1
|
Schmidt L, Peterson K, Nunes TS, Knap M, Petrick L, Landero-Figueroa JA. A miniaturized sample preparation method for routine elemental determination in whole blood using volumetric absorptive micro-sampling by ICP-QQQ. Anal Bioanal Chem 2024; 416:2711-2724. [PMID: 37541974 DOI: 10.1007/s00216-023-04881-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/19/2023] [Accepted: 07/21/2023] [Indexed: 08/06/2023]
Abstract
Volumetric absorptive micro-sampling (VAMS) has emerged as a simple and safe tool for collecting and storing blood samples in clinical and bioanalytical fields. This study presents a novel method for determining essential and non-essential trace elements (As, Be, Cd, Cs, Cu, Fe, Mg, P, Pb, S, Sb, Se, Tl, V, U) in VAMS-collected blood samples using microwave-assisted digestion with diluted acid as sample preparation method and an inductively coupled plasma triple quadrupole mass spectrometry (ICP-QQQ) as determination technique. While certain elements posed challenges due to VAMS tip background issues (Al, Ti, Cr, Mn, Co, Ni, Sn, Mo, Ba), the method demonstrated high precision and accuracy for the targeted analytes. It was demonstrated that 4.5 mol L-1 HNO3 plus 100 µL H2O2 30% (w/w) was suitable for an efficiency of digestion for further elemental determination using micro-analysis (spending less than 300 µL analytical solution) by ICP-QQQ, given that the residual carbon content (RCC) after the digestion procedure was lower than 5%. All the results higher than limit of quantification (LOQ) were in agreement with reference values for all analytes. Accuracy was assessed through reference material analysis and recovery tests using spiked samples. Moreover, suitable agreements (p > 0.05) between this method (VAMS-M) and the comparative method (liquid sampling method) were obtained for all analytes >LOQ. Furthermore, all results >LOQ showed good precision according to precision requirements (Horwitz equation). In this way, with the use of dilute acid, low dilution factor (30-fold), and excellent digestion efficiency (>95%), the proposed method was able to achieve an excellent detection limit, precision, and accuracy for 15 elements: As, Be, Cd, Cs, Cu, Fe, Mg, P, Pb, S, Sb, Se, Tl, V, and U using ICP-MS/MS, without the need for matrix-matched calibration curves. This research showcases an innovative analytical approach using VAMS for blood samples, offering biosafety, practicality, sensitivity, versatility, and robustness. This method contributes to the advancement of trace element analysis in biomedical research and clinical applications.
Collapse
Affiliation(s)
- Lucas Schmidt
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - Kayla Peterson
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - Thieli Schaefer Nunes
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - Malgorzata Knap
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - Lauren Petrick
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - Julio Alberto Landero-Figueroa
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA.
| |
Collapse
|
2
|
Harahap Y, Salsabila S, Saputri FA. Development and validation of ivermectin quantification method in volumetric absorptive microsampling using liquid chromatography-tandem mass spectrometry. Heliyon 2024; 10:e29606. [PMID: 38665567 PMCID: PMC11044035 DOI: 10.1016/j.heliyon.2024.e29606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 03/14/2024] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
Background Ivermectin is a broad-spectrum anthelmintic used to control onchocerciasis from nematode parasites. As an anthelmintic, ivermectin is designed to have high levels in the gastrointestinal tract, so that the systemic intake is relatively low. Due to the very small concentration of ivermectin, a selective and sensitive approach is needed for the analysis of ivermectin in blood. Several methods have been developed using plasma and Dried Blood Spots, but there are still shortcomings due to hematocrit effects. Therefore, this study was conducted to establish a validated ivermectin analysis method with doramectin as the internal standard in using Ultra High-Performance Liquid Chromatography-Tandem Mass Spectrometry. Methods Mass spectrometry equipped with triple quadrupole and positive electrospray ionization mode was used to conduct the analysis. For the biological matrix, whole blood was used by Volumetric Absorptive Microsampling and extracted using a protein precipitation technique with a combination of acetonitrile and methanol (1:1). VAMS has some advantages such as not being affected by hematocrit, requires a small and fixed volume of sample, also a more efficient sampling process. Results The optimum conditions were achieved with an Acquity® UPLC BEH C18 column (1,7 μm; 2.1 × 100 mm); extracted-flow rate was 0,2 mL/min; mobile phase was 5 mM ammonium formate pH 3.00 and acetonitrile (10:90) with isocratic elution. Multiple Reaction Monitoring (MRM) detection by m/z values was 892.41 > 569.5 for ivermectin and 916,41 > 331,35 for doramectin. Conclusion The method has been appropriately validated in compliance with the 2018 guidelines laid out by the US Food and Drug Administration. Resulting the minimum detection (LLOQ) was 1 ng/mL with a linear concentration range spanning from 1 to 150 ng/mL.
Collapse
Affiliation(s)
- Yahdiana Harahap
- Faculty of Pharmacy, Universitas Indonesia, Depok, Indonesia
- Faculty of Military Pharmacy, Republic of Indonesia Defense University, Bogor, Indonesia
| | | | | |
Collapse
|
3
|
Ponzetto F, Parasiliti-Caprino M, Leoni L, Marinelli L, Nonnato A, Nicoli R, Kuuranne T, Ghigo E, Mengozzi G, Settanni F. LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling ( VAMS) for doping control purposes. Clin Chim Acta 2024; 557:117890. [PMID: 38537673 DOI: 10.1016/j.cca.2024.117890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/27/2024] [Accepted: 03/24/2024] [Indexed: 04/13/2024]
Abstract
BACKGROUND Volumetric Absorptive Microsampling (VAMS) is emerging as a valuable technique in the collection of dried biological specimens, offering a potential alternative to traditional sampling methods. The objective of this study was to assess the suitability of 30 μL VAMS for the measurement of endogenous steroid hormones. METHODS A novel LC-MS/MS method was developed for the quantification of 18 analytes in VAMS samples, including main endogenous free steroids and phase II metabolites of androgens. The method underwent validation in accordance with ISO/IEC 17025:2017 and World Anti-Doping Agency (WADA) requirements. Subsequently, it was applied to authentic VAMS samples obtained from 20 healthy volunteers to assess the stability of target analytes under varying storage conditions. RESULTS The validation protocol assessed method's selectivity, matrix effect, extraction recovery, quantitative performance, carry-over and robustness. The analysis of authentic samples demonstrated the satisfactory stability of monitored steroids in VAMS stored at room temperature, 4 °C, -20 °C and -80 °C for up to 100 days and subjected to up to 3 freezing-thawing cycles. CONCLUSIONS The validated LC-MS/MS method demonstrated its suitability for the measurement of steroids in dried blood VAMS. The observed stability of steroidal compounds suggests promising prospects for future applications of VAMS, both in anti-doping contexts and clinical research.
Collapse
Affiliation(s)
- Federico Ponzetto
- Division of Endocrinology, Diabetes and Metabolism, Department of Medical Sciences, University of Turin, Turin, Italy.
