1
|
Niessen J, Nilsson JM, Peters K, Indulkar A, Borchardt T, Koziolek M, Lennernäs H, Dahlgren D, Hedeland M. Development and validation of LC-MS/MS methods for the pharmacokinetic assessment of the PROTACs bavdeglutamide (ARV-110) and vepdegestrant (ARV-471). J Pharm Biomed Anal 2024; 249:116348. [PMID: 38996751 DOI: 10.1016/j.jpba.2024.116348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/24/2024] [Accepted: 07/08/2024] [Indexed: 07/14/2024]
Abstract
Chemically induced, targeted protein degradation with proteolysis targeting chimeras (PROTACs) has shown to be a promising pharmacological strategy to circumvent the poor "druggability" of intracellular targets. However, the favorable pharmacology comes with complex molecular properties limiting the oral bioavailability of these drugs. To foster the translation of PROTACs into the clinics it is of high importance to establish sensitive bioanalytical methods that enable the assessment of absorption, bioavailability, and disposition of PROTACs after oral dosing. In this study, two highly sensitive LC-MS/MS methods (LLOQ = 0.5 ng/mL) were developed and validated for the quantification of bavdeglutamide (ARV-110) and vepdegestrant (ARV-471) in rat plasma. Plasma samples were processed by protein precipitation and separated on a C18 column over a gradient of acetonitrile and water with 0.1 % formic acid. Selected reaction monitoring in positive ESI mode was applied to quantify ARV-110 and ARV-471. Both methods showed linearity, accuracy, and precision as well as matrix effects and carry-over within the predefined acceptance criteria. High stability of the compounds in plasma was demonstrated at long-term storage for seven weeks at -20 °C, three freeze-thaw cycles, up to 20 min at room temperature, and as extracts in the autosampler. The plasma concentration-time curves after intravenous and intraduodenal bolus single-dose administrations in rats could be successfully quantified at clinically relevant doses per body weight. The highly sensitive bioanalytical assays presented in this work enable the application of a broad spectrum of in vivo studies to elucidate the oral absorption, bioavailability, and disposition of PROTACs.
Collapse
Affiliation(s)
- Janis Niessen
- Department of Pharmaceutical Biosciences, Translational Drug Discovery and Development, Uppsala University, Uppsala, Sweden
| | - Jenny M Nilsson
- Department of Medicinal Chemistry, Analytical Pharmaceutical Chemistry, Uppsala University, Uppsala, Sweden
| | - Karsten Peters
- Department of Pharmaceutical Biosciences, Translational Drug Discovery and Development, Uppsala University, Uppsala, Sweden
| | - Anura Indulkar
- AbbVie Research and Development, 1N Waukegan Road, North Chicago, IL, USA
| | - Thomas Borchardt
- AbbVie Research and Development, 1N Waukegan Road, North Chicago, IL, USA
| | - Mirko Koziolek
- Abbvie Deutschland GmbH & Co. KG, Small Molecule CMC Development, Knollstrasse, Ludwigshafen, Germany
| | - Hans Lennernäs
- Department of Pharmaceutical Biosciences, Translational Drug Discovery and Development, Uppsala University, Uppsala, Sweden
| | - David Dahlgren
- Department of Pharmaceutical Biosciences, Translational Drug Discovery and Development, Uppsala University, Uppsala, Sweden
| | - Mikael Hedeland
- Department of Medicinal Chemistry, Analytical Pharmaceutical Chemistry, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
2
|
More D, Khan N, Tekade RK, Sengupta P. An Update on Current Trend in Sample Preparation Automation in Bioanalysis: strategies, Challenges and Future Direction. Crit Rev Anal Chem 2024:1-25. [PMID: 38949910 DOI: 10.1080/10408347.2024.2362707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/03/2024]
Abstract
Automation in sample preparation improves accuracy, productivity, and precision in bioanalysis. Moreover, it reduces resource consumption for repetitive procedures. Automated sample analysis allows uninterrupted handling of large volumes of biological samples originating from preclinical and clinical studies. Automation significantly helps in management of complex testing methods where generation of large volumes of data is required for process monitoring. Compared to traditional sample preparation processes, automated procedures reduce associated expenses and manual error, facilitate laboratory transfers, enhance data quality, and better protect the health of analysts. Automated sample preparation techniques based on robotics potentially increase the throughput of bioanalytical laboratories. Robotic liquid handler, an automated sample preparation system built on a robotic technique ensures optimal laboratory output while saving expensive solvents, manpower, and time. Nowadays, most of the traditional extraction processes are being automated using several formats of online techniques. This review covered most of the automated sample preparation techniques reported till date, which accelerated and simplified the sample preparation procedure for bioanalytical sample analysis. This article critically analyzed different developmental aspects of automated sample preparation techniques based on robotics as well as conventional sample preparation methods that are accelerated using automated technologies.
Collapse
Affiliation(s)
- Dnyaneshwar More
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Opp. Airforce Station, Palaj, Gandhinagar 382355, Gujarat, India
| | - Nasir Khan
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Opp. Airforce Station, Palaj, Gandhinagar 382355, Gujarat, India
| | - Rakesh Kumar Tekade
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Opp. Airforce Station, Palaj, Gandhinagar 382355, Gujarat, India
| | - Pinaki Sengupta
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Opp. Airforce Station, Palaj, Gandhinagar 382355, Gujarat, India
| |
Collapse
|
3
|
Bertić M, Zimmer I, Andrés-Montaner D, Rosenkranz M, Kangasjärvi J, Schnitzler JP, Ghirardo A. Automatization of metabolite extraction for high-throughput metabolomics: case study on transgenic isoprene-emitting birch. TREE PHYSIOLOGY 2023; 43:1855-1869. [PMID: 37418159 DOI: 10.1093/treephys/tpad087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 06/28/2023] [Accepted: 07/02/2023] [Indexed: 07/08/2023]
Abstract
Metabolomics studies are becoming increasingly common for understanding how plant metabolism responds to changes in environmental conditions, genetic manipulations and treatments. Despite the recent advances in metabolomics workflow, the sample preparation process still limits the high-throughput analysis in large-scale studies. Here, we present a highly flexible robotic system that integrates liquid handling, sonication, centrifugation, solvent evaporation and sample transfer processed in 96-well plates to automatize the metabolite extraction from leaf samples. We transferred an established manual extraction protocol performed to a robotic system, and with this, we show the optimization steps required to improve reproducibility and obtain comparable results in terms of extraction efficiency and accuracy. We then tested the robotic system to analyze the metabolomes of wild-type and four transgenic silver birch (Betula pendula Roth) lines under unstressed conditions. Birch trees were engineered to overexpress the poplar (Populus × canescens) isoprene synthase and to emit various amounts of isoprene. By fitting the different isoprene emission capacities of the transgenic trees with their leaf metabolomes, we observed an isoprene-dependent upregulation of some flavonoids and other secondary metabolites as well as carbohydrates, amino acid and lipid metabolites. By contrast, the disaccharide sucrose was found to be strongly negatively correlated to isoprene emission. The presented study illustrates the power of integrating robotics to increase the sample throughput, reduce human errors and labor time, and to ensure a fully controlled, monitored and standardized sample preparation procedure. Due to its modular and flexible structure, the robotic system can be easily adapted to other extraction protocols for the analysis of various tissues or plant species to achieve high-throughput metabolomics in plant research.
