1
|
Wearing SC, Hooper SL, Langton CM, Keiner M, Horstmann T, Crevier-Denoix N, Pourcelot P. The Biomechanics of Musculoskeletal Tissues during Activities of Daily Living: Dynamic Assessment Using Quantitative Transmission-Mode Ultrasound Techniques. Healthcare (Basel) 2024; 12:1254. [PMID: 38998789 PMCID: PMC11241410 DOI: 10.3390/healthcare12131254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 06/18/2024] [Accepted: 06/19/2024] [Indexed: 07/14/2024] Open
Abstract
The measurement of musculoskeletal tissue properties and loading patterns during physical activity is important for understanding the adaptation mechanisms of tissues such as bone, tendon, and muscle tissues, particularly with injury and repair. Although the properties and loading of these connective tissues have been quantified using direct measurement techniques, these methods are highly invasive and often prevent or interfere with normal activity patterns. Indirect biomechanical methods, such as estimates based on electromyography, ultrasound, and inverse dynamics, are used more widely but are known to yield different parameter values than direct measurements. Through a series of literature searches of electronic databases, including Pubmed, Embase, Web of Science, and IEEE Explore, this paper reviews current methods used for the in vivo measurement of human musculoskeletal tissue and describes the operating principals, application, and emerging research findings gained from the use of quantitative transmission-mode ultrasound measurement techniques to non-invasively characterize human bone, tendon, and muscle properties at rest and during activities of daily living. In contrast to standard ultrasound imaging approaches, these techniques assess the interaction between ultrasound compression waves and connective tissues to provide quantifiable parameters associated with the structure, instantaneous elastic modulus, and density of tissues. By taking advantage of the physical relationship between the axial velocity of ultrasound compression waves and the instantaneous modulus of the propagation material, these techniques can also be used to estimate the in vivo loading environment of relatively superficial soft connective tissues during sports and activities of daily living. This paper highlights key findings from clinical studies in which quantitative transmission-mode ultrasound has been used to measure the properties and loading of bone, tendon, and muscle tissue during common physical activities in healthy and pathological populations.
Collapse
Affiliation(s)
- Scott C. Wearing
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | - Sue L. Hooper
- School of Health, University of the Sunshine Coast, Sippy Downs, QLD 4556, Australia
| | - Christian M. Langton
- Griffith Centre of Rehabilitation Engineering, Griffith University, Southport, QLD 4222, Australia
| | - Michael Keiner
- Department of Exercise and Training Science, German University of Health and Sport, 85737 Ismaning, Bavaria, Germany
| | - Thomas Horstmann
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | | | - Philippe Pourcelot
- INRAE, BPLC Unit, Ecole Nationale Vétérinaire d’Alfort, 94700 Maisons-Alfort, France
| |
Collapse
|
2
|
Aftabi H, Sagl B, Lloyd JE, Prisman E, Hodgson A, Fels S. To what extent can mastication functionality be restored following mandibular reconstruction surgery? A computer modeling approach. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 250:108174. [PMID: 38640839 DOI: 10.1016/j.cmpb.2024.108174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 03/26/2024] [Accepted: 04/10/2024] [Indexed: 04/21/2024]
Abstract
STATEMENT OF PROBLEM Advanced cases of head and neck cancer involving the mandible often require surgical removal of diseased sections and subsequent replacement with donor bone. During the procedure, the surgeon must make decisions regarding which bones or tissues to resect. This requires balancing tradeoffs related to issues such as surgical access and post-operative function; however, the latter is often difficult to predict, especially given that long-term functionality also depends on the impact of post-operative rehabilitation programs. PURPOSE To assist in surgical decision-making, we present an approach for estimating the effects of reconstruction on key aspects of post-operative mandible function. MATERIAL AND METHODS We develop dynamic biomechanical models of the reconstructed mandible considering different defect types and validate them using literature data. We use these models to estimate the degree of functionality that might be achieved following post-operative rehabilitation. RESULTS We find significant potential for restoring mandibular functionality, even in cases involving large defects. This entails an average trajectory error below 2 mm, bite force comparable to a healthy individual, improved condyle mobility, and a muscle activation change capped at a maximum of 20%. CONCLUSION These results suggest significant potential for adaptability in the masticatory system and improved post-operative rehabilitation, leading to greater restoration of jaw function.
Collapse
Affiliation(s)
- Hamidreza Aftabi
- Department of ECE, University of British Columbia, Vancouver, V6T 1Z4, BC, Canada.
| | - Benedikt Sagl
- Center for Clinical Research, University Clinic of Dentistry, Medical University of Vienna, Vienna, 1090, Austria
| | - John E Lloyd
- Department of ECE, University of British Columbia, Vancouver, V6T 1Z4, BC, Canada
| | - Eitan Prisman
- Department of Surgery, University of British Columbia, Gordon and Leslie Diamond Health Care Centre, Vancouver, V5Z 1M9, BC, Canada
| | - Antony Hodgson
- Department of Mechanical Engineering, University of British Columbia, Vancouver, V6T 1Z4, BC, Canada
| | - Sidney Fels
- Department of ECE, University of British Columbia, Vancouver, V6T 1Z4, BC, Canada
| |
Collapse
|
3
|
Roffmann O, Stiesch M, Greuling A. Preventing stress singularities in peri-implant bone - a finite element analysis using a graded bone model. Comput Methods Biomech Biomed Engin 2024; 27:547-557. [PMID: 36942632 DOI: 10.1080/10255842.2023.2190832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 02/27/2023] [Indexed: 03/23/2023]
Abstract
In finite element analysis bone is often treated as two-layered material that has a discontinuity between the cortical and cancellous bone, which leads to a singularity and incorrect stresses. The goal of this study was to eliminate this singularity and to create a more realistic representation of bone which also considers the transition zone between cortical and cancellous bone as observed in natural bone. This was achieved by modelling bone as a graded material and inserting node-specific values for Young's modulus in the finite element simulation, whereas the transition zone thickness was derived from a CT scan. The modelling was performed semi-automatically, and the maximum principal stresses of the new approach were compared to those of a conventional approach. The new approach was found to effectively avoid singularities and provides more accurate predictions of stress in areas of the bone transition zone. As the approach is automatable and causes rather small overhead it is recommended for use in future work, when the problem at hand requires evaluating stresses close to the former singularity.
Collapse
Affiliation(s)
- Oliver Roffmann
- Department of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, Hannover, Germany
| | - Meike Stiesch
- Department of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, Hannover, Germany
| | - Andreas Greuling
- Department of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, Hannover, Germany
| |
Collapse
|
4
|
Jerban S, Barrere V, Namiranian B, Wu Y, Alenezi S, Dorthe E, Dlima D, Shah SB, Chung CB, Du J, Andre MP, Chang EY. Ultrasound attenuation of cortical bone correlates with biomechanical, microstructural, and compositional properties. Eur Radiol Exp 2024; 8:21. [PMID: 38316687 PMCID: PMC10844174 DOI: 10.1186/s41747-023-00418-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 12/09/2023] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient (α), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). METHODS SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (μCT) at 9-μm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. RESULTS α demonstrated significant positive Spearman correlations with E (R = 0.69) and BMD (R = 0.44) while showing significant negative correlations with porosity (R = -0.41), T2-MM (R = -0.47), TWPD (R = -0.68), BWPD (R = -0.67), and PWPD (R = -0.45). CONCLUSIONS The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. RELEVANCE STATEMENT This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. KEY POINTS • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA.