| | - Mirko Parasiliti-Caprino
- Division of Endocrinology, Diabetes and Metabolism, Department of Medical Sciences, University of Turin, Turin, Italy
| | - Laura Leoni
- Clinical Biochemistry Laboratory, Department of Medical Sciences, University of Turin, Turin, Italy
| | - Lorenzo Marinelli
- Division of Endocrinology, Diabetes and Metabolism, Department of Medical Sciences, University of Turin, Turin, Italy
| | - Antonello Nonnato
- Clinical Biochemistry Laboratory, Department of Medical Sciences, University of Turin, Turin, Italy
| | - Raul Nicoli
- Swiss Laboratory for Doping Analyses, University Center of Legal Medicine Geneva and Lausanne, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
| | - Tiia Kuuranne
- Swiss Laboratory for Doping Analyses, University Center of Legal Medicine Geneva and Lausanne, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
| | - Ezio Ghigo
- Division of Endocrinology, Diabetes and Metabolism, Department of Medical Sciences, University of Turin, Turin, Italy
| | - Giulio Mengozzi
- Clinical Biochemistry Laboratory, Department of Medical Sciences, University of Turin, Turin, Italy; Clinical Biochemistry Laboratory, City of Health and Science University Hospital, Turin, Italy
| | - Fabio Settanni
- Clinical Biochemistry Laboratory, City of Health and Science University Hospital, Turin, Italy
| |
Collapse
|
4
|
Breton A, Cirtiu CM, Muehlethaler C, Rudge J, Fleury N. Validation of Mitra ® VAMS® as a blood collection technique for trace elements analysis using ICP-MS/MS. Bioanalysis 2024; 16:203-217. [PMID: 38226838 DOI: 10.4155/bio-2023-0180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2024] Open
Abstract
Background: Clinical dosage of toxic and essential elements in blood is well established and the collection method is still by venipuncture. This method has drawbacks and is not suited for everyone. Volumetric absorptive microsampling (VAMS) has been shown to have advantages over venipuncture. Materials & methods: Using inductively coupled plasma tandem mass spectrometry, a method for quantifying elements in whole blood sampled on VAMS was developed/validated. Method's performance was assessed by comparison with whole blood results. Results: Validation and performance assessment tests tend to show that most of the targeted elements provides accurate and reproducible results comparing to a method of reference. Conclusion: Overall, VAMS presents good preliminary results to eventually become an alternative to venipuncture for blood sampling for some trace elements analysis purposes.
Collapse
Affiliation(s)
- Anthony Breton
- Institut National de Santé Publique du Québec (INSPQ), Centre de Toxicologie du Québec (CTQ), 945 Wolfe, Quebec, G1V 5B3, Canada
- Université du Québec à Trois-Rivières (UQTR), Department of Chemistry, Biochemistry & Physics, 3351 Boul. des Forges, Quebec, G9A 5H7, Canada
| | - Ciprian Mihai Cirtiu
- Institut National de Santé Publique du Québec (INSPQ), Centre de Toxicologie du Québec (CTQ), 945 Wolfe, Quebec, G1V 5B3, Canada
- Université du Québec à Trois-Rivières (UQTR), Department of Chemistry, Biochemistry & Physics, 3351 Boul. des Forges, Quebec, G9A 5H7, Canada
| | - Cyril Muehlethaler
- Université du Québec à Trois-Rivières (UQTR), Department of Chemistry, Biochemistry & Physics, 3351 Boul. des Forges, Quebec, G9A 5H7, Canada
| | - James Rudge
- Trajan Scientific & Medical, Crownhill Business Center, 14 Vincent Ave, Crownhill, Milton Keynes, MK8 0AB, UK
| | - Normand Fleury
- Institut National de Santé Publique du Québec (INSPQ), Centre de Toxicologie du Québec (CTQ), 945 Wolfe, Quebec, G1V 5B3, Canada
| |
Collapse
|
5
|
Vethe NT, Åsberg A, Andersen AM, Heier Skauby R, Bergan S, Midtvedt K. Clinical performance of volumetric finger-prick sampling for the monitoring of tacrolimus, creatinine and haemoglobin in kidney transplant recipients. Br J Clin Pharmacol 2023; 89:3690-3701. [PMID: 37537150 DOI: 10.1111/bcp.15870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/07/2023] [Accepted: 07/23/2023] [Indexed: 08/05/2023] Open
Abstract
AIMS Finger-prick sampling has emerged as an attractive tool for therapeutic drug monitoring and associated diagnostics. We aimed to validate the clinical performance of using two volumetric devices (Capitainer® qDBS and Mitra®) for monitoring tacrolimus, creatinine and haemoglobin in kidney transplant (KTx) recipients. Secondarily, we evaluated potential differences between finger-prick sampling performed by healthcare professionals vs. self-sampling, and differences between the two devices. METHODS We compared finger-prick and venous sampling in three settings: microsampling performed by healthcare personnel, self-sampling under supervision, unsupervised self-sampling. The finger-prick samples were analysed with adapted methods and results compared to routine method analysis of the venous blood samples. RESULTS Twenty-five KTx recipients completed the main study and 12 KTx recipients completed a post hoc validation study. For tacrolimus measurements and predicted area under the curve, the proportions within ±20% difference were 79%-96% for Capitainer and 77%-95% for Mitra. For creatinine and haemoglobin, the proportions within ±15% were 92%-100% and 93%-100% for Capitainer and 79%-96% and 67%-92% for Mitra, respectively. Comparing sampling situations, the success rate was consistent for Capitainer (92%-96%), whereas Mitra showed 72%-88% and 52%-72% success rates with samples collected by healthcare personnel and the patients themselves. CONCLUSIONS Capitainer and Mitra are technically feasible for measuring tacrolimus, creatinine and haemoglobin. In the context of self-sampling, Capitainer maintained consistent sampling success and analytical quality. Implementing volumetric finger-prick self-sampling for the monitoring of tacrolimus, creatinine and haemoglobin may simplify and improve the follow-up of KTx recipients.
Collapse
Affiliation(s)
- Nils Tore Vethe
- Department of Pharmacology, Oslo University Hospital, Oslo, Norway
| | - Anders Åsberg
- Department of Transplantation Medicine, Oslo University Hospital, Oslo, Norway
- Department of Pharmacy, University of Oslo, Oslo, Norway
| | | | | | - Stein Bergan
- Department of Pharmacology, Oslo University Hospital, Oslo, Norway
- Department of Pharmacy, University of Oslo, Oslo, Norway
| | - Karsten Midtvedt
- Department of Transplantation Medicine, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
6
|
Simeoli R, Cairoli S, Galaverna F, Becilli M, Boccieri E, Antonetti G, Vitale A, Mancini A, Rossi C, Vici CD, Goffredo BM. Utilization of volumetric absorptive microsampling and dried plasma spot for quantification of anti-fungal triazole agents in pediatric patients by using liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2023; 236:115688. [PMID: 37683371 DOI: 10.1016/j.jpba.2023.115688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 08/23/2023] [Accepted: 08/27/2023] [Indexed: 09/10/2023]
Abstract
BACKGROUND Recently, increasing attention has been paid to the use of microsampling techniques for therapeutic drug monitoring (TDM) in neonatal and pediatric populations. Volumetric Absorptive Microsampling (VAMS) has been introduced in the market under the name Mitra® (Neoteryx). These devices consist of porous absorbent tips that allow collection of fixed blood volumes (10-30 µL) to overcome the DBS-related hematocrit effect. Here, the authors analyzed the concentrations of triazole agents (voriconazole, posaconazole, and isavuconazole) in VAMS and dried plasma spot (DPS) samples. METHODS Fifty whole blood samples were obtained from pediatric patients subjected to systemic anti-fungal therapy. VAMS were collected by dipping the tip into whole blood before centrifugation for plasma recovery. Then, 30 µL of plasma was carefully spotted on filter paper to obtain DPS. Anti-fungal concentrations were measured using a validated LC-MS/MS kit (MassTox® Antimycotic Drugs/EXTENDED) provided by Chromsystems (Chromsystems Instruments & Chemicals). Drug concentrations in VAMS and DPS samples were compared to those in fresh plasma using Passing-Bablok and Bland-Altman tests. RESULTS Plasma concentrations of voriconazole, posaconazole, and isavuconazole were positively and significantly correlated with those obtained in VAMS and DPS samples (Spearman r range, 0.82-0.94, p < 0.001). Data were further analyzed using the Bland-Altman test, which showed a % mean difference compared to fresh plasma of -15.06-10.98 (range). The stability of both VAMS and DPS was ensured for at least 14 d at room temperature. CONCLUSIONS These results demonstrate that VAMS and DPS can be used for the TDM of anti-fungal agents. Owing to their stability, both sampling devices can be easily stored and shipped, without the need for refrigeration, to TDM laboratories that facilitate remote TDM applications. Finally, VAMS could be particularly suitable for pediatric and neonatal patients because they allow the collection of a few microliters of blood, thus improving ethical and compliance limitations.
