1
|
Forsythe B, Berlinberg EJ, Khazi-Syed D, Patel HH, Forlenza EM, Okoroha KR, Williams BT, Yanke AB, Cole BJ, Verma NN. Greater Postoperative Biceps Tendon Migration Following Biceps Tenodesis Correlates with Lower Patient Reported Outcomes Scores. Arthroscopy 2024:S0749-8063(24)00570-X. [PMID: 39173686 DOI: 10.1016/j.arthro.2024.07.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 07/19/2024] [Accepted: 07/20/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE To assess the relationship between tendon migration, as measured by radiostereometric analysis (RSA), and patient-reported outcome measures (PROMs) following biceps tenodesis (BT); to determine the likelihood of achieving clinically significant outcomes (CSOs) following BT; and to identify factors that impact CSO achievement. METHODS Patients undergoing arthroscopic suprapectoral or open subpectoral BT at a single, high-volume academic medical center were prospectively enrolled. A tantalum bead sutured to the tenodesis construct was utilized as a radio-opaque marker. Biceps tendon migration was measured on calibrated radiographs at 12 weeks postoperatively. PROMs (Constant-Murley score [Constant], Single Assessment Numeric Evaluation [SANE], and Patient-Reported Outcomes Measurement Information Systemic-Upper Extremity [PROMIS-UE]) were collected preoperatively and at ≥2 years follow-up. RESULTS Of 115 patients enrolled, 94 (82%) patients were included (median age=52 years and BMI=31.4 kg/m2). At a mean follow-up of 2.9 years, median Constant, SANE, and PROMIS-UE were 33 (interquartile range [IQR]=26-35), 90 (IQR=80-99), and 47 (IQR=42-58), respectively. Median tantalum bead migration was 6.5 mm (IQR 1.8-13.8). There was a significant correlation between migration and Constant (r2 = 0.222, beta= -0.554, 95% CI -1.027- [-0.081], P=0.022), SANE (r2 = 0.238, beta= -0.198, 95% CI -0.337 - [-0.058], P=0.006) and PROMIS-UE (r2 = 0.233, beta= -0.406, 95% CI -0.707 - [-0.104], P=0.009). In univariable analysis, higher BMI was associated with achievement of substantial clinical benefit (SCB, unadj-OR=1.078, 95%CI 1.007-1.161, P=0.038). Greater bead migration was negatively associated with achievement of minimal clinically important difference (MCID, unadj-OR=0.969, 95% CI 0.943-0.993, P=0.014) and patient acceptable symptomatic state (PASS, unadj-OR 0.965, 95% CI 0.937-0.989, P=0.008) on all 3 instruments. CONCLUSION A 1 cm-increase in tenodesed biceps tendon migration was associated with a decrease in Constant, SANE, and PROMIS-UE of 6, 2, and 4 points, respectively, at a mean of 2.9 years after surgery. Most patients achieved clinically significant outcomes (CSOs) for these PROMs by latest follow-up, and greater biceps tendon construct migration was negatively associated with the likelihood of CSO achievement. LEVEL OF EVIDENCE IV, retrospective case series.
