Chen S, Du T, Zhang H, Zhang Y, Qiao A. Advances in studies on tracheal stent design addressing the related complications. Mater Today Bio 2024; 29:101263. [PMID: 39399242 PMCID: PMC11467681 DOI: 10.1016/j.mtbio.2024.101263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 09/09/2024] [Accepted: 09/20/2024] [Indexed: 10/15/2024] Open
Abstract
Tracheal stents can be used to quickly reconstruct the airway and relieve symptoms of dyspnea in patients with tracheal stenosis. However, existing tracheal stents lead to complications such as granulation tissue formation, difficulty in removal, persistent growth of malignant tumors, stent migration, and mucus plugging. In this article, we reviewed the main methods used to reduce complications associated with tracheal stent design. Drug-eluting stents can inhibit granulation tissue formation and prevent infection and local chemotherapy. The biodegradable stent can support the trachea for some time, maintain tracheal patency, and degrade gradually, which avoids removing or replacing the stent. Radioactive stents loaded with I125 have good potential for inhibiting the persistent growth of malignant tumors. Three-dimensional printing technology enables the manufacturing of patient-specific stents, which increases the degree of matching between the complex tracheal anatomy and the stent, thus providing a new solution for stent migration caused by structural mismatch. Minimizing the barrier of the stent to mucociliary clearance, providing an anti-fouling coating, and culturing respiratory epithelial cells on the surface of the stent are the main methods used to reduce mucus plugging. We also proposed future research directions for tracheal stents to guide the design and manufacture of ideal tracheal stents.
Collapse
Affiliation(s)
- Shiliang Chen
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing University of Technology, Beijing, China
| | - Tianming Du
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing University of Technology, Beijing, China
| | - Hanbing Zhang
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing University of Technology, Beijing, China
| | - Yanping Zhang
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing University of Technology, Beijing, China
| | - Aike Qiao
- College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
- Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing University of Technology, Beijing, China
| |
Collapse
|
2
|
Stehlik L, Guha D, Anandakumar S, Taskova A, Vasakova MK. Biodegradable tracheal stents: our ten-year experience with adult patients. BMC Pulm Med 2024; 24:238. [PMID: 38750487 PMCID: PMC11094873 DOI: 10.1186/s12890-024-03057-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 05/08/2024] [Indexed: 05/18/2024] Open
Abstract
BACKGROUND Biodegradable (BD) stents made from polydioxanone have been used only in human airways. These stents combine the advantages of classical tracheal stents, and fewer side effects are expected due to their biocompatibility and their time-limited presence in airways. However, new clinical consequences have arisen. Here, the authors share their experiences with BD stents for tracheal indications, focusing on their safety and efficacy. METHODS This was a retrospective review of a collected database of adult patients who underwent implantation of biodegradable tracheal stents between September 2013 and December 2022 at the Department of Respiratory Medicine of the 1st Faculty of Medicine in Prague and Thomayer University Hospital. The indications included functionally significant nonmalignant tracheal stenosis and tracheomalacia. Self-expandable, biodegradable, polydioxanone tracheal stents manufactured by ELLA-CS Ltd. (Hradec Kralove, Czech Republic) were implanted during rigid bronchoscopy under general anaesthesia. All patients were followed up in the department and were provided with the necessary care. The main efficacy and safety parameters and relationships were analysed using descriptive statistics and Fisher´s exact, Wilcoxon and Kruskal‒Wallis tests. RESULTS A total of 65 stents were implanted in 47 adult patients. During the first two months after implantation, when adequate function was expected, the stent was found to be effective in 26 out of 39 patients who completed this period (66.7%). The clinical effectiveness reached 89.7%, as early restenoses were mostly mild and necessitated treatment in only 4 patients. The frequencies of significant mucostasis, migration and granulation tissue growth were 2.6%, 7.5% and 23.1%, respectively, during this period. Thirty-four participants completed the half-year follow-up period after the first or second stent insertion, and some were followed up beyond this period. Poor control of symptoms, the development of restenosis and the need for interventions were characteristic of this period as the stents degraded. Twenty-two patients who experienced remodelling or stabilization of the tracheal lumen achieved a stent-free state. Seven patients underwent subsequent surgical treatment. CONCLUSIONS BD stents are safe and provide adequate tracheal support until they begin to degrade. The use of BD stents necessitates close monitoring of patients and accurate treatment of possible restenosis. TRIAL REGISTRATION Based on project NT14146 - Biodegradable stents in the management of the large airways (2013-2015, MZ0/NT), registered on May 1, 2013, in the Research and Development and Innovation Information System of the Czech Republic and at ClinicalTrials.gov (reg. no. NCT02620319, December 2, 2015).
Collapse
Affiliation(s)
- Ludek Stehlik
- Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic.
| | - Debarya Guha
- Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
| | - Sheetal Anandakumar
- Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
| | - Alice Taskova
- Department of Thoracic Surgery, 3rd Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
| | - Martina Koziar Vasakova
- Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
| |
Collapse
|
3
|
Malik A, Ng VL, Sayed BA, Siddiqui A, Parra DA. Biodegradable biliary stents placement using a "kissing-stent" technique for management of a recalcitrant stricture post-live donor liver transplant. Pediatr Transplant 2024; 28:e14725. [PMID: 38436099 DOI: 10.1111/petr.14725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 02/10/2024] [Accepted: 02/13/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND Biliary complications are common in pediatric liver transplant. Strictures resistant to interventional radiology procedures can be extremely challenging to manage and may result in the need of surgery or retransplantation. METHODS This case report illustrates the use of biodegradable stents post left lateral segment live donor liver transplant in a pediatric patient with a recalcitrant chronic stricture of the biliary-enteric anastomosis. The patient developed a high stricture requiring multiple interventions and eventual access of both the segment II and segment III ducts of the graft. RESULTS To ensure adequate biliary drainage, two biodegradable stents were deployed using a "kissing-stent" technique. The stents were successfully deployed and allowed the patient to remain free from an internal-external biliary drain for 11 months, with eventual redeployment of an additional biodegradable stent. CONCLUSION In patients with recalcitrant stenosis of the biliary anastomosis, biodegradable stents may provide durable drainage, optimizing graft function and delaying retransplantation in addition to keeping patients without external devices, thus improving quality of life.
Collapse
Affiliation(s)
- Aleena Malik
- Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Vicky L Ng
- Division of Gastroenterology, Hepatology, and Nutrition, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Blayne A Sayed
- Division of General & Thoracic Surgery and Transplant and Regenerative Medicine Center, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Asad Siddiqui
- Department of Anesthesia and Pain Medicine, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Dimitri A Parra
- Division of Image Guided Therapy, Diagnostic and Interventional Radiology Department, The Hospital for Sick Children and Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
4
|
Minen F, Durward A, James P, Diamantopoulos A, Jogeesvaran H, Morgan GJ, Nyman A. Single-center review on safety of biodegradable airway stenting in pediatric population. Pediatr Pulmonol 2023; 58:3437-3446. [PMID: 37728230 DOI: 10.1002/ppul.26670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 07/12/2023] [Accepted: 08/12/2023] [Indexed: 09/21/2023]
Abstract
BACKGROUND Tracheobronchomalacia (TBM) and airway stenosis are recognized etiologies of airway obstruction among children. Their management is often challenging, requiring multiple interventions and prolonged respiratory support with associated long-term morbidity. Metallic or silicone stents have been used with mixed success and high complication rates. More recently biodegradable Ella stents (BES) provided an attractive interventional option. OBJECTIVES We report our experience in the treatment of TBM and vascular airway compression using BES. We deliberately downsized them to minimize intraluminal granulation tissue formation. MATERIALS AND METHODS Retrospective study over an 8-year period between November 2012 and December 2020 of pediatric patients with severe airway obstruction requiring airway stenting for extubation failure, malacic death spells, recurrent chest infections, or lung collapse. RESULTS Thirty-three patients (5 tracheal and 28 bronchial diseases) required 55 BES during the study period. The smallest patient weighed 1.8 kg. Median age of patient at first stent implantation was 13.1 months (IQR 4.9-58.3). The majority of the bronchial stents were in the left main bronchus (93%), of which 57% for vascular compression. Repeat stents were used in 19 patients (57.7%), with a range of two to four times. We did not experience erosion, infection, or obstructive granuloma needing removal by forceps or lasering. Three stent grid occluded with secretions needing bronchoscopic lavage. Stent migration occurred in three patients. CONCLUSIONS BES holds promise as a treatment option with low rate of adverse effects for a specific subset of pediatric patients with airway malacia or vascular compression. Further studies are warranted.
