1
|
El-Nashar H, Sabry M, Tseng YT, Francis N, Latif N, Parker KH, Moore JE, Yacoub MH. Multiscale structure and function of the aortic valve apparatus. Physiol Rev 2024; 104:1487-1532. [PMID: 37732828 DOI: 10.1152/physrev.00038.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 08/30/2023] [Accepted: 09/01/2023] [Indexed: 09/22/2023] Open
Abstract
Whereas studying the aortic valve in isolation has facilitated the development of life-saving procedures and technologies, the dynamic interplay of the aortic valve and its surrounding structures is vital to preserving their function across the wide range of conditions encountered in an active lifestyle. Our view is that these structures should be viewed as an integrated functional unit, here referred to as the aortic valve apparatus (AVA). The coupling of the aortic valve and root, left ventricular outflow tract, and blood circulation is crucial for AVA's functions: unidirectional flow out of the left ventricle, coronary perfusion, reservoir function, and support of left ventricular function. In this review, we explore the multiscale biological and physical phenomena that underlie the simultaneous fulfillment of these functions. A brief overview of the tools used to investigate the AVA, such as medical imaging modalities, experimental methods, and computational modeling, specifically fluid-structure interaction (FSI) simulations, is included. Some pathologies affecting the AVA are explored, and insights are provided on treatments and interventions that aim to maintain quality of life. The concepts explained in this article support the idea of AVA being an integrated functional unit and help identify unanswered research questions. Incorporating phenomena through the molecular, micro, meso, and whole tissue scales is crucial for understanding the sophisticated normal functions and diseases of the AVA.
Collapse
Affiliation(s)
- Hussam El-Nashar
- Aswan Heart Research Centre, Magdi Yacoub Foundation, Cairo, Egypt
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Malak Sabry
- Aswan Heart Research Centre, Magdi Yacoub Foundation, Cairo, Egypt
- Department of Biomedical Engineering, King's College London, London, United Kingdom
| | - Yuan-Tsan Tseng
- Heart Science Centre, Magdi Yacoub Institute, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Nadine Francis
- Aswan Heart Research Centre, Magdi Yacoub Foundation, Cairo, Egypt
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Najma Latif
- Heart Science Centre, Magdi Yacoub Institute, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Kim H Parker
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - James E Moore
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Magdi H Yacoub
- Aswan Heart Research Centre, Magdi Yacoub Foundation, Cairo, Egypt
- Heart Science Centre, Magdi Yacoub Institute, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| |
Collapse
|
2
|
Notenboom ML, Van Hoof L, Schuermans A, Takkenberg JJM, Rega FR, Taverne YJHJ. Aortic Valve Embryology, Mechanobiology, and Second Messenger Pathways: Implications for Clinical Practice. J Cardiovasc Dev Dis 2024; 11:49. [PMID: 38392263 PMCID: PMC10888685 DOI: 10.3390/jcdd11020049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 01/22/2024] [Accepted: 01/29/2024] [Indexed: 02/24/2024] Open
Abstract
During the Renaissance, Leonardo Da Vinci was the first person to successfully detail the anatomy of the aortic root and its adjacent structures. Ever since, novel insights into morphology, function, and their interplay have accumulated, resulting in advanced knowledge on the complex functional characteristics of the aortic valve (AV) and root. This has shifted our vision from the AV as being a static structure towards that of a dynamic interconnected apparatus within the aortic root as a functional unit, exhibiting a complex interplay with adjacent structures via both humoral and mechanical stimuli. This paradigm shift has stimulated surgical treatment strategies of valvular disease that seek to recapitulate healthy AV function, whereby AV disease can no longer be seen as an isolated morphological pathology which needs to be replaced. As prostheses still cannot reproduce the complexity of human nature, treatment of diseased AVs, whether stenotic or insufficient, has tremendously evolved, with a similar shift towards treatments options that are more hemodynamically centered, such as the Ross procedure and valve-conserving surgery. Native AV and root components allow for an efficient Venturi effect over the valve to allow for optimal opening during the cardiac cycle, while also alleviating the left ventricle. Next to that, several receptors are present on native AV leaflets, enabling messenger pathways based on their interaction with blood and other shear-stress-related stimuli. Many of these physiological and hemodynamical processes are under-acknowledged but may hold important clues for innovative treatment strategies, or as potential novel targets for therapeutic agents that halt or reverse the process of valve degeneration. A structured overview of these pathways and their implications for cardiothoracic surgeons and cardiologists is lacking. As such, we provide an overview on embryology, hemodynamics, and messenger pathways of the healthy and diseased AV and its implications for clinical practice, by relating this knowledge to current treatment alternatives and clinical decision making.
