1
|
Vamos M, Zsigmond EJ, Biffi M, Gausz FD, Keller N, Kupo P, Szili-Torok T, Ziacchi M, Benz AP, Spittler R, Vagvolgyi A. Efficacy and safety of the subcutaneous implantable cardioverter-defibrillator in patients with and without obesity: A meta-analysis. Heart Rhythm 2024:S1547-5271(24)02902-3. [PMID: 39019386 DOI: 10.1016/j.hrthm.2024.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 06/25/2024] [Accepted: 07/11/2024] [Indexed: 07/19/2024]
Abstract
BACKGROUND The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to transvenous systems for prevention of sudden cardiac death. However, concerns have been raised regarding its efficacy and safety in obese individuals. OBJECTIVE The purpose of this study was to perform a meta-analysis to evaluate the efficacy and safety of the S-ICD in patients with obesity by assessing the relationship between body mass index (BMI) and clinical outcomes. METHODS A comprehensive search of multiple databases was conducted for English-language peer-reviewed studies reporting clinical outcomes in S-ICD recipients with (BMI ≥30 kg/m2) and without obesity (BMI <30 kg/m2). Data on preimplantation screening failure, defibrillation testing, complications, appropriate and inappropriate shocks, and survival were analyzed using standard, random-effects, meta-analytical techniques. RESULTS Twenty-nine studies involving 20,486 patients were included. There was no statistically significant difference in mean BMI values of patients with failed or successful preimplantation screening (mean difference -0.60 kg/m2; 95% confidence interval [CI] -2.06 to 0.86). Obesity was associated with higher rates of failed defibrillation testing at ≤65 J (odds ratio [OR] 2.16; 95% CI 1.39-3.35), and malpositioning/suboptimal positioning occurred more frequently in obese compared to nonobese patients (OR 3.37; 95% CI 1.76-6.44). Increased BMI as a continuous variable (per increase in 1 kg/m2 BMI) was associated with elevated defibrillation thresholds (OR 1.05; 95% CI 1.03-1.08); higher risk of complications (hazard ratio [HR] 1.04; 95% CI 1.02-1.05); a trend toward an increased number of appropriate shocks (HR 1.02; 95% CI 1.00-1.04); and no significant increase in the risk of inappropriate shocks (HR 1.01; 95% CI 0.99-1.03). CONCLUSION This meta-analysis underscores the importance of considering obesity in S-ICD implantation decisions. Although S-ICD remains effective in obese patients, attention to potential technical challenges and higher complication rates is warranted.
Collapse
Affiliation(s)
- Mate Vamos
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary.
| | - Elod-Janos Zsigmond
- Central Hospital of Northern Pest-Military Hospital, Budapest, Hungary; Doctoral School of Clinical Medicine, University of Szeged, Szeged, Hungary
| | - Mauro Biffi
- Department of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna, Bologna, Italy
| | - Flora Diana Gausz
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| | - Nora Keller
- Central Pharmacy, Albert Szent-Györgyi Medical Centre, University of Szeged, Szeged, Hungary
| | - Peter Kupo
- Heart Institute, Medical School, University of Pecs, Pecs, Hungary
| | - Tamas Szili-Torok
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| | - Matteo Ziacchi
- Department of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna, Bologna, Italy
| | - Alexander P Benz
- Department of Cardiology, University Medical Center Mainz, Johannes Gutenberg-University, Mainz, Germany; Population Health Research Institute, McMaster University, Hamilton, Canada
| | - Raphael Spittler
- Department of Cardiology, University Medical Center Mainz, Johannes Gutenberg-University, Mainz, Germany
| | - Anna Vagvolgyi
- Endocrinology and Diabetology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| |
Collapse
|
2
|
Salih A, Salam K, Goswami T, Wase A. Electromagnetic force from electric vehicles: Potential electromagnetic interference source for subcutaneous implantable defibrillator. Pacing Clin Electrophysiol 2024; 47:885-892. [PMID: 38830796 DOI: 10.1111/pace.15019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 05/03/2024] [Accepted: 05/21/2024] [Indexed: 06/05/2024]
Abstract
BACKGROUND Electromagnetic interference (EMI) encompasses electromagnetic field signals that can be detected by a device's circuitry, potentially resulting in adverse effects such as inaccurate sensing, pacing, device mode switching, and defibrillation. EMI may impact the functioning of Cardiac Implantable Electronic Devices (CIEDs) and lead to inappropriate therapy. METHOD An experimental measuring device, a loop antenna mimicking the implantable cardioverted defibrillator (ICD) antenna, was developed, and validated at the US Food and Drug Administration (FDA) and sent to Wright State University for testing. Two sets of measurements were conducted while the vehicle was connected to a 220-Volt outlet with charging at ON and OFF. Each measurement set involved three readings at various locations, with the antenna oriented in three different positions to account for diverse patient postures. The experiment utilized a Tesla Model 3 electric vehicle (EV), assessing scenarios both inside and outside the car, including the driver's seat, driver's seat floor, passenger's seat, rear seat, rear seat floor, cup holder, charging port (car), and near the charging station. RESULTS The detected voltage (max 400 to 504 millivolts) around the cup holder inside the car differed from all other measurement scenarios. CONCLUSION The investigation highlights the identification of EMI signals originating from an EV) that could potentially interrupt the functionality of a Subcutaneous Implantable Cardioverter-Defibrillator (S-ICD). These signals fell within the R-wave Spectrum of 30-300 Hz. Further in-vivo studies are essential to determine accurately the level of interference between S-ICDs and EMI from Electric Vehicles.
Collapse
Affiliation(s)
- Anmar Salih
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, USA
| | - Kamil Salam
- Wright State University Boonshoft School of Medicine, Internal Medicine, Dayton, USA
| | - Tarun Goswami
- Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, USA
| | - Abdul Wase
- Premier Cardiovascular Institute, Wright State University Boonshoft School of Medicine, Premier Health, Dayton, USA
| |
Collapse
|
3
|
Centeno M, Álvarez García-Rovés R, Pérez-Caballero R, Arenal Á, Atienza F, González-Torrecilla E, Carta A, Ríos-Muñoz GR, Medrano C, Gil-Jaurena JM, Fernández-Avilés F, Ávila P. Complications and inappropriate shocks in pediatric patients receiving a subcutaneous implantable cardioverter defibrilator. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2024; 77:362-369. [PMID: 38000625 DOI: 10.1016/j.rec.2023.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 08/08/2023] [Indexed: 11/26/2023]
Abstract
INTRODUCTION AND OBJECTIVES There is limited evidence regarding the use of subcutaneous implantable cardioverter-defibrillators (S-ICD) in pediatric patients. The aim of this study was to determine the incidence of complications in these patients at our center, according to the type of ICD and patient size. METHODS We included all patients aged<18 years who received an S-ICD since 2016 at our center. As a control group, we also included contemporary patients (since 2014) who received a transvenous ICD (TV-ICD). The primary endpoint was a composite of complications and inappropriate shocks. RESULTS A total of 26 patients received an S-ICD (median age, 14 [5-17] years; body mass index [BMI], 20.2 kg/m2). Implantation was intermuscular in 23 patients (88%) and subserratus in the remainder. Two incisions were used in 24 patients (92%). In all patients, 2 zones were programmed: a conditional zone set at 230 (220-230) bpm, and a shock zone set at 250 bpm. Nineteen patients received a TV-ICD (median age, 11 [range, 5-16] years; BMI, 19.2 kg/m2, 79% single-chamber). Survival free from the primary endpoint at 5 years was 80% in the S-ICD group and 63% in the TV-ICD group (P=.54). Survival free from inappropriate shocks was similar (85% vs 89%, P=.86), while survival free from complications was higher in the S-ICD group (96% vs 57%, cloglog P=.016). There were no therapy failures in the S-ICD group, and no increased complication rates were observed in patients with BMI ≤20 kg/m2. CONCLUSIONS With contemporary implantation techniques and programming, S-ICD is a safe and effective therapy in pediatric patients. The number of inappropriate shocks is similar to TV-ICD, with fewer short- and mid-term complications.
Collapse
Affiliation(s)
- Miriam Centeno
- Servicio de Cardiología Pediátrica, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain
| | - Reyes Álvarez García-Rovés
- Servicio de Cardiología Pediátrica, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain
| | - Ramón Pérez-Caballero
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Unidad de Cirugía Cardiaca Infantil, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Ángel Arenal
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Felipe Atienza
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Esteban González-Torrecilla
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Alejandro Carta
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Gonzalo R Ríos-Muñoz
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Departamento de Bioingeniería, Universidad Carlos III, Madrid, Spain
| | - Constancio Medrano
- Servicio de Cardiología Pediátrica, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Juan M Gil-Jaurena
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Unidad de Cirugía Cardiaca Infantil, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Francisco Fernández-Avilés
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Pablo Ávila
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain; Servicio de Cardiología, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
| |
Collapse
|
4
|
Ponnusamy SS, Ramalingam V, Mariappan S, Ganesan V, Anand V, Syed T, Murugan S, Kumar M, Vijayaraman P. Left bundle branch pacing lead for sensing ventricular arrhythmias in implantable cardioverter-defibrillator: A pilot study (LBBP-ICD study). Heart Rhythm 2024; 21:419-426. [PMID: 38142831 DOI: 10.1016/j.hrthm.2023.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 12/13/2023] [Accepted: 12/19/2023] [Indexed: 12/26/2023]
Abstract
BACKGROUND Left bundle branch pacing (LBBP) has been suggested as an alternative modality for biventricular pacing in cardiac resynchronization therapy (CRT)-eligible patients. As it provides stable R-wave sensing, LBBP has been recently used to provide sensing of ventricular arrhythmia in patients receiving implantable cardioverter-defibrillator (ICD) with CRT. OBJECTIVE The aim of this study was to analyze the long-term safety and efficacy of the LBBP lead for appropriate detection of ventricular arrhythmia and delivery of antitachycardia pacing (ATP) in patients requiring defibrillator therapy with CRT. METHODS CRT-eligible patients who underwent successful LBBP-optimized ICD and LBBP-optimized CRT with defibrillator were enrolled. The LBBP lead was connected to the right ventricular-P/S port after capping the IS-1 connector plug of the DF-1-ICD lead. LBBP-optimized ICD or LBBP-optimized CRT with defibrillator was decided on the basis of correction of conduction system disease. Documented arrhythmic episodes and therapy delivered were analyzed. RESULTS Thirty patients were enrolled. The mean age was 59.7 ± 10.5 years. LBBP resulted in an increase in left ventricular ejection fraction from 29.9% ± 4.6% to 43.9% ± 11.2% (P < .0001). During a mean follow-up of 22.9 ± 12.5 months, 254 ventricular arrhythmic events were documented. Appropriate events (n = 225 [89%]) included nonsustained ventricular tachycardia (VT) (n = 212 episodes [94%]), VT (n = 8 [3.5%]), and ventricular fibrillation (n = 5 [2.5%]). ATP efficacy in terminating VT was 75%. Eleven percent of episodes (n = 29) were inappropriately detected because of T-wave oversensing. Inappropriate therapy (ATP) was delivered for 14 episodes (5.5%). Three patients (10%) had worsening of tricuspid regurgitation. CONCLUSION Sensing from the LBBP lead for arrhythmia detection is safe as ∼90% of the episodes were detected appropriately. Future studies with a dedicated LBBP-defibrillator lead along with algorithms to avoid oversensing can help in combining defibrillation with conduction system pacing.
Collapse
Affiliation(s)
- Shunmuga Sundaram Ponnusamy
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India.
| | - Vadivelu Ramalingam
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Selvaganesh Mariappan
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Vithiya Ganesan
- Department of Microbiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Vijesh Anand
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Thabish Syed
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Senthil Murugan
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Mahesh Kumar
- Department of Cardiology, Velammal Medical College Hospital and Research Institute, Madurai, Tamil Nadu, India
| | - Pugazhendhi Vijayaraman
- Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, Pennsylvania
| |
Collapse
|
5
|
Oka S, Ishibashi K, Kato Y, Tominaga Y, Kusano K. Modified procedures of subcutaneous implantable cardioverter defibrillator implantation for a child with small body size. J Arrhythm 2024; 40:166-169. [PMID: 38333405 PMCID: PMC10848630 DOI: 10.1002/joa3.12959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 10/25/2023] [Accepted: 11/05/2023] [Indexed: 02/10/2024] Open
Abstract
Modified procedures of subcutaneous implantable cardioverter defibrillator (S-ICD) implantation for a child with a small body size are presented. This report demonstrates the feasibility of novel diagonal S-ICD lead implantation method.