Collapse
Affiliation(s)
- Raffaele Simeoli
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Sara Cairoli
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Federica Galaverna
- Department of Hematology/Oncology, Cell and Gene Therapy, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Marco Becilli
- Department of Hematology/Oncology, Cell and Gene Therapy, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Emilia Boccieri
- Department of Hematology/Oncology, Cell and Gene Therapy, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Giacomo Antonetti
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Alessia Vitale
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Alessandro Mancini
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Chiara Rossi
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Carlo Dionisi Vici
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Bianca Maria Goffredo
- Division of Metabolic Diseases and Drug Biology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy.
| |
Collapse
|
7
|
Kramer H, Bicer C, Otoul C, Rospo C, Macpherson M, Watling M, Bani M, Sciberras D, Chanteux H. Clinical Bridging Studies and Modeling Approach for Implementation of a Patient Centric Sampling Technique in Padsevonil Clinical Development. AAPS J 2023; 26:1. [PMID: 37973662 DOI: 10.1208/s12248-023-00866-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 10/03/2023] [Indexed: 11/19/2023] Open
Abstract
Volumetric absorptive microsampling (VAMS) techniques have gained popularity these last years as innovative tool for collection of blood pharmacokinetic (PK) samples in clinical trials as they offer many advantages over dried blood spot and conventional venous blood sampling. The use of Mitra®, a blood collection device based on volumetric absorptive microsampling (VAMS) technology, was implemented during clinical development of padsevonil (PSL), an anti-seizure medication (ASM) candidate. The present study describes the approach used to bridge plasma (obtained from conventional venous blood sampling) and blood exposures (obtained with Mitra®) to support the use of Mitra as sole blood PK sampling method in clinical trials. Paired blood (using Mitra®) and plasma samples (using conventional venous blood sampling) were collected in healthy volunteers as well as in patients with epilepsy. PSL concentration in plasma and blood were analyzed using different approaches which included evaluation of blood-to-plasma ratios (B/P) over time, linear regression, Bland-Altman analysis as well as development of a linear-mixed effect model based on clinical pharmacology studies. Results showed that the observed in vivo B/P and the measured bias between the 2 collection methods were consistent with the measured in vitro B/P. Graphical analysis demonstrated a clear time effect on the B/P which was confirmed in the linear mixed effect model with sampling time identified as significant covariate. Finally, the built-in model was validated using independent datasets and was shown to adequately predict plasma concentration based on blood concentration with a mean bias of less than 9% (predicted versus observed plasma concentration).
Collapse
Affiliation(s)
- Hester Kramer
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium
| | - Ceyhun Bicer
- BICER Consulting & Research BV, Antwerp, Belgium
| | - Christian Otoul
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium
| | - Chiara Rospo
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium
| | | | | | - Massimo Bani
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium
| | - David Sciberras
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium
| | - Hugues Chanteux
- Early Solutions, Development Sciences, UCB Biopharma SRL, Chemin du Foriest, B-1420, Braine l'Alleud, Belgium.
| |
Collapse
|
8
|
Kocur A, Rubik J, Czarnowski P, Czajkowska A, Marszałek D, Sierakowski M, Górska M, Pawiński T. Therapeutic drug monitoring of mycophenolic acid (MPA) using volumetric absorptive microsampling ( VAMS) in pediatric renal transplant recipients: ultra-high-performance liquid chromatography-tandem mass spectrometry analytical method development, cross-validation, and clinical application. Pharmacol Rep 2023:10.1007/s43440-023-00509-w. [PMID: 37452967 PMCID: PMC10374821 DOI: 10.1007/s43440-023-00509-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/03/2023] [Accepted: 07/04/2023] [Indexed: 07/18/2023]
Abstract
BACKGROUND Mycophenolic acid (MPA) is widely used in posttransplant pharmacotherapy for pediatric patients after renal transplantation. Volumetric absorptive microsampling (VAMS) is a recent approach for sample collection, particularly during therapeutic drug monitoring (TDM). The recommended matrix for MPA determination is plasma (PL), and conversion between capillary-blood VAMS samples and PL concentrations is required for the appropriate interpretation of the results. METHODS This study aimed to validate and develop a UHPLC-MS/MS method for MPA quantification in whole blood (WB), PL, and VAMS samples, with cross and clinical validation based on regression calculations. Methods were validated in the 0.10-15 µg/mL range for trough MPA concentration measurement according to the European Medicines Agency (EMA) guidelines. Fifty pediatric patients treated with MPA after renal transplantation were included in this study. PL and WB samples were obtained via venipuncture, whereas VAMS samples were collected after the fingerstick. The conversion from VAMSMPA to PLMPA concentration was performed using formulas based on hematocrit values and a regression model. RESULTS LC-MS/MS methods were successfully developed and validated according to EMA guidelines. The cross-correlation between the methods was evaluated using Passing-Bablok regression, Bland-Altman bias plots, and predictive performance calculations. Clinical validation of the developed method was successfully performed, and the formula based on regression was successfully validated for VAMSMPA to PLMPA concentration and confirmed on an independent group of samples. CONCLUSIONS This study is the first development of a triple matrix-based LC-MS/MS method for MPA determination in the pediatric population after renal transplantation. For the first time, the developed methods were cross-validated with routinely used HPLC-DAD protocol.
Collapse
Affiliation(s)
- Arkadiusz Kocur
- Department of Drug Chemistry, Medical University of Warsaw, 1 Banacha St, 02-091, Warsaw, Poland.
- Pharmacokinetics Laboratory, Department of Biochemistry, Radioimmunology, and Experimental Medicine, The Children's Memorial Health Institute, Dzieci Polskich 20, 04-730, Warsaw, Poland.
| | - Jacek Rubik
- Department of Nephrology, Kidney Transplantation, and Arterial Hypertension, The Children's Memorial Health Institute, Dzieci Polskich 20, 04-730, Warsaw, Poland
| | - Paweł Czarnowski
- Department of Genetics, Maria Sklodowska-Curie National Research Institute of Oncology, Roentgena 5, 02-781, Warsaw, Poland
| | - Agnieszka Czajkowska
- Pharmacokinetics Laboratory, Department of Biochemistry, Radioimmunology, and Experimental Medicine, The Children's Memorial Health Institute, Dzieci Polskich 20, 04-730, Warsaw, Poland
| | - Dorota Marszałek
- Department of Drug Chemistry, Medical University of Warsaw, 1 Banacha St, 02-091, Warsaw, Poland
| | - Maciej Sierakowski
- Institute of Biological Sciences, Cardinal Stefan Wyszynski University, 1/3 Kazimierza Wóycickiego St, 01-938, Warsaw, Poland
| | - Marta Górska
- Pharmacokinetics Laboratory, Department of Biochemistry, Radioimmunology, and Experimental Medicine, The Children's Memorial Health Institute, Dzieci Polskich 20, 04-730, Warsaw, Poland
| | - Tomasz Pawiński
- Department of Drug Chemistry, Medical University of Warsaw, 1 Banacha St, 02-091, Warsaw, Poland
| |
Collapse
|
9
|
Kapadnis U, Locuson C, Okamura H, Rienzo GD, Cotter C, Zhu D, Narayanaswami R, Castro-Perez J, Marathe P, Yang WC. Volumetric absorptive microsampling as an effective microsampling technique for LC-MS/MS bioanalysis of biomarkers in drug discovery. Bioanalysis 2023; 15:845-859. [PMID: 37305945 DOI: 10.4155/bio-2023-0059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023] Open
Abstract
Aim: Develop and validate a volumetric absorptive microsampling (VAMS)-based LC-MS/MS method to support the bioanalysis of amino acid and carboxylic acid biomarkers in mouse whole blood. Method: Mouse whole blood was collected using a 10 μl VAMS device. The analytes in VAMS were extracted and analyzed using an LC-MS/MS method. Results: The VAMS-based LC-MS/MS assay exhibited a linearity range of 10.0-10,000 ng/ml with acceptable precision and accuracy and consistent recovery. The analyte stability in mouse whole blood VAMS was shown for 7 days at ambient conditions and at -80°C, as well as with three freeze/thaw cycles. Conclusion: A simple and robust VAMS-based LC-MS/MS method was developed and further validated for simultaneous bioanalysis of nine biomarkers in mouse whole blood.