Collapse
Affiliation(s)
- Maximiliaan L Notenboom
- Department of Cardiothoracic Surgery, Erasmus University Medical Center, 3000 CA Rotterdam, The Netherlands
| | - Lucas Van Hoof
- Department of Cardiac Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
| | - Art Schuermans
- Department of Cardiac Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
| | - Johanna J M Takkenberg
- Department of Cardiothoracic Surgery, Erasmus University Medical Center, 3000 CA Rotterdam, The Netherlands
| | - Filip R Rega
- Department of Cardiac Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
| | - Yannick J H J Taverne
- Department of Cardiothoracic Surgery, Erasmus University Medical Center, 3000 CA Rotterdam, The Netherlands
| |
Collapse
|
3
|
Biomechanics of Pulmonary Autograft as Living Tissue: A Systematic Review. Bioengineering (Basel) 2022; 9:bioengineering9090456. [PMID: 36135002 PMCID: PMC9495771 DOI: 10.3390/bioengineering9090456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/01/2022] [Accepted: 09/04/2022] [Indexed: 11/17/2022] Open
Abstract
Introduction: The choice of valve substitute for aortic valve surgery is tailored to the patient with specific indications and contraindications to consider. The use of an autologous pulmonary artery (PA) with a simultaneous homograft in the pulmonary position is called a Ross procedure. It permits somatic growth and the avoidance of lifelong anticoagulation. Concerns remain on the functionality of a pulmonary autograft in the aortic position when exposed to systemic pressure. Methods: A literature review was performed incorporating the following databases: Pub Med (1996 to present), Ovid Medline (1958 to present), and Ovid Embase (1982 to present), which was run on 1 January 2022 with the following targeted words: biomechanics of pulmonary autograft, biomechanics of Ross operation, aortic valve replacement and pulmonary autograph, aortic valve replacement and Ross procedure. To address the issues with heterogeneity, studies involving the pediatric cohort were also analyzed separately. The outcomes measured were early- and late-graft failure alongside mortality. Results: a total of 8468 patients were included based on 40 studies (7796 in pediatric cohort and young adult series and 672 in pediatric series). There was considerable experience accumulated by various institutions around the world. Late rates of biomechanical failure and mortality were low and comparable to the general population. The biomechanical properties of the PA were superior to other valve substitutes. Mathematical and finite element analysis studies have shown the potential stress-shielding effects of the PA root. Conclusion: The Ross procedure has excellent durability and longevity in clinical and biomechanical studies. The use of external reinforcements such as semi-resorbable scaffolds may further extend their longevity.
