1
|
Izarn O, Morin MP, Ntobe-Bunkete B, Golbin L, Ferrand-Sorre MJ, Tron C, Lemaitre F. Follow the Area Under the Curve Not the Trough Concentration: A Case Study of Tacrolimus Monitoring in a Kidney Transplant Recipient Cotreated With Phenobarbital. Ther Drug Monit 2024; 46:285-287. [PMID: 38648637 DOI: 10.1097/ftd.0000000000001203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/25/2024] [Indexed: 04/25/2024]
Abstract
ABSTRACT The authors described tacrolimus dosing in a kidney transplant patient concurrently treated with phenobarbital, where measuring the tacrolimus area under the curve was necessary to achieve adequate drug exposure and improve kidney function.
Collapse
Affiliation(s)
- Oscar Izarn
- Department of Biological Pharmacology, Hôpital Pontchaillou, Rennes University Hospital, Rennes, France
| | | | | | | | | | | | | |
Collapse
|
2
|
Ntobe-Bunkete B, Lemaitre F. Therapeutic drug monitoring in kidney and liver transplantation: current advances and future directions. Expert Rev Clin Pharmacol 2024; 17:505-514. [PMID: 38725273 DOI: 10.1080/17512433.2024.2354276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 05/08/2024] [Indexed: 05/24/2024]
Abstract
INTRODUCTION Immunosuppressive drugs (ISD) present a narrow therapeutic window and extremely high inter- and intra-individual pharmacokinetic variability, which complicates their use in solid organ transplant recipients. In order to find a narrow appropriate equilibrium for each patient with the aim of maintaining clinical efficacy and reducing the risk of adverse drug reactions, a complex both clinical and biological monitoring is required, in particular through the use of therapeutic drug monitoring (TDM). AREA COVERED This review provides an overview of the available information on the relationship between exposure to immunosuppressive drugs and their efficacy and/or toxicity in kidney and liver transplantation. The aim of the review is to describe the pharmacodynamic/pharmacokinetic relationship that exists for immunosuppressive drugs, to summarize the studies that assess the value of TDM for these drugs in clinical practice, and to present the target and monitoring strategies aimed at optimizing patient immunosuppression, which could help to take a step forward in the field of solid organ transplant patient care. EXPERT OPINION To improve the care of transplant patients, several TDM innovations can be pursued by investigators. Among these, the development of microsampling methods for TDM or the combination of pharmacodynamic biomarkers with ISD exposure measurements appear to be relevant strategies.
Collapse
Affiliation(s)
- Béni Ntobe-Bunkete
- Univ Rennes, CHU Rennes, EHESP, IRSET (Institut de Recherche en Santé, Environnement et Travail) - UMR S 1085, Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, Rennes, France
| | - Florian Lemaitre
- Univ Rennes, CHU Rennes, EHESP, IRSET (Institut de Recherche en Santé, Environnement et Travail) - UMR S 1085, Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, Rennes, France
- FHU SUPORT, Rennes, France
| |
Collapse
|
3
|
Zhao J, Setchell KD, Zhao X, Galandi S, Garr BN, Gao Z, Chin C, Stark S, Steele PE, Ryan TD. Use of volumetric absorptive microsampling and parallel reaction monitoring mass spectrometry for tacrolimus blood trough measurements at home in pediatric heart transplant patients. J Mass Spectrom Adv Clin Lab 2024; 31:1-7. [PMID: 38163003 PMCID: PMC10755538 DOI: 10.1016/j.jmsacl.2023.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/22/2023] [Accepted: 11/29/2023] [Indexed: 01/03/2024] Open
Abstract
Background Measurement of trough levels for calcineurin inhibitors by venipuncture sampling is a mainstay of patient management in solid organ transplant recipients but challenging in pediatric patients. Volumetric Absorptive Microsampling (VAMS) is a patient-friendly, minimally invasive sampling technique to accurately collect blood. An assay for measurement of tacrolimus in blood using VAMS, coupled with parallel reaction monitoring (PRM) mass spectrometry, was validated in pediatric heart transplant patients. Methods Tacrolimus was measured by a newly developed high-resolution PRM assay and compared with low-resolution tandem mass spectrometry (MRM). Dried blood samples were collected from pediatric heart transplant patients (n = 35) using VAMS devices and a satisfaction survey was completed by patients/guardians. Tacrolimus concentrations were compared across whole liquid blood, dried blood spots, and capillary blood, and shipping stability determined. Results The PRM assay was linear over a range 1-50 ng/mL, similar to MRM but had greater specificity due to reduced background noise. No significant differences in tacrolimus concentrations were observed between VAMS and venous blood. Tacrolimus dried on VAM tips was stable for 14 days and concentrations were unaffected by postal shipping. The variability in two simultaneously collected at-home patient samples was minimal - average concentration difference was 0.12 ± 0.94 ng/mL (p = 0.6) between paired samples. Conclusion A high resolution PRM mass spectrometry assay was developed for home-based dried blood collections for therapeutic monitoring of tacrolimus. The advantage of PRM was enhanced specificity and the VAMS devices provided a simple and convenient approach to blood sampling at home in pediatric heart transplant patients.