Collapse
Affiliation(s)
| | - Elyse J Berlinberg
- Midwest Orthopaedics at Rush, Chicago, IL, USA; Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Daanish Khazi-Syed
- Midwest Orthopaedics at Rush, Chicago, IL, USA; The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Harsh H Patel
- Midwest Orthopaedics at Rush, Chicago, IL, USA; St. Joseph's Health, Paterson, NJ, USA
| | | | | | | | | | | | | |
Collapse
|
2
|
Forsythe B, Patel HH, Berlinberg EJ, Forlenza EM, Okoroha KR, Williams BT, Yanke AB, Cole BJ, Verma NN. A Radiostereometric Analysis of Tendon Migration After Arthroscopic and Mini-Open Biceps Tenodesis: Interference Screw Versus Single Suture Anchor Fixation. Am J Sports Med 2023; 51:2869-2880. [PMID: 37548005 DOI: 10.1177/03635465231187030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
BACKGROUND Studies suggest that similar clinical results are achieved via arthroscopic and open biceps tenodesis (BT) techniques. PURPOSE To quantify the postoperative migration of the BT construct between arthroscopic suprapectoral BT (ASPBT) and open subpectoral BT (OSPBT) techniques via interference screw (IS) or single-suture suture anchor (SSSA) fixation using radiostereometric analysis. STUDY DESIGN Cohort study; Level of evidence, 2. METHODS Distal migration of the biceps tendon after OSPBT with a polyetheretherketone IS, OSPBT with 1 SSSA, ASPBT with polyetheretherketone IS, and ASPBT with 2 SSSAs was measured prospectively. Patients with symptomatic biceps tendinopathy and preoperative patient-reported outcome measures (PROMs) including Constant-Murley subjective, Single Assessment Numeric Evaluation, or Patient-Reported Outcomes Measurement Information System-Upper Extremity scores were included. A tantalum bead was sutured on the proximal end of the long head of the biceps tendon before fixation of tendon tissue. Anteroposterior radiographs were performed immediately postoperatively, at 1 week, and at 3 months. Bead migration was measured, and preoperative PROMs were compared with those at latest follow-up. RESULTS Of 115 patients, 94 (82%) were available for final follow-up. IS fixation yielded the least tendon migration with no difference between the open and arthroscopic approaches (4.31 vs 5.04 mm; P = .70). Fixation with 1 suture anchor demonstrated significantly greater migration than that achieved with an IS at both 1 week (6.47 vs 0.1 mm, 6.47 vs 1.75 mm, P < .001;) and 3 months (14.76 vs 4.31 mm, 14.76 vs 5.04 mm, P < .001) postoperatively. Two-suture anchor fixation yielded significantly greater migration than IS fixation at 1 week (7.02 vs 0.1 mm, P < .001; 7.02 vs 1.75 mm, P = .003) but not 3 months postoperatively (8.06 vs 4.31 mm, P = .10; 8.06 vs 5.04 mm, P = .07). Four patients with suture anchor fixation (3 patients in the OSPBT 1 SSSA group, 9.4%, and 1 patient in the ASPBT 2 SSSAs group, 3.8%) developed a Popeye deformity, whereas no Popeye deformities occurred in the IS groups. Mean 3-month bead migration in patients with and without a Popeye deformity was 60.8 and 11.2 mm, respectively (P < .0001). PROMs did not differ among groups at final follow-up. CONCLUSION Interference screw fixation yielded the least tendon migration whether achieved arthroscopically or open. The available data indicated that fixation with 1 SSSA but not 2 SSSAs resulted in significantly greater migration than that achieved with an IS. Despite variations in tendon migration, PROMs were similar among all groups. When SSSAs are used, tendon migration may be minimized by using ≥2 anchors.
Collapse
Affiliation(s)
| | - Harsh H Patel
- Midwest Orthopaedics at Rush, Chicago, Illinois, USA
| | | | | | - Kelechi R Okoroha
- Mayo Clinic Orthopedics and Sports Medicine, Minneapolis, Minnesota, USA
| | - Brady T Williams
- University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Adam B Yanke
- Midwest Orthopaedics at Rush, Chicago, Illinois, USA
| | - Brian J Cole
- Midwest Orthopaedics at Rush, Chicago, Illinois, USA
| | | |
Collapse
|
3
|
Lawrence RL, Ruder MC, Zauel R, Jalics A, Olszewski AM, Diefenbach BJ, Moutzouros V, Makhni EC, Muh S, Bey MJ. In Vivo Static Retraction and Dynamic Elongation of Rotator Cuff Repair Tissue After Surgical Repair: A Preliminary Analysis at 3 Months. Orthop J Sports Med 2022; 10:23259671221084294. [PMID: 35387360 PMCID: PMC8978322 DOI: 10.1177/23259671221084294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 12/23/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon’s insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.