Collapse
Affiliation(s)
- Federico Minen
- Paediatric Intensive Care Unit, Evelina London Children's Hospital, London, UK
| | - Andrew Durward
- Paediatric Intensive Care Unit, Sidra Medicine, Doha, Qatar
| | - Paul James
- Paediatric Intensive Care Unit, Evelina London Children's Hospital, London, UK
| | | | - Haran Jogeesvaran
- Paediatric Radiology, Evelina London Children's Hospital, London, UK
| | - Gareth J Morgan
- Paediatric Cardiology, Evelina London Children's Hospital, London, UK
- The Heart Institute, Children's Hospital of Colorado, University of Colorado, Denver, Colorado, USA
| | - Andrew Nyman
- Paediatric Intensive Care Unit, Evelina London Children's Hospital, London, UK
| |
Collapse
|
5
|
Mondal A, Visner GA, Kaza AK, Dupont PE. A novel ex vivo tracheobronchomalacia model for airway stent testing and in vivo model refinement. J Thorac Cardiovasc Surg 2023; 166:679-687.e1. [PMID: 37156367 PMCID: PMC10524727 DOI: 10.1016/j.jtcvs.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 03/14/2023] [Accepted: 04/10/2023] [Indexed: 05/10/2023]
Abstract
OBJECTIVES We sought to develop an ex vivo trachea model capable of producing mild, moderate, and severe tracheobronchomalacia for optimizing airway stent design. We also aimed to determine the amount of cartilage resection required for achieving different tracheobronchomalacia grades that can be used in animal models. METHODS We developed an ex vivo trachea test system that enabled video-based measurement of internal cross-sectional area as intratracheal pressure was cyclically varied for peak negative pressures of 20 to 80 cm H2O. Fresh ovine tracheas were induced with tracheobronchomalacia by single mid-anterior incision (n = 4), mid-anterior circumferential cartilage resection of 25% (n = 4), and 50% per cartilage ring (n = 4) along an approximately 3-cm length. Intact tracheas (n = 4) were used as control. All experimental tracheas were mounted and experimentally evaluated. In addition, helical stents of 2 different pitches (6 mm and 12 mm) and wire diameters (0.52 mm and 0.6 mm) were tested in tracheas with 25% (n = 3) and 50% (n = 3) circumferentially resected cartilage rings. The percentage collapse in tracheal cross-sectional area was calculated from the recorded video contours for each experiment. RESULTS Ex vivo tracheas compromised by single incision and 25% and 50% circumferential cartilage resection produce tracheal collapse corresponding to clinical grades of mild, moderate, and severe tracheobronchomalacia, respectively. A single anterior cartilage incision produces saber-sheath type tracheobronchomalacia, whereas 25% and 50% circumferential cartilage resection produce circumferential tracheobronchomalacia. Stent testing enabled the selection of stent design parameters such that airway collapse associated with moderate and severe tracheobronchomalacia could be reduced to conform to, but not exceed, that of intact tracheas (12-mm pitch, 0.6-mm wire diameter). CONCLUSIONS The ex vivo trachea model is a robust platform that enables systematic study and treatment of different grades and morphologies of airway collapse and tracheobronchomalacia. It is a novel tool for optimization of stent design before advancing to in vivo animal models.
Collapse
Affiliation(s)
- Abhijit Mondal
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Mass; Department of Surgery, Harvard Medical School, Boston, Mass.
| | - Gary A Visner
- Division of Pulmonary Medicine, Boston Children's Hospital, Boston, Mass; Department of Pediatrics, Harvard Medical School, Boston, Mass
| | - Aditya K Kaza
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Mass; Department of Surgery, Harvard Medical School, Boston, Mass
| | - Pierre E Dupont
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Mass; Department of Surgery, Harvard Medical School, Boston, Mass
| |
Collapse
|
6
|
El-Said H, Price K, Hussein A, Ganta S, Rao A, Nigro J, Brigger MT. Bronchial Remodeling Following Airway Stenting in Pediatric Patients With Tracheobronchial and Congenital Heart Disease. JOURNAL OF THE SOCIETY FOR CARDIOVASCULAR ANGIOGRAPHY & INTERVENTIONS 2023; 2:101068. [PMID: 39132388 PMCID: PMC11307877 DOI: 10.1016/j.jscai.2023.101068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 06/11/2023] [Accepted: 06/22/2023] [Indexed: 08/13/2024]
Abstract
Background Treatment of tracheobronchial disease in medically complex infants with congenital heart disease (CHD) is often challenging. When conservative management or surgery fails or is contraindicated, airway stenting can allow for advancement of care or weaning of respiratory support. Methods We identified 8 cases of airway stenting with balloon-expandable coronary bare-metal stents performed at our institution between February 2019 and September 2022 to relieve conservative treatment-refractory tracheobronchial disease in pediatric patients with CHD. All patients underwent rigid microlaryngoscopy, bronchoscopy, and flexible bronchoscopy as well as computed tomography angiography. Results Eight patients underwent technically uncomplicated placement of balloon-expandable coronary bare-metal stents in the trachea or bronchus. Immediate improvement in respiratory parameters was noted following stent placement. Six patients were able to wean mechanical ventilation following stent placement, with a median of 2.5 days of mechanical ventilation following the procedure (range, 0-219). All stents were subsequently endoscopically removed at a median of 6.8 months (range, 0.4-16.3 months). In 6 patients, bronchoscopy after stent removal demonstrated a rounder configuration of the airway consistent with bronchial remodeling. Conclusions In pediatric patients with tracheobronchial and CHD, airway stenting with balloon-expandable bare-metal coronary stents relieved respiratory symptoms with minimal complications and resulted in bronchial remodeling after stent removal.
Collapse
Affiliation(s)
- Howaida El-Said
- Pediatric Cardiology, Rady Children’s Hospital, San Diego, California
| | - Katherine Price
- University of California San Diego School of Medicine, San Diego, California
| | - Amira Hussein
- Pediatric Cardiology, Rady Children’s Hospital, San Diego, California
| | - Srujan Ganta
- Cardiothoracic Surgery, Rady Children’s Hospital, San Diego, California
| | - Aparna Rao
- Pediatric Pulmonology, Rady Children’s Hospital, San Diego, California
| | - John Nigro
- Cardiothoracic Surgery, Rady Children’s Hospital, San Diego, California
| | - Matthew T. Brigger
- Pediatric Otolaryngology, Rady Children’s Hospital, San Diego, California
- Department of Otolaryngology-Head and Neck Surgery, University of California San Diego, San Diego, California
| |
Collapse
|
7
|
A New Removable Helical Metallic Stent for the Treatment of Tracheomalacia in Children: Study in Pathological Animal Model. J Clin Med 2022; 11:jcm11226757. [PMID: 36431234 PMCID: PMC9695607 DOI: 10.3390/jcm11226757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/10/2022] [Accepted: 11/14/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Congenital tracheomalacia is a pathology with no consensus of medical or surgical approach. The permanent nature and the major complications associated with metallic stents have limited their use over the years. The purpose of this study was to evaluate the feasibility of a helical stent design removal. METHODS Ten dogs diagnosed with tracheal collapse and treated with the helical stent were involved in the study. Animals were classified into three groups depending on stent indwelling time. Prior to the removal, endoscopic evaluation was performed to assess endothelization grade, mucous accumulation, and the presence of stenosis. During the removal, bleeding, fracture, or impossibility of removal were noted. After the removal, all macroscopic mucosal changes were recorded. RESULTS Technical success was 100%, without any complications. Complete epithelization of the stent was visualized in 7/10 animals. The removal procedure duration ranged from 2-12 min. At post-removal endoscopy, bleeding or epithelial damage, was visualized in any case. Stent fracture during removal occurred in one animal. CONCLUSIONS The removal of a metallic stent with spiral geometry is feasible, simple, and without complications, regardless of the degree of neo-epithelialization.