Collapse
Affiliation(s)
- Junfang Zhao
- Division of Pathology & Laboratory Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Kenneth D.R. Setchell
- Division of Pathology & Laboratory Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Xueheng Zhao
- Division of Pathology & Laboratory Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Stephanie Galandi
- Division of Pathology & Laboratory Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - BreAnn N Garr
- Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Zhiqian Gao
- Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Clifford Chin
- Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Shelly Stark
- Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Paul E. Steele
- Division of Pathology & Laboratory Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Thomas D. Ryan
- Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
4
|
Couette A, Tron C, Golbin L, Franck B, Houssel-Debry P, Frouget T, Morin MP, Brenier H, Rayar M, Verdier MC, Vigneau C, Chemouny J, Lemaitre F. Area under the curve of tacrolimus using microsampling devices: towards precision medicine in solid organ transplantation? Eur J Clin Pharmacol 2023; 79:1549-1556. [PMID: 37725122 DOI: 10.1007/s00228-023-03566-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 09/13/2023] [Indexed: 09/21/2023]
Abstract
PURPOSE Therapeutic drug monitoring of tacrolimus using trough concentration (Cmin) is mandatory to ensure drug efficacy and safety in solid organ transplantation. However, Cmin is just a proxy for the area under the curve of drug concentrations (AUC) which is the best pharmacokinetic parameter for exposure evaluation. Some studies suggest that patients may present discrepancies between these two parameters. AUC is now easily available through mini-invasive microsampling approach. The aim of this study is to evaluate the relationship between AUC and Cmin in patients benefiting from a complete pharmacokinetic profile using a microsampling approach. METHODS Fifty-one transplant recipients benefited from a complete pharmacokinetic profile using a microsampling approach, and their 24-h AUC were calculated using the trapezoidal method. The correlation with Cmin was then explored. In parallel, we estimated AUC using the sole Cmin and regression equations according to the post-transplantation days and the galenic form. RESULTS Weak correlations were found between 24-h AUC observed and the corresponding Cmin (R2 = 0.60) and between AUC observed and expected using the sole Cmin (R2 = 0.62). Therapeutic drug monitoring of tacrolimus using Cmin leads to over- or under-estimate drug exposure in 40.3% of patients. CONCLUSION Tacrolimus Cmin appears to be an imperfect reflection of drug exposure. Evaluating AUC using a microsampling approach offers a mini-invasive strategy to monitor tacrolimus treatment in transplant recipients.
Collapse
Affiliation(s)
- Aurélien Couette
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
| | - Camille Tron
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France
- FHU SUPORT, Rennes, F-35000, France
| | - Léonard Golbin
- FHU SUPORT, Rennes, F-35000, France
- Department of Nephrology, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Bénédicte Franck
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France
- FHU SUPORT, Rennes, F-35000, France
| | - Pauline Houssel-Debry
- Liver Disease Unit, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Thierry Frouget
- Department of Nephrology, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Marie-Pascale Morin
- Department of Nephrology, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Henri Brenier
- Department of Nephrology, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Michel Rayar
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France
- Liver Disease Unit, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Marie-Clémence Verdier
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France
- FHU SUPORT, Rennes, F-35000, France
| | - Cécile Vigneau
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- FHU SUPORT, Rennes, F-35000, France
- Department of Nephrology, Centre Hospitalier Universitaire de Rennes, F-35000 Rennes, France
| | - Jonathan Chemouny
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France
- FHU SUPORT, Rennes, F-35000, France
| | - Florian Lemaitre
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR S 1085, F-35000 Rennes, France.
- INSERM, Centre d'Investigation Clinique 1414, F-35000 Rennes, France.
- FHU SUPORT, Rennes, F-35000, France.
- Pharmacology Department, Hôpital Pontchaillou, CHU de Rennes, 2 rue Henri Le Guilloux, 35033 Rennes Cedex, France.
| |
Collapse
|
5
|
Nugraha RV, Yunivita V, Santoso P, Hasanah AN, Aarnoutse RE, Ruslami R. Analytical and Clinical Validation of Assays for Volumetric Absorptive Microsampling (VAMS) of Drugs in Different Blood Matrices: A Literature Review. Molecules 2023; 28:6046. [PMID: 37630297 PMCID: PMC10459922 DOI: 10.3390/molecules28166046] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 08/10/2023] [Accepted: 08/11/2023] [Indexed: 08/27/2023] Open
Abstract
Volumetric absorptive microsampling (VAMS) is the newest and most promising sample-collection technique for quantitatively analyzing drugs, especially for routine therapeutic drug monitoring (TDM) and pharmacokinetic studies. This technique uses an absorbent white tip to absorb a fixed volume of a sample (10-50 µL) within a few seconds (2-4 s), is more flexible, practical, and more straightforward to be applied in the field, and is probably more cost-effective than conventional venous sampling (CVS). After optimization and validation of an analytical method of a drug taken by VAMS, a clinical validation study is needed to show that the results by VAMS can substitute what is gained from CVS and to justify implementation in routine practice. This narrative review aimed to assess and present studies about optimization and analytical validation of assays for drugs taken by VAMS, considering their physicochemical drug properties, extraction conditions, validation results, and studies on clinical validation of VAMS compared to CVS. The review revealed that the bio-analysis of many drugs taken with the VAMS technique was optimized and validated. However, only a few clinical validation studies have been performed so far. All drugs that underwent a clinical validation study demonstrated good agreement between the two techniques (VAMS and CVS), but only by Bland-Altman analysis. Only for tacrolimus and mycophenolic acid were three measurements of agreement evaluated. Therefore, VAMS can be considered an alternative to CVS in routine practice, especially for tacrolimus and mycophenolic acid. Still, more extensive clinical validation studies need to be performed for other drugs.
