Lindenhahn P, Richter J, Pepelanova I, Seeger B, Volk HA, Hinkel R, Hiebl B, Scheper T, Hinrichs JB, Becker LS, Haverich A, Kaufeld T. A Novel Artificial Coronary Plaque to Model Coronary Heart Disease. Biomimetics (Basel) 2024; 9:197. [PMID: 38667208 PMCID: PMC11048636 DOI: 10.3390/biomimetics9040197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 03/16/2024] [Accepted: 03/20/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Experimental coronary artery interventions are currently being performed on non-diseased blood vessels in healthy animals. To provide a more realistic pathoanatomical scenario for investigations on novel interventional and surgical therapies, we aimed to fabricate a stenotic lesion, mimicking the morphology and structure of a human atherosclerotic plaque. METHODS In an interdisciplinary setting, we engineered a casting mold to create an atherosclerotic plaque with the dimensions to fit in a porcine coronary artery. Oscillatory rheology experiments took place along with long-term stability tests assessed by microscopic examination and weight monitoring. For the implantability in future in vivo setups, we performed a cytotoxicity assessment, inserted the plaque in resected pig hearts, and performed diagnostic imaging to visualize the plaque in its final position. RESULTS The most promising composition consists of gelatin, cholesterol, phospholipids, hydroxyapatite, and fine-grained calcium carbonate. It can be inserted in the coronary artery of human-sized pig hearts, producing a local partial stenosis and interacting like the atherosclerotic plaque by stretching and shrinking with the vessel wall and surrounding tissue. CONCLUSION This artificial atherosclerotic plaque model works as a simulating tool for future medical testing and could be crucial for further specified research on coronary artery disease and is going to help to provide information about the optimal interventional and surgical care of the disease.
Collapse
Affiliation(s)
- Philipp Lindenhahn
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30559 Hannover, Germany; (A.H.); (T.K.)
- Department of Small Animal Medicine and Surgery, University of Veterinary Medicine Hanover, 30559 Hannover, Germany
| | - Jannik Richter
- Institute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany; (J.R.); (T.S.)
| | - Iliyana Pepelanova
- Institute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany; (J.R.); (T.S.)
| | - Bettina Seeger
- Institute for Food Quality and Food Safety, University of Veterinary Medicine, 30559 Hannover, Germany;
| | - Holger A. Volk
- Department of Small Animal Medicine and Surgery, University of Veterinary Medicine Hanover, 30559 Hannover, Germany
| | - Rabea Hinkel
- Department of Laboratory Animal Science, Leibnitz-Institut für Primatenforschung, Deutsches Primatenzentrum GmbH, Kellnerweg 4, 37077 Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Göttingen, 37075 Göttingen, Germany
- Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine, 30559 Hannover, Germany;
| | - Bernhard Hiebl
- Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine, 30559 Hannover, Germany;
| | - Thomas Scheper
- Institute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany; (J.R.); (T.S.)
| | - Jan B. Hinrichs
- Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany; (J.B.H.); (L.S.B.)
| | - Lena S. Becker
- Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany; (J.B.H.); (L.S.B.)
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30559 Hannover, Germany; (A.H.); (T.K.)
| | - Tim Kaufeld
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30559 Hannover, Germany; (A.H.); (T.K.)
| |
Collapse
|
2
|
Sakaeyama Y, Kondo K, Terazono S, Fuchinoue Y, Kubota S, Mikai M, Abe M, Sugo N, Nagao T, Nemoto M. Local and systemic factors associated with quantitative stiffness of carotid plaque. Acta Neurochir (Wien) 2024; 166:54. [PMID: 38289409 DOI: 10.1007/s00701-024-05952-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 01/06/2024] [Indexed: 02/01/2024]
Abstract
PURPOSE Plaque stiffness in carotid artery stenosis is a clinically important factor involved in the development of stroke and surgical complications. The purpose of this study was to clarify which local and systemic factors are associated with the quantitatively measured stiffness of plaque. METHODS The subjects were 104 consecutive patients who underwent carotid endarterectomy at our institution. To measure quantitative stiffness of plaque, we used an industrial hard meter in the operating room within 1 h after removal of plaque. Local factors related to carotid plaque hardness were evaluated, including maximum intima-media thickness (max IMT), degree of stenosis using the European Carotid Surgery Trial (ECST), presence of ulceration or calcification, and echo brightness on preoperative carotid ultrasound. The degree of stenosis was also evaluated using the North American Symptomatic Carotid Endarterectomy Trial method in digital subtraction angiography. Age, sex, and presence or absence of hypertension, diabetes, and dyslipidemia (low-density lipoprotein cholesterol and triglyceride [TG] levels) served as systemic factors and were compared with the quantitative stiffness of carotid plaque. RESULTS In multivariate analysis, ECST stenosis degree, calcification, and IMT max as local factors affected plaque stiffness. As a systemic factor, plaque stiffness was statistically significantly negatively correlated with TG values in multivariate analysis (p < 0.05). CONCLUSION The quantitative stiffness of the plaque was negatively correlated with TG levels as a systemic factor in addition to local factors. This might suggest that reducing high TG levels is associated with plaque stabilization.
Collapse
Affiliation(s)
- Yuki Sakaeyama
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | - Kosuke Kondo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | - Sayaka Terazono
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | - Yutaka Fuchinoue
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | | | - Masataka Mikai
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | | | - Nobuo Sugo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1, Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan.
| | - Takaaki Nagao
- Department of Neurosurgery (Sakura), School of Medicine, Faculty of Medicine, Toho University, Sakura-City, Chiba, Japan
| | - Masaaki Nemoto
- Department of Neurosurgery (Sakura), School of Medicine, Faculty of Medicine, Toho University, Sakura-City, Chiba, Japan
| |
Collapse
|
3
|
Tornifoglio B, Johnston RD, Stone AJ, Kerskens C, Lally C. Microstructural and mechanical insight into atherosclerotic plaques: an ex vivo DTI study to better assess plaque vulnerability. Biomech Model Mechanobiol 2023; 22:1515-1530. [PMID: 36652053 PMCID: PMC10511397 DOI: 10.1007/s10237-022-01671-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 12/08/2022] [Indexed: 01/19/2023]
Abstract
Non-invasive microstructural characterisation has the potential to determine the stability, or lack thereof, of atherosclerotic plaques and ultimately aid in better assessing plaques' risk to rupture. If linked with mechanical characterisation using a clinically relevant imaging technique, mechanically sensitive rupture risk indicators could be possible. This study aims to provide this link-between a clinically relevant imaging technique and mechanical characterisation within human atherosclerotic plaques. Ex vivo diffusion tensor imaging, mechanical testing, and histological analysis were carried out on human carotid atherosclerotic plaques. DTI-derived tractography was found to yield significant mechanical insight into the mechanical properties of more stable and more vulnerable microstructures. Coupled with insights from digital image correlation and histology, specific failure characteristics of different microstructural arrangements furthered this finding. More circumferentially uniform microstructures failed at higher stresses and strains when compared to samples which had multiple microstructures, like those seen in a plaque cap. The novel findings in this study motivate diagnostic measures which use non-invasive characterisation of the underlying microstructure of plaques to determine their vulnerability to rupture.
Collapse
Affiliation(s)
- B Tornifoglio
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - R D Johnston
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - A J Stone
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Medical Physics and Clinical Engineering, St. Vincent's University Hospital, Dublin, Ireland
| | - C Kerskens
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Trinity College Institute of Neuroscience, Trinity College Dublin, Dublin, Ireland
| | - C Lally
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland.
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland.
- Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland.
| |
Collapse
|
4
|
Torun SG, Munoz PDM, Crielaard H, Verhagen HJM, Kremers GJ, van der Steen AFW, Akyildiz AC. Local Characterization of Collagen Architecture and Mechanical Failure Properties of Fibrous Plaque Tissue of Atherosclerotic Human Carotid Arteries. Acta Biomater 2023; 164:293-302. [PMID: 37086826 DOI: 10.1016/j.actbio.2023.04.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 04/05/2023] [Accepted: 04/13/2023] [Indexed: 04/24/2023]
Abstract
Atherosclerotic plaque rupture in carotid arteries is a major cause of cerebrovascular events. Plaque rupture is the mechanical failure of the heterogeneous fibrous plaque tissue. Local characterization of the tissue's failure properties and the collagen architecture are of great importance to have insights in plaque rupture for clinical event prevention. Previous studies were limited to average rupture properties and global structural characterization, and did not provide the necessary local information. In this study, we assessed the local collagen architecture and failure properties of fibrous plaque tissue, by analyzing 30 tissue strips from 18 carotid plaques. Our study framework entailed second harmonic generation imaging for local collagen orientation and dispersion, and uniaxial tensile testing and digital image correlation for local tissue mechanics. The results showed that 87% of the imaged locations had collagen orientation close to the circumferential direction (0°) of the artery, and substantial dispersion locally. All regions combined, median [Q1:Q3] of the predominant angle measurements was -2° [-16°:16°]. The stretch ratio measurements clearly demonstrated a nonuniform stretch ratio distribution in the tissue under uniaxial loading. The rupture initiation regions had significantly higher stretch ratios (1.26 [1.15-1.40]) than the tissue average stretch ratio (1.11 [1.10-1.16]). No significant difference in collagen direction and dispersion was identified between the rupture regions and the rest of the tissue. The presented study forms an initial step towards gaining better insights into the characterization of local structural and mechanical fingerprints of fibrous plaque tissue in order to aid improved assessment of plaque rupture risk. STATEMENT OF SIGNIFICANCE: Plaque rupture risk assessment, critical to prevent cardiovascular events, requires knowledge on local failure properties and structure of collagenous plaque tissue. Our current knowledge is unfortunately limited to tissue's overall ultimate failure properties with scarce information on collagen architecture. In this study, local failure properties and collagen architecture of fibrous plaque tissue were obtained. We found predominant circumferential alignment of collagen fibers with substantial local dispersion. The tissue showed nonuniform stretch distribution under uniaxial tensile loading, with high stretches at rupture spots. This study highlights the significance of local mechanical and structural assessment for better insights into plaque rupture and the potential use of local stretches as risk marker for plaque rupture for patient-specific clinical applications.
Collapse
Affiliation(s)
- Su Guvenir Torun
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Pablo de Miguel Munoz
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Hanneke Crielaard
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Hence J M Verhagen
- Department of Vascular Surgery, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Gert-Jan Kremers
- Erasmus Optical Imaging Center, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Antonius F W van der Steen
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Ali C Akyildiz
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
| |
Collapse
|
5
|
Methodology for estimation of undeformed thickness of arterial tissues. Sci Rep 2023; 13:2816. [PMID: 36797267 PMCID: PMC9935509 DOI: 10.1038/s41598-023-28871-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 01/25/2023] [Indexed: 02/18/2023] Open
Abstract
Soft tissue sample thickness measurement is one of the major sources of differences between mechanical responses published by different groups. New method for the estimation of unloaded sample thickness of soft tissues is proposed in this study. Ten 30 × 30 mm and ten 20 × 20 mm samples of porcine anterior thoracic aortas were loaded by gradually increased radial force. Their deformed thickness was then recorded in order to generate a pressure-thickness response. Next, the limit pressure to which the response can be considered linear was estimated. Line was fitted to the linear part of the curve and extrapolated towards zero pressure to estimate unloaded thickness (7 kPa fit). For comparison, data near zero pressure were fitted separately and extrapolated towards zero (Near Zero fit). The limit pressure for the linearity of the response was around 7 kPa. The Unloaded thickness for 30 × 30 mm samples was 2.68 ± 0.31 mm and 2.68 ± 0.3 mm for Near Zero fit and 7 kPa fit, respectively. The Unloaded thickness for 20 × 20 mm samples was 2.60 ± 0.35 mm and 2.59 ± 0.35 mm for Near Zero fit and 7 kPa fit, respectively. The median of thickness difference between smaller and larger samples was not found statistically different. Proposed method can estimate unloaded undeformed sample thickness quickly and reliably.
