1
|
Mutlu O, Saribay M, Yavuz MM, Salman HE, Al-Nabti ARDMH, Yalcin HC. Material modeling and recent findings in transcatheter aortic valve implantation simulations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 255:108314. [PMID: 39024970 DOI: 10.1016/j.cmpb.2024.108314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/12/2024] [Accepted: 06/28/2024] [Indexed: 07/20/2024]
Abstract
BACKGROUND AND OBJECTIVE Transcatheter aortic valve implantation (TAVI) has significantly transformed the management of aortic valve (AV) diseases, presenting a minimally invasive option compared to traditional surgical valve replacement. Computational simulations of TAVI become more popular and offer a detailed investigation by employing patient-specific models. On the other hand, employing accurate material modeling procedures and applying basic modeling steps are crucial to determining reliable numerical results. Therefore, this review aims to outline the basic modeling approaches for TAVI, focusing on material modeling and geometry extraction, as well as summarizing the important findings from recent computational studies to guide future research in the field. METHODS This paper explains the basic steps and important points in setting up and running TAVI simulations. The material properties of the leaflets, valves, stents, and tissues utilized in TAVI simulations are provided, along with a comprehensive explanation of the geometric extraction methods employed. The differences between the finite element analysis, computational fluid dynamics, and fluid-structure interaction approaches are pointed out and the important aspects of TAVI modeling are described by elucidating the recent computational studies. RESULTS The results of the recent findings on TAVI simulations are summarized to demonstrate its powerful potential. It is observed that the material properties of aortic tissues and components of implanted valves should be modeled realistically to determine accurate results. For patient-specific AV geometries, incorporating calcific deposits on the leaflets is essential for ensuring the accuracy of computational findings. The results of numerical TAVI simulations indicate the significance of the selection of optimal valves and precise deployment within the appropriate anatomical position. These factors collectively contribute to the effective functionality of the implanted valve. CONCLUSIONS Recent studies in the literature have revealed the critical importance of patient-specific modeling, the selection of accurate material models, and bio-prosthetic valve diameters. Additionally, these studies emphasize the necessity of precise positioning of bio-prosthetic valves to achieve optimal performance in TAVI, characterized by an increased effective orifice area and minimal paravalvular leakage.
Collapse
Affiliation(s)
- Onur Mutlu
- Qatar University, Biomedical Research Center, Doha, Qatar
| | - Murat Saribay
- Istanbul Bilgi University, Mechanical Engineering Department, Istanbul, Turkey
| | - Mehmet Metin Yavuz
- Middle East Technical University, Mechanical Engineering Department, Ankara, Turkey
| | - Huseyin Enes Salman
- TOBB University of Economics and Technology, Department of Mechanical Engineering, Ankara, Turkey
| | | | - Huseyin Cagatay Yalcin
- Qatar University, Biomedical Research Center, Doha, Qatar; Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar.
| |
Collapse
|
2
|
Tac V, Kuhl E, Tepole AB. Data-driven continuum damage mechanics with built-in physics. EXTREME MECHANICS LETTERS 2024; 71:102220. [PMID: 39372561 PMCID: PMC11449040 DOI: 10.1016/j.eml.2024.102220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/08/2024]
Abstract
Soft materials such as rubbers and soft tissues often undergo large deformations and experience damage degradation that impairs their function. This energy dissipation mechanism can be described in a thermodynamically consistent framework known as continuum damage mechanics. Recently, data-driven methods have been developed to capture complex material behaviors with unmatched accuracy due to the high flexibility of deep learning architectures. Initial efforts focused on hyperelastic materials, and recent advances now offer the ability to satisfy physics constraints such as polyconvexity of the strain energy density function by default. However, modeling inelastic behavior with deep learning architectures and built-in physics has remained challenging. Here we show that neural ordinary differential equations (NODEs), which we used previously to model arbitrary hyperelastic materials with automatic polyconvexity, can be extended to model energy dissipation in a thermodynamically consistent way by introducing an inelastic potential: a monotonic yield function. We demonstrate the inherent flexibility of our network architecture in terms of different damage models proposed in the literature. Our results suggest that our NODEs re-discover the true damage function from synthetic stress-deformation history data. In addition, they can accurately characterize experimental skin and subcutaneous tissue data.
Collapse
Affiliation(s)
- Vahidullah Tac
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Ellen Kuhl
- Department of Mechanical Engineering, Stanford University, Stanford, California, USA
| | - Adrian Buganza Tepole
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
3
|
Pak DH, Liu M, Kim T, Ozturk C, McKay R, Roche ET, Gleason R, Duncan JS. Robust automated calcification meshing for personalized cardiovascular biomechanics. NPJ Digit Med 2024; 7:213. [PMID: 39143242 PMCID: PMC11324740 DOI: 10.1038/s41746-024-01202-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 07/26/2024] [Indexed: 08/16/2024] Open
Abstract
Calcification has significant influence over cardiovascular diseases and interventions. Detailed characterization of calcification is thus desired for predictive modeling, but calcium deposits on cardiovascular structures are still often manually reconstructed for physics-driven simulations. This poses a major bottleneck for large-scale adoption of computational simulations for research or clinical use. To address this, we propose an end-to-end automated image-to-mesh algorithm that enables robust incorporation of patient-specific calcification onto a given cardiovascular tissue mesh. The algorithm provides a substantial speed-up from several hours of manual meshing to ~1 min of automated computation, and it solves an important problem that cannot be addressed with recent template-based meshing techniques. We validated our final calcified tissue meshes with extensive simulations, demonstrating our ability to accurately model patient-specific aortic stenosis and Transcatheter Aortic Valve Replacement. Our method may serve as an important tool for accelerating the development and usage of personalized cardiovascular biomechanics.
Collapse
Affiliation(s)
- Daniel H Pak
- Yale University, 300 Cedar St, New Haven, CT, 06511, USA.
| | - Minliang Liu
- Texas Tech University, 805 Boston Avenue, Lubbock, TX, 79409, USA
| | - Theodore Kim
- Yale University, 300 Cedar St, New Haven, CT, 06511, USA
| | - Caglar Ozturk
- Massachusetts Institute of Technology, 45 Carleton St, Cambridge, MA, 02142, USA
- University of Southampton, University Road, Southampton, SO17 1BJ, UK
| | - Raymond McKay
- Hartford Hospital, 85 Seymour St, Hartford, CT, 06106, USA
| | - Ellen T Roche
- Massachusetts Institute of Technology, 45 Carleton St, Cambridge, MA, 02142, USA
| | - Rudolph Gleason
- Georgia Institute of Technology, 315 Ferst Dr NW, Atlanta, GA, 30332, USA
| | - James S Duncan
- Yale University, 300 Cedar St, New Haven, CT, 06511, USA
| |
Collapse
|
4
|
Noble C, Hooke A, Rajotia A, Morse D, Dragomir-Daescu D, Salisbury J, Young MD, Lerman A. Effect of mechanical fatigue on commercial bioprosthetic TAVR valve mechanical and microstructural properties. J Mech Behav Biomed Mater 2024; 154:106441. [PMID: 38518510 DOI: 10.1016/j.jmbbm.2024.106441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 01/15/2024] [Accepted: 01/27/2024] [Indexed: 03/24/2024]
Abstract
Valvular structural deterioration is of particular concern for transcatheter aortic valve replacements due to their suspected shorter longevity and increasing use in younger patient populations. In this work we investigated the mechanical and microstructural changes in commercial TAVR valves composed of both glutaraldehyde fixed bovine and porcine pericardium (GLBP and GLPP) following accelerated wear testing (AWT) as outlined in ISO 5840 standards. This provided greater physiological relevance to the loading compared to previous studies and by utilizing digital image correlation we were able to obtain strain contours for each leaflet pre and post fatigue and identify sites of fatigue damage. The areas of greatest change in mechanical strain for each leaflet were then further probed using biaxial tensile testing, confocal microscopy, and electron microscopy. It was observed that overall strain decreased in the GLPP valves following AWT of 200 million cycles while the GLBP valve showed an increase in overall strain. Biaxial tensile testing showed a statistically significant reduction in stress for GLPP while no significant changes were seen for GLBP. Both confocal and electron microscopy showed a disruption to the gross collagen organization and fibrillar structure, including fragmentation, for GLPP but only the former for GLBP. However, further test data is required to confirm these findings and to provide a better understanding of this fatigue pathway is required such that it can be incorporated into both valve design and selection processes to improve overall longevity for both GLPP and GLBP devices.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
| | | | - Arush Rajotia
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - David Morse
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Dan Dragomir-Daescu
- Department of Biomedical Engineering and Physiology, Mayo Clinic, Rochester, MN, USA
| | - Jeffery Salisbury
- Department of Biochemistry and Molecular Biology, Mayo Clinic, Rochester, MN, USA
| | - Melissa D Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
5
|
Oks D, Houzeaux G, Vázquez M, Neidlin M, Samaniego C. Effect of TAVR commissural alignment on coronary flow: A fluid-structure interaction analysis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 242:107818. [PMID: 37837886 DOI: 10.1016/j.cmpb.2023.107818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 09/07/2023] [Accepted: 09/15/2023] [Indexed: 10/16/2023]
Abstract
BACKGROUND AND OBJECTIVES Coronary obstruction is a complication that may affect patients receiving Transcatheter Aortic Valve Replacement (TAVR), with catastrophic consequences and long-term negative effects. To enable healthy coronary perfusion, it is fundamental to appropriately position the device with respect to the coronary ostia. Nonetheless, most TAVR delivery systems do not control commissural alignment to do so. Moreover, no in silico study has directly assessed the effect of commissural alignment on coronary perfusion. This work aims to evaluate the effect of TAVR commissural alignment on coronary perfusion and device performance. METHODS A two-way computational fluid-structure interaction model is used to predict coronary perfusion at different commissural alignments. Moreover, in each scenario, hemodynamic biomarkers are evaluated to assess device performance. RESULTS Commissural misalignment is shown to reduce the total coronary perfusion by -3.2% and the flow rate to a single coronary branch by -6.8%. It is also observed to impair valvular function by reducing the systolic geometric orifice area by -2.5% and increasing the systolic transvalvular pressure gradients by +5.3% and the diastolic leaflet stresses by +16.0%. CONCLUSIONS The present TAVR patient model indicates that coronary perfusion, hemodynamic and structural performance are minimized when the prosthesis commissures are fully misaligned with the native ones. These results support the importance of enabling axial control in new TAVR delivery catheter systems and defining recommended values of commissural alignment in upcoming clinical treatment guidelines.