Collapse
Affiliation(s)
- Marko Bertić
- Research Unit Environmental Simulation (EUS), Environmental Health Center (EHC), Helmholtz Zentrum München, Ingolstädter Landstr. 1, Neuherberg 85764, Germany
| | - Ina Zimmer
- Research Unit Environmental Simulation (EUS), Environmental Health Center (EHC), Helmholtz Zentrum München, Ingolstädter Landstr. 1, Neuherberg 85764, Germany
| | - David Andrés-Montaner
- Atmospheric Environmental Research, Institute of Meteorology and Climate Research, Karlsruhe Institute of Technology, Kreuzeckbahnstr. 19, Garmisch-Partenkirchen 82467, Germany
- Corteva Agriscience Spain S.L.U, Carreño, Spain
| | - Maaria Rosenkranz
- Research Unit Environmental Simulation (EUS), Environmental Health Center (EHC), Helmholtz Zentrum München, Ingolstädter Landstr. 1, Neuherberg 85764, Germany
- Institute of Plant Sciences, Ecology and Conservation Biology, University of Regensburg, Regensburg 93053, Germany
| | - Jaakko Kangasjärvi
- Faculty of Biological and Environmental Sciences, Viikki Plant Science Centre, University of Helsinki, Viikinkaari 1, P.O Box 65, FI-00014, Finland
| | - Jörg-Peter Schnitzler
- Research Unit Environmental Simulation (EUS), Environmental Health Center (EHC), Helmholtz Zentrum München, Ingolstädter Landstr. 1, Neuherberg 85764, Germany
| | - Andrea Ghirardo
- Research Unit Environmental Simulation (EUS), Environmental Health Center (EHC), Helmholtz Zentrum München, Ingolstädter Landstr. 1, Neuherberg 85764, Germany
| |
Collapse
|
4
|
Kochs S, Schiewe S, Zang Y, Schmidt R, Blume-Peytavi U, Roloff A, Luch A, Schreiver I. 4-Aminobenzoic acid, 2-phenoxyethanol and iodine used as tracers in a short-term in vivo-kinetics study for tattoo ink ingredients: Mass spectrometry method development and validation. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1229:123891. [PMID: 37820471 DOI: 10.1016/j.jchromb.2023.123891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 09/06/2023] [Accepted: 09/18/2023] [Indexed: 10/13/2023]
Abstract
Tattoos have been gaining popularity in recent years, leading to a growing interest in researching tattoo inks and the tattooing process itself. Since the exposure to soluble tattoo ink ingredients has not yet been investigated, we here present the method validation for a short-term biokinetics study on soluble tattoo ink ingredients. The three tracers 4-aminobenzoic acid (PABA), 2-phenoxyethanol (PEtOH) and iodine will be added to commercially available tattoo inks, which will subsequently be used on healthy study participants. Following the tattooing process, blood and urine will be sampled at specific time points and analysed for these tracers. For this purpose, a method using liquid chromatography separation coupled to a quadrupole time-of-flight mass spectrometer (LC-QTOF-MS) in positive and negative ESI mode for the quantification of PABA, PEtOH and selected metabolites and an inductively-coupled plasma (ICP)-MS method for the determination of iodine were developed and validated. For LC-QTOF-MS analysis, the most applicable additives for LC eluents (0.01 % formic acid for positive and 0.005 % acetic acid for negative mode) were identified. Protein precipitation with acetonitrile was chosen for sample preparation. The methods were validated for selectivity, specificity, carryover, linearity, limit of detection (LOD) and quantification (LOQ), matrix effects, accuracy and precision, stability under different conditions and dilution integrity according to national and international guidelines with an allowed maximum variation of ±15 %. The LC-QTOF-MS method met the imposed guideline criteria for most parameters, however, some metabolites showed strong matrix effects. Validation of the ICP-MS method revealed that the KED-H2 collision mode is superior to the standard analysis mode due to enhanced method accuracy. The methods were validated for the relevant matrices plasma, urine, tattoo ink and tattoo consumables and proved to be applicable for the main target substances in the short-term biokinetics study. A proof-of-concept study showed successful quantification of iodine and PABA metabolites. The PEtOH metabolite was also quantified, but showed strong matrix effects in urine. Therefore standard addition was selected as an alternative quantification method.
Collapse
Affiliation(s)
- Susanne Kochs
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany.
| | - Sandra Schiewe
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany
| | - Yalei Zang
- University of Potsdam, Institute of Nutritional Science, Arthur-Scheunert-Allee 114-116, 14558 Nuthetal, Germany
| | - Roman Schmidt
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany
| | - Ulrike Blume-Peytavi
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Department of Dermatology, Venereology and Allergology, Clinical Research Center for Hair and Skin Science, Charitéplatz 1, 10117 Berlin, Germany
| | - Alexander Roloff
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany
| | - Andreas Luch
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany
| | - Ines Schreiver
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, Berlin, Germany
| |
Collapse
|
5
|
Mehrban M, Madrakian T, Afkhami A, Jalal NR. Fabrication of impedimetric sensor based on metallic nanoparticle for the determination of mesna anticancer drug. Sci Rep 2023; 13:11381. [PMID: 37452101 PMCID: PMC10349103 DOI: 10.1038/s41598-023-38643-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023] Open
Abstract
Electrochemical impedance spectroscopy (EIS) is a highly effective technique for studying the surface of electrodes in great detail. EIS-based electrochemical sensors have been widely reported, which measure the charge transfer resistance (Rct) of redox probes on electrode surfaces to monitor the binding of target molecules. One of the protective drugs against hemorrhagic cystitis caused by oxazaphosphorine chemotherapy drugs such as ifosfamide, cyclophosphamide and trophosphamide is Mesna (sodium salt of 2-mercaptoethanesulfonate). The increase in the use of Mesna due to the high consumption of anti-cancer drugs, the determination of this drug in biological samples is of particular importance. So far, no electrochemical method has been reported to measure Mesna. In this research, a novel impedimetric sensor based on a glassy carbon electrode (GCE) modified with oxidized multiwalled carbon nanotubes (MWCNTs)/gold nanoparticle (AuNPs) (denoted as Au NPs/MWCNTs/GCE) for impedimetric determination of Mesna anticancer drug was developed. The modified electrode materials were characterized by field emission scanning electron microscopy (FESEM), energy dispersive X-ray (EDX), and EIS. The electrochemical behavior of Mesna at the surface of Au NPs/MWCNTs/GCE was studied by an impedimetric method. The detection mechanism of Mesna using the proposed impedimetric sensor relied on the increase in the Rct value of [Fe (CN)6]3-/4- as an electrochemical probe in the presence of Mesna compared to the absence of Mesna as the analyte. Under the optimum condition, which covered two linear dynamic ranges from 0.06 nmol L-1 to 1.0 nmol L-1 and 1.0 nmol L-1 to 130.0 µmol L-1, respectively. The detection limit was 0.02 nmol L-1. Finally, the performance of the proposed sensor was investigated for Mesna electrochemical detection in biological samples.
Collapse
Affiliation(s)
- Maryam Mehrban
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| | - Tayyebeh Madrakian
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, 6517838695, Iran.
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| | | |
Collapse
|
6
|
Lab-in-syringe automated protein precipitation and salting-out homogenous liquid-liquid extraction coupled online to UHPLC-MS/MS for the determination of beta-blockers in serum. Anal Chim Acta 2023; 1251:340966. [PMID: 36925276 DOI: 10.1016/j.aca.2023.340966] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 02/09/2023] [Accepted: 02/09/2023] [Indexed: 02/19/2023]
Abstract
A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions. The extract is then separated and diluted in-syringe before being submitted to online coupled UHPLC-MS/MS. A 1 mL glass syringe containing a small stir bar for solution mixing at up to 3000 rpm, was used to deal with sample volumes as small as 100 μL. A sample throughput of 7 h-1 was achieved by performing the chromatographic run and sample preparation procedure in parallel. Linear working ranges were obtained for all analytes between 5 and 100 ng mL-1, with LOD values ranging from 0.4 to 1.5 ng mL-1. Accuracy values in the range of 88.2-106% and high precision of <11% RSD suggest applicability for routine analysis that can be further improved using deuterated standards.
