1
|
Han H, Geng C, Deng X, Li J, Shu D, Tang X. A preliminary study of multispectral Cherenkov imaging and a Fricke-xylenol orange gel film (MCIFF) for online, absolute dose measurement. Med Phys 2024; 51:3734-3745. [PMID: 38224326 DOI: 10.1002/mp.16942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 12/17/2023] [Accepted: 01/03/2024] [Indexed: 01/16/2024] Open
Abstract
BACKGROUND Cherenkov luminescence imaging has shown potential for relative dose distribution and field verification in radiation therapy. However, to date, limited research utilizing Cherenkov luminescence for absolute dose calibration has been conducted owing to uncertainties arising from camera positioning and tissue surface optical properties. PURPOSE This paper introduces a novel approach to multispectral Cherenkov luminescence imaging combined with Fricke-xylenol orange gel (FXG) film, termed MCIFF, which can enable online full-field absolute dose measurement. By integrating these two approaches, MCIFF allows for calibration of the ratio between two spectral intensities with absorbed dose, thereby enabling absolute dose measurement. METHODS All experiments are conducted on a Varian Clinac 23EX, utilizing an electron multiplying charge-coupled device (EMCCD) camera and a two-way image splitter for simultaneous capture of two-spectral Cherenkov imaging. In the first part of this study, the absorbance curves of the prepared FXG film, which receives different doses, are measured using a fluorescence spectrophotometer to verify the correlation between absorbance and dose. In the second part, the FXG film is positioned directly under the radiation beam to corroborate the dose measurement capacity of MCIFF across various beams. In the third part, the feasibility of MCIFF is tested in actual radiotherapy settings via a humanoid model, demonstrating its versatility with various radiotherapy materials. RESULTS The results of this study indicate that the logarithmic ratios of spectral intensities at wavelengths of 550 ± 50 and 700 ± 100 nm accurately reflect variations in radiation dose (R2 > 0.96) across different radiation beams, particle energies, and dose rates. The slopes of the fitting lines remain consistent under varying beam conditions, with discrepancies of less than 8%. The optical profiles obtained using the MCIFF exhibit a satisfactory level of agreement with the measured results derived from the treatment planning system (TPS) and EBT3 films. Specifically, for photon beams, the lateral distances between the 80% and 20% isodose lines, referred to as the penumbra (P80-20) values, obtained through TPS, EBT3 films, and MCIFF, are determined as 0.537, 0.664, and 0.848 cm, respectively. Similarly, for electron beams, the P80-20 values obtained through TPS, EBT3 films, and MCIFF are found to be 0.432, 0.561, and 0.634 cm, respectively. Furthermore, imaging of the anthropomorphic phantom demonstrates the practical application of MCIFF in real radiotherapy environments. CONCLUSION By combining an FXG film with Cherenkov luminescence imaging, MCIFF can calibrate Cherenkov luminescence to absorbed dose, filling the gap in online 2D absolute dose measurement methods in clinical practice, and providing a new direction for the clinical application of optical imaging to radiation therapy.
Collapse
Affiliation(s)
- Haonan Han
- Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
| | - Changran Geng
- Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
- Key Laboratory of Nuclear Technology Application and Radiation Protection in Astronautic, Nanjing University of Aeronautics and Astronautics, Ministry of Industry and Information Technology, Nanjing, People's Republic of China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
| | - Xinping Deng
- Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
| | - Jun Li
- Radiotherapy Center, Subei People's Hospital of Jiangsu Province, Yangzhou, People's Republic of China
| | - Diyun Shu
- Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
| | - Xiaobin Tang
- Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
- Key Laboratory of Nuclear Technology Application and Radiation Protection in Astronautic, Nanjing University of Aeronautics and Astronautics, Ministry of Industry and Information Technology, Nanjing, People's Republic of China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China
| |
Collapse
|
2
|
Decker SM, Bruza P, Zhang R, Williams BB, Jarvis LA, Pogue BW, Gladstone DJ. Technical note: Visual, rapid, scintillation point dosimetry for in vivo MV photon beam radiotherapy treatments. Med Phys 2024. [PMID: 38598093 DOI: 10.1002/mp.17071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 03/07/2024] [Accepted: 03/26/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND While careful planning and pre-treatment checks are performed to ensure patient safety during external beam radiation therapy (EBRT), inevitable daily variations mean that in vivo dosimetry (IVD) is the only way to attain the true delivered dose. Several countries outside the US require daily IVD for quality assurance. However, elsewhere, the manual labor and time considerations of traditional in vivo dosimeters may be preventing frequent use of IVD in the clinic. PURPOSE This study expands upon previous research using plastic scintillator discs for optical dosimetry for electron therapy treatments. We present the characterization of scintillator discs for in vivo x-ray dosimetry and describe additional considerations due to geometric complexities. METHODS Plastic scintillator discs were coated with reflective white paint on all sides but the front surface. An anti-reflective, matte coating was applied to the transparent face to minimize specular reflection. A time-gated iCMOS camera imaged the discs under various irradiation conditions. In post-processing, background-subtracted images of the scintillators were fit with Gaussian-convolved ellipses to extract several parameters, including integral output, and observation angle. RESULTS Dose linearity and x-ray energy independence were observed, consistent with ideal characteristics for a dosimeter. Dose measurements exhibited less than 5% variation for incident beam angles between 0° and 75° at the anterior surface and 0-60∘ $^\circ $ at the posterior surface for exit beam dosimetry. Varying the angle between the disc surface and the camera lens did not impact the integral output for the same dose up to 55°. Past this point, up to 75°, there is a sharp falloff in response; however, a correction can be used based on the detected width of the disc. The reproducibility of the integral output for a single disc is 2%, and combined with variations from the gantry angle, we report the accuracy of the proposed scintillator disc dosimeters as ±5.4%. CONCLUSIONS Plastic scintillator discs have characteristics that are well-suited for in vivo optical dosimetry for x-ray radiotherapy treatments. Unlike typical point dosimeters, there is no inherent readout time delay, and an optical recording of the measurement is saved after treatment for future reference. While several factors influence the integral output for the same dose, they have been quantified here and may be corrected in post-processing.