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA.
| | - Victor Barrere
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA
| | - Behnam Namiranian
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA
| | - Yuanshan Wu
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA
| | - Salem Alenezi
- Research and Laboratories Sector, Saudi Food and Drug Authority, Riyadh, Kingdom of Saudi Arabia
| | - Erik Dorthe
- Shiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA
| | - Darryl Dlima
- Shiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA
| | - Sameer B Shah
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
| | - Michael P Andre
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA, 92093, USA.
- Research Service, Veterans Affairs San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA, 92161, USA.
| |
Collapse
|
5
|
Jerban S, Jang H, Chang EY, Bukata S, Du J, Chung CB. Bone Biomarkers Based on Magnetic Resonance Imaging. Semin Musculoskelet Radiol 2024; 28:62-77. [PMID: 38330971 DOI: 10.1055/s-0043-1776431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
Magnetic resonance imaging (MRI) is increasingly used to evaluate the microstructural and compositional properties of bone. MRI-based biomarkers can characterize all major compartments of bone: organic, water, fat, and mineral components. However, with a short apparent spin-spin relaxation time (T2*), bone is invisible to conventional MRI sequences that use long echo times. To address this shortcoming, ultrashort echo time MRI sequences have been developed to provide direct imaging of bone and establish a set of MRI-based biomarkers sensitive to the structural and compositional changes of bone. This review article describes the MRI-based bone biomarkers representing total water, pore water, bound water, fat fraction, macromolecular fraction in the organic matrix, and surrogates for mineral density. MRI-based morphological bone imaging techniques are also briefly described.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, La Jolla, California
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, La Jolla, California
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
| | - Susan Bukata
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, California
| | - Jiang Du
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
- Department of Bioengineering, University of California, San Diego, La Jolla, California
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
| |
Collapse
|
6
|
Córdova-Fraga T, García-Pérez M, Hernández-Rayas A, Gómez-Solís C, Soto-Álvarez JA, Oliva J. Bone samples' behavior in sunlight, IR light, and temperature increase with FEM simulation. Med Biol Eng Comput 2024; 62:225-236. [PMID: 37770813 DOI: 10.1007/s11517-023-02929-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 09/05/2023] [Indexed: 09/30/2023]
Abstract
Biological and environmental factors produce biochemical processes that modify the bone structure. A few studies have attempted to show the adverse biological effects of sun radiation. The bone tissue exposures to infrared and sunlight radiation are analyzed by using focused sound, characterization spectroscopy techniques, and image processing. The study is complemented with a finite element method simulation on temperature behaviors. The crystal morphology on the bone hydroxyapatite and functional groups was characterized by X-ray diffraction and infrared spectroscopy. The infrared spectra confirmed the hydroxyl group of bovine hydroxyapatite, amines, and lipids are also correlated with modifications of the hydroxyapatite. The diffractograms showed the characteristic peaks of hydroxyapatite, with the main intensity at 2θ = 32.02°. Bone samples exposed to sun radiation presented a peak at 2θ = 27.5°, evidencing the possible formation of β-TCP y α-TCP. The analysis with the spectroscopy techniques about the structural changes in the samples suggests interpreting an increase of sound obtained by expanding the exposure time. It is possible to verify that there are some structural changes in the bone samples due to exposure to non-ionizing radiation. These results show an increase in the registered intensity sound correlated with the interpretation of the structural changes of bone. Thanks to the different novel analysis techniques established in the present study, it could establish the changes that experienced the bone structure under different sources of radiation, which will help to better detect scenarios of bone deficiency.
Collapse
Affiliation(s)
- Teodoro Córdova-Fraga
- Departamento de Ingeniería Física - DCI, Universidad de Guanajuato Campus León Loma del Bosque 103, Lomas del Campestre, 37150, León, GTO, Mexico.
| | - Marysol García-Pérez
- Departamento de Ingeniería Física - DCI, Universidad de Guanajuato Campus León Loma del Bosque 103, Lomas del Campestre, 37150, León, GTO, Mexico
| | - Angélica Hernández-Rayas
- Departamento de Ingeniería Física - DCI, Universidad de Guanajuato Campus León Loma del Bosque 103, Lomas del Campestre, 37150, León, GTO, Mexico
| | - Christian Gómez-Solís
- Departamento de Ingeniería Física - DCI, Universidad de Guanajuato Campus León Loma del Bosque 103, Lomas del Campestre, 37150, León, GTO, Mexico
| | - José Alfredo Soto-Álvarez
- Departamento de Ingeniería Física - DCI, Universidad de Guanajuato Campus León Loma del Bosque 103, Lomas del Campestre, 37150, León, GTO, Mexico
| | - Jorge Oliva
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Juriquilla, Querétaro, 76230, Mexico
| |
Collapse
|
7
|
Jafariandehkordi A, Daneshmehr A. Studying the mechanical properties of the mandible and injury prediction under the effect of ossification factors. J Mech Behav Biomed Mater 2023; 148:106209. [PMID: 37918338 DOI: 10.1016/j.jmbbm.2023.106209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/19/2023] [Accepted: 10/23/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND AND OBJECTIVE It is essential to know the quantitative interactions between biological tissues and external mechanical and chemical stimuli. This assists the physicians to better know the quantitative behavior of the tissue and plan more effective therapy. In the literature, the effect of the chemical and mechanical loading was investigated on the bone biological cell activities and some mechanical features, but a lack of prediction of bone injury under the chemical and mechanical factors was sensed. Therefore, the present study aims to investigate the effects of the application of major chemical factors involved in ossification, including RANKL1 (Receptor Activator of Nuclear Factor Kappa Beta Ligand), PTH2 (Parathyroid Hormone), and OPG3 (Osteoprotegerin) on the mandibular bone biological osteoblast and osteoclast activities and mechanical properties. Moreover, the study assesses the bone injury possibility under uniform mastication pressure applied on the premolar tooth in terms of the mechanostat theory undergoing the effects of the chemical factors. METHODS A 3D geometry of the mandible-tooth assembly was generated from the CT image dataset. The geometry was next purified, solidified, and exported to FEM4 (Finite Element Method) software to be meshed, where boundary conditions and loading were applied. Moreover, the mathematical system of differential equations to model the chemical factor effects on osteoblast and osteoclast activities as well as bone matrix volume fraction and elastic stiffness relations were applied. Next, the values of the equivalent strain were calculated to predict the injury states of the bone. RESULTS The results complied with the literature data. The results showed that RANKL and PTH increased the values of the equivalent strain from 450 με to 11500 με, while OPG reduced that from 450 με to 300 με. CONCLUSIONS Therefore, RANKL and PTH doses of this study put the bone at risk of injury compared to the baseline of no dose applied, while OPG secured the bone from injury.