Collapse
|
4
|
Development of a bi-layered cryogenic electrospun polylactic acid scaffold to study calcific aortic valve disease in a 3D co-culture model. Acta Biomater 2022; 140:364-378. [PMID: 34839029 DOI: 10.1016/j.actbio.2021.11.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 10/27/2021] [Accepted: 11/22/2021] [Indexed: 11/23/2022]
Abstract
Calcified aortic valve disease (CAVD) is the most prevalent valve disease in the elderly. Targeted pharmacological therapies are limited since the underlying mechanisms of CAVD are not well understood. Appropriate 3D in vitro models could potentially improve our knowledge of the disease. Here, we developed a 3D in vitro aortic heart valve model that resembles the morphology of the valvular extracellular matrix and mimics the mechanical and physiological behavior of the native aortic valve fibrosa and spongiosa. We employed cryogenic electrospinning to engineer a bi-layered cryogenic electrospun scaffold (BCES) with defined morphologies that allowed valvular endothelial cell (VEC) adherence and valvular interstitial cell (VIC) ingrowth into the scaffold. Using a self-designed cell culture insert allowed us to establish the valvular co-culture simultaneously by seeding VICs on one side and VECs on the other side of the electrospun scaffold. Proof-of-principle calcification studies were successfully performed using an established osteogenic culture protocol and the here designed 3D in vitro aortic heart valve model. STATEMENT OF SIGNIFICANCE: Three-dimensional (3D) electrospun scaffolds are widely used for soft tissue engineering since they mimic the morphology of the native extracellular matrix. Several studies have shown that cells behave more naturally on 3D materials than on the commonly used stiff two-dimensional (2D) cell culture substrates, which have no biological properties. As appropriate 3D models for the study of aortic valve diseases are limited, we developed a novel bi-layered 3D in vitro test system by using the versatile technique of cryogenic electrospinning in combination with the influence of different solvents to mimic the morphology, mechanical, and cellular distribution of a native aortic heart valve leaflet. This 3D in vitro model can be used to study valve biology and heart valve-impacting diseases such as calcification to elucidate therapeutic targets.
Collapse
|
5
|
Van Hoof L, Verbrugghe P, Jones EAV, Humphrey JD, Janssens S, Famaey N, Rega F. Understanding Pulmonary Autograft Remodeling After the Ross Procedure: Stick to the Facts. Front Cardiovasc Med 2022; 9:829120. [PMID: 35224059 PMCID: PMC8865563 DOI: 10.3389/fcvm.2022.829120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 01/17/2022] [Indexed: 12/12/2022] Open
Abstract
The Ross, or pulmonary autograft, procedure presents a fascinating mechanobiological scenario. Due to the common embryological origin of the aortic and pulmonary root, the conotruncus, several authors have hypothesized that a pulmonary autograft has the innate potential to remodel into an aortic phenotype once exposed to systemic conditions. Most of our understanding of pulmonary autograft mechanobiology stems from the remodeling observed in the arterial wall, rather than the valve, simply because there have been many opportunities to study the walls of dilated autografts explanted at reoperation. While previous histological studies provided important clues on autograft adaptation, a comprehensive understanding of its determinants and underlying mechanisms is needed so that the Ross procedure can become a widely accepted aortic valve substitute in select patients. It is clear that protecting the autograft during the early adaptation phase is crucial to avoid initiating a sequence of pathological remodeling. External support in the freestanding Ross procedure should aim to prevent dilatation while simultaneously promoting remodeling, rather than preventing dilatation at the cost of vascular atrophy. To define the optimal mechanical properties and geometry for external support, the ideal conditions for autograft remodeling and the timeline of mechanical adaptation must be determined. We aimed to rigorously review pulmonary autograft remodeling after the Ross procedure. Starting from the developmental, microstructural and biomechanical differences between the pulmonary artery and aorta, we review autograft mechanobiology in relation to distinct clinical failure mechanisms while aiming to identify unmet clinical needs, gaps in current knowledge and areas for further research. By correlating clinical and experimental observations of autograft remodeling with established principles in cardiovascular mechanobiology, we aim to present an up-to-date overview of all factors involved in extracellular matrix remodeling, their interactions and potential underlying molecular mechanisms.
