1
|
He A, Wilkins B, Lan NSR, Othman F, Sehly A, Bhat V, Jaltotage B, Dwivedi G, Leipsic J, Ihdayhid AR. Cardiac computed tomography post-transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr 2024; 18:319-326. [PMID: 38782668 DOI: 10.1016/j.jcct.2024.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/25/2024] [Accepted: 04/25/2024] [Indexed: 05/25/2024]
Abstract
Transcatheter aortic valve replacement (TAVR) is performed to treat aortic stenosis and is increasingly being utilised in the low-to-intermediate-risk population. Currently, attention has shifted towards long-term outcomes, complications and lifelong maintenance of the bioprosthesis. Some patients with TAVR in-situ may develop significant coronary artery disease over time requiring invasive coronary angiography, which may be problematic with the TAVR bioprosthesis in close proximity to the coronary ostia. In addition, younger patients may require a second transcatheter heart valve (THV) to 'replace' their in-situ THV because of gradual structural valve degeneration. Implantation of a second THV carries a risk of coronary obstruction, thereby requiring comprehensive pre-procedural planning. Unlike in the pre-TAVR period, cardiac CT angiography in the post-TAVR period is not well established. However, post-TAVR cardiac CT is being increasingly utilised to evaluate mechanisms for structural valve degeneration and complications, including leaflet thrombosis. Post-TAVR CT is also expected to have a significant role in risk-stratifying and planning future invasive procedures including coronary angiography and valve-in-valve interventions. Overall, there is emerging evidence for post-TAVR CT to be eventually incorporated into long-term TAVR monitoring and lifelong planning.
Collapse
Affiliation(s)
- Albert He
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia; Department of Cardiology, Dunedin Public Hospital, Dunedin, New Zealand
| | - Ben Wilkins
- Department of Cardiology, Dunedin Public Hospital, Dunedin, New Zealand
| | - Nick S R Lan
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia; Harry Perkins Institute of Medical Research, Perth, Australia; Medical School, University of Western Australia, Perth, Australia
| | - Farrah Othman
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia
| | - Amro Sehly
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia
| | - Vikas Bhat
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia
| | | | - Girish Dwivedi
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia; Harry Perkins Institute of Medical Research, Perth, Australia; Medical School, University of Western Australia, Perth, Australia
| | - Jonathon Leipsic
- Department of Radiology, St Paul's Hospital, University of British Columbia, Vancouver, Canada
| | - Abdul Rahman Ihdayhid
- Department of Cardiology, Fiona Stanley Hospital, Perth, Australia; Harry Perkins Institute of Medical Research, Perth, Australia; Medical School, Curtin University, Perth, Australia.
| |
Collapse
|
2
|
Pontone G, Maragna R. TAVI: What Happens Behind the Stage? JACC Cardiovasc Imaging 2024; 17:408-410. [PMID: 37943234 DOI: 10.1016/j.jcmg.2023.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 09/26/2023] [Indexed: 11/10/2023]
Affiliation(s)
- Gianluca Pontone
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
| | - Riccardo Maragna
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy
| |
Collapse
|
3
|
Chrysostomidis G, Apostolos A, Papanikolaou A, Konstantinou K, Tsigkas G, Koliopoulou A, Chamogeorgakis T. The Application of Precision Medicine in Structural Heart Diseases: A Step towards the Future. J Pers Med 2024; 14:375. [PMID: 38673001 PMCID: PMC11051532 DOI: 10.3390/jpm14040375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/20/2024] [Accepted: 03/23/2024] [Indexed: 04/28/2024] Open
Abstract
The personalized applications of 3D printing in interventional cardiology and cardiac surgery represent a transformative paradigm in the management of structural heart diseases. This review underscores the pivotal role of 3D printing in enhancing procedural precision, from preoperative planning to procedural simulation, particularly in valvular heart diseases, such as aortic stenosis and mitral regurgitation. The ability to create patient-specific models contributes significantly to predicting and preventing complications like paravalvular leakage, ensuring optimal device selection, and improving outcomes. Additionally, 3D printing extends its impact beyond valvular diseases to tricuspid regurgitation and non-valvular structural heart conditions. The comprehensive synthesis of the existing literature presented here emphasizes the promising trajectory of individualized approaches facilitated by 3D printing, promising a future where tailored interventions based on precise anatomical considerations become standard practice in cardiovascular care.