Collapse
|
8
|
Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, Alshammari AS, Misran N, Soliman MS, Mahmud S, Khandakar A. Advancement in total hip implant: a comprehensive review of mechanics and performance parameters across diverse novelties. J Mater Chem B 2023; 11:10507-10537. [PMID: 37873807 DOI: 10.1039/d3tb01469j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
Collapse
Affiliation(s)
- Md Mohiuddin Soliman
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohammad Tariqul Islam
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Muhammad E H Chowdhury
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Abdulrahman Alqahtani
- Department of Medical Equipment Technology, College of Applied, Medical Science, Majmaah University, Majmaah City 11952, Saudi Arabia
- Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia.
| | - Farayi Musharavati
- Department of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.
| | - Touhidul Alam
- Pusat Sains Ankasa (ANGKASA), Institut Perubahan Iklim, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.
| | - Ahmed S Alshammari
- Department of Electrical Engineering, College of Engineering, University Hail, Hail 81481, Saudi Arabia.
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
| | - Norbahiah Misran
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohamed S Soliman
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
- Department of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, 81528, Egypt
| | - Sakib Mahmud
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Amith Khandakar
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| |
Collapse
|
9
|
Szabó ÁL, Matusovits D, Slyteen H, Lakatos ÉI, Baráth Z. Biomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA). Dent J (Basel) 2023; 11:261. [PMID: 37999025 PMCID: PMC10670282 DOI: 10.3390/dj11110261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/29/2023] [Accepted: 11/03/2023] [Indexed: 11/25/2023] Open
Abstract
The long-term success and predictability of implant-supported restorations largely depends on the biomechanical forces (stresses) acting on implants and the surrounding alveolar bone in the mandible. The aim of our study was to investigate the biomechanical behavior of an edentulous mandible with an implant-supported full bridge on four implants under simulated masticatory forces, in the context of different loading schemes, using a three-dimensional finite element analysis (3D-FEA). A patient-specific 3D finite element model was constructed using pre- and post-implantation computer tomography (CT) images of a patient undergoing implant treatment. Simplified masticatory forces set at 300 N were exerted vertically on the denture in four different simulated load cases (LC1-LC4). Two sets of simulations for different implants and denture materials (S1: titanium and titanium; S2: titanium and cobalt-chromium, respectively) were made. Stress outputs were taken as maximum (Pmax) and minimum principal stress (Pmin) and equivalent stress (Peqv) values. The highest peak Pmax values were observed for LC2 (where the modelled masticatory force excluded the cantilevers of the denture extending behind the terminal implants), both regarding the cortical bone (S1 Pmax: 89.57 MPa, S2 Pmax: 102.98 MPa) and trabecular bone (S1 Pmax: 3.03 MPa, S2 Pmax: 2.62 MPa). Overall, LC1-where masticatory forces covered the entire mesio-distal surface of the denture, including the cantilever-was the most advantageous. Peak Pmax values in the cortical bone and the trabecular bone were 14.97-15.87% and 87.96-94.54% higher in the case of S2, respectively. To ensure the long-term maintenance and longevity of treatment for implant-supported restorations in the mandible, efforts to establish the stresses of the surrounding bone in the physiological range, with the most even stress distribution possible, have paramount importance.
Collapse
Affiliation(s)
- Árpád László Szabó
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66., 6720 Szeged, Hungary; (Á.L.S.); (D.M.)
| | - Danica Matusovits
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66., 6720 Szeged, Hungary; (Á.L.S.); (D.M.)
| | - Haydar Slyteen
- Department of Structural Mechanics, Faculty of Civil Engineering, University of Technology and Economics, Budapest, Műegyetem rkp. 3., 1111 Budapest, Hungary; (H.S.); (É.I.L.)
| | - Éva Ilona Lakatos
- Department of Structural Mechanics, Faculty of Civil Engineering, University of Technology and Economics, Budapest, Műegyetem rkp. 3., 1111 Budapest, Hungary; (H.S.); (É.I.L.)
| | - Zoltán Baráth
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66., 6720 Szeged, Hungary; (Á.L.S.); (D.M.)
| |
Collapse
|
10
|
Pereira LF, Fontes-Pereira AJ, de Albuquerque Pereira WC. Influence of Low-Intensity Pulsed Ultrasound Parameters on the Bone Mineral Density in Rat Model: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1687-1698. [PMID: 37121881 DOI: 10.1016/j.ultrasmedbio.2023.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 02/23/2023] [Accepted: 03/03/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Bone recovery typically depends on the age of organisms or the prevalence of metabolic disorders such as osteoporosis, which is a metabolic condition characterized by decreased bone strength and bone mineral density (BMD). Therefore, low-intensity pulsed ultrasound (LIPUS), a non-invasive method for osteogenic stimulation, presents promising results. However, heterogeneity in animal study designs is a typical characteristic. Hence, we conducted a systematic review to evaluate the effectiveness of LIPUS in the recovery of experimental bone defects using rat models. We examined the areal and volumetric BMD to identify LIPUS doses to be applied and evaluated the accuracy reported by previous studies. METHODS The Virtual Health Library regional portal, PubMed, Embase, EBSCOhost, Scopus and CAPES were reviewed for animal studies that compared fracture treatments based on LIPUS with sham or no treatments using rat models and reported BMD as an outcome. The tool provided by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE) and the Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) checklist were used to assess the bias and quality of such studies. RESULTS Of the six studies reviewed, the most frequently used LIPUS dose had an ultrasonic frequency of 1.0 MHz, repetition rate of 0.1 kHz and pulse duration of 2000 μs. An intensity (ISATA) of 30 mW/cm2 was the most preferred for bone recovery. However, the BMD could not solely irrefutably evaluate the effectiveness of LIPUS in bone recovery as the results were discordant with each other. The discrepancies in experimental methodologies, low-quality classifications and high risk of bias in the selected studies, however, did not validate the undertaking of a meta-analysis. CONCLUSION On the basis of the BMD results, no sufficient evidence was found to recommend the use of LIPUS for bone recovery in rat models. Thus, this systematic review indicates that the accuracy of such reports must be improved to improve their scientific quality to facilitate a transition of LIPUS applications from pre-clinical research to clinic use.
Collapse
Affiliation(s)
- Luiz Fernando Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
| | - Aldo José Fontes-Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Centro Universitário Serra dos Órgãos-Unifeso, Teresópolis, Rio de Janeiro, Brazil
| | | |
Collapse
|
11
|
Lukina Y, Safronova T, Smolentsev D, Toshev O. Calcium Phosphate Cements as Carriers of Functional Substances for the Treatment of Bone Tissue. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4017. [PMID: 37297151 PMCID: PMC10254876 DOI: 10.3390/ma16114017] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/14/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023]
Abstract
Interest in calcium phosphate cements as materials for the restoration and treatment of bone tissue defects is still high. Despite commercialization and use in the clinic, the calcium phosphate cements have great potential for development. Existing approaches to the production of calcium phosphate cements as drugs are analyzed. A description of the pathogenesis of the main diseases of bone tissue (trauma, osteomyelitis, osteoporosis and tumor) and effective common treatment strategies are presented in the review. An analysis of the modern understanding of the complex action of the cement matrix and the additives and drugs distributed in it in relation to the successful treatment of bone defects is given. The mechanisms of biological action of functional substances determine the effectiveness of use in certain clinical cases. An important direction of using calcium phosphate cements as a carrier of functional substances is the volumetric incorporation of anti-inflammatory, antitumor, antiresorptive and osteogenic functional substances. The main functionalization requirement for carrier materials is prolonged elution. Various release factors related to the matrix, functional substances and elution conditions are considered in the work. It is shown that cements are a complex system. Changing one of the many initial parameters in a wide range changes the final characteristics of the matrix and, accordingly, the kinetics. The main approaches to the effective functionalization of calcium phosphate cements are considered in the review.