Collapse
|
6
|
Understanding Atherosclerosis Pathophysiology: Can Additive Manufacturing Be Helpful? Polymers (Basel) 2023; 15:polym15030480. [PMID: 36771780 PMCID: PMC9920326 DOI: 10.3390/polym15030480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/12/2023] [Accepted: 01/14/2023] [Indexed: 01/18/2023] Open
Abstract
Atherosclerosis is one of the leading causes of death worldwide. Although this subject arouses much interest, there are limitations associated with the biomechanical investigation done in atherosclerotic tissues, namely the unstandardized tests for the mechanical characterization of these tissues and the inherent non-consensual results obtained. The variability of tests and typologies of samples hampers direct comparisons between results and hinders the complete understanding of the pathologic process involved in atherosclerosis development and progression. Therefore, a consensual and definitive evaluation of the mechanical properties of healthy and atherosclerotic blood vessels would allow the production of physical biomodels that could be used for surgeons' training and personalized surgical planning. Additive manufacturing (AM), commonly known as 3D printing, has attracted significant attention due to the potential to fabricate biomodels rapidly. However, the existing literature regarding 3D-printed atherosclerotic vascular models is still very limited. Consequently, this review intends to present the atherosclerosis disease and the consequences of this pathology, discuss the mechanical characterization of atherosclerotic vessels/plaques, and introduce AM as a potential strategy to increase the understanding of atherosclerosis treatment and pathophysiology.
Collapse
|
7
|
Caballero R, Martínez MÁ, Peña E. Coronary artery properties in atherosclerosis: A deep learning predictive model. Front Physiol 2023; 14:1162436. [PMID: 37089419 PMCID: PMC10113490 DOI: 10.3389/fphys.2023.1162436] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 03/21/2023] [Indexed: 04/25/2023] Open
Abstract
In this work an Artificial Neural Network (ANN) was developed to help in the diagnosis of plaque vulnerability by predicting the Young modulus of the core (E core ) and the plaque (E plaque ) of atherosclerotic coronary arteries. A representative in silico database was constructed to train the ANN using Finite Element simulations covering the ranges of mechanical properties present in the bibliography. A statistical analysis to pre-process the data and determine the most influential variables was performed to select the inputs of the ANN. The ANN was based on Multilayer Perceptron architecture and trained using the developed database, resulting in a Mean Squared Error (MSE) in the loss function under 10-7, enabling accurate predictions on the test dataset for E core and E plaque . Finally, the ANN was applied to estimate the mechanical properties of 10,000 realistic plaques, resulting in relative errors lower than 3%.
Collapse
Affiliation(s)
- Ricardo Caballero
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | - Miguel Ángel Martínez
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicina (CIBER-BBN), Madrid, Spain
| | - Estefanía Peña
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicina (CIBER-BBN), Madrid, Spain
- *Correspondence: Estefanía Peña,
| |
Collapse
|
8
|
Abstract
PURPOSE OF REVIEW Aging is an important risk factor for cardiovascular disease and is associated with increased vessel wall stiffness. Pathophysiological stiffening, notably in arteries, disturbs the integrity of the vascular endothelium and promotes permeability and transmigration of immune cells, thereby driving the development of atherosclerosis and related vascular diseases. Effective therapeutic strategies for arterial stiffening are still lacking. RECENT FINDINGS Here, we overview the literature on age-related arterial stiffening, from patient-derived data to preclinical in-vivo and in-vitro findings. First, we overview the common techniques that are used to measure stiffness and discuss the observed stiffness values in atherosclerosis and aging. Next, the endothelial response to stiffening and possibilities to attenuate this response are discussed. SUMMARY Future research that will define the endothelial contribution to stiffness-related cardiovascular disease may provide new targets for intervention to restore endothelial function in atherosclerosis and complement the use of currently applied lipid-lowering, antihypertensive, and anti-inflammatory drugs.
Collapse
Affiliation(s)
- Aukie Hooglugt
- Amsterdam UMC, University of Amsterdam, Department of Medical Biochemistry, Amsterdam Cardiovascular Sciences
- Amsterdam UMC, VU University Medical Center, Department of Physiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Olivia Klatt
- Amsterdam UMC, University of Amsterdam, Department of Medical Biochemistry, Amsterdam Cardiovascular Sciences
| | - Stephan Huveneers
- Amsterdam UMC, University of Amsterdam, Department of Medical Biochemistry, Amsterdam Cardiovascular Sciences
| |
Collapse
|
9
|
Corti A, Shameen T, Sharma S, De Paolis A, Cardoso L. Tunable elastomer materials with vascular tissue-like rupture mechanics behavior. Biomed Phys Eng Express 2022; 8. [PMID: 35863160 DOI: 10.1088/2057-1976/ac82f6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 07/21/2022] [Indexed: 11/11/2022]
Abstract
Purpose:Laboratory models of human arterial tissues are advantageous to examine the mechanical response of blood vessels in a simplified and controllable manner. In the present study, we investigated three silicone-based materials for replicating the mechanical properties of human arteries documented in the literature.Methods:We performed uniaxial tensile tests up to rupture on Sylgard184, Sylgard170 and DowsilEE-3200 under different curing conditions and obtained their True (Cauchy) stress-strain behavior and Poisson's ratios by means of digital image correlation (DIC). For each formulation, we derived the constitutive parameters of the 3-term Ogden model and designed numerical simulations of tubular models under a radial pressure of 250mmHg.Results:Each material exhibits evident non-linear hyperelasticity and dependence on the curing condition. Sylgard184 is the stiffest formulation, with the highest shear moduli and ultimate stresses at relative low strains (µ184=0.52-0.88MPa, σ184=15.90-16.54MPa, ε184=0.72-0.96). Conversely, Sylgard170 and DowsilEE-3200 present significantly lower shear moduli and ultimate stresses that are closer to data reported for arterial tissues (µ170=0.33-0.7MPa σ170=2.61-3.67MPa, ε170=0.69-0.81; µdow=0.02-0.09MPa σdow=0.83-2.05MPa, εdow=0.91-1.05). Under radial pressure, all formulations except DowsilEE-3200 at 1:1 curing ratio undergo circumferential stresses that remain in the elastic region with values ranging from 0.1 to 0.18MPa. Conclusion: Sylgard170 and DowsilEE-3200 appear to better reproduce the rupture behavior of vascular tissues within their typical ultimate stress and strain range. Numerical models demonstrate that all three materials achieve circumferential stresses similar to human common carotid arteries (Sommer et al. 2010), making these formulations suited for cylindrical laboratory models under physiological and supraphysiological loading.
Collapse
Affiliation(s)
- Andrea Corti
- The City College of New York, 275 Convent Ave, New York, New York, 10031-9101, UNITED STATES
| | - Tariq Shameen
- The City College of New York, 275 Convent Ave, New York, New York, 10031-9101, UNITED STATES
| | - Shivang Sharma
- The City College of New York, 275 Convent Ave, New York, New York, 10031-9101, UNITED STATES
| | - Annalisa De Paolis
- The City College of New York, 275 Convent Ave, New York, New York, 10031-9101, UNITED STATES
| | - Luis Cardoso
- Biomedical Engineering, The City College of New York, 275 Convent Ave, New York, New York, New York, 10031-9101, UNITED STATES
| |
Collapse
|
10
|
Fukushima D, Kondo K, Harada N, Terazono S, Uchino K, Shibuya K, Sugo N. Quantitative comparison between carotid plaque hardness and histopathological findings: an observational study. Diagn Pathol 2022; 17:58. [PMID: 35818059 PMCID: PMC9275256 DOI: 10.1186/s13000-022-01239-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 06/12/2022] [Indexed: 12/02/2022] Open
Abstract
Background Plaque hardness in carotid artery stenosis correlates with cerebral infarction. This study aimed to quantitatively compare plaque hardness with histopathological findings and identify the pathological factors involved in plaque hardness. Methods This study included 84 patients (89 lesions) undergoing carotid endarterectomy (CEA) at our institution. Plaque hardness was quantitatively measured immediately after excision using a hardness meter. Collagen and calcification were evaluated as the pathological factors. Collagen was stained with Elastica van Gieson stain, converted to a gray-scale image, and displayed in a 256-step histogram. The median gray-scale median (GSM) was used as the collagen content. The degree of calcification was defined by the hematoxylin–eosin stain as follows: "0:" no calcification, "1:" scattered microcalcification, or "2:" calcification greater than 1 mm or more than 2% of the total calcification. Carotid echocardiographic findings, specifically echoluminance or the brightness of the narrowest lesion of the plaque, classified as hypo-, iso-, or hyper-echoic by comparison with the intima-media complex surrounding the plaque, and clinical data were reviewed. Results Plaque hardness was significantly negatively correlated with GSM [Spearman's correlation coefficient: -0.7137 (p < 0.0001)]: the harder the plaque, the higher the collagen content. There were significant differences between plaque hardness and degree of calcification between "0" and "2" (p = 0.0206). For plaque hardness and echoluminance (hypo-iso-hyper), significant differences were found between hypo-iso (p = 0.0220), hypo-hyper (p = 0.0006), and iso-hyper (p = 0.0015): the harder the plaque, the higher the luminance. In single regression analysis, GSM, sex, and diabetes mellitus were significant variables, and in multiple regression analysis, only GSM was extracted as a significant variable. Conclusions Plaque hardness was associated with a higher amount of collagen, which is the main component of the fibrous cap. Greater plaque hardness was associated with increased plaque stability. The degree of calcification may also be associated with plaque hardness.
Collapse
Affiliation(s)
- Daisuke Fukushima
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan.
| | - Kosuke Kondo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan
| | - Naoyuki Harada
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan
| | - Sayaka Terazono
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan
| | - Kei Uchino
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan
| | - Kazutoshi Shibuya
- Department of Pathology, Toho University Omori Medical Center, Tokyo, Japan
| | - Nobuo Sugo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Tokyo, 143-8541, Japan
| |
Collapse
|
11
|
The viscoelastic characteristics of in-vitro carotid plaque by Kelvin-Voigt fractional derivative modeling. J Biomech 2022; 141:111210. [DOI: 10.1016/j.jbiomech.2022.111210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 06/10/2022] [Accepted: 06/23/2022] [Indexed: 11/20/2022]
|
12
|
Towards a Digital Twin of Coronary Stenting: A Suitable and Validated Image-Based Approach for Mimicking Patient-Specific Coronary Arteries. ELECTRONICS 2022. [DOI: 10.3390/electronics11030502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Considering the field of application involving stent deployment simulations, the exploitation of a digital twin of coronary stenting that can reliably mimic the patient-specific clinical reality could lead to improvements in individual treatments. A starting step to pursue this goal is the development of simple, but at the same time, robust and effective computational methods to obtain a good compromise between the accuracy of the description of physical phenomena and computational costs. Specifically, this work proposes an approach for the development of a patient-specific artery model to be used in stenting simulations. The finite element model was generated through a 3D reconstruction based on the clinical imaging (coronary Optical Coherence Tomography (OCT) and angiography) acquired on the pre-treatment patient. From a mechanical point of view, the coronary wall was described with a suitable phenomenological model, which is consistent with more complex constitutive approaches and accounts for the in vivo pressurization and axial pre-stretch. The effectiveness of this artery modeling method was tested by reproducing in silico the stenting procedures of two clinical cases and comparing the computational results with the in vivo lumen area of the stented vessel.
