1
|
Scott D, Clinton Frazee C, Garg U. Quantification of Phencyclidine (PCP) in Urine, Serum, or Plasma by Gas Chromatography-Mass Spectrometry (GC-MS). Methods Mol Biol 2024; 2737:405-412. [PMID: 38036841 DOI: 10.1007/978-1-0716-3541-4_37] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
Phencyclidine (PCP), a dissociative anesthetic, is a commonly abused recreational drug. In the 1950s, initially tested as an intravenous anesthetic, PCP was discontinued for clinical use due to its severe adverse effects. Since then, it has gained popularity as a recreational drug due to its ability to induce hallucinations and alter perception. PCP can be detected in urine, serum, or plasma by immunoassays and quantified and its presence confirmed by gas or liquid chromatography-mass spectrometry. In the method described here, a deuterated internal standard is added to the sample and the drug is extracted under alkaline conditions. Analysis is conducted using gas chromatography-mass spectrometry (GC-MS). Selected ion monitoring is used for quantitation of PCP.
Collapse
Affiliation(s)
- David Scott
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospital, Kansas City, MO, USA
| | - C Clinton Frazee
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospital, Kansas City, MO, USA
| | - Uttam Garg
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospital, Kansas City, MO, USA.
- University of Missouri School of Medicine, Kansas City, MO, USA.
| |
Collapse
|
2
|
Raju KSR, Taneja I, Singh SP, Wahajuddin. Utility of noninvasive biomatrices in pharmacokinetic studies. Biomed Chromatogr 2013; 27:1354-66. [PMID: 23939915 DOI: 10.1002/bmc.2996] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2013] [Revised: 06/12/2013] [Accepted: 06/13/2013] [Indexed: 12/31/2022]
Abstract
Blood and plasma are the biomatrices traditionally used for drug monitoring and their pharmacokinetic profiling. Blood is the circulating fluid in contact with all organs and tissues of body and thus is the most representative fluid for measuring systemic drug levels. However, venipuncture suffers from the caveat of being an invasive technique which often makes people reluctant to participate in clinical studies. Thus, there is a need for noninvasive bio-fluids that are ethically appropriate, cost-efficient and toxicologically relevant. These alternate bio-fluids may prove clinically useful as alternatives to plasma/serum in therapeutic drug monitoring, pharmacokinetic and toxicokinetic studies, doping control in sports medicine and to monitor local adverse effects. These may be of particular interest in the case of special population groups such as neonates, children, the elderly, terminally ill patients and pregnant or lactating women, and offer the advantage of circumvention of the demand for specialized personnel for sample collection. This review describes such noninvasive bio-fluids (saliva, sweat, tears and milk) that have been considered for pharmacokinetic drug analysis, emphasizing their sample preparation, its associated difficulties and their correlation with plasma.
Collapse
Affiliation(s)
- Kanumuri Siva Rama Raju
- Pharmacokinetics and Metabolism Division, CSIR-Central Drug Research Institute, Lucknow-226021, India
| | | | | | | |
Collapse
|
3
|
Kailasa SK, Wu HF. Recent Advances in Mass Spectrometry for the Identification of Neuro-chemicals and their Metabolites in Biofluids. Curr Neuropharmacol 2013; 11:436-64. [PMID: 24381533 PMCID: PMC3744906 DOI: 10.2174/1570159x11311040007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 04/05/2013] [Accepted: 04/09/2013] [Indexed: 11/22/2022] Open
Abstract
Recently, mass spectrometric related techniques have been widely applied for the identification and quantification of neurochemicals and their metabolites in biofluids. This article presents an overview of mass spectrometric techniques applied in the detection of neurological substances and their metabolites from biological samples. In addition, the advances of chromatographic methods (LC, GC and CE) coupled with mass spectrometric techniques for analysis of neurochemicals in pharmaceutical and biological samples are also discussed.
Collapse
Affiliation(s)
- Suresh Kumar Kailasa
- Department of Applied Chemistry, S. V. National Institute of Technology, Surat – 395007, India
| | - Hui-Fen Wu
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424, Taiwan
- School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, 800, Kaohsiung, Taiwan
- Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung, 80424, Taiwan
- Doctoral Degree Program in Marine Biotechnology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan
| |
Collapse
|
4
|
Oral fluid for the detection of drugs of abuse using immunoassay and LC–MS/MS. Bioanalysis 2013; 5:1555-69. [DOI: 10.4155/bio.13.115] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The utility of oral fluid as a sample matrix for the analysis of drugs has been increasing in popularity over the last few years. This is largely because of collection advantages over other matrices, but also due to the rapid improvements in analytical assays including highly sensitive liquid reagent format enzyme immunoassays and LC–MS/MS. This review will highlight improvements in assay formats, sensitivity, laboratory equipment and sample processing using low sample volumes to expand drug test profiles.
