1
|
Nuijens AC, Oei AL, Franken NAP, Rasch CRN, Stalpers LJA. Towards Personalized Radiotherapy in Pelvic Cancer: Patient-Related Risk Factors for Late Radiation Toxicity. Curr Oncol 2025; 32:47. [PMID: 39851963 PMCID: PMC11763857 DOI: 10.3390/curroncol32010047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 01/10/2025] [Accepted: 01/15/2025] [Indexed: 01/26/2025] Open
Abstract
Normal tissue reactions vary significantly among patients receiving the same radiation treatment regimen, reflecting the multifactorial etiology of late radiation toxicity. Predicting late radiation toxicity is crucial, as it aids in the initial decision-making process regarding the treatment modalities. For patients undergoing radiotherapy, anticipating late toxicity allows for planning adjustments to optimize individualized care. Various dosimetric parameters have been shown to influence the incidence of late toxicity, and the literature available on this topic is extensive. This narrative review examines patient-related determinants of late toxicity following external beam radiotherapy for pelvic tumors, with a focus on prostate and cervical cancer patients. In Part I, we address various methods for quantifying radiation toxicity, providing context for interpreting toxicity data. Part II examines the current insights into the clinical risk factors for late toxicity. While certain factors-such as previous abdominal surgery, smoking behavior, and severe acute toxicity-have consistently been reported, most of the others show inconsistent associations. In Part III, we explore the influence of genetic factors and discuss promising predictive assays. Single-nucleotide polymorphisms (SNPs) likely elevate the risk in specific combinations. Advances in artificial intelligence now allow for the identification of SNP patterns from large datasets, supporting the development of polygenic risk scores. These innovations hold promise for improving personalized treatment strategies and reducing the burden of late toxicity in cancer survivors.
Collapse
Affiliation(s)
- Anna C. Nuijens
- Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands (L.J.A.S.)
- Laboratory for Experimental Oncology and Radiobiology (LEXOR), Center for Experimental and Molecular Medicine (CEMM), Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Meibergdreef, 1105 AZ Amsterdam, The Netherlands
| | - Arlene L. Oei
- Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands (L.J.A.S.)
- Laboratory for Experimental Oncology and Radiobiology (LEXOR), Center for Experimental and Molecular Medicine (CEMM), Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands
| | - Nicolaas A. P. Franken
- Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands (L.J.A.S.)
- Laboratory for Experimental Oncology and Radiobiology (LEXOR), Center for Experimental and Molecular Medicine (CEMM), Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands
| | - Coen R. N. Rasch
- Department of Radiation Oncology, Leiden University Medical Center, Albinusdreef, 2333 ZA Leiden, The Netherlands
| | - Lukas J. A. Stalpers
- Department of Radiation Oncology, Amsterdam UMC Location University of Amsterdam, Meibergdreef, 1105 AZ Amsterdam, The Netherlands (L.J.A.S.)
| |
Collapse
|
2
|
Song D, Dabkowski M, Costa P, Nurani R, Kos M, Vanneste B, Magel D, Sapir E, Zimberg S, Boychak O, Soffen E, Alhasso A, Tokita K, Wang D, Symon Z, Hudes R. Prospective, Randomized Controlled Pivotal Trial of Biodegradable Balloon Rectal Spacer for Prostate Radiation Therapy. Int J Radiat Oncol Biol Phys 2024; 120:1410-1420. [PMID: 39032758 DOI: 10.1016/j.ijrobp.2024.07.2145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 07/02/2024] [Accepted: 07/04/2024] [Indexed: 07/23/2024]
Abstract
PURPOSE/OBJECTIVES Rectal spacers have been shown to reduce rectal side effects in patients receiving prostate radiation. However, concerns remain regarding precise and reproducible gel injection. We evaluated efficacy and safety of a novel rectoprostatic spacer balloon that allows potential for controlled, adaptable deployment. This study tested co-primary hypotheses: (1) balloon spacer would result in ≥25% reduction of rectal V70 in >75% of subjects and (2) implantation procedure-related and rectal ≥grade 1 adverse events within 6 months (duration ≥2 days, Common Terminology Criteria for Adverse Events 4.0) would be noninferior in balloon versus control subjects. METHODS AND MATERIALS A total of 222 subjects were enrolled at 16 centers. All patients had T1-T3 prostate cancer without magnetic resonance imaging evidence of posterior extraprostatic invasion. Randomization was 2:1 (balloon: control) and subject-blinded. Patients underwent transperineal transrectal ultrasound axial and sagittal-guided fiducial placement ± balloon, followed by Intensity-Modulated Radiation Therapy (81 Gy in 1.8 Gy fractions or biologically equivalent hypofractionated dose). For efficacy comparisons, plans were generated by a central core lab on pre- and postimplant computed tomography scans. RESULTS The primary efficacy endpoint was met, with 97.9% of balloon subjects (139/142) having rectal V70 reduction >25% (P < .001). Mean V70 was 7.0 % pre- versus 1.1% postimplant. The primary safety endpoint was met with balloon subjects experiencing fewer ≥grade 1 events, 18% versus 23% (P < .001 for noninferiority). On predefined secondary endpoint of ≥grade 2 events, rates trended lower in balloon subjects (4.3% vs 6.5%, P = .527). Mean perirectal spacing was 19 ± 3.7 mm and maintained through radiation treatment (18 ± 3.9 mm). Balloon resorption was observed on 6-month computed tomography in 98.5% (133/135) of subjects. The Expanded Prostate Cancer Index quality of life instrument was collected throughout study, and did not differ statistically between the study arms. CONCLUSIONS Biodegradable rectal spacer balloon was effective in significantly reducing dose to rectum, and associated with decreased cumulative rectal plus implantation-related adverse events. Balloon resorption was consistently observed by 6 months.
Collapse
Affiliation(s)
- Daniel Song
- Johns Hopkins Sidney Kimmel Comprehensive Cancer Center, Baltimore, Maryland.
| | - Mateusz Dabkowski
- Department of Brachytherapy, Oncology Center Institute of Maria Skłodowska Curie (MCMCC), Warsaw, Poland
| | - Paulo Costa
- CUF Porto Instituto Rua Fonte das Sete Bicas, Senhora da Hora Matosinhos, Portugal
| | - Rizwan Nurani
- Western Radiation Oncology (WRO), B Campbell, California
| | - Michael Kos
- Northern Nevada Radiation Oncology, Reno, Nevada
| | - Ben Vanneste
- MAASTRO Clinic Dr. Tanslaan, Maastricht, The Netherlands
| | | | - Eli Sapir
- Ha-Refu'a St 7 Ashdod, Assuta, Israel
| | - Shawn Zimberg
- Advanced Radiation Centers of New York, Lake Success, New York
| | | | | | | | | | - Dian Wang
- Rush University Medical Center, Chicago, Illinois
| | - Zvi Symon
- Shiba Medical Center, Tel Hashomer, Israel
| | | |
Collapse
|
3
|
Takai K, Watanabe R, Hyogo KI, Ito Y, Minagawa N, Sato Y, Matsuda Y, Nemoto K. Treatment outcome of localized prostate cancer using transperineal ultrasound image-guided radiotherapy. Radiat Oncol 2024; 19:100. [PMID: 39090614 PMCID: PMC11292876 DOI: 10.1186/s13014-024-02490-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 07/16/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND We report the results of a retrospective analysis of localized prostate cancer (LPCa) treated with transperineal ultrasound image-guided radiotherapy (TPUS-IGRT). METHODS A total of 124 patients (median age: 74 y, 46-84 y) with LPCa who underwent TPUS-IGRT (Clarity Autoscan system; CAS, Elekta; Stockholm, Sweden) between April 2016 and October 2021 for curative/after hormone induction were enrolled. The number of patients by risk (National Comprehensive Cancer Network 2019) was 7, 25, 42, and 50 for low (LR), good intermediate (good IR), poor intermediate (poor IR), and high (HR)/very high (VHR), respectively. Ninety-five patients were given neoadjuvant hormonal therapy. The planning target volume margin setting was 3 mm for rectal in most cases, 5-7 mm for superior/inferior, and 5 mm for anterior/right/left. The principle prescribed dose is 74 Gy (LR), 76 Gy (good IR), and 76-78 Gy (poor IR or above). CAS was equipped with a real-time prostate intrafraction monitoring (RTPIFM) system. When a displacement of 2-3 mm or more was detected, irradiation was paused, and the patients were placed on standby for prostate reinstatement/recorrection. Of the 3135 fractions in 85 patients for whom RTPIFM was performed, 1008 fractions (32.1%) were recorrected at least once after starting irradiation. RESULTS A total of 123 patients completed the radiotherapy course. The 5-year overall survival rate was 95.9%. The 5-year biological prostate-specific antigen relapse-free survival rate (bPFS) was 100% for LR, 92.9% for intermediate IR, and 93.2% for HR/VHR (Phoenix method). The 5-year late toxicity rate of Grade 2+ was 7.4% for genitourinary (GU) and 6.5% for gastrointestinal (GI) organs. Comparing the ≤ 76 Gy group to the 78 Gy group for both GU and GI organs, the incidence was higher in the 78 Gy group for both groups. CONCLUSION These results suggest that TPUS-IGRT is well tolerated, as the bPFS and incidence of late toxicity are almost comparable to those reported by other sources of image-guided radiotherapy.
Collapse
Affiliation(s)
- Kenji Takai
- Department of Radiology, Yamagata City Hospital Saiseikan, Yamagata, Japan.
| | - Ryota Watanabe
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Ken-Ichi Hyogo
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Yuri Ito
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Nobuko Minagawa
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Yusuke Sato
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Yoshikazu Matsuda
- Central Radiology Center, Yamagata City Hospital Saiseikan, Yamagata, Japan
| | - Kenji Nemoto
- Department of Radiation Oncology, Yamagata University, Yamagata, Japan
| |
Collapse
|
4
|
Lund JÅ, Lydersen S, Aksnessæther B, Solberg A, Wanderås A, Lervåg C, Kaasa S, Tøndel H. Image guided radiotherapy in curative treatment for prostate cancer. 5-year results from a randomized controlled trial (RIC-trial). Radiother Oncol 2024; 196:110309. [PMID: 38670265 DOI: 10.1016/j.radonc.2024.110309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 04/16/2024] [Accepted: 04/19/2024] [Indexed: 04/28/2024]
Abstract
BACKGROUND Between 2012 and 2015 we conducted a randomized controlled trial in prostate cancer patients comparing weekly 2-D portal imaging versus daily 3-D verification. AIM To evaluate the clinical outcomes of image guided radiotherapy by presenting rectal and urinary side effects, health related quality of life and progression free survival after 5-years follow up of a randomized controlled trial. METHODS We randomized 260 men with intermediate or high-risk prostate cancer to weekly 2-D portal imaging with 15 mm margin from CTV to PTV (Arm A) or daily 3-D cone-beam computer tomography with 7 mm margins (Arm B). Prescribed doses were 78 Gy/39 fractions. All patients received hormonal therapy. Primary end point was patient reported bowel symptoms and secondary outcomes were patient reported urinary symptoms, health- related quality of life and progression free survival. RESULTS Of the 216 patients available for analyses at 5 years more than 90 % completed patient reported outcome measures. There were no significant differences between study arms for any single items nor scales evaluating bowel symptoms. There were also no differences in self-reported urinary symptoms nor in health-related quality of life. Symptom scores were low in both study arms. Progression free survival was similar in Arm B as compared to arm A (Hazard ratio 1.01; 95 % CI 0.57 to 1.97). CONCLUSIONS Our results support that both 2-D weekly and 3-D daily image guided radiotherapy are safe and efficient treatments for PC and emphasize the need to evaluate technological progress in clinical trials with long follow-up.
Collapse
Affiliation(s)
- Jo-Åsmund Lund
- Clinic for Cancer Treatment and Rehabilitation, Helse Møre and Romsdal Hospital Trust, Ålesund, Norway; Department of Health Sciences, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Ålesund, Norway.
| | - Stian Lydersen
- Regional Centre for Child and Youth Mental Health and Child Welfare, Norwegian University of Science and Technology, Trondheim, Norway
| | - Bjørg Aksnessæther
- Clinic for Cancer Treatment and Rehabilitation, Helse Møre and Romsdal Hospital Trust, Ålesund, Norway
| | - Arne Solberg
- Cancer Clinic, St. Olavs Hospital Trust, Trondheim University Hospital, Trondheim, Norway; Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Anne Wanderås
- Cancer Clinic, St. Olavs Hospital Trust, Trondheim University Hospital, Trondheim, Norway
| | - Christoffer Lervåg
- Clinic for Cancer Treatment and Rehabilitation, Helse Møre and Romsdal Hospital Trust, Ålesund, Norway
| | - Stein Kaasa
- European Palliative Care Research Centre, Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway; European Palliative Care Research Centre, Department of Oncology, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway
| | - Hanne Tøndel
- Cancer Clinic, St. Olavs Hospital Trust, Trondheim University Hospital, Trondheim, Norway
| |
Collapse
|
5
|
Gao RW, Ma J, Pisansky TM, Kruse JJ, Stish BJ, Kowalchuk RO, McMenomy BP, Waddle MR, Phillips RM, Choo R, Davis BJ. Dosimetric Features of Ultra-Hypofractionated Intensity Modulated Proton Therapy for Prostate Cancer. Int J Part Ther 2024; 12:100015. [PMID: 38827121 PMCID: PMC11137510 DOI: 10.1016/j.ijpt.2024.100015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/08/2024] [Accepted: 03/06/2024] [Indexed: 06/04/2024] Open
Abstract
Purpose To report clinical and dosimetric characteristics of 5-fraction stereotactic ablative radiotherapy (SABR) using intensity modulated proton therapy (IMPT) for localized prostate cancer. Materials and Methods All patients receiving IMPT SABR from 2017 to 2021 for localized prostate cancer at our institution were included. Five fractions were delivered every other day to the prostate +/- seminal vesicles [clinical target volume (CTV)] with 3 mm/3% robustness. A 4-field arrangement with 2 anterior oblique and 2 opposed lateral beams was used in most patients (97%), and most (99%) had a retroprostatic hydrogel spacer. Results A total of 534 patients with low (14%), favorable intermediate (45%), unfavorable intermediate (36%), high (4.0%), or very high-risk (0.6%) disease are evaluated. Prescription dose was 36.25 Gy (31%), 38 Gy (38%), or 40 Gy (31%) was prescribed. Median volume percentage of CTV receiving at least 100% of prescription dose [V100% (%)] was 100% [interquartile range: 99.99-100]. Rectum V50% (%), V80% (%), and V90% (%) were significantly lower in patients who had spacer, with a mean difference of -9.70%, -6.59%, and -4.42%, respectively, compared to those who did not have spacer. Femoral head dose was lower with a 4-field arrangement. Mean differences in left and right femoral head V40% (%) were -6.99% and -10.74%, respectively. Conclusion We provide a large, novel report of patients treated with IMPT SABR for localized prostate cancer. Four-field IMPT with hydrogel spacer provides significant sparing of rectum and femoral heads without compromising target coverage.