Collapse
|
7
|
Murakami T, Ishimaru R, Minami E, Iwamuro Y, Takamura N, Torai A, Watanabe T, Miki A, Katagi M, Kusano M, Tsuchihashi H, Zaitsu K, Chinaka S. Development of two fully automated quick, easy, cheap, effective, rugged, and safe pretreatment methods for the extraction of psychotropic drugs from whole blood samples. J Sep Sci 2023; 46:e2200681. [PMID: 36479834 DOI: 10.1002/jssc.202200681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 11/17/2022] [Accepted: 11/29/2022] [Indexed: 12/13/2022]
Abstract
Quick, easy, cheap, effective, rugged, and safe extraction strategies are becoming increasingly adopted in various analytical fields to determine drugs in biological specimens. In the present study, we developed two fully automated quick, easy, cheap, effective, rugged, and safe extraction methods based on acetonitrile salting-out assisted liquid-liquid extraction (method 1) and acetonitrile salting-out assisted liquid-liquid extraction followed by dispersive solid-phase extraction (method 2) using a commercially available automated liquid-liquid extraction system. We applied these methods to the extraction of 14 psychotropic drugs (11 benzodiazepines and carbamazepine, quetiapine, and zolpidem) from whole blood samples. Both methods prior to liquid chromatography-tandem mass spectrometry analysis exhibited high linearity of calibration curves (correlation coefficients, > 0.9997), ppt level detection sensitivities, and satisfactory precisions (< 8.6% relative standard deviation), accuracies (within ± 16% relative error), and matrix effects (81-111%). Method 1 provided higher recovery rates (80-91%) than method 2 (72-86%), whereas method 2 provided higher detection sensitivities (limits of detection, 0.003-0.094 ng/mL) than method 1 (0.025-0.47 ng/mL) owing to the effectiveness of its dispersive solid-phase extraction cleanup step. These fully automated extraction methods realize reliable, labor-saving, user-friendly, and hygienic extraction of target analytes from whole blood samples.
Collapse
Affiliation(s)
- Takaya Murakami
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan.,Institute of Science and Engineering, Kanazawa University, Kanazawa, Japan
| | - Reiko Ishimaru
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan
| | - Eriko Minami
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan
| | - Yoshiaki Iwamuro
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan
| | | | - Aya Torai
- Shimadzu Trustech Corporation, Kyoto, Japan
| | | | - Akihiro Miki
- Forensic Science Laboratory, Osaka Prefectural Police Headquarters, Osaka, Japan
| | - Munehiro Katagi
- Department of Legal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
| | - Maiko Kusano
- Department of Legal Medicine, Showa University School of Medicine, Tokyo, Japan
| | | | - Kei Zaitsu
- Multimodal Informatics and Wide-data Analytics Laboratory, Department of Computational Systems Biology, Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama, Japan
| | - Satoshi Chinaka
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan.,Department of Forensic Medicine and Pathology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
| |
Collapse
|
8
|
Development and validation of an LC-MS/MS method for the assessment of Isoxazole, a bioactive analogue of curcumin in rat plasma: Application to a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1212:123488. [DOI: 10.1016/j.jchromb.2022.123488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 09/16/2022] [Accepted: 09/29/2022] [Indexed: 11/07/2022]
|
9
|
Surendran A, Atefi N, Zhang H, Aliani M, Ravandi A. Defining Acute Coronary Syndrome through Metabolomics. Metabolites 2021; 11:685. [PMID: 34677400 PMCID: PMC8540033 DOI: 10.3390/metabo11100685] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 09/19/2021] [Accepted: 09/25/2021] [Indexed: 02/06/2023] Open
Abstract
As an emerging platform technology, metabolomics offers new insights into the pathomechanisms associated with complex disease conditions, including cardiovascular diseases. It also facilitates assessing the risk of developing the disease before its clinical manifestation. For this reason, metabolomics is of growing interest for understanding the pathogenesis of acute coronary syndromes (ACS), finding new biomarkers of ACS, and its associated risk management. Metabolomics-based studies in ACS have already demonstrated immense potential for biomarker discovery and mechanistic insights by identifying metabolomic signatures (e.g., branched-chain amino acids, acylcarnitines, lysophosphatidylcholines) associated with disease progression. Herein, we discuss the various metabolomics approaches and the challenges involved in metabolic profiling, focusing on ACS. Special attention has been paid to the clinical studies of metabolomics and lipidomics in ACS, with an emphasis on ischemia/reperfusion injury.
Collapse
Affiliation(s)
- Arun Surendran
- Cardiovascular Lipidomics Laboratory, St. Boniface Hospital, Albrechtsen Research Centre, Winnipeg, MB R2H 2A6, Canada; (A.S.); (N.A.); (H.Z.)
- Mass Spectrometry and Proteomics Core Facility, Rajiv Gandhi Centre for Biotechnology, Thiruvananthapuram 695014, Kerala, India
- Department of Physiology and Pathophysiology, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R2H 2A6, Canada
| | - Negar Atefi
- Cardiovascular Lipidomics Laboratory, St. Boniface Hospital, Albrechtsen Research Centre, Winnipeg, MB R2H 2A6, Canada; (A.S.); (N.A.); (H.Z.)
| | - Hannah Zhang
- Cardiovascular Lipidomics Laboratory, St. Boniface Hospital, Albrechtsen Research Centre, Winnipeg, MB R2H 2A6, Canada; (A.S.); (N.A.); (H.Z.)
| | - Michel Aliani
- Faculty of Agricultural and Food Sciences, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R2H 2A6, Canada;
| | - Amir Ravandi
- Cardiovascular Lipidomics Laboratory, St. Boniface Hospital, Albrechtsen Research Centre, Winnipeg, MB R2H 2A6, Canada; (A.S.); (N.A.); (H.Z.)
- Department of Physiology and Pathophysiology, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R2H 2A6, Canada
- Section of Cardiology, Department of Medicine, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R2H 2A6, Canada
| |
Collapse
|
10
|
Acquavia MA, Foti L, Pascale R, Nicolò A, Brancaleone V, Cataldi TRI, Martelli G, Scrano L, Bianco G. Detection and quantification of Covid-19 antiviral drugs in biological fluids and tissues. Talanta 2021; 224:121862. [PMID: 33379073 PMCID: PMC7642756 DOI: 10.1016/j.talanta.2020.121862] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/30/2020] [Accepted: 11/02/2020] [Indexed: 12/15/2022]
Abstract
Since coronavirus disease 2019 (COVID-19) started as a fast-spreading pandemic, causing a huge number of deaths worldwide, several therapeutic options have been tested to counteract or reduce the clinical symptoms of patients infected with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently, no specific drugs for COVID-19 are available, but many antiviral agents have been authorised by several national agencies. Most of them are under investigation in both preclinical and clinical trials; however, pharmacokinetic and metabolism studies are needed to identify the most suitable dose to achieve the desired effect on SARS-CoV-2. Therefore, the efforts of the scientific community have focused on the screening of therapies able to counteract the most severe effects of the infection, as well as on the search of sensitive and selective analytical methods for drug detection in biological matrices, both fluids and tissues. In the last decade, many analytical methods have been proposed for the detection and quantification of antiviral compounds currently being tested for COVID-19 treatment. In this review, a critical discussion on the overall analytical procedure is provided, i.e (a) sample pre-treatment and extraction methods such as protein precipitation (PP), solid-phase extraction (SPE), liquid-liquid extraction (LLE), ultrasound-assisted extraction (UAE) and QuEChERS (quick, easy, cheap, effective, rugged and safe), (b) detection and quantification methods such as potentiometry, spectrofluorimetry and mass spectrometry (MS) as well as (c) methods including a preliminary separation step, such as high performance liquid chromatography (HPLC) and capillary electrophoresis (CE) coupled to UV-Vis or MS detection. Further current trends, advantages and disadvantages and prospects of these methods have been discussed, to help the analytical advances in reducing the harm caused by the SARS-CoV-2 virus.
Collapse
Affiliation(s)
- Maria A Acquavia
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy; ALMAGISI S.r.l Corso Italia, 27-39100, Bolzano, Italy.
| | - Luca Foti
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| | - Raffaella Pascale
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| | - Antonia Nicolò
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| | - Vincenzo Brancaleone
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| | - Tommaso R I Cataldi
- Università Degli Studi di Bari Aldo Moro, Dipartimento di Chimica, Via E. Orabona, 4-70126, Bari, Italy.
| | - Giuseppe Martelli
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| | - Laura Scrano
- Università Degli Studi Della Basilicata, Dipartimento Delle Culture Europee e Del Mediterraneo: Arch., Ambiente, Patrimoni Culturali, Via Lanera, 20-75100, Matera, Italy.
| | - Giuliana Bianco
- Università Degli Studi Della Basilicata, Dipartimento di Scienze, Via Dell'Ateneo Lucano, 10-85100, Potenza, Italy.
| |
Collapse
|
11
|
High-throughput screening for high-efficiency small-molecule biosynthesis. Metab Eng 2020; 63:102-125. [PMID: 33017684 DOI: 10.1016/j.ymben.2020.09.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/31/2020] [Accepted: 09/01/2020] [Indexed: 01/14/2023]
Abstract
Systems metabolic engineering faces the formidable task of rewiring microbial metabolism to cost-effectively generate high-value molecules from a variety of inexpensive feedstocks for many different applications. Because these cellular systems are still too complex to model accurately, vast collections of engineered organism variants must be systematically created and evaluated through an enormous trial-and-error process in order to identify a manufacturing-ready strain. The high-throughput screening of strains to optimize their scalable manufacturing potential requires execution of many carefully controlled, parallel, miniature fermentations, followed by high-precision analysis of the resulting complex mixtures. This review discusses strategies for the design of high-throughput, small-scale fermentation models to predict improved strain performance at large commercial scale. Established and promising approaches from industrial and academic groups are presented for both cell culture and analysis, with primary focus on microplate- and microfluidics-based screening systems.