Collapse
Affiliation(s)
- Yulia Lukina
- National Medical Research Center for Traumatology and Orthopedics Named after N.N. Priorov, Ministry of Health of the Russian Federation, Priorova 10, 127299 Moscow, Russia;
- Faculty of Digital Technologies and Chemical Engineering, Mendeleev University of Chemical Technology of Russia, Miusskaya pl. 9, 125047 Moscow, Russia
| | - Tatiana Safronova
- Department of Chemistry, Lomonosov Moscow State University, Building 3, Leninskie Gory 1, 119991 Moscow, Russia;
- Department of Materials Science, Lomonosov Moscow State University, Building 73, Leninskie Gory 1, 119991 Moscow, Russia;
| | - Dmitriiy Smolentsev
- National Medical Research Center for Traumatology and Orthopedics Named after N.N. Priorov, Ministry of Health of the Russian Federation, Priorova 10, 127299 Moscow, Russia;
| | - Otabek Toshev
- Department of Materials Science, Lomonosov Moscow State University, Building 73, Leninskie Gory 1, 119991 Moscow, Russia;
| |
Collapse
|
12
|
Hafizh M, Soliman MM, Qiblawey Y, Chowdhury MEH, Islam MT, Musharavati F, Mahmud S, Khandakar A, Nabil M, Nezhad EZ. Surface Acoustic Wave (SAW) Sensors for Hip Implant: A Numerical and Computational Feasibility Investigation Using Finite Element Methods. BIOSENSORS 2023; 13:79. [PMID: 36671914 PMCID: PMC9855817 DOI: 10.3390/bios13010079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/25/2022] [Accepted: 12/15/2022] [Indexed: 06/17/2023]
Abstract
In this paper, a surface acoustic wave (SAW) sensor for hip implant geometry was proposed for the application of total hip replacement. A two-port SAW device was numerically investigated for implementation with an operating frequency of 872 MHz that can be used in more common radio frequency interrogator units. A finite element analysis of the device was developed for a lithium niobate (LiNBO3) substrate with a Rayleigh velocity of 3488 m/s on COMSOL Multiphysics. The Multiphysics loading and frequency results highlighted a good uniformity with numerical results. Afterwards, a hip implant geometry was developed. The SAW sensor was mounted at two locations on the implant corresponding to two regions along the shaft of the femur bone. Three discrete conditions were studied for the feasibility of the implant with upper- and lower-body loading. The loading simulations highlighted that the stresses experienced do not exceed the yield strengths. The voltage output results indicated that the SAW sensor can be implanted in the hip implant for hip implant-loosening detection applications.
Collapse
Affiliation(s)
- Muhammad Hafizh
- Department of Mechanical and Industrial Engineering, Qatar University, Doha 2713, Qatar
| | - Md Mohiuddin Soliman
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia
| | - Yazan Qiblawey
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | | | - Mohammad Tariqul Islam
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia
| | - Farayi Musharavati
- Department of Mechanical and Industrial Engineering, Qatar University, Doha 2713, Qatar
| | - Sakib Mahmud
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | - Amith Khandakar
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | - Mohammad Nabil
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | - Erfan Zal Nezhad
- Department of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| |
Collapse
|
13
|
Dia AS, Renaud G, Nooghabi AH, Grimal Q. The influence of intra-cortical microstructure on the contrast in ultrasound images of the cortex of long bones: A 2D simulation study. ULTRASONICS 2023; 127:106831. [PMID: 36084514 DOI: 10.1016/j.ultras.2022.106831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 07/14/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
Decreased thickness of the bone cortex due to bone loss in the course of ageing and osteoporosis is associated with reduced bone strength. Cortical thickness measurement from ultrasound images was recently demonstrated in young adults. This requires the identification of both the outer (periosteum) and inner (endosteum) surfaces of the bone cortex. However, with bone loss, the cortical porosity and the size of the vascular pores increase resulting in enhanced ultrasound scattering which may prevent the detection of the endosteum. The aim of this work was to study the influence of cortical bone microstructure variables, such as porosity and pore size, on the contrast of the endosteum in ultrasound images. We wanted to estimate the range of these variables for which ultrasound imaging of the endosteum is feasible. We generated synthetic data using a two-dimensional time-domain code to simulate the propagation of elastodynamic waves. A synthetic aperture imaging sequence with an array transducer operating at a center frequency of 2.5 MHz was used. The numerical simulations were conducted for 105 cortical microstructures obtained from high resolution X-ray computed tomography images of ex vivo bone samples with a porosity ranging from 2% to 24 %. Images were reconstructed using a delay-and-sum (DAS) algorithm with optimized f-number, correction of refraction at the periosteum, and sample-specific wave-speed. We observed a range variation of 18 dB of endosteum contrast in our data set depending on the bone microstructure. We found that as porosity increases, speckle intensity inside the bone cortex increases whereas the intensity of the signal from the endosteum decreases. Also, a microstructure with large pores (diameter >250 μm) was associated with poor endosteum visibility, compared with a microstructure with equal porosity but a more narrow distribution of pore sizes. These findings suggest that ultrasound imaging of the bone cortex with a probe operating at a central frequency of 2.5 MHz using refraction-corrected DAS is capable of detecting the endosteum of a cortex with moderate porosity (less than about 10%) if the largest pores remain smaller than about 200 μm.
Collapse
Affiliation(s)
- Amadou Sall Dia
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France.
| | - Guillaume Renaud
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France; Department of Imaging Physics, Delft University of Technology, The Netherlands
| | - Aida Hejazi Nooghabi
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France
| | - Quentin Grimal
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France
| |
Collapse
|
14
|
Tran TNHT, Le LH, Ta D. Ultrasonic Guided Waves in Bone: A Decade of Advancement in Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2875-2895. [PMID: 35930519 DOI: 10.1109/tuffc.2022.3197095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The use of guided wave ultrasonography as a means to assess cortical bone quality has been a significant practice in bone quantitative ultrasound for more than 20 years. In this article, the key developments within the technology of ultrasonic guided waves (UGW) in long bones during the past decade are documented. The covered topics include data acquisition configurations available for measuring bone guided waveforms, signal processing techniques applied to bone UGW, numerical modeling of ultrasonic wave propagation in cortical long bones, formulation of inverse approaches to extract bone properties from observed ultrasonic signals, and clinical studies to establish the technology's application and efficacy. The review concludes by highlighting specific challenging problems and future research directions. In general, the primary purpose of this work is to provide a comprehensive overview of bone guided-wave ultrasound, especially for newcomers to this scientific field.