Collapse
Affiliation(s)
- David Oks
- Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Plaça d'Eusebi Güell, 1-3, 08034, Barcelona, Spain; ELEM Biotech SL, Plaça Pau Vila, 1, Bloc A, Planta 3, Porta 3A1, 08003, Barcelona, Spain.
| | - Guillaume Houzeaux
- Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Plaça d'Eusebi Güell, 1-3, 08034, Barcelona, Spain
| | - Mariano Vázquez
- Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Plaça d'Eusebi Güell, 1-3, 08034, Barcelona, Spain; ELEM Biotech SL, Plaça Pau Vila, 1, Bloc A, Planta 3, Porta 3A1, 08003, Barcelona, Spain
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelstraße 20, 52074, Aachen, Germany
| | - Cristóbal Samaniego
- Barcelona Supercomputing Center, Computer Applications in Science and Engineering, Plaça d'Eusebi Güell, 1-3, 08034, Barcelona, Spain
| |
Collapse
|
6
|
Jajja FA. Comment on: Temporal Trends of the Prevalence of Angina With No Obstructive Coronary Artery Disease (ANOCA). Curr Probl Cardiol 2023; 48:101859. [PMID: 37327834 DOI: 10.1016/j.cpcardiol.2023.101859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 06/04/2023] [Indexed: 06/18/2023]
Affiliation(s)
- Faiza Aman Jajja
- Department of Medicine, Nishtar Medical University, Multan, Pakistan.
| |
Collapse
|
7
|
Snyder Y, Jana S. Strategies for Development of Synthetic Heart Valve Tissue Engineering Scaffolds. PROGRESS IN MATERIALS SCIENCE 2023; 139:101173. [PMID: 37981978 PMCID: PMC10655624 DOI: 10.1016/j.pmatsci.2023.101173] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
The current clinical solutions, including mechanical and bioprosthetic valves for valvular heart diseases, are plagued by coagulation, calcification, nondurability, and the inability to grow with patients. The tissue engineering approach attempts to resolve these shortcomings by producing heart valve scaffolds that may deliver patients a life-long solution. Heart valve scaffolds serve as a three-dimensional support structure made of biocompatible materials that provide adequate porosity for cell infiltration, and nutrient and waste transport, sponsor cell adhesion, proliferation, and differentiation, and allow for extracellular matrix production that together contributes to the generation of functional neotissue. The foundation of successful heart valve tissue engineering is replicating native heart valve architecture, mechanics, and cellular attributes through appropriate biomaterials and scaffold designs. This article reviews biomaterials, the fabrication of heart valve scaffolds, and their in-vitro and in-vivo evaluations applied for heart valve tissue engineering.
Collapse
Affiliation(s)
- Yuriy Snyder
- Department of Bioengineering, University of Missouri, Columbia, MO 65211, USA
| | - Soumen Jana
- Department of Bioengineering, University of Missouri, Columbia, MO 65211, USA
| |
Collapse
|
8
|
Zurmati BM. Letter to the Editor: Long-Term Valve Durability in Patients Undergoing Transcatheter Aortic Valve Implantation - ScienceDirect. Curr Probl Cardiol 2023; 48:101836. [PMID: 37244507 DOI: 10.1016/j.cpcardiol.2023.101836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 05/22/2023] [Indexed: 05/29/2023]
|
9
|
Tao L, Jingyuan Z, Hongjun Z, Yijing L, Yan X, Yu C. Research on fatigue optimization simulation of polymeric heart valve based on the iterative sub-regional thickened method. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3717. [PMID: 37160536 DOI: 10.1002/cnm.3717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 03/08/2023] [Accepted: 04/14/2023] [Indexed: 05/11/2023]
Abstract
Prosthetic polymeric heart valves (PHVs) have the potential to overcome the inherent material and design limitations of traditional valves in the treatment of valvular heart disease; however, their durability remains limited. Optimal design of the valve structure is necessary to improve their durability. This study aimed to enhance the fatigue resistance of PHVs by improving the stress distribution. Iterative subregional thickening of the leaflets was used, and the mechanical stress distribution and hemodynamics of these polymeric tri-leaflet valves were characterized using a fluid-structure interaction approach. Subregional thickening led to a reduction in stress concentration on the leaflet, with the effective orifice area still meeting ISO 5840-3 and the regurgitant volume achieving a similar value to those in previous studies. The maximum stress in the final iteration was reduced by 28% compared with that of the prototype. The proposed method shows potential for analyzing the stress distribution and hemodynamic performance of subregional thickened valves and can further improve the durability of PHVs.
Collapse
Affiliation(s)
- Li Tao
- College of Mechanical Engineering, Sichuan University, Chengdu, China
| | - Zhou Jingyuan
- Department of Applied Mechanics, Sichuan University, Chengdu, China
| | - Zhou Hongjun
- College of Mechanical Engineering, Sichuan University, Chengdu, China
| | - Li Yijing
- College of Mechanical Engineering, Sichuan University, Chengdu, China
| | - Xiong Yan
- College of Mechanical Engineering, Sichuan University, Chengdu, China
| | - Chen Yu
- Department of Applied Mechanics, Sichuan University, Chengdu, China
| |
Collapse
|
10
|
Jajja FA. Comment on: Long-Term Valve Durability in Patients Undergoing Transcatheter Aortic Valve Implantation. Curr Probl Cardiol 2023; 48:101858. [PMID: 37301490 DOI: 10.1016/j.cpcardiol.2023.101858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 06/04/2023] [Indexed: 06/12/2023]
|
11
|
Asadi H, Borazjani I. A contact model based on the coefficient of restitution for simulations of bio-prosthetic heart valves. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3754. [PMID: 37452648 DOI: 10.1002/cnm.3754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 06/18/2023] [Accepted: 06/25/2023] [Indexed: 07/18/2023]
Abstract
A new general contact model is proposed for preventing inter-leaflet penetration of bio-prosthetic heart valves (BHV) at the end of the systole, which has the advantage of applying kinematic constraints directly and creating smooth free edges. At the end of each time step, the impenetrability constraints and momentum exchange between the impacting bodies are applied separately based on the coefficient of restitution. The contact method is implemented in a rotation-free, large deformation, and thin shell finite-element (FE) framework based on loop's subdivision surfaces. A nonlinear, anisotropic material model for a BHV is employed which uses Fung-elastic constitutive laws for in-plane and bending responses, respectively. The contact model is verified and validated against several benchmark problems. For a BHV-specific validation, the computed strains on different regions of a BHV under constant pressure are compared with experimentally measured data. Finally, dynamic simulations of BHV under physiological pressure waveform are performed for symmetrical and asymmetrical fiber orientations incorporating the new contact model and compared with the penalty contact method. The proposed contact model provides the coaptation area of a functioning BHV during the closing phase for both of the fiber orientations. Our results show that fiber orientation affects the dynamic of leaflets during the opening and closing phases. A swirling motion for the BHV with asymmetrical fiber orientation is observed, similar to experimental data. To include the fluid effects, fluid-structure interaction (FSI) simulation of the BHV is performed and compared to the dynamic results.
Collapse
Affiliation(s)
- Hossein Asadi
- J. Mike Walker'66 Department of Mechanical Engineering, Texas A&M University, College Station, Texas, USA
| | - Iman Borazjani
- J. Mike Walker'66 Department of Mechanical Engineering, Texas A&M University, College Station, Texas, USA
| |
Collapse
|
12
|
Huang X, Zhang G, Zhou X, Yang X. A review of numerical simulation in transcatheter aortic valve replacement decision optimization. Clin Biomech (Bristol, Avon) 2023; 106:106003. [PMID: 37245279 DOI: 10.1016/j.clinbiomech.2023.106003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/08/2023] [Accepted: 05/15/2023] [Indexed: 05/30/2023]
Abstract
BACKGROUND Recent trials indicated a further expansion of clinical indication of transcatheter aortic valve replacement to younger and low-risk patients. Factors related to longer-term complications are becoming more important for use in these patients. Accumulating evidence indicates that numerical simulation plays a significant role in improving the outcome of transcatheter aortic valve replacement. Understanding mechanical features' magnitude, pattern, and duration is a topic of ongoing relevance. METHODS We searched the PubMed database using keywords such as "transcatheter aortic valve replacement" and "numerical simulation" and reviewed and summarized relevant literature. FINDINGS This review integrated recently published evidence into three subtopics: 1) prediction of transcatheter aortic valve replacement outcomes through numerical simulation, 2) implications for surgeons, and 3) trends in transcatheter aortic valve replacement numerical simulation. INTERPRETATIONS Our study offers a comprehensive overview of the utilization of numerical simulation in the context of transcatheter aortic valve replacement, and highlights the advantages, potential challenges from a clinical standpoint. The convergence of medicine and engineering plays a pivotal role in enhancing the outcomes of transcatheter aortic valve replacement. Numerical simulation has provided evidence of potential utility for tailored treatments.