Collapse
Affiliation(s)
- Grigorios Chrysostomidis
- Second Department of Adult Cardiac Surgery—Heart and Lung Transplantation, Onassis Cardiac Surgery Center, 176 74 Athens, Greece; (G.C.); (A.K.); (T.C.)
| | - Anastasios Apostolos
- First Department of Cardiology, National and Kapodistrian University of Athens, Hippocration General Hospital, 115 27 Athens, Greece;
| | - Amalia Papanikolaou
- First Department of Cardiology, National and Kapodistrian University of Athens, Hippocration General Hospital, 115 27 Athens, Greece;
| | - Konstantinos Konstantinou
- Royal Brompton and Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London 26504, UK;
| | - Grigorios Tsigkas
- Department of Cardiology, University Hospital of Patras, 265 04 Patras, Greece;
| | - Antigoni Koliopoulou
- Second Department of Adult Cardiac Surgery—Heart and Lung Transplantation, Onassis Cardiac Surgery Center, 176 74 Athens, Greece; (G.C.); (A.K.); (T.C.)
| | - Themistokles Chamogeorgakis
- Second Department of Adult Cardiac Surgery—Heart and Lung Transplantation, Onassis Cardiac Surgery Center, 176 74 Athens, Greece; (G.C.); (A.K.); (T.C.)
| |
Collapse
|
4
|
Urzua Fresno CM, Ocazionez D, Groves DW, Vargas D. Computed Tomography of Transcatheter Aortic Valve Replacement-Related Complications. Semin Roentgenol 2024; 59:112-120. [PMID: 38388090 DOI: 10.1053/j.ro.2023.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 11/22/2023] [Accepted: 11/25/2023] [Indexed: 02/24/2024]
Affiliation(s)
| | - Daniel Ocazionez
- Department of Diagnostic and Interventional Imaging, The University of Texas Health Science Center at Houston-McGovern Medical School, Houston, TX
| | - Daniel W Groves
- Departments of Medicine and Radiology, University of Colorado, Aurora, CO
| | - Daniel Vargas
- Department of Radiology, University of Colorado, Aurora, CO.
| |
Collapse
|
5
|
Yang YX, Liu XM, Fu Y, Li C, Wang HJ, Xu L, Xia K, Zhang ZY, Zhong JC, Chen ML, Su PX, Wang LF. Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis. Int J Surg 2023; 109:2414-2426. [PMID: 37161443 PMCID: PMC10442113 DOI: 10.1097/js9.0000000000000456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 05/01/2023] [Indexed: 05/11/2023]
Abstract
BACKGROUND Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim of the study was to compare the efficiency and safety of different new-generation TAVI devices for patients with aortic stenosis. MATERIALS AND METHODS A comprehensive search of PubMed, Embase and Web of Science from their inception to 1 February 2022. Randomized clinical trials and observational studies that compared two or more different TAVI devices were enroled. Pairwise meta-analysis and frequentist network meta-analysis were conducted to pool the outcome estimates of interest. RESULTS A total of 79 studies were finally included. According to the surface under the cumulative ranking, the top two ranked valves for lower rates of events were as follows: direct flow medical (DFM) (4.6%) and Lotus (48.8%) for lower rate of device success; Sapien 3 (16.8%) and DFM (19.7%) for lower mortality; DFM (8.6%) and Sapien 3 (25.5%) for lower rates of stroke; Evolut (27.6%) and DFM (35.8%) for lower rates of major and life-threatening bleeding; Portico (22.6%) and Sapien 3 (41.9%) for lower rates of acute kidney injury; Acurate (8.6%) and DFM (13.2%) for lower rates of permanent pacemaker implantation; Lotus (0.3%) and Sapien 3 (22.7%) for lower rates of paravalvular leak; Evolut (1.4%) and Portico (29.1%) for lower rates of mean aortic valve gradients. CONCLUSIONS The findings of the present study suggested that the device success rates were comparable among these new-generation valves except for DFM. After excluding DFM, Sapien 3 might be the best effective for decreased mortality and stroke; Lotus might be the best effective for decreased paravalvular leak; Evolut might be the best effective for decreased major and life-threatening bleeding and mean aortic valve gradients; Acurate and Portico might be the best effective for decreased permanent pacemaker implantation and acute kidney injury, respectively.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Pi-Xiong Su
- Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | | |
Collapse
|
6
|
Sá MP, Jacquemyn X, Van den Eynde J, Tasoudis P, Dokollari A, Torregrossa G, Sicouri S, Clavel MA, Pibarot P, Ramlawi B. Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement: Meta-Analysis of Kaplan-Meier-Derived Individual Patient Data. JACC Cardiovasc Imaging 2023; 16:298-310. [PMID: 36648055 DOI: 10.1016/j.jcmg.2022.07.013] [Citation(s) in RCA: 34] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 06/07/2022] [Accepted: 07/15/2022] [Indexed: 01/18/2023]
Abstract