Collapse
|
8
|
García-Martínez L, Laín Fernández A, Iglesias-Serrano I, Giné Prades C, Soriano-Arandes A, López M. Endobronchial tuberculosis in children: Defining the role of interventional bronchoscopy. Pediatr Pulmonol 2022; 57:2688-2695. [PMID: 35950618 DOI: 10.1002/ppul.26084] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 06/07/2022] [Accepted: 07/16/2022] [Indexed: 11/11/2022]
Abstract
INTRODUCTION Endobronchial tuberculosis (EBTB) can lead to bronchopulmonary complications when diagnosis is delayed. Bronchoscopic treatment in children can be challenging due to small airway size. We report our experience treating children with EBTB. METHODS Retrospective study (2014-2020) of patients diagnosed with EBTB. Flexible bronchoscopy (FB) was performed in patients with previous diagnosis of pulmonary tuberculosis (PTB), after respiratory/radiological worsening was observed in spite of medical treatment. Treatment consisted in oral corticotherapy in all patients, and interventional bronchoscopy in selected cases. Our aim is to describe the endoscopic findings, interventional bronchoscopy alternatives, and outcome. RESULTS Of 45 patients with PTB, 13 (28.9%, 7 M/6 F) were diagnosed with EBTB, with a mean age of 3.9 years (0.4-12.8). Four bronchoscopic patterns were observed. Endobronchial granuloma (N:9; 69.2%): Excision with rigid bronchoscopy was achieved in five (1-5 procedures per patient), while corticotherapy alone was preferred in the remaining four due to small size/distal location of the granuloma. Caseum obstruction (2; 15.4%): dense mucous molds were removed with flexible/rigid bronchoscopy (6 and 8 procedures, respectively). Bronchial stenosis (1; 7.7%): two balloon dilatations with mitomycin-C application were performed. Extrinsic compression (1; 7.7%): oral corticotherapy alone was initiated. One patient developed bronchoscopy-related complications (pneumothorax requiring thoracic tube 48 h). With a medium follow-up of 4.6 years (1.8-7.6), three patients developed bronchiectasis while the remaining 10 improved clinically and radiologically. CONCLUSION Bronchoscopic findings in EBTB include granuloma, stenosis, caseum obstruction and external compression. In selected cases, interventional bronchoscopy can minimize long-term bronchopulmonary complications.
Collapse
Affiliation(s)
- Laura García-Martínez
- Pediatric Surgery Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Ana Laín Fernández
- Pediatric Surgery Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Ignacio Iglesias-Serrano
- Pediatric Respiratory Medicine Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Carles Giné Prades
- Pediatric Surgery Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Antoni Soriano-Arandes
- Paediatric Infectious Diseases and Immunodeficiencies Departament, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Manuel López
- Pediatric Surgery Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| |
Collapse
|
9
|
Paunović N, Marbach J, Bao Y, Berger V, Klein K, Schleich S, Coulter FB, Kleger N, Studart AR, Franzen D, Luo Z, Leroux J. Digital Light 3D Printed Bioresorbable and NIR-Responsive Devices with Photothermal and Shape-Memory Functions. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2200907. [PMID: 35896948 PMCID: PMC9507367 DOI: 10.1002/advs.202200907] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 06/23/2022] [Indexed: 06/15/2023]
Abstract
Digital light processing (DLP) 3D printing is a promising technique for the rapid manufacturing of customized medical devices with high precision. To be successfully translated to a clinical setting, challenges in the development of suitable photopolymerizable materials have yet to be overcome. Besides biocompatibility, it is often desirable for the printed devices to be biodegradable, elastic, and with a therapeutic function. Here, a multifunctional DLP printed material system based on the composite of gold nanorods and polyester copolymer is reported. The material demonstrates robust near-infrared (NIR) responsiveness, allowing rapid and stable photothermal effect leading to the time-dependent cell death. NIR light-triggerable shape transformation is demonstrated, resulting in a facilitated insertion and expansion of DLP printed stent ex vivo. The proposed strategy opens a promising avenue for the design of multifunctional therapeutic devices based on nanoparticle-polymer composites.
Collapse
Affiliation(s)
- Nevena Paunović
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
| | - Jessica Marbach
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
| | - Yinyin Bao
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
| | - Valentine Berger
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
| | - Karina Klein
- Musculoskeletal Research UnitVetsuisse FacultyUniversity of ZurichZurich8057Switzerland
| | - Sarah Schleich
- Musculoskeletal Research UnitVetsuisse FacultyUniversity of ZurichZurich8057Switzerland
| | | | - Nicole Kleger
- Complex MaterialsDepartment of MaterialsETH ZurichZurich8093Switzerland
| | - André R. Studart
- Complex MaterialsDepartment of MaterialsETH ZurichZurich8093Switzerland
| | - Daniel Franzen
- Department of PulmonologyUniversity Hospital ZurichZurich8006Switzerland
| | - Zhi Luo
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical EngineeringSouthern University of Science and TechnologyShenzhen518055P. R. China
| | - Jean‐Christophe Leroux
- Institute of Pharmaceutical SciencesDepartment of Chemistry and Applied BiosciencesETH ZurichZurich8093Switzerland
| |
Collapse
|
10
|
Zou H, Zhang J, Zhan K, Mou XZ, Zhu B. A narrative review of new research progress regarding the use of airway stents in benign airway stenosis. Expert Rev Respir Med 2022; 16:651-659. [PMID: 35793263 DOI: 10.1080/17476348.2022.2099379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Benign airway stenosis is a severe disease that can result in death with improper treatment. Clinicians must know about airway stents to choose the best one in their daily practice. AREAS COVERED PubMed, Embase, and other electronic databases and websites were searched to identify relevant randomized controlled trials and meta-analyses. This review summarizes different types of airway stents and analyzes their advantages and disadvantages. EXPERT OPINION Increasing attention has been given to the indications and prognosis of benign airway stenosis treated with different airway stents. With more investigations and data, better alternatives to silicone stents could be developed in the future.
Collapse
Affiliation(s)
- Hai Zou
- Department of Critical Care, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jun Zhang
- Department of Pulmonary and Critical Care Medicine, LongHua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Kan Zhan
- College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou, China
| | - Xiao-Zhou Mou
- Key Laboratory of Cancer Molecular Diagnosis and Individualized Therapy of Zhejiang Province, Zhejiang Provincial People's Hospital, Affiliated People's Hospital of Hangzhou Medical College, Hangzhou, China
| | - Biao Zhu
- Department of Critical Care, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| |
Collapse
|
11
|
Morante-Valverde R, Usategui A, López M, Grau M, Luna-Paredes MC, Albi S, Alonso-Riaño M, Pablos JL, Antón-Pacheco JL. Histological and structural effects of biodegradable polydioxanone stents in the rabbit trachea. Eur J Cardiothorac Surg 2022; 62:6628586. [PMID: 35781568 DOI: 10.1093/ejcts/ezac380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 06/03/2022] [Accepted: 06/30/2022] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the potential biologic effects caused by successive placement of biodegradable polydioxanone (PDO) stents in the rabbit trachea. PDO stents could eventually induce a fibroproliferative reaction in the submucosa that could be beneficial in the treatment of malacia due to an increase in its consistency without impairing the tracheal lumen. METHODS Sixteen adult NZ rabbits were distributed into 3 groups with different survival times according to the number of stents placed: One stent (14 weeks), 2 stents (28 w.), and 3 stents (42 w.). Stent insertion was performed endoscopically in the cervical trachea of the animal. Histopathological studies included Masson's trichrome staining for submucosal fibrosis and Safranin O to assess structural integrity of cartilage. Potential inflammatory changes were analysed by means of immunohistochemistry determining the number of CD45 positive cells. RESULTS Stent placement was successful in every case. Histological studies did not show a statistically significant increase in tracheal wall collagen area and cartilage structure was not modified in those rabbits with one or more PDO stents inserted compared to non-stented tracheal sections. Furthermore, no statistically significant changes in the number of CD45+ cells were observed in stented tracheal segments compared to normal tracheal tissues. CONCLUSIONS According to our data, successive PDO stenting caused mild inflammatory changes in the tracheal wall, no increase in the collagen matrix, and the cartilaginous support was not modified during a long follow-up period (up to 42 weeks). These findings suggest that they may be safe and show good biocompatibility in the long-term.