Collapse
Affiliation(s)
- Xuan Huang
- Department of Cardiovascular Surgery, West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan, China
| | - Guangming Zhang
- Center for Computational Systems Medicine, School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA
| | - Xiaobo Zhou
- Center for Computational Systems Medicine, School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA; McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA; School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA
| | - Xiaoyan Yang
- Department of Cardiovascular Surgery, West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
13
|
Bahadormanesh N, Tomka B, Abdelkhalek M, Khodaei S, Maftoon N, Keshavarz-Motamed Z. A Doppler-exclusive non-invasive computational diagnostic framework for personalized transcatheter aortic valve replacement. Sci Rep 2023; 13:8033. [PMID: 37198194 PMCID: PMC10192526 DOI: 10.1038/s41598-023-33511-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 04/13/2023] [Indexed: 05/19/2023] Open
Abstract
Given the associated risks with transcatheter aortic valve replacement (TAVR), it is crucial to determine how the implant will affect the valve dynamics and cardiac function, and if TAVR will improve or worsen the outcome of the patient. Effective treatment strategies, indeed, rely heavily on the complete understanding of the valve dynamics. We developed an innovative Doppler-exclusive non-invasive computational framework that can function as a diagnostic tool to assess valve dynamics in patients with aortic stenosis in both pre- and post-TAVR status. Clinical Doppler pressure was reduced by TAVR (52.2 ± 20.4 vs. 17.3 ± 13.8 [mmHg], p < 0.001), but it was not always accompanied by improvements in valve dynamics and left ventricle (LV) hemodynamics metrics. TAVR had no effect on LV workload in 4 patients, and LV workload post-TAVR significantly rose in 4 other patients. Despite the group level improvements in maximum LV pressure (166.4 ± 32.2 vs 131.4 ± 16.9 [mmHg], p < 0.05), only 5 of the 12 patients (41%) had a decrease in LV pressure. Moreover, TAVR did not always improve valve dynamics. TAVR did not necessarily result in a decrease (in 9 out of 12 patients investigated in this study) in major principal stress on the aortic valve leaflets which is one of the main contributors in valve degeneration and, consequently, failure of heart valves. Diastolic stresses increased significantly post-TAVR (34%, 109% and 81%, p < 0.001) for each left, right and non-coronary leaflets respectively. Moreover, we quantified the stiffness and material properties of aortic valve leaflets which correspond with the reduced calcified region average stiffness among leaflets (66%, 74% and 62%; p < 0.001; N = 12). Valve dynamics post-intervention should be quantified and monitored to ensure the improvement of patient conditions and prevent any further complications. Improper evaluation of biomechanical valve features pre-intervention as well as post-intervention may result in harmful effects post-TAVR in patients including paravalvular leaks, valve degeneration, failure of TAVR and heart failure.
Collapse
Affiliation(s)
- Nikrouz Bahadormanesh
- Department of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada
| | - Benjamin Tomka
- Department of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada
| | | | - Seyedvahid Khodaei
- Department of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada
| | - Nima Maftoon
- Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada
- Centre for Bioengineering and Biotechnology, University of Waterloo, Waterloo, ON, Canada
| | - Zahra Keshavarz-Motamed
- Department of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- School of Computational Science and Engineering, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
14
|
Affiliation(s)
- Kush P Patel
- Structural Heart Intervention Department, Barts Heart Centre, London, UK.,Barts Heart Centre, Barts Health NHS Trust, London, UK
| | - Andreas Baumbach
- Barts Heart Centre, Barts Health NHS Trust, London, UK .,Cardiology, Queen Mary University of London, London, UK
| |
Collapse
|
15
|
Bahadormanesh N, Tomka B, Kadem M, Khodaei S, Keshavarz-Motamed Z. An ultrasound-exclusive non-invasive computational diagnostic framework for personalized cardiology of aortic valve stenosis. Med Image Anal 2023; 87:102795. [PMID: 37060702 DOI: 10.1016/j.media.2023.102795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 02/27/2023] [Accepted: 03/06/2023] [Indexed: 03/30/2023]
Abstract
Aortic stenosis (AS) is an acute and chronic cardiovascular disease and If left untreated, 50% of these patients will die within two years of developing symptoms. AS is characterized as the stiffening of the aortic valve leaflets which restricts their motion and prevents the proper opening under transvalvular pressure. Assessments of the valve dynamics, if available, would provide valuable information about the patient's state of cardiac deterioration as well as heart recovery and can have incredible impacts on patient care, planning interventions and making critical clinical decisions with life-threatening risks. Despite remarkable advancements in medical imaging, there are no clinical tools available to quantify valve dynamics invasively or noninvasively. In this study, we developed a highly innovative ultrasound-based non-invasive computational framework that can function as a diagnostic tool to assess valve dynamics (e.g. transient 3-D distribution of stress and displacement, 3-D deformed shape of leaflets, geometric orifice area and angular positions of leaflets) for patients with AS at no risk to the patients. Such a diagnostic tool considers the local valve dynamics and the global circulatory system to provide a platform for testing the intervention scenarios and evaluating their effects. We used clinical data of 12 patients with AS not only to validate the proposed framework but also to demonstrate its diagnostic abilities by providing novel analyses and interpretations of clinical data in both pre and post intervention states. We used transthoracic echocardiogram (TTE) data for the developments and transesophageal echocardiography (TEE) data for validation.
Collapse
Affiliation(s)
| | - Benjamin Tomka
- Department of Mechanical Engineering, McMaster University Hamilton, ON, Canada
| | - Mason Kadem
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - Seyedvahid Khodaei
- Department of Mechanical Engineering, McMaster University Hamilton, ON, Canada
| | - Zahra Keshavarz-Motamed
- Department of Mechanical Engineering, McMaster University Hamilton, ON, Canada; School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; School of Computational Science and Engineering, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
16
|
Sun M, Elkhodiry M, Shi L, Xue Y, Abyaneh MH, Kossar AP, Giuglaris C, Carter SL, Li RL, Bacha E, Ferrari G, Kysar J, Myers K, Kalfa D. A biomimetic multilayered polymeric material designed for heart valve repair and replacement. Biomaterials 2022; 288:121756. [PMID: 36041938 PMCID: PMC9801615 DOI: 10.1016/j.biomaterials.2022.121756] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 08/02/2022] [Accepted: 08/17/2022] [Indexed: 01/03/2023]
Abstract
Materials currently used to repair or replace a heart valve are not durable. Their limited durability related to structural degeneration or thrombus formation is attributed to their inadequate mechanical properties and biocompatibility profiles. Our hypothesis is that a biostable material that mimics the structure, mechanical and biological properties of native tissue will improve the durability of these leaflets substitutes and in fine improve the patient outcome. Here, we report the development, optimization, and testing of a biomimetic, multilayered material (BMM), designed to replicate the native valve leaflets. Polycarbonate urethane and polycaprolactone have been processed as film, foam, and aligned fibers to replicate the leaflet's architecture and anisotropy, through solution casting, lyophilization, and electrospinning. Compared to the commercialized materials, our BMMs exhibited an anisotropic behavior and a closer mechanical performance to the aortic leaflets. The material exhibited superior biostability in an accelerated oxidization environment. It also displayed better resistance to protein adsorption and calcification in vitro and in vivo. These results will pave the way for a new class of advanced synthetic material with long-term durability for surgical valve repair or replacement.
Collapse
Affiliation(s)
- Mingze Sun
- Department of Surgery, Columbia University, New York, NY, USA
| | | | - Lei Shi
- Department of Mechanical Engineering, Columbia University, New York, NY, USA
| | - Yingfei Xue
- Department of Surgery, Columbia University, New York, NY, USA
| | | | | | | | | | - Richard L. Li
- Department of Mechanical Engineering, Columbia University, New York, NY, USA
| | - Emile Bacha
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Irving Medical Center, New York, NY, USA
| | | | - Jeffrey Kysar
- Department of Mechanical Engineering, Columbia University, New York, NY, USA
| | - Kristin Myers
- Department of Mechanical Engineering, Columbia University, New York, NY, USA
| | - David Kalfa
- Department of Surgery, Columbia University, New York, NY, USA,Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Irving Medical Center, New York, NY, USA,Corresponding author. Pediatric Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA. (D. Kalfa)
| |
Collapse
|
17
|
Nappi F, Avtaar Singh SS, Nappi P, Fiore A. Biomechanics of Transcatheter Aortic Valve Implant. Bioengineering (Basel) 2022; 9:bioengineering9070299. [PMID: 35877350 PMCID: PMC9312295 DOI: 10.3390/bioengineering9070299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/28/2022] [Accepted: 06/29/2022] [Indexed: 11/16/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has grown exponentially within the cardiology and cardiac surgical spheres. It has now become a routine approach for treating aortic stenosis. Several concerns have been raised about TAVI in comparison to conventional surgical aortic valve replacement (SAVR). The primary concerns regard the longevity of the valves. Several factors have been identified which may predict poor outcomes following TAVI. To this end, the lesser-used finite element analysis (FEA) was used to quantify the properties of calcifications which affect TAVI valves. This method can also be used in conjunction with other integrated software to ascertain the functionality of these valves. Other imaging modalities such as multi-detector row computed tomography (MDCT) are now widely available, which can accurately size aortic valve annuli. This may help reduce the incidence of paravalvular leaks and regurgitation which may necessitate further intervention. Structural valve degeneration (SVD) remains a key factor, with varying results from current studies. The true incidence of SVD in TAVI compared to SAVR remains unclear due to the lack of long-term data. It is now widely accepted that both are part of the armamentarium and are not mutually exclusive. Decision making in terms of appropriate interventions should be undertaken via shared decision making involving heart teams.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord, 93200 Saint-Denis, France
- Correspondence: ; Tel.: +33-149334104; Fax: +33-149334119
| | | | - Pierluigi Nappi
- Department of Clinical and Experimental Medicine, University of Messina, 98122 Messina, Italy;
| | - Antonio Fiore
- Department of Cardiac Surgery, Hôpitaux Universitaires Henri Mondor, Assistance Publique-Hôpitaux de Paris, 94000 Creteil, France;
| |
Collapse
|
18
|
The 10-year horizon: Survival and structural valve degeneration in first-generation transcatheter aortic valves. Arch Cardiovasc Dis 2022; 115:369-376. [DOI: 10.1016/j.acvd.2022.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 04/05/2022] [Accepted: 04/06/2022] [Indexed: 11/23/2022]
|
19
|
Song M, Tang Z, Liu Y, Xie X, Qi X, Wu Q, Jiang Z, Wu Z, Qian T. Yak Pericardium as an Alternative Biomaterial for Transcatheter Heart Valves. Front Bioeng Biotechnol 2021; 9:766991. [PMID: 34820366 PMCID: PMC8607193 DOI: 10.3389/fbioe.2021.766991] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 10/20/2021] [Indexed: 11/13/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has received much attention and development in the past decade due to its lower risk of complication and infections compared to a traditional open thoracotomy. However, the current commercial transcatheter heart valve does not fully meet clinical needs; therefore, new biological materials must be found in order to meet these requirements. We have discovered a new type of biological material, the yak pericardium. This current research studied its extracellular matrix structure, composition, mechanical properties, and amino acid content. Folding experiment was carried out to analyze the structure and mechanics after folding. We also conducted a subcutaneous embedding experiment to analyze the inflammatory response and calcification after implantation. Australian bovine pericardium, local bovine pericardium, and porcine pericardium were used as controls. The overall structure of the yak pericardium is flat, the collagen runs regularly, it has superior mechanical properties, and the average thickness is significantly lower than that of the Australian bovine and the local bovine pericardium control groups. The yak pericardium has a higher content of elastic fibers, showing that it has a better compression resistance effect during the folding experiment as well as having less expression of transplantation-related antigens. We conducted in vivo experiments and found that the yak pericardium has less inflammation and a lower degree of calcification. In summary, the yak pericardium, which is thin and strong, has lower immunogenicity and outstanding anti-calcification effects may be an excellent candidate valve leaflet material for TAVI.