Collapse
|
13
|
Lisický O, Hrubanová A, Staffa R, Vlachovský R, Burša J. Constitutive models and failure properties of fibrous tissues of carotid artery atheroma based on their uniaxial testing. J Biomech 2021; 129:110861. [PMID: 34775341 DOI: 10.1016/j.jbiomech.2021.110861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/07/2021] [Accepted: 11/01/2021] [Indexed: 11/17/2022]
Abstract
To obtain an experimental background for the description of mechanical properties of fibrous tissues of carotid atheroma, a cohort of 141 specimens harvested from 44 patients during endarterectomies, were tested. Uniaxial stress-strain curves and ultimate stress and strain at rupture were recorded. With this cohort, the impact of the direction of load, presence of calcifications, specimen location, patient's age and sex were investigated. A significant impact of sex was revealed for the stress-strain curves and ultimate strains. The response was significantly stiffer for females than for males but, in contrast to ultimate strain, the strength was not significantly different. The differences in strength between calcified and non-calcified atheromas have reached statistical significance in the female group. At most of the analysed stress levels, the loading direction was found significant for the male cohort which was also confirmed by large differences in ultimate strains. The representative uniaxial stress-strain curves (given by median values of strains at chosen stress levels) were fitted with an isotropic hyperelastic model for different groups specified by the investigated factors while the observed differences between circumferential and longitudinal direction were captured by an anisotropic hyperelastic model. The obtained results should be valid also for the tissue of the fibrous cap, the rupture of which is to be predicted in clinics using computational modelling because it may induce arterial thrombosis and consequently a brain stroke.
Collapse
Affiliation(s)
- Ondřej Lisický
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic.
| | - Anna Hrubanová
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic
| | - Robert Staffa
- 2(nd) Department of Surgery, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Robert Vlachovský
- 2(nd) Department of Surgery, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jiří Burša
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic
| |
Collapse
|
14
|
Guvenir Torun S, Torun HM, Hansen HHG, de Korte CL, van der Steen AFW, Gijsen FJH, Akyildiz AC. Multicomponent material property characterization of atherosclerotic human carotid arteries through a Bayesian Optimization based inverse finite element approach. J Mech Behav Biomed Mater 2021; 126:104996. [PMID: 34864574 DOI: 10.1016/j.jmbbm.2021.104996] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 11/01/2021] [Accepted: 11/23/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Plaque rupture in atherosclerotic carotid arteries is a main cause of ischemic stroke and it is correlated with high plaque stresses. Hence, analyzing stress patterns is essential for plaque specific rupture risk assessment. However, the critical information of the multicomponent material properties of atherosclerotic carotid arteries is still lacking greatly. This work aims to characterize component-wise material properties of atherosclerotic human carotid arteries under (almost) physiological loading conditions. METHODS An inverse finite element modeling (iFEM) framework was developed to characterize fibrous intima and vessel wall material properties of 13 cross sections from five carotids. The novel pipeline comprised ex-vivo inflation testing, pre-clinical high frequency ultrasound for deriving plaque deformations, pre-clinical high-magnetic field magnetic resonance imaging, finite element modeling, and a sample efficient machine learning based Bayesian Optimization. RESULTS The nonlinear Yeoh constants for the fibrous intima and wall layers were successfully obtained. The optimization scheme of the iFEM reached the global minimum with a mean error of 3.8% in 133 iterations on average. The uniqueness of the results were confirmed with the inverted Gaussian Process (GP) model trained during the iFEM protocol. CONCLUSION The developed iFEM approach combined with the inverted GP model successfully predicted component-wise material properties of intact atherosclerotic human carotids ex-vivo under physiological-like loading conditions. SIGNIFICANCE We developed a novel iFEM framework for the nonlinear, component-wise material characterization of atherosclerotic arteries and utilized it to obtain human atherosclerotic carotid material properties. The developed iFEM framework has great potential to be advanced for patient-specific in-vivo application.
Collapse
Affiliation(s)
- Su Guvenir Torun
- Department of Biomedical Engineering, Erasmus Medical Center, 3015 GD, Rotterdam, the Netherlands.
| | - Hakki M Torun
- School of Electrical and Computer Engineering, Georgia Institute Technology, Atlanta, GA, USA
| | - Hendrik H G Hansen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Chris L de Korte
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | | | - Frank J H Gijsen
- Department of Biomedical Engineering, Erasmus Medical Center, 3015 GD, Rotterdam, the Netherlands; Department of Biomechanical Engineering, Delft University of Technology, the Netherlands
| | - Ali C Akyildiz
- Department of Biomedical Engineering, Erasmus Medical Center, 3015 GD, Rotterdam, the Netherlands; Department of Biomechanical Engineering, Delft University of Technology, the Netherlands
| |
Collapse
|
15
|
Wang L, Zhu J, Maehara A, Lv R, Qu Y, Zhang X, Guo X, Billiar KL, Chen L, Ma G, Mintz GS, Tang D. Quantifying Patient-Specific in vivo Coronary Plaque Material Properties for Accurate Stress/Strain Calculations: An IVUS-Based Multi-Patient Study. Front Physiol 2021; 12:721195. [PMID: 34759832 PMCID: PMC8575450 DOI: 10.3389/fphys.2021.721195] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 09/23/2021] [Indexed: 11/15/2022] Open
Abstract
Introduction: Mechanical forces are closely associated with plaque progression and rupture. Precise quantifications of biomechanical conditions using in vivo image-based computational models depend heavily on the accurate estimation of patient-specific plaque mechanical properties. Currently, mechanical experiments are commonly performed on ex vivo cardiovascular tissues to determine plaque material properties. Patient-specific in vivo coronary material properties are scarce in the existing literature. Methods:In vivo Cine intravascular ultrasound and virtual histology intravascular ultrasound (IVUS) slices were acquired at 20 plaque sites from 13 patients. A three-dimensional thin-slice structure-only model was constructed for each slice to obtain patient-specific in vivo material parameter values following an iterative scheme. Effective Young's modulus (YM) was calculated to indicate plaque stiffness for easy comparison purposes. IVUS-based 3D thin-slice models using in vivo and ex vivo material properties were constructed to investigate their impacts on plaque wall stress/strain (PWS/PWSn) calculations. Results: The average YM values in the axial and circumferential directions for the 20 plaque slices were 599.5 and 1,042.8 kPa, respectively, 36.1% lower than those from published ex vivo data. The YM values in the circumferential direction of the softest and stiffest plaques were 103.4 and 2,317.3 kPa, respectively. The relative difference of mean PWSn on lumen using the in vivo and ex vivo material properties could be as high as 431%, while the relative difference of mean PWS was much lower, about 3.07% on average. Conclusion: There is a large inter-patient and intra-patient variability in the in vivo plaque material properties. In vivo material properties have a great impact on plaque stress/strain calculations. In vivo plaque material properties have a greater impact on strain calculations. Large-scale-patient studies are needed to further verify our findings.
Collapse
Affiliation(s)
- Liang Wang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Jian Zhu
- Department of Cardiology, Zhongda Hospital, Southeast University, Nanjing, China
| | - Akiko Maehara
- The Cardiovascular Research Foundation, Columbia University, New York, NY, United States
| | - Rui Lv
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Yangyang Qu
- Department of Cardiology, Zhongda Hospital, Southeast University, Nanjing, China
| | - Xiaoguo Zhang
- Department of Cardiology, Zhongda Hospital, Southeast University, Nanjing, China
| | - Xiaoya Guo
- School of Science, Nanjing University of Posts and Telecommunications, Nanjing, China
| | - Kristen L Billiar
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
| | - Lijuan Chen
- Department of Cardiology, Zhongda Hospital, Southeast University, Nanjing, China
| | - Genshan Ma
- Department of Cardiology, Zhongda Hospital, Southeast University, Nanjing, China
| | - Gary S Mintz
- The Cardiovascular Research Foundation, Columbia University, New York, NY, United States
| | - Dalin Tang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, China.,Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA, United States
| |
Collapse
|
16
|
Lisický O, Hrubanová A, Burša J. Interpretation of Experimental Data is Substantial for Constitutive Characterization of Arterial Tissue. J Biomech Eng 2021; 143:104501. [PMID: 33973008 DOI: 10.1115/1.4051120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Indexed: 11/08/2022]
Abstract
The paper aims at evaluation of mechanical tests of soft tissues and creation of their representative stress-strain responses and respective constitutive models. Interpretation of sets of experimental results depends highly on the approach to the data analysis. Their common representation through mean and standard deviation may be misleading and give nonrealistic results. In the paper, raw data of seven studies consisting of 11 experimental data sets (concerning carotid wall and atheroma tissues) are re-analyzed to show the importance of their rigorous analysis. The sets of individual uniaxial stress-stretch curves are evaluated using three different protocols: stress-based, stretch-based, and constant-based, and the population-representative response is created by their mean or median values. Except for nearly linear responses, there are substantial differences between the resulting curves, being mostly the highest for constant-based evaluation. But also the stretch-based evaluation may change the character of the response significantly. Finally, medians of the stress-based responses are recommended as the most rigorous approach for arterial and other soft tissues with significant strain stiffening.
Collapse
Affiliation(s)
- Ondřej Lisický
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno 601 90, Czech Republic
| | - Anna Hrubanová
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno 601 90, Czech Republic
| | - Jiří Burša
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno 601 90, Czech Republic
| |
Collapse
|
17
|
Bennati L, Vergara C, Domanin M, Malloggi C, Bissacco D, Trimarchi S, Silani V, Parati G, Casana R. A Computational Fluid-Structure Interaction Study for Carotids With Different Atherosclerotic Plaques. J Biomech Eng 2021; 143:091002. [PMID: 33876184 DOI: 10.1115/1.4050910] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Indexed: 11/08/2022]
Abstract
Atherosclerosis is a systemic disease that leads to accumulation of deposits, known as atherosclerotic plaques, within the walls of the carotids. In particular, three types of plaque can be distinguished: soft, fibrous, and calcific. Most of the computational studies who investigated the interplay between the plaque and the blood flow on patient-specific geometries used nonstandard medical images to directly delineate and segment the plaque and its components. However, these techniques are not so widely available in the clinical practice. In this context, the aim of our work was twofold: (i) to propose a new geometric tool that allowed to reconstruct a plausible plaque in the carotids from standard images and (ii) to perform three-dimensional (3D) fluid-structure interaction (FSI) simulations where we compared some fluid-dynamic and structural quantities among 15 patients characterized by different typologies of plaque. Our results highlighted that both the morphology and the mechanical properties of different plaque components play a crucial role in determining the vulnerability of the plaque.
