1
|
Gupta A, Glein R, Hossain N, Sundhu M, Rotondo R, Sheldon SH, Noheria A. Safety of particle radiotherapy in patients with cardiac implantable electronic devices: Review of literature. Pacing Clin Electrophysiol 2024; 47:1556-1561. [PMID: 39119850 DOI: 10.1111/pace.15050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 06/14/2024] [Accepted: 07/18/2024] [Indexed: 08/10/2024]
Affiliation(s)
- Amulya Gupta
- Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Rachel Glein
- The University of Kansas School of Medicine, Kansas City, Kansas, USA
| | - Nabil Hossain
- The University of Kansas School of Medicine, Kansas City, Kansas, USA
| | - Murtaza Sundhu
- Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Ronny Rotondo
- Department of Radiation Oncology, The University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Seth H Sheldon
- Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Amit Noheria
- Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA
| |
Collapse
|
2
|
Zhang S, Hu L, Tang H, Liao L, Li X. Stereotactic arrhythmia radioablation (STAR) opens a new era in the treatment of arrhythmias? Front Cardiovasc Med 2024; 11:1449028. [PMID: 39399514 PMCID: PMC11469775 DOI: 10.3389/fcvm.2024.1449028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 09/10/2024] [Indexed: 10/15/2024] Open
Abstract
Tachyarrhythmias are common cardiovascular emergencies encountered in clinical practice. Among these, atrial fibrillation (AF) and ventricular tachycardia (VT) pose significant hazards due to their prevalence and severity. Initially, non-invasive pharmacological antiarrhythmic interventions were the primary treatment modality; however, due to their limited control rates and side effects, invasive therapies have been introduced in recent years. These include catheter ablation, alcohol ablation, cardiac implantable electronic devices, and heart transplantation. Nonetheless, for some patients, invasive treatments do not offer a definitive cure for arrhythmias and carry the risk of recurrence, especially with AF and VT, where the relapse rates are high and the treatment for VT is correlated with the type of tachycardia present. Currently, novel non-invasive treatment methods are emerging, with stereotactic radioablation therapy becoming an effective alternative for the management of refractory tachyarrhythmias. This review provides an overview of the application background of Stereotactic Arrhythmia Radioablation (STAR) therapy and promising results from its use in animal models and clinical applications.
Collapse
Affiliation(s)
| | | | | | | | - Xuping Li
- Department of Cardiovascular Medicine, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| |
Collapse
|
3
|
Kawakami Y, Sakai M, Masuda H, Miyajima M, Kanzaki T, Kobayashi K, Ohno T, Sakurai H. The Contribution of Secondary Particles Following Carbon Ion Radiotherapy to Soft Errors in CIEDs. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2024; 5:157-162. [PMID: 38487101 PMCID: PMC10939317 DOI: 10.1109/ojemb.2024.3358989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/17/2023] [Accepted: 01/16/2024] [Indexed: 03/17/2024] Open
Abstract
Introduction: While carbon ion radiotherapy is highly effective in cancer treatment, it has a high risk of causing soft error, which leads to malfunctions in cardiac implantable electrical devices (CIEDs). To predict the risk of malfunction prior to treatment, it is necessary to measure the reaction cross-sections and contributions to the soft error of secondary particles generated during treatments. Methods: A field-programmable gate array was used instead of CIEDs to measure soft errors by varying the energy spectrum of secondary particles. Results and discussion: The reaction cross-sections measured for each secondary particle were 3.0 × 10-9, 2.0 × 10-9, 1.3 × 10-8, and 1.5 × 10-8 [cm2/Mb] for thermal neutrons, intermediate-energy neutrons, high-energy neutrons above 10 MeV, and protons, respectively. The contribution of high-energy neutrons was the largest among them. Our study indicates that to reduce the risk of soft errors, secure distance and appropriate irradiation directions are necessary.