Collapse
Affiliation(s)
- Satoshi Oka
- Department of Cardiovascular MedicineNational Cerebral and Cardiovascular CenterSuitaJapan
| | - Kohei Ishibashi
- Department of Cardiovascular MedicineNational Cerebral and Cardiovascular CenterSuitaJapan
| | - Yoshiaki Kato
- Department of Pediatric CardiologyNational Cerebral and Cardiovascular CenterSuitaJapan
| | - Yuji Tominaga
- Department of Pediatric Cardiovascular SurgeryNational Cerebral and Cardiovascular CenterSuitaJapan
| | - Kengo Kusano
- Department of Cardiovascular MedicineNational Cerebral and Cardiovascular CenterSuitaJapan
| |
Collapse
|
6
|
Okazaki M, Sahashi Y, Nagase T, Inoue K, Sekiguchi Y, Nitta J, Shinoda S, Shimizu S, Kuroki M, Isobe M, Mihara T. Inappropriate shock incidence in patients with subcutaneous implantable cardioverter-defibrillators with concomitant cardiac implantable electronic devices: A single-center cohort study. Pacing Clin Electrophysiol 2024; 47:131-138. [PMID: 38010718 DOI: 10.1111/pace.14887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/08/2023] [Accepted: 11/15/2023] [Indexed: 11/29/2023]
Abstract
BACKGROUND Subcutaneous implantable cardioverter defibrillators (S-ICDs) are occasionally used in combination with other cardiac implantable electronic devices (CIEDs). However, whether the incidence of inappropriate shock increases in patients with S-ICDs and concomitant CIEDs remains unclear. This study aimed to investigate the association between the concomitant use of CIEDs and the incidence of inappropriate shock in patients with current-generation S-ICDs. METHODS A total of 127 consecutive patients received an S-ICD. Patients were assigned to two groups depending on concomitant use of CIEDs at the time of S-ICD implantation: patients without other CIEDs (non-combined group, 106 patients) and patients with other CIEDs (combined group, 21 patients). CIEDs included pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy pacemakers, and cardiac resynchronization therapy defibrillators. The primary outcome was inappropriate shock, defined as a shock other than ventricular arrhythmia. Hazard ratios and 95% confidence intervals were calculated using a time-varying Cox proportional hazards model which was adjusted for age because age differed between the groups and could be a confounder. RESULTS During a median follow-up period of 2.2 years (interquartile range, 1.0-3.4 years), inappropriate shock events occurred in 17 (16%) and five (19%) patients of the non-combined and combined groups, respectively. While the age-adjusted hazard ratio for inappropriate shock was 24% higher in the combined than in the non-combined group (hazard ratio = 1.24, 95% confidence interval, 0.39-3.97), this difference was insignificant (p = .71). CONCLUSION The incidence of inappropriate shock did not differ between patients with and without concomitant use of CIEDs, suggesting that S-ICDs could potentially be combined with other CIEDs without increasing the number of inappropriate shocks. Further studies are warranted to confirm the safety and feasibility of concomitant use of S-ICDs and CIEDs.
Collapse
Affiliation(s)
- Makiko Okazaki
- Department of Clinical Engineering, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
- Department of Health Data Science, Yokohama City University Graduate School of Data Science, Yokohama-shi, Kanagawa, Japan
| | - Yuki Sahashi
- Department of Cardiology, Gifu University Graduate School of Medicine, Gifu-shi, Japan
| | - Takahiko Nagase
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Kanki Inoue
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Yukio Sekiguchi
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Junichi Nitta
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Satoru Shinoda
- Department of Biostatistics, School of Medicine, Yokohama City University, Yokohama-shi, Kanagawa, Japan
| | - Sayuri Shimizu
- Department of Health Data Science, Yokohama City University Graduate School of Data Science, Yokohama-shi, Kanagawa, Japan
| | - Makoto Kuroki
- Department of Health Data Science, Yokohama City University Graduate School of Data Science, Yokohama-shi, Kanagawa, Japan
| | | | - Takahiro Mihara
- Department of Health Data Science, Yokohama City University Graduate School of Data Science, Yokohama-shi, Kanagawa, Japan
| |
Collapse
|
7
|
Kohli U, von Alvensleben J, Srinivasan C. Subcutaneous Implantable Cardioverter Defibrillators in Pediatrics and Congenital Heart Disease. Card Electrophysiol Clin 2023; 15:e1-e16. [PMID: 38030336 DOI: 10.1016/j.ccep.2023.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
Subcutaneous implantable cardioverter defibrillators (S-ICDs) are being used with increased frequency in children and patients with congenital heart disease. Vascular access complexities, intracardiac shunts, and specific anatomies make these devices particularly appealing for some of these patients. Alternative screening, implantation, and programming techniques should be considered based on patient size, body habitus, anatomy, procedural history, and preference. Appropriate and inappropriate shock rates are generally comparable to those seen with transvenous devices. Complications such as infection can occur, although their severity is likely to be less than that seen with transvenous devices. Technical advances are likely to further broaden S-ICD applicability.
Collapse
Affiliation(s)
- Utkarsh Kohli
- Division of Pediatric Cardiology, Department of Pediatrics, West Virginia University School of Medicine and West Virginia University Children's Heart Center, 64 Medical Center Drive, Robert C. Byrd Health Science Center, PO Box 9214, Morgantown, WV 26506-9214, USA.
| | - Johannes von Alvensleben
- Children's Hospital Colorado, University of Colorado School of Medicine, 13123 East 16th Avenue, Aurora, CO 80045 720-777-1234, USA
| | - Chandra Srinivasan
- The Children's Hospital of Philadelphia; University of Perelman School of Medicine, 3401 Civic Center Boulevard, Philadelphia, PA 19104, USA
| |
Collapse
|
8
|
Ghanta SN, Alotaibi B, Paydak H, Mounsey JP, Vallurupalli S, Devabhaktuni S. Inappropriate Subcutaneous Implantable Cardioverter-defibrillator Shocks-A Rare Case of Triple Counting. J Innov Card Rhythm Manag 2023; 14:5670-5674. [PMID: 38155720 PMCID: PMC10752427 DOI: 10.19102/icrm.2023.14121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 07/20/2023] [Indexed: 12/30/2023] Open
Abstract
Sudden cardiac death (SCD) caused by ventricular tachyarrhythmias is a significant contributor to cardiovascular deaths worldwide. Implantable cardioverter-defibrillators (ICDs) have shown efficacy in preventing and reducing mortality from SCD, but traditional transvenous ICDs have inherent challenges and drawbacks, such as lead fractures, lead-associated endocarditis, and lead failure. To address these issues, subcutaneous ICDs (S-ICDs) have been developed. S-ICDs lack pacing capacity but are a valid alternative for patients at high risk for infection or with difficult venous access. Pre-implantation screening can help prevent inappropriate device shocks. We present a case in which a patient received inappropriate S-ICD therapy, which was attributed to the triple counting of P-, R-, and T-waves in a patient with sinus rhythm. This is an unusual occurrence, and, to the best of our knowledge, there are only a limited number of case reports documenting inappropriate shocks due to the oversensing of P-waves and T-waves.
Collapse
Affiliation(s)
- Sai Nikhila Ghanta
- Department of Internal Medicine, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Bader Alotaibi
- Department of Medicine, Division of Cardiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Hakan Paydak
- Department of Medicine, Division of Cardiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - J. Paul Mounsey
- Department of Medicine, Division of Cardiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Srikanth Vallurupalli
- Department of Medicine, Division of Cardiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Subodh Devabhaktuni
- Department of Medicine, Division of Cardiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| |
Collapse
|
9
|
Zhang L, Li X, Liang Y, Wang J, Li M, Pan L, Chen X, Qin S, Bai J, Wang W, Su Y, Ge J. Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience. Herz 2023; 48:462-469. [PMID: 37540305 DOI: 10.1007/s00059-023-05192-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 05/26/2023] [Accepted: 05/27/2023] [Indexed: 08/05/2023]
Abstract
BACKGROUND Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future. METHODS Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed. RESULTS In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%. CONCLUSION Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.
Collapse
Affiliation(s)
- Lei Zhang
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiao Li
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Yixiu Liang
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Jingfeng Wang
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Minghui Li
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Lei Pan
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xueying Chen
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Shengmei Qin
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Jin Bai
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Wei Wang
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Yangang Su
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China.
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China.
| | - Junbo Ge
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Xietu Road, 1069, Shanghai, China.
- National Clinical Research Center for Interventional Medicine, Shanghai Clinical Research Center for Interventional Medicine, Shanghai, China.
| |
Collapse
|
10
|
Strik M, Ploux S, Eschalier R, Mondoly P, Fontagne L, Ramirez FD, Haïssaguerre M, Bordachar P. T-Wave Oversensing with Contemporary Implantable Cardioverter-Defibrillators. J Cardiovasc Dev Dis 2023; 10:430. [PMID: 37887877 PMCID: PMC10607450 DOI: 10.3390/jcdd10100430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/27/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
BACKGROUND Implantable cardioverter-defibrillators (ICDs) need to reliably detect ventricular tachycardia (VT) and ventricular fibrillation (VF) while avoiding T-wave oversensing (TWOS), which is associated with a risk of inappropriate therapies. The incidence of TWOS with endovascular ICDs appears to differ between manufacturers. OBJECTIVES We aimed to evaluate the incidence and clinical consequences of TWOS with contemporary Medtronic and Boston Scientific ICDs. METHODS Consecutive patients implanted with a recent Medtronic or Boston Scientific ICD and remotely monitored at three French centers were included. All transmitted EGMs labelled as VF, VT, non-sustained VT (NSVT), or ventricular oversensing (Medtronic) were screened for TWOS. RESULTS Among 7589 transmitted episodes from 674 patients with a Boston Scientific ICD, we did not identify a single case of TWOS. Among 16,790 transmitted episodes from 1733 patients with a Medtronic ICD, we identified 60 patients (3.4%) with at least one episode of TWOS. In 46 patients, TWOS was intermittent (NSVT episodes). In the remaining 14 patients, TWOS resulted in 60 sustained episodes (completed counters). No inappropriate therapies were delivered in 12 of these patients because no therapies were programmed (in monitor zones, 11 episodes) or because therapies were inhibited by the morphology discriminator (Wavelet, 19 episodes) or by the anti-TWOS algorithm (26 episodes). Two patients received inappropriate therapies due to TWOS (0.1% of patients with Medtronic ICDs). CONCLUSION On review of 24,379 transmitted episodes from 2407 patients with endovascular ICDs, we found no case of TWOS with Boston Scientific devices, whereas TWOS was not uncommon with Medtronic devices. However, the risk of inappropriate therapy with Medtronic ICDs was very low (0.1%) due to the often intermittent nature of this phenomenon, the morphology discriminator, and the anti-TWOS algorithm.
