymer Crystallinity in Islatravir Implant. Mol Pharm 2024; 21:1933-1941. [PMID: 38502549 DOI: 10.1021/acs.molpharmaceut.3c01198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
Islatravir, a highly potent nucleoside reverse transcriptase translocation inhibitor (NRTTI) for the treatment of HIV, has great potential to be formulated as ethylene-vinyl acetate (EVA) copolymer-based implants via hot melt extrusion. The crystallinity of EVA determines its physical and rheological properties and may impact the drug-eluting implant performance. Herein, we describe the systematic analysis of factors affecting the EVA crystallinity in islatravir implants. Differential scanning calorimetry (DSC) on EVA and solid-state NMR revealed drug loading promoted EVA crystallization, whereas BaSO4 loading had negligible impact on EVA crystallinity. The sterilization through γ-irradiation appeared to significantly impact the EVA crystallinity and surface characteristics of the implants. Furthermore, DSC analysis of thin implant slices prepared with an ultramicrotome indicated that the surface layer of the implant was more crystalline than the core. These findings provide critical insights into factors affecting the crystallinity, mechanical properties, and physicochemical properties of the EVA polymer matrix of extruded islatravir implants.
Collapse
Affiliation(s)
- Xiaolong Zhu
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Ashish Punia
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Daniel Skomski
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Yongchao Su
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - C Scott Shultz
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Morgan B Giles
- Pharmaceutical Sciences and Clinical Supply, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Nathan D Rudd
- Pharmaceutical Sciences and Clinical Supply, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Nisha Raman
- Pharmaceutical Sciences and Clinical Supply, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Athanas Koynov
- Pharmaceutical Sciences and Clinical Supply, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Matthew S Lamm
- Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| |
Collapse
|
2
|
Magill E, Demartis S, Gavini E, Permana AD, Thakur RRS, Adrianto MF, Waite D, Glover K, Picco CJ, Korelidou A, Detamornrat U, Vora LK, Li L, Anjani QK, Donnelly RF, Domínguez-Robles J, Larrañeta E. Solid implantable devices for sustained drug delivery. Adv Drug Deliv Rev 2023; 199:114950. [PMID: 37295560 DOI: 10.1016/j.addr.2023.114950] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 06/02/2023] [Accepted: 06/04/2023] [Indexed: 06/12/2023]
Abstract
Implantable drug delivery systems (IDDS) are an attractive alternative to conventional drug administration routes. Oral and injectable drug administration are the most common routes for drug delivery providing peaks of drug concentrations in blood after administration followed by concentration decay after a few hours. Therefore, constant drug administration is required to keep drug levels within the therapeutic window of the drug. Moreover, oral drug delivery presents alternative challenges due to drug degradation within the gastrointestinal tract or first pass metabolism. IDDS can be used to provide sustained drug delivery for prolonged periods of time. The use of this type of systems is especially interesting for the treatment of chronic conditions where patient adherence to conventional treatments can be challenging. These systems are normally used for systemic drug delivery. However, IDDS can be used for localised administration to maximise the amount of drug delivered within the active site while reducing systemic exposure. This review will cover current applications of IDDS focusing on the materials used to prepare this type of systems and the main therapeutic areas of application.
Collapse
Affiliation(s)
- Elizabeth Magill
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Sara Demartis
- Department of Chemical, Physical, Mathematical and Natural Sciences, University of Sassari, Sassari, 07100, Italy
| | - Elisabetta Gavini
- Department of Medicine, Surgery and Pharmacy, University of Sassari, Sassari, 07100, Italy
| | - Andi Dian Permana
- Department of Pharmaceutics, Faculty of Pharmacy, Universitas Hasanuddin, Makassar 90245, Indonesia
| | - Raghu Raj Singh Thakur
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK; Re-Vana Therapeutics, McClay Research Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Muhammad Faris Adrianto
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK; Re-Vana Therapeutics, McClay Research Centre, 97 Lisburn Road, Belfast BT9 7BL, UK; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Airlangga University, Surabaya, East Java 60115, Indonesia
| | - David Waite
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK; Re-Vana Therapeutics, McClay Research Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Katie Glover
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Camila J Picco
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Anna Korelidou
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Usanee Detamornrat
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Lalitkumar K Vora
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Linlin Li
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK; Fakultas Farmasi, Universitas Megarezky, Jl. Antang Raya No. 43, Makassar 90234, Indonesia
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK
| | - Juan Domínguez-Robles
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK; Department of Pharmacy and Pharmaceutical Technology, Faculty of Pharmacy, Universidad de Sevilla, 41012 Seville, Spain.