Collapse
|
15
|
Webb TD, Fu F, Leung SA, Ghanouni P, Dahl JJ, Does MD, Pauly KB. Improving Transcranial Acoustic Targeting: The Limits of CT-Based Velocity Estimates and the Role of MR. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2630-2637. [PMID: 35853046 PMCID: PMC9519088 DOI: 10.1109/tuffc.2022.3192224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) enables the noninvasive treatment of the deep brain. This capacity relies on the ability to focus acoustic energy through the in-tact skull, a feat that requires accurate estimates of the acoustic velocity in individual patient skulls. In current practice, these estimates are generated using a pretreatment computed tomography (CT) scan and then registered to a magnetic resonance (MR) dataset on the day of the treatment. Treatment safety and efficacy can be improved by eliminating the need to register the CT data to the MR images and by improving the accuracy of acoustic velocity measurements. In this study, we examine the capacity of MR to supplement or replace CT as a means of estimating velocity in the skull. We find that MR can predict velocity with less but comparable accuracy to CT. We then use micro-CT imaging to better understand the limitations of Hounsfield unit (HU)-based estimates of velocity, demonstrating that the macrostructure of pores in the skull contributes to the acoustic velocity of the bone. We find evidence that detailed T2 measurements provide information about pore macrostructure similar to the information obtained with micro-CT, offering a potential clinical mechanism for improving patient-specific estimates of acoustic velocity in the human skull.
Collapse
|
16
|
Song S, Chen H, Li C, Lou E, Le LH, Zheng R. Assessing Bone Quality of the Spine in Children with Scoliosis Using the Ultrasound Reflection Frequency Amplitude Index Method: A Preliminary Study. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:808-819. [PMID: 35181172 DOI: 10.1016/j.ultrasmedbio.2022.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 12/22/2021] [Accepted: 01/06/2022] [Indexed: 06/14/2023]
Abstract
Osteopenia is considered a common phenomenon in patients who have scoliosis. Quantitative ultrasound has been used to assess skeletal status for decades, and recently ultrasound imaging using reflection signals from vertebrae were as well applied to measure spinal curvatures in children with scoliosis. The objectives of this study were to develop a new method that can robustly extract a parameter from ultrasound spinal data for estimating bone quality of scoliotic patients and to investigate the potential of the parameter in predicting curve progression. The frequency amplitude index (FAI) was calculated based on the spectrum of the original radiofrequency signals reflected from the tissue-vertebra interface. The correlation between FAI and reflection coefficient was validated using decalcified bovine bone samples in vitro, and the FAIs of scoliotic subjects were investigated in vivo with reference to body mass index, Cobb angles and curve progression status. The results revealed that the intra-rater measures were highly reliable between different trials (intra-class correlation coefficient = 0.997). The FAI value was strongly correlated with the reflection coefficient of bone tissue (R2 = 0.824), and the lower FAI indicated the higher risk of curve progression for the non-mild scoliosis cases. This preliminary study found that the FAI method can provide a feasible and robust approach to assessment of the bone quality of spine and may be a promising factor in monitoring curve progression of patients who have adolescent idiopathic scoliosis.
Collapse
Affiliation(s)
- Sheng Song
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Hongbo Chen
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China; Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China; University of Chinese Academy of Sciences, Beijing, China
| | - Conger Li
- School of Physical Science and Technology, ShanghaiTech University, Shanghai, China
| | - Edmond Lou
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Rui Zheng
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China; Shanghai Engineering Research Center of Energy Efficient and Custom AI IC, ShanghaiTech University, Shanghai, China.
| |
Collapse
|
17
|
Mozaffarzadeh M, Verschuur E, Verweij MD, Daeichin V, De Jong N, Renaud G. Refraction-Corrected Transcranial Ultrasound Imaging Through the Human Temporal Window Using a Single Probe. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1191-1203. [PMID: 35100111 DOI: 10.1109/tuffc.2022.3148121] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound velocity of the aberrator (i.e., the skull) is estimated using the bidirectional headwave technique. The medium is described with four layers (i.e., lens, water, skull, and water), and a fast marching method calculates the travel times between individual array elements and image pixels. Finally, a delay-and-sum algorithm is used for image reconstruction with coherent compounding. The point spread function (PSF) in a wire phantom image and reconstructed with the conventional technique (using a constant sound speed throughout the medium), and the proposed method was quantified with numerical synthetic data and experiments with a bone-mimicking plate and a human skull, compared with the PSF achieved in a ground truth image of the medium without the aberrator (i.e., the bone plate or skull). A phased-array transducer (P4-1, ATL/Philips, 2.5 MHz, 96 elements, pitch = 0.295 mm) was used for the experiments. The results with the synthetic signals, the bone-mimicking plate, and the skull indicated that the proposed method reconstructs the scatterers with an average lateral/axial localization error of 0.06/0.14 mm, 0.11/0.13 mm, and 1.0/0.32 mm, respectively. With the human skull, an average contrast ratio (CR) and full-width-half-maximum (FWHM) of 37.1 dB and 1.75 mm were obtained with the proposed approach, respectively. This corresponds to an improvement of CR and FWHM by 7.1 dB and 36% compared with the conventional method, respectively. These numbers were 12.7 dB and 41% with the bone-mimicking plate.
Collapse
|
18
|
Mian SH, Moiduddin K, Elseufy SM, Alkhalefah H. Adaptive Mechanism for Designing a Personalized Cranial Implant and Its 3D Printing Using PEEK. Polymers (Basel) 2022; 14:1266. [PMID: 35335596 PMCID: PMC8955283 DOI: 10.3390/polym14061266] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/07/2022] [Accepted: 03/16/2022] [Indexed: 12/29/2022] Open
Abstract
The rehabilitation of the skull's bones is a difficult process that poses a challenge to the surgical team. Due to the range of design methods and the availability of materials, the main concerns are the implant design and material selection. Mirror-image reconstruction is one of the widely used implant reconstruction techniques, but it is not a feasible option in asymmetrical regions. The ideal design approach and material should result in an implant outcome that is compact, easy to fit, resilient, and provides the perfect aesthetic and functional outcomes irrespective of the location. The design technique for the making of the personalized implant must be easy to use and independent of the defect's position on the skull. As a result, this article proposes a hybrid system that incorporates computer tomography acquisition, an adaptive design (or modeling) scheme, computational analysis, and accuracy assessment. The newly developed hybrid approach aims to obtain ideal cranial implants that are unique to each patient and defect. Polyetheretherketone (PEEK) is chosen to fabricate the implant because it is a viable alternative to titanium implants for personalized implants, and because it is simpler to use, lighter, and sturdy enough to shield the brain. The aesthetic result or the fitting accuracy is adequate, with a maximum deviation of 0.59 mm in the outside direction. The results of the biomechanical analysis demonstrate that the maximum Von Mises stress (8.15 MPa), Von Mises strain (0.002), and deformation (0.18 mm) are all extremely low, and the factor of safety is reasonably high, highlighting the implant's load resistance potential and safety under high loading. Moreover, the time it takes to develop an implant model for any cranial defect using the proposed modeling scheme is very fast, at around one hour. This study illustrates that the utilized 3D reconstruction method and PEEK material would minimize time-consuming alterations while also improving the implant's fit, stability, and strength.