Collapse
Affiliation(s)
| | - Matthew C Ruder
- Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | - Roger Zauel
- Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | - Alena Jalics
- Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | - Adam M Olszewski
- Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | | | - Vasilios Moutzouros
- Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Eric C Makhni
- Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Stephanie Muh
- Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Michael J Bey
- Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| |
Collapse
|
4
|
Variability of glenohumeral positioning and bone-to-tendon marker length measurements in repaired rotator cuffs from longitudinal computed tomographic imaging. JSES Int 2020; 4:838-847. [PMID: 33345224 PMCID: PMC7738576 DOI: 10.1016/j.jseint.2020.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Background To address the need for more objective and quantitative measures of tendon healing in research studies, we intend to use computed tomography (CT) with implanted radiopaque markers on the repaired tendon to measure tendon retraction following rotator cuff repair. In our small prior study, retraction at 1-year follow-up averaged 16.1± 5.3 mm and exceeded 10.0 mm in 12 of 13 patients, and thus tendon retraction appears to be a common clinical phenomenon. This study's objectives were to assess, using 5 longitudinal CT scans obtained over 1 year following rotator cuff repair, the variability in glenohumeral positioning because of pragmatic variations in achieving perfect arm repositioning and to estimate the associated measurement variability in bone-to-tendon marker length measurements. Methods Forty-eight patients underwent rotator cuff repair with intraoperative placement of radiopaque tendon markers at the repair site. All patients had a CT scan with their arms at the side on the day of surgery and at 3, 12, 26, and 52 weeks postoperatively. Glenohumeral position (defined by the orientation and distance of the humerus with respect to the scapula) and bone-to-tendon marker lengths were measured from each scan. Within-patient variation in glenohumeral position measurements was described by their pooled within-patient standard deviations (SDs), and variation in bone-to-tendon marker lengths by their standard errors of measurement (SEMs) and 95% confidence level minimally detectable distances (MDD95) and changes (MDC95). Results The mean glenohumeral orientation from the 5 longitudinal CT scans averaged across the 48 patients was 12.6° abduction, 0.4° flexion, and –0.1° internal rotation. Within-patient SDs (95% confidence intervals) of glenohumeral orientation were 3.0° (2.7°-3.4°) in extension/flexion, 5.2° (4.6°-5.8°) in abduction/adduction, and 8.2° (7.3°-9.2°) in internal/external rotation. The SDs of glenohumeral distances were less than 1 mm in any direction. The estimated SEMs of bone-to-tendon lengths were consistent with a common value of 2.4 mm for any of the tendon markers placed across the repair, with MDD95 of 4.7 mm and MDC95 of 6.7 mm. Conclusion Apparent tendon retraction of 5 mm or more, when measured as the distance from a tendon marker's day of surgery location to its new location on a volumetrically registered longitudinal CT scan, may be considered above the usual range of measurement variation. Tendon retraction measured using implanted radiopaque tendon markers offers an objective and sufficiently reliable means for quantifying the commonly expected changes in structural healing following rotator cuff repair.
Collapse
|
5
|
Okoroha KR, Ussef N, Jildeh TR, Khalil LS, Hasan L, Bench C, Zeni F, Eller E, Moutzouros V. Comparison of Tendon Lengthening With Traditional Versus Accelerated Rehabilitation After Achilles Tendon Repair: A Prospective Randomized Controlled Trial. Am J Sports Med 2020; 48:1720-1726. [PMID: 32203675 DOI: 10.1177/0363546520909389] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Early weightbearing protocols after Achilles tendon repair promote mobilization, yet little is known about their effect on tendon lengthening. PURPOSE To evaluate tendon lengthening after Achilles tendon repair with accelerated rehabilitation. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS Patients undergoing primary repair for acute Achilles tendon ruptures consented to have tantalum beads placed within the tendon. Patients were randomized into either a traditional (weightbearing at 6 weeks) or accelerated (graduated weightbearing at 2 weeks) rehabilitation group. The primary outcome of the study was postoperative tendon elongation as measured by radiostereometric beads. Secondary outcomes included Achilles Tendon Total Rupture Score (ATRS) and Patient-Reported Outcomes Measurement Information System Pain Interference Short Form (PROMIS PI-SF) score. RESULTS All 18 patients included in the final analysis were found to have significant tendon lengthening after surgery, with a mean lengthening of 15.9 mm. No significant differences were found in overall lengthening between the traditional and accelerated rehabilitation groups (15.3 ± 4.5 vs 16.4 ± 4.7 mm, respectively; P = .33) at final follow-up. The repair site in each group was found to lengthen more than the intratendinous site (traditional group, 13.2 vs 2.1 mm; accelerated group, 16.8 vs -0.4 mm); however, no difference in lengthening was seen between groups (P = .82 and P = .31, respectively). The greatest amount of lengthening occurred between 2 and 6 weeks, and the least amount of lengthening occurred between 6 and 12 weeks, with no difference between the traditional and accelerated groups at these time points (P = .84 and P = .38, respectively). No differences were noted in ankle range of motion (dorsiflexion, P = .16; plantarflexion, P = .08) or outcome scores (ATRS, P = .56; PROMIS PI-SF, P = .54). CONCLUSION This study's findings demonstrate that all patients undergoing operative repair of Achilles tendon ruptures had lengthening after surgery. No difference was found in tendon lengthening (repair site or intratendinous) at any time point between patients undergoing traditional versus accelerated rehabilitation postoperatively. The greatest amount of lengthening was found to occur between 2 and 6 weeks postoperatively, and tendon lengthening decreased significantly after 6 weeks. REGISTRATION NCT04050748 (ClinicalTrials.gov identifier).