Collapse
|
12
|
Satyavert, Gupta S, Nair AB, Attimarad M. Development and validation of bioanalytical method for the determination of hydrazinocurcumin in rat plasma and organs by HPLC-UV. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1156:122310. [PMID: 32835908 DOI: 10.1016/j.jchromb.2020.122310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/06/2020] [Accepted: 08/09/2020] [Indexed: 12/24/2022]
Abstract
Hydrazinocurcumin is a semi-synthetic analogue of curcumin with superior anticancer and anti-angiogenic activities. In the present work a simple and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method for quantitative evaluation of hydrazinocurcumin in plasma and various organs of rats including liver, kidneys, brain, heart, lungs and spleen was developed. Hydrazinocurcumin was separated using octadecylsilane (Inertsil-ODS-3V) column in an isocratic mode using mobile phase consisting of methanol-acetonitrile- water (36:27:37 v/v) with flow rate of 1.0 ml/min. Ultra violet (UV) detection of hydrazinocurcumin and internal standard was carried out in dual-wavelength mode at 332 nm and 380 nm, respectively. The linearity of hydrazinocurcumin was found in the range 0.05-5 µg/ml with a correlation coefficient of r2 > 0.999. The developed bioanalytical method shown higher inter-day accuracy (98.04-105.94%) and precision (0.89-10.24). The average recoveries of hydrazinocurcumin from rat plasma and various organs were in the range of 96-101.75% and 92.25-99.0%, respectively. The bioanalytical samples shows good stability of hydrazinocurcumin at different storage and handling conditions. In conclusion, this validated HPLC-UV method could be applied effectively for evaluation of hydazinocurcumin for the pharmacokinetic and organ distribution studies.
Collapse
Affiliation(s)
- Satyavert
- Department of Pharmacology, M. M. College of Pharmacy, M. M. (Deemed to be University), Mullana, (Ambala), Haryana, India
| | - Sumeet Gupta
- Department of Pharmacology, M. M. College of Pharmacy, M. M. (Deemed to be University), Mullana, (Ambala), Haryana, India.
| | - Anroop B Nair
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia
| | - Mahesh Attimarad
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia
| |
Collapse
|
13
|
Abrantes Dias AS, Amaral Pinto JC, Magalhães M, Mendes VM, Manadas B. Analytical methods to monitor dopamine metabolism in plasma: Moving forward with improved diagnosis and treatment of neurological disorders. J Pharm Biomed Anal 2020; 187:113323. [DOI: 10.1016/j.jpba.2020.113323] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 04/16/2020] [Accepted: 04/17/2020] [Indexed: 12/16/2022]
|
14
|
Onat B, Rosales-Solano H, Pawliszyn J. Development of a Biocompatible Solid Phase Microextraction Thin Film Coating for the Sampling and Enrichment of Peptides. Anal Chem 2020; 92:9379-9388. [DOI: 10.1021/acs.analchem.0c01846] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Bora Onat
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| | | | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| |
Collapse
|
15
|
Mancini RSN, de Jesus FP, da Rocha AM, Carvalho AZ, Rocha DL. An automated flow system for in-line extraction of proteins and separation of jacalin using a low-cost stationary phase. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1130-1131:121806. [PMID: 31670106 DOI: 10.1016/j.jchromb.2019.121806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 08/12/2019] [Accepted: 09/13/2019] [Indexed: 11/28/2022]
Abstract
Lectins are carbohydrate binding proteins with many physiological and biotechnological applications. Isolation of proteins is normally time-consuming and encompasses multiple and, sometimes, complicated steps that hinder reproducibility and yield. Affinity chromatography is an efficient way to simplify and improve protein purification, however often requiring an expensive and fragile stationary phase. In this regard, automated flow-based systems minimize the time for extraction of species from solid samples without hindering the features of batch procedures. In this work, a new inexpensive affinity-based stationary phase was developed for in-line separation of jacalin, a galactose-binding lectin from jackfruit seeds. In the flow manifold, in-line extraction of proteins was also carried out with continuous monitoring using the spectrophotometric Biuret assay. For protein determination, linear response was observed from 3.0 to 15 g L-1. The results of the analysis of protein extracts from jackfruit seeds obtained with the herein described procedure and batch procedure agreed with 95% confidence level. Quantitative extraction of proteins from jackfruit seed powder required recirculation of extraction buffer for 15 min through a lab-made polymethylmethacrylate (PMMA) column containing 200 mg of the crude seed powder. In the chromatographic step, jacalin was isolated after 300 s. Therefore, three essential steps for jacalin isolation were performed in one manifold in a fast way, minimizing sample consumption and solution handling. Additionally, the versatile and multi-task developed flow manifold can be useful for routine analysis and preparative procedures, being adaptable for the extraction and separation of other species from solid matrixes with continuous monitoring of the processes.
Collapse
Affiliation(s)
- Rodrigo S N Mancini
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, SP, Brazil
| | - Fernanda P de Jesus
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, SP, Brazil
| | - Alessandra M da Rocha
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, SP, Brazil
| | - Alexandre Z Carvalho
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, SP, Brazil
| | - Diogo L Rocha
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, SP, Brazil.
| |
Collapse
|
16
|
Soulès R, Audouard-Combe F, Huc-Claustre E, de Medina P, Rives A, Chatelut E, Dalenc F, Franchet C, Silvente-Poirot S, Poirot M, Allal B. A fast UPLC-HILIC method for an accurate quantification of dendrogenin A in human tissues. J Steroid Biochem Mol Biol 2019; 194:105447. [PMID: 31415823 DOI: 10.1016/j.jsbmb.2019.105447] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 08/05/2019] [Accepted: 08/11/2019] [Indexed: 11/20/2022]
Abstract
Dendrogenin A (DDA) is a newly-discovered steroidal alkaloid, which remains to date the first ever found in mammals. DDA is a cholesterol metabolites that induces cancer cell differentiation and death in vitro and in vivo, and thus behave like a tumor suppressor metabolite. Preliminary studies performed on 10 patients with estrogen receptor positive breast cancers (ER(+)BC) showed a strong decrease in DDA levels between normal matched tissue and tumors. This suggests that a deregulation on DDA metabolism is associated with breast carcinogenesis. To further investigate DDA metabolism on large cohorts of patients we have developed an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS) procedure for the quantification of DDA in liquid and in solid tissues. This method enabled the identification of DDA analogues such as its geometric isomer C17 and dendrogenin B (C26) in human samples showing that other 5,6α-epoxycholesterol conjugation products with biogenic amines exist as endogenous metabolites . We report here the first complete method of quantification of DDA in liquid and solid tissues using hydrophilic interaction liquid chromatography (HILIC). Two different methods of extraction using either a Bligh and Dyer organic extraction or protein precipitation were successfully applied to quantify DDA in solid and liquid tissues. The protein precipitation method was the fastest. The fact that this method is automatable opens up possibilities to study DDA metabolism in large cohorts of patients.