Collapse
Affiliation(s)
- Savannah M Decker
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Rongxiao Zhang
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA
| | | | - Lesley A Jarvis
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA
- Dartmouth Cancer Center, Dartmouth Health, Lebanon, New Hampshire, USA
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA
- Dartmouth Cancer Center, Dartmouth Health, Lebanon, New Hampshire, USA
| |
Collapse
|
3
|
Yamaguchi S, Ieko Y, Ariga H, Yoshioka K. Electron beam detection in radiotherapy using a capacitor dosimeter equipped with a silicon photodiode. Med Biol Eng Comput 2023:10.1007/s11517-023-02870-7. [PMID: 37380785 DOI: 10.1007/s11517-023-02870-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 06/16/2023] [Indexed: 06/30/2023]
Abstract
In this study, a newly developed capacitor dosimeter was evaluated using electron beams commonly utilized in radiotherapy. The capacitor dosimeter comprised a silicon photodiode, 0.47-μF capacitor, and dedicated terminal (dock). Before electron beam irradiation, the dosimeter was charged using the dock. The doses were measured without using a cable by reducing the charging voltages using the currents from the photodiode during irradiation. A commercially available parallel-plane-type ionization chamber and solid-water phantom were used for dose calibration with an electron energy of 6 MeV. In addition, the depth doses were measured using a solid-water phantom at electron energies of 6, 9, and 12 MeV. The doses were proportional to the discharging voltages, and the maximum dose difference in the calibrated doses measured using a two-point calibration was approximately 5% in the range of 0.25-1.98 Gy. The depth dependencies at energies of 6, 9, and 12 MeV corresponded to those measured using the ionization chamber.
Collapse
Affiliation(s)
- Satoshi Yamaguchi
- Department of Radiology, School of Medicine, Iwate Medical University, 2-1-1, Idaidori, Yahaba, Iwate, 028-3695, Japan.
| | - Yoshiro Ieko
- Department of Radiation Oncology, Iwate Medical University Hospital, Iwate Medical University, 2-1-1, Idaidori, Yahaba, Iwate, 028-3695, Japan
| | - Hisanori Ariga
- Department of Radiation Oncology, Iwate Medical University Hospital, Iwate Medical University, 2-1-1, Idaidori, Yahaba, Iwate, 028-3695, Japan
| | - Kunihiro Yoshioka
- Department of Radiology, School of Medicine, Iwate Medical University, 2-1-1, Idaidori, Yahaba, Iwate, 028-3695, Japan
| |
Collapse
|
4
|
Cloutier E, Beaulieu L, Archambault L. On the use of polychromatic cameras for high spatial resolution spectral dose measurements. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac6b0e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 04/27/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. Approach. The scintillation and Cherenkov signals produced in a radioluminescent phantom are imaged by a polychromatic camera and isolated using the spectral formalism. To do so, five demosaicing algorithms are investigated from calibration to measurements: a clustering method and four interpolation algorithms. The resulting accuracy of scintillation and Cherenkov images is evaluated with measurements of the differences (mean ± standard deviation) between the obtained and expected signals from profiles drawn across a scintillation spot. Signal-to-noise ratio and signal-to-background ratio are further measured and compared in the resulting scintillation images. Finally, the resulting differences on the scintillation signal from a 0.2 × 0.2 cm2 region-of-interest (ROI) were reported. Main results. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively yielded differences of 3 ± 5%, 1 ± 3%, 1 ± 3%, 1 ± 2% and 2 ± 4% in the resulting scintillation images. For the Cherenkov images, all algorithms provided differences below 1%. All methods enabled measurements over the detectability (SBR > 2) and sensitivity (SNR > 5) thresholds with the bilinear algorithm providing the best SNR value. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively provided differences on the ROI analysis of 7 ± 5%, 3 ± 2%, 3 ± 2%, 4 ± 2%, 7 ± 3%. Significance. Radioluminescent signals can accurately be isolated using a single polychromatic camera. Moreover, demosaicing using a bilinear kernel provided the best results and enabled Cherenkov signal subtraction while preserving the full spatial resolution of the camera.
