1
|
Zhang X, Beebe T, Jen N, Lee CA, Tai Y, Hsiai TK. Flexible and waterproof micro-sensors to uncover zebrafish circadian rhythms: The next generation of cardiac monitoring for drug screening. Biosens Bioelectron 2015; 71:150-157. [PMID: 25909335 DOI: 10.1016/j.bios.2015.04.027] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Revised: 03/30/2015] [Accepted: 04/12/2015] [Indexed: 01/01/2023]
Abstract
Flexible electronics are the next generation of sensors for mobile health and implantation. Zebrafish (Danio rerio) is an emergent strategy for pre-clinical drug development and toxicity testing. To address the confounding effects from sedation of fish and removal from the aquatic habitat for micro-electrocardiogram (µECG) measurements, we developed waterproof and wearable sensors to uncover the circadian variation in heart rate (HR) and heart rate variability (HRV) (Massin et al., 2000). The parylene-C based ECG sensor consisted of an ultra-soft silicone integrated jacket designed to wrap around the fish during swimming. The Young's modulus of this silicone jacket matched with the fish surface, and an extended parylene cable connected the underwater chest electrodes with the out-of water electronics. In addition, embedded micro-glass spheres in the silicone effectively reduced the effective density of the jacket to ~1 g cm(-3). These innovations enabled physiological ECG telemetry in the fish's natural habitat without the need for sedation. Furthermore, a set of non-linear signal processing techniques filtered out the breathing and electromagnetic artifacts from the recorded signals. We observed a reduction in mean HR and an increase in HRV over 24h at 10 dpa, accompanied by QT prolongation as well as diurnal variations, followed by normalization in mean HR and QT intervals at 26 days post ventricular amputation (dpa). We revealed Amiodarone-mediated QTc prolongation, HR reduction and HRV increase otherwise masked by sedation. The novel features of the flexible silicon jacket for µECG telemetry unraveled the biological clock and normalization of QT intervals at 26 dpa, providing the first evidence of new physiological phenomena during cardiac injury and repair as well as cardiac drug-mediated aberrant rhythms. Thus, the light weight and waterproof design holds promise to advance the next generation of mobile health and drug discovery.
Collapse
Affiliation(s)
- Xiaoxiao Zhang
- Department of Medical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Tyler Beebe
- Department of Bioengineering, UCLA School of Engineering & Applied Sciences, Los Angeles, CA 90095
| | - Nelon Jen
- Department of Bioengineering, UCLA School of Engineering & Applied Sciences, Los Angeles, CA 90095
| | - Chia-An Lee
- Division of Cardiology, Department of Medicine, UCLA School of Medicine, Los Angeles, CA 90095
| | - Yuchong Tai
- Department of Medical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Tzung K Hsiai
- Department of Bioengineering, UCLA School of Engineering & Applied Sciences, Los Angeles, CA 90095.,Division of Cardiology, Department of Medicine, UCLA School of Medicine, Los Angeles, CA 90095
| |
Collapse
|
2
|
Wu T, Wang J, Song Y, Deng X, Li A, Wei J, He L, Zhao X, Li R, Zhou Z, Wu W, Huang J, Jiao S, Yuan C, Chen H. Homologous HOmologous Black-Bright-blood and flexible Interleaved imaging sequence (HOBBI) for dynamic contrast-enhanced MRI of the vessel wall. Magn Reson Med 2014; 73:1754-63. [PMID: 24805922 DOI: 10.1002/mrm.25287] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Revised: 03/27/2014] [Accepted: 04/16/2014] [Indexed: 12/17/2022]
Abstract
PURPOSE To present a HOmologous Black-Bright-blood and flexible Interleaved imaging (HOBBI) sequence for dynamic contrast-enhanced magnetic resonance imaging (MRI) of the vessel wall. THEORY AND METHODS A HOBBI sequence is proposed to acquire high-spatial-resolution black-blood and high-temporal-resolution bright-blood dynamic contrast-enhanced images in an interleaved fashion. Black-blood imaging allows for thin vessel wall evaluation, whereas bright-blood imaging obtains the arterial input function accurately. A simulation was performed to assess the accuracy of the pharmacokinetic parameters [transfer constant (K(trans) ) and fractional plasma volume (vp )] generated from HOBBI. In vivo evaluation was also used to validate HOBBI in an animal model of aortic atherosclerosis. RESULTS In the simulation test, the estimated K(trans) and vp measured by HOBBI were more accurate than those from black-blood dynamic contrast-enhanced-MRI. In the animal model testing, K(trans) and vp also demonstrated good interscan reproducibility (K(trans) : ICC = 0.77, vp : ICC = 0.72, respectively). Additionally, K(trans) showed a significant increase from 1 month (0.026 ± 0.013 min(-1) ) to 2 months (0.069 ± 0.018 min(-1) ) in animal model plaque progression after balloon injury. CONCLUSION The proposed HOBBI sequence was demonstrated to be feasible and accurate in estimating the pharmacokinetic parameters of the atherosclerotic vessel wall, and has potential to become an early screening tool for atherosclerosis disease.