Collapse
Affiliation(s)
| | - Chuck Locuson
- Agios Pharmarceuticals, 88 Sidney St, Cambridge, MA 02139, USA
| | - Heidi Okamura
- Agios Pharmarceuticals, 88 Sidney St, Cambridge, MA 02139, USA
| | | | - Cece Cotter
- Agios Pharmarceuticals, 88 Sidney St, Cambridge, MA 02139, USA
| | - Dongwei Zhu
- Servier Pharmaceuticals, 200 Pier 4 Blvd., Boston, MA 02210, USA
| | | | | | - Punit Marathe
- Agios Pharmarceuticals, 88 Sidney St, Cambridge, MA 02139, USA
| | - Wen-Chu Yang
- NovaBioAssays, 52 Dragon CT, Suite 3B, Woburn, MA 01801, USA
| |
Collapse
|
10
|
Harahap Y, Noer RF, Simorangkir TPH. Development and validation of method for analysis of favipiravir and remdesivir in volumetric absorptive microsampling with ultra high-performance liquid chromatography-tandem mass spectrophotometry. Front Med (Lausanne) 2023; 10:1022605. [PMID: 37228397 PMCID: PMC10203959 DOI: 10.3389/fmed.2023.1022605] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 02/27/2023] [Indexed: 05/27/2023] Open
Abstract
Favipiravir and remdesivir are drugs to treat COVID-19. This study aims to find an optimum and validated method for simultaneous analysis of favipiravir and remdesivir in Volumetric Absorptive Microsampling (VAMS) by Ultra High-Performance Liquid Chromatography-Tandem Mass Spectrophotometry. The use of VAMS can be an advantage because the volume of blood is small and the sample preparation process is simple. Sample preparation was done by precipitation of protein using 500 μL of methanol. Analysis was carried out by ultra high-performance liquid chromatography-tandem mass spectrophotometry with ESI+ and MRM with m/z 157.9 > 112.92 for favipiravir, 603.09 > 200.005 for remdesivir, and at m/z 225.968 > 151.991 for acyclovir as the internal standard. The separation was carried out using an Acquity UPLC BEH C18 column (100 × 2.1 mm; 1.7 m), 0.2% formic acid-acetonitrile (50:50), flow rate was 0.15 mL/min, and column temperature was 50°C. The analytical method has been validated with the requirements issued by the Food and Drug Administration (2018) and European Medicine Agency (2011). The calibration range of favipiravir is 0.5-160 μg/mL and 0.002-8 μg/mL for remdesivir.
Collapse
Affiliation(s)
- Yahdiana Harahap
- Faculty of Pharmacy, Universitas Indonesia, Depok, Indonesia
- Pharmacy Study Program, Faculty of Medicine and Health Sciences, the Republic of Indonesia Defense University, Bogor, Indonesia
| | | | - Timbul Partogi H. Simorangkir
- Pharmacy Study Program, Faculty of Medicine and Health Sciences, the Republic of Indonesia Defense University, Bogor, Indonesia
| |
Collapse
|
11
|
Volani C, Malfertheiner C, Caprioli G, Fjelstrup S, Pramstaller PP, Rainer J, Paglia G. VAMS-Based Blood Capillary Sampling for Mass Spectrometry-Based Human Metabolomics Studies. Metabolites 2023; 13:metabo13020146. [PMID: 36837765 PMCID: PMC9958641 DOI: 10.3390/metabo13020146] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/14/2023] [Accepted: 01/15/2023] [Indexed: 01/20/2023] Open
Abstract
Volumetric absorptive microsampling (VAMS) is a recently developed sample collection method that enables single-drop blood collection in a minimally invasive manner. Blood biomolecules can then be extracted and processed for analysis using several analytical platforms. The integration of VAMS with conventional mass spectrometry (MS)-based metabolomics approaches is an attractive solution for human studies representing a less-invasive procedure compared to phlebotomy with the additional potential for remote sample collection. However, as we recently demonstrated, VAMS samples require long-term storage at -80 °C. This study investigated the stability of VAMS samples during short-term storage and compared the metabolome obtained from capillary blood collected from the fingertip to those of plasma and venous blood from 22 healthy volunteers. Our results suggest that the blood metabolome collected by VAMS samples is stable at room temperature only for up to 6 h requiring subsequent storage at -80 °C to avoid significant changes in the metabolome. We also demonstrated that capillary blood provides better coverage of the metabolome compared to plasma enabling the analysis of several intracellular metabolites presented in red blood cells. Finally, this work demonstrates that with the appropriate pre-analytical protocol capillary blood can be successfully used for untargeted metabolomics studies.
Collapse
Affiliation(s)
- Chiara Volani
- Institute for Biomedicine, Affiliated to the University of Lübeck, Eurac Research, 39100 Bolzano, Italy
| | - Christa Malfertheiner
- Institute for Biomedicine, Affiliated to the University of Lübeck, Eurac Research, 39100 Bolzano, Italy
| | - Giulia Caprioli
- Institute for Biomedicine, Affiliated to the University of Lübeck, Eurac Research, 39100 Bolzano, Italy
| | - Søren Fjelstrup
- Interdisciplinary Nanoscience Center, Aarhus University, 8000 Aarhus, Denmark
| | - Peter P. Pramstaller
- Institute for Biomedicine, Affiliated to the University of Lübeck, Eurac Research, 39100 Bolzano, Italy
| | - Johannes Rainer
- Institute for Biomedicine, Affiliated to the University of Lübeck, Eurac Research, 39100 Bolzano, Italy
| | - Giuseppe Paglia
- School of Medicine and Surgery, University of Milano-Bicocca, 20854 Vedano al Lambro, Italy
- Correspondence:
| |
Collapse
|
12
|
Kocur A, Marszałek D, Rubik J, Czajkowska A, Pawiński T. Therapeutic Drug Monitoring of Tacrolimus Based on Volumetric Absorptive Microsampling Technique ( VAMS) in Renal Transplant Pediatric Recipients-LC-MS/MS Method Development, Hematocrit Effect Evaluation, and Clinical Application. Pharmaceutics 2023; 15:pharmaceutics15010299. [PMID: 36678927 PMCID: PMC9864564 DOI: 10.3390/pharmaceutics15010299] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/09/2023] [Accepted: 01/12/2023] [Indexed: 01/19/2023] Open
Abstract
Tacrolimus (TAC) is post-transplant pharmacotherapy's most widely used immunosuppressant. In routine clinical practice, frequent uncomfortable venipuncture is necessary for whole-blood (WB) collection to check trough TAC levels. Volumetric absorptive microsampling (VAMS) is an alternative strategy to WB collection. In this study, we aimed to validate and develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for TAC quantification in WB and VAMS samples. After extraction with water and protein precipitation, the samples were directly analyzed using LC-MS/MS. Whole-blood and VAMS capillary-blood samples were collected from 50 patients treated with TAC during the follow-up visits. The cross-correlation between the developed methods was evaluated using Passing-Bablok regression and a Bland-Altman bias plot. The matrix effect (ME) and carry-over were insignificant for both scenarios. There was a high correlation between the processes and no significant clinical deviation. LC-MS/MS methods were successfully developed and validated in the 0.5-60 ng/mL calibration range. This study demonstrated and confirmed the utility of VAMS-based TAC monitoring in the pediatric population. This is the first study to directly develop and validate the VAMS LC-MS/MS method for evaluating the hematocrit effect in the pediatric population. The statistical correlation between immunochemical and VAMS-based methods was satisfactory.