Collapse
Affiliation(s)
- Lucas Van Hoof
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Peter Verbrugghe
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | | | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Stefan Janssens
- Department of Cardiology, University Hospitals Leuven, Leuven, Belgium
| | - Nele Famaey
- Biomechanics Section, KU Leuven, Leuven, Belgium
| | - Filip Rega
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
6
|
Tandon I, Ozkizilcik A, Ravishankar P, Balachandran K. Aortic valve cell microenvironment: Considerations for developing a valve-on-chip. BIOPHYSICS REVIEWS 2021; 2:041303. [PMID: 38504720 PMCID: PMC10903420 DOI: 10.1063/5.0063608] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/15/2021] [Indexed: 03/21/2024]
Abstract
Cardiac valves are sophisticated, dynamic structures residing in a complex mechanical and hemodynamic environment. Cardiac valve disease is an active and progressive disease resulting in severe socioeconomic burden, especially in the elderly. Valve disease also leads to a 50% increase in the possibility of associated cardiovascular events. Yet, valve replacement remains the standard of treatment with early detection, mitigation, and alternate therapeutic strategies still lacking. Effective study models are required to further elucidate disease mechanisms and diagnostic and therapeutic strategies. Organ-on-chip models offer a unique and powerful environment that incorporates the ease and reproducibility of in vitro systems along with the complexity and physiological recapitulation of the in vivo system. The key to developing effective valve-on-chip models is maintaining the cell and tissue-level microenvironment relevant to the study application. This review outlines the various components and factors that comprise and/or affect the cell microenvironment that ought to be considered while constructing a valve-on-chip model. This review also dives into the advancements made toward constructing valve-on-chip models with a specific focus on the aortic valve, that is, in vitro studies incorporating three-dimensional co-culture models that incorporate relevant extracellular matrices and mechanical and hemodynamic cues.
Collapse
Affiliation(s)
- Ishita Tandon
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Asya Ozkizilcik
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Prashanth Ravishankar
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Kartik Balachandran
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| |
Collapse
|
7
|
Manduteanu I, Simionescu D, Simionescu A, Simionescu M. Aortic valve disease in diabetes: Molecular mechanisms and novel therapies. J Cell Mol Med 2021; 25:9483-9495. [PMID: 34561944 PMCID: PMC8505854 DOI: 10.1111/jcmm.16937] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 08/18/2021] [Accepted: 08/23/2021] [Indexed: 12/13/2022] Open
Abstract
Valve disease and particularly calcific aortic valve disease (CAVD) and diabetes (DM) are progressive diseases constituting a global health burden for all aging societies (Progress in Cardiovascular Diseases. 2014;56(6):565: Circulation Research. 2021;128(9):1344). Compared to non‐diabetic individuals (The Lancet. 2008;371(9626):1800: The American Journal of Cardiology. 1983;51(3):403: Journal of the American College of Cardiology. 2017;69(12):1523), the diabetic patients have a significantly greater propensity for cardiovascular disorders and faster degeneration of implanted bioprosthetic aortic valves. Previously, using an original experimental model, the diabetic‐hyperlipemic hamsters, we have shown that the earliest alterations induced by these conditions occur at the level of the aortic valves and, with time these changes lead to calcifications and CAVD. However, there are no pharmacological treatments available to reverse or retard the progression of aortic valve disease in diabetes, despite the significant advances in the field. Therefore, it is critical to uncover the mechanisms of valve disease progression, find biomarkers for diagnosis and new targets for therapies. This review aims at presenting an update on the basic research in CAVD in the context of diabetes. We provide an insight into the accumulated data including our results on diabetes‐induced progressive cell and molecular alterations in the aortic valve, new potential biomarkers to assess the evolution and therapy of the disease, advancement in targeted nanotherapies, tissue engineering and the potential use of circulating endothelial progenitor cells in CAVD.
Collapse
Affiliation(s)
- Ileana Manduteanu
- Institute of Cellular Biology and Pathology "Nicolae Simionescu" of the Romanian Academy, Bucharest, Romania
| | - Dan Simionescu
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Agneta Simionescu
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Maya Simionescu
- Institute of Cellular Biology and Pathology "Nicolae Simionescu" of the Romanian Academy, Bucharest, Romania
| |
Collapse
|
8
|
Koban R, Lam T, Schwarz F, Kloke L, Bürge S, Ellerbrok H, Neumann M. Simplified Bioprinting-Based 3D Cell Culture Infection Models for Virus Detection. Viruses 2020; 12:E1298. [PMID: 33198291 PMCID: PMC7698278 DOI: 10.3390/v12111298] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/04/2020] [Accepted: 11/10/2020] [Indexed: 12/13/2022] Open
Abstract
Studies of virus-host interactions in vitro may be hindered by biological characteristics of conventional monolayer cell cultures that differ from in vivo infection. Three-dimensional (3D) cell cultures show more in vivo-like characteristics and may represent a promising alternative for characterisation of infections. In this study, we established easy-to-handle cell culture platforms based on bioprinted 3D matrices for virus detection and characterisation. Different cell types were cultivated on these matrices and characterised for tissue-like growth characteristics regarding cell morphology and polarisation. Cells developed an in vivo-like morphology and long-term cultivation was possible on the matrices. Cell cultures were infected with viruses which differed in host range, tissue tropism, cytopathogenicity, and genomic organisation and virus morphology. Infections were characterised on molecular and imaging level. The transparent matrix substance allowed easy optical monitoring of cells and infection even via live-cell microscopy. In conclusion, we established an enhanced, standardised, easy-to-handle bioprinted 3D-cell culture system. The infection models are suitable for sensitive monitoring and characterisation of virus-host interactions and replication of different viruses under physiologically relevant conditions. Individual cell culture models can further be combined to a multicellular array. This generates a potent diagnostic tool for propagation and characterisation of viruses from diagnostic samples.