Collapse
Affiliation(s)
- Régis Soulès
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France
| | | | - Emilie Huc-Claustre
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France
| | - Philippe de Medina
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France
| | - Arnaud Rives
- Affichem, Toulouse, France; Dendrogenix, Liège, Belgium
| | - Etienne Chatelut
- Team "Dose individualization of anticancer drugs », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Institut Claudius Regaud, Institut Universitaire du Cancer-Oncopole, Toulouse, France
| | - Florence Dalenc
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France; Institut Claudius Regaud, Institut Universitaire du Cancer-Oncopole, Toulouse, France
| | - Camille Franchet
- Service d'Anatomo-Pathologie, Centre Hospitalier Universitaire de Toulouse, Institut Universitaire du Cancer de Toulouse-Oncopole, Toulouse, France
| | - Sandrine Silvente-Poirot
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France
| | - Marc Poirot
- Team « Cholesterol metabolism and therapeutic innovations », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Equipe labellisée par la Ligue Nationale Contre le Cancer, France.
| | - Ben Allal
- Team "Dose individualization of anticancer drugs », Cancer Research Center of Toulouse, UMR 1037 INSERM-University of Toulouse, Toulouse, France; Institut Claudius Regaud, Institut Universitaire du Cancer-Oncopole, Toulouse, France.
| |
Collapse
|
17
|
Li L, Ma S, Qin Y, Liu L. Enhanced UHPLC-MS/MS determination of a therapeutic heptapeptide mimic for inflammatory-related diseases in rat plasma: application to a pharmacokinetic study. RSC Adv 2019; 9:32699-32711. [PMID: 35529728 PMCID: PMC9073091 DOI: 10.1039/c9ra05114g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 09/21/2019] [Indexed: 11/21/2022] Open
Abstract
The seven amino acid peptide, GQTYTSG (named as SP), a peptide mimic derived from hypervariable region 1 (HVR1) of the hepatitis C virus (HCV) has presented remarkable anti-inflammatory activities in previous experiments, indicating that it could be a novel therapeutic peptide candidate for different inflammation-related diseases, such as HCV infection and asthma. A heptapeptide mimic discovery study highlighted the need for the development of quantitative bioanalytical assays for measuring the levels of SP. Herein, a reliable and sensitive ultrahigh-performance liquid chromatography (UHPLC) with tandem mass spectrometry (MS/MS) assay was established and validated for the determination of SP in rat plasma. C-11, with two amino acid substitutions compared to SP (Glycine 1 and Glycine 7) and a disulfide, acted as an internal standard (IS). SP and C-11 were isolated from acidified plasma using protein precipitation and the extracts were analyzed by reversed-phase UHPLC-MS/MS detection. We used an SHIM-PACK GISS C18 (2.1 × 100 mm, 1.9 μm) column with water containing 0.2% acetic acid as the aqueous mobile phase and methanol as the organic mobile phase with a 0.3 mL min-1 flow rate. We used an AB SCIEX TripleQuad™ 5500 mass spectrometer equipped with a TurboIon Spray interface and operated it in positive-ion mode. Multiple reaction monitoring (MRM) was used for the quantification of the precursor to the product ion at m/z 713.3 → 432.2 for SP and m/z 803.2 → 539.1 for IS. The method was fully validated according to the US Food and Drug Administration (FDA) guideline (2018), and provided satisfactory accuracy, precision, and reproducibility for the quantification of SP in rat plasma. Excellent linearity was achieved (r > 0.9977) over a linear dynamic range of 0.1-200 ng mL-1 with a lower limit of quantification (LLOQ) of 0.1 ng mL-1. The validated assay was applied to gain the pharmacokinetic (PK) parameters and the concentration-time profile for SP after subcutaneous administration in rats.
Collapse
Affiliation(s)
- Liang Li
- Center for Pharmacological Evaluation and Research, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry Shanghai 200437 PR China +8621-65043855
- State Key Laboratory of New Drug and Pharmaceutical Process Shanghai 201203 PR China
- Shanghai Professional and Technical Service Center for Biological Material Drug-Ability Evaluation Shanghai 200437 PR China
| | - Shumei Ma
- Department of Pharmacology, School of Pharmacy, Fudan University Shanghai 201203 PR China
| | - Yan Qin
- Center for Pharmacological Evaluation and Research, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry Shanghai 200437 PR China +8621-65043855
- State Key Laboratory of New Drug and Pharmaceutical Process Shanghai 201203 PR China
- Shanghai Professional and Technical Service Center for Biological Material Drug-Ability Evaluation Shanghai 200437 PR China
| | - Li Liu
- Center for Pharmacological Evaluation and Research, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry Shanghai 200437 PR China +8621-65043855
- State Key Laboratory of New Drug and Pharmaceutical Process Shanghai 201203 PR China
- Shanghai Professional and Technical Service Center for Biological Material Drug-Ability Evaluation Shanghai 200437 PR China
| |
Collapse
|
18
|
Gu H, Zhao Y, DeMichele M, Zheng N, Zhang YJ, Pillutla R, Zeng J. Eliminating Preparation of Multisample External Calibration Curves and Dilution of Study Samples Using the Multiple Isotopologue Reaction Monitoring (MIRM) Technique in Quantitative LC-MS/MS Bioanalysis. Anal Chem 2019; 91:8652-8659. [DOI: 10.1021/acs.analchem.9b02136] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Huidong Gu
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Yue Zhao
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Marissa DeMichele
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Naiyu Zheng
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Yan J. Zhang
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Renuka Pillutla
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| | - Jianing Zeng
- Bioanalytical Sciences, Research & Development, Bristol-Myers Squibb, Route 206 & Province Line Road, Princeton, New Jersey 08543, United States
| |
Collapse
|
19
|
Lee J, Kim H, Sohn A, Yeo I, Kim Y. Cost-Effective Automated Preparation of Serum Samples for Reproducible Quantitative Clinical Proteomics. J Proteome Res 2019; 18:2337-2345. [PMID: 30985128 DOI: 10.1021/acs.jproteome.9b00023] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Reproducible sample preparation remains a significant challenge in large-scale clinical research using selected reaction monitoring-mass spectrometry (SRM-MS), which enables a highly sensitive multiplexed assay. Although automated liquid-handling platforms have tremendous potential for addressing this issue, the high cost of their consumables is a drawback that renders routine operation expensive. Here we evaluated the performance of a liquid-handling platform in preparing serum samples compared with a standard experiment while reducing the outlay for consumables, such as tips, wasted reagents, and reagent stock plates. A total of 26 multiplex assays were quantified by SRM-MS using four sets of 24 pooled human serum aliquots; the four sets used a fixed number (1, 4, 8, or 24) of tips to dispense digestion reagents. This study demonstrated that the use of 4 or 8 tips is comparable to 24 tips (standard experiment), as evidenced by their coefficients of variation: 13.5% (for 4 and 8 tips) versus 12.0% (24 tips). Thus we can save 37% of the total experimental cost compared with the standard experiment, maintaining nearly equivalent reproducibility. The routine operation of cost-effective liquid-handling platforms can enable researchers to process large-scale samples with high throughput, adding credibility to their findings by minimizing human error.
Collapse
Affiliation(s)
| | - Hyunsoo Kim
- Institute of Medical and Biological Engineering, MRC , Seoul National University , Seoul , Korea
| | | | - Injoon Yeo
- Interdisciplinary Program of Bioengineering , Seoul National University College of Engineering , Seoul , Korea
| | - Youngsoo Kim
- Institute of Medical and Biological Engineering, MRC , Seoul National University , Seoul , Korea.,Interdisciplinary Program of Bioengineering , Seoul National University College of Engineering , Seoul , Korea
| |
Collapse
|
20
|
Vondroušová J, Mikoška M, Syslová K, Böhmová A, Tejkalová H, Vacek L, Kodym P, Krsek D, Horáček J. Monitoring of kynurenine pathway metabolites, neurotransmitters and their metabolites in blood plasma and brain tissue of individuals with latent toxoplasmosis. J Pharm Biomed Anal 2019; 170:139-152. [PMID: 30925271 DOI: 10.1016/j.jpba.2019.03.039] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 03/14/2019] [Accepted: 03/17/2019] [Indexed: 12/17/2022]
Abstract
The aim of the presented work was to develop a highly sensitive, accurate and rapid analytical method for the determination of concentration levels of tryptophan and its metabolites of kynurenine catabolic pathway, as well as neurotransmitters and their metabolites in complex biological matrices (brain tissue and blood plasma). The developed analytical method consists of analytes separation from the biological matrices by protein precipitation (blood plasma) or solvent extraction (brain tissue), derivatization of the analytes and their detection by high-performance liquid chromatography combined with mass spectrometry. Individual steps of the whole process were optimized and the method was validated in the terms of selectivity, linearity (R2≥0.980), precision (RSD ≤ 13.3%), recovery (≥82.0%), limit of detection (1.8 ng/mL of blood plasma, 2.2 pg/mg of brain tissue) and limit of quantification (2.5 ng/mL of blood plasma, 2.8 pg/mg of brain tissue). The method was subsequently verified by an animal study, where the concentration levels of the analytes in biological matrices (blood plasma and brain tissue) of T. gondii - infected rats and control animals were compared. All the data obtained from the animal study were statistically evaluated. Increased concentration levels of kynurenine catabolic pathway metabolites (e.g. kynurenine, 3-hydroxykynurenine, quinolinic acid) were observed in the case of T. gondii - infected rats in contrast to the control group. The opposite effect was determined in the case of serotonin and its metabolite 5-hydroxyindoleacetic acid, where higher concentration levels were found in blood plasma of healthy subjects. Finally, Principal Component Analysis (PCA) was utilized for a score plot formation. PCA score plots have demonstrated the similarities of individuals within each group and the differences among the groups.