Collapse
Affiliation(s)
- Marc Strik
- Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Bordeaux, France
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Université de Bordeaux, F-33600 Bordeaux, France
| | - Sylvain Ploux
- Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Bordeaux, France
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Université de Bordeaux, F-33600 Bordeaux, France
| | - Romain Eschalier
- Department of Cardiology, University Hospital Clermont-Ferrand, 63000 Clermont-Ferrand, France
| | - Pierre Mondoly
- Department of Cardiology, University Hospital Rangueil, 31400 Toulouse, France
| | - Leslie Fontagne
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Université de Bordeaux, F-33600 Bordeaux, France
| | - F. Daniel Ramirez
- Division of Cardiology, University of Ottawa Heart Institute, Ottawa, ON K1Y 4W7, Canada
| | - Michel Haïssaguerre
- Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Bordeaux, France
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Université de Bordeaux, F-33600 Bordeaux, France
| | - Pierre Bordachar
- Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Bordeaux, France
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Université de Bordeaux, F-33600 Bordeaux, France
| |
Collapse
|
11
|
Francia P, Ziacchi M, Adduci C, Ammendola E, Pieragnoli P, De Filippo P, Rapacciuolo A, Rella V, Migliore F, Viani S, Musumeci MB, Biagini E, Lovecchio M, Baldini R, Falasconi G, Autore C, Biffi M, Cecchi F. Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator. Europace 2023; 25:euad270. [PMID: 37724686 PMCID: PMC10507661 DOI: 10.1093/europace/euad270] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/09/2023] [Indexed: 09/21/2023] Open
Abstract
AIMS The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
Collapse
Affiliation(s)
- Pietro Francia
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Matteo Ziacchi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Carmen Adduci
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Ernesto Ammendola
- Department of Translational Medical Sciences, University of Campania ‘Luigi Vanvitelli’, Monaldi Hospital, Naples, Italy
| | - Paolo Pieragnoli
- Careggi University Hospital, University of Florence, Florence, Italy
| | | | - Antonio Rapacciuolo
- Department of Advanced Biomedical Sciences, Federico II University, Naples, Italy
| | - Valeria Rella
- Department of Cardiovascular, Neural and Metabolic Sciences, IRCCS, Istituto Auxologico Italiano, San Luca Hospital, Milan, Italy
| | - Federico Migliore
- Department of Cardiac, Thoracic Vascular Sciences and Public Health University of Padova, Padova, Italy
| | - Stefano Viani
- Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
| | - Maria Beatrice Musumeci
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Elena Biagini
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | | | - Rossella Baldini
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Giulio Falasconi
- Campus Clínic, University of Barcelona, Barcelona, Spain
- IRCCS Humanitas Research Hospital, Milan, Italy
| | - Camillo Autore
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Mauro Biffi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Franco Cecchi
- Careggi University Hospital, University of Florence, Florence, Italy
- Department of Cardiovascular, Neural and Metabolic Sciences, IRCCS, Istituto Auxologico Italiano, San Luca Hospital, Milan, Italy
| |
Collapse
|
12
|
Fukunaga H, Inoue K, Sekiguchi Y, Nitta J, Isobe M. Successful repositioning of the subcutaneous implantable cardioverter-defibrillator lead to avoid inappropriate shock. J Arrhythm 2023; 39:74-77. [PMID: 36733326 PMCID: PMC9885306 DOI: 10.1002/joa3.12805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 12/10/2022] [Accepted: 12/22/2022] [Indexed: 01/05/2023] Open
Affiliation(s)
| | - Kanki Inoue
- Department of CardiologySakakibara Heart InstituteTokyoJapan
| | - Yukio Sekiguchi
- Department of CardiologySakakibara Heart InstituteTokyoJapan
| | - Junichi Nitta
- Department of CardiologySakakibara Heart InstituteTokyoJapan
| | - Mitsuaki Isobe
- Department of CardiologySakakibara Heart InstituteTokyoJapan
| |
Collapse
|
13
|
Schiavone M, Gasperetti A, Laredo M, Breitenstein A, Vogler J, Palmisano P, Gulletta S, Pignalberi C, Lavalle C, Pisanò E, Ricciardi D, Curnis A, Dello Russo A, Tondo C, Badenco N, Di Biase L, Kuschyk J, Biffi M, Tilz R, Forleo GB, Arosio R, Ruggiero D, Viecca M, Ziacchi M, Diemberger I, Angeletti A, Fierro N, Della Bella P, Mitacchione G, Compagnucci P, Casella M, Santini L, Piro A, Picarelli F, Bressi E, Calò L, Montemerlo E, Rovaris G, De Bonis S, Bisignani A, Bisignani G, Russo G, Guarracini F, Vitali F, Bertini M, Fink T, Fastenrath F, Kaiser L, Hakmi S, Waintraub X, Gandjbakhch E, Saguner A. Inappropriate Shock Rates and Long-Term Complications due to Subcutaneous Implantable Cardioverter Defibrillators in Patients With and Without Heart Failure: Results From a Multicenter, International Registry. Circ Arrhythm Electrophysiol 2023; 16:e011404. [PMID: 36595631 DOI: 10.1161/circep.122.011404] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Marco Schiavone
- Luigi Sacco University Hospital, Milan (M.S., A.G., G.B.F.).,Department of Systems Medicine, University of Rome Tor Vergata, Italy (M.S.)
| | - Alessio Gasperetti
- Luigi Sacco University Hospital, Milan (M.S., A.G., G.B.F.).,Department of Cardiology, Johns Hopkins University, Baltimore, MD (A.G., N.B.)
| | - Mikael Laredo
- APHP, Hôpital Pitié Salpêtrière, Paris, France (M.L.)
| | | | - Julia Vogler
- Department of Elctrophysiology, Herzzentrum Lubeck, Germany (J.V., R.T.)
| | - Pietro Palmisano
- Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy (P.P.)
| | - Simone Gulletta
- Arrhythmology & Electrophysiology Unit, San Raffaele Hospital, IRCCS, Milan (S.G.)
| | | | | | - Ennio Pisanò
- U.O.S.V.D. Cardiac Electrophysiology - "V. Fazzi" Hospital, Lecce (E.P.)
| | | | | | - Antonio Dello Russo
- Cardiology and Arrhythmology Clinic, University Hospital "Umberto I-Salesi-Lancisi," Ancona (A.D.R.)
| | - Claudio Tondo
- Heart Rhythm Centre, Monzino Cardiology Centre, IRCCS, Milan, Italy (C.T.)
| | - Nicolas Badenco
- Department of Cardiology, Johns Hopkins University, Baltimore, MD (A.G., N.B.)
| | - Luigi Di Biase
- Cardiac Arrhythmia Center, Division of Cardiology at Montefiore-Einstein Center, Bronx, NY (L.D.B.)
| | - Jürgen Kuschyk
- Cardiology Unit, University Medical Center Mannheim, Germany (J.K.)
| | - Mauro Biffi
- Cardiology, IRCCS, Department of Experimental, Diagnostic & Specialty Medicine, Sant'Orsola Hospital, University of Bologna, Bologna, Italy (M.B.)
| | - Roland Tilz
- Deutsches Zentrum für Herz-Kreislauf-Forschung (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany (R.T.)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Romero J, Rodriguez-Taveras J, Diaz JC, Lorente-Ros M, Braunstein ED, Alviz I, Parides M, Haroun MW, Papa L, Dave K, Rodriguez D, Krishnan S, Toquica C, Velasco A, Gabr M, Natale A, Di Biase L. Tumescent local anesthesia versus general anesthesia for subcutaneous implantable cardioverter-defibrillator implantation: A cost-effectiveness analysis. Heart Rhythm 2022; 20:522-529. [PMID: 36563830 DOI: 10.1016/j.hrthm.2022.12.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 12/05/2022] [Accepted: 12/09/2022] [Indexed: 12/25/2022]
Abstract
BACKGROUND General anesthesia (GA) is the standard anesthetic approach for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. Nonetheless, GA is expensive and can be associated with adverse events. Tumescent local anesthesia (TLA) has been shown to reduce in-room and procedural times and to decrease post-procedural pain, all of which could result in a reduction in procedure-related costs. OBJECTIVE The purpose of this study is to compare the cost-effectiveness of GA and TLA in patients undergoing S-ICD implantation. METHODS The present study is a prospective, nonrandomized, controlled study of patients who underwent S-ICD implantation between 2019 and 2022. Patients were allocated to either the TLA or the GA group. We performed a cost analysis for each intervention. As an effectiveness measure, the 0-10 point Numeric Pain Rating Scale at 1, 12, and 24 hours post-implantation was analyzed and compared between the groups. A score of 0 was considered no pain; 1-5, mild pain; 6-7, moderate pain; and 8-10, severe pain. Cost-effectiveness was calculated using incremental cost-effectiveness ratios. RESULTS Seventy patients underwent successful S-ICD implantation. The total cost of the electrophysiology laboratory was higher in the GA group than in the TLA group (median ± interquartile range US$55,824 ± US$29,411 vs US$37,222 ± US$24,293; P < .001), with a net saving of $20,821 when compared with GA for each S-ICD implantation. There was a significant decrease in post-procedural pain scores in the TLA group when compared with the GA group (repeated measures analysis of variance, P = .009; median ± interquartile range 0 ± 3 vs 0 ± 5 at 1 hour, P = .058; 3 ± 4 vs 6 ± 8 at 12 hours, P = .030; 0 ± 4 vs 2 ± 6 at 24 hours, P = .040). CONCLUSION TLA is a more cost-effective alternative to GA for S-ICD implantation, with both direct and indirect cost reductions. Importantly, these reduced costs are associated with reduced postprocedural pain.
Collapse
Affiliation(s)
- Jorge Romero
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Joan Rodriguez-Taveras
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Juan Carlos Diaz
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Marta Lorente-Ros
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Eric D Braunstein
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Isabella Alviz
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Michael Parides
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Magued W Haroun
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Lauren Papa
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Kartikeya Dave
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Daniel Rodriguez
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Suraj Krishnan
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Christian Toquica
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Alejandro Velasco
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Mohamed Gabr
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York
| | - Andrea Natale
- Texas Cardiac Arrhythmia Institute at St. David's Medical Center, Austin, Texas
| | - Luigi Di Biase
- Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York.
| |
Collapse
|
15
|
Gold MR, Aasbo JD, Weiss R, Burke MC, Gleva MJ, Knight BP, Miller MA, Schuger CD, Carter N, Leigh J, Brisben AJ, El-Chami MF. Infection in patients with subcutaneous implantable cardioverter-defibrillator: Results of the S-ICD Post Approval Study. Heart Rhythm 2022; 19:1993-2001. [PMID: 35944889 DOI: 10.1016/j.hrthm.2022.07.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/24/2022] [Accepted: 07/28/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Early subcutaneous implantable cardioverter-defibrillator (S-ICD) studies included atypical cohorts of patients who were younger with fewer comorbidities. Recent S-ICD studies included patient populations with more comorbidities. OBJECTIVES The goals of this study were to determine the incidence and predictors of S-ICD-related infection over a 3-year follow-up period and to use these results to develop an infection risk score. METHODS The S-ICD Post Approval Study is a US prospective registry of 1637 patients. Baseline demographic characteristics and outcomes with 3-year postimplantation follow-up were compared between patients with and without device-related infection. A risk score was derived from multivariable proportional hazards analysis of 22 variables. RESULTS Infection was observed in 55 patients (3.3%), with 69% of infections occurring within 90 days and a vast majority (92.7%) within 1 year of implantation. Late infections more likely involved device erosion; no infections occurred after year 2. The annual mortality rate postinfection was 0.6%/y. No lead extraction complications or bacteremia related to infection were observed. An infection risk score was created with diabetes, age, prior transvenous ICD implant, and ejection fraction as predictors. Patients with a risk score of ≥3 had an 8.8 hazard ratio (95% confidence interval 2.8-16.3) of infection compared with a 0 risk score. CONCLUSION Infection rates in the S-ICD Post Approval Study were similar to other S-ICD populations and not associated with systemic blood-borne infections. Late infection (>1 year) is uncommon and associated with system erosion. A high-risk infection cohort can be identified that may facilitate preventive measures.
Collapse
Affiliation(s)
- Michael R Gold
- Department of Medicine, Medical University of South Carolina, Charleston, South Carolina.
| | - Johan D Aasbo
- Department of Cardiac Electrophysiology, Lexington Cardiology/Baptist Health Medical Group, Lexington, Kentucky
| | - Raul Weiss
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio
| | | | - Marye J Gleva
- Washington University School of Medicine, Saint Louis, Missouri
| | - Bradley P Knight
- Center for Heart Rhythm Disorders Bluhm Cardiovascular Institute, Northwestern Memorial Hospital, Chicago, Illinois
| | - Marc A Miller
- Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, New York
| | | | - Nathan Carter
- Boston Scientific Corporation, Saint Paul, Minnesota
| | - Jill Leigh
- Boston Scientific Corporation, Saint Paul, Minnesota
| | - Amy J Brisben
- Boston Scientific Corporation, Saint Paul, Minnesota
| | | |
Collapse
|
16
|
Gasperetti A, Schiavone M, Vogler J, Laredo M, Fastenrath F, Palmisano P, Ziacchi M, Angeletti A, Mitacchione G, Kaiser L, Compagnucci P, Breitenstein A, Arosio R, Vitali F, De Bonis S, Picarelli F, Casella M, Santini L, Pignalberi C, Lavalle C, Pisanò E, Ricciardi D, Calò L, Curnis A, Bertini M, Gulletta S, Dello Russo A, Badenco N, Tondo C, Kuschyk J, Tilz R, Forleo GB, Biffi M. The need for a subsequent transvenous system in patients implanted with subcutaneous implantable cardioverter-defibrillator. Heart Rhythm 2022; 19:1958-1964. [PMID: 35781042 DOI: 10.1016/j.hrthm.2022.06.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/21/2022] [Accepted: 06/24/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited. OBJECTIVE The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors. METHODS All patients implanted with an S-ICD were enrolled from the multicenter, real-world iSUSI (International SUbcutaneouS Implantable cardioverter defibrillator) Registry. The need for a TV device and its clinical reason, and appropriate and inappropriate device therapies were assessed. Logistic regression with Firth penalization was used to assess the association between baseline and procedural characteristics and the overall need for a subsequent TV device. RESULTS A total of 1509 patients were enrolled (age 50.8 ± 15.8 years; 76.9% male; 32.0% ischemic; left ventricular ejection fraction 38% [30%-60%]). Over 26.5 [13.4-42.9] months, 155 (10.3%) and 144 (9.3%) patients experienced appropriate and inappropriate device therapies, respectively. Forty-one patients (2.7%) required a TV device (13 bradycardia; 10 need for CRT; 10 inappropriate shocks). Body mass index (BMI) >30 kg/m2 and chronic kidney disease (CKD) were associated with need for a TV device (odds ratio [OR] 2.57 [1.37-4.81], P = .003; and OR 2.67 [1.29-5.54], P = .008, respectively). CONCLUSION A low rate (2.7%) of conversion from S-ICD to a TV device was observed at follow-up, with need for antibradycardia pacing, ATP, or CRT being the main reasons. BMI >30 kg/m2 and CKD predicted all-cause need for a TV device.