Collapse
Affiliation(s)
- Robert Koban
- Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany; (R.K.); (F.S.); (M.N.)
| | - Tobias Lam
- Cellbricks GmbH, Gustav-Meyer-Allee 25, 13355 Berlin, Germany; (T.L.); (L.K.)
| | - Franziska Schwarz
- Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany; (R.K.); (F.S.); (M.N.)
| | - Lutz Kloke
- Cellbricks GmbH, Gustav-Meyer-Allee 25, 13355 Berlin, Germany; (T.L.); (L.K.)
| | - Silvio Bürge
- Advanced Light and Electron Microscopy, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany;
| | - Heinz Ellerbrok
- Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany; (R.K.); (F.S.); (M.N.)
| | - Markus Neumann
- Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany; (R.K.); (F.S.); (M.N.)
| |
Collapse
|
9
|
de Oliveira DMC, Abdullah N, Green NC, Espino DM. Biomechanical Assessment of Bicuspid Aortic Valve Phenotypes: A Fluid-Structure Interaction Modelling Approach. Cardiovasc Eng Technol 2020; 11:431-447. [PMID: 32519086 DOI: 10.1007/s13239-020-00469-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 06/04/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE Bicuspid aortic valve (BAV) is a congenital heart malformation with phenotypic heterogeneity. There is no prior computational study that assesses the haemodynamic and valve mechanics associated with BAV type 2 against a healthy tricuspid aortic valve (TAV) and other BAV categories. METHODS A proof-of-concept study incorporating three-dimensional fluid-structure interaction (FSI) models with idealised geometries (one TAV and six BAVs, namely type 0 with lateral and anterior-posterior orientations, type 1 with R-L, N-R and N-L leaflet fusion and type 2) has been developed. Transient physiological boundary conditions have been applied and simulations were run using an Arbitrary Lagrangian-Eulerian formulation. RESULTS Our results showed the presence of abnormal haemodynamics in the aorta and abnormal valve mechanics: type 0 BAVs yielded the best haemodynamical and mechanical outcomes, but cusp stress distribution varied with valve orifice orientation, which can be linked to different cusp calcification location onset; type 1 BAVs gave rise to similar haemodynamics and valve mechanics, regardless of raphe position, but this position altered the location of abnormal haemodynamic features; finally, type 2 BAV constricted the majority of blood flow, exhibiting the most damaging haemodynamic and mechanical repercussions when compared to other BAV phenotypes. CONCLUSION The findings of this proof-of-concept work suggest that there are specific differences across haemodynamics and valve mechanics associated with BAV phenotypes, which may be critical to subsequent processes associated with their pathophysiology processes.