Collapse
Affiliation(s)
- Mingzhe Song
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Zhenjie Tang
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Yuhong Liu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Xinlong Xie
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Xiaoke Qi
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Qiying Wu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Zhenlin Jiang
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Zhongshi Wu
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| | - Tao Qian
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, China.,Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, China
| |
Collapse
|
20
|
Zhang W, Motiwale S, Hsu MC, Sacks MS. Simulating the time evolving geometry, mechanical properties, and fibrous structure of bioprosthetic heart valve leaflets under cyclic loading. J Mech Behav Biomed Mater 2021; 123:104745. [PMID: 34482092 PMCID: PMC8482999 DOI: 10.1016/j.jmbbm.2021.104745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 07/15/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
Currently, the most common replacement heart valve design is the 'bioprosthetic' heart valve (BHV), which has important advantages in that it does not require permanent anti-coagulation therapy, operates noiselessly, and has blood flow characteristics similar to the native valve. BHVs are typically fabricated from glutaraldehyde-crosslinked pericardial xenograft tissue biomaterials (XTBs) attached to a rigid, semi-flexible, or fully collapsible stent in the case of the increasingly popular transcutaneous aortic valve replacement (TAVR). While current TAVR assessments are positive, clinical results to date are generally limited to <2 years. Since TAVR leaflets are constructed using thinner XTBs, their mechanical demands are substantially greater than surgical BHV due to the increased stresses during in vivo operation, potentially resulting in decreased durability. Given the functional complexity of heart valve operation, in-silico predictive simulations clearly have potential to greatly improve the TAVR development process. As such simulations must start with accurate material models, we have developed a novel time-evolving constitutive model for pericardial xenograft tissue biomaterials (XTB) utilized in BHV (doi: 10.1016/j.jmbbm.2017.07.013). This model was able to simulate the observed tissue plasticity effects that occur in approximately in the first two years of in vivo function (50 million cycles). In the present work, we implemented this model into a complete simulation pipeline to predict the BHV time evolving geometry to 50 million cycles. The pipeline was implemented within an isogeometric finite element formulation that directly integrated our established BHV NURBS-based geometry (doi: 10.1007/s00466-015-1166-x). Simulations of successive loading cycles indicated continual changes in leaflet shape, as indicated by spatially varying increases in leaflet curvature. While the simulation model assumed an initial uniform fiber orientation distribution, anisotropic regional changes in leaflet tissue plastic strain induced a complex changes in regional fiber orientation. We have previously noted in our time-evolving constitutive model that the increases in collagen fiber recruitment with cyclic loading placed an upper bound on plastic strain levels. This effect was manifested by restricting further changes in leaflet geometry past 50 million cycles. Such phenomena was accurately captured in the valve-level simulations due to the use of a tissue-level structural-based modeling approach. Changes in basic leaflet dimensions agreed well with extant experimental studies. As a whole, the results of the present study indicate the complexity of BHV responses to cyclic loading, including changes in leaflet shape and internal fibrous structure. It should be noted that the later effect also influences changes in local mechanical behavior (i.e. changes in leaflet anisotropic tissue stress-strain relationship) due to internal fibrous structure resulting from plastic strains. Such mechanism-based simulations can help pave the way towards the application of sophisticated simulation technologies in the development of replacement heart valve technology.
Collapse
Affiliation(s)
- Will Zhang
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712-0027, USA
| | - Shruti Motiwale
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712-0027, USA
| | - Ming-Chen Hsu
- Computational Fluid-Structure Interaction Laboratory, Department of Mechanical Engineering, Iowa State University, Ames, IA 50011-2030, USA
| | - Michael S Sacks
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712-0027, USA.
| |
Collapse
|
21
|
Xuan Y, Dvir D, Wisneski AD, Wang Z, Ye J, Guccione JM, Ge L, Tseng EE. Impact of Transcatheter Aortic Valve Size on Leaflet Stresses: Implications for Durability and Optimal Grey Zone Sizing. ACTA ACUST UNITED AC 2021; 6:64-71. [PMID: 34708162 DOI: 10.4244/aij-d-19-00005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Aims As indications for transcatheter aortic valve replacement (TAVR) continue to expand towards younger and lower-risk patients, durability becomes an increasingly important question. Durability decreases as leaflet stresses increase, but the impact of transcatheter heart valve (THV) size on stress is unknown. Patient annulus sizes can fall within "grey zones" between 2 TAVR sizes. Our aim was to examine the impact of balloon-expandable THV size on leaflet stresses. Methods and Results SapienXT 23mm, 26mm, and 29mm sizes (Edwards Lifesciences, Inc) underwent micro-computed tomography scanning to create THV computational models then loaded to systemic pressure using finite element software. THV leaflet maximum principal stresses were 1.69MPa (23mm), 1.70MPa (26mm), and 2.12MPa (29mm) at mean arterial pressure. For intermediate annulus sizes, undersizing the larger THV yielded lower leaflet stresses than oversizing the smaller THV. Conclusions Increasing THV size yielded greater leaflet maximum principal stresses, which could suggest a relationship between THV size and long-term durability.. For annulus "grey zones" sizes, undersizing the larger THV resulted in lower leaflet stresses than oversizing the smaller THV. These results may influence optimal device sizing, as THV durability remains an important, unanswered question.
Collapse
Affiliation(s)
- Yue Xuan
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Danny Dvir
- Division of Cardiology, University of Washington, Seattle, WA
| | - Andrew D Wisneski
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Zhongjie Wang
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Jian Ye
- Division of Cardiovascular Surgery, St. Paul's Hospital and Vancouver General Hospital, Vancouver, BC, Canada
| | - Julius M Guccione
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Liang Ge
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Elaine E Tseng
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| |
Collapse
|
22
|
Sá MP, Ramlawi B, Sicouri S, Torregrossa G, Al Abri Q, Kempfert J, Kofler M, Falk V, Unbehaun A, Van Praet KM. Lifetime management of aortic valve disease: Aligning surgical and transcatheter armamentarium to set the tone for the present and the future. J Card Surg 2021; 37:205-213. [PMID: 34697831 DOI: 10.1111/jocs.16110] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 10/13/2021] [Indexed: 12/16/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) has already received the green light for high-, intermediate- and low-risk profiles and is an alternative for all patients regardless of age. It is clear that there has been a push towards the use of TAVR in younger and younger patients (<65 years), which has never been formally tested in randomized controlled trials but seems inevitable as TAVR technology makes steady progress. Lifetime management as a concept will set the tone in the field of the structural heart. Some subjects in this scenario arise, including the importance of optimized prosthetic hemodynamics for lifetime care; surgical procedures in the aortic root; management of structural valve degeneration with valve-in-valve procedures (TAVR-in-surgical aortic valve replacement [SAVR] and TAVR-in-TAVR) and redo SAVR; commissural alignment and cusp overlap for TAVR; the rise in the number of surgical procedures for TAVR explantation; and the renewed interest in the Ross procedure. This article reviews all these issues which will become commonplace during heart team meetings and preoperative conversations with patients in the coming years.
Collapse
Affiliation(s)
- Michel Pompeu Sá
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Basel Ramlawi
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Serge Sicouri
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Gianluca Torregrossa
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Qasim Al Abri
- Department of Cardiothoracic Surgery, DeBakey Heart and Vascular Center, Houston Methodist Hospital, Houston, Texas, USA
| | - Jörg Kempfert
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
| | - Markus Kofler
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany.,Berlin Institute of Health, Berlin, Germany.,Department of Cardiovascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Department of Health Sciences and Technology, Institute of Translational Medicine, Swiss Federal Institute of Technology, Translational Cardiovascular Technologies, Zurich, Switzerland
| | - Axel Unbehaun
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
| | - Karel M Van Praet
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
| |
Collapse
|
23
|
Narayan P. Structural valve degeneration in the transcatheter mitral valve implantation era. J Card Surg 2021; 36:4431-4433. [PMID: 34374123 DOI: 10.1111/jocs.15911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 08/05/2021] [Indexed: 11/29/2022]
Abstract
Structural valve degeneration of biological valves continues to be a persistent problem and has assumed greater importance with the advent of transcatheter valve implantation techniques. Considerable variability exists among different studies in reporting the incidence of structural valve degeneration and differentiation with nonstructural valve degeneration and bio-prosthetic valve failures is important. Moreover, the pathological basis of structural valve degeneration is still not completely understood. Theoretically, trans-catheter implanted valves may be more prone to degeneration compared to surgically implanted biological valves. Measures to reduce structural valve degeneration are imperative, irrespective of the technique of valve implantation.