Collapse
Affiliation(s)
- Rocío Morante-Valverde
- Pediatric Surgery Division & Pediatric Airway Unit. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Universidad Complutense de Madrid. Spain
| | - Alicia Usategui
- Inflammatory and Autoimmune Diseases Research Group. Instituto de Investigación Hospital U. 12 de Octubre (imas12). Avda. de Córdoba s/n, Madrid 28041. Spain
| | - María López
- Pediatric Surgery Division & Pediatric Airway Unit. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Universidad Complutense de Madrid. Spain
| | - Montserrat Grau
- Research Center, Veterinary Unit. Instituto de Investigación Hospital U. 12 de Octubre (imas12). Avda. de Córdoba s/n, Madrid 28041. Spain
| | - Ma Carmen Luna-Paredes
- Pulmonary Unit, Division of Pediatrics. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Spain
| | - Salomé Albi
- Pulmonary Unit, Division of Pediatrics. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Spain
| | - Marina Alonso-Riaño
- Division of Pathology. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Spain
| | - José L Pablos
- Inflammatory and Autoimmune Diseases Research Group. Instituto de Investigación Hospital U. 12 de Octubre (imas12). Avda. de Córdoba s/n, Madrid 28041. Spain
| | - Juan L Antón-Pacheco
- Pediatric Surgery Division & Pediatric Airway Unit. Hospital Universitario 12 de Octubre. Avda. de Córdoba s/n, Madrid 28041. Universidad Complutense de Madrid. Spain.,Inflammatory and Autoimmune Diseases Research Group. Instituto de Investigación Hospital U . 12 de Octubre (imas12). Avda. de Córdoba s/n, Madrid, 28041, . Spain
| |
Collapse
|
12
|
Choi JS, Seok J, Eom MR, Jung E, Park SA, Joo SM, Jun YJ, Son KW, Kwon SK. Endoscopically Applied Biodegradable Stent in a Rabbit Model of Pediatric Tracheomalacia. Clin Exp Otorhinolaryngol 2021; 14:328-337. [PMID: 33081438 PMCID: PMC8373836 DOI: 10.21053/ceo.2020.01627] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 09/26/2020] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVES A polydioxanone (PDO) stent was developed to treat tracheomalacia in pediatric patients. However, its safety and efficacy need to be verified in animal studies before clinical trials in patients can be conducted. This study evaluated the safety and efficacy of a PDO stent in normal and tracheomalacia-model rabbits. METHODS In total, 29 New Zealand white rabbits were used: 13 for evaluating the biocompatibility of the PDO stent in normal rabbits and 16 for the creation of a tracheomalacia model. The tracheomalacia model was successfully established in 12 rabbits, and PDO stents were placed in eight of those rabbits. RESULTS The PDO stent was successfully positioned in the trachea of the normal rabbits using an endoscopic approach, and its degradation was observed 10 weeks later. The stent fragments did not induce distal airway obstruction or damage, and the mucosal changes that occurred after stent placement were reversed after degradation. The same procedure was performed on the tracheomalacia-model rabbits. The survival duration of the tracheomalacia rabbits with and without stents was 49.0±6.8 and 1.0±0.8 days, respectively. Thus, the PDO stent yielded a significant survival gain (P=0.001). In the tracheomalacia rabbits, stent degradation and granulation tissue were observed 7 weeks after placement, leading to airway collapse and death. CONCLUSION We successfully developed a PDO stent and an endoscopic guide placement system. The degradation time of the stent was around 10 weeks in normal rabbits, and its degradation was accelerated in the tracheomalacia model. The mucosal changes associated with PDO stent placement were reversible. Placement of the PDO stent prolonged survival in tracheomalacia-model rabbits.
Collapse
Affiliation(s)
- Ji Suk Choi
- Department of Otorhinolaryngology-Head and Neck Surgery, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Jungirl Seok
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Seoul, Korea
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Korea
| | - Min Rye Eom
- Department of Otorhinolaryngology-Head and Neck Surgery, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Eungee Jung
- Department of Otorhinolaryngology-Head and Neck Surgery, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Su A Park
- Department of Nature-Inspired Nanoconvergence Systems, Korea Institute of Machinery and Materials, Daejeon, Korea
| | | | | | | | - Seong Keun Kwon
- Department of Otorhinolaryngology-Head and Neck Surgery, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Seoul, Korea
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
13
|
Bronchial stenting in infants with severe bronchomalacia: Technique and outcomes. Int J Pediatr Otorhinolaryngol 2021; 145:110703. [PMID: 33910043 DOI: 10.1016/j.ijporl.2021.110703] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Revised: 03/24/2021] [Accepted: 04/01/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To report the first use of a balloon expandable bare metal stent for treating infant bronchomalacia. BACKGROUND Infant bronchomalacia often requires prolonged mechanical ventilation and can be life-threatening. Effective treatment for severe infant bronchomalacia continues to be elusive. We present three cases of bronchial stenting for no-option or treatment refractory infant bronchomalacia. METHODS Three consecutive cases of stenting to relieve conservative treatment refractory severe infant bronchomalacia were performed between February 2019 and December 2020. Initial diagnosis was confirmed with Computed Tomography (CT) angiography. Patients underwent rigid micro laryngoscopy, bronchoscopy, and flexible bronchoscopy to evaluate the airway. Initial conservative management strategies were pursued. Patients failing initial conservative management strategies were considered for rescue bronchial stenting. RESULTS Our initial clinical experience with a coronary bare metal stent for these procedures has been favorable. The stent was easy to deploy with precision. We did not encounter stent embolization or migration. There was sufficient stent radial strength to relieve bronchomalacia without causing restenosis or erosion. There was no significant granulation tissue formation. In one patient, the stent was removed after 12 months of somatic growth; this was uneventful and bronchial patency was maintained. There were no complications in any of our patients regarding stent placement and reliability. CONCLUSION In cases of three infants with severe bronchomalacia, we found that bronchial stenting with the bare metal coronary stent was effective in relieving bronchial stenosis.
Collapse
|
14
|
Bellia-Munzon G, Cieri P, Toselli L, Cuestas G, Doormann F, Gabaldón-Massé P, Rodriguez V, Bellia-Munzon P. Resorbable airway splint, stents, and 3D reconstruction and printing of the airway in tracheobronchomalacia. Semin Pediatr Surg 2021; 30:151063. [PMID: 34172216 DOI: 10.1016/j.sempedsurg.2021.151063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Tracheobronchomalacia (TBM) is the most common tracheobronchial obstruction. Most cases are mild to moderate; therefore, they do not need surgical treatment. Severe tracheomalacia, however, represents a diagnostic and therapeutic challenge since they are very heterogeneous. In the armamentarium of resources for the treatment of dynamic airway collapse, splints and stents are two underused strategies and yet, they may represent the best alternative in selected cases. Lately, computed tomography 3D reconstruction of the airway has been used for the design of virtual models that can be 3D-printed for the creation of novel devices to address training, simulation, and biotechnological implants for refractory and severe airway malformations. This manuscript examines the role of resorbable stents, splints, and the 3D reconstruction and printing of the pediatric airway in tracheobronchomalacia.