Collapse
Affiliation(s)
- Lorenzo Bennati
- Department of Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, Verona 37129, Italy
| | - Christian Vergara
- LABS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta," Politecnico di Milano, Milan 20133, Italy
| | - Maurizio Domanin
- Vascular Surgery Unit, IRCCS, Ospedale Maggiore Policlinico, Milan 20133, Italy; Department of Clinical Sciences and Community Health, University of Milan, Milan 20133, Italy
| | - Chiara Malloggi
- Laboratory of Research in Vascular Surgery, Istituto Auxologico Italiano, IRCCS, Milan 20133, Italy
| | - Daniele Bissacco
- Vascular Surgery Unit, IRCCS, Ospedale Maggiore Policlinico, Milan 20133, Italy
| | - Santi Trimarchi
- Vascular Surgery Unit, IRCCS, Ospedale Maggiore Policlinico, Milan 20133, Italy; Department of Clinical Sciences and Community Health, University of Milan, Milan 20133, Italy
| | - Vincenzo Silani
- Department of Neurology-Stroke Unit and Laboratory of Neuroscience, Ospedale San Luca, Istituto Auxologico Italiano, IRCCS, Milan 20133, Italy; Department of Pathophysiology and Transplantation, University of Milan, Milan 20133, Italy
| | - Gianfranco Parati
- Department of Cardiovascular, Neural and Metabolic Sciences, Ospedale San Luca, Istituto Auxologico Italiano, IRCCS, Milan 20133, Italy; Department of Medicine and Surgery, Università di Milano-Bicocca, Monza 20900, Italy
| | - Renato Casana
- Laboratory of Research in Vascular Surgery, Istituto Auxologico Italiano, IRCCS, Milan 20133, Italy; Department of Surgery, Istituto Auxologico Italiano, IRCCS, Milan 20133, Italy
| |
Collapse
|
18
|
Brady L, Stender CJ, Wang YN, Schade GR, Maxwell AD, Wessells H, Ledoux WR. Mechanical characterization of fibrotic and mineralized tissue in Peyronie's disease. Int J Impot Res 2021; 34:477-486. [PMID: 34035467 DOI: 10.1038/s41443-021-00439-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 02/18/2021] [Accepted: 04/07/2021] [Indexed: 11/09/2022]
Abstract
Peyronie's disease affects penile mechanics, but published research lacks biomechanical characterization of affected tunica albuginea. This work aims to establish mechanical testing methodology and characterize pathological tissue mechanics of Peyronie's disease. Tunica albuginea was obtained from patients (n = 5) undergoing reconstructive surgery for Peyronie's disease, sectioned into test specimens (n = 12), stored frozen at -20 °C, and imaged with micro-computed tomography (µCT). A tensile testing protocol was developed based on similar soft tissues. Correlation of mechanical summary variables (force, displacement, stiffness, work, Young's modulus, ultimate tensile stress, strain at ultimate tensile stress, and toughness) and µCT features were assessed with linear regression. Specimens empirically grouped into hard or soft stress-strain behavior were compared using a Student's t-test. Surface strain and failure patterns were described qualitatively. Specimens displayed high inter- and intra-subject variability. Mineralization volume was not correlated with mechanical parameters. Empirically hard tissue had higher ultimate tensile stress. Failure mechanisms and strain patterns differed between mineralized and non-mineralized specimens. Size, shape, and quantity of mineralization may be more important in determining Peyronie's disease plaque behavior than presence of mineralization alone, and single summary variables like modulus may not fully describe mechanical behavior.
Collapse
Affiliation(s)
- Lynda Brady
- VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, Seattle, WA, USA.,Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Christina J Stender
- VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, Seattle, WA, USA
| | - Yak-Nam Wang
- VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, Seattle, WA, USA.,Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - George R Schade
- Department of Urology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Adam D Maxwell
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA.,Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA.,Department of Urology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Hunter Wessells
- Department of Urology, School of Medicine, University of Washington, Seattle, WA, USA
| | - William R Ledoux
- VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, Seattle, WA, USA. .,Department of Mechanical Engineering, University of Washington, Seattle, WA, USA. .,Department of Orthopaedics & Sports Medicine, University of Washington, Seattle, WA, USA.
| |
Collapse
|
19
|
Johnston RD, Gaul RT, Lally C. An investigation into the critical role of fibre orientation in the ultimate tensile strength and stiffness of human carotid plaque caps. Acta Biomater 2021; 124:291-300. [PMID: 33571712 DOI: 10.1016/j.actbio.2021.02.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 01/28/2021] [Accepted: 02/03/2021] [Indexed: 01/02/2023]
Abstract
The development and subsequent rupture of atherosclerotic plaques in human carotid arteries is a major cause of ischaemic stroke. Mechanical characterization of atherosclerotic plaques can aid our understanding of this rupture risk. Despite this however, experimental studies on human atherosclerotic carotid plaques, and fibrous plaque caps in particular, are very limited. This study aims to provide further insights into atherosclerotic plaque rupture by mechanically testing human fibrous plaque caps, the region of the atherosclerotic lesion most often attributed the highest risk of rupture. The results obtained highlight the variability in the ultimate tensile stress, strain and stiffness experienced in atherosclerotic plaque caps. By pre-screening all samples using small angle light scattering (SALS) to determine the dominant fibre direction in the tissue, along with supporting histological analysis, this work suggests that the collagen fibre alignment in the circumferential direction plays the most dominant role for determining plaque structural stability. The work presented in this study could provide the basis for new diagnostic approaches to be developed, which non-invasively identify carotid plaques at greatest risk of rupture. STATEMENT OF SIGNIFICANCE: Mechanical characterisation of the atherosclerotic plaque cap is of utmost importance for understanding the mechanisms that govern the rupture strength of this tissue in-vivo. Studies has shown that plaque tissue is heterogenous and comprises of many structural components, each of which exhibits a varying mechanical response. However, rupture generally is located to the plaque cap, whereby the stress exerted on this location exceeds its mechanical strength causing failure. This work shows, for the first time, that the underlying collagen fibre architecture of carotid plaque caps governs their strength and stiffness. This study shows that plaque caps with collagen fibres aligned in the predominately circumferential direction experience higher stresses and lower strains before failure while those with predominately axial fibres display the opposite trend. Furthermore, total collagen content was found not to play a dominant role in determining the mechanical response of the tissue. The present study provides critical insights into human atherosclerotic plaque tissue mechanics and offers clinically relevant insights for mechanically sensitive imaging techniques, such as strain-based ultrasound or MRI.
Collapse
|
20
|
Helou B, Bel-Brunon A, Dupont C, Ye W, Silvestro C, Rochette M, Lucas A, Kaladji A, Haigron P. The influence of angioplasty balloon sizing on acute post-procedural outcomes: a Finite Element Analysis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2536-2539. [PMID: 33018523 DOI: 10.1109/embc44109.2020.9176740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Atherosclerosis is one of the most common vascular pathologies in the world. Among the most commonly performed endovascular treatments, percutaneous transluminal angioplasty (PTA) has been showing significantly positive clinical outcomes. Due to the complex geometries, material properties and interactions that characterize PTA procedures, finite element analyses of acute angioplasty balloon deployment are limited. In this work, finite element method (FEM) was used to simulate the inflation and deflation of a semi-compliant balloon within the 3D model of a stenosed artery with two different plaque types (lipid and calcified). Self-defined constitutive models for the balloon and the plaque were developed based on experimental and literature data respectively. Balloon deployment was simulated at three different inflation pressures (10, 12 and 14 atm) within the two plaque types. Balloon sizing influence on the arterial elastic recoil obtained immediately after PTA was then investigated. The simulated results show that calcified plaques may lead to higher elastic recoil ratios compared to lipid stenosis, when the same balloon inflation pressures are applied. Also, elastic recoil increases for higher balloon inflation pressure independent of the plaque type. These findings open the way for a data-driven assessment of angioplasty balloon sizing selection and clinical procedures optimization.Clinical Relevance- The FE model developed in this work aims at providing quantitative evaluation of recoil after balloon angioplasty. It may be useful for both manufacturers and clinicians to improve efficiency of angioplasty balloon device design and sizing selection with respect to plaque geometry and constitution, consequently enhancing clinical outcomes.
Collapse
|
21
|
Noble C, Carlson K, Neumann E, Lewis B, Dragomir-Daescu D, Lerman A, Erdemir A, Young M. Ex Vivo Evaluation of IVUS-VH Imaging and the Role of Plaque Structure on Peripheral Artery Disease. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2020; 8. [PMID: 34291202 DOI: 10.1016/j.medntd.2020.100042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Peripheral artery disease (PAD) results from the buildup of atherosclerotic plaque in the arterial wall, can progress to severe ischemia and lead to tissue necrosis and limb amputation. We evaluated a means of assessing PAD mechanics ex vivo using ten human peripheral arteries with PAD. Pressure-inflation testing was performed at six physiological pressure intervals ranging from 10-200 mmHg. These vessels were imaged with IVUS-VH to determine plaque composition and change in vessel structure with pressure. Statistical analysis was performed to determine which plaque structures and distributions of these structures had the greatest influence on wall deformation. We found that fibrous plaque, necrotic core, and calcification had a statistically significant effect on all variables (p<0.05). The presence of large concentrations of fibrous plaque was linked to reduced vessel compliance and ellipticity, which could lead to stent fractures and restenosis. For the plaque distribution we found that clustered necrotic core increased overall compliance while clustered calcification decreased overall compliance. The effect of plaque distribution on vessel wall deformation must be considered equally important to plaque concentration.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Kent Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Erica Neumann
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Bradley Lewis
- Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Ahmet Erdemir
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Melissa Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
22
|
O'Reilly BL, Hynes N, Sultan S, McHugh PE, McGarry JP. An experimental and computational investigation of the material behaviour of discrete homogenous iliofemoral and carotid atherosclerotic plaque constituents. J Biomech 2020; 106:109801. [DOI: 10.1016/j.jbiomech.2020.109801] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 02/28/2020] [Accepted: 04/14/2020] [Indexed: 12/23/2022]
|
23
|
BHAT SUBRAYAKRISHNA, SAKATA NORIYUKI, YAMADA HIROSHI. IDENTIFICATION OF UNIAXIAL DEFORMATION BEHAVIOR AND ITS INITIAL TANGENT MODULUS FOR ATHEROMATOUS INTIMA IN THE HUMAN CAROTID ARTERY AND THORACIC AORTA USING THREE-PARAMETER ISOTROPIC HYPERELASTIC MODELS. J MECH MED BIOL 2020. [DOI: 10.1142/s0219519420500141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Uniaxial stretching tests are used for mechanical identification of small fibrous regions of atheromatous arteries. Material constants in isotropic hyperelastic models are determined to minimize the fitting error for the stress–strain curve. We developed a novel method to better characterize the material constants in typical forms of Yeoh, Ogden, Chuong–Fung (CF) and Gasser–Ogden–Holzapfel (GOH) isotropic hyperelastic models for fibrous caps and normal intimal layers from human carotid artery and thoracic aorta by incorporating Young’s modulus, i.e., the initial tangent modulus of uniaxial stress–strain relationships, as one of three material constants. We derived a unified, isotropic form for the anisotropic exponential-type strain energy density functions of CF and GOH models. The uniaxial stress–strain relationship equations were expanded to Maclaurin series to identify Young’s modulus as a coefficient of the linear term of the strain and to examine the roles of the material constants in the nonlinear function. The remaining two material constants were determined by curvefitting. The incorporation of Young’s modulus into the CF and GOH models gave reasonable curvefitting, with errors [Formula: see text], whereas large errors ([Formula: see text]) were observed in one case for the Yeoh model and in two cases for the Ogden model.