Collapse
Affiliation(s)
- Alessio Gasperetti
- Cardiology Unit, Luigi Sacco University Hospital, Milan, Italy; Università degli Studi di Milano, Milan, Italy; Johns Hopkins University, Baltimore, Maryland; Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
| | | | - Julia Vogler
- Department of Rhythmology, Herzzentrum Lubeck, Lubeck, Germany
| | | | - Fabian Fastenrath
- Cardiology Unit, University Medical Centre Mannheim, Manheim, Germany
| | | | - Matteo Ziacchi
- Cardiology Unit, IRCCS, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola Hospital, University of Bologna, Bologna, Italy
| | - Andrea Angeletti
- Cardiology Unit, IRCCS, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola Hospital, University of Bologna, Bologna, Italy
| | - Gianfranco Mitacchione
- Cardiology Unit, Luigi Sacco University Hospital, Milan, Italy; Cardiology Unit, Spedali Civili Brescia, Brescia, Italy
| | | | - Paolo Compagnucci
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy; Cardiology and Arrhythmology Clinic, University Hospital Ospedali Riuniti, Ancona, Italy
| | | | | | - Francesco Vitali
- Cardiological Center, S. Anna University Hospital, Ferrara, Italy
| | - Silvana De Bonis
- Department of Cardiology, Castrovillari Hospital, Cosenza, Italy
| | | | - Michela Casella
- Cardiology and Arrhythmology Clinic, University Hospital Ospedali Riuniti, Ancona, Italy
| | - Luca Santini
- Cardiology Unit, Ospedale G.B. Grassi, Ostia, Italy
| | | | | | - Ennio Pisanò
- Cardiac Electrophysiology Unit, Vito Fazzi Hospital, Lecce, Italy
| | | | | | | | - Matteo Bertini
- Cardiological Center, S. Anna University Hospital, Ferrara, Italy
| | - Simone Gulletta
- Arrhythmology and Electrophysiology Unit, San Raffaele Hospital, IRCCS, Milan, Italy
| | - Antonio Dello Russo
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy; Cardiology and Arrhythmology Clinic, University Hospital Ospedali Riuniti, Ancona, Italy
| | | | - Claudio Tondo
- Heart Rhythm Center, Monzino Cardiology Center, IRCCS, Milan, Italy
| | - Jürgen Kuschyk
- Cardiology Unit, University Medical Centre Mannheim, Manheim, Germany
| | - Roland Tilz
- Department of Rhythmology, Herzzentrum Lubeck, Lubeck, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | | | - Mauro Biffi
- Cardiology Unit, IRCCS, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola Hospital, University of Bologna, Bologna, Italy
| |
Collapse
|
17
|
Sugawara M, Takatsugu K, Kondo Y, Watanabe M, Matsumiya G, Kobayashi Y. Subcutaneous implantable cardioverter-defibrillator implantation in a patient with an axillary bifemoral bypass and past sternectomy. HeartRhythm Case Rep 2022; 9:80-83. [PMID: 36860744 PMCID: PMC9968905 DOI: 10.1016/j.hrcr.2022.10.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Affiliation(s)
- Masafumi Sugawara
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan,Address reprint requests and correspondence: Dr Masafumi Sugawara, Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan.
| | - Kajiyama Takatsugu
- Department of Advanced Cardiorhythm Therapeutics, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Yusuke Kondo
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Michiko Watanabe
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Goro Matsumiya
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Yoshio Kobayashi
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| |
Collapse
|
18
|
The subcutaneous implantable cardioverter-defibrillator should be considered for all patients with an implantable cardioverter-defibrillator indication. Heart Rhythm O2 2022; 3:589-596. [PMID: 36340497 PMCID: PMC9626906 DOI: 10.1016/j.hroo.2022.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
|
19
|
Wieniawski P, Buczyński M, Grabowski M, Winter J, Werner B. Subcutaneous Implantable Cardioverter Defibrillators for the Prevention of Sudden Cardiac Death: Pediatric Single-Center Experience. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11661. [PMID: 36141934 PMCID: PMC9517274 DOI: 10.3390/ijerph191811661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/08/2022] [Accepted: 09/13/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the transvenous ICD, to prevent lead-related complications associated with the latter. The absence of intravascular or intracardiac components offers potential advantages to pediatric patients. AIMS The aim of the study is to present an overview of our experience with S-ICDs in the pediatric center that, currently, has performed the largest number of implantations in children in Poland. METHODS Retrospective analysis of data from medical history, qualification, implantation procedure, and S-ICD post-implantation observations in 11 pediatric patients were performed. RESULTS S-ICDs were implanted in 11 patients, 8 boys and 3 girls, aged 12-17 years. The S-ICD was implanted for primary prevention in seven patients: four with hypertrophic cardiomyopathy (HCM), two with dilated cardiomyopathy (DCM), and one with arrhythmogenic right ventricular cardiomyopathy (ARVC). It was implanted for secondary prevention in four patients: two with sudden cardiac arrest (SCA) in the course of idiopathic ventricular fibrillation (IVF), one with long QT syndrome (LQTS) after probable SCA, and one with Brugada syndrome after SCA. In all patients, the device was implanted intramuscularly. One patient did not have a defibrillation test performed due to the presence of an intracardiac thrombus. In one patient, during screening, it was decided to implant an electrode on the right side of the sternum. There were no early or late complications with any of the procedures. So far, no inadequate discharges have been observed. CONCLUSIONS Our results prove the efficacy of the S-ICD treatment option along with technically simple surgery, which supports its further and more widespread application in children.
Collapse
Affiliation(s)
- Piotr Wieniawski
- Department of Paediatric Cardiology and General Paediatrics, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Michał Buczyński
- Department of Cardiac and General Paediatric Surgery, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Marcin Grabowski
- 1st Department of Cardiology, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Joachim Winter
- Division of Cardiac Surgery, University of Düsseldorf, 40225 Düsseldorf, Germany
| | - Bożena Werner
- Department of Paediatric Cardiology and General Paediatrics, Medical University of Warsaw, 02-091 Warsaw, Poland
| |
Collapse
|
20
|
Leo M, Sharp AJ, Gala ABE, Pope MTB, Betts TR. Transvenous or subcutaneous implantable cardioverter defibrillator: a review to aid decision-making. J Interv Card Electrophysiol 2022:10.1007/s10840-022-01299-6. [PMID: 35835888 DOI: 10.1007/s10840-022-01299-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 07/06/2022] [Indexed: 01/08/2023]
Abstract
The implantable cardioverter-defibrillator (ICD) is a proven treatment for preventing sudden cardiac death. Transvenous leads are associated with significant mortality and morbidity, and the subcutaneous ICD (S-ICD) addresses this. However, it is not without limitations, in particular the absence of anti-tachycardia pacing. The decision of which device is most suitable for an individual patient is often complex. Here, we review the relative merits and weaknesses of both the transvenous and S-ICD. We summarise the available evidence for each device in particular patient cohorts, namely: ischaemic and non-ischaemic cardiomyopathy, idiopathic ventricular fibrillation, Brugada syndrome, long QT syndrome, arrhythmogenic right ventricular cardiomyopathy, and hypertrophic cardiomyopathy.
Collapse
Affiliation(s)
- Milena Leo
- Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Alexander J Sharp
- Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
| | - Andre Briosa E Gala
- Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Michael T B Pope
- Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Timothy R Betts
- Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| |
Collapse
|
21
|
Hakamata T, Otsuki S, Izumi D, Sakaguchi Y, Suzuki N, Ikami Y, Hasegawa Y, Yagihara N, Iijima K, Chinushi M, Koichi F, Inomata T. Clinical impact of ECG change on oversensing of subcutaneous implantable cardioverter-defibrillators. Heart Rhythm 2022; 19:1704-1711. [PMID: 35688344 DOI: 10.1016/j.hrthm.2022.05.037] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 05/01/2022] [Accepted: 05/13/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND Inappropriate shocks delivered from subcutaneous implantable cardioverter-defibrillators (S-ICD) are most frequently caused by cardiac oversensing. However, the predictors for oversensing of S-ICD remain unclear. OBJECTIVE We aimed to investigate the predictors for oversensing of S-ICD, especially clinical impact of ECG change. METHODS We retrospectively enrolled 99 consecutive patients who underwent S-ICD implantation between 2013 and 2021. Oversensing events were defined as inappropriate charge of the capacitors induced by cardiac or noncardiac signals other than tachycardia. RESULTS During a median 34 month (IQR 20-50 months) of the follow-up period, 11 of the 99 patients experienced 34 oversensing events and 4 patients received inappropriate shocks during their events. Six patients exhibited ECG changes (bundle branch block, 3; ventricular pacing, 1; inverted T wave, 1; poor R progression, 1) during follow-up period. Oversensing events were observed in four of the six patients with ECG changes (67%), and three patients underwent S-ICD removal because of inevitable shock. Contrastingly, among the remaining patients without ECG change, all 7 patients who experienced oversensing events could continue using S-ICD with reprogramming sensing vector and/or restriction of excessive exercise. Logistic regression analysis showed lower voltage of Sokolow-Lyon ECG (V1S+V5R) was the predictor of oversensing event among the patients without ECG change. When the cut off value was 2.1mV, the sensitivity, specificity, positive predictive value, and negative predictive value were 85.7%, 62.7%, 15.7%, and 98.1%, respectively. CONCLUSION Unavoidable oversensing resulting in S-ICD removal is caused by ECG changes. Oversensing in patients without ECG change can be managed.
Collapse
Affiliation(s)
- Takahiro Hakamata
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Sou Otsuki
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
| | - Daisuke Izumi
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Yuta Sakaguchi
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Naomasa Suzuki
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Yasuhiro Ikami
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Yuki Hasegawa
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Nobue Yagihara
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Kenichi Iijima
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Masaomi Chinushi
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | | | - Takayuki Inomata
- Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| |
Collapse
|
22
|
Fong KY, Ng CJR, Wang Y, Yeo C, Tan VH. Subcutaneous Versus Transvenous Implantable Defibrillator Therapy: A Systematic Review and Meta-Analysis of Randomized Trials and Propensity Score-Matched Studies. J Am Heart Assoc 2022; 11:e024756. [PMID: 35656975 PMCID: PMC9238723 DOI: 10.1161/jaha.121.024756] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Subcutaneous implantable cardioverter‐defibrillators (S‐ICDs) have been of great interest as an alternative to transvenous implantable cardioverter‐defibrillators (TV‐ICDs). No meta‐analyses synthesizing data from high‐quality studies have yet been published. Methods and Results An electronic literature search was conducted to retrieve randomized controlled trials or propensity score–matched studies comparing S‐ICD against TV‐ICD in patients with an implantable cardioverter‐defibrillator indication. The primary outcomes were device‐related complications and lead‐related complications. Secondary outcomes were inappropriate shocks, appropriate shock, all‐cause mortality, and infection. All outcomes were pooled under random‐effects meta‐analyses and reported as risk ratios (RRs) and 95% CIs. Kaplan–Meier curves of device‐related complications were digitized to retrieve individual patient data and pooled under a 1‐stage meta‐analysis using Cox models to determine hazard ratios (HRs) of patients undergoing S‐ICD versus TV‐ICD. A total of 5 studies (2387 patients) were retrieved. S‐ICD had a similar rate of device‐related complications compared with TV‐ICD (RR, 0.59 [95% CI, 0.33–1.04]; P=0.070), but a significantly lower lead‐related complication rate (RR, 0.14 [95% CI, 0.07–0.29]; P<0.0001). The individual patient data–based 1‐stage stratified Cox model for device‐related complications across 4 studies yielded no significant difference (shared‐frailty HR, 0.82 [95% CI, 0.61–1.09]; P=0.167), but visual inspection of pooled Kaplan–Meier curves suggested a divergence favoring S‐ICD. Secondary outcomes did not differ significantly between both modalities. Conclusions S‐ICD is clinically superior to TV‐ICD in terms of lead‐related complications while demonstrating comparable efficacy and safety. For device‐related complications, S‐ICD may be beneficial over TV‐ICD in the long term. These indicate that S‐ICD is likely a suitable substitute for TV‐ICD in patients requiring implantable cardioverter‐defibrillator implantation without a pacing indication.