Collapse
Affiliation(s)
- Yudai Kawakami
- Graduate School of Science and Technology, Gunma UniversityKiryu376-8515Japan
| | - Makoto Sakai
- Gunma University Heavy Ion Medical CenterMaebashi371-8511Japan
| | | | | | | | - Kazutoshi Kobayashi
- Graduate School of Science and TechnologyKyoto Institute of TechnologyKyoto606-8585Japan
| | - Tatsuya Ohno
- Gunma University Heavy Ion Medical CenterMaebashi371-8511Japan
| | - Hiroshi Sakurai
- Graduate School of Science and Technology, Gunma UniversityKiryu376-8515Japan
| |
Collapse
|
4
|
Mirzaei M, Rowshanfarzad P, Gill S, Ebert MA, Dass J. Risk of cardiac implantable device malfunction in cancer patients receiving proton therapy: an overview. Front Oncol 2023; 13:1181450. [PMID: 37469405 PMCID: PMC10352826 DOI: 10.3389/fonc.2023.1181450] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 06/12/2023] [Indexed: 07/21/2023] Open
Abstract
Age is a risk factor for both cardiovascular disease and cancer, and as such radiation oncologists frequently see a number of patients with cardiac implantable electronic devices (CIEDs) receiving proton therapy (PT). CIED malfunctions induced by PT are nonnegligible and can occur in both passive scattering and pencil beam scanning modes. In the absence of an evidence-based protocol, the authors emphasise that this patient cohort should be managed differently to electron- and photon- external beam radiation therapy (EBRT) patients due to distinct properties of proton beams. Given the lack of a PT-specific guideline for managing this cohort and limited studies on this important topic; the process was initiated by evaluating all PT-related CIED malfunctions to provide a baseline for future reporting and research. In this review, different modes of PT and their interactions with a variety of CIEDs and pacing leads are discussed. Effects of PT on CIEDs were classified into a variety of hardware and software malfunctions. Apart from secondary neutrons, cumulative radiation dose, dose rate, CIED model/manufacturer, distance from CIED to proton field, and materials used in CIEDs/pacing leads were all evaluated to determine the probability of malfunctions. The importance of proton beam arrangements is highlighted in this study. Manufacturers should specify recommended dose limits for patients undergoing PT. The establishment of an international multidisciplinary team dedicated to CIED-bearing patients receiving PT may be beneficial.
Collapse
Affiliation(s)
- Milad Mirzaei
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- Department of Medical Imaging and Radiation Sciences, School of Biomedical Sciences, Monash University, Clayton, VIC, Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Suki Gill
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Martin A. Ebert
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Joshua Dass
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| |
Collapse
|
5
|
Stühlinger M, Burri H, Vernooy K, Garcia R, Lenarczyk R, Sultan A, Brunner M, Sabbag A, Özcan EE, Ramos JT, Di Stolfo G, Suleiman M, Tinhofer F, Aristizabal JM, Cakulev I, Eidelman G, Yeo WT, Lau DH, Mulpuru SK, Nielsen JC, Heinzel F, Prabhu M, Rinaldi CA, Sacher F, Guillen R, de Pooter J, Gandjbakhch E, Sheldon S, Prenner G, Mason PK, Fichtner S, Nitta T. EHRA consensus on prevention and management of interference due to medical procedures in patients with cardiac implantable electronic devices. Europace 2022; 24:1512-1537. [PMID: 36228183 DOI: 10.1093/europace/euac040] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023] Open
Affiliation(s)
- Markus Stühlinger
- Department of Internal Medicine III - Cardiology and Angiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Haran Burri
- Department of Cardiology, University Hospital of Geneva, Geneva, Switzerland
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Rodrigue Garcia
- Department of Cardiology, University Hospital of Poitiers, Poitiers, France
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Radoslaw Lenarczyk
- Department of Cardiology, Congenital Heart Disease and Electrotherapy, Medical University of Silesia, Silesian Center of Heart Diseases, Zabrze, Poland
- Medical University of Silesia, Division of Medical Sciences, Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Center for Heart Diseases, Zabrze, Poland
| | - Arian Sultan
- Department of Electrophysiology, Heart Center at University Hospital Cologne, Cologne, Germany
| | - Michael Brunner