Collapse
Affiliation(s)
- SUBRAYA KRISHNA BHAT
- Department of Biological Functions Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
| | - NORIYUKI SAKATA
- Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan
| | - HIROSHI YAMADA
- Department of Biological Functions Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
| |
Collapse
|
24
|
Mechanical and structural properties of different types of human aortic atherosclerotic plaques. J Mech Behav Biomed Mater 2020; 109:103837. [PMID: 32543403 DOI: 10.1016/j.jmbbm.2020.103837] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 04/16/2020] [Accepted: 04/26/2020] [Indexed: 11/23/2022]
Abstract
Atherosclerotic plaques are characterized by structural heterogeneity affecting aortic behaviour under mechanical loading. There is evidence of direct connections between the structural plaque arrangement and the risk of plaque rupture. As a consequence of aortic plaque rupture, plaque components are transferred by the bloodstream to smaller vessels, resulting in acute cardiovascular events with a poor prognosis, such as heart attacks or strokes. Hence, evaluation of the composition, structure, and biochemical profile of atherosclerotic plaques seems to be of great importance to assess the properties of a mechanically induced failure, indicating the strength and rupture vulnerability of plaque. The main goal of the research was to determine experimentally under uniaxial loading the mechanical properties of different types of the human abdominal aorta and human aortic atherosclerotic plaques identified based on vibrational spectra (ATR-FTIR and FT-Raman spectroscopy) analysis and validated by histological staining. The potential of spectroscopic techniques as a useful histopathological tool was demonstrated. Three types of atherosclerotic plaques - predominantly calcified (APC), lipid (APL), and fibrotic (APF) - were distinguished and confirmed by histopathological examinations. Compared to the normal aorta, fibrotic plaques were stiffer (median of EH for circumferential and axial directions, respectively: 8.15 MPa and 6.56 MPa) and stronger (median of σM for APLc = 1.57 MPa and APLa = 1.64 MPa), lipidic plaques were the weakest (median of σM for APLc = 0.76 MPa and APLa = 0.51 MPa), and calcified plaques were the stiffest (median of EH for circumferential and axial directions, respectively: 13.23 MPa and 6.67 MPa). Therefore, plaques detected as predominantly lipid and calcified are most prone to rupture; however, the failure process reflected by the simplification of the stress-stretch characteristics seems to vary depending on the plaque composition.
Collapse
|
25
|
Paritala PK, Yarlagadda PKDV, Kansky R, Wang J, Mendieta JB, Gu Y, McGahan T, Lloyd T, Li Z. Stress-Relaxation and Cyclic Behavior of Human Carotid Plaque Tissue. Front Bioeng Biotechnol 2020; 8:60. [PMID: 32117939 PMCID: PMC7026010 DOI: 10.3389/fbioe.2020.00060] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 01/23/2020] [Indexed: 12/12/2022] Open
Abstract
Atherosclerotic plaque rupture is a catastrophic event that contributes to mortality and long-term disability. A better understanding of the plaque mechanical behavior is essential for the identification of vulnerable plaques pre-rupture. Plaque is subjected to a natural dynamic mechanical environment under hemodynamic loading. Therefore, it is important to understand the mechanical response of plaque tissue under cyclic loading conditions. Moreover, experimental data of such mechanical properties are fundamental for more clinically relevant biomechanical modeling and numerical simulations for risk stratification. This study aims to experimentally and numerically characterize the stress-relaxation and cyclic mechanical behavior of carotid plaque tissue. Instron microtester equipped with a custom-developed setup was used for the experiments. Carotid plaque samples excised at endarterectomy were subjected to uniaxial tensile, stress-relaxation, and cyclic loading protocols. Thirty percent of the underlying load level obtained from the uniaxial tensile test results was used to determine the change in mechanical properties of the tissue over time under a controlled testing environment (Control tests). The stress-relaxation test data was used to calibrate the hyperelastic (neo-Hookean, Ogden, Yeoh) and linear viscoelastic (Prony series) material parameters. The normalized relaxation force increased initially and slowly stabilized toward the end of relaxation phase, highlighting the viscoelastic behavior. During the cyclic tests, there was a decrease in the peak force as a function of the cycle number indicating mechanical distension due to repeated loading that varied with different frequencies. The material also accumulated residual deformation, which increased with the cycle number. This trend showed softening behavior of the samples. The results of this preliminary study provide an enhanced understanding of in vivo stress-relaxation and cyclic behavior of the human atherosclerotic plaque tissue.
Collapse
Affiliation(s)
- Phani Kumari Paritala
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Prasad K D V Yarlagadda
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Rhys Kansky
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Jiaqiu Wang
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Jessica Benitez Mendieta
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - YuanTong Gu
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Tim McGahan
- Department of Vascular Surgery, Princess Alexandra Hospital, Brisbane, QLD, Australia
| | - Thomas Lloyd
- Department of Radiology, Princess Alexandra Hospital, Brisbane, QLD, Australia
| | - Zhiyong Li
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
26
|
Sanders SN, Lopata RGP, van Breemen LCA, van de Vosse FN, Rutten MCM. A novel technique for the assessment of mechanical properties of vascular tissue. Biomech Model Mechanobiol 2020; 19:1585-1594. [PMID: 31980973 PMCID: PMC7502444 DOI: 10.1007/s10237-020-01292-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 01/14/2020] [Indexed: 11/28/2022]
Abstract
Accurate estimation of mechanical properties of the different atherosclerotic plaque constituents is important in assessing plaque rupture risk. The aim of this study was to develop an experimental set-up to assess material properties of vascular tissue, while applying physiological loading and being able to capture heterogeneity. To do so, a ring-inflation experimental set-up was developed in which a transverse slice of an artery was loaded in the radial direction, while the displacement was estimated from images recorded by a high-speed video camera. The performance of the set-up was evaluated using seven rubber samples and validated with uniaxial tensile tests. For four healthy porcine carotid arteries, material properties were estimated using ultrasound strain imaging in whole-vessel-inflation experiments and compared to the properties estimated with the ring-inflation experiment. A 1D axisymmetric finite element model was used to estimate the material parameters from the measured pressures and diameters, using a neo-Hookean and Holzapfel–Gasser–Ogden material model for the rubber and porcine samples, respectively. Reproducible results were obtained with the ring-inflation experiment for both rubber and porcine samples. Similar mean stiffness values were found in the ring-inflation and tensile tests for the rubber samples as 202 kPa and 206 kPa, respectively. Comparable results were obtained in vessel-inflation experiments using ultrasound and the proposed ring-inflation experiment. This inflation set-up is suitable for the assessment of material properties of healthy vascular tissue in vitro. It could also be used as part of a method for the assessment of heterogeneous material properties, such as in atherosclerotic plaques.
Collapse
Affiliation(s)
- Stefan N Sanders
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB, Eindhoven, The Netherlands.
| | - Richard G P Lopata
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB, Eindhoven, The Netherlands
| | - Lambert C A van Breemen
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB, Eindhoven, The Netherlands
| |
Collapse
|
27
|
Noble C, Carlson KD, Neumann E, Dragomir-Daescu D, Erdemir A, Lerman A, Young M. Patient specific characterization of artery and plaque material properties in peripheral artery disease. J Mech Behav Biomed Mater 2019; 101:103453. [PMID: 31585351 DOI: 10.1016/j.jmbbm.2019.103453] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 09/24/2019] [Accepted: 09/25/2019] [Indexed: 12/19/2022]
Abstract
Patient-specific finite element (FE) modeling of atherosclerotic plaque is challenging, as there is limited information available clinically to characterize plaque components. This study proposes that for the limited data available in vivo, material properties of plaque and artery can be identified using inverse FE analysis and either a simple neo-Hookean constitutive model or assuming linear elasticity provides sufficient accuracy to capture the changes in vessel deformation, which is the available clinical metric. To test this, 10 human cadaveric femoral arteries were each pressurized ex vivo at 6 pressure levels, while intravascular ultrasound (IVUS) and virtual histology (VH) imaging were performed during controlled pull-back to determine vessel geometry and plaque structure. The VH images were then utilized to construct FE models with heterogeneous material properties corresponding to the vessel plaque components. The constitutive models were then fit to each plaque component by minimizing the difference between the experimental and the simulated geometry using the inverse FE method. Additionally, we further simplified the analysis by assuming the vessel wall had a homogeneous structure, i.e. lumping artery and plaque as one tissue. We found that for the heterogeneous wall structure, the simulated and experimental vessel geometries compared well when the fitted neo-Hookean parameters or elastic modulus, in the case of linear elasticity, were utilized. Furthermore, taking the median of these fitted parameters then inputting these as plaque component mechanical properties in the finite element simulation yielded differences between simulated and experimental geometries that were on average around 2% greater (1.30-5.55% error range to 2.33-11.71% error range). For the homogeneous wall structure the simulated and experimental wall geometries had an average difference of around 4% although when the difference was calculated using the median fitted value this difference was larger than for the heterogeneous fits. Finally, comparison to uniaxial tension data and to literature constitutive models also gave confidence to the suitability of this simplified approach for patient-specific arterial simulation based on data that may be acquired in the clinic.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Kent D Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Erica Neumann
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Ahmet Erdemir
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Melissa Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
28
|
Barrett HE, Van der Heiden K, Farrell E, Gijsen FJH, Akyildiz AC. Calcifications in atherosclerotic plaques and impact on plaque biomechanics. J Biomech 2019; 87:1-12. [PMID: 30904335 DOI: 10.1016/j.jbiomech.2019.03.005] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 03/09/2019] [Indexed: 12/13/2022]
Abstract
The catastrophic mechanical rupture of an atherosclerotic plaque is the underlying cause of the majority of cardiovascular events. The infestation of vascular calcification in the plaques creates a mechanically complex tissue composite. Local stress concentrations and plaque tissue strength properties are the governing parameters required to predict plaque ruptures. Advanced imaging techniques have permitted insight into fundamental mechanisms driving the initiating inflammatory-driven vascular calcification of the diseased intima at the (sub-) micron scale and up to the macroscale. Clinical studies have potentiated the biomechanical relevance of calcification through the derivation of links between local plaque rupture and specific macrocalcification geometrical features. The clinical implications of the data presented in this review indicate that the combination of imaging, experimental testing, and computational modelling efforts are crucial to predict the rupture risk for atherosclerotic plaques. Specialised experimental tests and modelling efforts have further enhanced the knowledge base for calcified plaque tissue mechanical properties. However, capturing the temporal instability and rupture causality in the plaque fibrous caps remains elusive. Is it necessary to move our experimental efforts down in scale towards the fundamental (sub-) micron scales in order to interpret the true mechanical behaviour of calcified plaque tissue interactions that is presented on a macroscale in the clinic and to further optimally assess calcified plaques in the context of biomechanical modelling.