Collapse
Affiliation(s)
- Khi Yung Fong
- Yong Loo Lin School of MedicineNational University of Singapore Singapore
| | | | - Yue Wang
- Department of Cardiology Changi General Hospital Singapore
| | - Colin Yeo
- Department of Cardiology Changi General Hospital Singapore
| | - Vern Hsen Tan
- Department of Cardiology Changi General Hospital Singapore
| |
Collapse
|
23
|
Begisbayev T, Kosherbayeva L, Akhmetov V, Khvan D, Brimzhanova M. Implantation of Implantable Cardioverter Defibrillators in Kazakhstan. Glob Heart 2022; 17:30. [PMID: 35586742 PMCID: PMC9104561 DOI: 10.5334/gh.1119] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 04/16/2022] [Indexed: 11/25/2022] Open
Abstract
Background and Objectives Implantation of implantable cardioverter-defibrillators (ICD) has increased significantly over the past decade. However, limited data exist regarding practices and policies of ICD implantations in Kazakhstan. We aimed to provide an overview of the current use of ICD in Kazakhstan. Methods Using the Unified Healthcare Information System database of the entire Kazakh adult population, statistical and cost data of ICD implantations in 2017-2019 were evaluated. Cardiologists and electrophysiologists working in cardio surgery centers and departments were asked to go through an online survey focused on subcutaneous-ICD (S-ICD) experience. Results Implantation of traditional transvenous cardioverter-defibrillators for residents of Kazakhstan is fully reimbursed. A total of 2,263 ICD interventions (2,252 new implantations and 11 reimplantations) were performed across the country during the study period. According to the tariffs approved by the Ministry of Health, the reimbursement cost for one ICD case is about 14,061.80 US dollars. The survey showed that only two hospitals have implanted S-ICDs. Among the main reasons why S-ICD is not widely used in the country the following were named: lack of trained staff (61.1% of respondents); the cost of device and lack of reimbursement (38.7%); and lack of pacing function (27.8%). Conclusion The number of ICD implantation in Kazakhstan is steadily continuing to grow, although, compared to developed countries, the implantation rate especially for S-ICD remains low. There is a need in deliberate strategies to remove policy barriers for implementation the most innovative cardiac implantable electronic devices implantations such as S-ICD in the country.
Collapse
Affiliation(s)
| | - Lyazzat Kosherbayeva
- Asfendiyarov Kazakh National Medical University, Almaty, Kazakhstan
- Al-Farabi Kazakh National University, Almaty, Kazakhstan
| | | | - Dmitry Khvan
- National Medical Research Center named after Academician E. Meshalkin, Ministry of Health of the Russian Federation, Kazakhstan
| | | |
Collapse
|
24
|
Khanra D, Hamid A, Patel P, Tomson J, Abdalla A, Khan N, Dowd R, Chandan N, Osagie C, Jinadu T, Velu S, Arya A, Spencer C, Barr C, Petkar S. A real-world experience of subcutaneous and transvenous implantable cardiac defibrillators-comparison with the PRAETORIAN study. J Arrhythm 2022; 38:199-212. [PMID: 35387142 PMCID: PMC8977574 DOI: 10.1002/joa3.12687] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 01/03/2022] [Accepted: 01/05/2022] [Indexed: 11/06/2022] Open
Abstract
Background PRAETORIAN is the first randomized controlled trial that demonstrated the noninferiority of subcutaneous ICD (S-ICD) in comparison with transvenous ICD (TV-ICD). We retrospectively reviewed electronic records of patients with ICD implanted over the past 6 years, with the primary objective to compare our real-world single tertiary center experience with the randomized data from the PRAETORIAN study. Methods Seventy S-ICD patients were compared with 197 TV-ICD patients, from July 2014 to June 2020 retrospectively, over a median period of 1304 days (296-2451 days). Primary composite endpoints included inappropriate shocks and device-related malfunctions. Results Patients with S-ICD implantation were younger than those who received TV-ICD (mean, 49.7 years vs 63.9 years, p < .001). About 31.4% of S-ICDs were implanted for secondary prevention, and 58.6% of S-ICD patients had ischemic cardiomyopathy (ICM) with a median left ventricular ejection fraction of 32.5% (range: 10-67%). S-ICDs and TV-ICD had statistically similar inappropriate shocks (4.3% vs 4.6%, p = .78), device-related complications (11.4% vs 9.1%, p = .93), and the overall primary endpoints (15.7% vs 13.7%, p = .68). The findings remained the same even after age and gender adjustments and time-dependent analysis. Conclusion Although single-center experience with a small number of S-ICD patients, results of the PRAETORIAN study has been replicated in our real-world experience of S-ICD and TV-ICD implantations across diverse etiologies, indications, and age groups confirming the comparable performance of S-ICD and TV-ICD when implanted in selected patients.
Collapse
Affiliation(s)
- Dibbendhu Khanra
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Abdul Hamid
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Peysh Patel
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - John Tomson
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Ahmed Abdalla
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Nasrin Khan
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Rory Dowd
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Nakul Chandan
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Christopher Osagie
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Tomilola Jinadu
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Selvakumar Velu
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Anita Arya
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Charles Spencer
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Craig Barr
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| | - Sanjiv Petkar
- New Cross Hospital, Heart and Lung Centre, Division of Electrophysiology and DevicesRoyal Wolverhampton NHS TrustUK
| |
Collapse
|
25
|
Gulletta S, Gasperetti A, Schiavone M, Vogler J, Fastenrath F, Breitenstein A, Laredo M, Palmisano P, Mitacchione G, Compagnucci P, Kaiser L, Hakmi S, Angeletti A, De Bonis S, Picarelli F, Arosio R, Casella M, Steffel J, Fierro N, Guarracini F, Santini L, Pignalberi C, Piro A, Lavalle C, Pisanò E, Viecca M, Curnis A, Badenco N, Ricciardi D, Russo AD, Tondo C, Kuschyk J, Bella PD, Biffi M, Forleo GB, Tilz R. Age-related differences and associated mid-term outcomes of subcutaneous implantable cardioverter defibrillators: a propensity-matched analysis from a multicenter European registry. Heart Rhythm 2022; 19:1109-1115. [DOI: 10.1016/j.hrthm.2022.02.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 02/22/2022] [Accepted: 02/23/2022] [Indexed: 12/24/2022]
|
26
|
Markman TM, Brozoski J, Bode W, Nazarian S. A novel use of a subcutaneous implantable cardioverter-defibrillator algorithm to detect bradycardia. HeartRhythm Case Rep 2022; 8:164-166. [PMID: 35492847 PMCID: PMC9039570 DOI: 10.1016/j.hrcr.2021.11.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
27
|
Carrington M, Providência R, Chahal CAA, D'Ascenzi F, Cipriani A, Ricci F, Khanji MY. Cardiopulmonary Resuscitation and Defibrillator Use in Sports. Front Cardiovasc Med 2022; 9:819609. [PMID: 35242826 PMCID: PMC8885805 DOI: 10.3389/fcvm.2022.819609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 01/04/2022] [Indexed: 11/16/2022] Open
Abstract
Sudden cardiac arrest (SCA) in young athletes is rare, with an estimated incidence ranging from 0.1 to 2 per 100,000 per athlete year. The creation of SCA registries can help provide accurate data regarding incidence, treatment, and outcomes and help implement primary or secondary prevention strategies that could change the course of these events. Early cardiopulmonary resuscitation (CPR) and defibrillation are the most important determinants of survival and neurological prognosis in individuals who suffer from SCA. Compared with the general population, individuals with clinically silent cardiac disease who practice regular physical exercise are at increased risk of SCA events. While the implementation of national preparticipation screening has been largely debated, with no current consensus, the number of athletes who will be diagnosed with cardiac disease and have an indication for implantable defibrillator cardioverter defibrillator (ICD) is unknown. Many victims of SCA do not have a previous cardiac diagnosis. Therefore, the appropriate use and availability of automated external defibrillators (AEDs) in public spaces is the crucial part of the integrated response to prevent these fatalities both for participating athletes and for spectators. Governments and sports institutions should invest and educate members of the public, security, and healthcare professionals in immediate initiation of CPR and early AED use. Smartphone apps could play an integral part to allow bystanders to alert the emergency services and CPR trained responders and locate and utilize the nearest AED to positively influence the outcomes by strengthening the chain of survival. This review aims to summarize the available evidence on sudden cardiac death prevention among young athletes and to provide some guidance on strategies that can be implemented by governments and on the novel tools that can help save these lives.
Collapse
Affiliation(s)
- Mafalda Carrington
- Department of Cardiology, Hospital do Espírito Santo de Évora, Évora, Portugal
| | - Rui Providência
- Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London, United Kingdom
- Department of Cardiology, Newham University Hospital, Barts Health NHS Trust, London, United Kingdom
- Institute of Health Informatics Research, University College London, London, United Kingdom
| | - C. Anwar A. Chahal
- Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London, United Kingdom
- Cardiovascular Division, University of Pennsylvania, Philadelphia, PA, United States
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, United States
- Centre for Inherited Cardiovascular Diseases, WellSpan Cardiology, Lancaster, PA, United States
| | - Flavio D'Ascenzi
- Division of Cardiology, Department of Medical Biotechnologies, University of Siena, Siena, Italy
| | - Alberto Cipriani
- Department of Cardio-Thoraco-Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Fabrizio Ricci
- Department of Neuroscience, Imaging and Clinical Sciences, “G.d'Annunzio” University of Chieti-Pescara, Chieti, Italy
- Department of Cardiology, Casa di Cura Villa Serena, Città Sant'Angelo, Italy
- Department of Clinical Sciences, Lund University, Malmö, Sweden
| | - Mohammed Y. Khanji
- Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London, United Kingdom
- Department of Cardiology, Newham University Hospital, Barts Health NHS Trust, London, United Kingdom
- NIHR Biomedical Research Unit, William Harvey Research Institute, Queen Mary University, London, United Kingdom
| |
Collapse
|
28
|
Thienel M, Haum M, Sadoni S, Novotny J, Estner HL, Fichtner S, Lackermair K. Impairment of Quality of Life in Patients with Implanted Subcutaneous Cardioverter Defibrillator (S-ICD) Compared to Implanted Transvenous Cardioverter Defibrillator Therapy. Patient Prefer Adherence 2022; 16:3027-3033. [PMID: 36387054 PMCID: PMC9645128 DOI: 10.2147/ppa.s378741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 10/05/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND The subcutaneous cardioverter defibrillator (S-ICD) has been shown to be a viable alternative to transvenous ICDs (TV-ICD) in all patients at risk of sudden cardiac death (SCD) but without pacing indication. AIM The aim of this study was to examine the impact of therapy with current S-ICD devices on quality of life (QoL) in comparison to patients with TV-ICD devices. METHODS In our single-centre study, 52 consecutive patients with S-ICD and 52 matched patients with TV-ICD were analysed. QoL has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data were evaluated. RESULTS Two-thirds of the total study population reported restrictions in daily routine compared to their life before ICD implantation. A total of 27.7% of S-ICD patients stated to expect an improvement of QoL by deactivation or explantation of their defibrillator compared to only 6.4% of patients with TV-ICD (p=0.006), which was mainly caused by discomfort and pain from the S-ICD pocket (relevant discomfort and pain in 32.6% vs 11.5%; p<0.01). LIMITATIONS Main limitation of the study is that quality of life was assessed for one single time point only and time since implantation differed significantly between S-ICD and TV-ICD. Furthermore our collective is younger, and, due to the high proportion of patients without cardiomyopathy, the mean EF is better than usual ICD collective. The absence of heart failure in about the half of our patients might have relevant impact on our QoL analysis. CONCLUSION A relevant proportion of S-ICD patients expects an improvement of QoL by explantation of the device. Of note, this impression was not driven by the fear of receiving shocks but mainly by discomfort and pain caused by the pulse generator.
Collapse
Affiliation(s)
- Manuela Thienel
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Magda Haum
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Sebastian Sadoni
- Department of Cardiac Surgery, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Julia Novotny
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Heidi L Estner
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Stephanie Fichtner
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
| | - Korbinian Lackermair
- Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Munich, Germany
- Correspondence: Korbinian Lackermair, Department of Medicine I, Munich University Hospital, Ludwig-Maximilian-University, Marchioninistr. 15, Munich, 81377, Germany, Email
| |
Collapse
|
29
|
Siskin M, Cerrone M, Shokr M, Aizer A, Barbhaiya C, Dai M, Bernstein S, Holmes D, Knotts R, Park DS, Spinelli M, Chinitz LA, Jankelson L. ICD shocks and complications in patients with inherited arrhythmia syndromes. IJC HEART & VASCULATURE 2021; 37:100908. [PMID: 34765721 PMCID: PMC8569698 DOI: 10.1016/j.ijcha.2021.100908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 10/25/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. METHODS Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. RESULTS 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. CONCLUSION The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Lior Jankelson
- Corresponding author at: Leon H. Charney Division of Cardiology New York University Langone Health 516 1st Avenue, New York 10016, USA.
| |
Collapse
|
30
|
Nso N, Nassar M, Lakhdar S, Enoru S, Guzman L, Rizzo V, Munira MS, Radparvar F, Thambidorai S. Comparative Assessment of Transvenous versus Subcutaneous Implantable Cardioverter-defibrillator Therapy Outcomes: An Updated Systematic Review and Meta-analysis. Int J Cardiol 2021; 349:62-78. [PMID: 34801615 DOI: 10.1016/j.ijcard.2021.11.029] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 10/13/2021] [Accepted: 11/12/2021] [Indexed: 01/05/2023]
Abstract
BACKGROUND Subcutaneous (S-ICD) and transvenous (TV-ICD) implantable cardioverter-defibrillator devices effectively reduce the incidence of sudden cardiac death in patients at a high risk of ventricular arrhythmias. This study aimed to evaluate the safe replacement of TV-ICD with S-ICD based on updated recent evidence. METHODS We systematically searched EMBASE, JSTOR, PubMed/MEDLINE, and Cochrane Library on 30 July 2021 following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. RESULTS We identified 26 studies that examined 7542 (58.27%) patients with S-ICD and 5400 (41.72%) with TV-ICD. The findings indicated that, compared to patients with TV-ICD, patients with S-ICD had a lower incidence of defibrillation lead failure (odds ratio [OR], 0.12; 95% confidence interval [CI], 0.01-0.98; p = 0.05), lead displacement or fracture (OR, 0.25; 95% CI, 0.12-0.86; p = 0.0003), pneumothorax and/or hemothorax (OR: 0.22, 95% CI 0.05, 0.97, p = 0.05), device failure (OR: 0.70, 95% CI 0.51, 0.95, p = 0.02), all-cause mortality (OR: 0.44 [95% CI 0.32, 0.60], p < 0.001), and lead erosion (OR: 0.01, 95% CI 0.00, 0.05, p < 0.001). Patients with TV-ICD had a higher incidence of pocket complications than patients with S-ICD (OR, 2.13; 95% CI, 1.23-3.69; p = 0.007) and a higher but insignificant incidence of inappropriate sensing (OR, 3.53; 95% CI, 0.97-12.86; p = 0.06). CONCLUSIONS The S-ICD algorithm was safer and more effective than the TV-ICD system as it minimized the incidence of pocket complications, lead displacement or fracture, inappropriate sensing, defibrillation lead failure, pneumothorax/hemothorax, device failure, lead erosion, and all-cause mortality. Future studies should explore the scope of integrating novel algorithms with the current S-ICD systems to improve cardiovascular outcomes.