Collapse
Affiliation(s)
- Robert W. Gao
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Jiasen Ma
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Thomas M. Pisansky
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Jon J. Kruse
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Bradley J. Stish
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Roman O. Kowalchuk
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Mark R. Waddle
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Ryan M. Phillips
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Richard Choo
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Brian J. Davis
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
6
|
Costa P, Vale J, Fonseca G, Costa A, Kos M. Use of rectal balloon spacer in patients with localized prostate cancer receiving external beam radiotherapy. Tech Innov Patient Support Radiat Oncol 2024; 29:100237. [PMID: 38322778 PMCID: PMC10846399 DOI: 10.1016/j.tipsro.2024.100237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 01/10/2024] [Accepted: 01/10/2024] [Indexed: 02/08/2024] Open
Abstract
Objective To evaluate the efficacy of the balloon spacer when used to reduce the radiation dose delivered to the rectum in prostate cancer patients undergoing external beam radiotherapy. Method A single center retrospective analysis including 75 PC patients with localized T1-T3a disease who received balloon spacer followed by EBRT. Pre- and post-implantation computed tomography (CT) scans were utilized for treatment planning for standard EBRT (78-81 Gy in 1.8-2 Gy fractions). Rectal dosimetry was assessed using DVHs, and toxicities were graded with CTCAE v.4. Results A median (IQR) prostate-rectum separation resulted in 1.6 cm (1.4-2.0) post balloon spacer implantation. Overall, 90.6 % (68/75) of patients had a clinically significant 25 % relative reduction in the rectal with a median relative reduction of 91.8 % (71.2-98.6 %) at rV70. Three (4.0 %) patients reported mild procedural adverse events, anal discomfort and dysuria. Within 90 days post-implantation, five patients (6.67 %) and 1 patient (1.33 %) reported grade 1 and grade 2 rectal toxicities (anal pain, constipation, diarrhea and hemorrhoids). Genitourinary (GU) grade 1 toxicity was reported in 37 patients (49.33 %), with only one patient (1.33 %) experiencing grade 2 GU toxicity. No grade ≥ 3 toxicity was reported. Conclusion Balloon spacer implantation effectively increased prostate-rectum separation and associated with dosimetric gains EBRT for PC stage T1-T3a. Further controlled studies are required to ascertain whether this spacer allows for radiotherapy dose escalation and minimizes gastrointestinal (GI) toxicity.
Collapse
Affiliation(s)
- Paulo Costa
- CUF Porto Instituto, Rua Fonte das Sete Bicas, 170 - Piso -1 – 4460-188 SENHORA DA HORA, Porto Portugal
| | - Joana Vale
- CUF Porto Instituto, Rua Fonte das Sete Bicas, 170 - Piso -1 – 4460-188 SENHORA DA HORA, Porto Portugal
| | - Graça Fonseca
- CUF Porto Instituto, Rua Fonte das Sete Bicas, 170 - Piso -1 – 4460-188 SENHORA DA HORA, Porto Portugal
| | - Adelina Costa
- CUF Porto Instituto, Rua Fonte das Sete Bicas, 170 - Piso -1 – 4460-188 SENHORA DA HORA, Porto Portugal
| | - Michael Kos
- Brachytherapy Radiation Specialists Summit Cancer, 6506 Regal Ct., Reno, NV 99223, USA
| |
Collapse
|
7
|
Brand DH, Brüningk SC, Wilkins A, Naismith O, Gao A, Syndikus I, Dearnaley DP, Hall E, van As N, Tree AC, Gulliford S. Gastrointestinal Toxicity Prediction Not Influenced by Rectal Contour or Dose-Volume Histogram Definition. Int J Radiat Oncol Biol Phys 2023; 117:1163-1173. [PMID: 37433374 PMCID: PMC10680426 DOI: 10.1016/j.ijrobp.2023.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/01/2023] [Accepted: 07/03/2023] [Indexed: 07/13/2023]
Abstract
PURPOSE Rectal dose delivered during prostate radiation therapy is associated with gastrointestinal toxicity. Treatment plans are commonly optimized using rectal dose-volume constraints, often whole-rectum relative-volumes (%). We investigated whether improved rectal contouring, use of absolute-volumes (cc), or rectal truncation might improve toxicity prediction. METHODS AND MATERIALS Patients from the CHHiP trial (receiving 74 Gy/37 fractions [Fr] vs 60 Gy/20 Fr vs 57 Gy/19 Fr) were included if radiation therapy plans were available (2350/3216 patients), plus toxicity data for relevant analyses (2170/3216 patients). Whole solid rectum relative-volumes (%) dose-volume-histogram (DVH), as submitted by treating center (original contour), was assumed standard-of-care. Three investigational rectal DVHs were generated: (1) reviewed contour per CHHiP protocol; (2) original contour absolute volumes (cc); and (3) truncated original contour (2 versions; ±0 and ±2 cm from planning target volume [PTV]). Dose levels of interest (V30, 40, 50, 60, 70, 74 Gy) in 74 Gy arm were converted by equivalent-dose-in-2 Gy-Fr (EQD2α/β= 3 Gy) for 60 Gy/57 Gy arms. Bootstrapped logistic models predicting late toxicities (frequency G1+/G2+, bleeding G1+/G2+, proctitis G1+/G2+, sphincter control G1+, stricture/ulcer G1+) were compared by area-undercurve (AUC) between standard of care and the 3 investigational rectal definitions. RESULTS The alternative dose/volume parameters were compared with the original relative-volume (%) DVH of the whole rectal contour, itself fitted as a weak predictor of toxicity (AUC range, 0.57-0.65 across the 8 toxicity measures). There were no significant differences in toxicity prediction for: (1) original versus reviewed rectal contours (AUCs, 0.57-0.66; P = .21-.98); (2) relative- versus absolute-volumes (AUCs, 0.56-0.63; P = .07-.91); and (3) whole-rectum versus truncation at PTV ± 2 cm (AUCs, 0.57-0.65; P = .05-.99) or PTV ± 0 cm (AUCs, 0.57-0.66; P = .27-.98). CONCLUSIONS We used whole-rectum relative-volume DVH, submitted by the treating center, as the standard-of-care dosimetric predictor for rectal toxicity. There were no statistically significant differences in prediction performance when using central rectal contour review, with the use of absolute-volume dosimetry, or with rectal truncation relative to PTV. Whole-rectum relative-volumes were not improved upon for toxicity prediction and should remain standard-of-care.
Collapse
Affiliation(s)
- Douglas H Brand
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
| | - Sarah C Brüningk
- Department of Health Science and Technology, ETH Zurich, Basel, Switzerland; Swiss Institute for Bioinformatics (SIB), Lausanne, Switzerland
| | - Anna Wilkins
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Urology Unit
| | - Olivia Naismith
- Radiotherapy Trials QA Group (RTTQA), Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Annie Gao
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Urology Unit
| | - Isabel Syndikus
- Radiotherapy Department, Clatterbridge Cancer Centre, Liverpool, United Kingdom
| | - David P Dearnaley
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Urology Unit
| | - Emma Hall
- Clinical Trials and Statistics Unit, The Institute of Cancer Research, London, United Kingdom
| | - Nicholas van As
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Urology Unit
| | - Alison C Tree
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Urology Unit
| | - Sarah Gulliford
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom; Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
8
|
Nasser N, Yang GQ, Koo J, Bowers M, Greco K, Feygelman V, Moros EG, Caudell JJ, Redler G. A head and neck treatment planning strategy for a CBCT-guided ring-gantry online adaptive radiotherapy system. J Appl Clin Med Phys 2023; 24:e14134. [PMID: 37621133 PMCID: PMC10691641 DOI: 10.1002/acm2.14134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/21/2023] [Accepted: 08/01/2023] [Indexed: 08/26/2023] Open
Abstract
PURPOSE A planning strategy was developed and the utility of online-adaptation with the Ethos CBCT-guided ring-gantry adaptive radiotherapy (ART) system was evaluated using retrospective data from Head-and-neck (H&N) patients that required clinical offline adaptation during treatment. METHODS Clinical data were used to re-plan 20 H&N patients (10 sequential boost (SEQ) with separate base and boost plans plus 10 simultaneous integrated boost (SIB)). An optimal approach, robust to online adaptation, for Ethos-initial plans using clinical goal prioritization was developed. Anatomically-derived isodose-shaping helper structures, air-density override, goals for controlling hotspot location(s), and plan normalization were investigated. Online adaptation was simulated using clinical offline adaptive simulation-CTs to represent an on-treatment CBCT. Dosimetric comparisons were based on institutional guidelines for Clinical-initial versus Ethos-initial plans and Ethos-scheduled versus Ethos-adapted plans. Timing for five components of the online adaptive workflow was analyzed. RESULTS The Ethos H&N planning approach generated Ethos-initial SEQ plans with clinically comparable PTV coverage (average PTVHigh V100% = 98.3%, Dmin,0.03cc = 97.9% and D0.03cc = 105.5%) and OAR sparing. However, Ethos-initial SIB plans were clinically inferior (average PTVHigh V100% = 96.4%, Dmin,0.03cc = 93.7%, D0.03cc = 110.6%). Fixed-field IMRT was superior to VMAT for 93.3% of plans. Online adaptation succeeded in achieving conformal coverage to the new anatomy in both SEQ and SIB plans that was even superior to that achieved in the initial plans (which was due to the changes in anatomy that simplified the optimization). The average adaptive workflow duration for SIB, SEQ base and SEQ boost was 30:14, 22.56, and 14:03 (min: sec), respectively. CONCLUSIONS With an optimal planning approach, Ethos efficiently auto-generated dosimetrically comparable and clinically acceptable initial SEQ plans for H&N patients. Initial SIB plans were inferior and clinically unacceptable, but adapted SIB plans became clinically acceptable. Online adapted plans optimized dose to new anatomy and maintained target coverage/homogeneity with improved OAR sparing in a time-efficient manner.
Collapse
Affiliation(s)
- Nour Nasser
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
- Department of PhysicsUniversity of South FloridaTampaFloridaUSA
| | - George Q. Yang
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
| | - Jihye Koo
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
- Department of PhysicsUniversity of South FloridaTampaFloridaUSA
| | - Mark Bowers
- Department of PhysicsUniversity of South FloridaTampaFloridaUSA
| | - Kevin Greco
- Department of PhysicsUniversity of South FloridaTampaFloridaUSA
| | | | - Eduardo G. Moros
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
| | - Jimmy J. Caudell
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
| | - Gage Redler
- Department of Radiation OncologyMoffitt Cancer CenterTampaFloridaUSA
| |
Collapse
|
9
|
Liu H, Schaal D, Curry H, Clark R, Magliari A, Kupelian P, Khuntia D, Beriwal S. Review of cone beam computed tomography based online adaptive radiotherapy: current trend and future direction. Radiat Oncol 2023; 18:144. [PMID: 37660057 PMCID: PMC10475190 DOI: 10.1186/s13014-023-02340-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 08/25/2023] [Indexed: 09/04/2023] Open
Abstract
Adaptive radiotherapy (ART) was introduced in the late 1990s to improve the accuracy and efficiency of therapy and minimize radiation-induced toxicities. ART combines multiple tools for imaging, assessing the need for adaptation, treatment planning, quality assurance, and has been utilized to monitor inter- or intra-fraction anatomical variations of the target and organs-at-risk (OARs). Ethos™ (Varian Medical Systems, Palo Alto, CA), a cone beam computed tomography (CBCT) based radiotherapy treatment system that uses artificial intelligence (AI) and machine learning to perform ART, was introduced in 2020. Since then, numerous studies have been done to examine the potential benefits of Ethos™ CBCT-guided ART compared to non-adaptive radiotherapy. This review will explore the current trends of Ethos™, including improved CBCT image quality, a feasible clinical workflow, daily automated contouring and treatment planning, and motion management. Nevertheless, evidence of clinical improvements with the use of Ethos™ are limited and is currently under investigation via clinical trials.
Collapse
Affiliation(s)
- Hefei Liu
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, USA
- Varian Medical Systems Inc, Palo Alto, CA, USA
| | | | | | - Ryan Clark
- Varian Medical Systems Inc, Palo Alto, CA, USA
| | | | | | | | - Sushil Beriwal
- Varian Medical Systems Inc, Palo Alto, CA, USA.
- Allegheny Health Network Cancer Institute, Pittsburgh, PA, USA.
| |
Collapse
|
10
|
Akay SU, Çetin İA, Bekiroğlu GN. Dosimetric analysis of patients receiving radiotherapy with VMAT technique in localized prostate cancer and its correlation with side effects. J Cancer Res Ther 2023; 19:801-807. [PMID: 37470614 DOI: 10.4103/jcrt.jcrt_1621_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Aim The aim was to study the relationship between dosimetric data of localized prostate cancer patients who have been treated with curative radiotherapy (RT) and gastrointestinal (GIS), genitourinary (GUS), anal and sexual side effects, and whether there was a difference between dosimetric data and clinical findings between risk groups. Methods Eighty-seven patients who received curative radiotherapy for localized prostate cancer between 2014 and 2019 were included in the study. Dosimetrically; whether there was a relationship between V30, V40, V50, V60, V65, V70, V75 for rectum and bladder; D90 for the penile bulb, V72, V74, V76 for the bulbomembranous urethra, V30, V45, V53, Dmax for the anus, and V45 (cc) for the intestine data and the side effects were analyzed. It was evaluated whether there was a relationship between testosterone values and sexual side effects. The Kolmogorov-Smirnov test, one-way analysis of variance (ANOVA) (F-test), and paired-sample t-test were used as statistical methods. For statistical significance, P < 0.05 was accepted. Results : The mean age of the patients was 69 (50-86), the mean Prostat specific antigen (PSA) (ng/dL) before RT was 25.1 (0.9-339), the median RT dose was 76 Gy (74-78 Gy), and the mean follow-up period was 38.2 months. PTVmax, PTVmean, PTVmin, bladder V40, bladder V50, rectum V30, rectum V40, rectum V50, and intestinal V45 (cc) were determined as dosimetric data showing differences between risk groups. A statistically significant relationship was found between rectum V30 (P = 0.017), V60 (P = 0.019), V65 (P = 0.008), V70 (P = 0.007), and V75 (P = 0.034) and chronic GIS side effects. G2 GIS side effects were observed in four patients (4.6%) in the entire patient group during the acute period. A statistically significant relationship was found between the patients receiving hormonotherapy (P = 0.021) and testosterone values at the last control (P ≤ 0.001) and chronic sexual side effects. Conclusion Attention should be paid to the rectum V30, V60, V65, V70, and V75 values to minimize the long-term GIS side effects in patients who have undergone RT. Testosterone level and ADT status affect chronic sexual toxicity.