- Department of Cardiology and Medical Intensive Care, St Josefskrankenhaus, Freiburg, Germany
| | - Avi Sabbag
- The Davidai Center for Rhythm Disturbances and Pacing, Chaim Sheba Medical Center, Ramat Gan, Israel
| | - Emin Evren Özcan
- Heart Rhythm Management Center, Dokuz Eylul University, İzmir, Turkey
| | - Jorge Toquero Ramos
- Cardiac Arrhythmia and Electrophysiology Unit, Cardiology Department, Puerta de Hierro University Hospital, Majadahonda, Madrid, Spain
| | - Giuseppe Di Stolfo
- Cardiac Intensive Care and Arrhythmology Unit, Fondazione IRCCS Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy
| | - Mahmoud Suleiman
- Cardiology/Electrophysiology, Rambam Health Care Campus, Haifa, Israel
| | | | | | - Ivan Cakulev
- University Hospitals of Cleveland, Case Western University, Cleveland, OH, USA
| | - Gabriel Eidelman
- San Isidro's Central Hospital, Diagnóstico Maipú, Buenos Aires Province, Argentina
| | - Wee Tiong Yeo
- Department of Cardiology, National University Heart Centre, Singapore, Singapore
| | - Dennis H Lau
- Centre for Heart Rhythm Disorders, The University of Adelaide and Royal Adelaide Hospital, Adelaide, SA, Australia
| | | | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, and Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Frank Heinzel
- Department of Cardiology, Charité University Medicine, Campus Virchow-Klinikum, 13353 Berlin, Germany
| | - Mukundaprabhu Prabhu
- Associate Professor in Cardiology, In charge of EP Division, Kasturba Medical College Manipal, Manipal, Karnataka, India
| | | | - Frederic Sacher
- Bordeaux University Hospital, Univ. Bordeaux, Bordeaux, France
| | - Raul Guillen
- Sanatorio Adventista del Plata, Del Plata Adventist University Entre Rios Argentina, Entre Rios, Argentina
| | - Jan de Pooter
- Professor of Cardiology, Ghent University, Deputy Head of Clinic, Heart Center UZ Gent, Ghent, Belgium
| | - Estelle Gandjbakhch
- AP-HP Sorbonne Université, Hôpital Pitié-Salpêtrière, Institut de Cardiologie, ICAN, Paris, France
| | - Seth Sheldon
- The Department of Cardiovascular Medicine, University of Kansas Health System, Kansas City, KS 66160, USA
| | | | - Pamela K Mason
- Director, Electrophysiology Laboratory, University of Virginia, Charlottesville, VA, USA
| | - Stephanie Fichtner
- LMU Klinikum, Medizinische Klinik und Poliklinik I, Campus Großhadern, München, Germany
| | - Takashi Nitta
- Emeritus Professor, Nippon Medical School, Presiding Consultant of Cardiology, Hanyu General Hospital, Saitama, Japan
| |
Collapse
|
6
|
Barcellini A, Dusi V, Mirandola A, Ronchi S, Riva G, Dal Mas F, Massaro M, Vitolo V, Ciocca M, Rordorf R, Orlandi E. The impact of particle radiotherapy on the functioning of cardiac implantable electronic devices: a systematic review of in vitro and in vivo studies according to PICO criteria. LA RADIOLOGIA MEDICA 2022; 127:1046-1058. [PMID: 35871428 PMCID: PMC9508006 DOI: 10.1007/s11547-022-01520-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 06/20/2022] [Indexed: 12/24/2022]
Abstract
The number of oncological patients who may benefit from proton beam radiotherapy (PBT) or carbon ion radiotherapy (CIRT), overall referred to as particle radiotherapy (RT), is expected to strongly increase in the next future, as well as the number of cardiological patients requiring cardiac implantable electronic devices (CIEDs). The management of patients with a CIED requiring particle RT deserves peculiar attention compared to those undergoing conventional photon beam RT, mostly due to the potential generation of secondary neutrons by particle beams interactions. Current consensus documents recommend managing these patients as being at intermediate/high risk of RT-induced device malfunctioning regardless of the dose on the CIED and the beam delivery method used, despite the last one significantly affects secondary neutrons generation (very limited neutrons production with active scanning as opposed to the passive scattering technique). The key issues for the current review were expressed in four questions according to the Population, Intervention, Control, Outcome criteria. Three in vitro and five in vivo studies were included. Based on the available data, PBT and CIRT with active scanning have a limited potential to interfere with CIED that has only emerged from in vitro study so far, while a significant potential for neutron-related, not severe, CIED malfunctions (resets) was consistently reported in both clinical and in vitro studies with passive scattering.