Collapse
Affiliation(s)
- Jana Vondroušová
- Department of Organic Technology, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Miloš Mikoška
- Department of Organic Technology, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Kamila Syslová
- Department of Organic Technology, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic.
| | - Adéla Böhmová
- Department of Organic Technology, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Hana Tejkalová
- National Institute of Mental Health, Topolová 748, 250 67, Klecany, Czech Republic
| | - Lukáš Vacek
- Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic
| | - Petr Kodym
- The National Institute of Public Health, Šrobárova 48, 100 42, Prague 10, Czech Republic
| | - Daniel Krsek
- The National Institute of Public Health, Šrobárova 48, 100 42, Prague 10, Czech Republic
| | - Jiří Horáček
- National Institute of Mental Health, Topolová 748, 250 67, Klecany, Czech Republic
| |
Collapse
|
21
|
Matos DMD, Viana MR, Alvim MCDO, Carvalho LSAD, Leite LHR, Da Silva Filho AA, Nascimento JWL. Pharmacokinetic profile and oral bioavailability of Kaurenoic acid from Copaifera spp. in rats. Fitoterapia 2018; 128:142-147. [DOI: 10.1016/j.fitote.2018.05.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 05/04/2018] [Accepted: 05/13/2018] [Indexed: 01/10/2023]
|
22
|
Recent advances in biological sample preparation methods coupled with chromatography, spectrometry and electrochemistry analysis techniques. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.02.005] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
23
|
Park JE, Kim TE, Shin KH. Quantitative Analysis of Four Catechins from Green Tea Extract in Human Plasma Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Pharmacokinetic Studies. Molecules 2018; 23:molecules23040984. [PMID: 29690635 PMCID: PMC6017899 DOI: 10.3390/molecules23040984] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 04/15/2018] [Accepted: 04/19/2018] [Indexed: 01/17/2023] Open
Abstract
Green tea is consumed as a beverage worldwide and has beneficial effects, such as a lower risk of cardiovascular disease and cancer. A quantitative analysis of the beneficial components in plasma is important for understanding the potential health benefits of green tea. Four catechins—epigallocatechin-3-gallate (EGCG), epicatechin-3-gallate (ECG), epigallocatechin (EGC), and epicatechin (EC)—which account for the majority of the components of green tea, were analyzed by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). In this study, a validated method was optimized to obtain the blood concentrations after the one-time ingestion of 630 mg green tea extract with digoxin and then after the ingestion of 630 mg green tea repeatedly for 15 days. The calibration curve, including the LLOQ, was constructed over 1–500 ng/mL for EGCG, ECG, and EGC and 0.1–50 ng/mL for EC. The method for inter- and intra-validation was applied, acceptable for both accuracy and precision. We successfully developed an appropriate UPLC-MS/MS method for human plasma with good reproducibility and sensitivity. Thus, this method could be applied for future preclinical and clinical studies on EGCG, ECG, EGC, and EC.
Collapse
Affiliation(s)
- Jeong-Eun Park
- Research Institute of Pharmaceutical Sciences, College of Pharmacy, Kyungpook National University, Daegu 41566, Korea.
| | - Tae-Eun Kim
- Department of Clinical Pharmacology, Konkuk University Medical Center, Seoul 05029, Korea.
| | - Kwang-Hee Shin
- Research Institute of Pharmaceutical Sciences, College of Pharmacy, Kyungpook National University, Daegu 41566, Korea.
| |
Collapse
|
24
|
Abstract
Online and automated sample extraction is widely used to increase the throughput and improve the quality of LC-MS/MS analysis. In this article, we review the most commonly used online sample extraction methodologies including online SPE, turbulent flow chromatography, online DBS extraction and online immunoaffinity extraction. We also review the offline automated sample extraction platforms, including custom robot scripts for the automation of individual steps during sample extraction, the robot scripts for the automation of individual assays, and the platform for integrated multiple sample extraction. The most recent developments and future trends in this area are also discussed.
Collapse
|
25
|
Comparison of different serum sample extraction methods and their suitability for mass spectrometry analysis. Saudi Pharm J 2015; 23:689-97. [PMID: 26702265 PMCID: PMC4669428 DOI: 10.1016/j.jsps.2015.01.023] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Accepted: 01/27/2015] [Indexed: 11/24/2022] Open
Abstract
Mass spectrometry has been widely used, particularly in pharmacokinetic investigations and for therapeutic drug monitoring purposes. Like any other analytical method some difficulties exist in employing mass spectrometry, mainly when it is used to test biological samples, such as to detect drug candidates in mammalian serum, which is rich in proteins, lipids and other contents that may interfere with the investigational drug. The complexity of the serum proteome presents challenges for efficient sample preparation and adequate sensitivity for mass spectrometry analysis of drugs. Enrichment procedures prior to the drug analysis are often needed and as a result, the study of serum or plasma components usually demands either methods of purification or depletion of one or more. Selection of the best combination of sample introduction method is a crucial determinant of the sensitivity and accuracy of mass spectrometry. The aim of this study was to determine the highest serum protein precipitation activity of five commonly used sample preparation methods and test their suitability for mass spectrometry. We spiked three small molecules into rabbit serum and applied different protein precipitation methods to determine their precipitation activity and applicability as a mass spectrometry introductory tool.
Collapse
|
26
|
Current advances and strategies towards fully automated sample preparation for regulated LC–MS/MS bioanalysis. Bioanalysis 2014; 6:2441-59. [DOI: 10.4155/bio.14.161] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Robotic liquid handlers (RLHs) have been widely used in automated sample preparation for liquid chromatography–tandem mass spectrometry (LC–MS/MS) bioanalysis. Automated sample preparation for regulated bioanalysis offers significantly higher assay efficiency, better data quality and potential bioanalytical cost-savings. For RLHs that are used for regulated bioanalysis, there are additional requirements, including 21 CFR Part 11 compliance, software validation, system qualification, calibration verification and proper maintenance. This article reviews recent advances in automated sample preparation for regulated bioanalysis in the last 5 years. Specifically, it covers the following aspects: regulated bioanalysis requirements, recent advances in automation hardware and software development, sample extraction workflow simplification, strategies towards fully automated sample extraction, and best practices in automated sample preparation for regulated bioanalysis.
Collapse
|
27
|
Wu YT, Wu MT, Lin CC, Chien CF, Tsai TH. Pharmacokinetic Studies of Chinese Medicinal Herbs Using an Automated Blood Sampling System and Liquid Chromatography-mass Spectrometry. J Tradit Complement Med 2014; 2:33-40. [PMID: 24716112 PMCID: PMC3943008 DOI: 10.1016/s2225-4110(16)30068-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The safety of herbal products is one of the major concerns for the modernization of traditional Chinese medicine, and pharmacokinetic data of medicinal herbs guide us to design the rational use of the herbal formula. This article reviews the advantages of the automated blood sampling (ABS) systems for pharmacokinetic studies. In addition, three commonly used sample preparative methods, protein precipitation, liquid-liquid extraction and solid-phase extraction, are introduced. Furthermore, the definition, causes and evaluation of matrix effects in liquid chromatography-mass spectrometry (LC/MS) analysis are demonstrated. Finally, we present our previous works as practical examples of the application of ABS systems and LC/MS for the pharmacokinetic studies of Chinese medicinal herbs.
