1
|
Chu CS, Chang CH, Pan CC, Chiang YC, Kuo HY, Hsu TW, Chen SL, Chen CS. Effect of cranial electrotherapy stimulation as an add-on therapy on late-life generalized anxiety disorder: An open-label study. J Formos Med Assoc 2024; 123:781-787. [PMID: 38485555 DOI: 10.1016/j.jfma.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/19/2023] [Accepted: 12/04/2023] [Indexed: 06/23/2024] Open
Abstract
INTRODUCTION Cranial electrotherapy stimulation (CES) is beneficial in reducing anxiety in psychiatric patients. However, no studies have reported on elderly patients with generalized anxiety disorders (GAD). This study aimed to determine the efficacy and safety of a 6-week CES intervention for late-life GAD. MATERIALS AND METHODS This single-arm pilot study assessed 6-week CES treatment (Alpha-Stim AID) for late-life GAD and 4-week follow-up post intervention. The Hamilton Rating Scale for Anxiety (HAMA) and Beck Anxiety Inventory (BAI) were used as baseline and outcome measures at weeks 4, 6, and 10, respectively. Treatment response was defined as 50 % or more reduction of the HAMA score and remission was defined as a of score ≤7 on the HAMA. Other measures included depression, sleep quality, and quality of life assessment. RESULTS We included participants (n = 27) aged 68.0 ± 5.0 years, 81.5 % of whom were female. Fifteen (55.6 %), 18 (66.7 %), and 15 (55.6 %) patients were concurrently treated with antidepressants, BZDs, and antipsychotics, respectively. Intention-to-treat (ITT) analysis revealed a significant decrease in HAMA scores from baseline (20.96 ± 3.30) to week 6 (12.26 ± 7.09) and one-month (12.85 ± 7.08) follow-up at W10 (all p < 0.001). The response and remission rates were 33.3 %, 40.7 %, and 48.1 % and 25.9 %, 29.6 %, and 25.9 % at W4, W6, and W10, respectively. The CES improved depression and sleep conditions as measured by the Beck Depression Inventory-II and Pittsburgh Sleep Quality Index. CONCLUSION CES clinically reduces symptoms of anxiety and depression and may improve sleep quality in late-life GAD. Future randomized controlled study is needed.
Collapse
Affiliation(s)
- Che-Sheng Chu
- Department of Psychiatry, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan; Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Center for Geriatrics and Gerontology, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan; Non-invasive Neuromodulation Consortium for Mental Disorders, Society of Psychophysiology, Taipei, Taiwan
| | - Cheng-Ho Chang
- Department of Psychiatry, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Chih-Chuan Pan
- Department of Psychiatry, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Yung-Chih Chiang
- Department of Psychiatry, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Hsin-Ya Kuo
- Department of Psychiatry, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Tien-Wei Hsu
- Department of Psychiatry, E-Da Dachang Hospital, I-Shou University, Kaohsiung, Taiwan
| | - Shiou-Lan Chen
- Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Drug Development and Value Creation Research Center and MSc Program in Tropical Medicine, Department of Medicine Research, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan; College of Professional Studies, National Pingtung University, Pingtung, Taiwan
| | - Cheng-Sheng Chen
- Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Psychiatry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan; Department of Psychiatry, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
| |
Collapse
|
2
|
Lee M, Kim Y, Yoon IY, Hong JK. Effects of cranial electrotherapy stimulation on improving depressive symptoms in people with stress: A randomized, double-blind controlled study. J Affect Disord 2023; 340:835-842. [PMID: 37598716 DOI: 10.1016/j.jad.2023.08.062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/18/2023] [Accepted: 08/11/2023] [Indexed: 08/22/2023]
Abstract
BACKGROUND Cranial electrotherapy stimulation (CES) is a form of neurostimulation that delivers alternating microcurrent via electrodes on the head. We investigated the effectiveness of CES in reducing stress. METHODS Participants who experienced subjective stress combined with subclinical depression or insomnia were recruited based on interviews and questionnaires. The subjects were randomly assigned to the active CES or sham groups and asked to use the device for 30 min twice a day for three weeks. Psychological rating scales, quantitative electroencephalography (QEEG), and serial salivary cortisol levels were measured before and after the intervention. RESULTS Sixty-two participants (58 females, mean age = 47.3 ± 8.2 years) completed the trial. After intervention, the depression scores improved significantly to a nearly normal level (Beck depression inventory-II, 31.3 ± 11.6 to 10.8 ± 7.2, p < 0.001) in the CES group, which were greater improvement compared to the sham group (p = 0.020). There were significant group-by-visit interactions in absolute delta power in the temporal area (p = 0.033), and theta (p = 0.038), beta (p = 0.048), and high beta power (p = 0.048) in the parietal area. CES led to a flattening of the cortisol slope (p = 0.011) and an increase in bedtime cortisol (p = 0.036) compared to the sham group. LIMITATIONS Bias may have been introduced during the process because device use and sample collection were self-conducted by participants at home. CONCLUSIONS CES can alleviate depressive symptoms and stress response, showing a potential as an adjunctive therapy for stress.