Collapse
Affiliation(s)
- Pradeep Narayan
- Department of Cardiac Surgery, Rabindranath Tagore International Institute of Cardiac Sciences, Narayana Health, Kolkata, India
| |
Collapse
|
24
|
Koneru S. A New Dimension in Treating Aortic Stenosis: DVI in the Battle of TAVR Versus SAVR. JACC Cardiovasc Interv 2021; 14:1607-1609. [PMID: 34217632 DOI: 10.1016/j.jcin.2021.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/27/2022]
Affiliation(s)
- Srikanth Koneru
- Division of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, Texas, USA; Department of Cardiology, Texas Heart Institute, Houston, Texas, USA.
| |
Collapse
|
25
|
Lee JH, Scotten LN, Hunt R, Caranasos TG, Vavalle JP, Griffith BE. Bioprosthetic aortic valve diameter and thickness are directly related to leaflet fluttering: Results from a combined experimental and computational modeling study. JTCVS OPEN 2021; 6:60-81. [PMID: 35211686 PMCID: PMC8864557 DOI: 10.1016/j.xjon.2020.09.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Bioprosthetic heart valves (BHVs) are commonly used in surgical and percutaneous valve replacement. The durability of percutaneous valve replacement is unknown, but surgical valves have been shown to require reintervention after 10 to 15 years. Further, smaller-diameter surgical BHVs generally experience higher rates of prosthesis-patient mismatch, which leads to higher rates of failure. Bioprosthetic aortic valves can flutter in systole, and fluttering is associated with fatigue and failure in flexible structures. The determinants of flutter in BHVs have not been well characterized, despite their potential to influence durability. METHODS We use an experimental pulse duplicator and a computational fluid-structure interaction model of this system to study the role of device geometry on BHV dynamics. The experimental system mimics physiological conditions, and the computational model enables precise control of leaflet biomechanics and flow conditions to isolate the effects of variations in BHV geometry on leaflet dynamics. RESULTS Both experimental and computational models demonstrate that smaller-diameter BHVs yield markedly higher leaflet fluttering frequencies across a range of conditions. The computational model also predicts that fluttering frequency is directly related to leaflet thickness. A scaling model is introduced that rationalizes these findings. CONCLUSIONS We systematically characterize the influence of BHV diameter and leaflet thickness on fluttering dynamics. Although this study does not determine how flutter influences device durability, increased flutter in smaller-diameter BHVs may explain how prosthesis-patient mismatch could induce BHV leaflet fatigue and failure. Ultimately, understanding the effects of device geometry on leaflet kinematics may lead to more durable valve replacements.
Collapse
Affiliation(s)
- Jae H Lee
- Department of Mathematics, University of North Carolina, Chapel Hill, NC
| | | | - Robert Hunt
- Department of Mathematics, University of North Carolina, Chapel Hill, NC
| | - Thomas G Caranasos
- Division of Cardiothoracic Surgery, Department of Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - John P Vavalle
- Division of Cardiology, Department of Medicine, University of North Carolina School of Medicine, Chapel Hill, NC
| | - Boyce E Griffith
- Department of Mathematics, University of North Carolina, Chapel Hill, NC.,Computational Medicine Program and McAllister Heart Institute, University of North Carolina School of Medicine, Chapel Hill, NC
| |
Collapse
|
26
|
Porcine and bovine aortic valve comparison for surgical optimization: A fluid-structure interaction modeling study. Int J Cardiol 2021; 334:88-95. [PMID: 33932427 DOI: 10.1016/j.ijcard.2021.04.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 03/28/2021] [Accepted: 04/26/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Porcine aortic valve (PAV) and bovine aortic valve (BAV) are commonly used in aortic valve replacement (AVR) surgeries. A detailed comparison for their hemodynamic and structural stress/strain performances would help to better understand valve cardiac function and select valve type and size for AVR outcome optimizations. METHODS Eight fluid-structure interaction models were constructed to compare hemodynamic and stress/strain behaviors of PAV and BAV with 4 sizes (19, 21, 23, and 25 mm). Blood flow velocity, systolic cross-valve pressure gradient (SCVPG), geometric orifice area (GOA), flow shear stresses (FSS), and stress/strain were obtained for comparison. RESULTS Compared with PAV, BAV has better hemodynamic performance, with lower maximum flow velocity (7.17%) and pressure (9.82%), smaller pressure gradient (mean and peak SCVPG: 8.92% and 9.28%), larger GOA (9.56%) and lower FSS (6.61%). The averages of the mean and peak net pressure gradient values from 4 BAV models were 8.10% and 8.35% lower than that from PAV models. Larger valve sizes for both PAV and BAV had improved hemodynamic performance. Maximum flow velocity, pressure, mean SCVPG and maximum FSS from 25 mm BAV were 36.80%, 15.81%, 39.05% and 38.83% lower than those from 19 mm BAV. The GOA of PAV and BAV 25 mm Valve were 43.75% and 33.07% larger than 19 mm valves, respectively. BAV has lower stress on the leaflets than PAV. CONCLUSIONS BAV had better hemodynamic performance and lower leaflets stress than PAV. More patient studies are needed to validate our findings.
Collapse
|
27
|
Early and mid-term results of transcatheter aortic valve implantation and valve durability assessment. Heart Vessels 2021; 36:1566-1573. [PMID: 33871699 DOI: 10.1007/s00380-021-01842-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
This study aimed to evaluate the early and mid-term outcomes of transcatheter aortic valve implantation (TAVI) and to assess valve durability. A total of 146 consecutive patients who underwent TAVI for severe aortic stenosis between October 2013 and August 2018 were retrospectively reviewed. All patients (mean age, 84 ± 6 years; age range 53-98 years; 42 males [28.7%]) had multiple comorbidities, with a mean logistic EuroSCORE of 30.9 ± 17.4%. Eighteen patients (12.3%) were aged 90 years or over. Five in-hospital deaths (3.4%) occurred, and 36 patients (24.7%) experienced major TAVI-related complications. With the transfemoral approach, 10 patients had major vascular complications, which mostly occurred with first-generation devices (n = 9) but less commonly with new-generation low-profile devices (P = 0.0078). During a follow-up period of 580 ± 450 (11-1738) days, 29 late deaths occurred. The survival rate was 86.0%, 78.0%, and 61.7% at 1, 2, and 3 years, respectively. Multivariate Cox hazard regression analysis revealed that more-than-moderate tricuspid regurgitation was the only independent risk factor for late deaths due to any cause (hazard ratio, 3.145; 95% confidence interval, 1.129-8.762; P = 0.0283). No statistically significant differences between post-TAVI before discharge from the hospital and at 4 years after TAVI were observed with respect to aortic valve area (1.76 ± 0.49 cm2 vs. 1.64 ± 0.38 cm2; P = 0.1871) and mean pressure gradient (10.0 ± 4.6 mmHg vs. 7.9 ± 3.3 mmHg; P = 0.5032). TAVI was a feasible method with acceptable early and mid-term outcomes and valve durability for at least 4 years in poor-risk patients. Further close follow-up is essential to evaluate late outcomes and valve durability.
Collapse
|
28
|
Ferreira-Neto AN, Rodriguez-Gabella T, Guimaraes L, Freitas-Ferraz A, Bernier M, Figueiredo Guimaraes C, Pasian S, Paradis JM, Delarochellière R, Dumont E, Mohammadi S, Kalavrouziotis D, Côté M, Pibarot P, Rodés-Cabau J. Multimodality evaluation of transcatheter structural valve degeneration at long-term follow-up. ACTA ACUST UNITED AC 2021; 74:247-256. [DOI: 10.1016/j.rec.2020.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Accepted: 01/20/2020] [Indexed: 11/24/2022]
|
29
|
Ferreira-Neto AN, Rodriguez-Gabella T, Guimaraes L, Freitas-Ferraz A, Bernier M, Figueiredo Guimaraes C, Pasian S, Paradis JM, Delarochellière R, Dumont E, Mohammadi S, Kalavrouziotis D, Côté M, Pibarot P, Rodés-Cabau J. Evaluación multimodal de la degeneración estructural de válvulas percutáneas en el seguimiento a largo plazo. Rev Esp Cardiol 2021. [DOI: 10.1016/j.recesp.2020.01.029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
30
|
Transcatheter Heart Valve Downstream Fluid Dynamics in an Accelerated Evaluation Environment. Ann Biomed Eng 2021; 49:2170-2182. [PMID: 33638029 DOI: 10.1007/s10439-021-02751-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 02/12/2021] [Indexed: 10/22/2022]
Abstract
Transcatheter aortic valve replacements (TAVRs) provide minimally invasive delivery of bioprosthetic heart valves (BHVs) for the treatment of aortic valve disease. While surgical BHVs show efficacy for 8-10 years, long-term TAVR durability remains unknown. Pre-clinical testing evaluates BHV durability in an ISO:5840 compliant accelerated wear tester (AWT), yet, the design and development of AWTs and their accuracy in predicting in vivo performance, is unclear. As a result of limited knowledge on AWT environment and BHV loading, durability assessment of candidate valves remains fundamentally empirical. For the first time, high-speed particle image velocimetry quantified an ISO:5840 compliant downstream AWT velocity field, Reynolds stresses, and turbulence intensity. TAVR enface imaging quantified the orifice area and estimated the flow rate. When valve area and flow rate were at their maximum during peak systole (1.49 cm2 and 16.05 L/min, respectively), central jet velocity, Reynolds normal and shear stress, and turbulence intensity grew to 0.50 m/s, 265.1 Pa, 124.6 Pa, and 37.3%, respectively. During diastole, unique AWT recirculation produced retrograde flow and the directional changes created eddies. These novel AWT findings demonstrated a substantially reduced valve fully loaded period and pressure not matching in vivo or in vitro studies, despite the comparable fluid environment and TAVR motion.