Collapse
Affiliation(s)
- Rhea Veda Nugraha
- Doctoral Study Program, Faculty of Medicine, Universitas Padjadjaran, Bandung 40161, Indonesia;
| | - Vycke Yunivita
- Division of Pharmacology and Therapy, Department of Biomedical Sciences, Faculty of Medicine, Universitas Padjadjaran, Bandung 40161, Indonesia;
| | - Prayudi Santoso
- Division of Respirology and Critical Care, Department of Internal Medicine, Faculty of Medicine, Universitas Padjadjaran—Hasan Sadikin Hospital, Bandung 40161, Indonesia;
| | - Aliya Nur Hasanah
- Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Bandung 45363, Indonesia;
| | - Rob E. Aarnoutse
- Department of Pharmacy, Radboud University Medical Center, Research Institute for Medical Innovation, 6255 HB Nijmegen, The Netherlands;
| | - Rovina Ruslami
- Division of Pharmacology and Therapy, Department of Biomedical Sciences, Faculty of Medicine, Universitas Padjadjaran, Bandung 40161, Indonesia;
| |
Collapse
|
6
|
Golsanamlu Z, Soleymani J, Gharekhani A, Jouyban A. In-situ preparation of norepinephrine-functionalized silver nanoparticles and application for colorimetric detection of tacrolimus in plasma samples. Heliyon 2023; 9:e18404. [PMID: 37576308 PMCID: PMC10412875 DOI: 10.1016/j.heliyon.2023.e18404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 07/11/2023] [Accepted: 07/17/2023] [Indexed: 08/15/2023] Open
Abstract
Tacrolimus (Tac) is a well-documented immunosuppressive agent for the prevention of graft-vs-host diseases in several types of organ transplants. The narrow therapeutic window and the individual-variable pharmacokinetics of Tac demonstrate the importance of regular therapeutic drug monitoring (TDM) as an imperative concept for its oral medication regimens. A simple, one-step, selective, and sensitive colorimetric platform is fabricated for the determination of Tac by surface modification of the silver nanoparticles (AgNPs) via norepinephrine (NE) molecules. The attachment of NE and Tac induces the aggregation of the AgNPs, which is observed by color distinction (yellow to brown) and a noteworthy shifting of the absorption peak in the visible region. The fabricated nanoprobe can detect Tac concentrations in plasma samples in two linear ranges from 2 ng/mL to 70 ng/mL and 70 ng/mL to 1000 ng/mL with R2 > 0.99. The limit of detection (LOD) was calculated as low as 0.1 ng/mL. The developed method was applied for the determination of Tac in patient's plasma samples under Tac medication therapy.
Collapse
Affiliation(s)
- Zahra Golsanamlu
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Afshin Gharekhani
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Clinical Pharmacy (Pharmacotherapy), Faculty of Pharmacy, Sina Hospital, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Sciences Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Müller IR, Linden G, Charão MF, Antunes MV, Linden R. Dried blood spot sampling for therapeutic drug monitoring: challenges and opportunities. Expert Rev Clin Pharmacol 2023; 16:691-701. [PMID: 37300458 DOI: 10.1080/17512433.2023.2224562] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 06/08/2023] [Indexed: 06/12/2023]
Abstract
INTRODUCTION The use of dried blood spots (DBS) has gained interest in the field of therapeutic drug monitoring (TDM) due to its potential advantages, such as minimally invasive capillary blood collection, potential stabilization of drugs and metabolites at room or high temperatures, and lower biohazard, allowing for inexpensive storage and transportation. However, there are several drawbacks to the clinical use of DBS in TDM, mostly related to hematocrit (Hct) effects, differences between venous and capillary blood concentrations, among others, that must be evaluated during analytical and clinical method validation. AREA COVERED This review focuses on the most recent publications on the applications of DBS sampling for TDM (2016-2022), with a special focus on the challenges presented by this alternative sampling strategy, as well as the opportunities for clinical applications. Real-life studies presenting clinical applications were reviewed. EXPERT OPINION With the availability of method development and validation guidelines for DBS-based methods in TDM, higher levels of assay validation standardization have been achieved, expanding the clinical applications of DBS sampling in patient care. New sampling devices that overcome the limitations of classical DBS, such as the Hct effects, will further encourage the use of DBS in routine TDM.
Collapse
Affiliation(s)
| | - Gabriel Linden
- Laboratory of Analytical Toxicology, Universidade Feevale, Novo Hamburgo, Brazil
| | | | | | - Rafael Linden
- Laboratory of Analytical Toxicology, Universidade Feevale, Novo Hamburgo, Brazil
| |
Collapse
|
8
|
Applications of Volumetric Absorptive Microsampling Technique: A Systematic Critical Review. Ther Drug Monit 2023:00007691-990000000-00101. [PMID: 36917733 DOI: 10.1097/ftd.0000000000001083] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 11/19/2022] [Indexed: 03/16/2023]
Abstract
METHODS A novel microsampling device called Volumetric Absorptive microsampling (VAMS), developed in 2014, appears to have resolved the sample inhomogeneity inherent to dried blood spots, with improved precision in the volume of sample collected for measuring drug concentration. A literature search was conducted to identify several analytical and pharmacokinetic studies that have used VAMS in recent years. RESULTS The key factors for proper experimental design and optimization of the extraction of drugs and metabolites of interest from the device were summarized. This review focuses on VAMS and elaborates on bioanalytical factors, method validation steps, and scope of this technique in clinical practice. CONCLUSIONS The promising microsampling method VAMS is especially suited for conducting pharmacokinetic studies with very small volumes of blood, especially in special patient populations. Clinical validation of every VAMS assay must be conducted prior to the routine practical implementation of this method.