Collapse
Affiliation(s)
- Minji Lee
- Department of Neuropsychiatry, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea
| | - Yuna Kim
- Department of Neuropsychiatry, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea
| | - In-Young Yoon
- Department of Neuropsychiatry, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea; Department of Psychiatry, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Jung Kyung Hong
- Department of Neuropsychiatry, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea; Department of Psychiatry, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
| |
Collapse
|
3
|
Petrossian G, Kateb P, Miquet-Westphal F, Cicoira F. Advances in Electrode Materials for Scalp, Forehead, and Ear EEG: A Mini-Review. ACS APPLIED BIO MATERIALS 2023; 6:3019-3032. [PMID: 37493408 DOI: 10.1021/acsabm.3c00322] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2023]
Abstract
Electroencephalogram (EEG) records the electrical activity of neurons in the cerebral cortex and is used extensively to diagnose, treat, and monitor psychiatric and neurological conditions. Reliable contact between the skin and the electrodes is essential for achieving consistency and for obtaining electroencephalographic information. There has been an increasing demand for effective equipment and electrodes to overcome the time-consuming and cumbersome application of traditional systems. Recently, ear-centered EEG has met with growing interest since it can provide good signal quality due to the proximity of the ear to the brain. In addition, it can facilitate mobile and unobtrusive usage due to its smaller size and ease of use, since it can be used without interfering with the patient's daily activities. The purpose of this mini-review is to first introduce the broad range of electrodes used in conventional (scalp) EEG and subsequently discuss the state-of-the-art literature about around- and in-the-ear EEG.
Collapse
Affiliation(s)
- Gayaneh Petrossian
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| | - Pierre Kateb
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| | | | - Fabio Cicoira
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| |
Collapse
|
4
|
McGowan AL, Sayed F, Boyd ZM, Jovanova M, Kang Y, Speer ME, Cosme D, Mucha PJ, Ochsner KN, Bassett DS, Falk EB, Lydon-Staley DM. Dense Sampling Approaches for Psychiatry Research: Combining Scanners and Smartphones. Biol Psychiatry 2023; 93:681-689. [PMID: 36797176 PMCID: PMC10038886 DOI: 10.1016/j.biopsych.2022.12.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 11/22/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
Together, data from brain scanners and smartphones have sufficient coverage of biology, psychology, and environment to articulate between-person differences in the interplay within and across biological, psychological, and environmental systems thought to underlie psychopathology. An important next step is to develop frameworks that combine these two modalities in ways that leverage their coverage across layers of human experience to have maximum impact on our understanding and treatment of psychopathology. We review literature published in the last 3 years highlighting how scanners and smartphones have been combined to date, outline and discuss the strengths and weaknesses of existing approaches, and sketch a network science framework heretofore underrepresented in work combining scanners and smartphones that can push forward our understanding of health and disease.
Collapse
Affiliation(s)
- Amanda L McGowan
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Psychology, Concordia University, Montréal, Québec, Canada
| | - Farah Sayed
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Zachary M Boyd
- Department of Mathematics, Brigham Young University, Provo, Utah
| | - Mia Jovanova
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Yoona Kang
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Megan E Speer
- Department of Psychology, Columbia University, New York, New York
| | - Danielle Cosme
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Peter J Mucha
- Department of Mathematics, Dartmouth College, Hanover, New Hampshire
| | - Kevin N Ochsner
- Department of Psychology, Columbia University, New York, New York
| | - Dani S Bassett
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Physics & Astronomy, College of Arts and Sciences, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Electrical & Systems Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania; Santa Fe Institute, Santa Fe, New Mexico
| | - Emily B Falk
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Psychology, University of Pennsylvania, Philadelphia, Pennsylvania; Marketing Department, Wharton School, University of Pennsylvania, Philadelphia, Pennsylvania; Operations, Information and Decisions, Wharton School, University of Pennsylvania, Philadelphia, Pennsylvania
| | - David M Lydon-Staley
- Annenberg School for Communication, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania; Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, Pennsylvania.