Collapse
|
31
|
Demir OM, Taramasso M. Structural Valve Degeneration in the Era of Transcatheter Aortic Valve Replacement. JACC Case Rep 2020; 2:2166-2168. [PMID: 34317130 PMCID: PMC8299842 DOI: 10.1016/j.jaccas.2020.09.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Affiliation(s)
- Ozan M. Demir
- Department of Cardiology, St. Thomas’ Hospital, London, United Kingdom
| | - Maurizio Taramasso
- University Heart Center, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
32
|
Chambers JB. Leaflet thrombosis in transcatheter aortic valves implants: a new marker of risk? Eur Heart J Cardiovasc Imaging 2020; 21:1090-1091. [PMID: 32617575 DOI: 10.1093/ehjci/jeaa158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 05/08/2020] [Accepted: 05/13/2020] [Indexed: 11/13/2022] Open
Affiliation(s)
- John B Chambers
- Cardiothoracic Centre, Guy's and St Thomas' Hospitals, Westminster Bridge Road, London SE1 7EH, UK
| |
Collapse
|
33
|
Simonato M, Dvir D. The Ten Commandments of Aortic Valve-in-Valve. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2020; 15:397-405. [PMID: 32955362 DOI: 10.1177/1556984520951874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Matheus Simonato
- 28105 Escola Paulista de Medicina Universidade Federal de São Paulo, Brazil
| | - Danny Dvir
- 26743 Jesselson Integrated Heart Centre, ShaareZedek Medical Center, Hebrew University, Jerusalem, Israel.,Division of Cardiology, University of Washington, Seattle, WA, USA
| |
Collapse
|
34
|
Kostyunin AE, Yuzhalin AE, Rezvova MA, Ovcharenko EA, Glushkova TV, Kutikhin AG. Degeneration of Bioprosthetic Heart Valves: Update 2020. J Am Heart Assoc 2020; 9:e018506. [PMID: 32954917 PMCID: PMC7792365 DOI: 10.1161/jaha.120.018506] [Citation(s) in RCA: 130] [Impact Index Per Article: 32.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The implantation of bioprosthetic heart valves (BHVs) is increasingly becoming the treatment of choice in patients requiring heart valve replacement surgery. Unlike mechanical heart valves, BHVs are less thrombogenic and exhibit superior hemodynamic properties. However, BHVs are prone to structural valve degeneration (SVD), an unavoidable condition limiting graft durability. Mechanisms underlying SVD are incompletely understood, and early concepts suggesting the purely degenerative nature of this process are now considered oversimplified. Recent studies implicate the host immune response as a major modality of SVD pathogenesis, manifested by a combination of processes phenocopying the long‐term transplant rejection, atherosclerosis, and calcification of native aortic valves. In this review, we summarize and critically analyze relevant studies on (1) SVD triggers and pathogenesis, (2) current approaches to protect BHVs from calcification, (3) obtaining low immunogenic BHV tissue from genetically modified animals, and (4) potential strategies for SVD prevention in the clinical setting.
Collapse
Affiliation(s)
- Alexander E Kostyunin
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation
| | - Arseniy E Yuzhalin
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation.,Department of Molecular and Cellular Oncology The University of Texas MD Anderson Cancer Center Houston TX
| | - Maria A Rezvova
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation
| | - Evgeniy A Ovcharenko
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation
| | - Tatiana V Glushkova
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation
| | - Anton G Kutikhin
- Department of Experimental Medicine Research Institute for Complex Issues of Cardiovascular Diseases Kemerovo Russian Federation
| |
Collapse
|
35
|
Samarendra P. A Precipitous Decision: Transcatheter Aortic Valve Replacement in Low-Risk Patients. Cardiol Res 2020; 11:200-203. [PMID: 32494331 PMCID: PMC7239588 DOI: 10.14740/cr1062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 04/15/2020] [Indexed: 11/22/2022] Open
Affiliation(s)
- Padmaraj Samarendra
- Division of Cardiology, Pittsburgh V.A. Medical Center, University of Pittsburgh, Pittsburgh, PA 15260, USA.
| |
Collapse
|
36
|
Xuan Y, Dvir D, Wang Z, Ye J, Guccione JM, Ge L, Tseng EE. Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves. Interact Cardiovasc Thorac Surg 2020; 30:879-886. [PMID: 32248231 PMCID: PMC7248644 DOI: 10.1093/icvts/ivaa037] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 01/10/2020] [Accepted: 02/04/2020] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVES Transcatheter aortic valve replacement (TAVR) is established therapy for severe aortic stenosis patients with intermediate-, high- and prohibitive-risk for surgery. A significant challenge when expanding TAVR to low-risk and younger patients is the unknown long-term durability. High leaflet stresses have been associated with surgical bioprosthetic valve degeneration. In this study, we examined the impact of changes in valve design across 3 generations of same-sized TAVR devices on stent and leaflet stresses. METHODS The 26-mm Edwards SAPIEN, 23, 26 and 29 mm SAPIEN XT (XT) and 26 mm SAPIEN 3 (S3) (n = 1 each) underwent micro-computed tomography (micro-CT) scanning. Dynamic finite element computational simulations of 23-26 mm SAPIEN, 23-29 mm XT and 23-29 mm S3 were performed with physiological loading and micro-CT or scaled geometries. RESULTS Peak stresses were concentrated in the commissure area and along the bottom of the suture, representing areas most likely to develop structural valve degeneration across TAVR generations. Latest-generation S3 showed greatest 99th percentile principal stress on commissural leaflets for 26 and 29 mm, and increased stresses over XT for 23 mm. Percentage of higher stress areas within the leaflets steadily increased across generations, 3.8%, 3.9% and 5.7%, respectively, for 26 mm SAPIEN, XT and S3 with similar trend for 29-mm valves. CONCLUSIONS Using computational simulations based on high-fidelity modelling of balloon-expandable TAVRs, our study demonstrated that maximum stress areas existed in similar leaflet locations across SAPIEN generations, while the latest model S3 had the highest magnitude for both 26- and 29-mm valves. S3 also had the largest area of higher stresses than other generations, which would be prone to degeneration. Our study coupled with future long-term clinical outcomes >10 years will provide insight on biomechanics of TAVR degeneration.
Collapse
Affiliation(s)
- Yue Xuan
- Division of Cardiothoracic Surgery, University of California San Francisco and San Francisco VA Medical Center, San Francisco, CA, USA
| | - Danny Dvir
- Division of Cardiology, University of Washington, Seattle, WA, USA
| | - Zhongjie Wang
- Division of Cardiothoracic Surgery, University of California San Francisco and San Francisco VA Medical Center, San Francisco, CA, USA
| | - Jian Ye
- Department of Surgery, St Paul’s Hospital, Vancouver, BC, Canada
| | - Julius M Guccione
- Division of Cardiothoracic Surgery, University of California San Francisco and San Francisco VA Medical Center, San Francisco, CA, USA
| | - Liang Ge
- Division of Cardiothoracic Surgery, University of California San Francisco and San Francisco VA Medical Center, San Francisco, CA, USA
| | - Elaine E Tseng
- Division of Cardiothoracic Surgery, University of California San Francisco and San Francisco VA Medical Center, San Francisco, CA, USA
| |
Collapse
|
37
|
Durand E, Sokoloff A, Urena-Alcazar M, Chevalier B, Chassaing S, Didier R, Tron C, Litzler PY, Bouleti C, Himbert D, Hovasse T, Bar O, Avinée G, Iung B, Blanchard D, Gilard M, Cribier A, Lefevre T, Eltchaninoff H. Assessment of Long-Term Structural Deterioration of Transcatheter Aortic Bioprosthetic Valves Using the New European Definition. Circ Cardiovasc Interv 2020; 12:e007597. [PMID: 30998397 DOI: 10.1161/circinterventions.118.007597] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. METHODS AND RESULTS Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. CONCLUSIONS The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.
Collapse
Affiliation(s)
- Eric Durand
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Anastasia Sokoloff
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Marina Urena-Alcazar
- Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Faculté de Médecine Paris-Diderot University, Department of Cardiology, DHU Fire, INSERM U1148, Paris-Diderot University Paris, France (M.U.-A., C.B., D.H., B.I.)
| | - Bernard Chevalier
- Institut Hospitalier Jacques Cartier, Ramsay Générale de Santé, Department of Cardiology, Massy, France (B.C., T.H., T.L.)
| | - Stephan Chassaing
- Clinique Saint Gatien, Department of Cardiology, Tours, France (S.C., O.B., D.B.)
| | - Romain Didier
- Brest University Hospital, Department of Cardiology, France (R.D., M.G.)
| | - Christophe Tron
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Pierre-Yves Litzler
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Claire Bouleti
- Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Faculté de Médecine Paris-Diderot University, Department of Cardiology, DHU Fire, INSERM U1148, Paris-Diderot University Paris, France (M.U.-A., C.B., D.H., B.I.)
| | - Dominique Himbert
- Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Faculté de Médecine Paris-Diderot University, Department of Cardiology, DHU Fire, INSERM U1148, Paris-Diderot University Paris, France (M.U.-A., C.B., D.H., B.I.)
| | - Thomas Hovasse
- Institut Hospitalier Jacques Cartier, Ramsay Générale de Santé, Department of Cardiology, Massy, France (B.C., T.H., T.L.)
| | - Olivier Bar
- Clinique Saint Gatien, Department of Cardiology, Tours, France (S.C., O.B., D.B.)
| | - Guillaume Avinée
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Bernard Iung
- Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Faculté de Médecine Paris-Diderot University, Department of Cardiology, DHU Fire, INSERM U1148, Paris-Diderot University Paris, France (M.U.-A., C.B., D.H., B.I.)
| | - Didier Blanchard
- Clinique Saint Gatien, Department of Cardiology, Tours, France (S.C., O.B., D.B.)
| | - Martine Gilard
- Brest University Hospital, Department of Cardiology, France (R.D., M.G.)
| | - Alain Cribier
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| | - Thierry Lefevre
- Institut Hospitalier Jacques Cartier, Ramsay Générale de Santé, Department of Cardiology, Massy, France (B.C., T.H., T.L.)
| | - Hélène Eltchaninoff
- Normandie Univ, UNIROUEN, INSERM U1096, Rouen University Hospital, Department of Cardiology, FHU REMOD-VHF, France (E.D., A.S., C.T., P.Y.L., G.A., A.C., H.E.)
| |
Collapse
|
38
|
Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2020; 2020:9163085. [PMID: 32454886 PMCID: PMC7219000 DOI: 10.1155/2020/9163085] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 01/25/2020] [Accepted: 01/30/2020] [Indexed: 01/14/2023]
Abstract
This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
Collapse
|
39
|
Lee JH, Rygg AD, Kolahdouz EM, Rossi S, Retta SM, Duraiswamy N, Scotten LN, Craven BA, Griffith BE. Fluid-Structure Interaction Models of Bioprosthetic Heart Valve Dynamics in an Experimental Pulse Duplicator. Ann Biomed Eng 2020; 48:1475-1490. [PMID: 32034607 PMCID: PMC7154025 DOI: 10.1007/s10439-020-02466-4] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 12/18/2019] [Indexed: 12/15/2022]
Abstract
Computer modeling and simulation is a powerful tool for assessing the performance of medical devices such as bioprosthetic heart valves (BHVs) that promises to accelerate device design and regulation. This study describes work to develop dynamic computer models of BHVs in the aortic test section of an experimental pulse-duplicator platform that is used in academia, industry, and regulatory agencies to assess BHV performance. These computational models are based on a hyperelastic finite element extension of the immersed boundary method for fluid-structure interaction (FSI). We focus on porcine tissue and bovine pericardial BHVs, which are commonly used in surgical valve replacement. We compare our numerical simulations to experimental data from two similar pulse duplicators, including a commercial ViVitro system and a custom platform related to the ViVitro pulse duplicator. Excellent agreement is demonstrated between the computational and experimental results for bulk flow rates, pressures, valve open areas, and the timing of valve opening and closure in conditions commonly used to assess BHV performance. In addition, reasonable agreement is demonstrated for quantitative measures of leaflet kinematics under these same conditions. This work represents a step towards the experimental validation of this FSI modeling platform for evaluating BHVs.