Collapse
Affiliation(s)
- Syed Hammad Mian
- Department of Industrial Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia; (K.M.); (S.M.E.); (H.A.)
| | - Khaja Moiduddin
- Department of Industrial Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia; (K.M.); (S.M.E.); (H.A.)
| | - Sherif Mohammed Elseufy
- Department of Industrial Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia; (K.M.); (S.M.E.); (H.A.)
| | - Hisham Alkhalefah
- Department of Industrial Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia; (K.M.); (S.M.E.); (H.A.)
| |
Collapse
|
19
|
Tran TN H T, Xu K, Le LH, Ta D. Signal Processing Techniques Applied to Axial Transmission Ultrasound. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:95-117. [DOI: 10.1007/978-3-030-91979-5_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Baron C, Follet H, Pithioux M, Payan C, Lasaygues P. Assessing the Elasticity of Child Cortical Bone. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:297-318. [DOI: 10.1007/978-3-030-91979-5_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
21
|
Chatzigeorgiou C, Piotrowski B, Chemisky Y, Laheurte P, Meraghni F. Numerical investigation of the effective mechanical properties and local stress distributions of TPMS-based and strut-based lattices for biomedical applications. J Mech Behav Biomed Mater 2021; 126:105025. [PMID: 34920324 DOI: 10.1016/j.jmbbm.2021.105025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 10/15/2021] [Accepted: 12/02/2021] [Indexed: 12/22/2022]
Abstract
Porous structures, including those with lattice geometries, have been shown to mimic the mechanical properties of the human bone. Apart from the widely known strut-based lattices, the Triply Periodic Minimal Surfaces (TPMS) concept has been introduced recently to create surface-based lattices and to tailor their mechanical behaviors. In this study, the numerical investigation of the effective elastic properties, the anisotropic behavior, and the local stress distributions of a broad range of topologies provide us with a complete numerical tool to assist bone implant design. The comparison database of the lattices includes TPMS-based lattices, both sheet, and skeletal, as well as strut-based lattices. The lattices are subjected to periodic boundary conditions and also, a homogenization method is deployed to simulate the response of the lattice unit cells determining their apparent equivalent stiffness. A correlation among the lattice topologies, their effective mechanical properties, and the local Von Mises stress concentrations in them is observed. The stress distribution of various topologies with the same elastic modulus is examined to combine all the investigations. Finally, a large variety of numerical results are presented to allow the comparison of the lattice structures and the selection of the optimal configuration that mimics the elastic properties of the bone.
Collapse
Affiliation(s)
- Chrysoula Chatzigeorgiou
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Boris Piotrowski
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Yves Chemisky
- Université de Bordeaux, I2M UMR CNRS 5295, Bordeaux, France
| | - Pascal Laheurte
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Fodil Meraghni
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France.
| |
Collapse
|
22
|
Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus 2021; 5:e10536. [PMID: 34761144 PMCID: PMC8567489 DOI: 10.1002/jbm4.10536] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 08/03/2021] [Indexed: 11/21/2022] Open
Abstract
Osteoporosis is a disorder of bone remodeling leading to reduced bone mass, structural deterioration, and increased bone fragility. The established diagnosis is based on the measurement of areal bone mineral density by dual‐energy X‐ray absorptiometry (DXA), which poorly captures individual bone loss and structural decay. Enlarged cortical pores in the tibia have been proposed to indicate structural deterioration and reduced bone strength in the hip. Here, we report for the first time the in vivo assessment of the cortical pore‐size distribution together with frequency‐dependent attenuation at the anteromedial tibia midshaft by means of a novel ultrasonic cortical backscatter (CortBS) technology. We hypothesized that the CortBS parameters are associated with the occurrence of fragility fractures in postmenopausal women (n = 55). The discrimination performance was compared with those of DXA and high‐resolution peripheral computed tomography (HR‐pQCT). The results suggest a superior discrimination performance of CortBS (area under the receiver operating characteristic curve [AUC]: 0.69 ≤ AUC ≤ 0.75) compared with DXA (0.54 ≤ AUC ≤ 0.55) and a similar performance compared with HR‐pQCT (0.66 ≤ AUC ≤ 0.73). CortBS is the first quantitative bone imaging modality that can quantify microstructural tissue deteriorations in cortical bone, which occur during normal aging and the development of osteoporosis. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Gabriele Armbrecht
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Center for Muscle and Bone Research Berlin Germany
| | - Huong Nguyen Minh
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Jonas Massmann
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Kay Raum
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| |
Collapse
|
23
|
Garcia-Perez M, Soto-Alvarez JA, Cordova-Fraga T. Focused ultrasound simulation through cortical bone by finite element method . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4362-4365. [PMID: 34892186 DOI: 10.1109/embc46164.2021.9630365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Bone tissue is constantly changed adapting to its mechanical environment and capable of repairing itself. Ultra-sound has recently been used as a diagnostic technique to assess bone conditions. To optimize the experimental model as best as possible computational simulation techniques have been focused on clinical applications in bone. This study aims to analyze by finite element method the propagation of ultrasound waves along the cortical bone. The wave propagation phenomenon is well studied and described by the Helmholtz equation. The first part of the work analytically solves the Helmholtz equation, and later the COMSOL Multiphysics software is used. It was established a cylindrical geometry as the bone sample. The software analyzes with "Pressure Acoustic, Frequency Domain" module. An extremely fine mesh is used for the solution in order not to lose information. According to the analytical solution, the results show the behavior of the acoustic pressure waves throughout the samples. In addition, attenuation coefficients are calculated for biological materials such as bone and muscle. Simulation methods allow to analyze adjustable parameters in the development of new devices. Thus, optimizing resources and allowing the researcher to better understanding the problem to be solved.
Collapse
|
24
|
Minonzio JG, Han C, Cassereau D, Grimal Q. In vivopulse-echo measurement of apparent broadband attenuation and Qfactor in cortical bone: a preliminary study. Phys Med Biol 2021; 66. [PMID: 34192679 DOI: 10.1088/1361-6560/ac1022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 06/30/2021] [Indexed: 11/11/2022]
Abstract
Quantitative ultrasound (QUS) methods have been introduced to assess cortical bone health at the radius and tibia through the assessment of cortical thickness (Ct.Th), cortical porosity and bulk wave velocities. Ultrasonic attenuation is another QUS parameter which is not currently used. We assessed the feasibility ofin vivomeasurement of ultrasonic attenuation in cortical bone with a broadband transducer with 3.5 MHz center frequency. Echoes from the periosteal and endosteal interfaces were fitted with Gaussian pulses using sparse signal processing. Then, the slope of the broadband ultrasonic attenuation (Ct.nBUA) in cortical bone and quality factorQ11-1were calculated with a parametric approach based on the center-frequency shift. Five human subjects were measured at the one-third distal radius with pulse-echo ultrasound, and reference data was obtained with high-resolution x-ray peripheral computed tomography (Ct.Th and cortical volumetric bone mineral density (Ct.vBMD)). Ct.Th was used in the calculation of Ct.nBUA whileQ11-1is obtained solely from ultrasound data. The values of Ct.nBUA (6.7 ± 2.2 dB MHz-1.cm-1) andQ11-1(8.6 ± 3.1%) were consistent with the literature data and were correlated to Ct.vBMD (R2=0.92,p<0.01, RMSE = 0.56 dB.MHz-1.cm-1, andR2=0.93,p<0.01, RMSE = 0.76%). This preliminary study suggests that the attenuation of an ultrasound signal propagating in cortical bone can be measuredin vivoat the one-third distal radius and that it provides an information on bone quality as attenuation values were correlated to Ct.vBMD. It remains to ascertain that Ct.nBUA andQ11-1measured here exactly reflect the true (intrinsic) ultrasonic attenuation in cortical bone. Measurement of attenuation may be considered useful for assessing bone health combined with the measurement of Ct.Th, porosity and bulk wave velocities in multimodal cortical bone QUS methods.