| |
Collapse
|
5
|
Dai Y, Qin Q, Chen B, Chen L, Sun Q, Vgontzas AN, Basta M, Li Y. Effects of electrostatic therapy on nighttime sleep and daytime symptoms in patients with chronic insomnia: Evidences from an open label study. Front Neurosci 2023; 16:1047240. [PMID: 36685220 PMCID: PMC9853294 DOI: 10.3389/fnins.2022.1047240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Accepted: 12/09/2022] [Indexed: 01/07/2023] Open
Abstract
Introduction Transcranial electric stimulation (TES) is a neuromodulation approach that applies low-intensity electrical current to the brain and has been proposed as a treatment for insomnia. Electrostatic therapy is a kind of TES and people do not have a feeling of electrical stimuli when the voltage of static electricity is lower than 2,000 volts. However, no studies have examined the effects of electrostatic therapy on objective sleep and daytime symptoms in patients with insomnia. Materials and methods Thirty chronic insomnia patients were included. All patients received a 6 week electrostatic therapy and three comprehensive assessments including two consecutive polysomnography (PSG) and daytime symptoms assessments, at pre-treatment, 3 week and 6 week of treatment. Insomnia Severity Index (ISI) was used to assess the severity of insomnia. Multiple sleep latency test (MSLT), Epworth Sleepiness Scale (ESS), and Flinders Fatigue Scale (FFS) were used to assess objective and self-reported daytime sleepiness and fatigue, respectively. Attention network test (ANT) was used to assess attention levels. Results Total ISI scores decreased significantly at 3 weeks (p < 0.001) and 6 weeks (p < 0.001) after initiation of treatment. Furthermore, objective total sleep time (TST, p = 0.020) and sleep efficiency (SE, p = 0.009) increased and wake time after sleep onset (p = 0.012) decreased significantly after 6 weeks electrostatic therapy. Regarding daytime symptoms, ESS and FFS scores decreased significantly at 3 weeks (ESS, p = 0.047; FFS, p = 0.017) and 6 weeks (ESS, p = 0.008; FFS, p = 0.003) after initiation of treatment. Moreover, executive control improved significantly from pre-treatment to 3 weeks (p = 0.006) and 6 weeks (p = 0.013) and altering network improved significantly at 6 weeks (p = 0.003) after initiation of treatment. Secondary analyses showed that TST and SE improved significantly after electrostatic therapy in insomnia patients who slept < 390 min (all p-value < 0.05). However, no significant changes regarding TST and SE were observed in insomnia patients who slept ≥ 390 min. Conclusion Electrostatic therapy improves both nighttime sleep and daytime symptoms in patients with chronic insomnia. The effect on objective sleep appears to be stronger in patient with objective short sleep duration. Electrostatic therapy might be a therapeutic choice for insomnia patients with difficulty maintaining sleep and not responding to behavioral treatments. Clinical trial registration [www.clinicaltrials.gov], identifier [ChiCTR2100051590].
Collapse
Affiliation(s)
- Yanyuan Dai
- Department of Sleep Medicine, Shantou University Mental Health Center, Shantou University Medical College, Shantou, Guangdong, China
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| | - Qingsong Qin
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| | - Baixin Chen
- Department of Sleep Medicine, Shantou University Mental Health Center, Shantou University Medical College, Shantou, Guangdong, China
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| | - Le Chen
- Department of Sleep Medicine, Shantou University Mental Health Center, Shantou University Medical College, Shantou, Guangdong, China
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| | - Qimeng Sun
- Department of Sleep Medicine, Shantou University Mental Health Center, Shantou University Medical College, Shantou, Guangdong, China
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| | - Alexandros N. Vgontzas
- Department of Psychiatry, Sleep Research and Treatment Center, College of Medicine, The Pennsylvania State University, Hershey, PA, United States
| | - Maria Basta
- Department of Psychiatry, University Hospital of Heraklion, Heraklion, Greece
| | - Yun Li
- Department of Sleep Medicine, Shantou University Mental Health Center, Shantou University Medical College, Shantou, Guangdong, China