Collapse
|
5
|
Andreozzi JM, Brůža P, Cammin J, Alexander DA, Pogue BW, Green O, Gladstone DJ. Optical emission-based phantom to verify coincidence of radiotherapy and imaging isocenters on an MR-linac. J Appl Clin Med Phys 2021; 22:252-261. [PMID: 34409766 PMCID: PMC8425893 DOI: 10.1002/acm2.13377] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 05/03/2021] [Accepted: 07/09/2021] [Indexed: 11/15/2022] Open
Abstract
Purpose Demonstrate a novel phantom design using a remote camera imaging method capable of concurrently measuring the position of the x‐ray isocenter and the magnetic resonance imaging (MRI) isocenter on an MR‐linac. Methods A conical frustum with distinct geometric features was machined out of plastic. The phantom was submerged in a small water tank, and aligned using room lasers on a MRIdian MR‐linac (ViewRay Inc., Cleveland, OH). The phantom physical isocenter was visualized in the MR images and related to the DICOM coordinate isocenter. To view the x‐ray isocenter, an intensified CMOS camera system (DoseOptics LLC., Hanover, NH) was placed at the foot of the treatment couch, and centered such that the optical axis of the camera was coincident with the central axis of the treatment bore. Two or four 8.3mm x 24.1cm beams irradiated the phantom from cardinal directions, producing an optical ring on the conical surface of the phantom. The diameter of the ring, measured at the peak intensity, was compared to the known diameter at the position of irradiation to determine the Z‐direction offset of the beam. A star‐shot method was employed on the front face of the frustum to determine X‐Y alignment of the MV beam. Known shifts were applied to the phantom to establish the sensitivity of the method. Results Couch translations, demonstrative of possible isocenter misalignments, on the order of 1mm were detectable for both the radiotherapy and MRI isocenters. Data acquired on the MR‐linac demonstrated an average error of 0.28mm(N=10, R2=0.997, σ=0.37mm) in established Z displacement, and 0.10mm(N=5, σ=0.34mm) in XY directions of the radiotherapy isocenter. Conclusions The phantom was capable of measuring both the MRI and radiotherapy treatment isocenters. This method has the potential to be of use in MR‐linac commissioning, and could be streamlined to be valuable in daily constancy checks of isocenter coincidence.
Collapse
Affiliation(s)
- Jacqueline M Andreozzi
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.,Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida, USA
| | - Petr Brůža
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Jochen Cammin
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Daniel A Alexander
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| | - Brian W Pogue
- Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire, USA
| | - Olga Green
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - David J Gladstone
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.,Geisel School of Medicine, Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA
| |
Collapse
|
6
|
Rahman M, Ashraf MR, Zhang R, Gladstone DJ, Cao X, Williams BB, Hoopes PJ, Pogue BW, Bruza P. Spatial and temporal dosimetry of individual electron FLASH beam pulses using radioluminescence imaging. Phys Med Biol 2021; 66:10.1088/1361-6560/ac0390. [PMID: 34015774 PMCID: PMC10468779 DOI: 10.1088/1361-6560/ac0390] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 05/20/2021] [Indexed: 11/11/2022]
Abstract
Purpose.In this study, spatio-temporal beam profiling for electron ultra-high dose rate (UHDR; >40 Gy s-1) radiation via Cherenkov emission and radioluminescence imaging was investigated using intensified complementary metal-oxide-semiconductor cameras.Methods.The cameras, gated to FLASH optimized linear accelerator pulses, imaged radioluminescence and Cherenkov emission incited by single pulses of a UHDR (>40 Gy s-1) 10 MeV electron beam delivered to the isocenter. Surface dosimetry was investigated via imaging Cherenkov emission or scintillation from a solid water phantom or Gd2O2S:Tb screen positioned on top of the phantom, respectively. Projected depth-dose profiles were imaged from a tank filled with water (Cherenkov emission) and a 1 g l-1quinine sulfate solution (scintillation). These optical results were compared with projected lateral dose profiles measured by Gafchromic film at different depths, including the surface.Results.The per-pulse beam output from Cherenkov imaging agreed with the photomultiplier tube Cherenkov output to within 3% after about the first five to seven ramp-up pulses. Cherenkov emission and scintillation were linear with dose (R2 = 0.987 and 0.995, respectively) and independent of dose rate from ∼50 to 300 Gy s-1(0.18-0.91 Gy/pulse). The surface dose distribution from film agreed better with scintillation than with Cherenkov emission imaging (3%/3 mm gamma pass rates of 98.9% and 88.8%, respectively). Using a 450 nm bandpass filter, the quinine sulfate-based water imaging of the projected depth optical profiles agreed with the projected film dose to within 5%.Conclusion.The agreement of surface dosimetry using scintillation screen imaging and Gafchromic film suggests it can verify the consistency of daily beam quality assurance parameters with an accuracy of around 2% or 2 mm. Cherenkov-based surface dosimetry was affected by the target's optical properties, prompting additional calibration. In projected depth-dose profiling, scintillation imaging via spectral suppression of Cherenkov emission provided the best match to film. Both camera-based imaging modalities resolved dose from single UHDR beam pulses of up to 60 Hz repetition rate and 1 mm spatial resolution.
Collapse
Affiliation(s)
- Mahbubur Rahman
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
| | - M. Ramish Ashraf
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
| | - Rongxiao Zhang
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
- Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College Hanover NH 03755 USA
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 USA
| | - David J. Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
- Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College Hanover NH 03755 USA
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 USA
| | - Xu Cao
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
| | - Benjamin B. Williams
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
- Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College Hanover NH 03755 USA
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 USA
| | - P. Jack Hoopes
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
- Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College Hanover NH 03755 USA
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 USA
- Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover NH 03755 USA
| | - Brian W. Pogue
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 USA
- Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover NH 03755 USA
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover NH 03755, US
| |
Collapse
|
7
|
Yukihara EG, Kron T. APPLICATIONS OF OPTICALLY STIMULATED LUMINESCENCE IN MEDICAL DOSIMETRY. RADIATION PROTECTION DOSIMETRY 2020; 192:122-138. [PMID: 33412585 DOI: 10.1093/rpd/ncaa213] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 11/15/2020] [Accepted: 11/23/2020] [Indexed: 06/12/2023]
Abstract
If the first decade of the new millennium saw the establishment of a more solid foundation for the use of the Optically Stimulated Luminescence (OSL) in medical dosimetry, the second decade saw the technique take root and become more widely used in clinical studies. Recent publications report not only characterization and feasibility studies of the OSL technique for various applications in radiotherapy and radiology, but also the practical use of OSL for postal audits, estimation of staff dose, in vivo dosimetry, dose verification and dose mapping studies. This review complements previous review papers and reports on the topic, providing a panorama of the new advances and applications in the last decade. Attention is also dedicated to potential future applications, such as LET dosimetry, 2D/3D dosimetry using OSL, dosimetry in magnetic resonance imaging-guided radiotherapy (MRIgRT) and dosimetry of extremely high dose rates (FLASH therapy).