Collapse
Affiliation(s)
- Jean-Gabriel Minonzio
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France.,Escuela de Ingeniería Informática, Universidad de Valparaíso, Valparaíso 2362735, Chile.,Centro de Investigación y Desarrollo en Ingeniería en Salud, Universidad de Valparaíso, Valparaíso, Chile
| | - Chao Han
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| | - Didier Cassereau
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| | - Quentin Grimal
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| |
Collapse
|
25
|
Peralta L, Maeztu Redin JD, Fan F, Cai X, Laugier P, Schneider J, Raum K, Grimal Q. Bulk Wave Velocities in Cortical Bone Reflect Porosity and Compression Strength. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:799-808. [PMID: 33341302 DOI: 10.1016/j.ultrasmedbio.2020.11.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 11/16/2020] [Accepted: 11/16/2020] [Indexed: 06/12/2023]
Abstract
The goal of this study was to evaluate whether ultrasonic velocities in cortical bone can be considered as a proxy for mechanical quality of cortical bone tissue reflected by porosity and compression strength. Micro-computed tomography, compression mechanical testing and resonant ultrasound spectroscopy were used to assess, respectively, porosity, strength and velocity of bulk waves of both shear and longitudinal polarisations propagating along and perpendicular to osteons, in 92 cortical bone specimens from tibia and femur of elderly human donors. All velocities were significantly associated with strength (r = 0.65-0.83) and porosity (r = -0.64 to -0.77). Roughly, according to linear regression models, a decrease in velocity of 100 m/s corresponded to a loss of 20 MPa in strength (which is approximately 10% of the largest strength value) and to an increase in porosity of 5%. These results provide a rationale for the in vivo measurement of one or several velocities for the diagnosis of bone fragility.
Collapse
Affiliation(s)
- Laura Peralta
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, United Kingdom.
| | - Juan Deyo Maeztu Redin
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Fan Fan
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiran Cai
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Pascal Laugier
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Johannes Schneider
- Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany
| | - Kay Raum
- Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany
| | - Quentin Grimal
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| |
Collapse
|
26
|
Godebo TR, Jeuland M, Tekle-Haimanot R, Shankar A, Alemayehu B, Assefa G, Whitford G, Wolfe A. Bone quality in fluoride-exposed populations: A novel application of the ultrasonic method. Bone Rep 2020; 12:100235. [PMID: 31890757 PMCID: PMC6933268 DOI: 10.1016/j.bonr.2019.100235] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/04/2019] [Accepted: 12/05/2019] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Various studies, mostly with animals, have provided evidence of adverse impacts of fluoride (F-) on bone density, collagen and microstructure, yet its effects on overall bone quality (strength) has not been clearly or extensively characterized in human populations. OBJECTIVE In this observational study, we assessed variation in an integrated measures of bone quality in a population exposed to wide-ranging F- levels (0.3 to 15.5 mg/L) in drinking water, using a novel application of non-ionizing ultrasonic method. METHOD We collected 871 speed of sound (SOS) measurements from 341 subjects residing in 25 communities, aged 10-70 years (188 males and 153 females). All subjects received scans of the cortical radius and tibia, and adults over the age of 19 received an additional scan of the phalanx. Associations between F- in drinking water and 24-h urine samples, and SOS as a measure of bone quality, were evaluated in bivariate and multivariable regressions adjusting for age, sex, BMI, smoking, and toothpaste use. RESULTS We found negative associations between F- exposure and bone quality at all three bones. Adult tibial SOS showed the strongest inverse association with F- exposure, which accounted for 20% of the variance in SOS measures (r = 0.45; n = 199; p < 0.0001). In adjusted analysis, a 1 mg/L increase in F- in drinking water was related to a reduction of 15.8 m/s (95% CI: -21.3 to -10.3), whereas a 1 mg/L increase in 24-h urinary F- (range: 0.04-39.5 mg/L) was linked to a reduction of 8.4 m/s (95% CI: -12.7, -4.12) of adult tibial SOS. Among adolescents, in contrast, weaker and non-significant inverse associations between F- exposure and SOS were found, while age, gender, and BMI were more significant predictors than in adults. CONCLUSIONS These results are indicative of a fluoride-induced deterioration of bone quality in humans, likely reflecting a combination of factors related to SOS: net bone loss, abnormal mineralization and collagen formation, or altered microarchitecture. The portable and low-cost ultrasound technique appears potentially useful for assessment of bone quality, and should be tested in other locations and for other bone-related disorders, to assess the feasibility of its more extensive diagnostic use in hard-to-reach rural regions.
Collapse
Key Words
- BMI, Body Mass Index
- Bone biomarker
- Bone quality
- Ethiopian Rift Valley
- F-, qFluoride
- Fluoride exposure
- IRB, Institutional Review Board
- ISE, Ion Selective Electrode
- MER, Main Ethiopian Rift
- NOAEL, No-Observed-Adverse-Effects-Level
- Quantitative ultrasound
- SOS, Speed of Sound
- Speed of sound
- TISAB, Total Ionic Strength Adjuster Buffer
- U.S. EPA, U.S. Environmental Protection Agency
- U.S. NRC, U.S. National Research Institute
- WHO, World Health Organization
- bw, body weight
- mg/L, milligram per liter
- mg/kg bw/day, milligram per kilogram body weight per day
Collapse
Affiliation(s)
- Tewodros Rango Godebo
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, New Orleans, LA 70112 USA
| | - Marc Jeuland
- Sanford School of Public Policy, Duke University, Durham, NC 27708 USA
| | - Redda Tekle-Haimanot
- Department of Neurology, School of Medicine, Addis Ababa University, Addis Ababa, Ethiopia
| | - Arti Shankar
- Department of Biostatistics and Data Science, School of Public Health and Tropical Medicine, Tulane University, New Orleans, LA 70112 USA
| | - Biniyam Alemayehu
- Department of Neurology, School of Medicine, Addis Ababa University, Addis Ababa, Ethiopia
| | - Getachew Assefa
- Department of Radiology, School of Medicine, Addis Ababa University, Addis Ababa, Ethiopia
| | - Gary Whitford
- Department of Oral Biology, College of Dental Medicine, Augusta University, Augusta, GA, USA
| | - Amy Wolfe
- Kentucky Geological Survey, University of Kentucky, KY, USA
| |
Collapse
|
27
|
Pereira D, Fernandes J, Belanger P. Ex Vivo Assessment of Cortical Bone Properties Using Low-Frequency Ultrasonic Guided Waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:910-922. [PMID: 31825866 DOI: 10.1109/tuffc.2019.2958035] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The early diagnosis of osteoporosis through bone quality assessment is a major public health challenge. Research in axial transmission using ultrasonic guided waves has shown the method to be sensitive to the geometrical and mechanical properties of the cortical layer in long bones. However, because of the asymmetric nature of cortical bone, the introduction of a more elaborate numerical model than the analytical plate and cylinder models, as well as its inversion, continues to be challenging. The aim of this article is, therefore, to implement a bone-like geometry using semianalytical finite-element (SAFE) modeling to perform the inverse characterization of ex vivo radii at low frequencies (< 60 kHz). Five cadaveric radiuses were taken from donors aged between 53 and 88 and tested using a typical axial transmission configuration at the middle of the diaphysis. The dispersion curves of the propagating modes were measured experimentally and then systematically compared with the solutions obtained with the SAFE method. For each sample, four parameters were estimated using a parameter identification procedure: 1) the bulk density; 2) the thickness; 3) the outer diameter; and 4) a shape factor (SF). The results showed a moderate agreement between the predicted bulk density and the average voxel value calculated from X-ray computed tomography images. Furthermore, a good agreement was observed between the geometrical parameters (thickness, outer diameter, and SF) and the reference images.