Collapse
Affiliation(s)
- Amelia Barcellini
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Veronica Dusi
- Division of Cardiology, Department of Medical Sciences, AOU Città Della Salute e Della Scienza, University of Turin, Turin, Italy.
| | - Alfredo Mirandola
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Sara Ronchi
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Giulia Riva
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Francesca Dal Mas
- Department of Management, Ca' Foscari University of Venice, Venice, Italy
| | - Maurizio Massaro
- Department of Management, Ca' Foscari University of Venice, Venice, Italy
| | - Viviana Vitolo
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Mario Ciocca
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Roberto Rordorf
- Coronary Care Unit and Laboratory of Clinical and Experimental Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Ester Orlandi
- Radiation Oncology, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| |
Collapse
|
7
|
The Effects of Pencil Beam Scanning Proton Beam Therapy on a HeartMate 3 Left Ventricular Assist Device. ASAIO J 2022; 68:e145-e147. [DOI: 10.1097/mat.0000000000001677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
8
|
Stick LB, Lægdsmand PMT, Bjerre HL, Høyer M, Jensen K, Jensen MF, Kronborg MB, Offersen BV, Kronborg CJS. Spot-scanning proton therapy for targets with adjacent cardiac implantable electronic devices - Strategies for breast and head & neck cancer. Phys Imaging Radiat Oncol 2022; 21:66-71. [PMID: 35243034 PMCID: PMC8861136 DOI: 10.1016/j.phro.2022.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 02/11/2022] [Accepted: 02/11/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND AND PURPOSE Cardiac implantable electronic device (CIED) malfunctions can be induced by secondary neutron dose from spot-scanning proton therapy. A recent in-vitro study investigating secondary neutron dose to CIEDs up to 7 mSv per fraction found that exposure of secondary neutrons in this range was clinically manageable. This study presents decision algorithms proposed by a national expert group for selection of patients with breast and head & neck (H&N) cancer with CIEDs adjacent to target for proton therapy based on the 7 mSv threshold. METHODS AND MATERIALS Ten patients with breast cancer and five with H&N cancer were included in the study. Five patients with breast cancer received photon therapy with CIED and proton plans were retrospectively created. The remaining patients received proton therapy without CIED and a worst-case position of a virtual CIED was retrospectively delineated. Secondary neutron dose was estimated as ambient dose equivalent H*(10) using Monte Carlo simulations. RESULTS For patients with breast cancer and with contralateral CIED, the secondary neutron dose to the CIED was below 7 mSv per fraction for CTV < 1500 cm3 in 2 Gy fractions and CTV < 1000 cm3 in 2.67 Gy fractions. The secondary neutron dose to the CIED was below 7 mSv per fraction for all patients with H&N cancer. CONCLUSIONS Simulations of neutron exposure suggest that proton therapy is feasible for most patients with CIED adjacent to target. This forms the basis for decision algorithms for selection of patients with CIED for proton therapy.
Collapse
Affiliation(s)
| | | | - Henrik Laurits Bjerre
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Morten Høyer
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Kenneth Jensen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | | | | | - Birgitte Vrou Offersen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Experimental Clinical Oncology & Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | | |
Collapse
|