BACKGROUND It remains controversial whether prosthesis-patient mismatch (PPM) (in general considered moderate if indexed effective orifice area is 0.65-0.85 cm2/m2 and severe when <0.65 cm2/m2) affects the outcomes after transcatheter aortic valve replacement (TAVR). OBJECTIVES The purpose of this study is to evaluate the time-varying effects and association of PPM with the risk of overall mortality. METHODS Study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of studies published by December 30, 2021. RESULTS In total, 23 studies met our eligibility criteria and included a total of 81,969 patients included in the Kaplan-Meier curves (19,612 with PPM and 62,357 without PPM). Patients with moderate/severe PPM had a significantly higher risk of mortality compared with those without PPM (HR: 1.09 [95% CI: 1.04-1.14]; P < 0.001). In the first 30 months after the procedure, mortality rates were significantly higher in the moderate/severe PPM group (HR: 1.1 [95% CI: 1.05-1.16]; P < 0.001). In contrast, the landmark analysis beyond 30 months yielded a reversal of the HR (0.83 [95% CI: 0.68-1.01]; P = 0.064), but without statistical significance. In the sensitivity analysis, although the authors observed that severe PPM showed higher risk of mortality in comparison with no PPM (HR: 1.25 [95% CI: 1.16-1.36]; P < 0.001), they did not observe a statistically significant difference for mortality between moderate PPM and no PPM (HR: 1.03 [95% CI: 0.96-1.10]; P = 0.398). CONCLUSIONS Severe PPM, but not moderate PPM, was associated with higher risk of mortality following TAVR. These results provide support to implementation of preventive strategies to avoid severe PPM following TAVR.
Collapse
Affiliation(s)
- Michel Pompeu Sá
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA; Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.
| | - Xander Jacquemyn
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | | | - Panagiotis Tasoudis
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Aleksander Dokollari
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Gianluca Torregrossa
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA; Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Serge Sicouri
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Marie-Annick Clavel
- Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec City, Québec, Canada; Department of Medicine, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Philippe Pibarot
- Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec City, Québec, Canada; Department of Medicine, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Basel Ramlawi
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA; Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| |
Collapse
|
7
|
Okuno T, Tomii D, Lanz J, Heg D, Praz F, Stortecky S, Reineke D, Windecker S, Pilgrim T. 5-Year Outcomes With Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients With Small Annuli. JACC Cardiovasc Interv 2023; 16:429-440. [PMID: 36858662 DOI: 10.1016/j.jcin.2022.11.032] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/15/2022] [Accepted: 11/23/2022] [Indexed: 03/02/2023]
Abstract
BACKGROUND Self-expanding transcatheter heart valves (THVs) are associated with better echocardiographic hemodynamic performance than balloon-expandable THVs and are considered preferable in patients with small annuli. OBJECTIVES This study sought to compare 5-year outcomes between self-expanding vs balloon-expandable THVs in severe aortic stenosis (AS) patients with small annuli. METHODS Consecutive severe AS patients with an aortic valve annulus area <430 mm2 who underwent transcatheter aortic valve replacement (TAVR) with either the CoreValve Evolut (Medtronic) or SAPIEN (Edwards Lifesciences) THV between 2012 and 2021 were enrolled from the Bern TAVI registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups. RESULTS A total of 723 patients were included, and propensity score matching resulted in 171 pairs. Technical success was achieved in over 85% of both groups with no significant difference. Self-expanding THVs were associated with a lower transvalvular gradient (8.0 ± 4.8 mm Hg vs 12.5 ± 4.5 mm Hg; P < 0.001), a larger effective orifice area (1.81 ± 0.46 cm2 vs 1.49 ± 0.42 cm2; P < 0.001), and a lower incidence of prosthesis-patient mismatch (19.7% vs 51.8%; P < 0.001) than balloon-expandable THVs. At 5 years, there were no significant differences in mortality (50.4% vs 39.6%; P = 0.269) between groups. Disabling stroke occurred more frequently in patients with a self-expanding THV than those with a balloon-expandable THV (6.6% vs 0.6%; P = 0.030). Similar results were obtained using inverse probability of treatment weighting in the Bern TAVI registry and the nationwide Swiss TAVI registry. CONCLUSIONS The echocardiographic hemodynamic advantage of self-expanding THVs was not associated with better clinical outcomes compared with balloon-expandable THVs up to 5 years in patients with small annuli. (Swiss TAVI Registry; NCT01368250).