Collapse
Affiliation(s)
- Sitki U Akay
- Marmara University Radiation Oncology Department, Marmara University, İstanbul, Turkey
| | - İlknur A Çetin
- Marmara University Radiation Oncology Department, Marmara University, İstanbul, Turkey
| | - Gülnaz N Bekiroğlu
- Marmara University Biostatistics Department, Marmara University, İstanbul, Turkey
| |
Collapse
|
11
|
Yang Q, Qin B, Hou W, Qin H, Yin F. Pathogenesis and therapy of radiation enteritis with gut microbiota. Front Pharmacol 2023; 14:1116558. [PMID: 37063268 PMCID: PMC10102376 DOI: 10.3389/fphar.2023.1116558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 03/07/2023] [Indexed: 04/03/2023] Open
Abstract
Radiotherapy is widely used in clinic due to its good effect for cancer treatment. But radiotherapy of malignant tumors in the abdomen and pelvis is easy to cause radiation enteritis complications. Gastrointestinal tract contains numerous microbes, most of which are mutualistic relationship with the host. Abdominal radiation results in gut microbiota dysbiosis. Microbial therapy can directly target gut microbiota to reverse microbiota dysbiosis, hence relieving intestinal inflammation. In this review, we mainly summarized pathogenesis and novel therapy of the radiation-induced intestinal injury with gut microbiota dysbiosis and envision the opportunities and challenges of radiation enteritis therapy.
Collapse
Affiliation(s)
- Qilin Yang
- Research Institute of Intestinal Diseases, Shanghai Tenth People’s Hospital, Tongji University, Shanghai, China
- School of Clinical Medicine of Nanjing Medical University, Nanjing, China
| | - Bingzhi Qin
- Research Institute of Intestinal Diseases, Shanghai Tenth People’s Hospital, Tongji University, Shanghai, China
| | - Weiliang Hou
- Research Institute of Intestinal Diseases, Shanghai Tenth People’s Hospital, Tongji University, Shanghai, China
- Shanghai Cancer Institute, Renji Hospital School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- *Correspondence: Weiliang Hou, ; Huanlong Qin, ; Fang Yin,
| | - Huanlong Qin
- Research Institute of Intestinal Diseases, Shanghai Tenth People’s Hospital, Tongji University, Shanghai, China
- *Correspondence: Weiliang Hou, ; Huanlong Qin, ; Fang Yin,
| | - Fang Yin
- Research Institute of Intestinal Diseases, Shanghai Tenth People’s Hospital, Tongji University, Shanghai, China
- *Correspondence: Weiliang Hou, ; Huanlong Qin, ; Fang Yin,
| |
Collapse
|
12
|
Ahmad Khalil D, Wulff J, Jazmati D, Geismar D, Bäumer C, Kramer PH, Steinmeier T, Schleithoff SS, Tschirdewahn S, Hadaschik B, Timmermann B. Is an Endorectal Balloon Beneficial for Rectal Sparing after Spacer Implantation in Prostate Cancer Patients Treated with Hypofractionated Intensity-Modulated Proton Beam Therapy? A Dosimetric and Radiobiological Comparison Study. Curr Oncol 2023; 30:758-768. [PMID: 36661707 PMCID: PMC9857887 DOI: 10.3390/curroncol30010058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/21/2022] [Accepted: 12/29/2022] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND The aim of this study is to examine the dosimetric influence of endorectal balloons (ERB) on rectal sparing in prostate cancer patients with implanted hydrogel rectum spacers treated with dose-escalated or hypofractionated intensity-modulated proton beam therapy (IMPT). METHODS Ten patients with localized prostate cancer included in the ProRegPros study and treated at our center were investigated. All patients underwent placement of hydrogel rectum spacers before planning. Two planning CTs (with and without 120 cm3 fluid-filled ERB) were applied for each patient. Dose prescription was set according to the h strategy, with 72 Gray (Gy)/2.4 Gy/5× weekly to prostate + 1 cm of the seminal vesicle, and 60 Gy/2 Gy/5× weekly to prostate + 2 cm of the seminal vesicle. Planning with two laterally opposed IMPT beams was performed in both CTs. Rectal dosimetry values including dose-volume statistics and normal tissue complication probability (NTCP) were compared for both plans (non-ERB plans vs. ERB plans). RESULTS For ERB plans compared with non-ERB, the reductions were 8.51 ± 5.25 Gy (RBE) (p = 0.000) and 15.76 ± 11.11 Gy (p = 0.001) for the mean and the median rectal doses, respectively. No significant reductions in rectal volumes were found after high dose levels. The use of ERB resulted in significant reduction in rectal volume after receiving 50 Gy (RBE), 40 Gy (RBE), 30 Gy (RBE), 20 Gy (RBE), and 10 Gy (RBE) with p values of 0.034, 0.008, 0.003, 0.001, and 0.001, respectively. No differences between ERB and non-ERB plans for the anterior rectum were observed. ERB reduced posterior rectal volumes in patients who received 30 Gy (RBE), 20 Gy (RBE), or 10 Gy (RBE), with p values of 0.019, 0.003, and 0.001, respectively. According to the NTCP models, no significant reductions were observed in mean or median rectal toxicity (late rectal bleeding ≥ 2, necrosis or stenosis, and late rectal toxicity ≥ 3) when using the ERB. CONCLUSION ERB reduced rectal volumes exposed to intermediate or low dose levels. However, no significant reduction in rectal volume was observed in patients receiving high or intermediate doses. There was no benefit and also no disadvantage associated with the use of ERB for late rectal toxicity, according to available NTCP models.
Collapse
Affiliation(s)
- Dalia Ahmad Khalil
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany
| | - Jörg Wulff
- Faculty of Physics, TU Dortmund University, 44227 Dortmund, Germany
| | - Danny Jazmati
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany
| | - Dirk Geismar
- Faculty of Physics, TU Dortmund University, 44227 Dortmund, Germany
| | - Christian Bäumer
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany
| | | | - Theresa Steinmeier
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany
| | | | - Stephan Tschirdewahn
- Department of Urology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany
| | - Boris Hadaschik
- Department of Urology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany
| | - Beate Timmermann
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany
- Faculty of Physics, TU Dortmund University, 44227 Dortmund, Germany
- German Cancer Consortium (DKTK), 45147 Essen, Germany
| |
Collapse
|
13
|
Williams J, Millan KM, Bolton D, Tan A, Cham CW, Pham T, Pan D, Liu M, Chan Y, Manohar P, Thomas J, Koufogiannis G, Ho H, Guerrieri M, Ng M, Boike T, Macleod C, Joon DL, Foroudi F, Chao M. Hyaluronic acid rectal spacer in EBRT: Usability, safety and symmetry related to user experience. J Med Imaging Radiat Sci 2022; 53:640-647. [PMID: 36202722 DOI: 10.1016/j.jmir.2022.09.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 09/02/2022] [Accepted: 09/13/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVES To report on the usability, safety, symmetry, and effectiveness of hyaluronic acid (HA) injected between the prostate and the rectum for patients undergoing treatment for prostate cancer with external beam radiotherapy (EBRT), and present a novel definition of rectal spacer symmetry that is reproducible and independent of patient anatomy. PATIENTS AND METHODS 102 consecutive patients with clinical stage of T1c-3b prostate cancer underwent general anaesthesia for fiducial marker insertion and injection of HA into the perirectal space before EBRT. HA safety, symmetry, separation, and usability based on user experience were assessed. RESULTS HA insertion was completed with a 100% success rate independent of user experience, rated as 'easy' or 'very easy' in all cases. There were no postoperative complications reported. The mean (SD) recto-prostatic separation for all patients at the base, midgland and apex were 12 (±2) mm, 11 (±2) mm, and 9 (±1) mm respectively. The mean sagittal length of the implant was 43 (±5) mm. The implant was rated as symmetrical in 98% of cases. The mean rV70Gy was 1.6% (IQR 0.8-3.3%) for patients receiving 78-80Gy. The mean rV53Gy was 2.8% (IQR 1.2-4.8%) for patients receiving 60-62Gy. The median prostate size was 43.5 cc (IQR 32-57). CONCLUSION Injection of HA was able to achieve highly symmetrical recto-prostatic separation, with new users able to produce excellent separation, particularly at the apex, achieving similar dosimetry outcomes as competent and experienced users. HA is safe, easy to use, and significantly reduced mean rV70Gy and rV53Gy compared to non-spacer patients.
Collapse
Affiliation(s)
- Jack Williams
- Albury Wodonga Health, 201 Borella Rd, Albury, NSW 2640, Australia; Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Kevin Mc Millan
- Eastern Health, 5 Arnold Street, Box Hill, VIC 3128, Australia
| | - Damien Bolton
- Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
| | - Alwin Tan
- The Bays Hospital, 262 Main St, Mornington, VIC 3931, Australia
| | - Chee Wee Cham
- The Bays Hospital, 262 Main St, Mornington, VIC 3931, Australia
| | - Trung Pham
- Monash Health, 246, Clayton Rd, Clayton, VIC 3168, Australia
| | - David Pan
- Monash Health, 246, Clayton Rd, Clayton, VIC 3168, Australia
| | - Madalena Liu
- Monash Health, 246, Clayton Rd, Clayton, VIC 3168, Australia
| | - Yee Chan
- Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
| | - Paul Manohar
- Monash Health, 246, Clayton Rd, Clayton, VIC 3168, Australia
| | - Joe Thomas
- Eastern Health, 5 Arnold Street, Box Hill, VIC 3128, Australia
| | - George Koufogiannis
- Ringwood Private Hospital, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Huong Ho
- Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Mario Guerrieri
- Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Michael Ng
- Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Thomas Boike
- Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia; Michigan Health Professionals Radiation Oncology, 4550 Investment Dr, Suite B111, Troy, MI 8098, US
| | - Craig Macleod
- Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia
| | - Daryl Lim Joon
- Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
| | - Farshad Foroudi
- Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
| | - Michael Chao
- Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia; Ringwood Private Hospital, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia; Genesis Care Victoria, 36 Mt Dandenong Rd, Ringwood East, VIC 3135, Australia.
| |
Collapse
|
14
|
Yang Y, Rwigema JCM, Vargas C, Yu NY, Keole SR, Wong WW, Schild SE, Bues M, Liu W, Shen J. Technical note: Investigation of dose and LET d effect to rectum and bladder by using non-straight laterals in prostate cancer receiving proton therapy. Med Phys 2022; 49:7428-7437. [PMID: 36208196 DOI: 10.1002/mp.16008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/02/2022] [Accepted: 09/22/2022] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Parallel-opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated. PURPOSE To investigate the dose and dose averaged LET (LETd ) impact of using new beam arrangements rotating beams 5°-15° posteriorly to the laterals in prostate cancer treated with pencil-beam-scanning (PBS) proton therapy. METHODS Twenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel-opposed lateral beams. Dose-volume histograms (DVHs) from posterior oblique beams were analyzed. Dose-LETd -volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, V ( d , l ) $V( {d,l} )$ , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two-sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed-rank test. RESULTS Rotating beam angles from laterals to slightly posterior by 5°-15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01). CONCLUSIONS Posterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.
Collapse
Affiliation(s)
- Yunze Yang
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | | | - Carlos Vargas
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Nathan Y Yu
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Sameer R Keole
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - William W Wong
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Steven E Schild
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Martin Bues
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Wei Liu
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Jiajian Shen
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| |
Collapse
|
15
|
Hervás-Morón A, Domínguez-Rullán J, Santana VD, Valero M, Vallejo C, Sancho S, Fuentes JDG, Cámara Gallego M, López-Campos F. Assessing radiation dose for postoperative radiotherapy in prostate cancer: Real world data. World J Clin Oncol 2022; 13:652-662. [PMID: 36157159 PMCID: PMC9346429 DOI: 10.5306/wjco.v13.i7.652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 06/04/2022] [Accepted: 07/06/2022] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Approximately 30% of patients with localized prostate cancer (PCa) who undergo radical prostatectomy will develop biochemical recurrence. In these patients, the only potentially curative treatment is postoperative radiotherapy (PORT) with or without hormone therapy. However, the optimal radiotherapy dose is unknown due to the limited data available.
AIM To determine whether the postoperative radiotherapy dose influences biochemical failure-free survival (BFFS) in patients with PCa.
METHODS Retrospective analysis of patients who underwent radical prostatectomy for PCa followed by PORT-either adjuvant radiotherapy (ART) or salvage radiotherapy (SRT)-between April 2002 and July 2015. From 2002 to 2010, the prescribed radiation dose to the surgical bed was 66-70 Gy in fractions of 2 Gy; from 2010 until July 2015, the prescribed dose was 70-72 Gy. Patients were grouped into three categories according to the total dose administered: 66-68 Gy, 70 Gy, and 72 Gy. The primary endpoint was BFFS, defined as the post-radiotherapy prostate-specific antigen (PSA) nadir + 0.2 ng/mL. Secondary endpoints were overall survival (OS), cancer-specific survival (CSS), and metastasis-free survival (MFS; based on conventional imaging tests). Treatment-related genitourinary (GU) and gastrointestinal (GI) toxicity was evaluated according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Finally, we aimed to identify potential prognostic factors. BFFS, OS, CSS, and MFS were calculated with the Kaplan-Meier method and the log-rank test. Univariate and multivariate Cox regression models were performed to explore between-group differences in survival outcome measures.
RESULTS A total of 301 consecutive patients were included. Of these, 93 (33.6%) received ART and 186 (66.4%) SRT; 22 patients were excluded due to residual macroscopic disease or local recurrence in the surgical bed. In this subgroup (n = 93), 43 patients (46.2%) were Gleason score (GS) ≤ 6, 44 (47.3%) GS 7, and 6 (6.5%) GS ≥ 8; clinical stage was cT1 in 51 (54.8%), cT2 in 35 (39.3%), and cT3 in one patient (1.1%); PSA was < 10 ng/mL in 58 (63%) patients, 10-20 ng/mL in 28 (30.6%), and ≥ 20 ng/mL in 6 (6.4%) patients. No differences were found in BFFS in this patient subset versus the entire cohort of patients (P = 0.66). At a median follow-up of 113 months (range, 4-233), 5- and 10-year BFFS rates were 78.8% and 73.7%, respectively, with OS rates of 93.3% and 81.4%. The 5-year BFFS rates in three groups were as follows: 69.6% (66-68 Gy), 80.5% (70 Gy) and 82.6% (72 Gy) (P = 0.12):the corresponding 10-year rates were 63.9%, 72.9%, and 82.6% (P = 0.12), respectively. No significant between-group differences were observed in MFS, CSS, or OS. On the univariate analysis, the following variables were significantly associated with BFFS: PSA at diagnosis; clinical stage (cT1 vs cT2); GS at diagnosis; treatment indication (ART vs SRT); pre-RT PSA levels; and RT dose 66 -68 Gy vs. 72 Gy (HR: 2.05; 95%CI: 1.02-4.02, P = 0.04). On the multivariate analysis, the following variables remained significant: biopsy GS (HR: 2.85; 95%CI: 1.83-4.43, P < 0.001); clinical stage (HR: 2.31; 95%CI: 1.47-4.43, P = 0.01); and treatment indication (HR: 4.11; 95%CI: 2.06-8.17, P < 0.001). Acute grade (G) 1 GU toxicity was observed in 11 (20.4%), 17 (19.8%), and 3 (8.3%) patients in each group (66-68 Gy, 70 Gy and 72 Gy), respectively (P = 0.295). Acute G2 toxicity was observed in 2 (3.7%), 4 (4.7%) and 2 (5.6%) patients, respectively (P = 0.949). Acute G1 GI toxicity was observed in 16 (29.6%), 23 (26.7%) and 2 (5.6%) patients in each group, respectively (P = 0.011). Acute G2 GI toxicity was observed in 2 (3.7%), 6 (6.9%) and 1 (2.8%) patients, respectively (P = 0.278). No cases of acute G3 GI toxicity were observed.