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, 97, Lisburn Road, Belfast BT9 7BL, UK.
| |
Collapse
|
3
|
Controlled delivery via hot-melt extrusion: A focus on non-biodegradable carriers for non-oral applications. J Drug Deliv Sci Technol 2023. [DOI: 10.1016/j.jddst.2023.104289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
4
|
Matić J, Stanković-Brandl M, Bauer H, Lovey J, Martel S, Herkenne C, Paudel A, Khinast J. Pharmaceutical hot melt extrusion process development using QbD and digital twins. Int J Pharm 2023; 631:122469. [PMID: 36509223 DOI: 10.1016/j.ijpharm.2022.122469] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 11/28/2022] [Accepted: 12/04/2022] [Indexed: 12/14/2022]
Abstract
Pharmaceutical product development guided by Quality by Design (QbD) is based on a complete understanding of the critical process parameters (CPPs) that are important for achieving the desired product critical quality attributes (CQAs). The effect of process settings, such as the screw speed, the throughput, the barrel temperature, and the screw configuration, is a well-known factor in the setup of pharmaceutical hot melt extrusion (HME) processes. A CPP that has not yet been extensively researched is the type of cross-section geometry of the screw elements. Typically, pharmaceutical extruders have double-flighted screw cross-sections, with some elements having a single- or triple-flighted element section. The exception is a NANO16 extruder from Leistritz, with all screw elements having a triple-flighted screw geometry. We investigated the process setup and scale-up to a double-flighted extruder experimentally and in silico via a digital twin. Two formulations were processed on a NANO16 extruder and virtually transferred to a ZSE18 double-flighted co-rotating twin-screw extruder. Detailed smoothed particle hydrodynamics simulations of all screw elements available from both extruders were performed, and their efficiency in conveying, pressure build-up, and power consumption were studied. Reduced-order 1D HME simulations, which were carried out to investigate the process space and scalability of both extruders, were experimentally validated.
Collapse
Affiliation(s)
- Josip Matić
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
| | | | - Hannes Bauer
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Jessica Lovey
- Debiopharm Research and Manufacturing, Rue du Levant 146, 1920 Martigny, Switzerland
| | - Sophie Martel
- Debiopharm Research and Manufacturing, Rue du Levant 146, 1920 Martigny, Switzerland
| | - Christophe Herkenne
- Debiopharm Research and Manufacturing, Rue du Levant 146, 1920 Martigny, Switzerland
| | - Amrit Paudel
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| | - Johannes Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| |
Collapse
|
5
|
Eder S, Wiltschko L, Koutsamanis I, Alberto Afonso Urich J, Arbeiter F, Roblegg E, Spoerk M. Toward a new generation of vaginal pessaries via 3D-printing: concomitant mechanical support and drug delivery. Eur J Pharm Biopharm 2022; 174:77-89. [PMID: 35390451 DOI: 10.1016/j.ejpb.2022.04.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 04/01/2022] [Accepted: 04/01/2022] [Indexed: 11/04/2022]
Abstract
To improve patient adherence, vaginal pessaries - polymeric structures providing mechanical support to treat stress urinary incontinence (SUI) - greatly benefit from 3D-printing through customization of their mechanics, e.g. infill modifications. However, currently only limited polymers provide both flawless printability and controlled drug release. The current study closes this gap by exploring 3D-printing, more specifically fused filament fabrication, of pharmaceutical grade thermoplastic polyurethanes (TPU) of different hardness and hydrophilicity into complex pessary structures. Next to the pessary mechanics, drug incorporation into such a device was addressed for the first time. Mechanically, the soft hydrophobic TPU was the most promising candidate for pessary customization, as pessaries made thereof covered a broad range of the key mechanical parameter, while allowing self-insertion. From the drug release point of view, the hydrophobic TPUs were superior over the hydrophilic one, as the release levels of the model drug acyclovir were closer to the target value. Summarizing, the fabrication of TPU-based pessaries via 3D-printing is an innovative strategy to create a customized pessary combination product that simultaneously provides mechanical support and pharmacological therapy.