Collapse
Affiliation(s)
- Arkadiusz Kocur
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
- Correspondence: ; Tel.: +48-22-572-06-35
| | - Dorota Marszałek
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
| | - Jacek Rubik
- Department of Nephrology, Kidney Transplantation and Arterial Hypertension, The Children’s Memorial Health Institute, Dzieci Polskich 20, 04-730 Warsaw, Poland
| | - Agnieszka Czajkowska
- Department of Biochemistry, Radioimmunology and Experimental Medicine, Pharmacokinetics Laboratory, The Children’s Memorial Health Institute, Dzieci Polskich 20, 04-730 Warsaw, Poland
| | - Tomasz Pawiński
- Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
| |
Collapse
|
13
|
Kocur A, Pawiński T. Volumetric Absorptive Microsampling in Therapeutic Drug Monitoring of Immunosuppressive Drugs-From Sampling and Analytical Issues to Clinical Application. Int J Mol Sci 2022; 24:ijms24010681. [PMID: 36614123 PMCID: PMC9821248 DOI: 10.3390/ijms24010681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/14/2022] [Accepted: 12/28/2022] [Indexed: 01/04/2023] Open
Abstract
Miniaturisation and simplification are novel approaches in clinical bioanalysis, especially in therapeutic drug monitoring (TDM). These contemporary trends are related to the sampling, pre-treatment, and analysis of biological fluids. Currently, dried blood spot (DBS), one of the most popular microsampling techniques, is feasible and inexpensive. However, obtaining reliable results with sample homogeneity and volume variability is difficult. Volumetric Absorptive Microsampling (VAMS) has recently enabled the accurate and precise collection of a fixed blood volume. It reduced the hematocrit effect, improved volumetric accuracy, and generated results correlating with the dose and drug exposure from wet blood. This review focuses on VAMS-Mitra™ devices, which have become increasingly important since 2014, mainly for TDM and toxicology studies. First, the current literature has been reviewed based on immunosuppressants and their determination in samples obtained using Mitra™. Second, the critical points, weaknesses, and strengths have been characterized in contrast to classic venipuncture and other microsampling methods. Finally, we indicate the points of attention according to the perspective of Mitra™ as well as its usefulness in clinical practice. VAMS is currently state-of-the-art in microsampling and seems to be a good instrument for improving adherence to immunosuppressive therapy, especially in the pediatric population.
Collapse
|
14
|
Wang X, Dai X, Wan S, Fan Y, Wu L, Xu H, Yan L, Gong X, Li Y, Luo Y, Bai Y, Li Y. A Volumetric Absorptive Microsampling UPLC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Mycophenolic Acid and Creatinine in Whole Blood of Renal Transplant Recipients. Pharmaceutics 2022; 14. [PMID: 36559041 DOI: 10.3390/pharmaceutics14122547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
(1) Background: Continuous monitoring of tacrolimus (TAC), mycophenolic acid (MPA), and creatinine (Cre) after renal transplantation is vitally important. In this study, we developed a new method based on volumetric absorptive microsampling (VAMS) combined with Ultra Performance Liquid Chromatography−Tandem Mass Spectrometry (UPLC-MS/MS) to simultaneously quantify three analytes including TAC, MPA, and Cre in whole blood. (2) Methods: The VAMS-based UPLC-MS/MS assay used a shared extraction and a single injection to simultaneously quantify the included TAC, MPA, and Cre. Development and validation were carried out following the Food and Drug Administration and European Medicines Agency guidelines for the validation of bioanalytical methods. Moreover, clinical validation for the three analytes was performed in both dried blood spot (DBS) and VAMS. Furthermore, a willingness survey was conducted using the system usability scale (SUS) for renal transplant recipients. (3) Results: The assay was successfully validated for all analytes. No interference, carryover, or matrix effects were observed, and extraction recoveries and process efficiencies were >90.00%. Analysis was unaffected by hematocrit (0.20~0.60, L/L) and anticoagulants (EDTA-2K). Dried VAMS samples were stable for 7 days at ambient temperature and stable for at least 1 month at −20 °C. During clinical validation, the measured TAC, corrected MPA, and Cre concentrations of VAMS samples met the analytical standards (95.00%, 88.57%, and 92.50%). When more stringent clinical acceptance criteria were set, the results obtained by VAMS (90.00%, 71.43%, and 85.00%) better than DBS (77.50%, 62.86%, and 70.00%). Compared with DBS, the survey found that renal transplant recipients are more inclined to use VAMS. (4) Conclusions: A robust extraction and UPLC-MS/MS analysis method in VAMS tips was developed and fully validated for the simultaneous quantification of TAC, MPA, and Cre concentrations. This method provides analytical support for the one-sample remote monitoring of both immunosuppressive drug concentrations and renal function in allo-renal recipients. Based on the good consistency between this method and the routine detection of venous blood samples and higher patient satisfaction than DBS, we believe that VAMS sampling can be a better alternative to venous whole-blood sampling.
Collapse
|
15
|
Johnson R, Rehmani I, Leahy M, Walker A, Liang X, Dean B, Wang J. Volumetric absorptive microsampling-LC-MS/MS assays for quantitation of giredestrant in dried human whole blood. Bioanalysis 2022; 14:1377-89. [PMID: 36655682 DOI: 10.4155/bio-2022-0189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Volumetric absorption microsampling devices offer minimally invasive and user-friendly collection of capillary blood in volumes as low as 10 μl. Herein we describe the assay validation for determination of the selective estrogen receptor degrader giredestrant (GDC-9545) in dried human whole blood collected using the Mitra® and Tasso-M20 devices. Both LC-MS/MS assays met validation acceptance criteria for the linear range 1-1000 ng/ml giredestrant. Mitra and Tasso-M20 samples were stable for 84 and 28 days at ambient conditions, respectively, and for 7-9 days at 40 and -70°C. Blood hematocrit, hyperlipidemia and anticoagulant did not impact quantitation of giredestrant. These validated assays are suitable for the determination of giredestrant in dried blood samples collected using Mitra and Tasso-M20 microsampling devices.
Collapse
|
16
|
Daraghmeh DN, Moghaddami M, Bobrovskaya L, Proudman SM, Wiese MD. Quantitation of methotrexate polyglutamates in human whole blood, erythrocytes and leukocytes collected via venepuncture and volumetric absorptive micro-sampling: a green LC-MS/MS-based method. Anal Bioanal Chem 2022; 414:6029-6046. [PMID: 35796782 PMCID: PMC9314280 DOI: 10.1007/s00216-022-04186-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 05/29/2022] [Accepted: 06/17/2022] [Indexed: 11/01/2022]
Abstract
Low-dose methotrexate (MTX) plays a key role in treatment of rheumatoid arthritis. However, not all patients respond satisfactorily, and no therapeutic drug monitoring has been implemented in clinical practice, despite the fact that MTX therapy has now been available for decades. Analysis of individual intracellular MTX metabolites among rheumatoid arthritis (RA) patients is hampered by the low intracellular concentrations of MTX-PGs which require a highly sensitive method to quantify. Here, we present a rapid and highly sensitive LC (HILIC) MS/MS method with LLOQ 0.1 nM, 0.8 nmol/L for each metabolite of MTX-PG1-5 and MTX-PG6-7 respectively. Over a linear range of 0.1-100 nM, 0.8-100 nmol/L for each metabolite of MTX-PG1-5 and MTX-PG6-7, respectively, the inter- and intra- accuracy and precision were within 15% of the nominal value for all MTX metabolites. The presented assay was used to assess and compare MTX metabolite concentrations extracted from four different matrices: red blood cells, plasma, peripheral blood mononuclear cells, and whole blood that have been collected either using traditional venepuncture or volumetric absorptive micro-sampling (VAMS) sampling techniques. The presented method not only improves analyte coverage and sensitivity as compared to other published methods; it also improves the greenness.