Collapse
Affiliation(s)
- Yu-Tse Wu
- Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan ; Department of Education and Research, Taipei City Hospital, Taipei, Taiwan
| | - Ming-Tsang Wu
- Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Chia-Chun Lin
- Institute of Pharmacology, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Chao-Feng Chien
- Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Tung-Hu Tsai
- Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan ; Department of Education and Research, Taipei City Hospital, Taipei, Taiwan
| |
Collapse
|
28
|
Biological sample preparation: attempts on productivity increasing in bioanalysis. Bioanalysis 2014; 6:1691-710. [DOI: 10.4155/bio.14.118] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Sample preparation is an important step of any biomedical analysis. Development and validation of fast, reproducible and reliable sample preparation methods would be very helpful in increasing productivity. Except for a few direct injection methods, almost all biological samples should at least be diluted before any analysis. Sometimes dilution is not possible because of the low concentration of the target analyte in the sample, and alternative pretreatments, such as filtration, precipitation and sample clean up using different extraction methods, are needed. This review focuses on the recent achievements in the pretreatment of biological samples and investigates them in six categories (i.e., dilution, filtration/dialysis, precipitation, extraction [solid-phase extraction, liquid–liquid extraction], novel techniques [turbulent flow chromatography, immunoaffinity method, electromembrane extraction] and combined methods). Each category will be discussed according to its productivity rate and suitability for routine analysis, and the discussed methods will be compared according to the mentioned indices.
Collapse
|
29
|
Laboratory automation of high-quality and efficient ligand-binding assays for biotherapeutic drug development. Bioanalysis 2013; 5:1635-48. [DOI: 10.4155/bio.13.141] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Background: Regulated bioanalytical laboratories that run ligand-binding assays in support of biotherapeutics development face ever-increasing demand to support more projects with increased efficiency. Laboratory automation is a tool that has the potential to improve both quality and efficiency in a bioanalytical laboratory. The success of laboratory automation requires thoughtful evaluation of program needs and fit-for-purpose strategies, followed by pragmatic implementation plans and continuous user support. Results: In this article, we present the development of fit-for-purpose automation of total walk-away and flexible modular modes. We shared the sustaining experience of vendor collaboration and team work to educate, promote and track the use of automation. Conclusion: The implementation of laboratory automation improves assay performance, data quality, process efficiency and method transfer to CRO in a regulated bioanalytical laboratory environment.
Collapse
|
30
|
Zheng N, Buzescu A, Pasas-Farmer S, Arnold ME, Ouyang Z, Jemal M, Peng Q, Van Vleet T, Zeng J. A simplified and completely automated workflow for regulated LC–MS/MS bioanalysis using cap-piercing direct sampling and evaporation-free solid phase extraction. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 921-922:64-74. [DOI: 10.1016/j.jchromb.2013.01.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Revised: 01/17/2013] [Accepted: 01/23/2013] [Indexed: 12/01/2022]
|
31
|
MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier. Bioanalysis 2012; 4:1311-26. [DOI: 10.4155/bio.12.77] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab® STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid–liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. Results: We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. Conclusion: The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.
Collapse
|
32
|
Recent development in software and automation tools for high-throughput discovery bioanalysis. Bioanalysis 2012; 4:1097-109. [DOI: 10.4155/bio.12.51] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Bioanalysis with LC–MS/MS has been established as the method of choice for quantitative determination of drug candidates in biological matrices in drug discovery and development. The LC–MS/MS bioanalytical support for drug discovery, especially for early discovery, often requires high-throughput (HT) analysis of large numbers of samples (hundreds to thousands per day) generated from many structurally diverse compounds (tens to hundreds per day) with a very quick turnaround time, in order to provide important activity and liability data to move discovery projects forward. Another important consideration for discovery bioanalysis is its fit-for-purpose quality requirement depending on the particular experiments being conducted at this stage, and it is usually not as stringent as those required in bioanalysis supporting drug development. These aforementioned attributes of HT discovery bioanalysis made it an ideal candidate for using software and automation tools to eliminate manual steps, remove bottlenecks, improve efficiency and reduce turnaround time while maintaining adequate quality. In this article we will review various recent developments that facilitate automation of individual bioanalytical procedures, such as sample preparation, MS/MS method development, sample analysis and data review, as well as fully integrated software tools that manage the entire bioanalytical workflow in HT discovery bioanalysis. In addition, software tools supporting the emerging high-resolution accurate MS bioanalytical approach are also discussed.
Collapse
|
33
|
Andersen D, Rasmussen B, Linnet K. Validation of a Fully Automated Robotic Setup for Preparation of Whole Blood Samples for LC-MS Toxicology Analysis. J Anal Toxicol 2012; 36:280-7. [DOI: 10.1093/jat/bks014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
34
|
Jiang H, Ouyang Z, Zeng J, Yuan L, Zheng N, Jemal M, Arnold ME. A User-Friendly Robotic Sample Preparation Program for Fully Automated Biological Sample Pipetting and Dilution to Benefit the Regulated Bioanalysis. ACTA ACUST UNITED AC 2012; 17:211-21. [DOI: 10.1177/2211068211429775] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Zhu P, Bowden P, Zhang D, Marshall JG. Mass spectrometry of peptides and proteins from human blood. MASS SPECTROMETRY REVIEWS 2011; 30:685-732. [PMID: 24737629 DOI: 10.1002/mas.20291] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2008] [Revised: 12/09/2009] [Accepted: 01/19/2010] [Indexed: 06/03/2023]
Abstract
It is difficult to convey the accelerating rate and growing importance of mass spectrometry applications to human blood proteins and peptides. Mass spectrometry can rapidly detect and identify the ionizable peptides from the proteins in a simple mixture and reveal many of their post-translational modifications. However, blood is a complex mixture that may contain many proteins first expressed in cells and tissues. The complete analysis of blood proteins is a daunting task that will rely on a wide range of disciplines from physics, chemistry, biochemistry, genetics, electromagnetic instrumentation, mathematics and computation. Therefore the comprehensive discovery and analysis of blood proteins will rank among the great technical challenges and require the cumulative sum of many of mankind's scientific achievements together. A variety of methods have been used to fractionate, analyze and identify proteins from blood, each yielding a small piece of the whole and throwing the great size of the task into sharp relief. The approaches attempted to date clearly indicate that enumerating the proteins and peptides of blood can be accomplished. There is no doubt that the mass spectrometry of blood will be crucial to the discovery and analysis of proteins, enzyme activities, and post-translational processes that underlay the mechanisms of disease. At present both discovery and quantification of proteins from blood are commonly reaching sensitivities of ∼1 ng/mL.
Collapse
Affiliation(s)
- Peihong Zhu
- Department of Chemistry and Biology, Ryerson University, 350 Victoria Street, Toronto, Ontario, Canada M5B 2K3
| | | | | | | |
Collapse
|
36
|
An automation-assisted generic approach for biological sample preparation and LC–MS/MS method validation. Bioanalysis 2011; 3:1975-86. [DOI: 10.4155/bio.11.178] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC–MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Results: Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Conclusion: Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.
Collapse
|
37
|
Liu G, Snapp HM, Ji QC. Internal standard tracked dilution to overcome challenges in dried blood spots and robotic sample preparation for liquid chromatography/tandem mass spectrometry assays. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:1250-1256. [PMID: 21488123 DOI: 10.1002/rcm.4990] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Dried blood spot (DBS) technology is an emerging alternative for sample collection in bioanalysis. Dilution for DBS samples is a challenge due to its solid sample format. Currently, DBS samples requiring dilution were first extracted as regular samples and then diluted with extracted blank samples containing internal standard (IS). Since the dilution step is a volume-critical step, extra care has to be taken to achieve accurate dilution when dealing with limited volume extracted samples. Here, we introduce an alternative sample dilution for liquid chromatography/tandem mass spectrometry (LC/MS/MS) assays using IS to track the dilution step. Dilution factor-adjusted IS working solution was first added to the sample requiring dilution before sample processing; subsequently, the processed sample was approximately diluted into the assay linear response range before LC/MS/MS analysis. We define this approach as "IS-tracked dilution". The advantage of this approach is that the diluting step is tracked by the IS and is no longer a volume-critical step. Another recognized challenge related to sample dilution is automatic sample dilution using a liquid handler. This "IS-tracked dilution" may also help address some of the challenges for automatic sample dilution of liquid samples. This new dilution approach was proven to be effective and convenient in both plasma assays and DBS assays using omeprazole as a probe compound.