CONCLUSION The findings of this retrospective study suggest that postoperative radiotherapy dose intensification in PCa is not superior to conventional radiotherapy treatment.
Collapse
Affiliation(s)
- Asunción Hervás-Morón
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Jose Domínguez-Rullán
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Victor Duque Santana
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Mireia Valero
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Carmen Vallejo
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Sonsoles Sancho
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | | | - Miguel Cámara Gallego
- Department of Medical Physics, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| | - Fernando López-Campos
- Department of Radiation Oncology, Hospital Universitario Ramón Y Cajal, Madrid 28034, Spain
| |
Collapse
|
16
|
Ong AL, Knight K, Panettieri V, Dimmock M, Tuan JK, Tan HQ, Wright C. Dose-volume analysis of planned versus accumulated dose as a predictor for late gastrointestinal toxicity in men receiving radiotherapy for high-risk prostate cancer. Phys Imaging Radiat Oncol 2022; 23:97-102. [PMID: 35879938 PMCID: PMC9307677 DOI: 10.1016/j.phro.2022.07.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 07/02/2022] [Accepted: 07/06/2022] [Indexed: 11/26/2022] Open
Abstract
Interfractional variations in organs at risk were observed in prostate radiotherapy. Rectal accumulated dose was significantly higher at the intermediate-high dose region. Rectal planned dose was significantly higher at the very high dose region. Dose>78.2 Gy to 0.03 cc of rectum was predictive of late Grade 2 toxicity. Patient age>72 years was predictive of late Grade 2 rectal toxicity.
Background and purpose Significant dose deviations have been reported between planned (DP) and accumulated (DA) dose in prostate radiotherapy. This study aimed to develop multivariate analysis (MVA) models associating Grade 1 and 2 gastrointestinal (GI) toxicity with clinical and DP or DA dosimetric variables separately. Materials and methods Dose volume (DV) metrics were compared between DA and DP for 150 high-risk prostate cancer patients. MV models were generated from significant clinical and dosimetric variables (p < 0.05) at univariate level. Dose-based-region of interest (DB-ROI) metrics were included. Model performance was measured, and additional subgroup analysis were performed. Results Rectal DA demonstrated a higher intermediate-high dose (V30-65 Gy and DB-ROI at 15–50 mm) compared to DP. Conversely, at the very high dose region, rectal DA (V75 Gy and DB-ROI at 5–10 mm) were significantly lower. In MVA, rectal DB-ROI at 10 mm was predictive for Grade ≥ 1 GI toxicity for DA and DP. Age, rectal DA for D0.03 cc, and rectal DP for DB-ROI 10 mm were predictors for Grade 2 GI toxicity. Subgroup analysis revealed that patients ≥ 72 years old and a rectal DA of ≥ 78.2 Gy were highly predictive of Grade 2 GI toxicity. Conclusions The dosimetric impact of a higher dose rectal dose in DA due to volumetric changes was minimal and was not predictive of detrimental clinical toxicity apart from rectal D0.03 cc ≥ 78.2 Gy for Grade 2 GI toxicity. The use of the DB-ROI method can provide equivalent predictive power as the DV method in toxicity prediction.
Collapse
|
17
|
Kundu P, Lin EY, Yoon SM, Parikh NR, Ruan D, Kishan AU, Lee A, Steinberg ML, Chang AJ. Rectal Radiation Dose and Clinical Outcomes in Prostate Cancer Patients Treated With Stereotactic Body Radiation Therapy With and Without Hydrogel. Front Oncol 2022; 12:853246. [PMID: 35350564 PMCID: PMC8957858 DOI: 10.3389/fonc.2022.853246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 02/07/2022] [Indexed: 12/03/2022] Open
Abstract
Background Patients with prostate cancer treated with stereotactic body radiation therapy (SBRT) may experience gastrointestinal (GI) toxicity. The hydrogel may mitigate this toxicity by reducing the rectal radiation dose. The purpose of this study is to compare rectal radiation dose and GI toxicity in patients receiving prostate SBRT with and without hydrogel. Methods Consecutive patients treated with SBRT between February 2017 and January 2020 with and without hydrogel were retrospectively identified. Baseline characteristics including prostate volume, rectal diameter, body mass index (BMI), age, pretreatment prostate-specific antigen (PSA), Gleason score, T-stage, and androgen deprivation therapy (ADT) usage were compared. Dosimetric outcomes (V40Gy, V36Gy, V32Gy, V38Gy, and V20Gy), rates of acute (≤90 days) and late (>90 days) GI toxicity, and PSA outcomes were evaluated for patients with and without hydrogel. Results A total of 92 patients were identified (51 hydrogel and 41 non-hydrogel). There were no significant differences in baseline characteristics. Rectal V38(cc) was significantly less in the hydrogel group (mean 0.44 vs. mean 1.41 cc, p = 0.0002), and the proportion of patients with V38(cc) < 2 cc was greater in the hydrogel group (92% vs. 72%, p = 0.01). Rectal dose was significantly lower for all institutional dose constraints in the hydrogel group (p < 0.001). The hydrogel group experienced significantly less acute overall GI toxicity (16% hydrogel vs. 28% non-hydrogel, p = 0.006), while the difference in late GI toxicity trended lower with hydrogel but was not statistically significant (4% hydrogel vs. 10% non-hydrogel, p = 0.219). At a median follow-up of 14.8 months, there were no biochemical recurrences in either group. Conclusion Hydrogel reduces rectal radiation dose in patients receiving prostate SBRT and is associated with a decreased rate of acute GI toxicity.
Collapse
Affiliation(s)
- Palak Kundu
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Eric Y Lin
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States.,David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Stephanie M Yoon
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Neil R Parikh
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Dan Ruan
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Amar U Kishan
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Alan Lee
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Michael L Steinberg
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - Albert J Chang
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| |
Collapse
|
18
|
MRI-Based Radiotherapy Planning to Reduce Rectal Dose in Excess of Tolerance. Prostate Cancer 2022; 2022:7930744. [PMID: 35154830 PMCID: PMC8831048 DOI: 10.1155/2022/7930744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 12/15/2021] [Accepted: 12/28/2021] [Indexed: 11/18/2022] Open
Abstract
Materials and Methods This prospective single-arm study enrolled 15 men treated with IG-IMRT for localized prostate cancer. All participants received a dedicated 3 Tesla MRI examination of the prostate in addition to a pelvic CT examination for treatment planning. Two volumetric modulated arc therapy (VMAT) plans with a prescription dose of 79.2 Gy were designed using identical constraints based on CT- and MRI-defined consensus volumes. The volume of rectum exposed to 70 Gy or more was compared using the Wilcoxon paired signed rank test. Results For CT-based treatment plans, the median volume of rectum receiving 70 Gy or more was 9.3 cubic centimeters (cc) (IQR 7.0 to 10.2) compared with 4.9 cc (IQR 4.1 to 7.8) for MRI-based plans. This resulted in a median volume reduction of 2.1 cc (IQR 0.5 to 5.3, P < .001). Conclusions Using MRI to plan prostate IG-IMRT to a dose of 79.2 Gy reduces the volume of rectum receiving radiation dose in excess of tolerance (70 Gy or more) and should be considered in men who are at high risk for late rectal toxicity and are not good candidates for other rectal sparing techniques such as hydrogel spacer. This trial is registered with NCT02470910.
Collapse
|
19
|
Cellini F, Tagliaferri L, Frascino V, Alitto AR, Fionda B, Boldrini L, Romano A, Casà C, Catucci F, Mattiucci GC, Valentini V. Radiation therapy for prostate cancer: What's the best in 2021. Urologia 2022; 89:5-15. [PMID: 34496707 DOI: 10.1177/03915603211042335] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Radiotherapy is highly involved in the management of prostate cancer. Its features and potential applications experienced a radical evolution over last decades, as they are associated to the continuous evolution of available technology and current oncological innovations. Some application of radiotherapy like brachytherapy have been recently enriched by innovative features and multidisciplinary dedications. In this report we aim to put some questions regarding the following issues regarding multiple aspects of modern application of radiation oncology: the current application of radiation oncology; the modern role of stereotactic body radiotherapy (SBRT) for both the management of primary lesions and for lymph-nodal recurrence; the management of the oligometastatic presentations; the role of brachytherapy; the aid played by the application of the organ at risk spacer (spacer OAR), fiducial markers, electromagnetic tracking systems and on-line Magnetic Resonance guided radiotherapy (MRgRT), and the role of the new opportunity represented by radiomic analysis.
Collapse
Affiliation(s)
- Francesco Cellini
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia
| | - Luca Tagliaferri
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Vincenzo Frascino
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Anna Rita Alitto
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Bruno Fionda
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Luca Boldrini
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Angela Romano
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Calogero Casà
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | | | - Gian Carlo Mattiucci
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia
- Radiation Oncology, Mater Olbia Hospital, Olbia, Italy
| | - Vincenzo Valentini
- UOC di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia
| |
Collapse
|
20
|
Katz MS, Mihai A, Milano MT. A Dose of Reality: Embracing the Unseen to Improve Stereotactic Radiotherapy. Clin Oncol (R Coll Radiol) 2022; 34:395-397. [PMID: 35094939 DOI: 10.1016/j.clon.2022.01.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 12/30/2021] [Accepted: 01/11/2022] [Indexed: 12/24/2022]
Affiliation(s)
- M S Katz
- Department of Radiation Medicine, Lowell General Hospital, Lowell, MA, USA.
| | - A Mihai
- Department of Radiation Oncology, Beacon Hospital, Sandyford, Dublin, Ireland
| | - M T Milano
- Department of Radiation Oncology, University of Rochester Medical Center, Rochester, New York, USA
| |
Collapse
|
21
|
Dose Prediction Models Based on Geometric and Plan Optimization Parameter for Adjuvant Radiotherapy Planning Design in Cervical Cancer Radiotherapy. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:7026098. [PMID: 34804459 PMCID: PMC8604605 DOI: 10.1155/2021/7026098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 10/16/2021] [Indexed: 11/18/2022]
Abstract
The prediction of an additional space for the dose sparing of organs at risk (OAR) in radiotherapy is still difficult. In this pursuit, the present study was envisaged to find out the factors affecting the bladder and rectum dosimetry of cervical cancer. Additionally, the relationship between the dose-volume histogram (DVH) parameters and the geometry and plan dose-volume optimization parameters of the bladder/rectum was established to develop the dose prediction models and guide the planning design for lower OARs dose coverage directly. Thirty volume modulated radiation therapy (VMAT) plans from cervical cancer patients were randomly chosen to build the dose prediction models. The target dose coverage was evaluated. Dose prediction models were established by univariate and multiple linear regression among the dosimetric parameters of the bladder/rectum, the geometry parameters (planning target volume (PTV), volume of bladder/rectum, overlap volume of bladder/rectum (OV), and overlapped volume as a percentage of bladder/rectum volume (OP)), and corresponding plan dose-volume optimization parameters of the nonoverlapping structures (the structure of bladder/rectum outside the PTV (NOS)). Finally, the accuracy of the prediction models was evaluated by tracking d = (predicted dose-actual dose)/actual in additional ten VMAT plans. V 30, V 35, and V 40 of the bladder and rectum were found to be multiple linearly correlated with the relevant OP and corresponding dose-volume optimization parameters of NOS (regression R 2 > 0.99, P < 0.001). The variations of these models were less than 0.5% for bladder and rectum. Percentage of bladder and rectum within the PTV and the dose-volume optimization parameters of NOS could be used to predict the dose quantitatively. The parameters of NOS as a limited condition could be used in the plan optimization instead of limiting the dose and volume of the entire OAR traditionally, which made the plan optimization more unified and convenient and strengthened the plan quality and consistency.
Collapse
|
22
|
Fukumitsu N, Mima M, Demizu Y, Suzuki T, Ishida T, Matsushita K, Yamaguchi R, Fujisawa M, Soejima T. Separation effect and development of implantation technique of hydrogel spacer for prostate cancers. Pract Radiat Oncol 2021; 12:226-235. [PMID: 34801769 DOI: 10.1016/j.prro.2021.10.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 10/22/2021] [Accepted: 10/31/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE The purpose was to improve the placement of a hydrogel spacer in prostate cancer patients receiving radiotherapy. METHODS AND MATERIALS One hundred and sixty patients with prostate cancer were classified into 3 groups as follows: group 1, no spacer (n = 30); group 2, spacer placed using conventional technique (n = 100); and group 3, spacer placed using new technique (n = 30). When placing the spacer, the tip of the needle was placed at the middle of the prostate gland (group 2) or at a level corresponding to a cranial:caudal ratio of 6:4 and as close to the prostate gland as possible (group 3). The separation effect was then examined and compared among the groups. RESULTS The separation in group 2 was larger than that in group 1 from the base to the apex (4 mm) level of the prostate, while the separation in group 3 was larger than that in group 2 from the middle to the apex (4 mm) level of the prostate. The separation values for the middle to the apex, the spacer thickness from the apex (10 mm) level to the apex, the rectal exclusion from the middle to the apex, and the laterality were correlated with the 50 and 60 Gray relative biological effectiveness (Gy(RBE)) rectal dose (p = 4.1 × 10-9 - 0.046). The separation vales were strongly correlated with the spacer thickness at the apex (10 mm) and apex (4 mm) (p = 1.1 × 10-18 - 1.8 × 10-17). The rectal volumes at 10-60 Gy(RBE) differed among the groups (p = 5.1 × 10-19 - 5.4 × 10-3). The rectal volumes in group 2 were smaller than those in group 1 at all dose levels, while those in group 3 were smaller than those in group 2 at dose levels of 30-50 Gy(RBE). CONCLUSIONS The separation, spacer thickness and rectal exclusion from the middle to the apex of the prostate and the laterality of the hydrogel spacer affected the reduction in the rectal dose. The rectal dose can be further reduced by implanting a spacer on the caudal and the prostate side.