Collapse
Affiliation(s)
- Simone Eder
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
| | - Laura Wiltschko
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Ioannis Koutsamanis
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | | | - Florian Arbeiter
- Materials Science and Testing of Polymers, Montanuniversitaet Leoben, Otto Gloeckel-Straße 2, 8700 Leoben, Austria
| | - Eva Roblegg
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute of Pharmaceutical Sciences, Department of Pharmaceutical Technology, University of Graz, Universitätsplatz 1, 8010 Graz
| | - Martin Spoerk
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
| |
Collapse
|
6
|
Rafiei F, Tabesh H, Farzad S, Farzaneh F, Rezaei M, Hosseinzade F, Mottaghy K. Development of Hormonal Intravaginal Rings: Technology and Challenges. Geburtshilfe Frauenheilkd 2021; 81:789-806. [PMID: 34276064 PMCID: PMC8277443 DOI: 10.1055/a-1369-9395] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 01/20/2021] [Indexed: 12/24/2022] Open
Abstract
Intravaginal rings (IVRs) are minimally invasive polymeric devices specifically designed to be used for the sustained and prolonged release of various type of drugs such as hormones. One of the benefits of using topical drug delivery systems (e.g., IVRs) is the fact that systemic drug delivery may cause drug resistance due to elevated drug levels. Topical drug delivery also provides higher concentrations of the drug to the target site and has fewer side effects. In addition, when a drug is administered vaginally, the hepatic first-pass effect is avoided, resulting in higher absorption. Contraception and treatments for specific diseases such as endometriosis and hormone deficiencies can be improved by the administration of hormones via an IVR. This article aims to classify and compare various designs of commercially available and non-commercial hormonal IVRs and to analyze their performance. Current challenges affecting the development of IVRs are investigated, and
proposed solutions are discussed. A comprehensive search of publications in MEDLINE/PubMed and of commercial product data of IVRs was performed, and the materials, designs, performance, and applications (e.g., contraception, endometriosis, estrogen deficiency and urogenital atrophy) of hormonal IVRs were thoroughly evaluated. Most hormonal IVRs administer female sex hormones, i.e., estrogen and progestogens. In terms of material, IVRs are divided into 3 main groups: silicone, polyurethane, and polyethylene-co-vinyl acetate IVRs. As regards their design, there are 4 major designs for IVRs which strongly affect their performance and the timing and rate of hormone release. Important challenges include reducing the burst release and maintaining the bioavailability of hormones at their site of action over a prolonged period of administration as well as lowering production costs. Hormonal IVRs are a promising method which could be used to facilitate combination therapies by
administering multiple drugs in a single IVR while eliminating the side effects of conventional drug administration methods. IVRs could considerably improve womenʼs quality of life all over the world within a short period of time.