Collapse
|
9
|
Deprez S, Heughebaert L, Boffel L, Stove CP. Application of non-contact hematocrit prediction technologies to overcome hematocrit effects on immunosuppressant quantification from dried blood spots. Talanta 2023; 254:124111. [PMID: 36462285 DOI: 10.1016/j.talanta.2022.124111] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 11/12/2022] [Accepted: 11/15/2022] [Indexed: 11/21/2022]
Abstract
Fully automated dried blood spot (DBS) analysis for therapeutic drug monitoring (TDM) of the immunosuppressants tacrolimus, sirolimus, everolimus and cyclosporin A suffers from a so-called hematocrit (hct) effect. This effect is related to the analysis of a partial DBS punch and extractability differences imposed by blood with different hcts. As this is intrinsic to automated DBS analysis, this poses a serious drawback for accurate immunosuppressant quantification. Knowledge of a sample's hct allows to correct the derived immunosuppressant concentrations for this effect. Unfortunately, when using the DBS approach for sampling at patients' homes, this hct will typically not be available. The aim of this study was to investigate the validity of a correction algorithm during fully automated DBS analysis of immunosuppressants, based on knowledge of the DBS' hct, obtained via two distinct non-contact hematocrit prediction strategies, using either near-infrared (NIR) or ultra-violet/visible (UV/VIS) spectroscopy. For tacrolimus, sirolimus, everolimus, and cyclosporin A, 48, 47, 58 and 48 paired venous whole blood and venous DBS patient samples were collected, respectively, and analyzed using an automated DBS-MS 500 HCT extraction unit coupled to a liquid chromatography tandem mass spectrometry system. Additionally, for all 201 samples the hct of the DBS was predicted based on NIR and UV/VIS spectroscopy. For tacrolimus and cyclosporin A, both hct prediction strategies allowed for adequate correction of the hct effect. Also for sirolimus and everolimus the results greatly improved after hct correction, although a hct bias remained for sirolimus and for everolimus a slightly significant hct effect was observed after NIR- and UV/VIS-based correction. Application of both hct prediction strategies ensured that clinical acceptance limits (i.e. ≥ 80% of the samples within 20% difference compared to whole blood) were met for all analytes. In conclusion, we demonstrated that non-contact hct prediction strategies, applied in tandem with fully automated DBS analysis, can be used to adequately correct immunosuppressant concentrations, yielding a good agreement with whole blood.
Collapse
Affiliation(s)
- Sigrid Deprez
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
| | - Liesl Heughebaert
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
| | - Laura Boffel
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
| | - Christophe P Stove
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium.
| |
Collapse
|
10
|
Deprez S, Van Uytfanghe K, Stove CP. Liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring of immunosuppressants and creatinine from a single dried blood spot using the Capitainer® qDBS device. Anal Chim Acta 2023; 1242:340797. [PMID: 36657891 DOI: 10.1016/j.aca.2023.340797] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 12/12/2022] [Accepted: 01/02/2023] [Indexed: 01/09/2023]
Abstract
In recent years, a lot of attention has been given to a more patient-centric therapeutic drug monitoring (TDM) of immunosuppressant drugs (tacrolimus, sirolimus, everolimus and cyclosporin A) by the use of microsampling techniques. By adopting Dried Blood Spots (DBS) after a finger prick, instead of conventional venous blood draws, follow-up can (partially) be established from patients' homes. Despite the many advantages of DBS, one of the major disadvantages associated with this technique is the well described hematocrit (hct) effect. In order to overcome the hct area bias, different strategies have been proposed, amongst which the use of dried blood sampling techniques based on the volumetric collection of blood. The aim of this study was to evaluate the use of the Capitainer® qDBS (quantitative Dried Blood Spot) device for the combined TDM of four immunosuppressants and creatinine from a single qDBS. The set-up of an adequate sample preparation allowing both immunosuppressants and creatinine quantification was one of the key challenges in the method development due to device-specific interferences. Liquid chromatography tandem-mass spectrometry methods for the quantification of tacrolimus, sirolimus, everolimus, cyclosporin A and creatinine from qDBS (10 μL) were developed and validated based on international guidelines, also taking into account DBS-specific parameters. The methods proved to be accurate and reproducible, with absolute biases below 10% and within-run CVs (%) below 8% over a calibration range from 1 to 50 ng/mL for tacrolimus, sirolimus and everolimus, 20-1500 ng/mL for cyclosporin A, and 15-700 μmol/L for creatinine. Reproducible (CV < 15%) IS-compensated relative recovery values were obtained, showing no hematocrit-dependence (compared to a hct of 0.37), except for cyclosporin A at higher hct values. Application on venous blood left-over patient samples showed good agreement between the results of Capitainer® qDBS and whole blood with 98% (47/48), 93% (41/44), 89% (41/46), 88% (38/43) and 89% (116/131) of the samples lying within 20% of the whole blood result for tacrolimus, sirolimus, everolimus, cyclosporin A and plasma/serum for creatinine, respectively. For creatinine a blood/plasma ratio of 0.85 was found and used to convert qDBS results to plasma/serum results. As a next step, capillary finger prick samples will need to demonstrate the clinical applicability of the method in a real life setting.