Collapse
Affiliation(s)
- Nso Nso
- Department of Medicine, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA.
| | - Mahmoud Nassar
- Department of Medicine, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Sofia Lakhdar
- Department of Medicine, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Sostanie Enoru
- Division of Cardiovascular Disease, SUNY Downstate Medical Center, NY, USA
| | - Laura Guzman
- Department of Medicine, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Vincent Rizzo
- Department of Medicine, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Most S Munira
- Division of Cardiovascular Disease, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Farshid Radparvar
- Division of Cardiovascular Disease, Icahn School of Medicine at Mount Sinai/NYC H+H/Queens, NY, USA
| | - Senthil Thambidorai
- Cardiovascular Medicine Division, HCA Medical City of Fort Worth, TX/Medicine -TCU and UNTHSc School of Medicine, Fort Worth, TX, USA
| |
Collapse
|
31
|
Gasperetti A, Schiavone M, Biffi M, Casella M, Compagnucci P, Mitacchione G, Angeletti A, Vogler J, Proietti R, Ziacchi M, Dello Russo A, Natale A, Tilz RR, Forleo GB. Intraprocedural PRAETORIAN score for early assessment of S-ICD implantation: A proof-of-concept study. J Cardiovasc Electrophysiol 2021; 32:3035-3041. [PMID: 34582055 DOI: 10.1111/jce.15254] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 08/25/2021] [Accepted: 09/20/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The PRAETORIAN score (PS) was developed to assess the implant position and predict defibrillation success of the subcutaneous implantable cardioverter defibrillators (S-ICD). The main critique moved to the routine use of PS has been its postprocedural timing, that limits its usefulness on procedure guidance. The aim of this proof-of-concept study was to assess the feasibility of an intraprocedural use of PS. METHODS Forty consecutive patients undergoing S-ICD implantation were enrolled. Intraprocedural PS (IP-PS) obtained with fluoroscopy before closure of the pocket and postprocedural PS (PP-PS) obtained with two-views chest X-ray were compared. Intraprocedural data and PS were compared with the historic cohorts of the involved institutions. RESULTS When assessing IP-PS and PP-PS, a complete overall agreement was observed (100%, 1.00-κ; p < .001). When assessing a per-step agreement, a very high-degree of concordance in evaluating Step 1 of the PS was observed (95%, 0.81-κ; p < .001). A complete agreement in Step 2-3 (100%, 1.00-κ; p < .001) of the PS was reported. In comparison with our historical cohort, procedural time in the IP-PS cohort did not increase (45 [41-52] vs. 45 [39-49] min; p = .351) while the expected increase in fluoroscopy time resulted scarce (15 [10-15] s). CONCLUSION An IP-PS can be reliably obtained using fluoroscopy guidance during S-ICD implantation, without a significant increase in procedural duration and may serve as guidance for implanting physicians, to avoid postprocedural S-ICD repositioning, leading to patient discomfort and significantly enhancing infective risks. IP-PS showed a very high agreement with the PP-PS obtained from two-views chest X-ray.
Collapse
Affiliation(s)
- Alessio Gasperetti
- Cardiology Unit, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Marco Schiavone
- Cardiology Unit, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Mauro Biffi
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine-DIMES, University of Bologna, Bologna, Italy
| | - Michela Casella
- Department of Biomedical Sciences and Public Health, Cardiology and Arrhythmology Clinic, University Hospital Umberto I-Salesi-Lancisi, Marche Polytechnic University, Ancona, Italy
| | - Paolo Compagnucci
- Department of Biomedical Sciences and Public Health, Cardiology and Arrhythmology Clinic, University Hospital Umberto I-Salesi-Lancisi, Marche Polytechnic University, Ancona, Italy
| | - Gianfranco Mitacchione
- Cardiology Unit, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Andrea Angeletti
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine-DIMES, University of Bologna, Bologna, Italy
| | | | - Riccardo Proietti
- Cardiology Unit, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Matteo Ziacchi
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine-DIMES, University of Bologna, Bologna, Italy
| | - Antonio Dello Russo
- Department of Biomedical Sciences and Public Health, Cardiology and Arrhythmology Clinic, University Hospital Umberto I-Salesi-Lancisi, Marche Polytechnic University, Ancona, Italy
| | - Andrea Natale
- Department of Electrophysiology, Texas Cardiac Arrhythmia Institute (TCAI) at Saint David's Hospital, Austin, Texas, USA
| | - Roland R Tilz
- Department of Electrophysiology, Medical Clinic II, University Heart Center Lübeck, Lübeck, Germany
| | - Giovanni B Forleo
- Cardiology Unit, ASST Fatebenefratelli-Sacco, Luigi Sacco University Hospital, Milan, Italy
| |
Collapse
|
32
|
Frausing MHJP, Kronborg MB, Johansen JB, Nielsen JC. Avoiding implant complications in cardiac implantable electronic devices: what works? Europace 2021; 23:163-173. [PMID: 33063088 DOI: 10.1093/europace/euaa221] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/08/2020] [Indexed: 01/14/2023] Open
Abstract
Nearly one in ten patients experience complications in relation to cardiac implantable electronic device (CIED) implantations. CIED complications have serious implications for the patients and for the healthcare system. In light of the rising rates of new implants and consistent rate of complications, primary prevention remains a major concern. To guide future efforts, we sought to review the evidence base underlying common preventive actions made during a primary CIED implantation.
Collapse
Affiliation(s)
| | - Mads Brix Kronborg
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld. 99, DK-8200, Aarhus, Denmark
| | - Jens Brock Johansen
- Department of Cardiology, Odense University Hospital, J. B. Winsløvs Vej 4, DK-5000, Odense, Denmark
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld. 99, DK-8200, Aarhus, Denmark
| |
Collapse
|
33
|
Ochman AR, Riesbeck M, Corbisiero R. Inappropriate shock caused by P- and T-wave oversensing in a subcutaneous implantable cardiac defibrillator in a patient in sinus rhythm. HeartRhythm Case Rep 2021; 7:433-435. [PMID: 34307022 PMCID: PMC8283424 DOI: 10.1016/j.hrcr.2020.11.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
34
|
Long-term complications in patients implanted with subcutaneous implantable cardioverter-defibrillators: Real-world data from the extended ELISIR experience. Heart Rhythm 2021; 18:2050-2058. [PMID: 34271173 DOI: 10.1016/j.hrthm.2021.07.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 06/21/2021] [Accepted: 07/07/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND Recently, the Food and Drug Administration issued a recall for the subcutaneous implantable cardioverter-defibrillator (S-ICD) because of the possibility of lead ruptures and accelerated battery depletion. OBJECTIVE The aim of this study was to evaluate device-related complications over time in a large real-world multicenter S-ICD cohort. METHODS Patients implanted with an S-ICD from January 2015 to June 2020 were enrolled from a 19-institution European registry (Experience from the Long-term Italian S-ICD registry [ELISIR]; ClinicalTrials.gov identifier NCT0473876). Device-related complication rates over follow-up were collected. Last follow-up of patients was performed after the Boston Scientific recall issue. RESULTS A total of 1254 patients (median age 52.0 [interquartile range 41.0-62.2] years; 973 (77.6%) men; 387 (30.9%) ischemic) was enrolled. Over a follow-up of 23.2 (12.8-37.8) months, complications were observed in 117 patients (9.3%) for a total of 127 device-related complications (23.6% managed conservatively and 76.4% required reintervention). Twenty-seven patients (2.2%) had unanticipated generator replacement after 3.6 (3.3-3.9) years, while 4 (0.3%) had lead rupture. Body mass index (hazard ratio [HR] 1.063 [95% confidence interval 1.028-1.100]; P < .001), chronic kidney disease (HR 1.960 [1.191-3.225]; P = .008), and oral anticoagulation (HR 1.437 [1.010-2.045]; P = .043) were associated with an increase in overall complications, whereas older age (HR 0.980 [0.967-0.994]; P = .007) and procedure performed in high-volume centers (HR 0.463 [0.300-0.715]; P = .001) were protective factors. CONCLUSION The overall complication rate over 23.2 months of follow-up in a multicenter S-ICD cohort was 9.3%. Early unanticipated device battery depletions occurred in 2.2% of patients, while lead fracture was observed in 0.3%, which is in line with the expected rates reported by Boston Scientific.
Collapse
|
35
|
Karimianpour A, John L, Gold MR. The Subcutaneous ICD: A Review of the UNTOUCHED and PRAETORIAN Trials. Arrhythm Electrophysiol Rev 2021; 10:108-112. [PMID: 34401183 PMCID: PMC8353550 DOI: 10.15420/aer.2020.47] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 02/17/2021] [Indexed: 11/05/2022] Open
Abstract
The ICD is an important part of the treatment and prevention of sudden cardiac death in many high-risk populations. Traditional transvenous ICDs (TV-ICDs) are associated with certain short- and long- term risks. The subcutaneous ICD (S-ICD) was developed in order to avoid these risks and complications. However, this system is associated with its own set of limitations and complications. First, patient selection is important, as S-ICDs do not provide pacing therapy currently. Second, pre-procedural screening is important to minimise T wave and myopotential oversensing. Finally, until recently, the S-ICD was primarily used in younger patients with fewer co-morbidities and less structural heart disease, limiting the general applicability of the device. S-ICDs achieve excellent rates of arrhythmia conversion and have demonstrated noninferiority to TV-ICDs in terms of complication rates in real-world studies. The objective of this review is to discuss the latest literature, including the UNTOUCHED and PRAETORIAN trials, and to address the risk of inappropriate shocks.
Collapse
Affiliation(s)
- Ahmadreza Karimianpour
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| | - Leah John
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| | - Michael R Gold
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| |
Collapse
|
36
|
Elias Neto J. Importance of the Anesthetic Technique and Analgesia in the Implantation of Subcutaneous and Endovascular Defibrillator: An Aspect Often Ignored. Arq Bras Cardiol 2021; 116:1150-1152. [PMID: 34133602 PMCID: PMC8288522 DOI: 10.36660/abc.20210184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Affiliation(s)
- Jorge Elias Neto
- Vitória Apart Hospital - Serviço de Eletrofisiologia, Serra , ES - Brasil
| |
Collapse
|
37
|
Evaluation of subcutaneous implantable cardioverter-defibrillator performance in patients with ion channelopathies from the EFFORTLESS cohort and comparison with a meta-analysis of transvenous ICD outcomes. Heart Rhythm O2 2021; 1:326-335. [PMID: 34113890 PMCID: PMC8183957 DOI: 10.1016/j.hroo.2020.10.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to conventional transvenous ICD (TV-ICD) therapy to reduce lead complications. Objective To evaluate outcomes in channelopathy vs patients with structural heart disease in the EFFORTLESS-SICD Registry and with a previously reported TV-ICD meta-analysis in channnelopathies. Methods The EFFORTLESS registry includes 199 patients with channelopathies (Brugada syndrome 83, long QT syndrome 24, idiopathic ventricular fibrillation 78, others 14) and 786 patients with structural heart disease. Results Channelopathy patients were younger (39 ± 14 years vs 51 ± 17 years; P < .001) with left ventricular ejection fraction 59% ± 9% vs 41% ± 18% (P < .001). The complication rate (follow-up: 3.2 ± 1.5 years vs 3.0 ± 1.5 years) was similar: 13.6% vs 11.2% (P = .42). Appropriate shocks rates were 9.5% vs 10.8% (P = .70), with shocks for monomorphic ventricular tachycardia being 2.0% vs 6.9% (P < .02) and for polymorphic ventricular tachycardia/ventricular fibrillation (VT/VF) 8.0% vs 5.7% (P = .30). Conversion effectiveness of VT/VF episodes was similar: 36 of 37 (97.3%) vs 151 of 155 (97.4%, P = .59). VT/VF storm event (2% vs 0.9%, P = .33) and lower inappropriate shock (IAS) (8.5% vs 12.5%, P = .12) rates were statistically similar between channelopathy and non-channelopathy patients, with 45.5% channelopathy vs 31.4% non-channelopathy patients managed with a conditional zone > 200 beats per minute (P = .0002). Annualized appropriate shock, IAS, and complication rates appear to be lower for the S-ICD vs meta-analysis TV-ICD patients, particularly lead complications. Conclusion EFFORTLESS demonstrates similar S-ICD efficacy and a nonsignificant, lower rate of IAS in channelopathy patients as compared to structural heart disease. Comparable IAS rates were achieved with the device programmed to higher rates for channelopathy patients.