Collapse
Affiliation(s)
- Gaston Bellia-Munzon
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Patricio Cieri
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina..
| | - Luzia Toselli
- Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Giselle Cuestas
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Flavia Doormann
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Paula Gabaldón-Massé
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Verónica Rodriguez
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| | - Patricio Bellia-Munzon
- Hospital General de Niños Pedro de Elizalde, Buenos Aires, Argentina.; Fundación Hospitalaria Mother and Child Medical Center, Buenos Aires, Argentina
| |
Collapse
|
15
|
Abstract
Congenital airway anomalies (CAA) include a variety of conditions that cause respiratory distress in neonates and infants. These malformations occur at various anatomic levels and manifest in a wide spectrum of airway symptoms, with presentation significantly influenced by the level at which obstruction occurs as well as by the severity of obstruction. The prevalence of congenital airway malformations has been estimated to range between 0.2 and 1 in 10,000 live births. The most frequent CAA are laryngomalacia, bilateral vocal cord paralysis, subglottic stenosis, laryngeal webs, subglottic hemangioma, tracheomalacia, congenital tracheal stenosis, laryngotracheal cleft, and tracheal agenesis.
Collapse
Affiliation(s)
- Patricio Varela
- Program Director Pediatric Airway Unit, Mackenna Children's Hospital, University of Chile, Clínica Las Condes Medical Center. Santiago, Chile.
| | - Claudia Schweiger
- Pediatric ENT, Hospital De Clinicas de Porto Alegre, Porto Alegre, Brazil
| |
Collapse
|
16
|
Goussard P, Pohunek P, Eber E, Midulla F, Di Mattia G, Merven M, Janson JT. Pediatric bronchoscopy: recent advances and clinical challenges. Expert Rev Respir Med 2021; 15:453-475. [PMID: 33512252 DOI: 10.1080/17476348.2021.1882854] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Introduction: During the last 40 years equipment has been improved with smaller instruments and sufficient size working channels. This has ensured that bronchoscopy offers therapeutic and interventional options.Areas covered: We provide a review of recent advances and clinical challenges in pediatric bronchoscopy. This includes single-use bronchoscopes, endobronchial ultrasound, and cryoprobe. Bronchoscopy in persistent preschool wheezing and asthma is included. The indications for interventional bronchoscopy have amplified and included balloon dilatation, endoscopic intubation, the use of airway stents, whole lung lavage, closing of fistulas and air leak, as well as an update on removal of foreign bodies. Others include the use of laser and microdebrider in airway surgery. Experience with bronchoscope during the COVID-19 pandemic has been included in this review. PubMed was searched for articles on pediatric bronchoscopy, including rigid bronchoscopy as well as interventional bronchoscopy with a focus on reviewing literature in the past 5 years.Expert opinion: As the proficiency of pediatric interventional pulmonologists continues to grow more interventions are being performed. There is a scarcity of published evidence in this field. Courses for pediatric interventional bronchoscopy need to be developed. The COVID-19 experience resulted in safer bronchoscopy practice for all involved.
Collapse
Affiliation(s)
- P Goussard
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa
| | - P Pohunek
- Division of Pediatric Respiratory Diseases, Pediatric Department, 2nd Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
| | - E Eber
- Department of Paediatrics and Adolescent Medicine, Head, Division of Paediatric Pulmonology and Allergology, Medical University of Graz, Graz, Austria
| | - F Midulla
- Department of Maternal Infantile and Urological Sciences, "Sapienza" University of Rome, Rome, Italy
| | - G Di Mattia
- Department of Maternal Infantile and Urological Sciences, "Sapienza" University of Rome, Rome, Italy
| | - M Merven
- Department Otorhinolaryngology, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa
| | - J T Janson
- Department of Surgical Sciences, Division of Cardio-Thoracic Surgery, Stellenbosch University, and Tygerberg Hospital, Tygerberg, South Africa
| |
Collapse
|
17
|
Wu J, Mady LJ, Roy A, Aral AM, Lee B, Zheng F, Catalin T, Chun Y, Wagner WR, Yang K, Trejo Bittar HE, Chi D, Kumta PN. In-vivo efficacy of biodegradable ultrahigh ductility Mg-Li-Zn alloy tracheal stents for pediatric airway obstruction. Commun Biol 2020; 3:787. [PMID: 33339963 PMCID: PMC7749127 DOI: 10.1038/s42003-020-01400-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 10/09/2020] [Indexed: 11/24/2022] Open
Abstract
Pediatric laryngotracheal stenosis is a complex congenital or acquired airway injury that may manifest into a potentially life-threatening airway emergency condition. Depending on the severity of obstruction, treatment often requires a combination of endoscopic techniques, open surgical repair, intraluminal stenting, or tracheostomy. A balloon expandable biodegradable airway stent maintaining patency while safely degrading over time may address the complications and morbidity issues of existing treatments providing a less invasive and more effective management technique. Previous studies have focused on implementation of degradable polymeric scaffolds associated with potentially life-threatening pitfalls. The feasibility of an ultra-high ductility magnesium-alloy based biodegradable airway stents was demonstrated for the first time. The stents were highly corrosion resistant under in vitro flow environments, while safely degrading in vivo without affecting growth of the rabbit airway. The metallic matrix and degradation products were well tolerated by the airway tissue without exhibiting any noticeable local or systemic toxicity.
Collapse
Affiliation(s)
- Jingyao Wu
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Leila J Mady
- Department of Otolaryngology, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Abhijit Roy
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Ali Mübin Aral
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Boeun Lee
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Feng Zheng
- Institute of Metal Research, Chinese Academic of Sciences, Shenyang, 110016, China
| | - Toma Catalin
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, 15261, USA
- McGowan Institute of Regenerative Medicine, Pittsburgh, PA, 15261, USA
| | - Youngjae Chun
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- McGowan Institute of Regenerative Medicine, Pittsburgh, PA, 15261, USA
- Department of Industrial Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - William R Wagner
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- McGowan Institute of Regenerative Medicine, Pittsburgh, PA, 15261, USA
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Ke Yang
- Institute of Metal Research, Chinese Academic of Sciences, Shenyang, 110016, China
| | - Humberto E Trejo Bittar
- Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, PA, 15213, USA
| | - David Chi
- Department of Otolaryngology, Children's Hospital of Pittsburgh of UPMC, Pittsburgh, PA, 15224, USA
| | - Prashant N Kumta
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA.
- McGowan Institute of Regenerative Medicine, Pittsburgh, PA, 15261, USA.
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA.
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, 15261, USA.
- Department of Oral Biology, School of Dental Medicine, University of Pittsburgh, Pittsburgh, PA, 15261, USA.
- Center for Complex Engineering Multi-functional Materials, University of Pittsburgh, Pittsburgh, PA, 15261, USA.
| |
Collapse
|
18
|
Stramiello JA, Mohammadzadeh A, Ryan J, Brigger MT. The role of bioresorbable intraluminal airway stents in pediatric tracheobronchial obstruction: A systematic review. Int J Pediatr Otorhinolaryngol 2020; 139:110405. [PMID: 33017664 DOI: 10.1016/j.ijporl.2020.110405] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 08/24/2020] [Accepted: 09/23/2020] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Tracheal stenosis and tracheobronchomalacia are complicated, patient-specific diseases that can be treated with intraluminal stenting. Most commonly, silicone and metal stents are utilized, however, they pose significant early and late morbidity and are further complicated by growth of the airway in the pediatric population. Given recent improvements in materials science, there is a growing body of evidence suggesting a strong role for bioresorbable intraluminal stents in treating pediatric tracheobronchial obstruction. METHODS A PubMed.gov literature search was performed on December 3, 2019 and May 15, 2020, and a 2-researcher systematic review was performed following the PRISMA criteria. The following search query was utilized: (((((((bioresorbable) OR bioabsorbable) OR resorbable) OR absorbable) OR biodegradable AND airway) OR trachea) AND stent. A pooled statistical analysis was performed on all reported pediatric patients using SPSS software. RESULTS 1369 publications were screened and 26 articles with original data were identified. Materials used included polydioxanone (PDO), poly-l-lactic acid (PLLA), polyglycolic acid/poly-l-lactide co-polymer with Proglactin 910 (Vicryl®-PDS®), polycaprolactone (PCL), magnesium alloys, and co-polymers in varying proportions. Twelve articles presented data on human subjects, 8 of which were case series and case reports on pediatric populations using polydioxanone (PDO) stents. Pooled statistical analysis demonstrated an average age of 19 months (range 0.25-144), 56.5% associated with a cardiovascular anomaly, and overall complication rate of 21.7%, with a stent fragment foreign body being the most common (8.7%), followed by significant granulation tissue (4.3%), stent migration (4.3%), and local stenosis (4.3%). Comparative analysis demonstrated short-term improvement (up to 1 month) has a statistically significant association with tracheobronchomalacia versus tracheal stenosis on chi-squared test (p = 0.001). The remaining analyses did not yield statistical significance. CONCLUSION The reported application of bioresorbable materials as intraluminal airway stents is positive. All comparative animal studies report biocompatibility and fewer morbidities compared to metal and silicone stents, however, in human studies there are concerns over the short interval of degradation and the potential for obstructive foreign bodies in poorly seated stents. Overall, there are clear, reproducible advantages to bioresorbable intraluminal stents in pediatric airway obstruction, as well as common pitfalls, that warrant further research.