Collapse
Affiliation(s)
- Hilary E Barrett
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands.
| | - Kim Van der Heiden
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Eric Farrell
- Department of Oral and Maxillofacial Surgery, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Frank J H Gijsen
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Ali C Akyildiz
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
29
|
Rezvani-Sharif A, Tafazzoli-Shadpour M, Avolio A. Progressive changes of elastic moduli of arterial wall and atherosclerotic plaque components during plaque development in human coronary arteries. Med Biol Eng Comput 2018; 57:731-740. [PMID: 30374700 DOI: 10.1007/s11517-018-1910-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 10/03/2018] [Indexed: 12/14/2022]
Abstract
Stiffness of the arterial wall and atherosclerotic plaque components is a determinant of the stress field within plaques, which has been suggested to be an indicator of plaque vulnerability. The diversity and inhomogeneous structure of atherosclerotic lesions complicate the characterization of plaque components. In the present study, stiffness of the arterial wall and atherosclerotic plaque components in human coronary arteries was examined in early and developed atherosclerotic lesions. The force-spectroscopy mode of the atomic force microscope and histological examination were used for determination of elastic moduli at specified locations within samples. Fibrous cap (E = 14.1 ± 3.8 kPa) showed lower stiffness than the fibrous tissue beneath the lipid pool (E = 17.6 ± 3.2 kPa). Calcification zones (E = 96.1 ± 18.8 kPa) and lipid pools (E = 2.7 ± 1.8 kPa) were the stiffest and softest components of atherosclerotic lesions, respectively. The increase of media stiffness (%44.8) and reduction of the elastic modulus of the internal elastic lamina (%28.9) was observed in coronary arteries. Moreover, significant differences were observed between the stiffness of medial layer in diseased parts and free-plaque segments in incomplete plaques of coronary arteries. Our results can be used for better understanding of remodeling mechanisms of the arterial wall with plaque development. Graphical abstract Stiffness alteration of the arterial wall and atherosclerotic plaque components with plaque development in coronary arteries.
Collapse
Affiliation(s)
- Alireza Rezvani-Sharif
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Hafez Street, Tehran, Iran.,Department of Biomedical Science, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW, 2109, Australia
| | | | - Alberto Avolio
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Hafez Street, Tehran, Iran
| |
Collapse
|
30
|
Cahalane RM, Barrett HE, O'Brien JM, Kavanagh EG, Moloney MA, Walsh MT. Relating the mechanical properties of atherosclerotic calcification to radiographic density: A nanoindentation approach. Acta Biomater 2018; 80:228-236. [PMID: 30218776 DOI: 10.1016/j.actbio.2018.09.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 09/04/2018] [Accepted: 09/11/2018] [Indexed: 12/20/2022]
Abstract
Calcification morphology can determine atherosclerotic plaque stability and is associated with increased failures rates for endovascular interventions. Computational efforts have sought to elucidate the relationship between calcification and plaque rupture in addition to predicting tissue response during aggressive revascularisation techniques. However, calcified material properties are currently estimated and may not reflect real tissue conditions. The objective of this study is to correlate calcification mechanical properties with three radiographic density groups obtained from corresponding Computed Tomography (CT) images. Seventeen human plaques extracted from carotid (n = 10) and peripheral lower limb (n = 7) arteries were examined using micro-computed tomography (µCT), simultaneously locating the calcified deposits within their internal structure and quantifying their densities. Three radiographic density groups were defined based on the sample density distribution: (A) 130-299.99 Hounsfield Units (HU), (B) 300-449.99 HU and (C) >450 HU. Nanoindentation was employed to determine the Elastic Modulus (E) and Hardness (H) values within the three density groups. Results reveal a clear distinction between mechanical properties with respect to radiographic density groups (p < 0.0005). No significant differences exist in the density-specific behaviours observed between carotid and peripheral samples. Previously defined calcification classifications indicate an association with specific radiographic density patterns. Scanning Electron Microscopy (SEM) examination revealed that density group A regions consist of both calcified and non-calcified tissues. Further research is required to define the radiographic thresholds which identify varying degrees of tissue calcification. This study demonstrates that the mechanical properties of fully mineralised atherosclerotic calcification emulate that of bone tissues (17-25 GPa), affording computational models with accurate material parameters. STATEMENT OF SIGNIFICANCE: Global mechanical characterisation techniques disregard the heterogeneous nature of atherosclerotic lesions. Previous nanoindentation results for carotid calcifications have displayed a wide range. This study evaluates calcification properties with respect to radiographic density obtained from Micro-CT images. This is the first work to characterise calcifications from peripheral lower limb arteries using nanoindentation. Results demonstrate a strong positive correlation between radiographic density and calcification mechanical properties. Characterising calcifications using their density values provides clarity on the variation in published properties for calcified tissues. Furthermore, this study confirms the hypothesis that fully calcified plaque tissue behaviour similar to that of bone. Appropriate material parameters for calcified tissues can now be employed in computational simulations.
Collapse
|
31
|
Rezvani-Sharif A, Tafazzoli-Shadpour M, Avolio A. Mechanical Characterization of the Lamellar Structure of Human Abdominal Aorta in the Development of Atherosclerosis: An Atomic Force Microscopy Study. Cardiovasc Eng Technol 2018; 10:181-192. [PMID: 30006817 DOI: 10.1007/s13239-018-0370-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 07/08/2018] [Indexed: 12/16/2022]
Abstract
Atherosclerosis is a major risk factor for cardiovascular disease. However, mechanisms of interaction of atherosclerotic plaque development and local stiffness of the lamellar structure of the arterial wall are not well established. In the current study, the local Young's modulus of the wall and plaque components were determined for three different groups of healthy, mildly diseased and advanced atherosclerotic human abdominal aortas. Histological staining was performed to highlight the atherosclerotic plaque components and lamellar structure of the aortic media, consisting of concentric layers of elastin and interlamellar zones. The force spectroscopy mode of the atomic force microscopy was utilized to determine Young's moduli of aortic wall lamellae and plaque components at the micron level. The high variability of Young's moduli (E) at different locations of the atherosclerotic plaque such as the fibrous cap (E = 15.5± 2.6 kPa), calcification zone (E = 103.7±19.5 kPa), and lipid pool (E = 3.5±1.2 kPa) were observed. Reduction of elastin lamellae stiffness (18.6%), as well as stiffening of interlamellar zones (50%), were detected in the diseased portion of the medial layer of abdominal aortic wall compared to the healthy artery. Additionally, significant differences in the stiffness of both elastin lamellae and interlamellar zones were observed between the diseased wall and disease-free wall in incomplete plaques. Our results elucidate the alternation of the stiffness of different lamellae in the human abdominal aortic wall with atherosclerotic plaque development and may provide new insight on the remodeling of the aortic wall during the progression of atherosclerosis.
Collapse
Affiliation(s)
- Alireza Rezvani-Sharif
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.,Department of Biomedical Science, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | | | - Alberto Avolio
- Department of Biomedical Science, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
32
|
Hoffman AH, Teng Z, Zheng J, Wu Z, Woodard PK, Billiar KL, Wang L, Tang D. Stiffness Properties of Adventitia, Media, and Full Thickness Human Atherosclerotic Carotid Arteries in the Axial and Circumferential Directions. J Biomech Eng 2018; 139:2653366. [PMID: 28857112 DOI: 10.1115/1.4037794] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Indexed: 11/08/2022]
Abstract
Arteries can be considered as layered composite material. Experimental data on the stiffness of human atherosclerotic carotid arteries and their media and adventitia layers are very limited. This study used uniaxial tests to determine the stiffness (tangent modulus) of human carotid artery sections containing American Heart Association type II and III lesions. Axial and circumferential oriented adventitia, media, and full thickness specimens were prepared from six human carotid arteries (total tissue strips: 71). Each artery yielded 12 specimens with two specimens in each of the following six categories; axial full thickness, axial adventitia (AA), axial media (AM), circumferential full thickness, circumferential adventitia (CA), and circumferential media (CM). Uniaxial testing was performed using Inspec 2200 controlled by software developed using labview. The mean stiffness of the adventitia was 3570 ± 667 and 2960 ± 331 kPa in the axial and circumferential directions, respectively, while the corresponding values for the media were 1070 ± 186 and 1800 ± 384 kPa. The adventitia was significantly stiffer than the media in both the axial (p = 0.003) and circumferential (p = 0.010) directions. The stiffness of the full thickness specimens was nearly identical in the axial (1540 ± 186) and circumferential (1530 ± 389 kPa) directions. The differences in axial and circumferential stiffness of media and adventitia were not statistically significant.
Collapse
Affiliation(s)
- Allen H Hoffman
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609
| | - Zhongzhao Teng
- Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609.,Department of Radiology, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Jie Zheng
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110
| | - Zheyang Wu
- Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609
| | - Pamela K Woodard
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110
| | - Kristen L Billiar
- Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609
| | - Liang Wang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Dalin Tang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.,Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA 01609 e-mail:
| |
Collapse
|
33
|
Syaifudin A, Takeda R, Sasaki K. Development of asymmetric stent for treatment of eccentric plaque. Biomed Mater Eng 2018; 29:299-317. [PMID: 29578470 DOI: 10.3233/bme-181737] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat eccentric plaque using structural transient dynamic analysis in ANSYS. A non-symmetric structural geometry of stent is generated to obtain reasonable stress distribution safe for the arterial layer surrounding the stent. To derive the novel structural geometry, a Sinusoidal stent type is modified by varying struts length and width, adding bridges, and varying curvature width of struts. An end ring of stent struts was also modified to eliminate dogboning phenomenon and to reduce the Ectropion angle. Two balloon types were used to deploy the stent, an ordinary cylindrical and offset balloon. Positive modification results were used to construct the final non-symmetric stent design, called an Asymmetric stent. Analyses of the deformation characteristics, changes in surface roughness and induced stresses within intact arterial layer were subsequently examined. Interaction between the stent and vessel wall was implemented by means of changes in surface roughness and stress distribution analyses. The Palmaz and the Sinusoidal stent were used for a comparative study. This study indicated that the Asymmetric stent types reduced the central radial recoiling and the dogboning phenomenon. In terms of changes in surface roughness and induced stresses, the Asymmetric stent has a comparable effect with that of the Sinusoidal stent. In addition, it could enhance the distribution of surface roughening as expanded by an offset balloon.
Collapse
Affiliation(s)
- Achmad Syaifudin
- Department of Mechanical Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia
| | - Ryo Takeda
- Division of Human Mechanical Systems and Design, Faculty of Engineering, Hokkaido University, Sapporo, Japan
| | - Katsuhiko Sasaki
- Division of Human Mechanical Systems and Design, Faculty of Engineering, Hokkaido University, Sapporo, Japan
| |
Collapse
|
34
|
Fan Z, Liu X, Sun A, Zhang N, Fan Z, Fan Y, Deng X. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques. Med Eng Phys 2017; 48:114-119. [DOI: 10.1016/j.medengphy.2017.06.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 05/23/2017] [Accepted: 06/02/2017] [Indexed: 12/01/2022]
|
35
|
Talaska K, Ferreira A. An Approach to Identifying Phenomena Accompanying Micro and Nanoparticles in Contact With Irregular Vessel Walls. IEEE Trans Nanobioscience 2017. [PMID: 28641266 DOI: 10.1109/tnb.2017.2717178] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The objective of this paper is to present the method for determining the nature and values of the forces needed to set micro and nanoparticles sitting immobile at the blood vessel wall in motion. The problem was tackled in two ways. Microparticles were examined as objects coming into contact with the wall with the actual large arteriole-type vessel structure. The forces acting on microparticles 10, 30, and [Formula: see text] in diameter were determined: drag force FD , lift force FL , electrostatic force FE , and gravity force FG . Fluid-structure interaction analysis was used to research the problem. However, nanoparticles were examined as objects coming into contact with the endothelial surface layer (ESL). Resistance forces during the movement of nanoparticles 20, 50, and 100 nm in diameter in the ESL were determined. The same was done for aggregates of nanoparticles 50 nm in diameter. Local irregularities in wall surface are important for microparticles. Small irregularities with the small values of electrostatic force FE can effectively stop the particle. In the case of nanoparticles, the key is the interaction of the particle with ESL. The research methodology presented can be used to better understand the particle-blood vessel wall interaction phenomena, leading to a more informed particle movement control. The new application of known calculation methods presented in this paper can be successfully used as an additional tool that simplifies planning and design of strategies for drug delivery by means of micro and nanoparticles.