Collapse
Affiliation(s)
- Kelechi R Okoroha
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Najib Ussef
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Toufic R Jildeh
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Lafi S Khalil
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Laith Hasan
- Tulane University Medical School, New Orleans, Louisiana, USA
| | - Carter Bench
- Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Ferras Zeni
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Erik Eller
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| | - Vasilios Moutzouros
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan, USA
| |
Collapse
|
6
|
Sahoo S, Baker AR, Jun BJ, Erdemir A, Ricchetti ET, Iannotti JP, Derwin KA. A novel radiopaque tissue marker for soft tissue localization and in vivo length and area measurements. PLoS One 2019; 14:e0224244. [PMID: 31626672 PMCID: PMC6799909 DOI: 10.1371/journal.pone.0224244] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Accepted: 10/08/2019] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The purpose of the study was to describe the characteristics and demonstrate proof-of-concept and clinical use of a barium sulfate infused polypropylene radiopaque tissue marker for soft tissue localization and in vivo measurement of lengths and areas. METHODS Marker mechanical properties were evaluated by tensile tests. Biocompatibility was evaluated following 8-12 weeks' implantation in a pig model. Proof-of-concept of marker application was performed in a human cadaveric shoulder model, and methods for CT imaging and measurement of dimensions were established. Lastly, the method of clinical use of the markers was described in one patient undergoing arthroscopic rotator cuff repair (RCR). RESULTS The radiopaque markers had a tensile strength of 28 ±4.7 N and were associated with minimal to mild inflammatory tissue reaction similar to polypropylene control. CT-based measurements showed relatively high precisions for lengths (0.66 mm), areas (6.97 mm2), and humeral orientation angles (2.1°) in the cadaveric model, and demonstrated 19 ±3 mm medio-lateral tendon retraction and 227 ±3 mm2 increase in tendon area in the patient during 26 weeks following RCR. No radiographic leaching, calcification or local adverse events were observed. CONCLUSIONS The radiopaque tissue marker was biocompatible and had adequate strength for handling and affixation to soft tissues using standard suturing techniques. The marker could be used with low-dose, sequential CT imaging to quantitatively measure rotator cuff tendon retractions with clinically acceptable accuracy. We envision the radiopaque tissue marker to be useful for soft tissue localization and in vivo measurement of tissue and organ dimensions following surgery.