Collapse
Affiliation(s)
- Jae H Lee
- Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
| | - Alex D Rygg
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, USA
| | - Ebrahim M Kolahdouz
- Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, USA
| | - Simone Rossi
- Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
| | - Stephen M Retta
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, USA
| | - Nandini Duraiswamy
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, USA
| | | | - Brent A Craven
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, USA
| | - Boyce E Griffith
- Departments of Mathematics, Applied Physical Sciences, and Biomedical Engineering, University of North Carolina, Chapel Hill, NC, USA.
- Carolina Center for Interdisciplinary Applied Mathematics, University of North Carolina, Chapel Hill, NC, USA.
- Computational Medicine Program, University of North Carolina, Chapel Hill, NC, USA.
- McAllister Heart Institute, University of North Carolina, Chapel Hill, NC, USA.
| |
Collapse
|
40
|
Abbasi M, Azadani AN. A geometry optimization framework for transcatheter heart valve leaflet design. J Mech Behav Biomed Mater 2020; 102:103491. [DOI: 10.1016/j.jmbbm.2019.103491] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 09/06/2019] [Accepted: 10/10/2019] [Indexed: 10/25/2022]
|
41
|
Travaglino S, Murdock K, Tran A, Martin C, Liang L, Wang Y, Sun W. Computational Optimization Study of Transcatheter Aortic Valve Leaflet Design Using Porcine and Bovine Leaflets. J Biomech Eng 2020; 142:011007. [PMID: 31314886 DOI: 10.1115/1.4044244] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Indexed: 07/25/2024]
Abstract
In this study, a Bayesian optimization (BO) based computational framework is developed to investigate the design of transcatheter aortic valve (TAV) leaflets and to optimize leaflet geometry such that its peak stress under the blood pressure of 120 mmHg is reduced. A generic TAV model is parametrized by mathematical equations describing its 2D shape and its 3D stent-leaflet assembly line. Material properties previously obtained for bovine pericardium (BP) and porcine pericardium (PP) via a combination of flexural and biaxial tensile testing were incorporated into the finite element (FE) model of TAV. A BO approach was employed to investigate about 1000 leaflet designs for each material under the nominal circular deployment and physiological loading conditions. The optimal parameter values of the TAV model were obtained, corresponding to leaflet shapes that can reduce the peak stress by 16.7% in BP and 18.0% in PP, compared with that from the initial generic TAV model. Furthermore, it was observed that while peak stresses tend to concentrate near the stent-leaflet attachment edge, optimized geometries benefit from more uniform stress distributions in the leaflet circumferential direction. Our analysis also showed that increasing leaflet contact area redistributes peak stresses to the belly region contributing to peak stress reduction. The results from this study may inspire new TAV designs that can have better durability.
Collapse
Affiliation(s)
- Stefano Travaglino
- Tissue Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, GA, 30313-2412
| | - Kyle Murdock
- Tissue Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, GA, 30313-2412
| | - Anh Tran
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405
| | - Caitlin Martin
- Tissue Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, GA, 30313-2412
| | - Liang Liang
- Department of Computer Science, University of Miami, Coral Gables, FL, 33124
| | - Yan Wang
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405
| | - Wei Sun
- Tissue Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Technology Enterprise Park, Room 206 387 Technology Circle, Atlanta, GA 30313-2412
| |
Collapse
|
42
|
Bidar E, Folliguet T, Kluin J, Muneretto C, Parolari A, Barili F, Suwalski P, Bonaros N, Punjabi P, Sadaba R, De Bonis M, Al-Attar N, Obadia JF, Czerny M, Shrestha M, Zegdi R, Natour E, Lorusso R. Postimplant biological aortic prosthesis degeneration: challenges in transcatheter valve implants. Eur J Cardiothorac Surg 2019; 55:191-200. [PMID: 30541101 DOI: 10.1093/ejcts/ezy391] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 10/15/2018] [Indexed: 12/29/2022] Open
Abstract
Surgical aortic valve replacement (SAVR) is highly effective and can be achieved with relatively low risk in patients with severe aortic stenosis. Bioprostheses have been used most frequently during the past 60 years. However, the function of biological valves usually declines after 10-15 years from implant when structural valve degeneration occurs often mandating a reoperation once valve dysfunction becomes haemodynamically significant. Known for many years by surgeons and cardiologists taking care of patients with SAVR, the issue of postimplant structural valve degeneration has been recently highlighted also in patients with transcatheter aortic valve implant (TAVI). There is growing concern that TAVI valves exhibit structural valve degeneration due to inherent challenges of the deployment mode. The impact on postimplant degeneration of TAVI valves compared to SAVR has still to be understood and defined. Based on the ongoing process of expanding TAVI indications, several potential shortcomings and caveats, learned during the last 60 years of SAVR experience, should be taken into consideration to refine this technique.
Collapse
Affiliation(s)
- Elham Bidar
- Department of Cardio-Thoracic Surgery, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Thierry Folliguet
- Centre Hospitalo-Universitaire Brabois ILCV, Hôpital Henri Mondor, Division of Cardio Thoracic Surgery and Transplantation, Université Paris 12 UPEC, France
| | - Jolanda Kluin
- Department of Cardio-Thoracic Surgery, Academic Medical Center, Amsterdam, Netherlands
| | - Claudio Muneretto
- Cardiac Surgery Unit, University of Brescia Medical School, Brescia, Italy
| | - Alessandro Parolari
- Cardiac Surgery and Translational Research Units, IRCCS, Policlinico S. Donato, University of Milan, Milan, Italy
| | - Fabio Barili
- Department of Cardiac Surgery, S. Croce Hospital, Cuneo, Italy
| | - Piotr Suwalski
- Department of Cardiac Surgery, Central Clinical Hospital of the Ministry of Interior and Administration, Centre of Postgraduate Medical Education, Warsaw, Poland
| | - Nikolaos Bonaros
- Department of Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Prakash Punjabi
- Department of Cardio-Thoracic Surgery, Imperial College Healthcare NHS Trust, Imperial College School of Medicine, London, UK
| | - Rafa Sadaba
- Department of Cardiac Surgery, Hospital de Navarra, Pamplona, Spain
| | - Michele De Bonis
- Department of Cardiac Surgery, S. Raffaele University Hospital, Milan, Italy
| | - Nawwar Al-Attar
- Department of Cardiac Surgery, Golden Jubilee National Hospital, Glasgow, UK
| | - Jean Francois Obadia
- Department of Cardio-Thoracic Surgery, Hôpital Cardiothoracique Louis Pradel, Lyon, France
| | - Martin Czerny
- Department of Cardio-Vascular Surgery, University Hospital Freiburg, Freiburg, Germany
| | - Malakh Shrestha
- Department of Cardio-Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Rachid Zegdi
- Hôpital Européen Georges Pompidou, Paris, France
| | - Ehsan Natour
- Department of Cardio-Thoracic Surgery, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Roberto Lorusso
- Department of Cardio-Thoracic Surgery, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
43
|
Boukhris M, Forcillo J, Potvin J, Gobeil JF, Noiseux N, Stevens LM, Hillani A, Masson JB. Evolving Role of Transcatheter Valve Replacement for the Treatment of Severe Aortic Stenosis. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM 2019. [DOI: 10.1080/24748706.2019.1692397] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Marouane Boukhris
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Jessica Forcillo
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Jeannot Potvin
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Jean-François Gobeil
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Nicolas Noiseux
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Louis-Mathieu Stevens
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Ali Hillani
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| | - Jean-Bernard Masson
- From Divisions of Cardiology and Cardiac Surgery, Centre Hospitalier de l’Université de Montréal (CHUM), Québec, Canada
| |
Collapse
|
44
|
Noble C, Maxson EL, Lerman A, Young MD. Mechanical and finite element evaluation of a bioprinted scaffold following recellularization in a rat subcutaneous model. J Mech Behav Biomed Mater 2019; 102:103519. [PMID: 31879268 DOI: 10.1016/j.jmbbm.2019.103519] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 10/01/2019] [Accepted: 11/01/2019] [Indexed: 12/23/2022]
Abstract
Tissue engineered heart valves (TEHV) provide several advantages over currently available aortic heart valve replacements. Bioprinting provides a patient-specific means of developing a TEHV scaffold from imaging data, and the capability to embed the patient's own cells within the scaffold. In this work we investigated the remodeling capacity of a collagen-based bio-ink by implanting bioprinted disks in a rat subcutaneous model for 2, 4 and 12 weeks and evaluating the mechanical response using biaxial testing and subsequent finite element (FE) modeling. Samples explanted after 2 and 4 weeks showed inferior mechanical properties compared to native tissues while 12 week explants showed a mechanical response of similar magnitude but did not demonstrate the anisotropy present in native tissues. In the FE analysis, the model utilizing mechanical properties from samples explanted after 12 weeks showed the closest mechanical behavior to the native tissues. However, in diastole native tissues showed higher stress in the leaflet belly and lower strain at the commissures compared to 12 week explants, likely due to the anisotropy present in the native tissues. Thus, either further remodeling is required in situ in the aortic valve position or by in vitro preconditioning in an environment such as a bioreactor. Regardless, these results demonstrate the utility of FE analysis to optimize bioprinting process parameters for the most favorable in vivo mechanical performance.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Eva L Maxson
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Melissa D Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
45
|
Liang L, Sun B. A Proof of Concept Study of Using Machine-Learning in Artificial Aortic Valve Design: From Leaflet Design to Stress Analysis. Bioengineering (Basel) 2019; 6:bioengineering6040104. [PMID: 31717333 PMCID: PMC6955850 DOI: 10.3390/bioengineering6040104] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 10/31/2019] [Accepted: 11/04/2019] [Indexed: 12/02/2022] Open
Abstract
Artificial heart valves, used to replace diseased human heart valves, are life-saving medical devices. Currently, at the device development stage, new artificial valves are primarily assessed through time-consuming and expensive benchtop tests or animal implantation studies. Computational stress analysis using the finite element (FE) method presents an attractive alternative to physical testing. However, FE computational analysis requires a complex process of numeric modeling and simulation, as well as in-depth engineering expertise. In this proof of concept study, our objective was to develop machine learning (ML) techniques that can estimate the stress and deformation of a transcatheter aortic valve (TAV) from a given set of TAV leaflet design parameters. Two deep neural networks were developed and compared: the autoencoder-based ML-models and the direct ML-models. The ML-models were evaluated through Monte Carlo cross validation. From the results, both proposed deep neural networks could accurately estimate the deformed geometry of the TAV leaflets and the associated stress distributions within a second, with the direct ML-models (ML-model-d) having slightly larger errors. In conclusion, although this is a proof-of-concept study, the proposed ML approaches have demonstrated great potential to serve as a fast and reliable tool for future TAV design.