Collapse
Affiliation(s)
- Dala N Daraghmeh
- Centre for Pharmaceutical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, GPO Box 2471, North Terrace, Adelaide, SA, 5000, Australia.
| | - Mahin Moghaddami
- Centre for Pharmaceutical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, GPO Box 2471, North Terrace, Adelaide, SA, 5000, Australia
| | - Larisa Bobrovskaya
- Centre for Pharmaceutical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, GPO Box 2471, North Terrace, Adelaide, SA, 5000, Australia
| | - Susanna M Proudman
- Royal Adelaide Hospital and The University of Adelaide, Adelaide Medical School, Adelaide, SA, Australia
| | - Michael D Wiese
- Centre for Pharmaceutical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, GPO Box 2471, North Terrace, Adelaide, SA, 5000, Australia
| |
Collapse
|
17
|
Susan Mathew B, Mathew SK, Winston Aruldhas B, Prabha R, Gangadharan N, George David V, Varughese S, Tharayil John G. Analytical and clinical validation of Dried blood spot and Volumetric Absorptive Microsampling for measurement of tacrolimus and creatinine after renal transplantation. Clin Biochem 2022; 105-106:25-34. [PMID: 35490728 DOI: 10.1016/j.clinbiochem.2022.04.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 04/22/2022] [Accepted: 04/25/2022] [Indexed: 12/28/2022]
Abstract
BACKGROUND Serial monitoring of tacrolimus and serum creatinine after renal transplantation is of vital importance. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the estimation of tacrolimus and creatinine, obtained from dried blood spots (DBS) or by volumetric absorptive microsampling (VAMS) was validated and the two sampling strategies were compared with traditional venous sampling. METHODS The LC-MS/MS assay was validated using a shared extract for the estimation of tacrolimus and creatinine from DBS and VAMS independently. The relationship between the concentrations in DBS/VAMS specimens and in venous samples was assessed using Passing-Bablok (PB) analysis and the bias between the two methods was determined by the Bland Altman (BA) analysis. RESULTS The imprecision and bias of tacrolimus and creatinine estimated from DBS and VAMS samples was <12% and was independent of the hematocrit (Hct). Samples were stable for five days at ambient temperature. From the PB regression analysis, correction equations were generated for the prediction of tacrolimus and creatinine values from DBS and VAMS samples. In a separate cohort of patients for validation, the corrected DBS and VAMS concentrations had a mean (95% CI) bias for tacrolimus of -0.64 (-2.98 to 1.70)% and -0.92 (-3.69 to 1.85)% respectively and for creatinine of 1.00 (-2.73 to 4.72)% and -0.71 (-3.74 to 2.32)% respectively. Using DBS and VAMS respectively, for tacrolimus, 91.8 and 89.8% of patient values and for creatinine, 69.4 and 81.6% of patient values were within the limits of clinical acceptance (within 15% agreement against the venous samples). CONCLUSION We conclude that VAMS is the preferred single sampling option for estimating tacrolimus and creatinine in renal transplant patients.
Collapse
Affiliation(s)
- Binu Susan Mathew
- Department of Pharmacology and Clinical Pharmacology, Christian Medical College, Vellore, Tamil Nadu, India.
| | - Sumith K Mathew
- Department of Pharmacology and Clinical Pharmacology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Blessed Winston Aruldhas
- Department of Pharmacology and Clinical Pharmacology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Ratna Prabha
- Department of Pharmacology and Clinical Pharmacology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Naveen Gangadharan
- Department of Bioengineering, Christian Medical College, Vellore, Tamil Nadu, India
| | - Vinoi George David
- Department of Nephrology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Santosh Varughese
- Department of Nephrology, Christian Medical College, Vellore, Tamil Nadu, India
| | - George Tharayil John
- Department of Renal Medicine, Royal Brisbane and Women's Hospital, Brisbane, Australia
| |
Collapse
|
18
|
Koutsimpani-Wagner A, Quartucci C, Rooney JPK, Bose-O'Reilly S, Rakete S. Mercury biomonitoring in German adults using volumetric absorptive microsampling. Environ Monit Assess 2022; 194:315. [PMID: 35355133 PMCID: PMC8969040 DOI: 10.1007/s10661-022-09962-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/19/2022] [Indexed: 06/09/2023]
Abstract
Mercury (Hg) is a global pollutant and a danger to human health. Human biomonitoring of Hg using a dried blood matrix instead of venous blood sampling for exposure assessment is of growing interest. This study aims to develop, validate, and evaluate the application of volumetric absorptive microsampling (VAMS) for Hg biomonitoring in humans. Sampling, drying, and storage conditions were evaluated during method development. Storage in pre-cleaned glass vials after drying for 2 h in a desiccator ensured analyte stability for at least 4 weeks. Sixty-eight paired capillary VAMS and venous blood samples from volunteers in Munich, Germany, were used for method validation. Hg levels in VAMS and venous blood samples were determined by direct mercury analysis. The limits of detection and quantitation for VAMS were 0.18 and 0.61 µg/l, respectively. However, sensitivity could be improved by using two microsamples for analysis instead of one. Hg levels in VAMS samples correlated very well with Hg levels in venous blood samples (R2 = 0.958). Furthermore, VAMS showed a high accuracy (median recovery: 117%) and precision (median relative standard deviation: 8.7%), especially for Hg concentrations above 1.0 µg/l. In fact, accuracy and precision of VAMS improved with increasing Hg concentrations. In conclusion, VAMS in combination with direct mercury analysis is an accurate and viable alternative for human biomonitoring of Hg.
Collapse
Affiliation(s)
- Anastasia Koutsimpani-Wagner
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Ziemssenstraße 5, 80336, Munich, Germany
| | - Caroline Quartucci
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Ziemssenstraße 5, 80336, Munich, Germany
- Institute for Occupational Health and Product Safety, Bavarian Health and Food Safety Authority, Environmental Health, Munich, Germany
| | - James P K Rooney
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Ziemssenstraße 5, 80336, Munich, Germany
- Academic Unit of Neurology, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland
| | - Stephan Bose-O'Reilly
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Ziemssenstraße 5, 80336, Munich, Germany
- Department of Public HealthInstitute of Public Health, Medical Decision Making and Health Technology AssessmentMedical Informatics and Technology, Health Services Research and Health Technology Assessment, UMIT - Private University for Health Sciences, Hall i.T., Austria
| | - Stefan Rakete
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Ziemssenstraße 5, 80336, Munich, Germany.
| |
Collapse
|
19
|
Rajadhyaksha M, Londhe V. Microsampling: A role to play in Covid-19 diagnosis, surveillance, treatment and clinical trials. Drug Test Anal 2021; 13:1238-1248. [PMID: 34089576 DOI: 10.1002/dta.3107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/29/2021] [Accepted: 06/01/2021] [Indexed: 12/13/2022]
Abstract
The outbreak of the new coronavirus disease changed the world upside down. Every day, millions of people were subjected to diagnostic testing for Covid-19, all over the world. Molecular tests helped in the diagnosis of current infection by detecting the presence of viral genome whereas serological tests helped in detecting the presence of antibody in blood as well as contributed to vaccine development. This testing helped in understanding the immunogenicity, community prevalence, geographical spread and conditions post-infection. However, with the contagious nature of the virus, biological specimen sampling involved the risk of transmission and spread of infection. Clinic or pathology visit was the most concerning part. Trained personnel and resources was another barrier. In this scenario, microsampling played an important role due to its most important advantage of remote, contactless, small volume and self-sampling. Minimum requirements for sample storage and ease of shipment added value in this situation. The highly sensitive instruments and validated assay formats assured the accuracy of results and stability of samples. Microsampling techniques are contributing effectively to the Covid-19 pandemic by reducing the demand for clinical staff in population-level testing. The validated and established applications supported the use of microsampling in diagnosis, therapeutic drug monitoring, development of treatment or vaccines and clinical trials for Covid-19.