Collapse
Affiliation(s)
- Tingting Wu
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Jen N, Yu F, Lee J, Wasmund S, Dai X, Chen C, Chawareeyawong P, Yang Y, Li R, Hamdan MH, Hsiai TK. Atrial fibrillation pacing decreases intravascular shear stress in a New Zealand white rabbit model: implications in endothelial function. Biomech Model Mechanobiol 2013; 12:735-45. [PMID: 22983703 PMCID: PMC3548016 DOI: 10.1007/s10237-012-0437-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Accepted: 08/29/2012] [Indexed: 01/01/2023]
Abstract
Atrial fibrillation (AF) is characterized by multiple rapid and irregular atrial depolarization, leading to rapid ventricular responses exceeding 100 beats per minute (bpm). We hypothesized that rapid and irregular pacing reduced intravascular shear stress (ISS) with implication to modulating endothelial responses. To simulate AF, we paced the left atrial appendage of New Zealand White rabbits (n = 4) at rapid and irregular intervals. Surface electrical cardiograms were recorded for atrial and ventricular rhythm, and intravascular convective heat transfer was measured by microthermal sensors, from which ISS was inferred. Rapid and irregular pacing decreased arterial systolic and diastolic pressures (baseline, 99/75 mmHg; rapid regular pacing, 92/73; rapid irregular pacing, 90/68; p < 0.001, n = 4), temporal gradients ([Formula: see text] from 1,275 ± 80 to 1,056 ± 180 dyne/cm(2) s), and reduced ISS (from baseline at 32.0 ± 2.4 to 22.7 ± 3.5 dyne/cm(2)). Computational fluid dynamics code demonstrated that experimentally inferred ISS provided a close approximation to the computed wall shear stress at a given catheter to vessel diameter ratio, shear stress range, and catheter position. In an in vitro flow system in which time-averaged shear stress was maintained at [Formula: see text] , we further demonstrated that rapid pulse rates at 150 bpm down-regulated endothelial nitric oxide, promoted superoxide (O 2 (.-) ) production, and increased monocyte binding to endothelial cells. These findings suggest that rapid pacing reduces ISS and [Formula: see text] , and rapid pulse rates modulate endothelial responses.
Collapse
Affiliation(s)
- Nelson Jen
- Department of Biomedical Engineering and Cardiovascular Medicine, School of Engineering and Medicine, University of Southern California, Los Angeles, CA 90089, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Park HS, Kwon Y, Eom BW, Lee T. Prospective nonrandomized comparison of quality of life and recurrence between high ligation and stripping and radiofrequency ablation for varicose veins. JOURNAL OF THE KOREAN SURGICAL SOCIETY 2012; 84:48-56. [PMID: 23323236 PMCID: PMC3539110 DOI: 10.4174/jkss.2013.84.1.48] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 11/09/2012] [Accepted: 11/12/2012] [Indexed: 11/30/2022]
Abstract
Purpose Varicose veins are a major problem worldwide and improvement in quality of life (QoL) is the ultimate goal after treatment of this benign disease. However QoL is highly dependent on personal and social factors. This study compares high ligation and stripping (HS) and radiofrequency ablation (RFA) in terms of QoL and recurrence in Korea. Methods A retrospective analysis of prospectively collected data between August 2006 and October 2008 was performed for patients undergoing HS and RFA at a single institution. QoL was assessed with a questionnaire preoperatively, at 3 months postoperatively and annually thereafter. Recurrence was assessed by Duplex ultrasound annually after surgery. RESULTS A total of 272 patients completed the questionnaire at 3 months. Among these patients, 155 patients returned for their annual follow-up. There were no significant differences between HS and RFA in global QoL scores, although RFA showed less pain. However, paresthesia rates were also higher after RFA. Recurrence rates were similar between the two modalities, although technical failures were more common after RFA. Conclusion Overall QoL and recurrence rates were similar between the two modalities. The benefits of RFA do not seem to be enough to overcome the higher costs of HS in Korea.