Collapse
|
38
|
Cheema MA, Almas T, Ullah W, Haas D. RV lead placement - A forgotten cause of right heart failure. Ann Med Surg (Lond) 2021; 67:102461. [PMID: 34158932 PMCID: PMC8203726 DOI: 10.1016/j.amsu.2021.102461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 05/26/2021] [Accepted: 06/01/2021] [Indexed: 11/29/2022] Open
Abstract
Introduction Cardiac implantable electronic devices (CIEDs) have opened new doors, improving the quality, and increasing the duration of life by providing support of heart rate, atrioventricular and interventricular synchrony, thereby preventing sudden cardiac death. Nevertheless, these devices can pose some risks to the patients, including pacemaker-mediated cardiomyopathy and endocarditis. Case presentation We elucidate the case of a patient who had severe Tricuspid Regurgitation as a result of single chamber Implantable Cardioverter Defibrillator (ICD) placement which led to right heart failure (RHF). His chief complaints were generalized fatigability and difficulty climbing steps at home. He also had orthopnea but denies paroxysmal nocturnal dyspnea. Despite using home diuretic regimen (Torsemide 40 gm daily), his continued to increase. He did not respond well to intravenous diuretics that time so decision was made to start Aquapheresis to which he responded very well Discussion TV dysfunction associated with CIED leads can be investigated and diagnosed using different techniques. These pillars of diagnostic tests include two-dimensional (2D), 3D, and Doppler echocardiography. Presence of holosystolic hepatic vein flow reversal is key in diagnosing severe TR, whereas normal antegrade systolic flow excludes the possibility of moderate and severe TR. Conclusion CIED leads causing tricuspid valve impairment has become increasingly recognized over the recent times; however, the evidence underlying this trend has been derived primarily from retrospective analyses. In order to circumvent these issues, leadless pacemakers and subcutaneous ICD devices should be considered. •CIED leads causing TV dysfunction has gained increasing recognition recently but all evidence supporting this premise emanates from retrospective analyses. •When clinical, hemodynamic, and echocardiographic assessment provides compelling evidence of lead related severe TR, corrective intervention should be provided in a timely fashion, before the onset of severe annular and chamber dilation and severe RV dysfunction because, by that time, the lead itself will no longer be the problem, and the extant problem may not be as amenable to corrective intervention. •Leadless pacemakers and subcutaneous ICD devices likely to be associated with a reduction in lead-related cardiac dysfunction.
Collapse
Affiliation(s)
| | - Talal Almas
- RCSI University of Medicine and Health Sciences, Dublin, Ireland
| | | | | |
Collapse
|
39
|
Dhawan R, Ahmad M, Jhand A, Kanwal S, Jamil A, Khan F. Two Limitations of Subcutaneous Implantable Cardioverter Defibrillator in the Same Patient Warranting Its Explant. AMERICAN JOURNAL OF CASE REPORTS 2021; 22:e928983. [PMID: 33911064 PMCID: PMC8097742 DOI: 10.12659/ajcr.928983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND A subcutaneous implantable cardioverter defibrillator (S-ICD) is preferred over a transvenous implantable cardioverter defibrillator (TV-ICD) in selected cases owing to a lower rate of lead-related complications such as infections and venous thrombosis. However, the S-ICD has its own limitations, including inappropriate shocks due to oversensed events, and the inability to treat ventricular tachycardia (VT) below a heart rate of 170 beats per minutes (bpm). We present a patient case which showed manifestations of both of these limitations, warranting explant of the device. CASE REPORT A 50-year-old man with a history of nonischemic cardiomyopathy and VT had a S-ICD placed at an outside facility. However, he continued to have VT despite on anti-arrhythmic drugs and required recurrent S-ICD shocks. Device interrogation showed that he was intermittently receiving appropriate shocks for slower VT (with a heart rate ranging from 150 bpm to 160 bpm) due to oversensing of T waves. However, treatment was delayed for other VT episodes owing to appropriate sensing and the patient's heart rate being below the lowest detection zone for S-ICD. Due to slower VT cycle length and frequent oversensed events, the S-ICD was ultimately replaced by a TV-ICD system. CONCLUSIONS This case report emphasizes the importance of S-ICD pre-implant vector screening and the need for paying attention to VT cycle length to prevent inappropriate device shocks and/or delayed therapies.
Collapse
Affiliation(s)
- Rahul Dhawan
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Mansoor Ahmad
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Aravdeep Jhand
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Sumera Kanwal
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Adeel Jamil
- Department of Medicine, OSF Healthcare St. Francis Medical Center, Peoria, IL, USA
| | - Faris Khan
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| |
Collapse
|
40
|
Abstract
Cardiac implantable electronic devices (CIEDs) are essential for the management of a variety of cardiac conditions, including tachyarrhythmias, bradyarrhythmias, and medically refractory heart failure (HF). Recent advancements in CIED technology have led to innovative solutions that overcome shortcomings associated with traditional devices or address unmet needs. Leadless pacemakers, subcutaneous implantable cardioverter defibrillators (ICDs), and extravascular ICDs eliminate lead-related complications common with conventional pacemakers or ICDs. Conduction system pacing (His bundle pacing and left bundle branch pacing) is a more physiologic method of pacing and avoids the deleterious consequences associated with long-term right ventricular pacing. For HF-related devices, cardiac contractility modulation is an emerging therapy that bridges a gap for many patients ineligible for cardiac resynchronization therapy and has been shown to improve HF symptoms and decrease hospitalizations and mortality in select patients. Implantable pulmonary artery pressure monitors help guide HF management and reduce hospitalizations. Lastly, new phrenic nerve stimulating devices are being utilized to treat central sleep apnea, a common comorbidity associated with HF. While further long-term studies are still underway for many of these new technologies, it is anticipated that these devices will become indispensable therapeutics in the expanding cardiovascular armamentarium.
Collapse
|
41
|
Tamura S, Yoshiyama T, Doi A, Yoshiyama M. Absence of shock therapy related to improper sensing of noise on the defibrillation test during subcutaneous implantable cardioverter-defibrillator implantation: a case report. EUROPEAN HEART JOURNAL-CASE REPORTS 2021; 4:1-6. [PMID: 33447710 PMCID: PMC7793213 DOI: 10.1093/ehjcr/ytaa469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 05/27/2020] [Accepted: 11/09/2020] [Indexed: 11/21/2022]
Abstract
Background Subcutaneous implantable cardioverter–defibrillator (S-ICD) represents an efficient alternative to transvenous ICD in patients who do not require pacing. The intraoperative defibrillation test (DFT) is recommended during S-ICD implantation to confirm appropriate sensing and successful 65-J termination of induced ventricular fibrillation (VF). However, few cases of oversensing of noise inhibiting therapies have been reported. Case summary We report the case of a 50-year-old man who underwent S-ICD implantation for secondary prevention of sudden cardiac death. Immediately after S-ICD implantation, VF was induced using a 50-Hz burst; however, shock was not delivered owing to sustained noise on the electrogram in the primary vector. Therefore, an external rescue shock was needed at 150 J. We changed the sensing vector from primary to secondary and performed a second DFT. The S-ICD could deliver an appropriate shock and was able to successfully terminate VF without noise markers in the secondary vector. During the second DFT, one back-up pacing was delivered after the shock; the sensing vector then automatically switched from the secondary to the alternate vector. However, noise was observed in the alternate vector despite sinus rhythm restoration. Discussion The present case demonstrated that noise was recorded in two different vectors during DFT, possibly supporting the hypothesis that the muscle spasm of the diaphragm induced by the 50-Hz burst causes oversensing of noise by the S-ICD.
Collapse
Affiliation(s)
- Shota Tamura
- Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, 1-4-3 Asahimachi, Abeno-ku, Osaka 545-8585, Japan
| | - Tomotaka Yoshiyama
- Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, 1-4-3 Asahimachi, Abeno-ku, Osaka 545-8585, Japan
| | - Atsushi Doi
- Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, 1-4-3 Asahimachi, Abeno-ku, Osaka 545-8585, Japan
| | - Minoru Yoshiyama
- Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, 1-4-3 Asahimachi, Abeno-ku, Osaka 545-8585, Japan
| |
Collapse
|
42
|
Ricciardi D, Ziacchi M, Gasperetti A, Schiavone M, Picarelli F, Diemberger I, Bontempi L, Di Belardino N, Bisignani G, De Bonis S, Mitacchione G, Calabrese V, Lavalle C, Piro A, Pignalberi C, Santini L, Grigioni F, Tondo C, Biffi M, Forleo GB. Clinical impact of defibrillation testing in a real‐world S‐ICD population: Data from the ELISIR registry. J Cardiovasc Electrophysiol 2020; 32:468-476. [DOI: 10.1111/jce.14833] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 10/29/2020] [Accepted: 11/19/2020] [Indexed: 11/26/2022]
Affiliation(s)
- Danilo Ricciardi
- Department of Cardiology Policlinico Universitario Campus Bio‐Medico Roma Italy
| | - Matteo Ziacchi
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine‐DIMES University of Bologna Bologna Italy
| | | | | | - Francesco Picarelli
- Department of Cardiology Policlinico Universitario Campus Bio‐Medico Roma Italy
- Department of Cardiology Ospedali Riuniti Anzio‐Nettuno Anzio Italy
| | - Igor Diemberger
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine‐DIMES University of Bologna Bologna Italy
| | - Luca Bontempi
- Department of Cardiology Spedali Civili Brescia Brescia Italy
| | | | - Giovanni Bisignani
- Department of Cardiology Ospedale “Ferrari”, Castrovillari Cosenza Italy
| | - Silvia De Bonis
- Department of Cardiology Ospedale “Ferrari”, Castrovillari Cosenza Italy
| | | | - Vito Calabrese
- Department of Cardiology Policlinico Universitario Campus Bio‐Medico Roma Italy
| | - Carlo Lavalle
- Department of Cardiovascular/Respiratory Diseases, Nephrology, Anesthesiology, and Geriatric Sciences Policlinico Umberto I Sapienza University of Rome Rome Italy
| | - Agostino Piro
- Department of Cardiovascular/Respiratory Diseases, Nephrology, Anesthesiology, and Geriatric Sciences Policlinico Umberto I Sapienza University of Rome Rome Italy
| | | | - Luca Santini
- Division of Cardiology Ospedale G.B. Grassi Ostia Italy
| | - Francesco Grigioni
- Department of Cardiology Policlinico Universitario Campus Bio‐Medico Roma Italy
| | - Claudio Tondo
- Heart Rhythm Center Centro Cardiologico Monzino, IRCCS Milan Italy
- Department of Clinical Sciences and Community Health University of Milan Milan Italy
| | - Mauro Biffi
- Unit of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine‐DIMES University of Bologna Bologna Italy
| | | |
Collapse
|
43
|
Chernomordik F, Jons C, Klein HU, Kutyifa V, Nof E, Zareba W, Daubert JP, Greenberg H, Glikson M, Goldenberg I, Beinart R. Death with an implantable cardioverter-defibrillator: a MADIT-II substudy. Europace 2020; 21:1843-1850. [PMID: 31647531 DOI: 10.1093/europace/euz263] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 08/29/2019] [Indexed: 11/13/2022] Open
Abstract
AIMS There are limited data regarding factors that identify implantable cardioverter-defibrillator (ICD) patients who will experience either ventricular tachyarrhythmic (VTA) or non-arrhythmic (NA) mortality, and the commonly used clinical classification of sudden cardiac death (SCD) vs. non-sudden cardiac death (NSCD) may not be accurate enough. We aimed to correlate clinical adjudication of mortality events to device interrogation data and to identify risk factors for VTA mortality in Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II). METHODS AND RESULTS Of the 746 patients who received an ICD in MADIT-II, 44 died from cardiac causes and had available interrogation data at the time of death. Sudden cardiac death vs. NSCD was defined by an adjudication committee. Ventricular tachyarrhythmic and NA arrhythmic deaths were categorized by the presence or absence of ventricular tachycardia or fibrillation (VT/VF) during the terminal event. Mode of death was found to be inaccurate when validated by device interrogation for VTA events: 50% patients adjudicated as SCD did not have a VTA event at the time of death; and 25% of adjudicated NSCD were found to have VT/VF during the mortality event. Multivariate analysis showed that factors independently associated with VTA mortality included: VT/VF >72 h prior to the mortality event [hazard ratio (HR) 8.0; P < 0.001], hospitalization for heart failure (HR 6.7; P = 0.001), and a history of hypertension (HR 4; P = 0.04). CONCLUSION Current classification of SCD vs. NSCD fails to identify VTA events at the time of death in a significant proportion of patients, and simple clinical parameters can be used to identify ICD recipients with increased risk for VTA mortality.