Collapse
Affiliation(s)
- Fojan Rafiei
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Hadi Tabesh
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Shayan Farzad
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, United States
| | - Farah Farzaneh
- Preventative Gynecology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Rezaei
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Fateme Hosseinzade
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Khosrow Mottaghy
- Institute of Physiology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
7
|
Matić J, Alva C, Eder S, Reusch K, Paudel A, Khinast J. Towards predicting the product quality in hot-melt extrusion: Pilot plant scale extrusion. INTERNATIONAL JOURNAL OF PHARMACEUTICS-X 2021; 3:100084. [PMID: 34159312 PMCID: PMC8193368 DOI: 10.1016/j.ijpx.2021.100084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 05/17/2021] [Indexed: 11/25/2022]
Abstract
Following our study on the impact of hot melt extrusion (HME) process conditions on the product quality, we expanded our investigation to assessing the effect of scale-up on the product quality. To this end, we studied the influence of process settings and different scale-up variants on the active pharmaceutical ingredient (API) degradation in a pilot plant scale extruder. Six scale-up variants were investigated and none of them could replicate the product quality from the original process setup on a lab-scale extruder. By analyzing several process-dependent and -independent variables and cross referencing them to the experiments in the lab-scale extruder, we identified certain patterns. The results of the reduced order mechanistic 1D HME simulation of various process states made it possible to establish a correlation between the achieved API degradation and the local melt temperature and the exposure time in specific zones along the screw configuration. Since the same melt temperature and exposure time correlations were also valid for the lab scale-extruder, such an approach could be used in the future to predict the product quality as a function of processing conditions fully in silico prior to the first extrusion trials.
Collapse
Affiliation(s)
- Josip Matić
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Carolina Alva
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Simone Eder
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Kathrin Reusch
- Leistritz Pharma Extrusion, Markgrafenstraße. 29-39 1, 90459 Nürnberg, Germany
| | - Amrit Paudel
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.,Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| | - Johannes Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.,Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| |
Collapse
|
8
|
|
9
|
Koutsamanis I, Paudel A, Alva Zúñiga CP, Wiltschko L, Spoerk M. Novel polyester-based thermoplastic elastomers for 3D-printed long-acting drug delivery applications. J Control Release 2021; 335:290-305. [PMID: 34044092 DOI: 10.1016/j.jconrel.2021.05.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 05/08/2021] [Accepted: 05/21/2021] [Indexed: 12/31/2022]
Abstract
To improve patient compliance and personalised drug delivery, long-acting drug delivery devices (LADDDs), such as implants and inserts, greatly benefit from a customisation in their shape through the emerging 3D-printing technology, since their production usually follows a one-size-fits-most approach. The use of 3D-printing for LADDDs, however, is mainly limited by the shortage of flawlessly 3D-printable, yet biocompatible materials. The present study tackles this issue by introducing a novel, non-biodegradable material, namely a polyester-based thermoplastic elastomer (TPC) - a multi-block copolymer containing alternating semi-crystalline polybutylene terephthalate hard segments and poly-ether-terephthalate amorphous soft segments. Next to a detailed description of the material's 3D-printability by mechanical, rheological and thermal analyses, which was found to be superior to that of conventional polymers (ethylene-vinyl acetates (EVA)), this study establishes the fundamental understandings of the interactions between progesterone (P4) and TPC and drug-releasing properties of TPC for the first time. P4-loaded LADDDs based on TPC, prepared via an elaborated solvent-immersion technique, enable the release of P4 at pharmacologically relevant rates, similar to those of marketed formulations based on EVA and silicones. Additionally, TPC demonstrated an exceptional 3D-printability for a wide selection of implant sizes and complex geometries.