Collapse
Affiliation(s)
- Diana M C de Oliveira
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK.
| | - Nazirul Abdullah
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| | - Naomi C Green
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| | - Daniel M Espino
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| |
Collapse
|
10
|
Genotype-guided warfarin dosing may benefit patients with mechanical aortic valve replacements: randomized controlled study. Sci Rep 2020; 10:6988. [PMID: 32332930 PMCID: PMC7181853 DOI: 10.1038/s41598-020-63985-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 04/07/2020] [Indexed: 11/26/2022] Open
Abstract
This prospective, single-blind, randomized study was designed to evaluate the effect of genotype-based warfarin dosing compared with standard warfarin dosing in Korean patients with mechanical cardiac valves. Patients were assigned to either the genotype-based dosing group or the standard dosing group using stratified block randomization. The genotype-based dosing equation was adopted from a previous study which included VKORC1 rs9934438, CYP2C9 rs1057910, CYP4F2 rs2108622, and age. Primary outcomes included the percentage of time in the therapeutic range (pTTR): (i) during the first week following initiation of warfarin therapy, (ii) during hospitalization and (iii) until the first outpatient visit. A total of 91 patients were included in the analysis, 42 treated with genotype-based warfarin dosing and 49 treated with standard warfarin dosing. The genotype frequency differences of the three SNPs included in this study (ie, VKORC1, CYP2C9, CYP4F2), between the genotype-based dosing and standard dosing groups were not different. The genotype-based dosing group trended toward higher pTTR when compared with the standard dosing group, although this difference was not statistically significant. In patients with aortic valve replacement, TTRTraditional and TTRRosendaal were significantly higher in the genotype-based dosing group when compared with the standard dosing group during the first week following treatment initiation [ie, 58.5% vs. 38.1% (p = 0.009) and 64.0% vs. 44.6% (p = 0.012), respectively]. Based on the results, the genotype-guided dosing did not offer a significant clinical advantage, but a possible benefit in patients with aortic valve replacement has been suggested.
Collapse
|
11
|
Bik E, Mielniczek N, Jarosz M, Denbigh J, Budzynska R, Baranska M, Majzner K. Tunicamycin induced endoplasmic reticulum changes in endothelial cells investigated in vitro by confocal Raman imaging. Analyst 2020; 144:6561-6569. [PMID: 31576836 DOI: 10.1039/c9an01456j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This paper describes how tunicamycin (Tu), the most widely used pharmacological agent for inducing endoplasmic reticulum (ER) stress, interacts with endothelial cells. Our results show that tunicamycin enters the cells and accumulates within the ER area. ER stress takes place when improperly folded or damaged proteins begin to accumulate; however, spectroscopic markers of these changes have not been identified as yet. In this work, Raman spectroscopy and scanning electron microscopy imaging of individual endothelial cells treated with Tu were performed. The changes in the biochemical composition of endothelial cells induced by Tu attributed to ER stress were studied in detail. A main feature of the Tu impact on the cells was a decrease of the phospholipid content in the area of ER, and the most abundant lipid with phosphorus groups found there, was identified as sphingomyelin.
Collapse
Affiliation(s)
- Ewelina Bik
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, Krakow, Poland.
| | | | | | | | | | | | | |
Collapse
|
12
|
Affiliation(s)
- Magdi Yacoub
- Imperial College, Harefield Heart Science Centre, Harefield Hospital, Harefield, London, England, United Kingdom
| |
Collapse
|
13
|
Ibrahim M, Spelde AE, Carter TI, Patel PA, Desai N. The Ross Operation in the Adult: What, Why, and When? J Cardiothorac Vasc Anesth 2018. [DOI: 10.1053/j.jvca.2017.12.047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
14
|
Mohammadi H, Cartier R, Mongrain R. The impact of the aortic valve impairment on the distant coronary arteries hemodynamics: a fluid-structure interaction study. Med Biol Eng Comput 2017; 55:1859-1872. [PMID: 28316038 DOI: 10.1007/s11517-017-1636-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Accepted: 03/13/2017] [Indexed: 12/30/2022]
Abstract
Atherosclerosis is still the leading cause of death in the developed world. Although its initiation and progression is a complex multifactorial process, it is well known that blood flow-induced wall shear stress (WSS) is an important factor involved in early atherosclerotic plaque initiation. In recent clinical studies, it was established that the regional pathologies of the aortic valve can be involved in the formation of atherosclerotic plaques. However, the impact of hemodynamic effects is not yet fully elucidated for disease initiation and progression. In this study, our developed 3D global fluid-structure interaction model of the aortic root incorporating coronary arteries is used to investigate the possible interaction between coronary arteries and aortic valve pathologies. The coronary hemodynamics was examined and quantified for different degrees of aortic stenosis varying from nonexistent to severe. For the simulated healthy model, the calculated WSS varied between 0.41 and 1.34 Pa which is in the atheroprotective range. However, for moderate and severe aortic stenoses, wide regions of the coronary structures, especially the proximal sections around the first bifurcation, were exposed to lower values of WSS and therefore they were prone to atherosclerosis even in the case of healthy coronary arteries.