Collapse
Affiliation(s)
- Taishi Okuno
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. https://twitter.com/TaishiOkuno
| | - Daijiro Tomii
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. https://twitter.com/DaijiroTomii
| | - Jonas Lanz
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland
| | - Dik Heg
- Clinical Trials Unit Bern, University of Bern, Bern, Switzerland
| | - Fabien Praz
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. https://twitter.com/FabienPraz
| | - Stefan Stortecky
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. https://twitter.com/StefanStortecky
| | - David Reineke
- Department of Cardiac Surgery, Inselspital, University of Bern, Bern, Switzerland. https://twitter.com/DReineke76
| | - Stephan Windecker
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland.
| |
Collapse
|
8
|
Core Lab Adjudication of the ACURATE neo2 Hemodynamic Performance Using Computed-Tomography-Corrected Left Ventricular Outflow Tract Area. J Clin Med 2022; 11:jcm11206103. [PMID: 36294424 PMCID: PMC9605387 DOI: 10.3390/jcm11206103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 09/28/2022] [Accepted: 10/13/2022] [Indexed: 11/23/2022] Open
Abstract
(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: −55.15, −36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = −0.642 (95%CrI of differences: −0.85, −0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = −7.29 (95% CrI: −14.45, −0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.
Collapse
|
9
|
Miyasaka M, Tada N. Prosthesis-patient mismatch after transcatheter aortic valve implantation. Cardiovasc Interv Ther 2022; 37:615-625. [PMID: 35708855 DOI: 10.1007/s12928-022-00865-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 05/08/2022] [Indexed: 01/22/2023]
Abstract
Prosthesis-patient mismatch (PPM), first described in 1978, occurs when a prosthetic valve functions normally, but has an effective orifice area that is too small relative to the patient's body surface area. It results in residual left ventricular afterload and higher transvalvular pressure gradient, which has been considered to impair prognosis. PPM following surgical aortic replacement is reportedly associated with worse clinical outcomes, such as high mortality. However, the impact of PPM on clinical outcomes after transcatheter aortic valve implantation (TAVI) remains unclear. There is conflicting evidence on the impact of PPM following TAVI due to differences across studies in terms of follow-up period, methods, patient populations, and type of bioprosthetic valve. The present review summarizes the most recent evidence on PPM after TAVI.
Collapse
Affiliation(s)
- Masaki Miyasaka
- Department of Laboratory Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, Japan. .,Cardiovascular Center, Sendai Kosei Hospital, Miyagi, Japan.
| | - Norio Tada
- Cardiovascular Center, Sendai Kosei Hospital, Miyagi, Japan
| | | |
Collapse
|
10
|
Kolossváry M, Reid AB, Baggiano A, Nagpal P, Canan A, Al'Aref SJ, Andreini D, Cavalcante JL, de Cecco CN, Chelliah A, Chen MY, Choi AD, Dey D, Fairbairn T, Ferencik M, Gransar H, Hecht H, Leipsic J, Lu MT, Marwan M, Maurovich-Horvat P, Ng MY, Nicol ED, Pontone G, Vliegenthart R, Whelton SP, Williams MC, Arbab-Zadeh A, Farooqi KM, Weir-McCall J, Feuchtner G, Villines TC. The Journal of cardiovascular computed tomography: A year in review 2021. J Cardiovasc Comput Tomogr 2022; 16:266-276. [PMID: 35370125 DOI: 10.1016/j.jcct.2022.03.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
This review aims to summarize original articles published in the Journal of Cardiovascular Computed Tomography (JCCT) for the year 2021, focusing on those that had the most scientific and educational impact. The JCCT continues to expand; the number of submissions, published manuscripts, cited articles, article downloads, social media presence, and impact factor continues to increase. The articles selected by the Editorial Board of the JCCT in this review focus on coronary artery disease, coronary physiology, structural heart disease, and technical advances in cardiovascular CT. In addition, we highlight key consensus documents and guidelines published in the Journal in 2021. The Journal recognizes the tremendous work done by each author and reviewer this year - thank you.