Collapse
Affiliation(s)
- Ioannis Koutsamanis
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Amrit Paudel
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute of Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria.
| | | | - Laura Wiltschko
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Martin Spoerk
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
| |
Collapse
|
10
|
Carson L, Merkatz R, Martinelli E, Boyd P, Variano B, Sallent T, Malcolm RK. The Vaginal Microbiota, Bacterial Biofilms and Polymeric Drug-Releasing Vaginal Rings. Pharmaceutics 2021; 13:pharmaceutics13050751. [PMID: 34069590 PMCID: PMC8161251 DOI: 10.3390/pharmaceutics13050751] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 05/14/2021] [Accepted: 05/18/2021] [Indexed: 12/26/2022] Open
Abstract
The diversity and dynamics of the microbial species populating the human vagina are increasingly understood to play a pivotal role in vaginal health. However, our knowledge about the potential interactions between the vaginal microbiota and vaginally administered drug delivery systems is still rather limited. Several drug-releasing vaginal ring products are currently marketed for hormonal contraception and estrogen replacement therapy, and many others are in preclinical and clinical development for these and other clinical indications. As with all implantable polymeric devices, drug-releasing vaginal rings are subject to surface bacterial adherence and biofilm formation, mostly associated with endogenous microorganisms present in the vagina. Despite more than 50 years since the vaginal ring concept was first described, there has been only limited study and reporting around bacterial adherence and biofilm formation on rings. With increasing interest in the vaginal microbiome and vaginal ring technology, this timely review article provides an overview of: (i) the vaginal microbiota, (ii) biofilm formation in the human vagina and its potential role in vaginal dysbiosis, (iii) mechanistic aspects of biofilm formation on polymeric surfaces, (iv) polymeric materials used in the manufacture of vaginal rings, (v) surface morphology characteristics of rings, (vi) biomass accumulation and biofilm formation on vaginal rings, and (vii) regulatory considerations.
Collapse
Affiliation(s)
- Louise Carson
- School of Pharmacy, Queen’s University Belfast, Belfast BT9 7BL, UK; (L.C.); (P.B.)
| | - Ruth Merkatz
- Population Council, One Dag Hammarskjold Plaza, New York, NY 10017, USA; (R.M.); (E.M.); (B.V.); (T.S.)
| | - Elena Martinelli
- Population Council, One Dag Hammarskjold Plaza, New York, NY 10017, USA; (R.M.); (E.M.); (B.V.); (T.S.)
| | - Peter Boyd
- School of Pharmacy, Queen’s University Belfast, Belfast BT9 7BL, UK; (L.C.); (P.B.)
| | - Bruce Variano
- Population Council, One Dag Hammarskjold Plaza, New York, NY 10017, USA; (R.M.); (E.M.); (B.V.); (T.S.)
| | - Teresa Sallent
- Population Council, One Dag Hammarskjold Plaza, New York, NY 10017, USA; (R.M.); (E.M.); (B.V.); (T.S.)
| | - Robert Karl Malcolm
- School of Pharmacy, Queen’s University Belfast, Belfast BT9 7BL, UK; (L.C.); (P.B.)
- Correspondence:
| |
Collapse
|
11
|
Forster SP, Dippold E, Chiang T. Twin-Screw Melt Granulation for Oral Solid Pharmaceutical Products. Pharmaceutics 2021; 13:pharmaceutics13050665. [PMID: 34066332 PMCID: PMC8148162 DOI: 10.3390/pharmaceutics13050665] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 04/23/2021] [Accepted: 04/27/2021] [Indexed: 12/16/2022] Open
Abstract
This article highlights the advantages of pharmaceutical continuous melt granulation by twin-screw extrusion. The different melt granulation process options and excipients are described and compared, and a case is made for expanded use of twin-screw melt granulation since it is a flexible and continuous process. Methods for binder selection are profiled with a focus on rheology and physical stability impacts. For twin-screw melt granulation, the mechanism of granulation and process impact on granule properties are described. Pharmaceutical applications of melt granulation ranging from immediate release of soluble and insoluble APIs, taste-masking, and sustained release formulation are reviewed, demonstrating the range of possibilities afforded by twin-screw melt granulation.