Collapse
Affiliation(s)
- Sambit Sahoo
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
- Department of Orthopaedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Andrew R. Baker
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Bong Jae Jun
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
- Department of Orthopaedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Ahmet Erdemir
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Eric T. Ricchetti
- Department of Orthopaedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Joseph P. Iannotti
- Department of Orthopaedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| | - Kathleen A. Derwin
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
- Department of Orthopaedic Surgery, Orthopedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio, United States of America
| |
Collapse
|
7
|
Abdellatif AA, Abou-Taleb HA, Abd El Ghany AA, Lutz I, Bouazzaoui A. Targeting of somatostatin receptors expressed in blood cells using quantum dots coated with vapreotide. Saudi Pharm J 2018; 26:1162-1169. [PMID: 30532637 PMCID: PMC6260484 DOI: 10.1016/j.jsps.2018.07.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2018] [Accepted: 07/19/2018] [Indexed: 12/27/2022] Open
Abstract
Cancer may be difficult to target, however, if cancer targeted this provides the chance for a better and more effective treatment. Quantum dots (Qdots) coated vapreotide (VAP) as a somatostatin receptors (SSTRs) agonist can be efficient targeting issue since may reduce side effects and increase drug delivery to the target tissue. This study highlights the active targeting of cancer cells by cells imaging with improving the therapeutic outcomes. VAP was conjugated to Qdots using amine-to-sulfhydryl crosslinker. The synthesized Qdots-VAP was characterized by determination of size, measuring the zeta-potential and UV fluorometer. The cellular uptake was studied using different cell lines. Finally, the Qdots-VAP was injected into a rat model. The results showed a size of 479.8 ± 15 and 604.88 ± 17 nm for unmodified Qdots and Qdots-VAP respectively, while the zeta potential of particles went from negative to positive charge which proved the conjugation of VAP to Qdots. The fluorometer recorded a redshift for Qdots-VAP compared with unmodified Qdots. Moreover, cellular uptake exhibited high specific binding with cells which express SSTRs using confocal microscopy and flow cytometry (17.3 MFU comparing to 3.1 MFU of control, P < 0.001). Finally, an in vivo study showed a strong accumulation of Qdots-VAP in the blood cells (70%). In conclusion, Qdots-VAP can play a crucial role in cancer diagnosis and treatment of blood cells diseases when conjugated with VAP as SSTRs agonist.
Collapse
Affiliation(s)
- Ahmed A.H. Abdellatif
- Pharmaceutics and Industrial Pharmacy Department, Faculty of Pharmacy, Al-Azhar University, 71524 Assiut, Egypt
- Pharmaceutics Department, Faculty of Pharmacy, Qassim University, 51452 Buraydah, Saudi Arabia
| | - Heba A. Abou-Taleb
- Pharmaceutics and Industrial Pharmacy Department, Faculty of Pharmacy, Nahda University (NUB), Benisuef, Egypt
| | | | - Ilka Lutz
- Leibniz-Institute of Freshwater Ecology and Inland Fisheries, Mueggelseedamm 301, 12587 Berlin, Germany
| | - Abdellatif Bouazzaoui
- Science and Technology Unit, Umm Al Qura University, Makkah 21955, Saudi Arabia
- Internal Medicine 3-Hematology/Oncology Department, University Medical Center, Regensburg, Germany
| |
Collapse
|
8
|
Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties. BIOMED RESEARCH INTERNATIONAL 2017; 2017:3681458. [PMID: 28243598 PMCID: PMC5294349 DOI: 10.1155/2017/3681458] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2016] [Revised: 11/18/2016] [Accepted: 12/12/2016] [Indexed: 02/03/2023]
Abstract
As part of the 14-year follow-up of a prospectively randomized radiostereometry (RSA) study on uncemented cup fixation, two pairs of stereo radiographs and a CT scan of 46 hips were compared. Tantalum beads, inserted during the primary operation, were detected in the CT volume and the stereo radiographs and used to produce datasets of 3D coordinates. The limit of agreement between the combined CT and RSA datasets was calculated in the same way as the precision of the double RSA examination. The precision of RSA corresponding to the 99% confidence interval was 1.36°, 1.36°, and 0.60° for X-, Y-, and Z-rotation and 0.40, 0.17, and 0.37 mm for X-, Y-, and Z-translation. The limit of agreement between CT and RSA was 1.51°, 2.17°, and 1.05° for rotation and 0.59, 0.56, and 0.74 mm for translation. The differences between CT and RSA are close to the described normal 99% confidence interval for precision in RSA: 0.3° to 2° for rotation and 0.15 to 0.6 mm for translation. We conclude that measurements using CT and RSA are comparable and that CT can be used for migration studies for longitudinal evaluations of patients with RSA markers.