Collapse
|
36
|
Deokar RR, Klamecki BE. Computational Modeling and Comparative Tissue Damage Analysis of Angioplasty and Orbital Atherectomy Interventional Procedures. J Med Device 2017. [DOI: 10.1115/1.4036299] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
This research was directed toward quantitatively characterizing the effects of arterial mechanical treatment procedures on the stress and strain energy states of the artery wall. Finite element simulations of percutaneous transluminal angioplasty (PTA) and orbital atherectomy (OA) were performed on arterial lesion models with various extents and types of plaque. Stress fields in the artery were calculated and strain energy density was used as an explicit description of potential damage to the artery. The research also included numerical simulations of changes in arterial compliance due to orbital atherectomy. The angioplasty simulations show that the damage energy fields in the media and adventitia are predominant in regions of the lesion that are not protected by a layer of calcification. In addition, it was observed that softening the plaque components leads to a lower peak stress and therefore lesser damage energy in the media and adventitia under the action of a semicompliant balloon. Orbital atherectomy simulations revealed that the major portion of strain energy dissipated is concentrated in the plaque components in contact with the spinning tool. The damage and peak stress fields in the media and adventitia components of the vessel were significantly less. This observation suggests less mechanically induced trauma during a localized procedure like orbital atherectomy. Artery compliance was calculated pre- and post-treatment and an increase was observed after the orbital atherectomy procedure. The localized plaque disruption produced in atherectomy suggests that the undesirable stress states in angioplasty can be mitigated by a combination of procedures such as atherectomy followed by angioplasty.
Collapse
Affiliation(s)
- Rohit R. Deokar
- Department of Mechanical Engineering, University of Minnesota—Twin Cities, 111 Church Street SE, Minneapolis, MN 55455 e-mail:
| | - Barney E. Klamecki
- Department of Mechanical Engineering, University of Minnesota—Twin Cities, 111 Church Street SE, Minneapolis, MN 55455 e-mail:
| |
Collapse
|
37
|
Kondo K, Nemoto M, Harada N, Fukushima D, Masuda H, Sugo N. Comparison between Quantitative Stiffness Measurements and Ultrasonographic Findings of Fresh Carotid Plaques. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:138-144. [PMID: 27692874 DOI: 10.1016/j.ultrasmedbio.2016.08.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Revised: 06/13/2016] [Accepted: 08/12/2016] [Indexed: 06/06/2023]
Abstract
Using a stiffness meter, we quantitatively measured the stiffness of fresh plaques that had been excised by carotid endarterectomy. The objective of this study was to clarify the correlation between plaque stiffness and pre-operative carotid ultrasonographic findings, and predict the stiffness of plaques before surgery by comparison with the stiffness of common items. The study population comprised 44 patients (44 lesions) who had undergone carotid endarterectomy at our institution between December 2009 and October 2014. The stiffness of excised fresh plaques was measured using a stiffness meter and compared with the pre-operative echographic findings for the plaques and the stiffness of selected foods and common items. The mean stiffness value for all plaques was 4.52 ± 3.30 MPa (mean ± standard deviation). The plaques exhibiting calcification were significantly harder (p = 0.001). On classification of lesions on the basis of echographic findings, plaque hardness was in the order low-echoic (15 lesions) < iso-echoic (20 lesions) < high-echoic (9 lesions) (p = 0.02). The stiffness of the low-echoic group was equivalent to that of tofu or sliced cheese, whereas the plaques in the iso- and high-echoic groups exhibited stiffness similar to that of ham and a plastic eraser, respectively. A significant correlation was observed between the quantitative stiffness values of carotid plaques and their brightness on carotid ultrasonography. Using these data, operators might be able to predict plaque stiffness from pre-operative echographic findings. In addition, it might be useful for operators to compare such quantitative stiffness measurements with stiffness data for foods and common items to gain an understanding of the state of the target plaque before treatment.
Collapse
Affiliation(s)
- Kosuke Kondo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan.
| | - Masaaki Nemoto
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan
| | - Naoyuki Harada
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan
| | - Daisuke Fukushima
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan
| | - Hiroyuki Masuda
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan
| | - Nobuo Sugo
- Department of Neurosurgery (Omori), School of Medicine, Faculty of Medicine, Toho University, Ota-ku, Tokyo, Japan
| |
Collapse
|
38
|
Boekhoven RW, Peters MFJ, Rutten MCM, van Sambeek MR, van de Vosse FN, Lopata RGP. Inflation and Bi-Axial Tensile Testing of Healthy Porcine Carotid Arteries. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:574-585. [PMID: 26598396 DOI: 10.1016/j.ultrasmedbio.2015.09.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 09/16/2015] [Accepted: 09/16/2015] [Indexed: 06/05/2023]
Abstract
Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.
Collapse
Affiliation(s)
- Renate W Boekhoven
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Mathijs F J Peters
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marc R van Sambeek
- Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Richard G P Lopata
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
39
|
Teng Z, Yuan J, Feng J, Zhang Y, Brown AJ, Wang S, Lu Q, Gillard JH. The influence of constitutive law choice used to characterise atherosclerotic tissue material properties on computing stress values in human carotid plaques. J Biomech 2015; 48:3912-21. [PMID: 26472305 PMCID: PMC4655867 DOI: 10.1016/j.jbiomech.2015.09.023] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 09/16/2015] [Accepted: 09/24/2015] [Indexed: 01/01/2023]
Abstract
Calculating high stress concentration within carotid atherosclerotic plaques has been shown to be complementary to anatomical features in assessing vulnerability. Reliability of stress calculation may depend on the constitutive laws/strain energy density functions (SEDFs) used to characterize tissue material properties. Different SEDFs, including neo-Hookean, one-/two-term Ogden, Yeoh, 5-parameter Mooney–Rivlin, Demiray and modified Mooney–Rivlin, have been used to describe atherosclerotic tissue behavior. However, the capacity of SEDFs to fit experimental data and the difference in the stress calculation remains unexplored. In this study, seven SEDFs were used to fit the stress–stretch data points of media, fibrous cap, lipid and intraplaque hemorrhage/thrombus obtained from 21 human carotid plaques. Semi-analytic solution, 2D structure-only and 3D fully coupled fluid-structure interaction (FSI) analyses were used to quantify stress using different SEDFs and the related material stability examined. Results show that, except for neo-Hookean, all other six SEDFs fitted the experimental points well, with vessel stress distribution in the circumferential and radial directions being similar. 2D structural-only analysis was successful for all seven SEDFs, but 3D FSI were only possible with neo-Hookean, Demiray and modified Mooney–Rivlin models. Stresses calculated using Demiray and modified Mooney–Rivlin models were nearly identical. Further analyses indicated that the energy contours of one-/two-term Ogden and 5-parameter Mooney–Rivlin models were not strictly convex and the material stability indictors under homogeneous deformations were not always positive. In conclusion, considering the capacity in characterizing material properties and stabilities, Demiray and modified Mooney–Rivlin SEDF appear practical choices for mechanical analyses to predict the critical mechanical conditions within carotid atherosclerotic plaques.
Collapse
Affiliation(s)
- Zhongzhao Teng
- Department of Radiology, University of Cambridge, UK; Department of Engineering, University of Cambridge, UK.
| | - Jianmin Yuan
- Department of Radiology, University of Cambridge, UK
| | - Jiaxuan Feng
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | - Yongxue Zhang
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | - Adam J Brown
- Division of Cardiovascular Medicine, University of Cambridge, UK
| | - Shuo Wang
- Department of Radiology, University of Cambridge, UK
| | - Qingsheng Lu
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | | |
Collapse
|
40
|
Teng Z, Feng J, Zhang Y, Sutcliffe MPF, Huang Y, Brown AJ, Jing Z, Lu Q, Gillard JH. A uni-extension study on the ultimate material strength and extreme extensibility of atherosclerotic tissue in human carotid plaques. J Biomech 2015; 48:3859-67. [PMID: 26472304 PMCID: PMC4655866 DOI: 10.1016/j.jbiomech.2015.09.037] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2015] [Revised: 09/16/2015] [Accepted: 09/24/2015] [Indexed: 12/26/2022]
Abstract
Atherosclerotic plaque rupture occurs when mechanical loading exceeds its material strength. Mechanical analysis has been shown to be complementary to the morphology and composition for assessing vulnerability. However, strength and stretch thresholds for mechanics-based assessment are currently lacking. This study aims to quantify the ultimate material strength and extreme extensibility of atherosclerotic components from human carotid plaques. Tissue strips of fibrous cap, media, lipid core and intraplaque hemorrhage/thrombus were obtained from 21 carotid endarterectomy samples of symptomatic patients. Uni-extension test with tissue strips was performed until they broke or slid. The Cauchy stress and stretch ratio at the peak loading of strips broken about 2 mm away from the clamp were used to characterize their ultimate strength and extensibility. Results obtained indicated that ultimate strength of fibrous cap and media were 158.3 [72.1, 259.3] kPa (Median [Inter quartile range]) and 247.6 [169.0, 419.9] kPa, respectively; those of lipid and intraplaque hemorrhage/thrombus were 68.8 [48.5, 86.6] kPa and 83.0 [52.1, 124.9] kPa, respectively. The extensibility of each tissue type were: fibrous cap – 1.18 [1.10, 1.27]; media – 1.21 [1.17, 1.32]; lipid – 1.25 [1.11, 1.30] and intraplaque hemorrhage/thrombus – 1.20 [1.17, 1.44]. Overall, the strength of fibrous cap and media were comparable and so were lipid and intraplaque hemorrhage/thrombus. Both fibrous cap and media were significantly stronger than either lipid or intraplaque hemorrhage/thrombus. All atherosclerotic components had similar extensibility. Moreover, fibrous cap strength in the proximal region (closer to the heart) was lower than that of the distal. These results are helpful in understanding the material behavior of atherosclerotic plaques.
Collapse
Affiliation(s)
- Zhongzhao Teng
- Department of Radiology, University of Cambridge, UK; Department of Engineering, University of Cambridge, UK.
| | - Jiaxuan Feng
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | - Yongxue Zhang
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | | | - Yuan Huang
- Department of Radiology, University of Cambridge, UK
| | - Adam J Brown
- Division of Cardiovascular Medicine, University of Cambridge, UK
| | - Zaiping Jing
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | - Qingsheng Lu
- Department of Vascular Surgery, Changhai Hospital, Shanghai, China
| | | |
Collapse
|
41
|
Yuan J, Teng Z, Feng J, Zhang Y, Brown AJ, Gillard JH, Jing Z, Lu Q. Influence of material property variability on the mechanical behaviour of carotid atherosclerotic plaques: a 3D fluid-structure interaction analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2015; 31:e02722. [PMID: 25940741 PMCID: PMC4528233 DOI: 10.1002/cnm.2722] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 03/10/2015] [Accepted: 04/27/2015] [Indexed: 06/04/2023]
Abstract
Mechanical analysis has been shown to be complementary to luminal stenosis in assessing atherosclerotic plaque vulnerability. However, patient-specific material properties are not available and the effect of material properties variability has not been fully quantified. Media and fibrous cap (FC) strips from carotid endarterectomy samples were classified into hard, intermediate and soft according to their incremental Young's modulus. Lipid and intraplaque haemorrhage/thrombus strips were classified as hard and soft. Idealised geometry-based 3D fluid-structure interaction analyses were performed to assess the impact of material property variability in predicting maximum principal stress (Stress-P1 ) and stretch (Stretch-P1 ). When FC was thick (1000 or 600 µm), Stress-P1 at the shoulder was insensitive to changes in material stiffness, whereas Stress-P1 at mid FC changed significantly. When FC was thin (200 or 65 µm), high stress concentrations shifted from the shoulder region to mid FC, and Stress-P1 became increasingly sensitive to changes in material properties, in particular at mid FC. Regardless of FC thickness, Stretch-P1 at these locations was sensitive to changes in material properties. Variability in tissue material properties influences both the location and overall stress/stretch value. This variability needs to be accounted for when interpreting the results of mechanical modelling.