Collapse
Affiliation(s)
- Joshua A Stramiello
- Division of Otolaryngology-Head & Neck Surgery, Department of Surgery, University of California San Diego, 200 W Arbor Dr. MC8895, San Diego, CA, 92103, USA
| | - Amir Mohammadzadeh
- UC San Diego School of Medicine, University of California San Diego, 9500 Gilman Dr., La Jolla, CA, 92093, USA
| | - Justin Ryan
- 3D Innovations Lab, Rady Children's Hospital, San Diego, CA, 3020 Children's Way MC5166, San Diego, CA, 92123, USA
| | - Matthew T Brigger
- Division of Otolaryngology-Head & Neck Surgery, Department of Surgery, University of California San Diego, 200 W Arbor Dr. MC8895, San Diego, CA, 92103, USA; Division of Pediatric Otolaryngology, Department of Surgery, Rady Children's Hospital, San Diego, CA, 3020 Children's Way, San Diego, CA, 92123, USA.
| |
Collapse
|
19
|
Rodriguez-Zapater S, Serrano-Casorran C, Guirola JA, Lopez-Minguez S, Bonastre C, de Gregorio MA. Reactivity study of a biodegradable polydioxanone tracheal stent in a rabbit model. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/j.arbr.2020.08.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
20
|
Serrano-Casorran C, Lopez-Minguez S, Rodriguez-Zapater S, Bonastre C, Guirola JA, De Gregorio MA. A new airway spiral stent designed to maintain airway architecture with an atraumatic removal after full epithelization-Research of feasibility and viability in canine patients with tracheomalacia. Pediatr Pulmonol 2020; 55:1757-1764. [PMID: 32407602 DOI: 10.1002/ppul.24816] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 04/30/2020] [Accepted: 05/02/2020] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Surgical management of tracheomalacia is a challenge, with current treatments still presenting numerous complications. In the field of veterinary medicine, this same pathology is present in a significant number of dogs. For this reason, we present an experimental clinical trial performed on canines with tracheobronchomalacia, using a new atraumatic removable tracheal spiral stent (SS). Both implantation procedure and clinical improvement have been analyzed in this study. METHODS In this study, four small dogs, a mean weight of 4.89 kg and body condition scores IV-V, were included. SS was implanted by two different surgical approaches. Image and clinical follow-up have been performed during 90 days. Symptoms were evaluated from 1 to 10 every week. RESULTS This study achieved 100% technical and clinical success. Median tracheal diameters were as follows: cervical 10.85 (3.3), inlet 7.75 (2.1), and carina 7.75 (1.9) mm, and length was 77.5 (26) mm. A 12 × 10 × 100-mm SS was implanted in all cases. Goose honk cough punctuation improved from 8 to 1; also, there were important changes in exercise intolerance, a mean weight loss of 8.76%. The values of modified Karnofsky scale varied from 50 (20) before surgery to 90 (10) after 30 days of surgery. Neither granuloma tissue nor fractures of the prosthesis was observed. CONCLUSION The results in dogs are promising, and a new therapeutic alternative seems to be available for veterinarian field. The similarity of this disease between dogs and newborns suggests that this SS design can also be useful for human trials.
Collapse
Affiliation(s)
- Carolina Serrano-Casorran
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Department of Animal Pathology, University of Zaragoza, Zaragoza, Spain.,Minimally Invasive Unit, Veterinary School of the University of Zaragoza, Spain
| | - Sandra Lopez-Minguez
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Minimally Invasive Unit, Veterinary School of the University of Zaragoza, Spain
| | - Sergio Rodriguez-Zapater
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Minimally Invasive Unit, Veterinary School of the University of Zaragoza, Spain
| | - Cristina Bonastre
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Department of Animal Pathology, University of Zaragoza, Zaragoza, Spain.,Minimally Invasive Unit, Veterinary School of the University of Zaragoza, Spain
| | - Jose A Guirola
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Interventional Radiology Department, Lozano Blesa University Hospital, Zaragoza, Spain
| | - Miguel A De Gregorio
- Minimally Invasive Techniques Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.,Interventional Radiology Department, Lozano Blesa University Hospital, Zaragoza, Spain
| |
Collapse
|
21
|
Rodriguez-Zapater S, Serrano-Casorran C, Guirola JA, Lopez-Minguez S, Bonastre C, de Gregorio MA. Reactivity Study of a Biodegradable Polydioxanone Tracheal Stent in a Rabbit Model. Arch Bronconeumol 2020; 56:643-650. [PMID: 32229053 DOI: 10.1016/j.arbres.2020.02.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 02/14/2020] [Accepted: 02/17/2020] [Indexed: 11/18/2022]
Abstract
INTRODUCTION The objective of this study was to evaluate tracheal reactivity induced by a biodegradable polydioxanone tracheal stent. MATERIALS AND METHODS Twenty-two rabbits were divided into 3 groups assigned to different survival times (30, 60 and 90days post-implantation). A biodegradable stent was implanted in each animal, except for 1 of each group (negative control). Implantation was performed through a small tracheotomy under fluoroscopic control. CT and histopathological studies were scheduled at the end of survival times. RESULTS No animal died during the procedure or follow-up. The stent had disappeared in 100% of the cases at 90days, in 50% at 60days, and in none at 30days. CT studies revealed a greater tracheal wall thickness at 30days than at 60 and 90days (1.60±0.41mm in the central part of the stent versus 1.11±0.18 and 0.94±0.11; P=.007, respectively). No granulomas were observed on histopathology. Some degree of histological changes were noted at 30days, which had reduced at 60 and 90days. Differences were also found in both CT and histology between animals in which the stent was present and animals in which it had degraded. CONCLUSIONS Polydioxanone stents produce a mild reaction that reverts with tracheal degradation. The use of these biodegradable stents in benign tracheal disease is promising.