Collapse
Affiliation(s)
| | - Masayuki Mima
- Department of Radiation Oncology, Kobe Proton Center
| | - Yusuke Demizu
- Department of Radiation Oncology, Kobe Proton Center
| | | | - Takaki Ishida
- Department of Urology, International Clinical Cancer Research Center, Kobe University
| | - Kei Matsushita
- Department of Urology, International Clinical Cancer Research Center, Kobe University
| | - Raizo Yamaguchi
- Department of Urology, International Clinical Cancer Research Center, Kobe University
| | - Masato Fujisawa
- Department of Urology, Kobe University Graduate School of Medicine
| | | |
Collapse
|
23
|
Bhangoo RS, Petersen MM, Bulman GF, Vargas CE, Thorpe CS, Shen J, Wong WW, Rwigema JCM, Daniels TB, Keole SR, Schild SE, Rong Y, DeWees TA. Biologically Effective Dose and Rectal Bleeding in Definitive Proton Therapy for Prostate Cancer. Int J Part Ther 2021; 8:37-46. [PMID: 35530190 PMCID: PMC9009455 DOI: 10.14338/ijpt-21-00007.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 07/27/2021] [Indexed: 12/03/2022] Open
Abstract
Purpose and Objectives With increasing use of hypofractionation and extreme hypofractionation for prostate cancer, rectal dose-volume histogram (DVH) parameters that apply across dose fractionations may be helpful for treatment planning in clinical practice. We present an exploratory analysis of biologically effective rectal dose (BED) and equivalent rectal dose in 2 Gy fractions (EQD2) for rectal bleeding in patients treated with proton therapy across dose fractionations. Materials and Methods From 2016 to 2018, 243 patients with prostate cancer were treated with definitive proton therapy. Rectal DVH parameters were obtained from treatment plans, and rectal bleeding events were recorded. The BED and EQD2 transformations were applied to each rectal DVH parameter. Univariate analysis using logistic regression was used to determine DVH parameters that were significant predictors of grade ≥ 2 rectal bleeding. Youden index was used to determine optimum cutoffs for clinically meaningful DVH constraints. Stepwise model-selection criteria were then applied to fit a “best” multivariate logistic model for predicting Common Terminology Criteria for Adverse Events grade ≥ 2 rectal bleeding. Results Conventional fractionation, hypofractionation, and extreme hypofractionation were prescribed to 117 (48%), 84 (34%), and 42 (17.3%) patients, respectively. With a median follow-up of 20 (2.5-40) months, 10 (4.1%) patients experienced rectal bleeding. On univariate analysis, multiple rectal DVH parameters were significantly associated with rectal bleeding across BED, EQD2, and nominal doses. The BED volume receiving 55 Gy > 13.91% was found to be statistically and clinically significant. The BED volume receiving 55 Gy remained statistically significant for an association with rectal bleeding in the multivariate model (odds ratio, 9.81; 95% confidence interval, 2.4-40.5; P = .002). Conclusion In patients undergoing definitive proton therapy for prostate cancer, dose to the rectum and volume of the rectum receiving the dose were significantly associated with rectal bleeding across conventional fractionation, hypofractionation, and extreme hypofractionation when using BED and EQD2 transformations.
Collapse
Affiliation(s)
| | - Molly M. Petersen
- Department of Health Sciences Research, Mayo Clinic, Scottsdale, AZ, USA
| | | | | | | | - Jason Shen
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| | - William W. Wong
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| | | | | | - Sameer R. Keole
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| | | | - Yi Rong
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| | - Todd A. DeWees
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
- Department of Health Sciences Research, Mayo Clinic, Scottsdale, AZ, USA
| |
Collapse
|
24
|
Yang Y, Vargas CE, Bhangoo RS, Wong WW, Schild SE, Daniels TB, Keole SR, Rwigema JCM, Glass JL, Shen J, DeWees TA, Liu T, Bues M, Fatyga M, Liu W. Exploratory Investigation of Dose-Linear Energy Transfer (LET) Volume Histogram (DLVH) for Adverse Events Study in Intensity Modulated Proton Therapy (IMPT). Int J Radiat Oncol Biol Phys 2021; 110:1189-1199. [PMID: 33621660 DOI: 10.1016/j.ijrobp.2021.02.024] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 01/25/2021] [Accepted: 02/11/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE We proposed a novel tool-a dose linear energy transfer (LET)-volume histogram (DLVH)-and performed an exploratory study to investigate rectal bleeding in prostate cancer treated with intensity modulated proton therapy. METHODS AND MATERIALS The DLVH was constructed with dose and LET as 2 axes, and the normalized volume of the structure was contoured in the dose-LET plane as isovolume lines. We defined the DLVH index, DLv%(d,l) (ie, v% of the structure) to have a dose of ≥d Gy and an LET of ≥l keV/μm, similar to the dose-volume histogram index Dv%. Nine patients with prostate cancer with rectal bleeding (Common Terminology Criteria for Adverse Events grade ≥2) were included as the adverse event group, and 48 patients with no complications were considered the control group. A P value map was constructed by comparison of the DLVH indices of all patients between the 2 groups using the Mann-Whitney U test. Dose-LET volume constraints (DLVCs) were derived based on the P value map with a manual selection procedure facilitated by Spearman's correlation tests. The obtained DLVCs were further cross-validated using a multivariate support vector machine (SVM)-based normal tissue complication probability (NTCP) model with an independent testing data set composed of 8 adverse event and 13 control patients. RESULTS We extracted 2 DLVC constraints. One DLVC was obtained, Vdose/LETboundary:2.5keVμmat 75 Gy to 3.2keVμmat8.65Gy <1.27% (DLVC1), revealing a high LET volume effect. The second DLVC, V(72.2Gy,0keVμm) < 2.23% (DVLC2), revealed a high dose volume effect. The SVM-based NTCP model with 2 DLVCs provided slightly superior performance than using dose only, with an area under the curve of 0.798 versus 0.779 for the testing data set. CONCLUSIONS Our results demonstrated the importance of rectal "hot spots" in both high LET (DLVC1) and high dose (DLVC2) in inducing rectal bleeding. The SVM-based NTCP model confirmed the derived DLVCs as good predictors for rectal bleeding when intensity modulated proton therapy is used to treat prostate cancer.
Collapse
Affiliation(s)
- Yunze Yang
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Carlos E Vargas
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Ronik S Bhangoo
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - William W Wong
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Steven E Schild
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Thomas B Daniels
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Sameer R Keole
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | | | - Jennifer L Glass
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Jiajian Shen
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Todd A DeWees
- Division of Biostatics, Mayo Clinic Arizona, Phoenix, Arizona
| | - Tianming Liu
- Department of Computer Science, the University of Georgia, Athens, Georgia
| | - Martin Bues
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Mirek Fatyga
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Wei Liu
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona.
| |
Collapse
|
25
|
Singh G, Tyagi A, Thaper D, Kamal R, Kumar V, Oinam AS, Srivastava R, Halder S, Hukku S. Dosimetric analysis of cervical cancer stage IIB patients treated with volumetric modulated arc therapy using plan uncertainty parameters module of Varian Eclipse treatment planning system. Biomed Phys Eng Express 2021; 7. [PMID: 33862601 DOI: 10.1088/2057-1976/abf90a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 04/16/2021] [Indexed: 11/11/2022]
Abstract
Introduction. The present study aims to investigate the dosimetric and radiobiological impact of patient setup errors (PSE) on the target and organs at risk (OAR) of the cervix carcinoma stage IIB patients treated with volumetric-modulated arc therapy (VMAT) delivery technique using plan uncertainty parameters module of Varian Eclipse treatment planning system and in-house developed DVH Analyzer program.Materials and Methods. A total of 976 VMAT plans were generated to simulate the PSE in the base plan that varies from -10 mm to 10 mm in a step size of 1 mm in x- (lateral), y- (craniocaudal), and z- (anteroposterior) directions. The different OAR and tumor (PTV) volumes were delineated in each case. Various plan quality metrics, such as conformity index (CI) and homogeneity index (HI), as well as radiobiological quantities, such as tumor control probability (TCP) and normal tissue control probability (NTCP), were calculated from the DVH bands generated from the cohort of treatment plans associated with each patient case, using an in-house developed 'DVH Analyzer' program. The extracted parameters were statistically analyzed and compared with the base plan's dosimetric parameters having no PSE.Results. The maximum variation of (i) 2.4%, 21.5%, 0.8%, 2.5% in D2ccof bladder, rectum, small bowel and sigmoid colon respectively; (ii) 19.3% and 18.9% in Dmaxof the left and right femoral heads (iii) 16.9% in D95%of PTV (iv) 12.1% in NTCP of sigmoid colon were observed with change of PSE in all directions. TCP was found to be considerably affected for PSEs larger than 4 mm in x+, y+, z+directions and 7 mm in x-, y-and z-directions, respectively.Conclusion. This study presents the effect of PSE on TCP and NTCP for the cervix carcinoma cases treated with VMAT technique and also recommends daily image guidance to mitigate the effects of PSE.
Collapse
Affiliation(s)
- Gaganpreet Singh
- Centre for Medical Physics, Panjab University, Chandigarh, India.,Department of Radiotherapy, PGIMER, Chandigarh, India
| | - Atul Tyagi
- Department of Radiation Oncology, Dr B L Kapur Memorial Hospital, Delhi, India
| | - Deepak Thaper
- Centre for Medical Physics, Panjab University, Chandigarh, India.,Department of Radiotherapy, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Rose Kamal
- Centre for Medical Physics, Panjab University, Chandigarh, India.,Department of Radiotherapy, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Vivek Kumar
- Centre for Medical Physics, Panjab University, Chandigarh, India
| | - Arun S Oinam
- Department of Radiotherapy, PGIMER, Chandigarh, India
| | - Ranjana Srivastava
- Department of Radiation Oncology, Dr B L Kapur Memorial Hospital, Delhi, India
| | - Shikha Halder
- Department of Radiation Oncology, Dr B L Kapur Memorial Hospital, Delhi, India
| | - Shelly Hukku
- Department of Radiation Oncology, Dr B L Kapur Memorial Hospital, Delhi, India
| |
Collapse
|
26
|
Bryant CM, Henderson RH, Nichols RC, Mendenhall WM, Hoppe BS, Vargas CE, Daniels TB, Choo CR, Parikh RR, Giap H, Slater JD, Vapiwala N, Barrett W, Nanda A, Mishra MV, Choi S, Liao JJ, Mendenhall NP. Consensus Statement on Proton Therapy for Prostate Cancer. Int J Part Ther 2021; 8:1-16. [PMID: 34722807 PMCID: PMC8489490 DOI: 10.14338/ijpt-20-00031.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 02/02/2021] [Indexed: 11/21/2022] Open
Abstract
Proton therapy is a promising but controversial treatment in the management of prostate cancer. Despite its dosimetric advantages when compared with photon radiation therapy, its increased cost to patients and insurers has raised questions regarding its value. Multiple prospective and retrospective studies have been published documenting the efficacy and safety of proton therapy for patients with localized prostate cancer and for patients requiring adjuvant or salvage pelvic radiation after surgery. The Particle Therapy Co-Operative Group (PTCOG) Genitourinary Subcommittee intends to address current proton therapy indications, advantages, disadvantages, and cost effectiveness. We will also discuss the current landscape of clinical trials. This consensus report can be used to guide clinical practice and research directions.
Collapse
Affiliation(s)
- Curtis M. Bryant
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - Randal H. Henderson
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - R. Charles Nichols
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - William M. Mendenhall
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - Bradford S. Hoppe
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, USA
| | | | | | - C. Richard Choo
- Department of Radiation Oncology, Mayo Clinic Rochester, Rochester, MN, USA
| | - Rahul R. Parikh
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, NJ, USA
| | - Huan Giap
- Department of Radiation Oncology, University of Miami Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Jerry D. Slater
- Department of Radiation Oncology, Loma Linda University, Loma Linda, CA, USA
| | - Neha Vapiwala
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - William Barrett
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, OH, USA
| | - Akash Nanda
- Department of Radiation Oncology, Orlando Health, Orlando, FL, USA
| | - Mark V. Mishra
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Seungtaek Choi
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, TX, USA
| | - Jay J. Liao
- Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA, USA
| | - Nancy P. Mendenhall
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | | |
Collapse
|
27
|
Wang C, Wu L, Li W, Fei J, Xu J, Chen S, Yan S, Wang X. An injectable double-crosslinking iodinated composite hydrogel as a potential radioprotective spacer with durable imaging function. J Mater Chem B 2021; 9:3346-3356. [PMID: 33881426 DOI: 10.1039/d0tb02953j] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Prostate cancer is one of the leading causes of cancer incidence among males worldwide. Radiotherapy can achieve similar oncological outcomes to those of radical prostatectomy. One concern is, however, radiation damage to the rectum because of the extreme proximity between the two organs. Inserting a biomaterial to separate the prostate and rectum is a promising strategy, and an injectable hydrogel is regarded to be the preferred spacer after screening of various materials. Nevertheless, there exist shortcomings for the currently available injectable hydrogel that cannot fully meet the unique requirements in clinical practice. In this work, a novel injectable hydrogel spacer based on carboxymethyl chitosan (CMC), aldehyde guar gum (AG), and aldehyde iohexol (DHQ) with an imaging function is fabricated. Contrast agent DHQ is chemically attached to CMC-AG network to form a double-crosslinking network to obtain a controlled degradation rate and high strength as well as durable CT imaging function. The hydrogel is injected subcutaneously into rats, where rapid gelation occurs and it serves as a hydrogel spacer. During the month-long in vivo studies, the spacer exhibits remarkable radiation dose attenuation and sustainable imaging function, as well as excellent toxicity profiles. This novel hydrogel shows excellent potential in the protection of critical organs during prostate cancer radiotherapy.
Collapse
Affiliation(s)
- Cheng Wang
- College of Materials Science & Engineering, Zhejiang University of Technology, China.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Araujo IK, Muñoz-Guglielmetti D, Mollà M. Radiation-induced damage in the lower gastrointestinal tract: Clinical presentation, diagnostic tests and treatment options. Best Pract Res Clin Gastroenterol 2020; 48-49:101707. [PMID: 33317789 DOI: 10.1016/j.bpg.2020.101707] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 10/15/2020] [Accepted: 11/05/2020] [Indexed: 01/31/2023]
Abstract
Radiation therapy is an important ally when treating malignant lesions in the pelvic area, but it is not exempt of adverse events. There are some measures that can be taken to reduce the possibility of these effects, but some are non-modifiable factors related to previous treatments, location of the lesions or comorbidities. There is a wide variety of clinical presentations that can be of an acute or chronic onset that go from mild to severe forms or that can have a great impact in the quality of life. Medical available therapies as metronidazole, sucralfate, mesalizine or probiotics, can be of aid although some lack of solid evidence of efficacy. Endoscopic treatment can be performed with argon plasma coagulation, bipolar cautery, radiofrequency, laser therapy or dilation. Hyperbaric therapy can be applied in refractory cases and surgery must be reserved to selected patients due to its high morbidity and mortality.