Collapse
|
9
|
Marshall NE, Keller RA, Okoroha K, Guest JM, Yu C, Muh S, Moutzouros V. Radiostereometric Evaluation of Tendon Elongation After Distal Biceps Repair. Orthop J Sports Med 2016; 4:2325967116672620. [PMID: 27928546 PMCID: PMC5131736 DOI: 10.1177/2325967116672620] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND Operative repair of distal biceps tendon ruptures has shown successful outcomes. However, little is known about the amount of tendon or repair site lengthening after repair. PURPOSE/HYPOTHESIS The purpose of this study was to evaluate distal biceps tendon repair via intratendinous radiostereometric analysis to analyze tendon lengthening at different time intervals of healing. The hypothesis was that there is significant lengthening after repair. STUDY DESIGN Case series; Level of evidence, 4. METHODS Eleven patients with distal biceps ruptures requiring operative repair were recruited. During repair, two 2-mm tantalum beads with laser-etched holes were sutured to the distal biceps tendon. Beads were evaluated via computed tomography scans immediately postoperatively and at 16 weeks. Radiographs were obtained at time 0 and then at 4, 8, and 16 weeks postoperatively. Measurements were made using the button-to-bead and bead-to-bead distances to assess repair site elongation as well as tendon elongation over time. After final follow-up, patients filled out the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and underwent ultrasound to confirm the integrity of the tendon. RESULTS Ten patients had complete ruptures, with 1 having a partial rupture that underwent completion of the tear and subsequent repair. All patients showed statistically significant lengthening after surgery. The mean amount of tendon lengthening after surgery was 22.8 mm (range, 11.2-30.9 mm; P < .05), and the repair site lengthened a mean 17.0 mm (range, 9.6-30.6 mm; P < .05) from surgery to final follow-up. The greatest change in lengthening was noted between time 0 and week 4 (mean, 11.3 mm; P < .05), with the least amount of lengthening between weeks 8 and 16 (mean, 2.6 mm; P < .05). The mean DASH score was 11.2. Final ultrasound evaluations found all tendons to be in continuity. CONCLUSION All patients undergoing distal biceps tendon repair have significant elongation after surgery, with the greatest amount of lengthening seen in the early postoperative period.
Collapse
Affiliation(s)
- Nathan E Marshall
- Orthopedic Surgery Department, Henry Ford Hospital, Detroit, Michigan, USA
| | - Robert A Keller
- Orthopedic Surgery Department, Henry Ford Hospital, Detroit, Michigan, USA
| | - Kelechi Okoroha
- Orthopedic Surgery Department, Henry Ford Hospital, Detroit, Michigan, USA
| | | | - Charles Yu
- Orthopedic Surgery Department, Henry Ford Hospital, Detroit, Michigan, USA
| | - Stephanie Muh
- Orthopedic Surgery Department, Henry Ford Hospital, Detroit, Michigan, USA
| | | |
Collapse
|
10
|
Olivecrona H, Maguire GQ, Noz ME, Zeleznik MP, Kesteris U, Weidenhielm L. A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients. J Orthop Surg Res 2016; 11:27. [PMID: 26911571 PMCID: PMC4766687 DOI: 10.1186/s13018-016-0360-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Accepted: 02/17/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Radiostereometric analysis (RSA) is often used for evaluating implanted devices over time. Following patients who have had tantalum beads implanted as markers in conjunction with joint replacements is important for longitudinal evaluation of these patients and for those with similar implants. As doing traditional RSA imaging is exacting and limited to specialized centers, it is important to consider alternative techniques for this ongoing evaluation. This paper studies the use of computed tomography (CT) to evaluate over time tantalum beads which have been implanted as markers. METHODS The project uses both a hip model implanted with tantalum beads, acquired in several orientations, at two different CT energy levels, and a cohort of seven patients. The model was evaluated twice by the same observer with a 1-week interval. All CT volumes were analyzed using a semi-automated 3D volume fusion (spatial registration) tool which provides landmark-based fusion of two volumes, registering a target volume with a reference volume using a rigid body 3D algorithm. The mean registration errors as well as the accuracy and repeatability of the method were evaluated. RESULTS The mean registration error, maximum value of repeatability, and accuracy for the relative movement in the model were 0.16 mm, 0.02° and 0.1 mm, and 0.36° and 0.13 mm for 120 kVp and 0.21 mm, 0.04° and 0.01 mm, and 0.39° and 0.12 mm for 100 kVp. For the patients, the mean registration errors per patient ranged from 0.08 to 0.35 mm. These results are comparable to those in typical clinical RSA trials. This technique successfully evaluated two patients who would have been lost from the cohort if only RSA were used. CONCLUSIONS The proposed technique can be used to evaluate patients with tantalum beads over time without the need for stereoradiographs. Further, the effective dose associated with CT is decreasing.