Collapse
Affiliation(s)
- Hyung Sub Park
- Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | | | | | | |
Collapse
|
5
|
Yu F, Lee J, Jen N, Li X, Zhang Q, Tang R, Zhou Q, Kim ES, Hsiai TK. Elevated electrochemical impedance in the endoluminal regions with high shear stress: implication for assessing lipid-rich atherosclerotic lesions. Biosens Bioelectron 2012; 43:237-44. [PMID: 23318546 DOI: 10.1016/j.bios.2012.12.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 11/29/2012] [Accepted: 12/04/2012] [Indexed: 12/19/2022]
Abstract
BACKGROUND Identifying metabolically active atherosclerotic lesions remains an unmet clinical challenge during coronary intervention. Electrochemical impedance (EIS) increased in response to oxidized low density lipoprotein (oxLDL)-laden lesions. We hereby assessed whether integrating EIS with intravascular ultrasound (IVUS) and shear stress (ISS) provided a new strategy to assess oxLDL-laden lesions in the fat-fed New Zealand White (NZW) rabbits. METHODS AND RESULTS A micro-heat transfer sensor was deployed to acquire the ISS profiles at baseline and post high-fat diet (HD) in the NZW rabbits (n=8). After 9 weeks of HD, serum oxLDL levels (mg/dL) increased by 140 fold, accompanied by a 1.5-fold increase in kinematic viscosity (cP) in the HD group. Time-averaged ISS (ISSave) in the thoracic aorta also increased in the HD group (baseline: 17.61±0.24 vs. 9 weeks: 25.22±0.95dyne/cm(2), n=4), but remained unchanged in the normal diet group (baseline: 22.85±0.53dyn/cm(2) vs. 9 weeks: 22.37±0.57dyne/cm(2), n=4). High-frequency intravascular ultrasound (IVUS) revealed atherosclerotic lesions in the regions with augmented ISSave, and concentric bipolar microelectrodes demonstrated elevated EIS signals, which were correlated with prominent anti-oxLDL immuno-staining (oxLDL-free regions: 497±55Ω, n=8 vs. oxLDL-rich lesions: 679±125Ω, n=12, P<0.05). The equivalent circuit model for tissue resistance between the lesion-free and ox-LDL-rich lesions further validated the experimental EIS signals. CONCLUSIONS By applying electrochemical impedance in conjunction with shear stress and high-frequency ultrasound sensors, we provided a new strategy to identify oxLDL-laden lesions. The study demonstrated the feasibility of integrating EIS, ISS, and IVUS for a catheter-based approach to assess mechanically unstable plaque.
Collapse
Affiliation(s)
- Fei Yu
- Department of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Szeto CC, Kwan BCH, Chow KM, Leung CB, Law MC, Li PKT. Prognostic value of arterial pulse wave velocity in peritoneal dialysis patients. Am J Nephrol 2012; 35:127-33. [PMID: 22236995 DOI: 10.1159/000335580] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2011] [Accepted: 12/03/2011] [Indexed: 11/19/2022]
Abstract
BACKGROUND Cardiovascular disease is the most common cause of mortality in chronic peritoneal dialysis (PD) patients. Increased arterial stiffness may be related to a high peritoneal permeability, resulting in fluid overload of PD patients. We examined the prognostic value and factors that govern the longitudinal change of arterial pulse wave velocity (PWV) in Chinese PD patients. METHOD We enrolled 155 new PD patients. PWV was measured at baseline and then repeated after 2 years of follow-up. RESULTS At 24 months, the survival of patients with baseline carotid-femoral (CF)-PWV above 10 m/s was significantly worse than that of those with CF-PWV below 10 m/s (76.1 vs. 88.6%, p = 0.006). However, after adjusting for confounding factors, CF-PWV was not an independent predictor of survival. Amongst the 100 patients who had repeated PWV measurement after 2 years, the average CF-PWV increased from 9.92 ± 2.04 to 11.00 ± 2.30 m/s (p < 0.0001). The change in CF-PWV over 2 years significantly correlated with systolic blood pressure (r = 0.241, p = 0.036), serum calcium level (r = 0.231, p = 0.044), and normalized protein nitrogen appearance (NPNA) (r = -0.337, p = 0.001). CONCLUSIONS A high baseline CF-PWV was associated with a lower overall survival of Chinese PD patients, but the prognostic value of CF-PWV disappeared after adjusting for confounding factors. After 2 years of PD, most patients had progressive increase in CF-PWV; the magnitude of increase is related to systolic blood pressure, serum calcium level, and baseline NPNA. Further study is needed to determine whether serial measurement of CF-PWV provides additional prognostic information.
Collapse
Affiliation(s)
- Cheuk-Chun Szeto
- Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, SAR, China.
| | | | | | | | | | | |
Collapse
|
7
|
LI HAIRUI, KOCHHAR JASPREETSINGH, PAN JING, CHAN SUIYUNG, KANG LIFENG. NANO/MICROSCALE TECHNOLOGIES FOR DRUG DELIVERY. J MECH MED BIOL 2011. [DOI: 10.1142/s021951941100406x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Nano- and microscale technologies have made a marked impact on the development of drug delivery systems. The loading efficiency and particle size of nano/micro particles can be better controlled with these new technologies than conventional methods. Moreover, drug delivery systems are moving from simple particles to smart particles and devices with programmable functions. These technologies are also contributing to in vitro and in vivo drug testing, which are important to evaluate drug delivery systems. For in vitro tests, lab-on-a-chip models are potentially useful as alternatives to animal models. For in vivo test, nano/micro-biosensors are developed for testing chemicals and biologics with high sensitivity and selectivity. Here, we review the recent development of nanoscale and microscale technologies in drug delivery including drug delivery systems, in vitro and in vivo tests.