Collapse
Affiliation(s)
- Sergio Rodriguez-Zapater
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España
| | - Carolina Serrano-Casorran
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España; Departamento de Patología Animal, Universidad de Zaragoza, Zaragoza, España.
| | - José A Guirola
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España; Unidad de Radiología Intervencionista, Hospital Clínico Universitario Lozano Blesa, Zaragoza, España
| | - Sandra Lopez-Minguez
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España
| | - Cristina Bonastre
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España; Departamento de Patología Animal, Universidad de Zaragoza, Zaragoza, España
| | - Miguel A de Gregorio
- GITMI, Grupo de Investigación en Técnicas de Mínima Invasión, Universidad de Zaragoza. DGA Gobierno de Aragón, Zaragoza, España; Unidad de Radiología Intervencionista, Hospital Clínico Universitario Lozano Blesa, Zaragoza, España
| |
Collapse
|
22
|
Zhao F, Xu H, Xue W, Li Y, Sun J, Wang F, Jiang G, Li L, Wang L. Iodinated poly( p-dioxanone) as a facile platform for X-ray imaging of resorbable implantable medical devices. J Biomater Appl 2020; 35:39-48. [PMID: 32192387 DOI: 10.1177/0885328220912842] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Currently, implantable fibrous medical devices still suffer from invisibility under current clinical imaging techniques. To address this problem, 2, 3, 5-triiodobenzoic acid (TIBA) was recruited as a contrast agent, and then a set of iodinated poly(p-dioxanone) (PPDO) fibers was fabricated via melt-spinning hybrid blends of PPDO with TIBA (PPDO/TIBA). The impact of TIBA content on the rheological behavior of blends was evaluated firstly. The physical, chemical, and thermal properties of PPDO/TIBA fibers were investigated accordingly by SEM, FTIR, DSC, and TGA. Moreover, the radiopaque property of PPDO/TIBA hybrid fibers as a potential radio-opacifying platform for medical devices was verified in vitro and in vivo. Finally, the accumulated release results of the hybrid fibers during in vitro degradation indicate the continual X-ray visibility of the hybrid fibers maintains for 22 days. This intriguing iodinated platform may pave the way for constructing fibrous materials with in-situ X-ray tracking property.
Collapse
Affiliation(s)
- Fan Zhao
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| | - Haiyan Xu
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| | - Wen Xue
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| | - Yan Li
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| | - Jing Sun
- Department of Pediatric Cardiology of Xin Hua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Fujun Wang
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| | - Guansen Jiang
- Hangzhou Rejoin Mastin Medical Device Co., Ltd, Hangzhou, China
| | - Lingchen Li
- Hangzhou Rejoin Mastin Medical Device Co., Ltd, Hangzhou, China
| | - Lu Wang
- College of Textiles, Donghua University, Shanghai, China.,Key laboratory of Textile Science and Technology, Ministry of Education, Donghua University, Songjiang, Shanghai, China
| |
Collapse
|
23
|
Mondal A, Ha J, Jo VY, Wu FY, Kaza AK, Dupont PE. Preclinical evaluation of a pediatric airway stent for tracheobronchomalacia. J Thorac Cardiovasc Surg 2020; 161:S0022-5223(20)30572-9. [PMID: 32331821 PMCID: PMC7492470 DOI: 10.1016/j.jtcvs.2020.03.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 03/02/2020] [Accepted: 03/03/2020] [Indexed: 12/30/2022]
Abstract
OBJECTIVES We sought to demonstrate in an animal model that helical stents made from a nickel titanium alloy called nitinol (NiTi) and designed for malacic airways could be delivered and removed without significant trauma while minimally impeding mucus clearance during the period of implantation. METHODS Stents were delivered and removed from the tracheas of healthy 20 kg swine (n = 5) using tools designed to minimize trauma. In 4-week experiments, the stents were implanted on day 0, removed after 3 weeks, and swine were put to death after 4 weeks. Weekly bronchoscopies, radiographs, and mucus clearance examinations were performed in vivo. Hematoxylin and eosin staining and scanning electron microscopy imaging were used to evaluate foreign body response, tracheal tissue reaction, and damage and to measure unciliated regions. RESULTS In all in vivo experiments, the stent was implanted and removed atraumatically. Mucus clearance was maintained throughout the experiment period. Hematoxylin and eosin-stained slides showed that foreign body response and tracheal tissue damage were localized to the stented subsections. Tracheal tissue reaction and damage was further restricted to the epithelium and submucosal layers. Scanning electron microscopy imaging revealed that the cilia were absent only over the contact area between the trachea and the wire forming the helical stent. CONCLUSIONS Helical nitinol stents designed to provide radial support for malacic airways were well tolerated in a porcine model, providing for mucus clearance while also enabling atraumatic removal.
Collapse
Affiliation(s)
- Abhijit Mondal
- Department of Cardiovascular Surgery, Boston Children's Hospital, Boston, Mass.
| | - Junhyoung Ha
- Center of Medical Robotics, Korea Institute of Science and Technology, Seoul, South Korea
| | - Vickie Y Jo
- Department of Pathology, Brigham and Women's Hospital, Boston, Mass
| | - Fei-Yi Wu
- Department of Surgery, Taipei Veteran General Hospital, Taipei City, Taiwan, Republic of China
| | - Aditya K Kaza
- Department of Cardiovascular Surgery, Boston Children's Hospital, Boston, Mass
| | - Pierre E Dupont
- Department of Cardiovascular Surgery, Boston Children's Hospital, Boston, Mass
| |
Collapse
|
24
|
Wang M, Zhu B, Xu X. Follow-Up Investigation of 41 Children After Metallic Airway Stent Implantation: An 8-Year Experience. Front Pediatr 2020; 8:579209. [PMID: 33194910 PMCID: PMC7649206 DOI: 10.3389/fped.2020.579209] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 09/28/2020] [Indexed: 11/24/2022] Open
Abstract
Objective: To present 8-year follow-up outcomes, treatment of complications, and prognosis in children with congenital tracheal stenosis after metallic airway stent implantation. Methods: Retrospective analysis was performed on the clinical records of children who had airway stents placed between May 20, 2011 and May 31, 2016, and on their follow-up records collected on November 31, 2019. Results: During the 8 years follow-up, 41 children underwent airway stenting under flexible bronchoscopy and participated in the follow-up investigation. There were 26 cases with left main bronchus (LMB) stenosis (63.4%), 16 cases with congenital tracheal stenosis (CTS, 39.0%), 12 cases with right main bronchus (RMB) stenosis (29.3%), and 1 case of subglottic stenosis (2.4%). A total of 76 stents were implanted, and 21 patients died after implantation. There were 34 children (82.9%) with congenital heart disease (CHD), while other diseases accounted for <5%. Among children with CHD and those with other conditions, the number of death cases was 19 and 2, respectively; no significant differences were observed between the two groups (P>0.05). The most frequent complications were increased airway secretion (75.8%), stent deformation (66.7%), and granulation tissue hyperplasia (60.6%). The airway stenosis (45.5%) and stent migration (12.1%) occurred at a moderate rate. The less common complications were airway softening (6.1%), and stent breakage (6.1%). Conclusions: The placement and removal of the metallic stent are convenient and quick procedures that can relieve the symptoms of dyspnea caused by airway stenosis in the case of an emergency. After stent implantation, the primary disease should be actively treated, and the stent should be removed as soon as possible after the cause of airway stenosis is successfully removed. Larger stents are more likely to cause complications; thus, a good follow-up system should be established to timely address all the complications.
Collapse
Affiliation(s)
- Meng Wang
- Bayi Children's Hospital, Affiliated to the 7th Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Bin Zhu
- Bayi Children's Hospital, Affiliated to the 7th Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Xuan Xu
- Bayi Children's Hospital, Affiliated to the 7th Medical Center of Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
25
|
Ha J, Mondal A, Zhao Z, Kaza AK, Dupont PE. Pediatric Airway Stent Designed to Facilitate Mucus Transport and Atraumatic Removal. IEEE Trans Biomed Eng 2019; 67:177-184. [PMID: 30990171 PMCID: PMC6947666 DOI: 10.1109/tbme.2019.2910551] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE The goal was to develop a pediatric airway stent for treating tracheobronchomalacia that could be used as an alternative to positive pressure ventilation. The design goals were for the stent to allow mucus flow and to resist migration inside the airways, while also enabling easy insertion and removal. METHODS A helical stent design, together with insertion and removal tools, is presented. A mechanics model of stent compression is derived to assist in selecting stent design parameters (pitch and wire diameter) that provide the desired amount of tracheal support, while introducing the minimal amount of foreign material into the airway. Worst-case airway area reduction with stent support is investigated experimentally using a pressurized tracheal phantom matched to porcine tracheal tissue properties. The stent design is then evaluated in a porcine in vivo experiment. RESULTS Phantom testing validated the mechanics model of stent compression. In vivo testing demonstrated that the stent was well tolerated by the animal. Since the helical design covers only a small portion of the epithelium, mucus transport through the stented region was minimally impeded. Furthermore, the screw-like stent resisted migration, while also providing for atraumatic removal through the use of an unscrewing motion during removal. CONCLUSION The proposed stent design and tools represent a promising approach to prevent airway collapse in children with tracheobronchomalacia. SIGNIFICANCE The proposed technology overcomes the limitations of existing airway stents and may provide an alternative to maintaining children on a ventilator.