Collapse
Affiliation(s)
- Henrik Olivecrona
- Department of Molecular Medicine and Surgery, Karolinska Institutet, SE-17176, Stockholm, Sweden.
| | - Gerald Q Maguire
- School of Information and Communication Technology, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Marilyn E Noz
- Department of Radiology, New York University School of Medicine, 560 First Avenue, New York, NY, 10016, USA.
| | - Michael P Zeleznik
- School of Computing, College of Engineering, University of Utah, Salt Lake City, UT, USA.
| | - Uldis Kesteris
- Department of Orthopedics, Skåne University Hospital, Lund, Sweden.
| | - Lars Weidenhielm
- Department of Molecular Medicine and Surgery, Karolinska Institutet, SE-17176, Stockholm, Sweden.
| |
Collapse
|
11
|
McCarron JA, Derwin KA, Bey MJ, Polster JM, Schils JP, Ricchetti ET, Iannotti JP. Failure with continuity in rotator cuff repair "healing". Am J Sports Med 2013; 41:134-41. [PMID: 23019253 DOI: 10.1177/0363546512459477] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Ten to seventy percent of rotator cuff repairs form a recurrent defect after surgery. The relationship between retraction of the repaired tendon and formation of a recurrent defect is not well defined. PURPOSE/ HYPOTHESES: To measure the prevalence, timing, and magnitude of tendon retraction after rotator cuff repair and correlate these outcomes with formation of a full-thickness recurrent tendon defect on magnetic resonance imaging, as well as clinical outcomes. We hypothesized that (1) tendon retraction is a common phenomenon, although not always associated with a recurrent defect; (2) formation of a recurrent tendon defect correlates with the timing of tendon retraction; and (3) clinical outcome correlates with the magnitude of tendon retraction at 52 weeks and the formation of a recurrent tendon defect. STUDY DESIGN Case series; Level of evidence, 4. METHODS Fourteen patients underwent arthroscopic rotator cuff repair. Tantalum markers placed within the repaired tendons were used to assess tendon retraction by computed tomography scan at 6, 12, 26, and 52 weeks after operation. Magnetic resonance imaging was performed to assess for recurrent tendon defects. Shoulder function was evaluated using the Penn score, visual analog scale (VAS) score for pain, and isometric scapular-plane abduction strength. RESULTS All rotator cuff repairs retracted away from their position of initial fixation during the first year after surgery (mean [standard deviation], 16.1 [5.3] mm; range, 5.7-23.2 mm), yet only 30% of patients formed a recurrent defect. Patients who formed a recurrent defect tended to have more tendon retraction during the first 6 weeks after surgery (9.7 [6.0] mm) than those who did not form a defect (4.1 [2.2] mm) (P = .08), but the total magnitude of tendon retraction was not significantly different between patient groups at 52 weeks. There was no significant correlation between the magnitude of tendon retraction and the Penn score (r = 0.01, P = .97) or normalized scapular abduction strength (r = -0.21, P = .58). However, patients who formed a recurrent defect tended to have lower Penn scores at 52 weeks (P = .1). CONCLUSION Early tendon retraction, but not the total magnitude, correlates with formation of a recurrent tendon defect and worse clinical outcomes. "Failure with continuity" (tendon retraction without a recurrent defect) appears to be a common phenomenon after rotator cuff repair. These data suggest that repairs should be protected in the early postoperative period and repair strategies should endeavor to mechanically and biologically augment the repair during this critical early period.
Collapse
Affiliation(s)
- Jesse A McCarron
- Department of Orthopaedic Surgery, Cleveland Clinic, Ohio 44195, USA
| | | | | | | | | | | | | |
Collapse
|