Collapse
Affiliation(s)
- Sigrid Deprez
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
| | - Katleen Van Uytfanghe
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium; Ref4U - Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
| | - Christophe P Stove
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium.
| |
Collapse
|
11
|
First Experience of Optimization of Tacrolimus Therapeutic Drug Monitoring in a Patient Cotreated With Nirmatrelvir/Ritonavir: How Microsampling Approach Changes Everything. Transplantation 2023; 107:e68-e69. [PMID: 36696522 DOI: 10.1097/tp.0000000000004430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
12
|
Results From a Proficiency Testing Pilot for Immunosuppressant Microsampling Assays. Ther Drug Monit 2023; 45:61-68. [PMID: 35971674 PMCID: PMC9819198 DOI: 10.1097/ftd.0000000000001019] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 06/16/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Therapeutic drug monitoring (TDM) of immunosuppressive drugs is important for the prevention of allograft rejection in transplant patients. Several hospitals offer a microsampling service that provides patients the opportunity to sample a drop of blood from a fingerprick at home that can then be sent to the laboratory by mail. The aim of this study was to pilot an external quality control program. METHODS Fourteen laboratories from 7 countries participated (fully or partly) in 3 rounds of proficiency testing for the immunosuppressants tacrolimus, ciclosporin, everolimus, sirolimus, and mycophenolic acid. The microsampling devices included the following: Whatman 903 and DMPK-C, HemaXis, Mitra, and Capitainer-B. All assays were based on liquid chromatography with tandem mass spectrometry. In round 2, microsamples as well as liquid whole blood samples were sent, and 1 of these samples was a patient sample. RESULTS Imprecision CV% values for the tacrolimus microsamples reported by individual laboratories ranged from 13.2% to 18.2%, 11.7%-16.3%, and 12.2%-18.6% for rounds 1, 2, and 3, respectively. For liquid whole blood (round 2), the imprecision CV% values ranged from 3.9%-4.9%. For the other immunosuppressants, the results were similar. A great variety in analytical procedures was observed, especially the extraction method. For the patient sample, the microsample results led to different clinical decisions compared with that of the whole blood sample. CONCLUSIONS Immunosuppressant microsampling methods show great interlaboratory variation compared with whole blood methods. This variation can influence clinical decision-making. Thus, harmonization and standardization are needed. Proficiency testing should be performed regularly for laboratories that use immunosuppressant microsampling techniques in patient care.
Collapse
|
13
|
Deprez S, Stove CP. Dried blood microsampling-assisted therapeutic drug monitoring of immunosuppressants: An overview. J Chromatogr A 2023; 1689:463724. [PMID: 36592482 DOI: 10.1016/j.chroma.2022.463724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 12/12/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022]
Abstract
In the field of solid organ transplantation, chemotherapy and autoimmune disorders, treatment with immunosuppressant drugs requires intensive follow-up of the blood concentrations via therapeutic drug monitoring (TDM) because of their narrow therapeutic window and high intra- and inter-subject variability. This requires frequent hospital visits and venepunctures to allow the determination of these analytes, putting a high burden on the patients. In the context of patient-centric thinking, it is becoming increasingly established that at least part of these conventional blood draws could be replaced by microsampling, allowing home-sampling and increasing the quality of life for these patients. In this review we discuss the published methods - mostly using liquid chromatography coupled to tandem mass spectrometry - that have utilized (volumetric) dried blood samples as an alternative for conventional liquid whole blood for the TDM of immunosuppressant drugs. Furthermore, some pre-analytical considerations using DBS or volumetric alternatives are considered, as well as the applicability on clinical samples. The implementation status in clinical practice is also discussed, including (1) the cost-effectiveness of this approach compared to venepuncture, (2) the availability of multiplexed methods, (3) the status of harmonization and (4) patient perception. A brief perspective on potential future developments for the dried blood-based TDM of immunosuppressant drugs is provided, by considering how obstacles for the implementation of these strategies into clinical practice might be overcome.
Collapse
Affiliation(s)
- Sigrid Deprez
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium
| | - Christophe P Stove
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
| |
Collapse
|
14
|
Kocur A, Marszałek D, Rubik J, Czajkowska A, Pawiński T. Therapeutic Drug Monitoring of Tacrolimus Based on Volumetric Absorptive Microsampling Technique (VAMS) in Renal Transplant Pediatric Recipients-LC-MS/MS Method Development, Hematocrit Effect Evaluation, and Clinical Application. Pharmaceutics 2023; 15:pharmaceutics15010299. [PMID: 36678927 PMCID: PMC9864564 DOI: 10.3390/pharmaceutics15010299] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/09/2023] [Accepted: 01/12/2023] [Indexed: 01/19/2023] Open
Abstract
Tacrolimus (TAC) is post-transplant pharmacotherapy's most widely used immunosuppressant. In routine clinical practice, frequent uncomfortable venipuncture is necessary for whole-blood (WB) collection to check trough TAC levels. Volumetric absorptive microsampling (VAMS) is an alternative strategy to WB collection. In this study, we aimed to validate and develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for TAC quantification in WB and VAMS samples. After extraction with water and protein precipitation, the samples were directly analyzed using LC-MS/MS. Whole-blood and VAMS capillary-blood samples were collected from 50 patients treated with TAC during the follow-up visits. The cross-correlation between the developed methods was evaluated using Passing-Bablok regression and a Bland-Altman bias plot. The matrix effect (ME) and carry-over were insignificant for both scenarios. There was a high correlation between the processes and no significant clinical deviation. LC-MS/MS methods were successfully developed and validated in the 0.5-60 ng/mL calibration range. This study demonstrated and confirmed the utility of VAMS-based TAC monitoring in the pediatric population. This is the first study to directly develop and validate the VAMS LC-MS/MS method for evaluating the hematocrit effect in the pediatric population. The statistical correlation between immunochemical and VAMS-based methods was satisfactory.