Collapse
Affiliation(s)
- Isis K Araujo
- Endoscopy and Motility Unit, Gastroenterology Department, Hospital Clínic de Barcelona, Barcelona, Spain.
| | | | - Meritxell Mollà
- Radiation Oncology Department, Hospital Clínic de Barcelona, Barcelona, Spain.
| |
Collapse
|
29
|
Radiation Dose to the Rectum With Definitive Radiation Therapy and Hydrogel Spacer Versus Postprostatectomy Radiation Therapy. Adv Radiat Oncol 2020; 5:1225-1231. [PMID: 33305083 PMCID: PMC7718530 DOI: 10.1016/j.adro.2020.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Revised: 07/15/2020] [Accepted: 08/25/2020] [Indexed: 11/22/2022] Open
|
30
|
Glide-Hurst CK, Lee P, Yock AD, Olsen JR, Cao M, Siddiqui F, Parker W, Doemer A, Rong Y, Kishan AU, Benedict SH, Li XA, Erickson BA, Sohn JW, Xiao Y, Wuthrick E. Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology. Int J Radiat Oncol Biol Phys 2020; 109:1054-1075. [PMID: 33470210 DOI: 10.1016/j.ijrobp.2020.10.021] [Citation(s) in RCA: 141] [Impact Index Per Article: 28.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 10/08/2020] [Accepted: 10/19/2020] [Indexed: 12/21/2022]
Abstract
The integration of adaptive radiation therapy (ART), or modifying the treatment plan during the treatment course, is becoming more widely available in clinical practice. ART offers strong potential for minimizing treatment-related toxicity while escalating or de-escalating target doses based on the dose to organs at risk. Yet, ART workflows add complexity into the radiation therapy planning and delivery process that may introduce additional uncertainties. This work sought to review presently available ART workflows and technological considerations such as image quality, deformable image registration, and dose accumulation. Quality assurance considerations for ART components and minimum recommendations are described. Personnel and workflow efficiency recommendations are provided, as is a summary of currently available clinical evidence supporting the implementation of ART. Finally, to guide future clinical trial protocols, an example ART physician directive and a physics template following standard NRG Oncology protocol is provided.
Collapse
Affiliation(s)
- Carri K Glide-Hurst
- Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin.
| | - Percy Lee
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Adam D Yock
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jeffrey R Olsen
- Department of Radiation Oncology, University of Colorado- Denver, Denver, Colorado
| | - Minsong Cao
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Farzan Siddiqui
- Department of Radiation Oncology, Henry Ford Cancer Institute, Detroit, Michigan
| | - William Parker
- Department of Radiation Oncology, McGill University, Montreal, Quebec, Canada
| | - Anthony Doemer
- Department of Radiation Oncology, Henry Ford Cancer Institute, Detroit, Michigan
| | - Yi Rong
- Department of Radiation Oncology, University of California-Davis, Sacramento, California
| | - Amar U Kishan
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Stanley H Benedict
- Department of Radiation Oncology, University of California-Davis, Sacramento, California
| | - X Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Beth A Erickson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Jason W Sohn
- Department of Radiation Oncology, Allegheny Health Network, Pittsburgh, Pennsylvania
| | - Ying Xiao
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Evan Wuthrick
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida
| |
Collapse
|
31
|
Takakusagi Y, Katoh H, Kano K, Anno W, Tsuchida K, Mizoguchi N, Serizawa I, Yoshida D, Kamada T. Preliminary result of carbon-ion radiotherapy using the spot scanning method for prostate cancer. Radiat Oncol 2020; 15:127. [PMID: 32460889 PMCID: PMC7254700 DOI: 10.1186/s13014-020-01575-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 05/18/2020] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Carbon-ion radiotherapy (CIRT) for prostate cancer was initiated at Kanagawa Cancer Center in 2015. The present study analyzed the preliminary clinical outcomes of CIRT for prostate cancer. METHODS The clinical outcomes of 253 patients with prostate cancer who were treated with CIRT delivered using the spot scanning method between December 2015 and December 2017 were retrospectively analyzed. The irradiation dose was set at 51.6 Gy (relative biological effectiveness) delivered in 12 fractions over 3 weeks. Biochemical relapse was defined using the Phoenix definition. Toxicities were assessed according to CTCAE version 4.0. RESULTS The median patient age was 70 (47-86) years. The median follow-up duration was 35.3 (4.1-52.9) months. According to the D'Amico classification system, 8, 88, and 157 patients were classified as having low, intermediate, and high risks, respectively. Androgen deprivation therapy was administered in 244 patients. The biochemical relapse-free rate in the low-, intermediate-, and high-risk groups at 3 years was 87.5, 88.0, and 97.5%, respectively (P = 0.036). Grade 2 acute urinary toxicity was observed in 12 (4.7%) patients. Grade 2 acute rectal toxicity was not observed. Grade 2 late urinary toxicity and grade 2 late rectal toxicity were observed in 17 (6.7%) and 3 patients (1.2%), respectively. Previous transurethral resection of the prostate was significantly associated with late grade 2 toxicity in univariate analysis. The predictive factor for late rectal toxicity was not detected. CONCLUSION The present study demonstrated that CIRT using the spot scanning method for prostate cancer produces favorable outcomes.
Collapse
Affiliation(s)
- Yosuke Takakusagi
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Hiroyuki Katoh
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan.
| | - Kio Kano
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Wataru Anno
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Keisuke Tsuchida
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Nobutaka Mizoguchi
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Itsuko Serizawa
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Daisaku Yoshida
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| | - Tadashi Kamada
- Department of Radiation Oncology, Kanagawa Cancer Center, Asahi-ku, Yokohama, Kanagawa, 241-8515, Japan
| |
Collapse
|
32
|
Sahebnasagh A, Ghasemi A, Akbari J, Alipour A, Lashkardoost H, Ala S, Hosseinimehr SJ, Salehifar E. Prevention of acute radiation-induced Proctitis by Aloe vera: a prospective randomized, double-blind, placebo controlled clinical trial in Pelvic Cancer patients. BMC Complement Med Ther 2020; 20:146. [PMID: 32404169 PMCID: PMC7222341 DOI: 10.1186/s12906-020-02935-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 04/22/2020] [Indexed: 01/28/2023] Open
Abstract
Background Acute radiation-induced proctitis (ARP) is the most common side effect following radiotherapy for malignant pelvic disease. This study evaluated the efficacy of Aloe vera ointment in prevention of ARP. Methods Forty-two patients receiving external-beam radiotherapy (RT) for pelvic malignancies were randomized to receive either Aloe vera 3% or placebo topical ointment during radiotherapy for 6 weeks. These patients were evaluated based on the severity (grade 0–4) of the following symptoms weekly: rectal bleeding, abdominal/rectal pain, diarrhea, or fecal urgency. RTOG acute toxicity criteria and psychosocial status of the patients were also recorded weekly. Lifestyle impact of the symptoms, and quantitative measurement of C-reactive protein (CRP), an indicator of systemic inflammation, were also measured. Results The results of present study demonstrated a significant preventive effect for Aloe vera in occurrence of symptom index for diarrhea (p < 0.001), rectal bleeding (p < 0.001), and fecal urgency (p = 0.001). The median lifestyle score improved significantly with Aloe vera during RT (p < 0.001). Intervention patients had a significant lower burden of systemic inflammation as the values for quantitative CRP decreased significantly over 6 weeks of follow-up (p = 0.009). Conclusion This study showed that Aloe vera topical ointment was effective in prevention of symptoms of ARP in patients undergoing RT for pelvic cancers. Trial registration IRCT201606042027N6. Registration date: 2016-09-04.
Collapse
Affiliation(s)
- Adeleh Sahebnasagh
- Clinical Research Center, Department of Internal Medicine, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
| | - Arash Ghasemi
- Emam Khomeini Hospital, Mazandaran University of Medical Sciences, Sari, Iran
| | - Jafar Akbari
- Pharmaceutical Research Center, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Abbas Alipour
- Epidemiology, Faculty of Medicine, Community medicine Department, Mazandaran University of Medical Sciences, Sari, Iran
| | - Hossein Lashkardoost
- School of Public Health, North Khorasan University of Medical Sciences, Bojnurd, I.R, Iran
| | - Shahram Ala
- Pharmaceutical Research Center, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Seyed Jalal Hosseinimehr
- Department of Radiopharmacy, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Ebrahim Salehifar
- Gastrointestinal Cancer Research Center, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran. .,Department of Clinical Pharmacy, Faculty of Pharmacy, Mazandaran University of Medical Sciences, 48471-16548, Km 18 Khazarabad Road, Khazar sq., Sari, Mazandaran Province, Iran.
| |
Collapse
|
33
|
Zheng Y, Gao W, Spratt DE, Sun Y, Xing L. Management of gastrointestinal perforation related to radiation. Int J Clin Oncol 2020; 25:1010-1015. [DOI: 10.1007/s10147-020-01662-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 03/12/2020] [Indexed: 12/15/2022]
|
34
|
Paetkau O, Gagne IM, Alexander A. SpaceOAR© hydrogel rectal dose reduction prediction model: a decision support tool. J Appl Clin Med Phys 2020; 21:15-25. [PMID: 32250042 PMCID: PMC7324696 DOI: 10.1002/acm2.12860] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 02/10/2020] [Accepted: 03/04/2020] [Indexed: 12/12/2022] Open
Abstract
Prostate cancer external beam radiation therapy can result in toxicity due to organ at risk (OAR) dose, potentially impairing quality of life. A polyethylene glycol-based spacer, SpaceOAR© hydrogel (SOH), implanted between prostate gland and rectum may significantly reduce dose received by the rectum and hence risk of rectal toxicity. SOH implant is not equally effective in all patients. Determining patients in which the implant will offer most benefit, in terms of rectal dose reduction, allows for effective management of SOH resources. Several factors have been shown to be correlated with reduction in rectal dose including distance between rectum and planning treatment volume (PTV), volume of rectum in the PTV, and change in rectum volume pre- to post-SOH. Several of these factors along with other pre-SOH CT metrics were able to predict reduction in rectal dose associated with SOH implant. Rectal V55Gy metric, was selected as the dose level of interest in the context of 60 Gy in 20 fraction treatment plans. Models were produced to predict change in RV55Gy and pre-SOH hydrogel RV55Gy. These models offered R-squared between 0.81 and 0.88 with statistical significance in each model. Applying an ω 1 = 3% lower limit of pre-SOH RV55 Gy and an ω 2 = 3.5% lower limit on change in RV55 Gy, retained 60% of patients experiencing the largest rectal dose reduction from the hydrogel. This may offer a clinically useful tool in deciding which patients should receive SOH implant given limited resources. Predictive models, nomograms, and a workflow diagram were produced for clinical management of SOH implant.
Collapse
Affiliation(s)
- Owen Paetkau
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada
| | - Isabelle M Gagne
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada.,Department of Medical Physics, BC Cancer - Victoria, Victoria, BC, Canada
| | - Abraham Alexander
- Department of Radiation Oncology, BC Cancer - Victoria, Victoria, BC, Canada.,Department of Surgery, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
35
|
Briens A, Castelli J, Barateau A, Jaksic N, Gnep K, Simon A, De Crevoisier R. Radiothérapie adaptative : stratégies et bénéfices selon les localisations tumorales. Cancer Radiother 2019; 23:592-608. [DOI: 10.1016/j.canrad.2019.07.135] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 07/16/2019] [Indexed: 12/14/2022]
|
36
|
Cekani E, López-Guerra JL, Barrientos R, Tavera P, Praena-Fernandez JM, Rivin Del Campo E, Azinovic I, Matute R. Late toxicity for prostate cancer patients treated with hypofractionated helical tomotherapy. Rep Pract Oncol Radiother 2019; 24:298-305. [PMID: 31192999 DOI: 10.1016/j.rpor.2019.04.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 01/17/2019] [Accepted: 04/20/2019] [Indexed: 01/06/2023] Open
Abstract
AIM The purpose of this study is to evaluate the long term tolerability of hypofractionated helical tomotherapy (HT) in localized prostate cancer patients. BACKGROUND Previous hypofractionated schedules with conventional RT were associated with excessive toxicity, likely due to inadequate sophistication of treatment delivery. There are few data about late toxicity after HT. MATERIALS AND METHODS We evaluated 38 patients with primary adenocarcinoma of the prostate. There were 9 (24%), 15 (39%), and 14 (37%) patients with high, intermediate, and low risk, respectively. Patients were treated with hypofractionated HT from May 2008 to February 2011. Hypofractionation regimens included: 68.04 Gy at 2.52 Gy/fraction (N = 25; 66%), 70 Gy at 2.5 Gy/fraction (N = 4; 11%) and 70.2 Gy at 2.6 Gy/fraction (N = 9; 23%). Late genitourinary (GU) and gastrointestinal (GI) toxicity was scored using the Radiation Therapy Oncology Group scoring system. RESULTS Median age at diagnosis was 70 years (range 49-80) and median follow-up, 5.8 years. Late grade 1, 2 and 3 GI toxicity were 13%, 24%, and 2.6%, respectively. Late grade 1, 2, 3 GU toxicity were 29%, 21%, and 8%, respectively. Sexual toxicity was evaluated in 19 patients to be grade 1, 2 in 11% and grade 3 in 16%. Multivariate analysis showed that patients with higher values of rectum V50 associated with late GI toxicity (P = 0.025). Patients with PSA ≤8 (P = 0.048) or comorbidities (P = 0.013) at diagnosis were associated with higher late GU toxicity. Additionally, PSA ≤8 also associated with moderate (grade ≥2) late GU toxicity in the multivariate analysis (P = 0.028). CONCLUSIONS Hypofractionated HT can be delivered safely with limited rates of moderate and severe late toxicity. The proportion of the rectum that receives a moderate and high dose, having comorbidities, and PSA at diagnosis seem to associate with long term toxicity.