Collapse
Affiliation(s)
- Eduardo G Yukihara
- Department of Radiation Safety and Security, Paul Scherrer Institute, 5200 Villigen, Switzerland
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, 3000 Melbourne, Australia
| |
Collapse
|
8
|
Alexander DA, Bruza P, Farwell JCM, Krishnaswamy V, Zhang R, Gladstone DJ, Pogue BW. Detective quantum efficiency of intensified CMOS cameras for Cherenkov imaging in radiotherapy. Phys Med Biol 2020; 65:225013. [PMID: 33179612 PMCID: PMC10416224 DOI: 10.1088/1361-6560/abb0c5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
In this study the metric of detective quantum efficiency (DQE) was applied to Cherenkov imaging systems for the first time, and results were compared for different detector hardware, gain levels and with imaging processing for noise suppression. Intensified complementary metal oxide semiconductor cameras using different image intensifier designs (Gen3 and Gen2+) were used to image Cherenkov emission from a tissue phantom in order to measure the modulation transfer function (MTF) and noise power spectrum (NPS) of the systems. These parameters were used to calculate the DQE for varying acquisition settings and image processing steps. MTF curves indicated that the Gen3 system had superior contrast transfer and spatial resolution than the Gen2+ system, with [Formula: see text] values of 0.52 mm-1 and 0.31 mm-1, respectively. With median filtering for noise suppression, these values decreased to 0.50 mm-1 and 0.26 mm-1. The maximum NPS values for the Gen3 and Gen2+ systems at high gain were 1.3 × 106 mm2 and 9.1 × 104 mm2 respectively, representing a 14x decrease in noise power for the Gen2+ system. Both systems exhibited increased NPS intensity with increasing gain, while median filtering lowered the NPS. The DQE of each system increased with increasing gain, and at the maximum gain levels the Gen3 system had a low-frequency DQE of 0.31%, while the Gen2+ system had a value of 1.44%. However, at a higher frequency of 0.4 mm-1, these values became 0.54% and 0.03%. Filtering improved DQE for the Gen3 system and reduced DQE for the Gen2+ system and had a mix of detrimental and beneficial qualitative effects by decreasing the spatial resolution and sharpness but also substantially lowering noise. This methodology for DQE measurement allowed for quantitative comparison between Cherenkov imaging cameras and improvements to their sensitivity, and yielded the first formal assessment of Cherenkov image formation efficiency.
Collapse
Affiliation(s)
- Daniel A Alexander
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
| | | | | | - Rongxiao Zhang
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
- Gesiel School of Medicine, Dartmouth College, Hanover, NH 03755, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, United States of America
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
- Gesiel School of Medicine, Dartmouth College, Hanover, NH 03755, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, United States of America
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
- DoseOptics LLC, Lebanon, NH 03766, United States of America
- Gesiel School of Medicine, Dartmouth College, Hanover, NH 03755, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, United States of America
| |
Collapse
|
9
|
Alexander DA, Zhang R, Brůža P, Pogue BW, Gladstone DJ. Scintillation imaging as a high‐resolution, remote, versatile 2D detection system for MR‐linac quality assurance. Med Phys 2020; 47:3861-3869. [PMID: 32583484 PMCID: PMC10363284 DOI: 10.1002/mp.14353] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/31/2020] [Accepted: 06/11/2020] [Indexed: 02/04/2023] Open
Abstract
PURPOSE To demonstrate the potential benefits of remote camera-based scintillation imaging for routine quality assurance (QA) measurements for magnetic resonance guided radiotherapy (MRgRT) linear accelerators. METHODS A wall-mounted CMOS camera with a time-synchronized intensifier was used to image photons produced from a scintillation screen in response to dose deposition from a 6 MV FFF x-ray beam produced by a 0.35 T MR-linac. The oblique angle of the field of view was corrected using a projective transform from a checkerboard calibration target. Output sensitivity and constancy was measured using the scintillator and benchmarked against an A28 ion chamber. Field cross-plane and in-plane profiles were measured for field sizes ranging from 1.68 × 1.66 cm2 to 20.02 × 19.92 cm2 with both scintillation imaging and using an IC profiler. Multileaf collimator (MLC) shifts were introduced to test sensitivity of the scintillation imaging system to small spatial deviations. A picket fence test and star-shot were delivered to both the scintillator and EBT3 film to compare accuracy in measuring MLC positions and isocenter size. RESULTS The scintillation imaging system showed comparable sensitivity and linearity to the ion chamber in response to changes in machine output down to 0.5 MU (R2 = 0.99). Cross-plane profiles show strong agreement with defined field sizes using full width half maximum (FWHM) measurement of <2 mm for field sizes below 15 cm, but the oblique viewing angle was the limiting factor in accuracy of in-plane profile widths. However, the system provided high-resolution profiles in both directions for constancy measurements. Small shifts in the field position down to 0.5 mm were detectable with <0.1 mm accuracy. Multileaf collimator positions as measured with both scintillation imaging and EBT3 film were measured within ± 1 mm tolerance and both detection systems produced similar isocenter sizes from the star-shot analysis (0.81 and 0.83 mm radii). CONCLUSIONS Remote scintillation imaging of a two-dimensional screen provided a rapid, versatile, MR-compatible solution to many routine quality assurance procedures including output constancy, profile flatness and symmetry constancy, MLC position verification and isocenter size. This method is high-resolution, does not require post-irradiation readout, and provides simple, instantaneous data acquisition. Full automation of the readout and processing could make this a very simple but effective QA tool, and is adaptable to all medical accelerators.