Collapse
Affiliation(s)
- Arkadiusz Kocur
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
- Correspondence: ; Tel.: +48-22-572-06-35
| | - Dorota Marszałek
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
| | - Jacek Rubik
- Department of Nephrology, Kidney Transplantation and Arterial Hypertension, The Children’s Memorial Health Institute, Dzieci Polskich 20, 04-730 Warsaw, Poland
| | - Agnieszka Czajkowska
- Department of Biochemistry, Radioimmunology and Experimental Medicine, Pharmacokinetics Laboratory, The Children’s Memorial Health Institute, Dzieci Polskich 20, 04-730 Warsaw, Poland
| | - Tomasz Pawiński
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
| |
Collapse
|
15
|
Volumetric Absorptive Microsampling to Enhance the Therapeutic Drug Monitoring of Tacrolimus and Mycophenolic Acid: A Systematic Review and Critical Assessment. Ther Drug Monit 2023:00007691-990000000-00082. [PMID: 36728554 DOI: 10.1097/ftd.0000000000001066] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 10/23/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Volumetric absorptive microsampling (VAMS) is an emerging technique that may support multisample collection to enhance therapeutic drug monitoring in solid organ transplantation. This review aimed to assess whether tacrolimus and mycophenolic acid can be reliably assayed using VAMS and to identify knowledge gaps by providing granularity to existing analytical methods and clinical applications. METHODS A systematic literature search was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The PubMed, Embase, and Scopus databases were accessed for records from January 2014 to April 2022 to identify scientific reports on the clinical validation of VAMS for monitoring tacrolimus and mycophenolic acid concentrations. Data on the study population, sample sources, analytical methods, and comparison results were compiled. RESULTS Data from 12 studies were collected, including 9 studies pertaining to tacrolimus and 3 studies on the concurrent analysis of tacrolimus and mycophenolic acid. An additional 14 studies that provided information relevant to the secondary objectives (analytical validation and clinical application) were also included. The results of the clinical validation studies generally met the method agreement requirements described by regulatory agencies, but in many cases, it was essential to apply correction factors. CONCLUSIONSS Current evidence suggests that the existing analytical methods that use VAMS require additional optimization steps for the analysis of tacrolimus and mycophenolic acid. The recommendations put forth in this review can help guide future studies in achieving the goal of improving the care of transplant recipients by simplifying multisample collection for the dose optimization of these drugs.
Collapse
|
16
|
Kocur A, Pawiński T. Volumetric Absorptive Microsampling in Therapeutic Drug Monitoring of Immunosuppressive Drugs-From Sampling and Analytical Issues to Clinical Application. Int J Mol Sci 2022; 24:681. [PMID: 36614123 PMCID: PMC9821248 DOI: 10.3390/ijms24010681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/14/2022] [Accepted: 12/28/2022] [Indexed: 01/04/2023] Open
Abstract
Miniaturisation and simplification are novel approaches in clinical bioanalysis, especially in therapeutic drug monitoring (TDM). These contemporary trends are related to the sampling, pre-treatment, and analysis of biological fluids. Currently, dried blood spot (DBS), one of the most popular microsampling techniques, is feasible and inexpensive. However, obtaining reliable results with sample homogeneity and volume variability is difficult. Volumetric Absorptive Microsampling (VAMS) has recently enabled the accurate and precise collection of a fixed blood volume. It reduced the hematocrit effect, improved volumetric accuracy, and generated results correlating with the dose and drug exposure from wet blood. This review focuses on VAMS-Mitra™ devices, which have become increasingly important since 2014, mainly for TDM and toxicology studies. First, the current literature has been reviewed based on immunosuppressants and their determination in samples obtained using Mitra™. Second, the critical points, weaknesses, and strengths have been characterized in contrast to classic venipuncture and other microsampling methods. Finally, we indicate the points of attention according to the perspective of Mitra™ as well as its usefulness in clinical practice. VAMS is currently state-of-the-art in microsampling and seems to be a good instrument for improving adherence to immunosuppressive therapy, especially in the pediatric population.
Collapse
Affiliation(s)
| | - Tomasz Pawiński
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
| |
Collapse
|
17
|
A Volumetric Absorptive Microsampling UPLC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Mycophenolic Acid and Creatinine in Whole Blood of Renal Transplant Recipients. Pharmaceutics 2022; 14:pharmaceutics14122547. [PMID: 36559041 PMCID: PMC9788011 DOI: 10.3390/pharmaceutics14122547] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
(1) Background: Continuous monitoring of tacrolimus (TAC), mycophenolic acid (MPA), and creatinine (Cre) after renal transplantation is vitally important. In this study, we developed a new method based on volumetric absorptive microsampling (VAMS) combined with Ultra Performance Liquid Chromatography−Tandem Mass Spectrometry (UPLC-MS/MS) to simultaneously quantify three analytes including TAC, MPA, and Cre in whole blood. (2) Methods: The VAMS-based UPLC-MS/MS assay used a shared extraction and a single injection to simultaneously quantify the included TAC, MPA, and Cre. Development and validation were carried out following the Food and Drug Administration and European Medicines Agency guidelines for the validation of bioanalytical methods. Moreover, clinical validation for the three analytes was performed in both dried blood spot (DBS) and VAMS. Furthermore, a willingness survey was conducted using the system usability scale (SUS) for renal transplant recipients. (3) Results: The assay was successfully validated for all analytes. No interference, carryover, or matrix effects were observed, and extraction recoveries and process efficiencies were >90.00%. Analysis was unaffected by hematocrit (0.20~0.60, L/L) and anticoagulants (EDTA-2K). Dried VAMS samples were stable for 7 days at ambient temperature and stable for at least 1 month at −20 °C. During clinical validation, the measured TAC, corrected MPA, and Cre concentrations of VAMS samples met the analytical standards (95.00%, 88.57%, and 92.50%). When more stringent clinical acceptance criteria were set, the results obtained by VAMS (90.00%, 71.43%, and 85.00%) better than DBS (77.50%, 62.86%, and 70.00%). Compared with DBS, the survey found that renal transplant recipients are more inclined to use VAMS. (4) Conclusions: A robust extraction and UPLC-MS/MS analysis method in VAMS tips was developed and fully validated for the simultaneous quantification of TAC, MPA, and Cre concentrations. This method provides analytical support for the one-sample remote monitoring of both immunosuppressive drug concentrations and renal function in allo-renal recipients. Based on the good consistency between this method and the routine detection of venous blood samples and higher patient satisfaction than DBS, we believe that VAMS sampling can be a better alternative to venous whole-blood sampling.