Collapse
Affiliation(s)
- Liang Liang
- Department of Computer Science, University of Miami, Coral Gables, FL 33146, USA
- Correspondence:
| | - Bill Sun
- Walton High School, Marietta, GA 30062, USA;
| |
Collapse
|
46
|
Capodanno D, Søndergaard L, Tamburino C. Durability of transcatheter bioprosthetic aortic valves: the story so far. EUROINTERVENTION 2019; 15:846-849. [DOI: 10.4244/eijv15i10a160] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
47
|
Luraghi G, Migliavacca F, García-González A, Chiastra C, Rossi A, Cao D, Stefanini G, Rodriguez Matas JF. On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach. Cardiovasc Eng Technol 2019; 10:437-455. [PMID: 31309527 DOI: 10.1007/s13239-019-00427-0] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 07/04/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE Transcatheter aortic valve replacement (TAVR) is a minimally invasive treatment for high-risk patients with aortic diseases. Despite its increasing use, many influential factors are still to be understood and require continuous investigation. The best numerical approach capable of reproducing both the valves mechanics and the hemodynamics is the fluid-structure interaction (FSI) modeling. The aim of this work is the development of a patient-specific FSI methodology able to model the implantation phase as well as the valve working conditions during cardiac cycles. METHODS The patient-specific domain, which included the aortic root, native valve and calcifications, was reconstructed from CT images, while the CAD model of the device, metallic frame and pericardium, was drawn from literature data. Ventricular and aortic pressure waveforms, derived from the patient's data, were used as boundary conditions. The proposed method was applied to two real clinical cases, which presented different outcomes in terms of paravalvular leakage (PVL), the main complication after TAVR. RESULTS The results confirmed the clinical prognosis of mild and moderate PVL with coherent values of regurgitant volume and effective regurgitant orifice area. Moreover, the final release configuration of the device and the velocity field were compared with postoperative CT scans and Doppler traces showing a good qualitative and quantitative matching. CONCLUSION In conclusion, the development of realistic and accurate FSI patient-specific models can be used as a support for clinical decisions before the implantation.
Collapse
Affiliation(s)
- Giulia Luraghi
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Alberto García-González
- Laboratori de Càlcul Numèric (LaCàN), E.T.S. de Ingenieros de Caminos, Canales y Puertos, Universitat Politècnica de Catalunya (UPC), Jordi Girona 1-3, 08034, Barcelona, Spain
| | - Claudio Chiastra
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.,PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Turin, Italy
| | - Alexia Rossi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Davide Cao
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Giulio Stefanini
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Jose Felix Rodriguez Matas
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| |
Collapse
|
48
|
Caballero A, Mao W, McKay R, Sun W. The impact of balloon-expandable transcatheter aortic valve replacement on concomitant mitral regurgitation: a comprehensive computational analysis. J R Soc Interface 2019; 16:20190355. [PMID: 31409236 DOI: 10.1098/rsif.2019.0355] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The aortic and mitral valves function in a reciprocal interdependent fashion. However, the impact of transcatheter aortic valve replacement (TAVR) on the aortic-mitral continuity and severity of mitral regurgitation (MR) are poorly understood. In this study, a comprehensive engineering analysis was performed to investigate the impact of TAVR on MR severity and left heart dynamics in a retrospective patient case who harbours bicuspid aortic valve stenosis and concomitant functional MR. The TAVR procedure was computer simulated using a balloon-expandable valve, and the impact of three implantation heights on aortic-mitral coupling, MR severity and device performance were analysed. The accuracy and predictability of the computer modelling framework were validated with pre- and post-operative echo data. The highest deployment model resulted in higher stresses in the native leaflets, contact radial force and stent recoil, while the midway implantation model gave better haemodynamic performance and MR reduction in this patient case. Although the regurgitant volume decreased (less than 10%) for the three deployment configurations, no significant differences in MR severity improvement and mitral leaflet tethering were found. Acute improvement in MR was (i) due to the mechanical compression of the stent against the aortic-mitral curtain, (ii) due to an immediate drop in the ventricular pressure and transmitral pressure gradient. Albeit a single real clinical case, it is our hope that such detailed engineering computational analysis could shed light on the underlying biomechanical mechanisms of TAVR impact on MR.
Collapse
Affiliation(s)
- Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Raymond McKay
- Division of Cardiology, The Hartford Hospital, Hartford, CT, USA
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| |
Collapse
|
49
|
Dalgliesh AJ, Parvizi M, Noble C, Griffiths LG. Effect of cyclic deformation on xenogeneic heart valve biomaterials. PLoS One 2019; 14:e0214656. [PMID: 31194770 PMCID: PMC6563958 DOI: 10.1371/journal.pone.0214656] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Accepted: 03/18/2019] [Indexed: 11/19/2022] Open
Abstract
Glutaraldehyde-fixed bovine pericardium is currently the most popular biomaterial utilized in the creation of bioprosthetic heart valves. However, recent studies indicate that glutaraldehyde fixation results in calcification and structural valve deterioration, limiting the longevity of bioprosthetic heart valves. Additionally, glutaraldehyde fixation renders the tissue incompatible with constructive recipient cellular repopulation, remodeling and growth. Use of unfixed xenogeneic biomaterials devoid of antigenic burden has potential to overcome the limitations of current glutaraldehyde-fixed biomaterials. Heart valves undergo billion cycles of opening and closing throughout the patient’s lifetime. Therefore, understanding the response of unfixed tissues to cyclic loading is crucial to these in a heart valve leaflet configuration. In this manuscript we quantify the effect of cyclic deformation on cycle dependent strain, structural, compositional and mechanical properties of fixed and unfixed tissues. Glutaraldehyde-fixed bovine pericardium underwent marked cyclic dependent strain, resulting from significant changes in structure, composition and mechanical function of the material. Conversely, unfixed bovine pericardium underwent minimal strain and maintained its structure, composition and mechanical integrity. This manuscript demonstrates that unfixed bovine pericardium can withstand cyclic deformations equivalent to 6 months of in vivo heart valve leaflet performance.
Collapse
Affiliation(s)
- Ailsa J. Dalgliesh
- Department of Veterinary Medicine: Medicine and Epidemiology, University of California, Davis, Davis, CA, United States of America
- Department of Cardiovascular Diseases, Mayo Clinic, SW, Rochester, MN, United States of America
| | - Mojtaba Parvizi
- Department of Cardiovascular Diseases, Mayo Clinic, SW, Rochester, MN, United States of America
| | - Christopher Noble
- Department of Cardiovascular Diseases, Mayo Clinic, SW, Rochester, MN, United States of America
| | - Leigh G. Griffiths
- Department of Cardiovascular Diseases, Mayo Clinic, SW, Rochester, MN, United States of America
- * E-mail:
| |
Collapse
|
50
|
Hwang IC, Hayashida K, Kim HS. Current Key Issues in Transcatheter Aortic Valve Replacement Undergoing a Paradigm Shift. Circ J 2019; 83:952-962. [PMID: 30956265 DOI: 10.1253/circj.cj-19-0096] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
As a new technology in the management of valvular heart disease, transcatheter aortic valve replacement (TAVR) has drawn much attention since its emergence. To date, numerous studies have investigated the safety and efficacy of TAVR in patients of various risk profiles with severe aortic stenosis (AS) and demonstrated comparable or superior outcomes of TAVR when compared with surgical aortic valve replacement (SAVR). The favorable outcomes of TAVR in inoperable patients, as well as in high- and intermediate-risk patients, are endorsed in current guidelines, and trials of low-risk patients have shown non-inferior or even superior results of TAVR than for SAVR, suggesting that the clinical indications of TAVR can be expanded to low-risk patients. Moreover, a therapeutic role of TAVR has been suggested in various aortic valve (AV) diseases, such as bicuspid AV, moderate AS with heart failure, aortic regurgitation, and bioprosthetic valve failure. In this review, we summarize the current issues of TAVR in various patient populations and discuss the expanding clinical indications of TAVR, which are driving a major paradigm shift in the management of AV disease.
Collapse
Affiliation(s)
- In-Chang Hwang
- Division of Cardiology, Department of Internal Medicine, Seoul National University Bundang Hospital.,Cardiovascular Center, Department of Internal Medicine, Seoul National University Hospital
| | | | - Hyo-Soo Kim
- Cardiovascular Center, Department of Internal Medicine, Seoul National University Hospital
| |
Collapse
|