Collapse
Affiliation(s)
| | - Rongxiao Zhang
- Thayer School of Engineering and Geisel School of Medicine Dartmouth College Hanover NH03755USA
- Norris Cotton Cancer Center Dartmouth‐Hitchcock Medical Center Lebanon NH03756USA
| | - Petr Brůža
- Thayer School of Engineering Dartmouth College Hanover NH03755USA
| | - Brian W. Pogue
- Thayer School of Engineering and Geisel School of Medicine Dartmouth College Hanover NH03755USA
- Norris Cotton Cancer Center Dartmouth‐Hitchcock Medical Center Lebanon NH03756USA
| | - David J. Gladstone
- Thayer School of Engineering and Geisel School of Medicine Dartmouth College Hanover NH03755USA
- Norris Cotton Cancer Center Dartmouth‐Hitchcock Medical Center Lebanon NH03756USA
| |
Collapse
|
10
|
Tendler II, Bruza P, Jermyn M, Soter J, Sharp G, Williams B, Jarvis LA, Pogue B, Gladstone DJ. Technical Note: A novel dosimeter improves total skin electron therapy surface dosimetry workflow. J Appl Clin Med Phys 2020; 21:158-162. [PMID: 32306551 PMCID: PMC7324701 DOI: 10.1002/acm2.12880] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/11/2020] [Accepted: 03/13/2020] [Indexed: 01/15/2023] Open
Abstract
PURPOSE The novel scintillator-based system described in this study is capable of accurately and remotely measuring surface dose during Total Skin Electron Therapy (TSET); this dosimeter does not require post-exposure processing or annealing and has been shown to be re-usable, resistant to radiation damage, have minimal impact on surface dose, and reduce chances of operator error compared to existing technologies e.g. optically stimulated luminescence detector (OSLD). The purpose of this study was to quantitatively analyze the workflow required to measure surface dose using this new scintillator dosimeter and compare it to that of standard OSLDs. METHODS Disc-shaped scintillators were attached to a flat-faced phantom and a patient undergoing TSET. Light emission from these plastic discs was captured using a time-gated, intensified, camera during irradiation and converted to dose using an external calibration factor. Time required to complete each step (daily QA, dosimeter preparation, attachment, removal, registration, and readout) of the scintillator and OSLD surface dosimetry workflows was tracked. RESULTS In phantoms, scintillators and OSLDs surface doses agreed within 3% for all data points. During patient imaging it was found that surface dose measured by OSLD and scintillator agreed within 5% and 3% for 35/35 and 32/35 dosimetry sites, respectively. The end-to-end time required to measure surface dose during phantom experiments for a single dosimeter was 78 and 202 sec for scintillator and OSL dosimeters, respectively. During patient treatment, surface dose was assessed at 7 different body locations by scintillator and OSL dosimeters in 386 and 754 sec, respectively. CONCLUSION Scintillators have been shown to report dose nearly twice as fast as OSLDs with substantially less manual work and reduced chances of human error. Scintillator dose measurements are automatically saved to an electronic patient file and images contain a permanent record of the dose delivered during treatment.
Collapse
Affiliation(s)
| | - Petr Bruza
- Thayer School of EngineeringDartmouth CollegeHanoverNHUSA
| | - Michael Jermyn
- Thayer School of EngineeringDartmouth CollegeHanoverNHUSA
- DoseOptics LLCLebanonNHUSA
| | - Jennifer Soter
- Thayer School of EngineeringDartmouth CollegeHanoverNHUSA
| | - Gregory Sharp
- Department of Radiation OncologyMassachusetts General HospitalBostonMAUSA
| | - Benjamin Williams
- Department of MedicineGeisel School of MedicineDartmouth CollegeHanoverNHUSA
- Norris Cotton Cancer CenterDartmouth‐Hitchcock Medical CenterLebanonNHUSA
| | - Lesley A. Jarvis
- Department of MedicineGeisel School of MedicineDartmouth CollegeHanoverNHUSA
- Norris Cotton Cancer CenterDartmouth‐Hitchcock Medical CenterLebanonNHUSA
| | - Brian Pogue
- Thayer School of EngineeringDartmouth CollegeHanoverNHUSA
- DoseOptics LLCLebanonNHUSA
| | - David J. Gladstone
- Thayer School of EngineeringDartmouth CollegeHanoverNHUSA
- Department of MedicineGeisel School of MedicineDartmouth CollegeHanoverNHUSA
- Norris Cotton Cancer CenterDartmouth‐Hitchcock Medical CenterLebanonNHUSA
| |
Collapse
|
11
|
Andreozzi JM, Brůža P, Cammin J, Pogue BW, Gladstone DJ, Green O. Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR-linac. Med Phys 2020; 47:1258-1267. [PMID: 31821573 PMCID: PMC7112467 DOI: 10.1002/mp.13954] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 11/21/2019] [Accepted: 11/26/2019] [Indexed: 11/12/2022] Open
Abstract
PURPOSE Treatment planning systems (TPSs) for MR-linacs must employ Monte Carlo-based simulations of dose deposition to model the effects of the primary magnetic field on dose. However, the accuracy of these simulations, especially for areas of tissue-air interfaces where the electron return effect (ERE) is expected, is difficult to validate due to physical constraints and magnetic field compatibility of available detectors. This study employs a novel dosimetric method based on remotely captured, real-time optical Cherenkov and scintillation imaging to visualize and quantify the ERE. METHODS An intensified CMOS camera was used to image two phantoms with designed ERE cavities. Phantom A was a 40 cm × 10 cm × 10 cm clear acrylic block drilled with five holes of increasing diameters (0.5, 1, 2, 3, 4 cm). Phantom B was a clear acrylic block (25 cm × 20 cm × 5 cm) with three cavities of increasing diameter (3, 2, 1 cm) split into two halves in the transverse plane to accommodate radiochromic film. Both phantoms were imaged while being irradiated by 6 MV flattening filter free (FFF) beams within a MRIdian Viewray (Viewray, Cleveland, OH) MR-linac (0.34 T primary field). Phantom A was imaged while being irradiated by 6 MV FFF beams on a conventional linac (TrueBeam, Varian Medical Systems, San Jose, CA) to serve as a control. Images were post processed in Matlab (Mathworks Inc., Natick, MA) and compared to TPS dose volumes. RESULTS Control imaging of Phantom A without the presence of a magnetic field supports the validity of the optical image data to a depth of 6 cm. In the presence of the magnetic field, the optical data shows deviations from the commissioned TPS dose in both intensity and localization. The largest air cavity examined (3 cm) indicated the largest dose differences, which were above 20% at some locations. Experiments with Phantom B illustrated similar agreement between optical and film dosimetry comparisons with TPS data in areas not affected by ERE. CONCLUSION There are some appreciable differences in dose intensity and spatial dose distribution observed between the novel experimental data set and the dose models produced by the current clinically implemented MR-IGRT TPS.