Collapse
|
18
|
Zwart TC, Metscher E, van der Boog PJM, Swen JJ, de Fijter JW, Guchelaar H, de Vries APJ, Moes DJAR. Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients. Br J Clin Pharmacol 2022; 88:4854-4869. [PMID: 35670960 PMCID: PMC9796409 DOI: 10.1111/bcp.15433] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 05/20/2022] [Accepted: 05/25/2022] [Indexed: 01/01/2023] Open
Abstract
AIMS Immunosuppressant and kidney function monitoring are crucial for kidney transplant recipient follow-up. Microsamples enable remote sampling and minimise patient burden as compared to conventional venous sampling at the clinic. We developed a liquid chromatography-tandem mass spectrometry assay to quantify tacrolimus, mycophenolic acid (MPA), creatinine and iohexol in dried blood spot (DBS), and volumetric absorptive microsample (VAMS) samples. METHODS The assay was successfully validated analytically for all analytes. Clinical validation was conducted by direct comparison of paired DBS, VAMS and venous reference samples from 25 kidney transplant recipients. Patients received iohexol 5-15 minutes before immunosuppressant intake and were sampled 0, 1, 2 and 3 hours thereafter, enabling tacrolimus and MPA area under the concentration-time curve (AUC) and creatinine-based and iohexol-based glomerular filtration rate (GFR) estimation. Method agreement was evaluated using Passing-Bablok regression, Bland-Altman analysis and the percentages of values within 15-30% of the reference (P15 -P30 ) with a P20 acceptance threshold of 80%. RESULTS For DBS samples, method agreement was excellent for tacrolimus trough concentrations (n = 25, P15 = 92.0%) and AUCs (n = 25; P20 = 95.8%) and adequate for creatinine-based GFR trend monitoring (n = 25; P20 = 80%). DBS-based MPA AUC assessment showed suboptimal agreement (n = 16; P20 = 68.8%), but was considered acceptable given its P30 of 100%. The assay performed inadequately for DBS-based iohexol GFR determination (n = 24; P20 = 75%). The VAMS technique generally showed inferior performance, but can be considered for certain situations. CONCLUSION The assay was successfully validated for tacrolimus, MPA and creatinine quantification in DBS samples, enabling simultaneous remote kidney function trend monitoring and immunosuppressant therapeutic drug monitoring in kidney transplant recipients.
Collapse
Affiliation(s)
- Tom C. Zwart
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Erik Metscher
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Paul J. M. van der Boog
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Jesse J. Swen
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Johan W. de Fijter
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Henk‐Jan Guchelaar
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Aiko P. J. de Vries
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Dirk Jan A. R. Moes
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| |
Collapse
|
19
|
Leino AD, Takyi-Williams J, Wen B, Sun D, Pai MP. Application of a new volumetric microsampling device for quantitative bioanalysis of immunosuppression. Bioanalysis 2022; 14:1141-1152. [PMID: 36208082 PMCID: PMC9644239 DOI: 10.4155/bio-2022-0155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 09/22/2022] [Indexed: 11/17/2022] Open
Abstract
Background: Volumetric absorptive microsampling may reduce the blood collection burden associated with therapeutic drug monitoring of immunosuppression to prevent organ transplant rejection. This work describes the development of a laboratory and analytical technique for quantifying tacrolimus and mycophenolic acid (MPA) from the Tasso-M20™ in human whole blood using bead-based impact-assisted extraction. Results: The sampled blood volume was accurate with estimated volumes within <2% of the expected 20 μl. Recovery using impact-assisted extraction was 73-87% for MPA and 100% for tacrolimus and was hematocrit-independent for both analytes. The LC-MS/MS assay is precise and accurate within the acceptance criteria of 15%. Conclusion: The sampling and extraction procedures allowed for accurate quantification of tacrolimus and MPA. Exploration of abuse scenarios identified important education points for patients conducting home-based sample collections in the future.