Collapse
|
12
|
Advances in controlled release hormonal technologies for contraception: A review of existing devices, underlying mechanisms, and future directions. J Control Release 2021; 330:797-811. [DOI: 10.1016/j.jconrel.2020.12.044] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 12/21/2020] [Accepted: 12/23/2020] [Indexed: 12/17/2022]
|
13
|
Koutsamanis I, Spoerk M, Arbeiter F, Eder S, Roblegg E. Development of Porous Polyurethane Implants Manufactured via Hot-Melt Extrusion. Polymers (Basel) 2020; 12:E2950. [PMID: 33321876 PMCID: PMC7764633 DOI: 10.3390/polym12122950] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 02/06/2023] Open
Abstract
Implantable drug delivery systems (IDDSs) offer good patient compliance and allow the controlled delivery of drugs over prolonged times. However, their application is limited due to the scarce material selection and the limited technological possibilities to achieve extended drug release. Porous structures are an alternative strategy that can overcome these shortcomings. The present work focuses on the development of porous IDDS based on hydrophilic (HPL) and hydrophobic (HPB) polyurethanes and chemical pore formers (PFs) manufactured by hot-melt extrusion. Different PF types and concentrations were investigated to gain a sound understanding in terms of extrudate density, porosity, compressive behavior, pore morphology and liquid uptake. Based on the rheological analyses, a stable extrusion process guaranteed porosities of up to 40% using NaHCO3 as PF. The average pore diameter was between 140 and 600 µm and was indirectly proportional to the concentration of PF. The liquid uptake of HPB was determined by the open pores, while for HPL both open and closed pores influenced the uptake. In summary, through the rational selection of the polymer type, the PF type and concentration, porous carrier systems can be produced continuously via extrusion, whose properties can be adapted to the respective application site.
Collapse
Affiliation(s)
- Ioannis Koutsamanis
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; (I.K.); (M.S.); (S.E.)
- Institute of Pharmaceutical Sciences, Pharmaceutical Technology and Biopharmacy, University of Graz, Universitaetsplatz 1, 8010 Graz, Austria
| | - Martin Spoerk
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; (I.K.); (M.S.); (S.E.)
| | - Florian Arbeiter
- Institute of Materials Science and Testing of Polymers, Montanuniversitaet Leoben, Otto Gloeckel-Straße 2, 8700 Leoben, Austria;
| | - Simone Eder
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; (I.K.); (M.S.); (S.E.)
| | - Eva Roblegg
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; (I.K.); (M.S.); (S.E.)
- Institute of Pharmaceutical Sciences, Pharmaceutical Technology and Biopharmacy, University of Graz, Universitaetsplatz 1, 8010 Graz, Austria
| |
Collapse
|
14
|
Matić J, Alva C, Witschnigg A, Eder S, Reusch K, Paudel A, Khinast J. Towards predicting the product quality in hot-melt extrusion: Small scale extrusion. INTERNATIONAL JOURNAL OF PHARMACEUTICS-X 2020; 2:100062. [PMID: 33299982 PMCID: PMC7704403 DOI: 10.1016/j.ijpx.2020.100062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 11/06/2020] [Accepted: 11/08/2020] [Indexed: 12/02/2022]
Abstract
In product development, it is crucial to choose the appropriate drug manufacturing route accurately and timely and to ensure that the technique selected is suitable for achieving the desired product quality. Guided by the QbD principles, the pharmaceutical industry is currently transitioning from batch to continuous manufacturing. In this context, process understanding and prediction are becoming even more important. With regard to hot melt extrusion, the process setup, optimization and scale-up in early stages of product development are particularly challenging due to poor process understanding, complex product-process relationship and a small amount of premix available for extensive experimental studies. Hence, automated, quick and reliable process setup and scale-up requires simulation tools that are accurate enough to capture the process and determine the product-process relationships. To this end, the effect of process settings on the degradation of the active pharmaceutical ingredient (API) in a lab-scale Leistritz ZSE12 extruder was investigated. As part of the presented study, the limitations of traditional process analysis using integral process values were investigated, together with the potential that simulations may have in predicting the process performance and the product quality. The results of our investigation indicate that the average melt temperatures and the exposure times in specific zones along the screw configuration correlate well with the API degradation values and can be used as potent process design criteria to simplify the process development.