Collapse
Affiliation(s)
- Jacqueline M. Andreozzi
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, USA
- Current: Department of Radiation Oncology, University of Florida, Gainesville, Florida 32608
| | - Petr Brůža
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, USA
| | - Jochen Cammin
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Brian W. Pogue
- Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755, USA
| | - David J. Gladstone
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03756, Geisel School of Medicine and Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, USA
| | - Olga Green
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| |
Collapse
|
12
|
Xie Y, Petroccia H, Maity A, Miao T, Zhu Y, Bruza P, Pogue BW, Plastaras JP, Dong L, Zhu TC. Cherenkov imaging for total skin electron therapy (TSET). Med Phys 2020; 47:201-212. [PMID: 31665544 PMCID: PMC7050296 DOI: 10.1002/mp.13881] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 10/16/2019] [Accepted: 10/16/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Total skin electron therapy (TSET) utilizes high-energy electrons to treat malignancies on the entire body surface. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interactions between the high-energy electron beam and tissue. METHODS AND MATERIALS With a time-gated intensified camera system, the Cherenkov emission can be used to evaluate the dose uniformity on the surface of the patient in real time. Fifteen patients undergoing TSET in various conditions (whole body and half body) were imaged and analyzed. Each patient was monitored during TSET via in vivo detectors (IVD) in nine locations. For accurate Cherenkov imaging, a comparison between IVD and Cherenkov profiles was conducted using a polyvinyl chloride board to establish the perspective corrections. RESULTS AND DISCUSSION With proper corrections developed in this study including the perspective and inverse square corrections, the Cherenkov imaging provided two-dimensional maps proportional to dose and projected on patient skin. The results of ratio between chest and umbilicus points were in good agreement with in vivo point dose measurements, with a standard deviation of 2.4% compared to OSLD measurements. CONCLUSIONS Cherenkov imaging is a viable tool for validating patient-specific dose distributions during TSET.
Collapse
Affiliation(s)
- Yunhe Xie
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Heather Petroccia
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Amit Maity
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Tianshun Miao
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
| | - Yihua Zhu
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
| | - Brian W. Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
- DoseOptics LLC, Lebanon, NH 03756, USA
| | - John P. Plastaras
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Timothy C. Zhu
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
13
|
Tendler II, Hartford A, Jermyn M, LaRochelle E, Cao X, Borza V, Alexander D, Bruza P, Hoopes J, Moodie K, Marr BP, Williams BB, Pogue BW, Gladstone DJ, Jarvis LA. Experimentally Observed Cherenkov Light Generation in the Eye During Radiation Therapy. Int J Radiat Oncol Biol Phys 2019; 106:422-429. [PMID: 31669563 DOI: 10.1016/j.ijrobp.2019.10.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 10/10/2019] [Accepted: 10/18/2019] [Indexed: 12/29/2022]
Abstract
PURPOSE Patients have reported sensations of seeing light flashes during radiation therapy, even with their eyes closed. These observations have been attributed to either direct excitation of retinal pigments or generation of Cherenkov light inside the eye. Both in vivo human and ex vivo animal eye imaging was used to confirm light intensity and spectra to determine its origin and overall observability. METHODS AND MATERIALS A time-gated and intensified camera was used to capture light exiting the eye of a patient undergoing stereotactic radiosurgery in real time, thereby verifying the detectability of light through the pupil. These data were compared with follow-up mechanistic imaging of ex vivo animal eyes with thin radiation beams to evaluate emission spectra and signal intensity variation with anatomic depth. Angular dependency of light emission from the eye was also measured. RESULTS Patient imaging showed that light generation in the eye during radiation therapy can be captured with a signal-to-noise ratio of 68. Irradiation of ex vivo eye samples confirmed that the spectrum matched that of Cherenkov emission and that signal intensity was largely homogeneous throughout the entire eye, from the cornea to the retina, with a slight maximum near 10 mm depth. Observation of the signal external to the eye was possible through the pupil from 0° to 90°, with a detected emission near 2500 photons per millisecond (during peak emission of the ON cycle of the pulsed delivery), which is over 2 orders of magnitude higher than the visible detection threshold. CONCLUSIONS By quantifying the spectra and magnitude of the signal, we now have direct experimental observations that Cherenkov light is generated in the eye during radiation therapy and can contribute to perceived light flashes. Furthermore, this technique can be used to further study and measure phosphenes in the radiation therapy clinic.