Collapse
Affiliation(s)
- Hossein Mohammadi
- Mechanical Engineering Department, McGill University, Montreal, QC, H3A 0C3, Canada
| | - Raymond Cartier
- Department of Cardiovascular Surgery, Montreal Heart Institute, Montreal, QC, H1T 1C8, Canada
| | - Rosaire Mongrain
- Mechanical Engineering Department, McGill University, Montreal, QC, H3A 0C3, Canada.
- Department of Cardiovascular Surgery, Montreal Heart Institute, Montreal, QC, H1T 1C8, Canada.
| |
Collapse
|
15
|
Towards the improved quantification of in vivo abnormal wall shear stresses in BAV-affected patients from 4D-flow imaging: Benchmarking and application to real data. J Biomech 2017; 50:93-101. [DOI: 10.1016/j.jbiomech.2016.11.044] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 11/02/2016] [Indexed: 01/15/2023]
|
16
|
Blancas AA, Balaoing LR, Acosta FM, Grande-Allen KJ. Identifying Behavioral Phenotypes and Heterogeneity in Heart Valve Surface Endothelium. Cells Tissues Organs 2016; 201:268-76. [PMID: 27144771 DOI: 10.1159/000444446] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/04/2016] [Indexed: 01/26/2023] Open
Abstract
Heart valvular endothelial cells (VECs) are distinct from vascular endothelial cells (ECs), but have an uncertain context within the spectrum of known endothelial phenotypes, including lymphatic ECs (LECs). Profiling the phenotypes of the heart valve surface VECs would facilitate identification of a proper seeding population for tissue-engineered valves, as well as elucidate mechanisms of valvular disease. Porcine VECs and porcine aortic ECs (AECs) were isolated from pig hearts and characterized to assess known EC and LEC markers. A transwell migration assay determined their propensity to migrate toward vascular endothelial growth factor, an angiogenic stimulus, over 24 h. Compared to AECs, Flt-1 was expressed on almost double the percentage of VECs, measured as 74 versus 38%. The expression of angiogenic EC markers CXCR4 and DLL4 was >90% on AECs, whereas VECs showed only 35% CXCR4+ and 47% DLL4+. AECs demonstrated greater migration (71.5 ± 11.0 cells per image field) than the VECs with 30.0 ± 15.3 cells per image field (p = 0.032). In total, 30% of VECs were positive for LYVE1+/Prox1+, while these markers were absent in AECs. In conclusion, the population of cells on the surface of heart valves is heterogeneous, consisting largely of nonangiogenic VECs and a subset of LECs. Previous studies have indicated the presence of LECs within the interior of the valves; however, this is the first study to demonstrate their presence on the surface. Identification of this unique endothelial mixture is a step forward in the development of engineered valve replacements as a uniform EC seeding population may not be the best option to maximize transplant success.
Collapse
|
17
|
Rozeik MM, Wheatley DJ, Gourlay T. The aortic valve: structure, complications and implications for transcatheter aortic valve replacement. Perfusion 2014; 29:285-300. [DOI: 10.1177/0267659114521650] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The aortic valve operates in a complex haemodynamic environment, opening and closing over 100,000 times a day. When complications arise, such as aortic stenosis, prognosis can be very poor, leading to death within the first few years. Surgical valve replacement is currently the standard treatment for aortic stenosis. A thorough understanding of the anatomy and function of the native valve is imperative when developing a prosthetic replacement that can withstand the complex demands of the heart. This review focuses on the anatomy, structure and disease of the aortic valve and the implications for a transcatheter aortic valve replacement (TAVR). Current complications with TAVR, such as major vascular bleeding, conduction disturbances and patient-prosthesis mismatch (PPM), can be overcome by reducing the delivery profile and through the use of more accurate imaging technologies to work towards a fully functional and durable prosthesis.