Collapse
|
5
|
Chimalakonda KC, Hailey C, Black R, Beekman A, Carlisle R, Lowman-Smith E, Singletary H, Owens SM, Hendrickson H. Development and validation of an LC-MS/MS method for determination of phencyclidine in human serum and its application to human drug abuse cases. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2010; 2:1249-1254. [PMID: 20959870 PMCID: PMC2955886 DOI: 10.1039/c0ay00206b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new analytical method was developed and validated for the rapid determination of phencyclidine (PCP) in human blood and serum. Rapid chromatographic separation decreased the analysis time relative to standard gas chromatography (GC)-based methodologies. The method involved the use of solid-phase extraction for sample preparation and cleanup followed by liquid chromatography tandem spectrometric (LC-MS/MS) analysis and an electrospray-ionization (ESI) interface. PCP was quantified using multiple-reaction-monitoring with deuterium labeled PCP (PCP-d(5)) as an internal standard. The method was validated for accuracy, precision, linearity, and recovery. The method was accurate with error <14% and precision with coefficient of variation (CV) <5.0%. The assay was linear over the entire range of calibration standards (r(2) > 0.997). The recovery of PCP after solid-phase extraction was greater than 90% with the lower limit of detection (LLOD) for PCP in 500 µl of human serum after solid-phase extraction at 0.06 ng ml(-1). This method was used to determine the levels of PCP in postmortem human blood samples. The LLOD in blood was 1 ng ml(-1). Blood PCP concentrations were also determined separately using GC and flame ionization detection (FID). Blood calibration standards and serum calibration standards yielded similar concentrations when used to quantitate authentic human blood samples that tested positive for PCP under the GC-FID method. Extraction of PCP from serum required fewer steps and therefore could be used as a calibration matrix in place of blood. The LC-MS/MS methodology shown here was higher throughput compared with GC-based methods because of very short chromatographic run times. This was accomplished without sacrificing analytical sensitivity.
Collapse
Affiliation(s)
- Krishna C. Chimalakonda
- Department of Pharmaceutical Sciences, College of Pharmacy, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| | - Chris Hailey
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Ryan Black
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Allison Beekman
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Rebecca Carlisle
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Elizabeth Lowman-Smith
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Heathe Singletary
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - S. Michael Owens
- Department of Pharmacology & Toxicology, College of Medicine, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| | - Howard Hendrickson
- Department of Pharmaceutical Sciences, College of Pharmacy, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| |
Collapse
|
6
|
Ferguson AM, Garg U. Quantitation of phencyclidine (PCP) in urine and blood using gas chromatography-mass spectrometry (GC-MS). Methods Mol Biol 2010; 603:461-467. [PMID: 20077098 DOI: 10.1007/978-1-60761-459-3_45] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Phencyclidine (PCP) is a cycloalkylamine and is classified as a dissociative anesthetic. In the 1950s, PCP was tested as an intravenous anesthetic but due to its severe side effects, it was withdrawn from the clinical use. Since then PCP has become an illegal street drug making its laboratory analysis forensically essential. PCP can be detected in urine, serum, or plasma by immunoassays and quantified by gas or liquid chromatography mass spectrometry. In the method described here, a deuterated internal standard is added to the sample and the drug is extracted under alkaline conditions. Analysis is conducted using gas chromatography mass spectrometry (GC-MS). Quantitation of PCP is done by comparing the responses of unknown samples to the standards using selected ion monitoring.
Collapse
Affiliation(s)
- Angela M Ferguson
- Department of Pathology and Laboratory Medicine, Children's Mercy Hospitals and Clinics, Kansas City, MO, USA
| | | |
Collapse
|
7
|
Abstract
Drug oral fluid analysis was first used almost 30 years ago for the purpose of therapeutic drug monitoring. Since then, oral fluid bioanalysis has become more popular, mainly in the fields of pharmacokinetics, workplace drug testing, criminal justice, driving under the influence testing and therapeutic drug monitoring. In fact, oral fluid can provide a readily available and noninvasive medium, without any privacy loss by the examinee, which occurs, for instance, during the collection of urine samples. It is believed that drug concentrations in oral fluid may parallel those measured in blood. This feature makes oral fluid an alternative analytical specimen to blood, which assumes particular importance in roadside testing, the most published application of this sample. Great improvements in the development of accurate and reliable methods for sample collection, in situ detection devices (on-site drug detection kits), and highly sensitive and specific analytical methods for oral fluid testing of drugs have been observed in the last few years. However, without mass spectrometry-based analytical methods, such as liquid chromatography coupled to mass spectrometry (LC–MS) or tandem mass spectrometry (LC–MS/MS), the desired sensitivity would not be met, due to the low amounts of sample usually available for analysis. This review will discuss a series of published papers on the applicability of oral fluid in the field of analytical, clinical and forensic toxicology, with a special focus on its advantages and drawbacks over the normally used biological specimens and the main technological advances over the last decade, which have made oral fluid analysis of drugs possible.
Collapse
|
8
|
Affiliation(s)
- T. A. Brettell
- Department of Chemical and Physical Sciences, Cedar Crest College, 100 College Drive, Allentown, Pennsylvania 18104-6196
| | - J. M. Butler
- Biochemical Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-8312
| | - J. R. Almirall
- Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, University Park, Miami, Florida 33199
| |
Collapse
|
9
|
Current Awareness in Drug Testing and Analysis. Drug Test Anal 2009. [DOI: 10.1002/dta.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
10
|
Mullangi R, Agrawal S, Srinivas NR. Measurement of xenobiotics in saliva: is saliva an attractive alternative matrix? Case studies and analytical perspectives. Biomed Chromatogr 2009; 23:3-25. [DOI: 10.1002/bmc.1103] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
11
|
|