Collapse
Affiliation(s)
- Irwin I Tendler
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Alan Hartford
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire; Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | - Michael Jermyn
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire; DoseOptics LLC, Lebanon, New Hampshire
| | - Ethan LaRochelle
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Xu Cao
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Victor Borza
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Daniel Alexander
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Jack Hoopes
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire; Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire
| | - Karen Moodie
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | - Brian P Marr
- Department of Ophthalmic Oncology, Columbia University Medical Center, New York, New York
| | - Benjamin B Williams
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire; Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire; DoseOptics LLC, Lebanon, New Hampshire; Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire; Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire; Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | - Lesley A Jarvis
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire; Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire.
| |
Collapse
|
14
|
Alexander DA, Tendler II, Bruza P, Cao X, Schaner PE, Marshall BS, Jarvis LA, Gladstone DJ, Pogue BW. Assessment of imaging Cherenkov and scintillation signals in head and neck radiotherapy. Phys Med Biol 2019; 64:145021. [PMID: 31146269 DOI: 10.1088/1361-6560/ab25a3] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The goal of this study was to test the utility of time-gated optical imaging of head and neck (HN) radiotherapy treatments to measure surface dosimetry in real-time and inform possible interfraction replanning decisions. The benefit of both Cherenkov and scintillator imaging in HN treatments is direct daily feedback on dose, with no change to the clinical workflow. Emission from treatment materials was characterized by measuring radioluminescence spectra during irradiation and comparing emission intensities relative to Cherenkov emission produced in phantoms and scintillation from small plastic targets. HN treatment plans were delivered to a phantom with bolus and mask present to measure impact on signal quality. Interfraction superficial tumor reduction was simulated on a HN phantom, and cumulative Cherenkov images were analyzed in the region of interest (ROI). HN human patient treatment was imaged through the mask and compared with the dose distribution calculated by the treatment planning system. The relative intensity of radioluminescence from the mask was found to be within 30% of the Cherenkov emission intensity from tissue-colored clay. A strong linear relationship between normalized cumulative Cherenkov intensity and tumor size was established ([Formula: see text]). The presence of a mask above a scintillator ROI was found to decrease mean pixel intensity by >40% and increase distribution spread. Cherenkov imaging through mask material is shown to have potential for surface field verification and tracking of superficial anatomy changes between treatment fractions. Imaging of scintillating targets provides a direct imaging of surface dose on the patient and through transparent bolus material. The first imaging of a patient receiving HN radiotherapy was achieved with a signal map which qualitatively matches the surface dose plan.
Collapse
Affiliation(s)
- Daniel A Alexander
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Tendler II, Bruza P, Jermyn M, Fleury A, Williams BB, Jarvis LA, Pogue BW, Gladstone DJ. Improvements to an optical scintillator imaging-based tissue dosimetry system. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-6. [PMID: 31313537 PMCID: PMC6630097 DOI: 10.1117/1.jbo.24.7.075001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Accepted: 06/24/2019] [Indexed: 05/15/2023]
Abstract
Previous work has shown that capturing optical emission from plastic discs attached directly to the skin can be a viable means to accurately measure surface dose during total skin electron therapy. This method can provide accurate dosimetric information rapidly and remotely without the need for postprocessing. The objective of this study was to: (1) improve the robustness and usability of the scintillators and (2) enhance sensitivity of the optical imaging system to improve scintillator emission detection as related to tissue surface dose. Baseline measurements of scintillator optical output were obtained by attaching the plastic discs to a flat tissue phantom and simultaneously irradiating and imaging them. Impact on underlying surface dose was evaluated by placing the discs on-top of the active element of an ionization chamber. A protective coating and adhesive backing were added to allow easier logistical use, and they were also subjected to disinfection procedures, while verifying that these changes did not affect the linearity of response with dose. The camera was modified such that the peak of detector quantum efficiency better overlapped with the emission spectra of the scintillating discs. Patient imaging was carried out and surface dose measurements were captured by the updated camera and compared to those produced by optically stimulated luminescence detectors (OSLD). The updated camera was able to measure surface dose with < 3 % difference compared to OSLD–Cherenkov emission from the patient was suppressed and scintillation detection was enhanced by 25 × and 7 × , respectively. Improved scintillators increase underlying surface dose on average by 5.2 ± 0.1 % and light output decreased by 2.6 ± 0.3 % . Disinfection had < 0.02 % change on scintillator light output. The enhanced sensitivity of the imaging system to scintillator optical emission spectrum can now enable a reduction in physical dimensions of the dosimeters without loss in ability to detect light output.