Collapse
Affiliation(s)
- Madhura Rajadhyaksha
- SPPSPTM, SVKM's Narsee Monjee Institute of Management Studies, Mumbai, India.,Sitec Labs. Ltd., Navi Mumbai, India
| | - Vaishali Londhe
- SPPSPTM, SVKM's Narsee Monjee Institute of Management Studies, Mumbai, India
| |
Collapse
|
20
|
Maggadani BP, Harmita, Haryono SJ, Rinaldi MR, Harahap Y. Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients. Drug Des Devel Ther 2021; 15:2417-2430. [PMID: 34113081 PMCID: PMC8187001 DOI: 10.2147/dddt.s286409] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 04/14/2021] [Indexed: 01/11/2023] Open
Abstract
INTRODUCTION In this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active metabolites. METHODS VAMS extraction was performed in methanol by sonication-assisted extraction method for 25 min after 2 hof VAMS drying. Separation was carried out using Acquity UPLC BEH C18 column (2.1 x 100 mm; 1.7 µm), with a flow rate of 0.2 mL/min, and the mobile phase gradient of formic acid 0.1% and formic acid 0.1% in acetonitrile for 5 min. The multiple reaction monitoring (MRM) values were set at m/z 358.31>58.27 for N-desmethyltamoxifen, m/z 372.33>72.28 for tamoxifen, m/z 388.22>72.28 for 4-hydroxytamoxifen, m/z 374.25>58.25 for endoxifen, and m/z 260.26>116.12 for propranolol. RESULTS AND DISCUSSION The lower limit of quantification value (LLOQ) was 2.50 ng/mL for tamoxifen, 2.50 ng/mL for endoxifen, 1.50 ng/mL for 4-hydroxitamoxifen, and 2.00 ng/mL for N-desmethyltamoxifen. Accuracy (%bias) and precision (%CV) were within 20% for LLOQ and 15% for other concentrations. There were no interference responses >20% of the LLOQ and 5% of the internal standard. The level of ion suppression in all analytes was less than 7%. The preparation system developed in this study successfully extracted more than 90% of analytes from the matrix with precision below 15%. Carryover was shown to be below 6% in all analytes. Stability of analytes in VAMS was demonstrated for up to 30 days, under room temperature storage in a sealed plastic bag with desiccant. This method was successfully applied to analyze tamoxifen and the metabolites level in 30 ER+ breast cancer patients.
Collapse
Affiliation(s)
| | - Harmita
- Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia
| | - Samuel J Haryono
- Surgical Oncology Division, MRCCC Siloam Hospital, Jakarta, Indonesia
| | | | - Yahdiana Harahap
- Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia
| |
Collapse
|
21
|
Maggadani BP, Harahap Y, Harmita, Haryono SJ, Untu CWP. Analysis of tamoxifen and its metabolites in dried blood spot and volumetric absorptive microsampling: comparison and clinical application. Heliyon 2021; 7:e07275. [PMID: 34179536 PMCID: PMC8213905 DOI: 10.1016/j.heliyon.2021.e07275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/22/2021] [Accepted: 06/07/2021] [Indexed: 10/29/2022] Open
Abstract
This research was conducted to develop the Dried Blood Spot (DBS) and Volumetric Absorptive Microsampling (VAMS) method in the analysis of Tamoxifen (TAM) and its metabolites endoxifen (END), 4-hydroxytamoxifen (4-HT), and N-desmethyltamoxifen (NDT) using Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS). This method was then applied to monitor TAM and its metabolites in breast cancer patients. The UPLC-MS/MS method was developed and validated with propranolol as the internal standard. The recovery and matrix effects on DBS and VAMS were investigated. The validation requirements were fulfilled by the methodology of analysis and sample preparation described in this study. Both VAMS and DBS extraction recoveries were satisfactory, with low variability. Extraction recovery in the VAMS sample was found to be slightly higher than in the DBS sample. Sample stability in DBS and VAMS was demonstrated for up to 2 months. Both of these methods were successfully applied for the analysis of TAM and metabolites in clinical patients. The mean concentrations obtained from the two methods were not significantly different.
Collapse
Affiliation(s)
| | - Yahdiana Harahap
- Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia
- Indonesia Defense University, Bogor 16810, West Java, Indonesia
| | - Harmita
- Faculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia
| | - Samuel J. Haryono
- Surgical Oncology Division, SJH Initiative-MRCCC Siloam Hospital, Jakarta, Indonesia
| | | |
Collapse
|
22
|
Al-Qurain AA, Williams DB, Mackenzie L, Roberts MS, Wiese MD. Simultaneous LC-MS/MS quantification of oxycodone, tramadol and fentanyl and their metabolites (noroxycodone, oxymorphone, O- desmethyltramadol, N- desmethyltramadol, and norfentanyl) in human plasma and whole blood collected via venepuncture and volumetric absorptive micro sampling. J Pharm Biomed Anal 2021; 203:114171. [PMID: 34087551 DOI: 10.1016/j.jpba.2021.114171] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 05/16/2021] [Accepted: 05/23/2021] [Indexed: 11/16/2022]
Abstract
INTRODUCTION A range of opioids are commonly prescribed to manage chronic pain, but individual patient responses vary greatly, especially in older populations. One source of that variability are differences in absorption, metabolism and excretion, i.e. pharmacokinetics. Blood, plasma and serum concentrations of opioids allow that variability to be quantified and may be used to optimise opioid dosing. As an aid to that process, there is an unmet need to rapidly quantify several opioids and their metabolites in a single analytical method. AIMS To develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of tramadol, oxycodone, fentanyl and their major metabolites in various human matrices. METHODS Sample preparation involved adding three deuterated internal standards followed by protein precipitation with 100 % acetonitrile, evaporation and reconstitution. Separation of analytes via LC was achieved on a reversed phase column via binary gradient elution using 0.005 % formic acid in water and 100 % acetonitrile as mobile phases. Analytes were detected via MS/MS with multiple reaction monitoring (MRM). RESULTS The method was accurate with the inter-day and intra-day accuracy of quality control samples (QCs) below 15 %. It was also precise with inter-day and intra-day coefficient of variation below 15 %. The lower limit of quantification (LLOQ) was 0.2 ng/mL for all analytes except tramadol and its metabolites, where the LLOQ was 10 ng/mL. Recovery was greater than 88 % for all analytes, except for O-desmethyltramadol (81 %). Analytes were stable over four freeze-thaw cycles, for 24 h on the bench top and for 24 h post-preparation. The inter- and intra-day variability of concentrations determined in blood and plasma were within 84-124%, whereas the inter- and intra-day variability for blood samples prepared using volumetric absorptive micro-sampling (VAMS) compared to those prepared from whole blood ranged between 83-122%. CONCLUSION A LC-MS/MS method is described that is able to accurately and precisely quantify a number of commonly prescribed opioids and their major metabolites in plasma and whole blood, including whole blood collected using VAMS.
Collapse
Affiliation(s)
- Aymen A Al-Qurain
- UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, Australia; Basil Hetzel Institute for Translational Medical Research, The Queen Elizabeth Hospital, Woodville, Australia; Saudi Arabian Cultural Mission, Ministry of Education, Riyadh, Saudi Arabia; Health and Biomedical Innovation, University of South Australia, Adelaide, Australia.