- Sleep Medicine Center, Shantou University Medical College, Shantou, Guangdong, China
| |
Collapse
|
6
|
Chung FC, Sun CK, Chen Y, Cheng YS, Chung W, Tzang RF, Chiu HJ, Wang MY, Cheng YC, Hung KC. Efficacy of electrical cranial stimulation for treatment of psychiatric symptoms in patients with anxiety: A systematic review and meta-analysis. Front Psychiatry 2023; 14:1157473. [PMID: 37091717 PMCID: PMC10115990 DOI: 10.3389/fpsyt.2023.1157473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 03/23/2023] [Indexed: 04/25/2023] Open
Abstract
Background Therapeutic effects of electrical cranial stimulation (CES) in patients suffering from anxiety remained unclear. This meta-analysis aimed at investigating acceptability and therapeutic efficacy of CES against anxiety, depression, and insomnia for patients who experienced symptoms of anxiety. Methods Major electronic databases were searched from inception until December 10, 2022 for randomized controlled trials (RCT) focusing on therapeutic effectiveness of CES in patients whose primary complaints included anxiety. Effect sizes (ES) for different treatment outcomes were estimated by using generic inverse variance method. Results Eight RCTs were identified including a total of 337 participants. The therapeutic effectiveness of CES was significantly better than that in the control groups for anxiety (ES=-0.96, p <0.00001, eight trials, 337 patients), depression (ES=-0.69, p=0.003, five trials), and insomnia (ES=-1.02, p = 0.0006, three trials) in those who presented with symptoms of anxiety. Subgroup analyses found that CES was equally effective regardless of comorbid presentation of depressive symptoms (ES=-0.94 in patients with anxiety only vs. ES=-1.06 in those with depression and anxiety) and whether CES was used as monotherapy or add-on therapy to medications (ES = -0.88 vs. ES = -1.12, respectively). Moreover, subgroup analysis of RCTs using the same device "Alpha-Stim" for CES was more effective in alleviating anxiety than sham controls (ES = -0.88, p < 0.00001, four trials, 230 patients). Regarding acceptability, the use of CES did not increase the risk of treatment-related dropout compared to the control group (RR = 1.26, p = 0.57, I2 = 0%, four trials, 324 patients). Conclusion Our study supported the use of CES for symptoms of anxiety, depression, and insomnia in those suffering from anxiety with fair acceptability and demonstrated the efficacy of "Alpha-Stim", the most commonly used device for CES, in this patient population. Systematic review registration https://www.crd.york.ac.uk/prospero/, identifier: CRD42022382619.
Collapse
Affiliation(s)
- Feng-Chin Chung
- Department of Psychiatry, Tsyr-Huey Mental Hospital, Kaohsiung Jen-Ai's Home, Kaohsiung, Taiwan
| | - Cheuk-Kwan Sun
- Department of Emergency Medicine, E-Da Hospital, I-Shou University, Kaohsiung City, Taiwan
- College of Medicine, School of Medicine for International Students, I-Shou University, Kaohsiung, Taiwan
| | - Yi Chen
- Department of Psychiatry, Tsyr-Huey Mental Hospital, Kaohsiung Jen-Ai's Home, Kaohsiung, Taiwan
| | - Yu-Shian Cheng
- Department of Psychiatry, Tsyr-Huey Mental Hospital, Kaohsiung Jen-Ai's Home, Kaohsiung, Taiwan
| | - Weilun Chung
- Department of Psychiatry, Tsyr-Huey Mental Hospital, Kaohsiung Jen-Ai's Home, Kaohsiung, Taiwan
| | - Ruu-Fen Tzang
- Department of Psychiatry, Mackay Memorial Hospital, Taipei, Taiwan
| | - Hsien-Jane Chiu
- Taoyuan Psychiatric Center, Ministry of Health and Welfare, Taoyuan, Taiwan
- Institute of Hospital and Health Care Administration, National Yang-Ming Chiao Tung University, Taipei, Taiwan
| | - Ming-Yu Wang
- Department of Psychiatry, China Medical University Hsinchu Hospital, China Medical University, Hsinchu, Taiwan
- Department of Health Services Administration, China Medical University, Taichung, Taiwan
| | - Ying-Chih Cheng
- Department of Psychiatry, China Medical University Hsinchu Hospital, China Medical University, Hsinchu, Taiwan
- College of Public Health, National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei, Taiwan
- Research Center of Big Data and Meta-Analysis, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan
| | - Kuo-Chuan Hung
- College of Medicine, School of Medicine, National Sun Yat-sen University, Kaohsiung, Taiwan
- Department of Anesthesiology, Chi Mei Medical Center, Tainan, Taiwan
- *Correspondence: Kuo-Chuan Hung
| |
Collapse
|