Collapse
Affiliation(s)
- Guowen Liu
- Bioanalytical Sciences, Analytical and Bioanalytical Development, Bristol-Myers Squibb Co., Princeton, NJ 08543, USA.
| | | | | |
Collapse
|
38
|
Abstract
Bioanalysis usually requires a preparation procedure for sample cleanup or preconcentration. Conventional sample preparation techniques are often time consuming and labor intensive. Among recent progress in sample preparation, single drop microextraction (SDME) is one of the most efficient techniques providing both sample cleanup and preconcentration capabilities. In SDME, analytes are extracted from a sample solution into an acceptor drop and the drop is introduced to subsequent analysis. Since the volume of the acceptor drop is 1–10 µl or less, the consumption of solvents can be minimized and the preconcentration effect is enhanced. In this review, the basic principles of two-phase and three-phase SDME are described briefly and then recently developed modes of SDME, coupling with analytical instruments, and methods to enhance the drop stability are discussed. Recent applications of SDME to biological samples, including urine, blood and saliva, for the analysis of drugs, metal ions and biomarkers are reviewed.
Collapse
|
39
|
Bhambure R, Kumar K, Rathore AS. High-throughput process development for biopharmaceutical drug substances. Trends Biotechnol 2011; 29:127-35. [PMID: 21255855 DOI: 10.1016/j.tibtech.2010.12.001] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2010] [Revised: 11/24/2010] [Accepted: 12/02/2010] [Indexed: 10/18/2022]
Abstract
Quality by Design (QbD) is gaining industry acceptance as an approach towards development and commercialization of biotechnology therapeutic products that are expressed via microbial or mammalian cell lines. In QbD, the process is designed and controlled to deliver specified quality attributes consistently. To acquire the enhanced understanding that is necessary to achieve the above, however, requires more extensive experimentation to establish the design space for the process and the product. With biotechnology companies operating under ever-increasing pressure towards lowering the cost of manufacturing, the use of high-throughput tools has emerged as a necessary enabler of QbD in a time- and resource-constrained environment. We review this topic for those in academia and industry that are engaged in drug substance process development.
Collapse
Affiliation(s)
- Rahul Bhambure
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | | | | |
Collapse
|
40
|
Vogeser M, Kirchhoff F. Progress in automation of LC-MS in laboratory medicine. Clin Biochem 2011; 44:4-13. [DOI: 10.1016/j.clinbiochem.2010.06.005] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2010] [Revised: 06/01/2010] [Accepted: 06/08/2010] [Indexed: 11/15/2022]
|
41
|
Automated sample preparation for regulated bioanalysis: an integrated multiple assay extraction platform using robotic liquid handling. Bioanalysis 2010; 2:1023-40. [DOI: 10.4155/bio.10.55] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: A novel approach for regulated bioanalytical sample preparation has been developed to combine multiple types of extraction techniques into one integrated and automated sample-preparation suite that pairs a graphical user interface with the Hamilton Microlab® STAR robotic liquid handler. Results: The multi-assay sample-preparation suite is composed of three bioanalytical extraction techniques: protein precipitation, solid-phase extraction and liquid–liquid extraction. Validation data provided highly reproducible and robust results for each respective automated extraction technique. Conclusion: The user-friendly graphical user interface and modular method design provide a flexible and versatile approach for routine bioanalytical sample-preparation and is the first fully integrated multiple assay sample-preparation suite for regulated bioanalysis.
Collapse
|
42
|
Alley J, Bloom L, Kasaian M, Gao H, Berstein G, Clark JD, Miao W. A Human CXCL13-Induced Actin Polymerization Assay Measured by Fluorescence Plate Reader. Assay Drug Dev Technol 2010; 8:73-84. [DOI: 10.1089/adt.2008.0187] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Jennifer Alley
- Pfizer Inflammation and Immunology, Cambridge, Massachusetts
| | - Laird Bloom
- Pfizer Global Biotherapeutic Technologies, Cambridge, Massachusetts
| | - Marion Kasaian
- Pfizer Inflammation and Immunology, Cambridge, Massachusetts
| | - Huilan Gao
- Pfizer Global Biotherapeutic Technologies, Cambridge, Massachusetts
| | | | - James D. Clark
- Pfizer Inflammation and Immunology, Cambridge, Massachusetts
| | - Wenyan Miao
- Pfizer Inflammation and Immunology, Cambridge, Massachusetts
| |
Collapse
|
43
|
Durner J. Die klinische Chemie - Herausforderung der Medizin für die analytische Chemie und die Nanowissenschaften. Angew Chem Int Ed Engl 2009. [DOI: 10.1002/ange.200903363] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
44
|
Durner J. Clinical Chemistry: Challenges for Analytical Chemistry and the Nanosciences from Medicine. Angew Chem Int Ed Engl 2009; 49:1026-51. [DOI: 10.1002/anie.200903363] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
45
|
Nováková L, Vlčková H. A review of current trends and advances in modern bio-analytical methods: Chromatography and sample preparation. Anal Chim Acta 2009; 656:8-35. [DOI: 10.1016/j.aca.2009.10.004] [Citation(s) in RCA: 353] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2009] [Revised: 09/29/2009] [Accepted: 10/01/2009] [Indexed: 10/20/2022]
|
46
|
Abstract
This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. "Hyphenated" systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.
Collapse
Affiliation(s)
- Peter Schoenmakers
- Polymer Analysis Group, Faculty of Science, University of Amsterdam, 1018 WV Amsterdam, The Netherlands.
| |
Collapse
|
47
|
Gu P, Ding Y, Sun D, Hang T, Liu W, Ding L. Quantification of henatinib maleate, a novel potent inhibitor of VEGF receptors, in rat plasma by LC-MS/MS. Biomed Chromatogr 2009; 24:420-5. [DOI: 10.1002/bmc.1308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
48
|
Kay R, Barton C, Ratcliffe L, Matharoo-Ball B, Brown P, Roberts J, Teale P, Creaser C. Enrichment of low molecular weight serum proteins using acetonitrile precipitation for mass spectrometry based proteomic analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:3255-3260. [PMID: 18803344 DOI: 10.1002/rcm.3729] [Citation(s) in RCA: 124] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A rapid acetonitrile (ACN)-based extraction method has been developed that reproducibly depletes high abundance and high molecular weight proteins from serum prior to mass spectrometric analysis. A nanoflow liquid chromatography/tandem mass spectrometry (nano-LC/MS/MS) multiple reaction monitoring (MRM) method for 57 high to medium abundance serum proteins was used to characterise the ACN-depleted fraction after tryptic digestion. Of the 57 targeted proteins 29 were detected and albumin, the most abundant protein in serum and plasma, was identified as the 20th most abundant protein in the extract. The combination of ACN depletion and one-dimensional nano-LC/MS/MS enabled the detection of the low abundance serum protein, insulin-like growth factor-I (IGF-I), which has a serum concentration in the region of 100 ng/mL. One-dimensional sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) analysis of the depleted serum showed no bands corresponding to proteins of molecular mass over 75 kDa after extraction, demonstrating the efficiency of the method for the depletion of high molecular weight proteins. Total protein analysis of the ACN extracts showed that approximately 99.6% of all protein is removed from the serum. The ACN-depletion strategy offers a viable alternative to the immunochemistry-based protein-depletion techniques commonly used for removing high abundance proteins from serum prior to MS-based proteomic analyses.
Collapse
Affiliation(s)
- Richard Kay
- Quotient Bioresearch Ltd., Newmarket Road, Fordham CB7 5WW, UK.
| | | | | | | | | | | | | | | |
Collapse
|