Collapse
Affiliation(s)
- Josip Matić
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Carolina Alva
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Andreas Witschnigg
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Simone Eder
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria
| | - Kathrin Reusch
- Leistritz Pharma Extrusion, Markgrafenstraße, 29-39 1, 90459 Nürnberg, Germany
| | - Amrit Paudel
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.,Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| | - Johannes Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.,Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| |
Collapse
|
15
|
Novel Cleaning-in-Place Strategies for Pharmaceutical Hot Melt Extrusion. Pharmaceutics 2020; 12:pharmaceutics12060588. [PMID: 32599822 PMCID: PMC7356020 DOI: 10.3390/pharmaceutics12060588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 06/17/2020] [Accepted: 06/20/2020] [Indexed: 02/06/2023] Open
Abstract
To avoid any type of cross-contamination, residue-free production equipment is of utmost importance in the pharmaceutical industry. The equipment cleaning for continuous processes such as hot melt extrusion (HME), which has recently gained popularity in pharmaceutical applications, necessitates extensive manual labour and costs. The present work tackles the HME cleaning issue by investigating two cleaning strategies following the extrusion of polymeric formulations of a hormonal drug and for a sustained release formulation of a poorly soluble drug. First, an in-line quantification by means of UV–Vis spectroscopy was successfully implemented to assess very low active pharmaceutical ingredient (API) concentrations in the extrudates during a cleaning procedure for the first time. Secondly, a novel in-situ solvent-based cleaning approach was developed and its usability was evaluated and compared to a polymer-based cleaning sequence. Comparing the in-line data to typical swab and rinse tests of the process equipment indicated that inaccessible parts of the equipment were still contaminated after the polymer-based cleaning procedure, although no API was detected in the extrudate. Nevertheless, the novel solvent-based cleaning approach proved to be suitable for removing API residue from the majority of problematic equipment parts and can potentially enable a full API cleaning-in-place of a pharmaceutical extruder for the first time.
Collapse
|
16
|
Controlled-Release from High-Loaded Reservoir-Type Systems-A Case Study of Ethylene-Vinyl Acetate and Progesterone. Pharmaceutics 2020; 12:pharmaceutics12020103. [PMID: 32013050 PMCID: PMC7076478 DOI: 10.3390/pharmaceutics12020103] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 01/14/2020] [Accepted: 01/26/2020] [Indexed: 12/13/2022] Open
Abstract
Reservoir systems (drug-loaded core surrounded by drug-free membrane) provide long-term controlled drug release. This is especially beneficial for drug delivery to specific body regions including the vagina. In this study, we investigated the potential of reservoir systems to provide high drug release rates over several weeks. The considered model system was an intra-vaginal ring (IVR) delivering progesterone (P4) in the mg/day range using ethylene-vinyl acetate (EVA) as release rate-controlling polymers. To circumvent the high material needs associated with IVR manufacturing, we implemented a small-scale screening procedure that predicts the drug release from IVRs. Formulations were designed based on the solubility and diffusivity of P4 in EVAs with varying vinyl acetate content. High in-vitro P4 release was achieved by i) high P4 solubility in the core polymer; ii) high P4 partition coefficient between the membrane and the core; and/or iii) low membrane thicknesses. It was challenging for systems designed to release comparatively high fractions of P4 at early times to retain a constant drug release over a long time. P4 crystal dissolution in the core could not counterbalance drug diffusion through the membrane and drug crystal dissolution was found to be the rate-limiting step. Overall, high P4 release rates can be achieved from EVA-based reservoir systems.
Collapse
|
17
|
Dapivirine-releasing vaginal rings produced by plastic freeforming additive manufacturing. Int J Pharm 2019; 572:118725. [DOI: 10.1016/j.ijpharm.2019.118725] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 09/02/2019] [Accepted: 09/20/2019] [Indexed: 12/21/2022]
|