Collapse
Affiliation(s)
- HAIRUI LI
- Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - JASPREET SINGH KOCHHAR
- Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - JING PAN
- Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - SUI YUNG CHAN
- Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - LIFENG KANG
- Department of Pharmacy, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| |
Collapse
|
8
|
Yu F, Ai L, Dai W, Rozengurt N, Yu H, Hsiai TK. MEMS thermal sensors to detect changes in heat transfer in the pre-atherosclerotic regions of fat-fed New Zealand white rabbits. Ann Biomed Eng 2011; 39:1736-44. [PMID: 21380571 DOI: 10.1007/s10439-011-0283-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2011] [Accepted: 02/17/2011] [Indexed: 11/29/2022]
Abstract
Real-time detection of pre-atherosclerotic regions remains an unmet clinical challenge. We previously demonstrated the application of micro-electro-mechanical systems (MEMS) to detect changes in convective heat transfer in terms of sensor output voltages in the zone of flow reversal in an in vitro stenotic model. We hereby demonstrated changes in sensor output voltages in the pre-atherosclerotic regions in the New Zealand White rabbits fed on hypercholesterolemic diet (HD). After 8 weeks, we observed that mean output voltages (V(ave)) were similar in the distal aortic arch, thoracic, and abdominal aortas in the normal standard diet (ND) group, consistent with an absence of atherosclerosis. In HD group, V(ave) increased in the distal aortic arch (HD: V(ave) = 1.05 ± 0.04 V; ND: V(ave) = 0.12 ± 0.01 V, n = 3, p < 0.05) and in the thoracic aortas (HD: V(ave) = 0.72 ± 0.06 V; ND: V(ave) = 0.13 ± 0.024 V, n = 3, p < 0.05), consistent with the histological presence of pre-atherosclerosis. Despite HD diet, V (ave) magnitudes were similar to ND group in the abdominal aortas (HD: V(ave) = 0.14 ± 0.003 V; ND: V(ave) = 0.14 ± 0.004 V, n = 3), corroborating histological absence of pre-atherosclerosis. Hence, MEMS thermal sensors provide a new approach to detect changes in convective heat transfer in the pre-atherosclerotic regions.
Collapse
Affiliation(s)
- Fei Yu
- Department of Biomedical Engineering and Division of Cardiovascular Medicine, School of Engineering & School of Medicine, University of Southern California, Los Angeles, CA 90089-1111, USA
| | | | | | | | | | | |
Collapse
|
9
|
Ai L, Zhang L, Dai W, Hu C, Shung KK, Hsiai TK. Real-time assessment of flow reversal in an eccentric arterial stenotic model. J Biomech 2010; 43:2678-83. [PMID: 20655537 DOI: 10.1016/j.jbiomech.2010.06.021] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2010] [Revised: 06/18/2010] [Accepted: 06/20/2010] [Indexed: 11/17/2022]
Abstract
Plaque rupture is the leading cause of acute coronary syndromes and stroke. Plaque formation, otherwise known as stenosis, preferentially occurs in the regions of arterial bifurcation or curvatures. To date, real-time assessment of stenosis-induced flow reversal remains a clinical challenge. By interfacing microelectromechanical system (MEMS) thermal sensors with the high frequency pulsed wave (PW) Doppler ultrasound, we proposed to assess flow reversal in the presence of an eccentric stenosis. We developed a 3-D stenotic model (inner diameter of 6mm, an eccentric stenosis with a height of 2.75 mm, and width of 21 mm) simulating a superficial arterial vessel. We demonstrated that heat transfer from the sensing element (2 x 80 μm²) to the flow field peaked as a function of flow rates at the throat of the stenosis along the center/midline of arterial model, and dropped downstream from the stenosis, where flow reversal was detected by the high frequency ultrasound device at 45 MHz. Computational fluid dynamics (CFD) codes are in agreement with the ultrasound-acquired flow profiles upstream, downstream, and at the throat of the stenosis. Hence, we characterized regions of eccentric stenosis in terms of changes in heat transfer along the midline of vessel and identified points of flow reversal with high spatial and temporal resolution.
Collapse
Affiliation(s)
- Lisong Ai
- Department of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, USA.
| | | | | | | | | | | |
Collapse
|