Collapse
Affiliation(s)
- MM Rozeik
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - DJ Wheatley
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - T Gourlay
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
18
|
Myles V, Liao J, Warnock JN. Cyclic pressure and angiotensin II influence the biomechanical properties of aortic valves. J Biomech Eng 2013; 136:011011. [PMID: 24240552 DOI: 10.1115/1.4026041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Indexed: 11/08/2022]
Abstract
Hypertension is a known risk factor for aortic stenosis. The elevated blood pressure increases the transvalvular load and can elicit inflammation and extracellular matrix (ECM) remodeling. Elevated cyclic pressure and the vasoactive agent angiotensin II (Ang II) both promote collagen synthesis, an early hallmark of aortic sclerosis. In the current study, it was hypothesized that elevated cyclic pressure and/or angiotensin II decreases extensibility of aortic valve leaflets due to an increase in collagen content and/or interstitial cell stiffness. Porcine aortic valve leaflets were exposed to pressure conditions of increasing magnitude (static atmospheric pressure, 80, and 120 mmHg) with and without 10−6 M Ang II. Biaxial mechanical testing was performed to determine extensibility in the circumferential and radial directions and collagen content was determined using a quantitative dye-binding method at 24 and 48 h. Isolated aortic valve interstitial cells exposed to the same experimental conditions were subjected to atomic force microscopy to assess cellular stiffness at 24 h. Leaflet tissue incubated with Ang II decreased tissue extensibility in the radial direction, but not in the circumferential direction. Elevated cyclic pressure decreased extensibility in both the radial and circumferential directions. Ang II and elevated cyclic pressure both increased the collagen content in leaflet tissue. Interstitial cells incubated with Ang II were stiffer than those incubated without Ang II while elevated cyclic pressure caused a decrease in cell stiffness. The results of the current study demonstrated that both pressure and Ang II play a role in altering the biomechanical properties of aortic valve leaflets. Ang II and elevated cyclic pressure decreased the extensibility of aortic valve leaflet tissue. Ang II induced direction specific changes in extensibility, demonstrating different response mechanisms. These findings help to provide a better understanding of the responses of aortic valves to mechanical and biochemical changes that occur under hypertensive conditions.
Collapse
|
19
|
Salinas M, Schmidt DE, Libera M, Lange RR, Ramaswamy S. Oscillatory shear stress created by fluid pulsatility versus flexed specimen configurations. Comput Methods Biomech Biomed Engin 2012; 17:728-39. [DOI: 10.1080/10255842.2012.715157] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
20
|
Therapeutic vascular compliance change may cause significant variation in coronary perfusion: a numerical study. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2012; 2012:791686. [PMID: 22474538 PMCID: PMC3303727 DOI: 10.1155/2012/791686] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2011] [Revised: 11/08/2011] [Accepted: 11/21/2011] [Indexed: 11/17/2022]
Abstract
In some pathological conditions like aortic stiffening and calcific aortic stenosis (CAS), the microstructure of the aortic root and the aortic valve leaflets are altered in response to stress resulting in changes in tissue thickness, stiffness, or both. This aortic stiffening and CAS are thought to affect coronary blood flow. The goal of the present paper was to include the flow in the coronary ostia in the previous fluid structure interaction model we have developed and to analyze the effect of diseased tissues (aortic root stiffening and CAS) on coronary perfusion. Results revealed a significant impact on the coronary perfusion due to a moderate increase in the aortic wall stiffness and CAS (increase of the aortic valve leaflets thickness). A marked drop of coronary peak velocity occurred when the values of leaflet thickness and aortic wall stiffness were above a certain threshold, corresponding to a threefold of their normal value. Consequently, mild and prophylactic treatments such as smoking cessation, exercise, or diet, which have been proven to increase the aortic compliance, may significantly improve the coronary perfusion.
Collapse
|