Collapse
Affiliation(s)
- Abbie D Leino
- Department of Clinical Pharmacy, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
| | - John Takyi-Williams
- Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
| | - Bo Wen
- Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
| | - Duxin Sun
- Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Pharmaceutical Sciences, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
| | - Manjunath P Pai
- Department of Clinical Pharmacy, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
- Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
20
|
Yu KW, Li BL, Yuan YS, Liao JM, Li WK, Dong H, Ke PF, Jin X, Chen L, Zhao JJ, Wang H, Cao SW, Chen WY, Huang XZ, Zhao BB, Kang CM. A modified LC-MS/MS method for the detection of whole blood tacrolimus and its clinical value in Chinese kidney transplant patients. Heliyon 2022; 8:e10214. [PMID: 36042743 PMCID: PMC9420483 DOI: 10.1016/j.heliyon.2022.e10214] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/12/2022] [Accepted: 08/03/2022] [Indexed: 11/26/2022] Open
Abstract
Background For patients who treated with tacrolimus after kidney transplant, therapeutic drug monitoring is essential to improve their prognosis. However, previous detection methods have limitations, such as the overestimation and unacceptable bias in the immunoassays. Precision medicine has been challenged. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is recognized as the gold standard due to its accuracy and specificity, but lack of throughput and complex process limits its clinical application. Therefore, an accurate, simple and high throughput method for tacrolimus monitoring is needed for clinical practice. Methods A modified LC-MS/MS method was introduced and validated. Whole blood samples were prepared by a one-step protein precipitation method. Chromatographic separation was achieved using a Phenomenex Kinetex 2.6 μm XB-C18 2.1 × 50 mm column with a total run time of 3.5 min to avoid matrix effect. An electrospray ionization source (ESI) was used in positive ion multiple reaction monitoring (MRM) mode for mass spectrometric detection. In order to protect the mass spectrometer, only part of the sample after LC separation was allowed to enter the mass spectrum, through a two HPLC systems coupled one mass spectrometry design. In this way, the instrument throughput is also improved and realizing the detection of 2 samples within 3.5 min and carried out a shorter analyzing time for each sample of 1.75 min. Additionally, we calculated tacrolimus-intrapatient variant (Tac-IPV) based on this modified method and assessed the prognostic value of Tac-IPV in Chinese kidney transplant patients. Results The LC-MS/MS was modified by streamlining the procedure and increasing the throughput. The method proved to be accurate and reproducible with all performance parameters suitably meeting the clinical requirements over a calibration ranged from 0.37 to 42.90 ng/mL. Parameters such as linearity, limit of quantification (LoQ) and dilution integrity were validated with a clinical reportable range from 0.37 to 343.20 ng/mL, which was particularly useful for high drug concentrations patients (rare but very serious). Both cross-contamination and matrix effects were negligible. Clinical data of 83 patients showed that Tac-IPV was associated with poor kidney transplant outcome in Chinese (Hazard Ratio (HR) = 3.96, 4.75; 95% Cl: 1.10–14.21, 1.23–18.36; P < 0.05). Conclusions This modified LC-MS/MS method possessed high throughput and simple sample preparation, allowing it to meet daily clinical needs. At the same time, Tac-IPV based on this modified LC-MS/MS had excellent prognostic value in kidney transplantation. These advantages have great significance for the individualized treatment of Chinese kidney transplant patients and broad application of Tac-IPV.
Collapse
Affiliation(s)
- Ke-Wei Yu
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Bing-Ling Li
- Guangzhou KingMed Center for Clinical Laboratory Co., Ltd., KingMed College of Laboratory Medical of Guangzhou Medical University, Guangzhou, Guangdong 510120, China
| | - Ying-Shi Yuan
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Jia-Min Liao
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Wei-Kang Li
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Heng Dong
- Guangzhou KingMed Center for Clinical Laboratory Co., Ltd., KingMed College of Laboratory Medical of Guangzhou Medical University, Guangzhou, Guangdong 510120, China
| | - Pei-Feng Ke
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Xing Jin
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Lu Chen
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Jing-Jing Zhao
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, China
| | - Heng Wang
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Shun-Wang Cao
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Wei-Ye Chen
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China
| | - Xian-Zhang Huang
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China.,Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, Guangdong 510120, China
| | - Bei-Bei Zhao
- Guangzhou KingMed Center for Clinical Laboratory Co., Ltd., KingMed College of Laboratory Medical of Guangzhou Medical University, Guangzhou, Guangdong 510120, China
| | - Chun-Min Kang
- Department of Laboratory Medicine, Second Clinical Medical College, Guangzhou University of Traditional Chinese Medicine, China.,Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, Guangdong 510120, China
| |
Collapse
|
21
|
Ingle RG, Zeng S, Jiang H, Fang WJ. Current development of bioanalytical sample preparation techniques in pharmaceuticals. J Pharm Anal 2022; 12:517-529. [PMID: 36105159 PMCID: PMC9463481 DOI: 10.1016/j.jpha.2022.03.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 02/23/2022] [Accepted: 03/14/2022] [Indexed: 12/03/2022] Open
Abstract
Sample preparation is considered as the bottleneck step in bioanalysis because each biological matrix has its own unique challenges and complexity. Competent sample preparation to extract the desired analytes and remove redundant components is a crucial step in each bioanalytical approach. The matrix effect is a key hurdle in bioanalytical sample preparation, which has gained extensive consideration. Novel sample preparation techniques have advantages over classical techniques in terms of accuracy, automation, ease of sample preparation, storage, and shipment and have become increasingly popular over the past decade. Our objective is to provide a broad outline of current developments in various bioanalytical sample preparation techniques in chromatographic and spectroscopic examinations. In addition, how these techniques have gained considerable attention over the past decade in bioanalytical research is mentioned with preferred examples. Modern trends in bioanalytical sample preparation techniques, including sorbent-based microextraction techniques, are primarily emphasized. Bioanalytical sampling techniques are described with suitable applications in pharmaceuticals. The pros and cons of each bioanalytical sampling techniques are described. Relevant biological matrices are outlined.
Collapse
|
22
|
Tron C, Lemaitre F. Perspective on the Use of Limited Sampling Strategies to Assess Drug Exposure in the Era of Microsampling. Ther Drug Monit 2021; 43:812-813. [PMID: 34469418 DOI: 10.1097/ftd.0000000000000923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Camille Tron
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR, Rennes, France
- INSERM, Centre d'Investigation Clinique, Rennes, France
| | - Florian Lemaitre
- Univ Rennes, CHU Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail)-UMR, Rennes, France
- INSERM, Centre d'Investigation Clinique, Rennes, France
| |
Collapse
|