Collapse
Affiliation(s)
- Jianmin Yuan
- Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Zhongzhao Teng
- Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, UK
- Department of Engineering, University of Cambridge, Cambridge, CB2 1PZ, UK
| | - Jiaxuan Feng
- Department of Vascular Surgery, Changhai Hospital, Changhai Road, Shanghai, 200433, China
| | - Yongxue Zhang
- Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, UK
- Department of Vascular Surgery, Changhai Hospital, Changhai Road, Shanghai, 200433, China
| | - Adam J Brown
- Division of Cardiovascular Medicine, University of Cambridge, Cambridge, CB2 1TN, UK
| | - Jonathan H Gillard
- Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Zaiping Jing
- Department of Vascular Surgery, Changhai Hospital, Changhai Road, Shanghai, 200433, China
| | - Qingsheng Lu
- Department of Vascular Surgery, Changhai Hospital, Changhai Road, Shanghai, 200433, China
| |
Collapse
|
42
|
Nieuwstadt HA, Fekkes S, Hansen HHG, de Korte CL, van der Lugt A, Wentzel JJ, van der Steen AFW, Gijsen FJH. Carotid plaque elasticity estimation using ultrasound elastography, MRI, and inverse FEA - A numerical feasibility study. Med Eng Phys 2015; 37:801-7. [PMID: 26130603 DOI: 10.1016/j.medengphy.2015.06.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 06/02/2015] [Accepted: 06/07/2015] [Indexed: 12/13/2022]
Abstract
The material properties of atherosclerotic plaques govern the biomechanical environment, which is associated with rupture-risk. We investigated the feasibility of noninvasively estimating carotid plaque component material properties through simulating ultrasound (US) elastography and in vivo magnetic resonance imaging (MRI), and solving the inverse problem with finite element analysis. 2D plaque models were derived from endarterectomy specimens of nine patients. Nonlinear neo-Hookean models (tissue elasticity C1) were assigned to fibrous intima, wall (i.e., media/adventitia), and lipid-rich necrotic core. Finite element analysis was used to simulate clinical cross-sectional US strain imaging. Computer-simulated, single-slice in vivo MR images were segmented by two MR readers. We investigated multiple scenarios for plaque model elasticity, and consistently found clear separations between estimated tissue elasticity values. The intima C1 (160 kPa scenario) was estimated as 125.8 ± 19.4 kPa (reader 1) and 128.9 ± 24.8 kPa (reader 2). The lipid-rich necrotic core C1 (5 kPa) was estimated as 5.6 ± 2.0 kPa (reader 1) and 8.5 ± 4.5 kPa (reader 2). A scenario with a stiffer wall yielded similar results, while realistic US strain noise and rotating the models had little influence, thus demonstrating robustness of the procedure. The promising findings of this computer-simulation study stimulate applying the proposed methodology in a clinical setting.
Collapse
Affiliation(s)
- H A Nieuwstadt
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands.
| | - S Fekkes
- Department of Radiology and Nuclear Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - H H G Hansen
- Department of Radiology and Nuclear Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - C L de Korte
- Department of Radiology and Nuclear Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - A van der Lugt
- Department of Radiology, Erasmus MC, Rotterdam, The Netherlands
| | - J J Wentzel
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
| | - A F W van der Steen
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands; Department of Imaging Science and Technology, Delft University of Technology, Delft, The Netherlands
| | - F J H Gijsen
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
43
|
Material properties of components in human carotid atherosclerotic plaques: a uniaxial extension study. Acta Biomater 2014; 10:5055-5063. [PMID: 25200842 PMCID: PMC4226324 DOI: 10.1016/j.actbio.2014.09.001] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Revised: 07/31/2014] [Accepted: 09/01/2014] [Indexed: 12/17/2022]
Abstract
Computational modelling to calculate the mechanical loading within atherosclerotic plaques has been shown to be complementary to defining anatomical plaque features in determining plaque vulnerability. However, its application has been partially impeded by the lack of comprehensive knowledge about the mechanical properties of various tissues within the plaque. Twenty-one human carotid plaques were collected from endarterectomy. The plaque was cut into rings, and different type of atherosclerotic tissues, including media, fibrous cap (FC), lipid and intraplaque haemorrhage/thrombus (IPH/T) was dissected for uniaxial extension testing. In total, 65 media strips from 17 samples, 59 FC strips from 14 samples, 38 lipid strips from 11 samples, and 21 IPH/T strips from 11 samples were tested successfully. A modified Mooney–Rivlin strain energy density function was used to characterize the stretch–stress relationship. The stiffnesses of media and FC are comparable, as are lipid and IPH/T. However, both media and FC are stiffer than either lipid or IPH/T. The median values of incremental Young’s modulus of media, FC, lipid and IPH/T at λ = 1 are 290.1, 244.5, 104.4, 52.9, respectively; they increase to 1019.5, 817.4, 220.7 and 176.9 at λ = 1.1; and 4302.7, 3335.0, 533.4 and 268.8 at λ = 1.15 (unit, kPa; λ, stretch ratio). The material constants of each tissue type are suggested to be: media, c1 = 0.138 kPa, D1 = 3.833 kPa and D2 = 18.803; FC, c1 = 0.186 kPa, D1 = 5.769 kPa and D2 = 18.219; lipid, c1 = 0.046 kPa, D1 = 4.885 kPa and D2 = 5.426; and IPH/T, c1 = 0.212 kPa, D1 = 4.260 kPa and D2 = 5.312. It is concluded that all soft atherosclerotic tissues are non-linear, and both media and FC are stiffer than either lipid or IPH/T.
Collapse
|
44
|
Modelling of Atherosclerotic Plaque for Use in a Computational Test-Bed for Stent Angioplasty. Ann Biomed Eng 2014; 42:2425-39. [DOI: 10.1007/s10439-014-1107-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 09/03/2014] [Indexed: 10/24/2022]
|
45
|
Lopata RGP, Peters MFJ, Nijs J, Oomens CWJ, Rutten MCM, van de Vosse FN. Vascular elastography: a validation study. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1882-1895. [PMID: 24798385 DOI: 10.1016/j.ultrasmedbio.2014.02.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/13/2014] [Accepted: 02/23/2014] [Indexed: 06/03/2023]
Abstract
Vascular elastography techniques are promising tools for mechanical characterization of diseased arteries. These techniques are usually validated with simulations or phantoms or by comparing results with histology or other imaging modalities. In the study described here, vascular elastography was applied to porcine aortas in vitro during inflation testing (n = 10) and results were compared with those of standard bi-axial tensile testing, a technique that directly measures the force applied to the tissue. A neo-Hookean model was fit to the stress-strain data, valid for large deformations. Results indicated good correspondence between the two techniques, with GUS = 110 ± 11 kPa and GTT = 108 ± 10 kPa for ultrasound and tensile testing, respectively. Bland-Altman analysis revealed little bias (GUS-GTT = 2 ± 20 kPa). The next step will be the application of a non-linear material model that is also adaptable for in vivo measurements.
Collapse
Affiliation(s)
- Richard G P Lopata
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Mathijs F J Peters
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Jan Nijs
- Department of Cardiac Surgery, University Hospital Brussels, Brussels, Belgium
| | - Cees W J Oomens
- Soft Tissue Biomechanics & Engineering, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
46
|
Karimi A, Navidbakhsh M, Shojaei A, Hassani K, Faghihi S. STUDY OF PLAQUE VULNERABILITY IN CORONARY ARTERY USING MOONEY–RIVLIN MODEL: A COMBINATION OF FINITE ELEMENT AND EXPERIMENTAL METHOD. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS 2014. [DOI: 10.4015/s1016237214500136] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Atherosclerosis is a disease in which plaque builds up inside arteries. It is also considered as one of the most serious and common forms of cardiovascular disease which can lead to heart attack and stroke. In the current research, finite element method is used to anticipate plaque vulnerability based on peak plaque stress using human samples. A total of 23 healthy and atherosclerotic human coronary arteries, including 14 healthy and 9 atherosclerotic are removed within 5 h postmortem. The samples are mounted on a uniaxial tensile test machine and the obtained mechanical properties are used in finite element models. The results, including the Mooney–Rivlin hyperelastic constants of the samples as well as peak plaque stresses, are computed. It is demonstrated that the atherosclerotic human coronary arteries have significantly (p < 0.05) higher stiffness compared to healthy ones. The hypocellular plaque, in addition, has the highest stress values compared to the cellular and calcified ones and, consequently, is so prone to rupture. The calcified plaque type, nevertheless, has the lowest stress values and, remains stable. The results of this study can be used in the plaque vulnerability prediction and could have clinical implications for interventions and surgeries, such as balloon angioplasty, bypass and stenting.
Collapse
Affiliation(s)
- Alireza Karimi
- Tissue Engineering and Biomaterials Division, National Institute of Genetic Engineering and Biotechnology, Tehran 14965/161, Iran
- Mechanical Engineering Department, Iran University of Science and Technology, Tehran 16844, Iran
| | - Mahdi Navidbakhsh
- Mechanical Engineering Department, Iran University of Science and Technology, Tehran 16844, Iran
| | - Ahmad Shojaei
- Research Department, Basir Eye Center, Tehran 14186, Iran
| | - Kamran Hassani
- Department of Biomechanics, Science and Research Branch, Islamic Azad University, Tehran 755/4515, Iran
| | - Shahab Faghihi
- Tissue Engineering and Biomaterials Division, National Institute of Genetic Engineering and Biotechnology, Tehran 14965/161, Iran
| |
Collapse
|
47
|
Akyildiz AC, Speelman L, Gijsen FJ. Mechanical properties of human atherosclerotic intima tissue. J Biomech 2014; 47:773-83. [DOI: 10.1016/j.jbiomech.2014.01.019] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 12/13/2022]
|
48
|
Towards mechanical characterization of intact endarterectomy samples of carotid arteries during inflation using Echo-CT. J Biomech 2014; 47:805-14. [DOI: 10.1016/j.jbiomech.2014.01.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 11/18/2022]
|
49
|
Compressive mechanical properties of atherosclerotic plaques—Indentation test to characterise the local anisotropic behaviour. J Biomech 2014; 47:784-92. [DOI: 10.1016/j.jbiomech.2014.01.018] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 11/20/2022]
|
50
|
Wan J, He F, Zhao Y, Zhang H, Zhou X, Wan M. Non-invasive vascular radial/circumferential strain imaging and wall shear rate estimation using video images of diagnostic ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:622-636. [PMID: 24361217 DOI: 10.1016/j.ultrasmedbio.2013.10.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 09/28/2013] [Accepted: 10/13/2013] [Indexed: 06/03/2023]
Abstract
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future.
Collapse
Affiliation(s)
- Jinjin Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Fangli He
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Yongfeng Zhao
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Hongmei Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Xiaodong Zhou
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.
| |
Collapse
|