Collapse
Affiliation(s)
- Irwin I. Tendler
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Address all correspondence to Irwin I. Tendler, E-mail:
| | - Petr Bruza
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Michael Jermyn
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- DoseOptics LLC, Lebanon, New Hampshire, United States
| | - Antoine Fleury
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Université de Strasbourg, Télécom Physique Strasbourg, Illkirch-Graffenstaden, France
| | - Benjamin B. Williams
- Dartmouth College, Geisel School of Medicine, Department of Medicine, Hanover, New Hampshire, United States
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, United States
| | - Lesley A. Jarvis
- Dartmouth College, Geisel School of Medicine, Department of Medicine, Hanover, New Hampshire, United States
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- DoseOptics LLC, Lebanon, New Hampshire, United States
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, United States
| | - David J. Gladstone
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Dartmouth College, Geisel School of Medicine, Department of Medicine, Hanover, New Hampshire, United States
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, United States
| |
Collapse
|
16
|
Tendler II, Bruza P, Jermyn M, Cao X, Williams BB, Jarvis LA, Pogue BW, Gladstone DJ. Characterization of a non-contact imaging scintillator-based dosimetry system for total skin electron therapy. Phys Med Biol 2019; 64:125025. [PMID: 31035267 PMCID: PMC10653344 DOI: 10.1088/1361-6560/ab1d8a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Surface dosimetry is required for ensuring effective administration of total skin electron therapy (TSET); however, its use is often reduced due to the time consuming and complex nature of acquisition. A new surface dose imaging technique was characterized in this study and found to provide accurate, rapid and remote measurement of surface doses without the need for post-exposure processing. Disc-shaped plastic scintillators (1 mm thick × 15 mm [Formula: see text]) were chosen as optimal-sized samples and designed to attach to a flat-faced phantom for irradiation using electron beams. Scintillator dosimeter response to radiation damage, dose rate, and temperature were studied. The effect of varying scintillator diameter and thickness on light output was evaluated. Furthermore, the scintillator emission spectra and impact of dosimeter thickness on surface dose were also quantified. Since the scintillators were custom-machined, dosimeter-to-dosimeter variation was tested. Scintillator surface dose measurements were compared to those obtained by optically stimulated luminescence dosimeters (OSLD). Light output from scintillator dosimeters evaluated in this study was insensitive to radiation damage, temperature, and dose rate. Maximum wavelength of emission was found to be 422 nm. Dose reported by scintillators was linearly related to that from OSLDs. Build-up from placement of scintillators and OSLDs had a similar effect on surface dose (4.9% increase). Variation among scintillator dosimeters was found to be 0.3 ± 0.2%. Scintillator light output increased linearly with dosimeter thickness (~1.9 × /mm). All dosimeter diameters tested were able to accurately measure surface dose. Scintillator dosimeters can potentially improve surface dosimetry-associated workflow for TSET in the radiation oncology clinic. Since scintillator data output can be automatically recorded to a patient medical record, the chances of human error in reading out and recording surface dose are minimized.
Collapse
Affiliation(s)
- Irwin I Tendler
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
| | - Mike Jermyn
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
- DoseOptics LLC, Lebanon, NH, United States of America
| | - Xu Cao
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
| | - Benjamin B Williams
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States of America
| | - Lesley A Jarvis
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States of America
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
- DoseOptics LLC, Lebanon, NH, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States of America
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States of America
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, United States of America
| |
Collapse
|
17
|
Tendler II, Bredfeldt JS, Zhang R, Bruza P, Jermyn M, Pogue BW, Gladstone DJ. Technical Note: Quality assurance and relative dosimetry testing of a 60 Co total body irradiator using optical imaging. Med Phys 2019; 46:3674-3678. [PMID: 31152565 DOI: 10.1002/mp.13637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 05/15/2019] [Accepted: 05/28/2019] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The aim of this study was to create an optical imaging-based system for quality assurance (QA) testing of a dedicated Co-60 total body irradiation (TBI) machine. Our goal is to streamline the QA process by minimizing the amount time necessary for tests such as verification of dose rate and field homogeneity. METHODS Plastic scintillating rods were placed directly on the patient treatment couch of a dedicated TBI 60 Co irradiator. A tripod-mounted intensified camera was placed directly adjacent to the couch. Images were acquired over a 30-s period once the cobalt source was fully exposed. Real-time image filtering was used; cumulative images were flatfield corrected as well as background and darkfield subtracted. Scintillators were used to measure light-radiation field correspondence, dose rate, field homogeneity, and symmetry. Dose rate effects were measured by modifying the height of the treatment couch and scintillator response was compared to ionization chamber (IC) measurements. Optically stimulated luminesce detector (OSLD) used as reference dosimeters during field symmetry and homogeneity testing. RESULTS The scintillator-based system accurately reported changes in dose rate. When comparing normalized output values for IC vs scintillators over a range of source-to-surface distances, a linear relationship (R2 = 0.99) was observed. Normalized scintillator signal matched OSLD measurements with <1.5% difference during field homogeneity and symmetry testing. Beam symmetry across both axes of the field was within 2%. The light field was found to correspond to 90 ± 3% of the isodose maximum along the longitudinal and latitudinal axis, respectively. Scintillator imaging output results using a single image stack requiring no postexposure processing (needed for OSLD) or repeat manual measurements (needed for IC). CONCLUSION Imaging of scintillation light emission from plastic rods is a viable and efficient method for carrying out TBI 60 Co irradiator QA. We have shown that this technique can accurately measure field homogeneity, symmetry, light-radiation field correspondence, and dose rate effects.
Collapse
Affiliation(s)
- Irwin I Tendler
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Jeremy S Bredfeldt
- Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Boston, MA, USA.,Harvard Medical School, Boston, MA, USA
| | - Rongxiao Zhang
- Winship Cancer Institute, Emory University, Atlanta, GA, USA
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.,DoseOptics LLC, Lebanon, NH, USA
| | - Michael Jermyn
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.,DoseOptics LLC, Lebanon, NH, USA
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.,DoseOptics LLC, Lebanon, NH, USA.,Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, USA
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.,Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH, USA.,Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, USA
| |
Collapse
|