Collapse
Affiliation(s)
- Elona Cekani
- Máster Internacional en Aplicaciones Tecnológicas Avanzadas en Oncología Radioterápica de la Universidad de Murcia, GenesisCare Fundación, Madrid, Spain
| | | | - Rodrigo Barrientos
- Máster Internacional en Aplicaciones Tecnológicas Avanzadas en Oncología Radioterápica de la Universidad de Murcia, GenesisCare Fundación, Madrid, Spain
| | - Patricia Tavera
- Department of Radiation Oncology, GenesisCare, Madrid, Spain
| | | | | | | | - Raul Matute
- Department of Radiation Oncology, University Hospital La Paz, Madrid, Spain
| |
Collapse
|
37
|
Paetkau O, Gagne IM, Pai HH, Lam J, Goulart J, Alexander A. Maximizing rectal dose sparing with hydrogel: A retrospective planning study. J Appl Clin Med Phys 2019; 20:91-98. [PMID: 30889318 PMCID: PMC6448161 DOI: 10.1002/acm2.12566] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 01/21/2019] [Accepted: 02/23/2019] [Indexed: 12/14/2022] Open
Abstract
External beam radiation therapy for prostate cancer can result in urinary, sexual, and rectal side effects, often impairing quality of life. A polyethylene glycol‐based product, SpaceOAR© hydrogel (SOH), implanted into the connective tissue between the prostate gland and rectum can significantly reduce the dose received by the rectum and hence risk of rectal toxicity. The optimal way to manage the hydrogel and rectal structures for plan optimization is therefore of interest. In 13 patients, computerized tomography (CT) scans were taken pre‐ and post‐SpaceOAR© implant. A prescription of 60 Gy in 20 fractions was planned on both scans. Six treatment plans were produced per anonymized dataset using either a structure of rectum plus the hydrogel, termed composite rectum wall (CRW), or rectal wall (RW) as an inverse optimization structure and intensity modulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT) as a treatment technique. Dose‐volume histogram metrics were compared between plans to determine which optimization structure and treatment technique offered the maximum rectal dose sparing. RW structures offered a statistically significant decrease in rectal dose over CRW structures, whereas the treatment technique (IMRT vs VMAT) did not significantly affect the rectal dose. There was improvement seen in bladder and penile bulb dose when VMAT was used as a treatment technique. Overall, treatment plans using the RW optimization structure offered the lowest rectal dose while VMAT treatment technique offered the lowest bladder and penile bulb dose.
Collapse
Affiliation(s)
- Owen Paetkau
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada
| | - Isabelle M Gagne
- Department of Physics and Astronomy, University of Victoria, Victoria, BC, Canada.,Department of Medical Physics, BC Cancer - Victoria, Victoria, BC, Canada
| | - Howard H Pai
- Department of Radiation Oncology, BC Cancer - Victoria, Victoria, BC, Canada.,Department of Surgery, University of British Columbia, Vancouver, BC, Canada
| | - Jacqueline Lam
- Department of Radiation Oncology, BC Cancer - Victoria, Victoria, BC, Canada.,Department of Surgery, University of British Columbia, Vancouver, BC, Canada
| | - Jennifer Goulart
- Department of Radiation Oncology, BC Cancer - Victoria, Victoria, BC, Canada.,Department of Surgery, University of British Columbia, Vancouver, BC, Canada
| | - Abraham Alexander
- Department of Radiation Oncology, BC Cancer - Victoria, Victoria, BC, Canada.,Department of Surgery, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
38
|
Rectal retractor application during image-guided dose-escalated prostate radiotherapy. Strahlenther Onkol 2019; 195:923-933. [PMID: 30824942 DOI: 10.1007/s00066-019-01445-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 02/08/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE To investigate efficacy of a rectal retractor (RR) on rectal dose during image-guided dose-escalated prostate three-dimensional conformal radiotherapy (3DCRT). PATIENTS AND METHODS In all, 21 patients with localized prostate cancer were treated with a RR for 3DCRT in 40 × 2 Gy. Patient underwent two scans for radiotherapy planning, without and with RR. RR was used for the first half of the treatment sessions. Two plans were created for each patient to compare the effect of RR on rectal doses. PTW-31014 Pinpoint chamber embedded within RR was used for in vivo dosimetry in 6 of 21 patients. The patient tolerance and acute rectal toxicity were surveyed during radiotherapy using Common Terminology Criteria for Adverse Events (CTCAE) v.4.0. RESULTS Patients tolerated the RR well during 20 fractions with mild degree of anal irritation. Using a RR significantly reduced the rectal wall (RW), anterior RW and posterior RW dose-volume parameters. The average RW Dmean was 29.4 and 43.0 Gy for plans with and without RR, respectively. The mean discrepancy between the measured dose and planned dose was -3.8% (±4.9%). Grade 1 diarrhea, rectal urgency and proctitis occurred in 4, 2 and 3 cases, respectively. There were no grade ≥2 acute rectal toxicities during the treatment. CONCLUSION Rectal retraction resulted in a significant reduction of rectal doses with a safe toxicity profile, which may reduce rectal toxicity. Dosimeter inserted into the RR providing a practical method for in vivo dosimetric verification. Further prospective clinical studies will be necessary to demonstrate the clinical advantage of RR.
Collapse
|
39
|
Lee J, Han HJ, Min BS, Hong SP, Shin SJ, Yoon HI, Park SJ, Koom WS. The role of endoscopic evaluation for radiation proctitis in patients receiving intermediate-dose postoperative radiotherapy for rectal cancer. Jpn J Clin Oncol 2018; 48:988-994. [PMID: 30239826 DOI: 10.1093/jjco/hyy126] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 09/08/2018] [Indexed: 11/13/2022] Open
Abstract
Objectives High-dose pelvic radiotherapy (RT) is known to be associated with chronic radiation proctitis (RP). However, the effects of intermediate radiation doses are unknown. We assessed the incidence of late clinical RP among patients with rectal cancer receiving intermediate-dose postoperative RT, as well as the role of early endoscopic abnormalities in predicting RP development. Methods We retrospectively reviewed 153 patients with rectal cancer who received postoperative RT at a median dose of 54 Gy between 2005 and 2009 and who underwent endoscopic examination within 12 months thereafter. Endoscopic RP was assessed using the Vienna rectoscopy score (VRS). Late clinical RP toxicity was evaluated, as was its correlation with endoscopic RP. Results All patients underwent an endoscopic examination at a median of 9 months after postoperative pelvic RT. Endoscopic RP was detected in 45 patients (29.4%); the predominant patterns were telangiectasia and congested mucosa. During the median 88-month follow-up period, 29 patients (19.0%) experienced late clinical RP; only 3 (2.0%) had Grade 3 or above. The VRS predicted the development of late clinical RP as well as its cumulative incidence (P < 0.001). Endoscopic evidence of telangiectasia was significantly associated with the development of late clinical RP (P < 0.001). Conclusions Early endoscopic findings using VRS are useful for predicting the possibility of late clinical RP, although the incidences of severe cases were low. Patients with endoscopic abnormalities should be followed closely owing to their susceptibility to clinical RP.
Collapse
Affiliation(s)
- Jeongshim Lee
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul.,Department of Radiation Oncology, Inha University Hospital, Incheon
| | - Hee Ji Han
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul
| | - Byung So Min
- Department of Surgery, Yonsei University College of Medicine
| | - Sung Pil Hong
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine
| | - Sang Joon Shin
- Division of Medical Oncology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hong In Yoon
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul
| | - Soo Jung Park
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine
| | - Woong Sub Koom
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul
| |
Collapse
|
40
|
Effect of accounting for interfractional CTV shape variations in PTV margins on prostate cancer radiation treatment plans. Phys Med 2018; 54:66-76. [DOI: 10.1016/j.ejmp.2018.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 09/01/2018] [Accepted: 09/20/2018] [Indexed: 11/18/2022] Open
|
41
|
The use of hydrogel spacer in men undergoing high-dose prostate cancer radiotherapy: results of a prospective phase 2 clinical trial. World J Urol 2018; 37:1111-1116. [PMID: 30251049 DOI: 10.1007/s00345-018-2502-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 09/19/2018] [Indexed: 10/28/2022] Open
Abstract
PURPOSE The purpose of this study was to determine whether the degree of prostate to rectal separation using a hydrogel spacer (HS) and its effect on decreasing rectal dose can be reproduced in the community setting. METHODS Thirty one patients with cT1-3aN0M0 prostate adenocarcinoma receiving radical radiotherapy to 78 Gy were recruited to the study. The primary endpoint was the proportion of patients achieving at least 25% reduction in volume of rectum receiving 70 Gy (rV70). Other endpoints included degree of prostate to rectum separation, HS insertion-related adverse events and the proportion of patients with grade 1 or worse acute or late gastrointestinal (GI) and genitourinary (GU) toxicity. RESULTS All patients had successful insertion of their HS with no peri-operative toxicity. The mean prostate-rectal separation achieved was 10.5 mm. Twenty nine (93.5%) patients achieved a reduction in rV70 of at least 25%. Acute grade 1 GI toxicity was reported in 3 patients. All symptoms had resolved by 3 months post RT. Late grade 1 GI toxicity was reported in one patient (3.2%) with bowel frequency occurring at 6 months and resolving by 12 months post RT. There was no grade 2 or 3 acute or late GI toxicity seen. CONCLUSION In conclusion, this study illustrates that the application and benefits of HS on reducing GI rectal dose endpoints and toxicities during prostate cancer RT can be reliably replicated in a community setting similar to centres participating in the randomised trial under high quality assurance trial monitoring.
Collapse
|
42
|
Initial toxicity, quality-of-life outcomes, and dosimetric impact in a randomized phase 3 trial of hypofractionated versus standard fractionated proton therapy for low-risk prostate cancer. Adv Radiat Oncol 2018; 3:322-330. [PMID: 30202801 PMCID: PMC6128091 DOI: 10.1016/j.adro.2018.02.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 02/09/2018] [Accepted: 02/13/2018] [Indexed: 11/23/2022] Open
Abstract
Purpose Randomized evidence for extreme hypofractionation in prostate cancer is lacking. We aimed to identify differences in toxicity and quality-of-life outcomes between standard fractionation and extreme hypofractionated radiation in a phase 3 randomized trial. Methods and materials We analyzed the results of the first 75 patients in our phase 3 trial, comparing 38 Gy relative biologic effectiveness (RBE) in 5 fractions (n = 46) versus 79.2 Gy RBE in 44 fractions (n = 29). Patients received proton radiation using fiducials and daily image guidance. We evaluated American Urological Association Symptom Index (AUASI), adverse events (AEs), and Expanded Prostate Index Composite (EPIC) domains. The primary endpoint of this interim analysis was the cumulative incidence of grade 2 (G2) or higher AEs. The randomized patient allocation scheme was a 2:1 ratio favoring the 38 Gy RBE arm. Results The median follow-up was 36 months; 30% of patients reached 48-month follow-up. AUASI scores differed <5 points (4.4 vs 8.6; P = .002) at 1 year, favoring the 79.2 Gy arm. Differences in AUASI were not significant at ≥18 months. EPIC urinary symptoms favored the 79.2 Gy arm at 1 year (92.3 vs 84.5; P = .009) and 18 months (92.3 vs 85.3; P = .03); bother scores were not significant at other time points. Cumulative ≥G2 genitourinary toxicity was similar between the 79.2 Gy and 38 Gy arms (34.5% vs 30.4%; P = .80). We found no differences in the EPIC domains of bowel symptoms, sexual symptoms, or bowel ≥G2 toxicities. Bladder V80 (79.2 Gy arm; P = .04) and V39 (38 Gy arm; P = .05) were predictive for cumulative G2 genitourinary AEs. Conclusions Low AE rates were seen in both study arms. Early temporary differences in genitourinary scores disappeared over time. Bladder constraints were associated with genitourinary AEs.
Collapse
|
43
|
Kotabe K, Nakayama H, Takashi A, Takahashi A, Tajima T, Kume H. Association between rectal bleeding and the absolute dose volume of the rectum following image-guided radiotherapy for patients with prostate cancer. Oncol Lett 2018; 16:2741-2749. [PMID: 30013669 DOI: 10.3892/ol.2018.8888] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Accepted: 04/20/2018] [Indexed: 01/02/2023] Open
Abstract
The association between rectal bleeding and the received dose relative to the volume of the rectum is well established in prostate cancer patients who have undergone radiotherapy. The relative volume of the rectum is affected by the rectal anatomical volume, which depends on the definition of rectal length. Compared with the relative rectal volume, the absolute volume of the rectum may be more associated with rectal bleeding. The present study investigated the absolute volume of the rectum that may be used to predict late rectal bleeding following intensity-modulated radiotherapy (IMRT) and image-guided radiotherapy (IGRT). The cases of 82 patients of prostate cancer, who underwent IMRT and IGRT, were retrospectively evaluated by evaluating dose volume histograms. The median patient age was 73.4 years (range, 51.3-85.9 years). The median total prescribed dose was 76 Gy given in 38 fractions. The absolute and relative dose volumes of the rectum were evaluated by multivariate analysis, and the optimal dose to prevent rectal bleeding was determined. The actuarial ≥grade 1 rectal bleeding rate at 4 years was 4.5% (95% confidence interval, 1.5-13.4%) with a median observation period of 45.3 months. The absolute rectal volume (ml) treated with 60 Gy was the only significant risk factor for rectal bleeding (P<0.05), but the relative rectal volume (%) was not identified as a significant factor by the multivariate analysis. When the rectal volume of 5 or 10 ml received 60 Gy (D5cc and D10cc), rectal bleeding was expected to occur in 3.3 and 7.3% of the patients, respectively. Rectal D5cc ≤60 Gy is recommended to prevent late ≥grade 1 rectal bleeding in IGRT.
Collapse
Affiliation(s)
- Kazuki Kotabe
- Department of Radiation Oncology, National Center for Global Health and Medicine, Tokyo 162-8655, Japan
| | - Hidetsugu Nakayama
- Department of Radiation Oncology, National Center for Global Health and Medicine, Tokyo 162-8655, Japan
| | - Aruga Takashi
- Department of Radiation Oncology, Funabashi Municipal Medical Center, Tokyo 162-8655, Japan
| | - Atsuko Takahashi
- Department of Urology, National Center for Global Health and Medicine, Tokyo 162-8655, Japan
| | - Tsuyoshi Tajima
- Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655, Japan
| | - Haruki Kume
- Department of Urology, National Center for Global Health and Medicine, Tokyo 162-8655, Japan
| |
Collapse
|
44
|
Abstract
Radiation therapy (RT) is a curative treatment modality for localized prostate cancer. Over the past two decades, advances in technology and imaging have considerably changed RT in prostate cancer treatment. Treatment has evolved from 2-dimensional (2D) planning using X-ray fields based on pelvic bony landmarks to 3-dimensional (3D) conformal RT (CRT) which uses computed tomography (CT) based planning. Despite improvements with 3D-CRT, dose distributions often remained suboptimal with portions of the rectum and bladder receiving unacceptably high doses. In more recent years, intensity-modulated radiation therapy (IMRT) has become the standard of care to deliver external beam RT. IMRT uses multiple radiation beams of different shapes and intensities delivered from a wide range of angles to ‘paint’ the radiation dose onto the tumor. IMRT allows for a higher dose of radiation to be delivered to the prostate while reducing dose to surrounding organs. Multiple clinical trials have demonstrated improved cancer outcomes with dose escalation, but toxicities using 3D-CRT and escalated doses have been problematic. IMRT is a method to deliver dose escalated RT with more conformal dose distributions than 3D-CRT and has been associated with improved toxicity profiles. IMRT also appears to be the safest method to deliver hypofractionated RT and pelvic lymph node radiation. The purpose of this review is to summarize the technical aspects of IMRT planning and delivery, and to review the literature supporting the use of IMRT for prostate cancer.