Collapse
Affiliation(s)
- Fernando Chernomordik
- Leviev Heart Center, Sheba Medical Center, Ramat Gan, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,Divisions of Cardiology and Pulmonary and Critical Care Medicine, Cedars-Sinai Medical Center, Advanced Health Sciences Pavilion 127 S. San Vicente, Third Floor A3300, Los Angeles, CA 90048, USA
| | - Christian Jons
- Heart Research Follow-up Program, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA
| | - Helmut U Klein
- Heart Research Follow-up Program, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA
| | - Valentina Kutyifa
- Heart Research Follow-up Program, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA
| | - Eyal Nof
- Leviev Heart Center, Sheba Medical Center, Ramat Gan, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Wojciech Zareba
- Heart Research Follow-up Program, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA
| | | | - Henry Greenberg
- Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Michael Glikson
- Leviev Heart Center, Sheba Medical Center, Ramat Gan, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ilan Goldenberg
- Leviev Heart Center, Sheba Medical Center, Ramat Gan, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,Heart Research Follow-up Program, Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, NY, USA
| | - Roy Beinart
- Leviev Heart Center, Sheba Medical Center, Ramat Gan, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
44
|
Singh P, Afzal MR, Weiss R. Perioperative considerations during implantation of the subcutaneous defibrillator: State‐of‐the‐art review. Pacing Clin Electrophysiol 2020; 43:1451-1458. [DOI: 10.1111/pace.14072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 09/08/2020] [Indexed: 11/26/2022]
Affiliation(s)
- Prabhpreet Singh
- Division of Cardiovascular Medicine Wexner Medical Center, The Ohio State University Medical Center Columbus Ohio
| | - Muhammad Rizwan Afzal
- Division of Cardiovascular Medicine Wexner Medical Center, The Ohio State University Medical Center Columbus Ohio
| | - Raul Weiss
- Division of Cardiovascular Medicine Wexner Medical Center, The Ohio State University Medical Center Columbus Ohio
| |
Collapse
|
45
|
Rordorf R, Casula M, Pezza L, Fortuni F, Sanzo A, Savastano S, Vicentini A. Subcutaneous versus transvenous implantable defibrillator: An updated meta-analysis. Heart Rhythm 2020; 18:382-391. [PMID: 33212250 DOI: 10.1016/j.hrthm.2020.11.013] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/02/2020] [Accepted: 11/09/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND Implantable cardioverter-defibrillator (ICD) placement is a well-established therapy for prevention of sudden cardiac death. The subcutaneous implantable cardioverter-defibrillator (S-ICD) was specifically designed to overcome some of the complications related to the transvenous implantable cardioverter-defibrillator (TV-ICD), such as lead complications and systemic infections. Evidence on the comparison of S-ICD vs TV-ICD are limited. OBJECTIVE The purpose of this study was to conduct an updated meta-analysis comparing S-ICD vs TV-ICD. METHODS Electronic databases were searched for studies directly comparing clinical outcomes and complications between S-ICD and TV-ICD. The primary outcome was the composite of clinically relevant complications (lead, pocket, major procedural complications; device-related infections) and inappropriate shocks. Secondary outcomes included death and the individual components of the primary outcome. RESULTS Thirteen studies comprising 9073 patients were included in the analysis. Mean left ventricular ejection fraction was 40% ± 10%; 30% of patients were female; and 73% had an ICD implanted for primary prevention. There was no statistically significant difference in the risk of the primary outcome between S-ICD and TV-ICD (odds ratio [OR] 0.80; 95% confidence interval [CI] 0.53-1.19). Patients with S-ICD had lower risk of lead complications (OR 0.14; 95% CI 0.06-0.29; P <.00001) and major procedural complications (OR 0.18; 95% CI 0.06-0.57; P = .003) but higher risk of pocket complications (OR 2.18; 95% CI 1.30-3.66; P = .003) compared to those with TV-ICD. No significant differences were found for the other outcomes. CONCLUSION In patients with an indication for ICD without the need for pacing, TV-ICD and S-ICD are overall comparable in terms of the composite of clinically relevant device-related complications and inappropriate shock.
Collapse
Affiliation(s)
- Roberto Rordorf
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy.
| | - Matteo Casula
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy; Department of Molecular Medicine, Unit of Cardiology, University of Pavia, Pavia, Italy
| | - Laura Pezza
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy; Department of Molecular Medicine, Unit of Cardiology, University of Pavia, Pavia, Italy
| | - Federico Fortuni
- Department of Molecular Medicine, Unit of Cardiology, University of Pavia, Pavia, Italy
| | - Antonio Sanzo
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy
| | - Simone Savastano
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy
| | - Alessandro Vicentini
- Cardiac Intensive Care Unit, Arrhythmia and Electrophysiology and Experimental Cardiology, IRCCS Fondazione Policlinico S. Matteo, Pavia, Italy
| |
Collapse
|
46
|
Cheng Z. Left ventricular midwall fibrosis as a predictor of sudden cardiac death in non-ischemic dilated cardiomyopathy: A meta-analysis. J Cardiovasc Electrophysiol 2020; 32:169. [PMID: 33135224 DOI: 10.1111/jce.14797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 10/28/2020] [Accepted: 10/28/2020] [Indexed: 02/05/2023]
Affiliation(s)
- Zeyi Cheng
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
47
|
Willy K, Reinke F, Rath B, Ellermann C, Wolfes J, Bögeholz N, Köbe J, Eckardt L, Frommeyer G. Pitfalls of the S-ICD therapy: experiences from a large tertiary centre. Clin Res Cardiol 2020; 110:861-867. [PMID: 33130912 PMCID: PMC8166696 DOI: 10.1007/s00392-020-01767-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 10/15/2020] [Indexed: 11/25/2022]
Abstract
Aim The subcutaneous ICD (S-ICD) has evolved to a potential first option for many patients who have to be protected from sudden cardiac death. Many trials have underlined a similar performance regarding its effectiveness in relation to transvenous ICDs and have shown the expected benefits concerning infective endocarditis and lead failure. However, there have also been problems due to the peculiarities of the device, such as oversensing and myopotentials. In this study, we present patients from a large tertiary centre suffering from complications with an S-ICD and propose possible solutions. Methods and results All S-ICD patients who experienced complications related to the device (n = 40) of our large-scale single-centre S-ICD registry (n = 351 patients) were included in this study. Baseline characteristics, complications occurring and solutions to these problems were documented over a mean follow-up of 50 months. In most cases (n = 23), patients suffered from oversensing (18 cases with T wave or P wave oversensing, 5 due to myopotentials). Re-programming successfully prevented further oversensing episode in 13/23 patients. In 9 patients, generator or lead-related complications, mostly due to infectious reasons (5/9), occurred. Further problems consisted of ineffective shocks in one patient and need for antibradycardia stimulation in 2 patients and indication for CRT in 2 other patients. In total, the S-ICD had to be extracted in 10 patients. 7 of them received a tv-ICD subsequently, 3 patients refused re-implantation of any ICD. One other patient kept the ICD but had antitachycardic therapy deactivated due to inappropriate shocks for myopotential oversensing. Conclusion The S-ICD is a valuable option for many patients for the prevention of sudden cardiac death. Nonetheless, certain problems are immanent to the S-ICD (limited re-programming options, size of the generator) and should be addressed in future generations of the S-ICD. Graphic abstract ![]()
Collapse
Affiliation(s)
- Kevin Willy
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany.
| | - Florian Reinke
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Benjamin Rath
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Christian Ellermann
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Julian Wolfes
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Nils Bögeholz
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Julia Köbe
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Lars Eckardt
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| | - Gerrit Frommeyer
- Clinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
| |
Collapse
|
48
|
Gold MR, Lambiase PD, El-Chami MF, Knops RE, Aasbo JD, Bongiorni MG, Russo AM, Deharo JC, Burke MC, Dinerman J, Barr CS, Shaik N, Carter N, Stoltz T, Stein KM, Brisben AJ, Boersma LVA. Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial. Circulation 2020; 143:7-17. [PMID: 33073614 PMCID: PMC7752215 DOI: 10.1161/circulationaha.120.048728] [Citation(s) in RCA: 128] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Supplemental Digital Content is available in the text. Background: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. Results: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.
Collapse
Affiliation(s)
- Michael R Gold
- Department of Medicine, Medical University of South Carolina, Charleston (M.R.G.)
| | - Pier D Lambiase
- Institute of Cardiovascular Science, University College of London, Barts Heart Centre and University College, London, United Kingdom (P.D.L.)
| | | | - Reinoud E Knops
- Department of Electrophysiology, Amsterdam University Medical Center, The Netherlands (R.E.K.)
| | - Johan D Aasbo
- Department of Cardiac Electrophysiology, Baptist Health Lexington, KY (J.D.A.)
| | | | - Andrea M Russo
- Department of Medicine, Cooper Medical School of Rowan University, Camden, NJ (A.M.R.)
| | - Jean-Claude Deharo
- Cardiologie and Rythmologie Division, Centre hospitalier Universitaire La Timone Hospital, Marseille, France (J.C.D.)
| | | | - Jay Dinerman
- Heart Center Research, LLC, Huntsville, AL (J.D.)
| | - Craig S Barr
- Russells Hall Hospital, Dudley, United Kingdom (C.S.B.)
| | | | - Nathan Carter
- Boston Scientific Corporation, St Paul, MN (N,C., T.S., K.M.S., A.J.B.)
| | - Thomas Stoltz
- Boston Scientific Corporation, St Paul, MN (N,C., T.S., K.M.S., A.J.B.)
| | - Kenneth M Stein
- Boston Scientific Corporation, St Paul, MN (N,C., T.S., K.M.S., A.J.B.)
| | - Amy J Brisben
- Boston Scientific Corporation, St Paul, MN (N,C., T.S., K.M.S., A.J.B.)
| | - Lucas V A Boersma
- St Antonius Ziekenhuis, Nieuwegein Department of Cardiology, Nieuwegein, The Netherlands (L.V.B.)
| | | |
Collapse
|
49
|
Mitacchione G, Schiavone M, Gasperetti A, Viecca M, Curnis A, Forleo GB. Neglected lead tip erosion: An unusual case of S‐ICD inappropriate shock. J Cardiovasc Electrophysiol 2020; 31:3322-3325. [DOI: 10.1111/jce.14746] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 09/11/2020] [Accepted: 09/14/2020] [Indexed: 11/27/2022]
Affiliation(s)
| | - Marco Schiavone
- Department of Cardiology Luigi Sacco University Hospital Milan Italy
| | | | - Maurizio Viecca
- Department of Cardiology Luigi Sacco University Hospital Milan Italy
| | - Antonio Curnis
- Department of Cardiology Spedali Civili Hospital University of Brescia Brescia Italy
| | | |
Collapse
|
50
|
Steffel J. The subcutaneous ICD for prevention of sudden cardiac death: Current evidence and future directions. Pacing Clin Electrophysiol 2020; 43:1421-1427. [PMID: 32896919 DOI: 10.1111/pace.14066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 08/20/2020] [Accepted: 09/06/2020] [Indexed: 11/30/2022]
Abstract
Despite major advances in medical therapy, sudden cardiac death remains an important cause of cardiovascular mortality. In order to improve the risk-benefit balance of transvenous implantable cardioverter-defibrillator (ICD) systems, a totally subcutaneous ICD (S-ICD) system was developed and approved for use in Europe in 2009. The currently available S-ICD system has undergone several important hardware- and software-related modifications and improvements over the last 10 years aimed at further improving its efficacy and safety. The results of the PRAETORIAN trial, that is, the first randomized comparison of S-ICD versus transvenous ICDs, of the prospective UNTOUCHED study, and the overall consistent observational data underline that current generation S-ICD systems may be a valid alternative in patients with an ICD indication in whom bradycardia pacing or cardiac resynchronization therapy is not required due to a lower risk of system-related problems. This review summarizes the key differences between the two systems, improvements in hardware components and algorithms over time, as well as most recent clinical evidence regarding the efficacy and safety of the S-ICD.
Collapse
Affiliation(s)
- Jan Steffel
- Division of Electrophysiology and Cardiac Devices, Department of Cardiology, University Heart Center Zurich, Zurich, Switzerland
| |
Collapse
|