Collapse
|
26
|
Abstract
Congenital malformations of the trachea include a variety of conditions that cause respiratory distress in neonates and infants. A number of anomalies are self-limiting while others are life-threatening and require immediate therapy. The prevalence of congenital airway malformations has been estimated to range between 0.2 and 1 in 10,000 live births. The most frequent congenital tracheal malformations are: tracheomalacia, congenital tracheal stenosis, laryngotracheal cleft and tracheal agenesis. The management of congenital tracheal malformations is complex and requires an individualized approach delivered by a multidiscipilinary team within centralized units with the necessary expertise.
Collapse
Affiliation(s)
- Patricio Varela
- Program Director Pediatric Airway Unit, Mackenna Children's Hospital, Clínica Las Condes Medical Center, University of Chile, Santiago, Chile.
| | - Michelle Torre
- Director Pediatric Airway Unit, Gaslinni Institute, Genoa, Italy
| | - Claudia Schweiger
- Pediatric Otolaryngology and Head and Neck Surgeon, Hospital de Clínicas de Porto Alegre, Porto Alegre, Brazil
| | - Hiroki Nakamura
- National Children's Research Centre, Our Lady's Children's Hospital, Dublin, Ireland
| |
Collapse
|
27
|
Donato L, Mai Hong Tran T, Ghori UK, Musani AI. Pediatric Interventional Pulmonology. Clin Chest Med 2018; 39:229-238. [DOI: 10.1016/j.ccm.2017.11.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
28
|
Eber E, Antón-Pacheco JL, de Blic J, Doull I, Faro A, Nenna R, Nicolai T, Pohunek P, Priftis KN, Serio P, Coleman C, Masefield S, Tonia T, Midulla F. ERS statement: interventional bronchoscopy in children. Eur Respir J 2017; 50:50/6/1700901. [DOI: 10.1183/13993003.00901-2017] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Accepted: 08/08/2017] [Indexed: 12/25/2022]
Abstract
Paediatric airway endoscopy is accepted as a diagnostic and therapeutic procedure, with an expanding number of indications and applications in children. The aim of this European Respiratory Society task force was to produce a statement on interventional bronchoscopy in children, describing the evidence available at present and current clinical practice, and identifying areas deserving further investigation. The multidisciplinary task force panel performed a systematic review of the literature, focusing on whole lung lavage, transbronchial and endobronchial biopsy, transbronchial needle aspiration with endobronchial ultrasound, foreign body extraction, balloon dilation and occlusion, laser-assisted procedures, usage of airway stents, microdebriders, cryotherapy, endoscopic intubation, application of drugs and other liquids, and caregiver perspectives. There is a scarcity of published evidence in this field, and in many cases the task force had to resort to the collective clinical experience of the committee to develop this statement. The highlighted gaps in knowledge underline the need for further research and serve as a call to paediatric bronchoscopists to work together in multicentre collaborations, for the benefit of children with airway disorders.
Collapse
|
29
|
Sandu K, Reinhard A, Lambercy K, Pretre R, Gorostidi F. Temporary tracheal stenting using endovascular prosthesis in the management of severe refractory stenosis following slide tracheoplasty. Eur Arch Otorhinolaryngol 2017; 275:275-280. [PMID: 29075983 DOI: 10.1007/s00405-017-4792-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 10/24/2017] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate the role of endovascular stents in temporary tracheal stenting and endoscopic treatment strategy for patients with severe refractory tracheal stenosis following slide tracheoplasty. METHODS Two patients had severe tracheal stenosis after slide tracheoplasty for long segment congenital tracheal stenosis. Both these patients were managed endoscopically and an endovascular prosthesis was used to temporarily stent the trachea. Short and long term results were evaluated clinically and with repeated endoscopies. RESULTS The 2 patients had an excellent recovery immediately after the stent placement and continue to have an optimal, age-appropriate stable tracheal diameter after stent removal. CONCLUSION Endovascular stents can be temporarily used to stent the trachea in the endoscopic treatment strategy to correct refractory severe tracheal stenosis following slide tracheoplasty.
Collapse
Affiliation(s)
- Kishore Sandu
- Department of Otorhinolaryngology, Lausanne University Hospital, 1005, Lausanne, Switzerland.
| | - Antoine Reinhard
- Department of Otorhinolaryngology, Lausanne University Hospital, 1005, Lausanne, Switzerland
| | - Karma Lambercy
- Department of Otorhinolaryngology, Lausanne University Hospital, 1005, Lausanne, Switzerland
| | - Rene Pretre
- Department of Cardiac Surgery, Lausanne University Hospital, 1005, Lausanne, Switzerland
| | - Francois Gorostidi
- Department of Otorhinolaryngology, Lausanne University Hospital, 1005, Lausanne, Switzerland
| |
Collapse
|
30
|
Lueck S, Mohr M, Werner C, Schmidt C, Malec E, Januszewska K. Temporary Tracheal Stenting After Pulmonary Artery Sling Repair in a Newborn. World J Pediatr Congenit Heart Surg 2017; 11:NP69-NP71. [PMID: 28933231 DOI: 10.1177/2150135117713740] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Pulmonary artery sling (PAS) is a rare disease frequently associated with severe malacia and stenosis of the trachea. We present a two-day-old newborn that underwent urgent surgery for PAS and needed prolonged respiratory support afterward. Temporary airway stenting above the level of the tracheal bifurcation was performed five days after surgery to overcome severe airway obstruction caused by tracheomalacia and laceration of the tracheal mucosa after diagnostic bronchoscopy. Two days after the procedure, the child could be extubated and after two weeks the stent was removed without complications. Temporary tracheal stenting after PAS repair can be an effective therapeutic strategy in newborns with tracheal obstruction and allows timely weaning from ventilator support.
Collapse
Affiliation(s)
- Sabrina Lueck
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, University Hospital Muenster, Muenster, Germany
| | - Michael Mohr
- Department of Medicine A-Hematology, Oncology and Pneumology, University Hospital Muenster, Muenster, Germany
| | - Claudius Werner
- Department of General Pediatrics, University Children's Hospital Muenster, Muenster, Germany
| | - Christoph Schmidt
- Department of Anesthesiology, Intensive Care and Pain Medicine, University Hospital Muenster, Muenster, Germany
| | - Edward Malec
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, University Hospital Muenster, Muenster, Germany
| | - Katarzyna Januszewska
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, University Hospital Muenster, Muenster, Germany
| |
Collapse
|
31
|
Vondrys D, Anton-Pacheco Sanchez J. Letter to the Editor regarding "Biodegradable airway stents in infants - Potential life-threatening pitfalls". Int J Pediatr Otorhinolaryngol 2017; 98:174. [PMID: 28390659 DOI: 10.1016/j.ijporl.2017.03.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 03/29/2017] [Indexed: 10/19/2022]
Affiliation(s)
- David Vondrys
- Department of Paediatric Cardiothoracic Surgery, Our Lady's Children Hospital Crumlin, Dublin, Ireland.
| | - Juan Anton-Pacheco Sanchez
- Pediatric Airway Unit, Division of Pediatric Surgery, Hospital Universitario 12 de Octubre, Universidad Complutense de Madrid, c/Vallehermoso 20. 7° A, izda, Madrid 28015, Spain
| |
Collapse
|
32
|
Response to the letter to the Editor "Biodegradable airway stents in infants - Potential life-threating pitfalls". Int J Pediatr Otorhinolaryngol 2017; 98:175-176. [PMID: 28410847 DOI: 10.1016/j.ijporl.2017.03.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2017] [Accepted: 03/29/2017] [Indexed: 11/22/2022]
|