Collapse
Affiliation(s)
- Márton Kolossváry
- Cardiovascular Imaging Research Center, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Anna B Reid
- University of Manchester NHS Foundation Trust, Manchester, UK
| | | | - Prashant Nagpal
- Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA
| | - Arzu Canan
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Subhi J Al'Aref
- Department of Medicine, Division of Cardiology. University of Arkansas for Medical Sciences (UAMS), Little Rock, AR, USA
| | - Daniele Andreini
- Centro Cardiologico Monzino IRCCS, Milan, Italy; Department of Biomedical and Clinical Sciences "Luigi Sacco", University of Milan, Milan, Italy
| | - João L Cavalcante
- Minneapolis Heart Institute at Abbott Northwestern Hospital, Minneapolis, MN, USA
| | - Carlo N de Cecco
- Department of Radiology and Imaging Sciences, Division of Cardiothoracic Imaging, Emory University, Atlanta, GA, USA
| | - Anjali Chelliah
- Department of Pediatrics, Division of Cardiology, Goryeb Children's Hospital/Atlantic Health System, Morristown, NJ, USA; Department of Pediatrics, Division of Cardiology, Columbia University Irving Medical Center, New York, NY, USA
| | - Marcus Y Chen
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Andrew D Choi
- The George Washington University School of Medicine, Washington, DC, USA
| | - Damini Dey
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Timothy Fairbairn
- Liverpool Centre for Cardiovascular Science, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Heidi Gransar
- Department of Imaging, Cardiac Imaging Research, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Harvey Hecht
- Ican School of Medicine at Mount Sinai, Mount Sinai Morningside Medical Center, NYC, USA
| | - Jonathan Leipsic
- Department of Radiology and Medicine (Cardiology), University of British Columbia, Canada
| | - Michael T Lu
- Cardiovascular Imaging Research Center, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Mohamed Marwan
- Department of Cardiology, Friedrich-Alexander-Universität, Erlangen-Nürnberg, Germany
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Hungary; Medical Imaging Centre, Semmelweis University, Budapest, Hungary
| | - Ming-Yen Ng
- Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong SAR, China
| | - Edward D Nicol
- Departments of Cardiology and Radiology, Royal Brompton Hospital, London UK; School of Bioengineering and Imaging Sciences, Kings College, London, UK
| | | | - Rozemarijn Vliegenthart
- Department of Radiology, University of Groningen/University Medical Center Groningen, Groningen, the Netherlands
| | - Seamus P Whelton
- Johns Hopkins Ciccarone Center for the Prevention of Cardiovascular Disease, Baltimore, MD, USA
| | | | - Armin Arbab-Zadeh
- Department of Medicine/Division of Cardiology, Johns Hopkins University, Baltimore, MD, USA
| | - Kanwal M Farooqi
- Department of Pediatrics, Division of Cardiology, Columbia University Irving Medical Center, New York, NY, USA
| | | | - Gudrun Feuchtner
- Innsbruck Medical University, Dept. Radiology, Innsbruck, Austria
| | - Todd C Villines
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, VA, USA.
| |
Collapse
|
11
|
Ternacle J, Abbas AE, Pibarot P. Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement: Has It Become Obsolete? JACC Cardiovasc Interv 2021; 14:977-980. [PMID: 33958171 DOI: 10.1016/j.jcin.2021.03.039] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 03/17/2021] [Indexed: 11/19/2022]
Affiliation(s)
- Julien Ternacle
- Haut-Lévêque Cardiology Hospital, University Hospital of Bordeaux, Pessac, France
| | - Amr E Abbas
- Department of Cardiovascular Medicine, Beaumont Hospital Royal Oak, Royal Oak, Michigan, USA
| | - Philippe Pibarot
- Department of Cardiology, Institut Universitaire de Cardiologie et de Pneumologie de Québec/Québec Heart & Lung Institute, Laval University, Québec, Canada.
| |
Collapse
|