Collapse
|
28
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
29
|
|
30
|
Raimann A, Mehany SN, Feil P, Weber M, Pietschmann P, Boni-Mikats A, Klepochova R, Krššák M, Häusler G, Schneider J, Patsch JM, Raum K. Decreased Compressional Sound Velocity Is an Indicator for Compromised Bone Stiffness in X-Linked Hypophosphatemic Rickets (XLH). Front Endocrinol (Lausanne) 2020; 11:355. [PMID: 32582030 PMCID: PMC7296046 DOI: 10.3389/fendo.2020.00355] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 05/06/2020] [Indexed: 12/02/2022] Open
Abstract
Objectives: To assess the diagnostic potential of bidirectional axial transmission (BDAT) ultrasound, and high-resolution peripheral quantitative computed tomography (HR-pQCT) in X-linked hypophosphatemia (XLH, OMIM #307800), a rare genetic disorder of phosphate metabolism caused by mutations in the PHEX gene. Methods: BDAT bone ultrasound was performed at the non-dominant distal radius (33% relative to distal head) and the central left tibia (50%) in eight XLH patients aged between 4.2 and 20.8 years and compared to twenty-nine healthy controls aged between 5.8 and 22.4 years. In eighteen controls, only radius measurements were performed. Four patients and four controls opted to participate in HR-pQCT scanning of the ultradistal radius and tibia. Results: Bone ultrasound was feasible in patients and controls as young as 4 years of age. The velocity of the first arriving signal (νFAS) in BDAT ultrasound was significantly lower in XLH patients compared to healthy controls: In the radius, mean νFAS of XLH patients and controls was 3599 ± 106 and 3866 ± 142 m/s, respectively (-6.9%; p < 0.001). In the tibia, it was 3578 ± 129 and 3762 ± 124 m/s, respectively (-4.9%; p = 0.006). HR-pQCT showed a higher trabecular thickness in the tibia of XLH patients (+16.7%; p = 0.021). Conclusions: Quantitative bone ultrasound revealed significant differences in cortical bone quality of young XLH patients as compared to controls. Regular monitoring of XLH patients by a radiation-free technology such as BDAT might provide valuable information on bone quality and contribute to the optimization of treatment. Further studies are needed to establish this affordable and time efficient method in the XLH patients.
Collapse
Affiliation(s)
- Adalbert Raimann
- Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics, Medical University of Vienna, Vienna, Austria
| | - Sarah N. Mehany
- Division of General and Pediatric Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Patricia Feil
- Division of Pediatric Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Michael Weber
- Division of General and Pediatric Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Peter Pietschmann
- Department of Pathophysiology and Allergy Research, Medical University of Vienna, Vienna, Austria
| | - Andrea Boni-Mikats
- Division of General and Pediatric Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Radka Klepochova
- Department of Biomedical Imaging and Image-guided Therapy, The High Field MR Centre, Vienna, Austria
| | - Martin Krššák
- Department of Biomedical Imaging and Image-guided Therapy, The High Field MR Centre, Vienna, Austria
- Division of Endocrinology and Metabolism, Department of Medicine III, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging—MOLIMA, Vienna, Austria
| | - Gabriele Häusler
- Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics, Medical University of Vienna, Vienna, Austria
| | - Johannes Schneider
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, BCRT - Berlin Institute of Health Center for Regenerative Therapies, Berlin, Germany
| | - Janina M. Patsch
- Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics, Medical University of Vienna, Vienna, Austria
- Division of General and Pediatric Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- *Correspondence: Janina M. Patsch
| | - Kay Raum
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, BCRT - Berlin Institute of Health Center for Regenerative Therapies, Berlin, Germany
| |
Collapse
|
31
|
Mohanty K, Yousefian O, Karbalaeisadegh Y, Ulrich M, Grimal Q, Muller M. Artificial neural network to estimate micro-architectural properties of cortical bone using ultrasonic attenuation: A 2-D numerical study. Comput Biol Med 2019; 114:103457. [PMID: 31600691 PMCID: PMC6817400 DOI: 10.1016/j.compbiomed.2019.103457] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 09/18/2019] [Accepted: 09/19/2019] [Indexed: 01/10/2023]
Abstract
The goal of this study is to estimate micro-architectural parameters of cortical porosity such as pore diameter (φ), pore density (ρ) and porosity (ν) of cortical bone from ultrasound frequency dependent attenuation using an artificial neural network (ANN). First, heterogeneous structures with controlled pore diameters and pore densities (mono-disperse) were generated, to mimic simplified structure of cortical bone. Then, more realistic structures were obtained from high resolution CT scans of human cortical bone. 2-D finite-difference time-domain simulations were conducted to calculate the frequency-dependent attenuation in the 1-8 MHz range. An ANN was then trained with the ultrasonic attenuation at different frequencies as the input feature vectors while the output was set as the micro-architectural parameters (pore diameter, pore density and porosity). The ANN is composed of three fully connected dense layers with 24, 12 and 6 neurons, connected to the output layer. The dataset was trained over 6000 epochs with a batch size of 16. The trained ANN exhibits the ability to predict the micro-architectural parameters with high accuracy and low losses. ANN approaches could potentially be used as a tool to help inform physics-based modelling of ultrasound propagation in complex media such as cortical bone. This will lead to the solution of inverse-problems to retrieve bone micro-architectural parameters from ultrasound measurements for the non-invasive diagnosis and monitoring osteoporosis.
Collapse
Affiliation(s)
- Kaustav Mohanty
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Omid Yousefian
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Yasamin Karbalaeisadegh
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Micah Ulrich
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Quentin Grimal
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, 75006, Paris, France.
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
32
|
Caloone J, Barrere V, Sanchez M, Cambronero S, Huissoud C, Melodelima D. High-Intensity Focused Ultrasound Using a Toroidal Transducer as an Adjuvant Treatment for Placenta Accreta: A Preliminary Ex Vivo Study. Ing Rech Biomed 2019. [DOI: 10.1016/j.irbm.2019.05.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|