Collapse
Affiliation(s)
- Ben W Fischer-Valuck
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, USA
| | - Yuan James Rao
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, USA
| | - Jeff M Michalski
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, USA
| |
Collapse
|
45
|
Krol R, McColl GM, Hopman WPM, Smeenk RJ. Anal and rectal function after intensity-modulated prostate radiotherapy with endorectal balloon. Radiother Oncol 2018; 128:364-368. [PMID: 29716753 DOI: 10.1016/j.radonc.2018.03.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2017] [Revised: 03/27/2018] [Accepted: 03/29/2018] [Indexed: 01/02/2023]
Abstract
BACKGROUND AND PURPOSE Late anorectal toxicity influences quality of life after external beam radiotherapy (EBRT) for prostate cancer. A daily inserted endorectal balloon (ERB) during EBRT aims to reduce anorectal toxicity. Our goal is to objectify anorectal function over time after prostate intensity-modulated radiotherapy (IMRT) with ERB. MATERIAL AND METHODS Sixty men, irradiated with IMRT and an ERB, underwent barostat measurements and anorectal manometry prior to EBRT and 6 months, one year and 2 years after radiotherapy. Primary outcome measures were rectal distensibility and rectal sensibility in response to stepwise isobaric distensions and anal pressures. RESULTS Forty-eight men completed all measurements. EBRT reduced maximal rectal capacity 2 years after EBRT (250 ± 10 mL vs. 211 ± 10 mL; p < 0.001), area under the pressure-volume curve (2878 ± 270 mL mmHg vs. 2521 ± 305 mL mmHg; p = 0.043) and rectal compliance (NS). Sensory pressure thresholds for first sense and first urge (both p < 0.01) increased. Anal maximum pressure diminished after IMRT (p = 0.006). CONCLUSIONS Rectal capacity and sensory function are increasingly affected over time after radiotherapy. There is an indication that these reductions are affected less with IMRT + ERB compared to conventional radiation techniques.
Collapse
Affiliation(s)
- Robin Krol
- Department of Gastroenterology and Hepatology, Radboud University Medical Centre, Nijmegen, The Netherlands.
| | - Gill M McColl
- Department of Radiation Oncology, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Wim P M Hopman
- Department of Gastroenterology and Hepatology, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Robert J Smeenk
- Department of Radiation Oncology, Radboud University Medical Centre, Nijmegen, The Netherlands
| |
Collapse
|
46
|
Chao M, Ho H, Chan Y, Tan A, Pham T, Bolton D, Troy A, Temelcos C, Sengupta S, McMillan K, Cham CW, Liu M, Ding W, Subramanian B, Wasiak J, Lim Joon D, Spencer S, Lawrentschuk N. Prospective analysis of hydrogel spacer for patients with prostate cancer undergoing radiotherapy. BJU Int 2018. [PMID: 29520983 DOI: 10.1111/bju.14192] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To report on the dosimetric benefits and late toxicity outcomes after injection of hydrogel spacer (HS) between the prostate and rectum for patients treated with prostate radiotherapy (RT). PATIENTS AND METHODS In all, 76 patients with a clinical stage of T1-T3a prostate cancer underwent general anaesthesia for fiducial marker insertion plus injection of the HS into the perirectal space before intensity-modulated RT (IMRT) or volumetric-modulated arc RT (VMAT). HS safety, dosimetric benefits, and the immediate- to long-term effects of gastrointestinal (GI) toxicity were assessed. RESULTS There were no postoperative complications reported. The mean (range) prostate size was 66.0 (25.0-187.0) mm. Rectal dose volume parameters were observed and the volume of rectum receiving 70 Gy (rV70 ), 75 Gy (rV75 ) and 78 Gy (rV78 ) was 7.8%, 3.6% and 0.4%, respectively. In all, 21% of patients (16/76) developed acute Grade 1 GI toxicities, but all were resolved completely by 3 months after treatment; whilst, 3% of patients (2/76) developed late Grade 1 GI toxicities. No patients had acute or late Grade ≥2 GI toxicities. CONCLUSION Injection of HS resulted in a reduction of irradiated rectal dose volumes along with minimal GI toxicities, irrespective of prostate size.
Collapse
Affiliation(s)
- Michael Chao
- The Austin Hospital, Heidelberg, Vic., Australia.,Genesis Cancer Care Victoria, Ringwood East, Vic., Australia
| | - Huong Ho
- Genesis Cancer Care Victoria, Ringwood East, Vic., Australia
| | - Yee Chan
- The Austin Hospital, Heidelberg, Vic., Australia.,Ringwood Private Hospital, Ringwood East, Vic., Australia
| | - Alwin Tan
- The Bays Hospital, Mornington, Vic., Australia
| | - Trung Pham
- The Valley Private Hospital, Mulgrave, Vic., Australia
| | - Damien Bolton
- The Austin Hospital, Heidelberg, Vic., Australia.,Ringwood Private Hospital, Ringwood East, Vic., Australia
| | - Andrew Troy
- The Austin Hospital, Heidelberg, Vic., Australia
| | | | - Shomik Sengupta
- The Austin Hospital, Heidelberg, Vic., Australia.,Melbourne University; Eastern Health Clinical School, Monash University, Clayton, Vic., Australia
| | - Kevin McMillan
- Ringwood Private Hospital, Ringwood East, Vic., Australia
| | | | - Madalena Liu
- Ringwood Private Hospital, Ringwood East, Vic., Australia
| | - Wei Ding
- Genesis Cancer Care Victoria, Ringwood East, Vic., Australia
| | | | - Jason Wasiak
- The Austin Hospital, Heidelberg, Vic., Australia.,University of Melbourne, Melbourne, Vic., Australia
| | - Daryl Lim Joon
- The Austin Hospital, Heidelberg, Vic., Australia.,Genesis Cancer Care Victoria, Ringwood East, Vic., Australia
| | - Sandra Spencer
- Genesis Cancer Care Victoria, Ringwood East, Vic., Australia
| | | |
Collapse
|
47
|
Boldrini L, Placidi E, Dinapoli N, Azario L, Cellini F, Massaccesi M, Chiesa S, Gambacorta MA, Mattiucci GC, Piccari D, Teodoli S, De Spirito M, Valentini V. Hybrid Tri-Co-60 MRI radiotherapy for locally advanced rectal cancer: An in silico evaluation. Tech Innov Patient Support Radiat Oncol 2018; 6:5-10. [PMID: 32095572 PMCID: PMC7033778 DOI: 10.1016/j.tipsro.2018.02.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2017] [Revised: 02/26/2018] [Accepted: 02/26/2018] [Indexed: 12/25/2022] Open
Abstract
Tri-Co-60 MRI radiotherapy (RT) is feasible in locally advanced rectal cancer. Larger volumes of normal tissue receive low-moderate doses in Tri-Co-60 MRI RT. Further studies on functional imaging applications and LinacMRI approach are needed. Tri-Co-60 MRI might represent a safe irradiation technique for pelvic tumors.
Introduction Aim of this paper is to investigate the plan quality of a tri-Co-60 MRI-Hybrid system for intensity-modulated radiation therapy (IMRT) in patients affected by locally advanced rectal cancer (LARC) undergoing neo-adjuvant radiotherapy. Materials and methods Ten consecutive LARC patients were selected. Tri-Co-60 step and shoot IMRT plans were generated simulating the presence of the magnetic field (Bon) or not (Boff) with the dedicated treatment planning system (TPS). The total planned dose was 45 Gy in 25 fractions to the mesorectum and the pelvic nodes (planning target volume 2, PTV2) and 55 Gy to the tumor and correspondent mesorectum (PTV1) through simultaneous integrated boost (SIB). Tri-Co-60 IMRT plans were compared with Volumetric Modulated Arc Therapy (VMAT) and IMRT plans for Linear Accelerator (Linac). Results Bon and Boff tri-Co-60 IMRT plans showed no relevant differences. Mean values of PTV1 and PTV2 receiving at least 95% of the Dp (V95%) were higher than 95% in all treatment plans. All plans met the V105% constraint for the PTV1. Mean values of V105% for the PTV2 were 14.8, 5.0, and 7.3% respectively for tri-Co-60, VMAT and IMRT. Mean Wu’s HI values were similar in all plans (7.4–7.8%). All plans met the V45Gy constraint for small bowel, but mean V45Gy value was higher with tri-Co-60. Bladder irradiation was comparable and always lower than the chosen D max 65 Gy constraint. Mean values of V5Gy and V20Gy to the body and median skin doses were higher with tri-Co-60 plans. Discussion Treatment plans with Tri-Co-60 step and shoot IMRT met the dose-volume objectives in patients with LARC. Nevertheless, a larger volume of normal tissue received low-moderate doses when compared with Linac based VMAT and IMRT.
Collapse
Affiliation(s)
- Luca Boldrini
- Polo Scienze Oncologiche ed Ematologiche, Istituto di Radiologia, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Elisa Placidi
- Polo Scienze delle immagini, di laboratorio e infettivologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Nicola Dinapoli
- Polo Scienze Oncologiche ed Ematologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Luigi Azario
- Polo Scienze delle immagini, di laboratorio e infettivologiche, Istituto di Fisica, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Francesco Cellini
- Polo Scienze Oncologiche ed Ematologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Mariangela Massaccesi
- Polo Scienze Oncologiche ed Ematologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Silvia Chiesa
- Polo Scienze Oncologiche ed Ematologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Maria Antonietta Gambacorta
- Polo Scienze Oncologiche ed Ematologiche, Istituto di Radiologia, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Gian Carlo Mattiucci
- Polo Scienze Oncologiche ed Ematologiche, Istituto di Radiologia, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Danila Piccari
- Polo Scienze Oncologiche ed Ematologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Stefania Teodoli
- Polo Scienze delle immagini, di laboratorio e infettivologiche, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Marco De Spirito
- Polo Scienze delle immagini, di laboratorio e infettivologiche, Istituto di Fisica, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| | - Vincenzo Valentini
- Polo Scienze Oncologiche ed Ematologiche, Istituto di Radiologia, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario Agostino Gemelli, Largo Francesco Vito, 1 - 00168 Roma, Italy
| |
Collapse
|
48
|
Ballare A, Di Salvo M, Loi G, Ferrari G, Beldì D, Krengli M. Conformal Radiotherapy of Clinically Localized Prostate Cancer: Analysis of Rectal and Urinary Toxicity and Correlation with Dose-Volume Parameters. TUMORI JOURNAL 2018; 95:160-8. [DOI: 10.1177/030089160909500206] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Aims and background Rectal and urinary toxicities are the principal limiting factors in delivering a high target dose to patients affected by prostate cancer. The verification of such toxicity is an important step before starting a dose-escalation program. The present observational study reports on the acute and late rectal and urinary toxicity in relation with dose-volume parameters in 104 patients with localized prostate cancer treated with 3-dimensional conformal radiation therapy. Methods and study design One hundred and four patients with stage T1b-T3b prostate cancer were treated with three-dimensional conformal radiation therapy to a total dose of 74 Gy, 2 Gy per fraction. Rigid dose constraints were applied for rectum and bladder. Acute and late rectal and urinary toxicities were analyzed also in relation to dose-volume histograms. Biochemical relapse-free survival was defined according to the American Society of Therapeutic Radiation Oncology (ASTRO) criteria and to the RTOG-ASTRO Phoenix Consensus Conference Recommendations using the Kaplan-Meier method. Results No grade 3 toxicity was observed. Acute and late grade 2 toxicity rates were 5.8% and 9.0% for rectum and 12.5% and 2.0% for bladder, respectively. Rectal V70 influenced the occurrence of late grade 2 toxicity. A relationship between acute and late urinary toxicity was also found. After a median follow-up of 30 months (range, 20–50), the actuarial overall and biochemical relapse-free survival rates were 84% and 77%, respectively, with a significant difference between low-intermediate and high-risk patients. Conclusions Conformal radiotherapy to the dose of 74 Gy was administered with good compliance. The incidence of acute and late toxicity was relatively low in accord with our dose constraints. Rectal V70 proved to be a reliable prognosticator of late toxicity. Overall survival and biochemical relapse-free survival rates were more favorable for low and intermediate-risk and significantly less favorable for high-risk patients.
Collapse
Affiliation(s)
- Andrea Ballare
- Radiotherapy, University of Piemonte Orientale Amedeo Avogadro and Hospital Maggiore della Carità, Novara, Italy
| | - Maurizio Di Salvo
- Radiotherapy, University of Piemonte Orientale Amedeo Avogadro and Hospital Maggiore della Carità, Novara, Italy
| | - Gianfranco Loi
- Medical Physics, Hospital Maggiore della Carità, Novara, Italy
| | - Gianmarco Ferrari
- Radiotherapy, University of Piemonte Orientale Amedeo Avogadro and Hospital Maggiore della Carità, Novara, Italy
| | - Debora Beldì
- Radiotherapy, University of Piemonte Orientale Amedeo Avogadro and Hospital Maggiore della Carità, Novara, Italy
| | - Marco Krengli
- Radiotherapy, University of Piemonte Orientale Amedeo Avogadro and Hospital Maggiore della Carità, Novara, Italy
| |
Collapse
|
49
|
Padmanabhan R, Pinkawa M, Song DY. Hydrogel spacers in prostate radiotherapy: a promising approach to decrease rectal toxicity. Future Oncol 2017; 13:2697-2708. [DOI: 10.2217/fon-2017-0073] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
High-dose radiation is a well-established method of treatment for prostate cancer. The main limiting structure for dose escalation is the rectum. The risk of rectal toxicity is related to dose received by the rectum. Several strategies for reducing dose to rectum have been explored; these include endorectal balloons as well as injection of rectal spacers like hydrogels. They create greater distance between rectal wall and prostate to confer a dosimetric advantage to the rectum. Early clinical studies with hydrogels have shown favorable outcomes. A low incidence of major procedural adverse effects with hydrogel use has been reported and it is well tolerated by patients. Hydrogel holds promise in establishing itself as an adjunct to standard of care in prostate radiation.
Collapse
Affiliation(s)
- Ranjani Padmanabhan
- Department of Radiation Oncology, INOVA Health System Fairfax, 3300 Gallows Road, Falls Church, VA 22042, USA
| | - Michael Pinkawa
- Department of Radiation Oncology, RWTH Aachen University, Pauwelsstrasse 30, 52057 Aachen, Germany
| | - Daniel Y Song
- Johns Hopkins Medicine, Department of Radiation Oncology & Molecular Radiation Sciences, Johns Hopkins University, 401 N Broadway, Baltimore, MD 21231, USA
| |
Collapse
|
50
|
Goenka A, Newman NB, Fontanilla H, Cahlon O, Chon B, Tsai H, Hug E, Brown C, Vargas C, Parikh RR. Patient-reported Quality of Life After Proton Beam Therapy for Prostate Cancer: The Effect of Prostate Size. Clin Genitourin Cancer 2017; 15:704-710. [DOI: 10.1016/j.clgc.2017.03.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 03/10/2017] [Accepted: 03/10/2017] [Indexed: 12/21/2022]
|