| | - Desmond B Williams
- UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, Australia
| | - Lorraine Mackenzie
- UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, Australia; Basil Hetzel Institute for Translational Medical Research, The Queen Elizabeth Hospital, Woodville, Australia
| | - Michael S Roberts
- UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, Australia; Basil Hetzel Institute for Translational Medical Research, The Queen Elizabeth Hospital, Woodville, Australia; Therapeutics Research Centre, Diamantina Institute, Translational Research Institute, The University of Queensland, Brisbane, Queensland, Australia
| | - Michael D Wiese
- UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, Australia; Health and Biomedical Innovation, University of South Australia, Adelaide, Australia
| |
Collapse
|
23
|
Vidal A, Belova L, Stove C, De Boevre M, De Saeger S. Volumetric Absorptive Microsampling as an Alternative Tool for Biomonitoring of Multi-Mycotoxin Exposure in Resource-Limited Areas. Toxins (Basel) 2021; 13:345. [PMID: 34064925 PMCID: PMC8150583 DOI: 10.3390/toxins13050345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 05/04/2021] [Accepted: 05/06/2021] [Indexed: 12/13/2022] Open
Abstract
Biomonitoring of biological samples arises as an effective tool to evaluate the exposure to mycotoxins in the population. Owing to the wide range of advantages, there is a growing interest in the use of non- and minimally invasive alternative sampling strategies, such as dried blood spot sampling or volumetric absorptive microsampling (VAMS). A VAMS-based multi-mycotoxin method was developed and validated for 24 different mycotoxins. Method validation was based on the Bioanalytical Method Validation Guideline of the Food and Drug Administration from the United States and for most of the studied mycotoxins, the results of the performance characteristics were in agreement with the criteria of the European Commission Decision 2002/657/EC. The recovery for the different mycotoxins was not haematocrit dependent and remained acceptable after storing the VAMS for 7 and 21 days at refrigeration temperature (4 °C) and room temperature, demonstrating that VAMS could be applied to assess mycotoxin exposure in blood in resource-limited areas, where there may be a delay between sampling and analysis. Finally, a comparison between VAMS and a procedure for liquid whole blood analysis, performed on 20 different blood samples, did not result in missed exposed cases for VAMS. Moreover, both methods detected similar levels of ochratoxin A, ochratoxin alpha, zearalenone and aflatoxin B1. Given all the benefits associated with VAMS and the developed method, VAMS sampling may serve as an alternative to conventional venous sampling to evaluate multiple mycotoxin exposure.
Collapse
Affiliation(s)
- Arnau Vidal
- Centre of Excellence in Mycotoxicology and Public Health, Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; (L.B.); (M.D.B.); (S.D.S.)
| | - Lidia Belova
- Centre of Excellence in Mycotoxicology and Public Health, Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; (L.B.); (M.D.B.); (S.D.S.)
| | - Christophe Stove
- Laboratory of Toxicology, Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium;
| | - Marthe De Boevre
- Centre of Excellence in Mycotoxicology and Public Health, Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; (L.B.); (M.D.B.); (S.D.S.)
| | - Sarah De Saeger
- Centre of Excellence in Mycotoxicology and Public Health, Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; (L.B.); (M.D.B.); (S.D.S.)
| |
Collapse
|
24
|
Li H, Myzithras M, Bolella E, Leonard A, Ahlberg J. Whole blood stability evaluation of monoclonal antibody therapeutics using volumetric absorptive microsampling. Bioanalysis 2021; 13:621-9. [PMID: 33829873 DOI: 10.4155/bio-2021-0025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Volumetric absorptive microsampling (VAMS) is increasingly utilized for both nonclinical and clinical pharmacokinetic studies. Currently, VAMS is employed as the sampling method for the detection of antibodies for coronavirus disease 2019. Biotherapeutics whole blood stability on VAMS presents as a critical concern for the health and pharmaceutical industries. In this follow-up to our previous publication, we evaluated daclizumab and trastuzumab whole blood sample stability on VAMS. The drug recovery data we observed at room temperature for short term and -80°C for long term was very encouraging. The knowledge could help us better understand and plan important investigation timelines, especially pandemic situations where human whole blood samples from a large population are collected and in urgent need of data analysis.
Collapse
|
25
|
Mingas PD, Zdovc J, Grabnar I, Vovk T. The Evolving Role of Microsampling in Therapeutic Drug Monitoring of Monoclonal Antibodies in Inflammatory Diseases. Molecules 2021; 26:1787. [PMID: 33810104 DOI: 10.3390/molecules26061787] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/18/2021] [Accepted: 03/19/2021] [Indexed: 12/17/2022] Open
Abstract
Monoclonal antibodies (mAbs) have been extensively developed over the past few years, for the treatment of various inflammatory diseases. They are large molecules characterized by complex pharmacokinetic and pharmacodynamic properties. Therapeutic drug monitoring (TDM) is routinely implemented in the therapy with mAbs, to monitor patients’ treatment response and to further guide dose adjustments. Serum has been the matrix of choice in the TDM of mAbs and its sampling requires the visit of the patients to laboratories that are not always easily accessible. Therefore, dried blood spots (DBS) and various microsampling techniques have been suggested as an alternative. DBS is a sampling technique in which capillary blood is deposited on a special filter paper. It is a relatively simple procedure, and the patients can perform the home-sampling. The convenience it offers has enabled its use in the quantification of small-molecule drugs, whilst in the recent years, studies aimed to develop microsampling methods that will facilitate the TDM of mAbs. Nevertheless, hematocrit still remains an obstacle that hinders a more widespread implementation of DBS in clinical practice. The introduction of novel analytical techniques and contemporary microsampling devices can be considered the steppingstone to the attempts made addressing this issue.
Collapse
|
26
|
Jacobs CM, Wagmann L, Meyer MR. Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics. Anal Bioanal Chem 2021; 413:1729-37. [PMID: 33517479 DOI: 10.1007/s00216-020-03143-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 12/16/2020] [Accepted: 12/22/2020] [Indexed: 12/27/2022]
Abstract
Volumetric absorptive microsampling (VAMS), an emerging microsampling technique, is expected to overcome some disadvantages of dried blood spots such as volume inaccuracy and influence of hematocrit (HT). This study aimed to develop and evaluate a VAMS-based strategy for quantification of 13 frequently prescribed antipsychotics in finger prick blood within the scope of adherence monitoring to complement already-established qualitative urine analysis. The final workflow consisted of VAMS tip hydration and subsequent precipitation. Samples were analyzed by using reversed-phase ultra-high-performance liquid chromatography and Orbitrap mass spectrometry operated in parallel reaction monitoring mode. The analytical procedure was successfully validated based on international recommendations at three different HT values (20%, 40%, 60%) for most of the analytes. Selectivity and within/between-run accuracy and precision were in accordance with the recommendations in most cases. Internal standard–normalized matrix factor met recommended criteria for all analytes at HT 40%. For the HT values of 20% and 60%, only four substances did not meet the criteria. Dilution integrity was given for all substances, except for olanzapine, allowing a quantification over the whole therapeutic range of selected antipsychotics. Long-term stability in VAMS tips was tested and revealed degradation of five antipsychotic drugs after 1 week of storage at 24 °C. A proof of concept of the applicability of the method was obtained by quantification of a selection of the 13 antipsychotic drugs in VAMS tips and matched plasma samples. Results were coherent between matrices. Thus, VAMS was shown to be a promising alternative for adherence monitoring of at least the investigated antipsychotics.
Collapse
|
27
|
Gao X, Chen C, Geng D, Bateman KP, Shi S, Woolf EJ, Xu Y. Volumetric absorptive microsampling ( VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development. J Pharm Biomed Anal 2021; 196:113895. [PMID: 33486450 DOI: 10.1016/j.jpba.2021.113895] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 12/02/2020] [Accepted: 01/05/2021] [Indexed: 01/01/2023]
Abstract
Microsampling techniques have been employed as an alternative to traditional serum/plasma sampling because of their inherently proven and desirable advantages across the pharmaceutical industry. These include reduced animal usage in pre-clinical studies, as well as, permitting the collection of samples that would otherwise be inaccessible in clinical studies. The application of volumetric absorptive microsampling (VAMS®) technology, a second-generation dried microsampling method, coupled with LC-MS, has been extensively explored for small molecule drugs at various drug development stages. However, the potential of using VAMS technology and LC-MS analysis for biological therapeutic development has yet to be well-established. In this work, we describe the method development, validation, and a proof-of-concept non-human primate study of a LC-MS/MS method for VAMS utilized to obtain pharmacokinetic (PK) data for a therapeutic monoclonal antibody. A good correlation between VAMS data and data from conventional serum samples was established in rhesus monkeys and indicated the possibility of using of this novel sampling technology in clinical studies. However, during the initial clinical study, a significant difference in internal standard (IS) response between the patient fingerstick samples and the standard/QC samples was observed, which posed a question on the accuracy of the clinical results. A comprehensive investigation confirmed that the EDTA anticoagulant used in the standard/QC samples was the root cause of the observed anomalous IS responses. Special considerations and corresponding best practices during method development and validation are proposed to ensure early detection of potential issues and appropriate implementation of VAMS technology in clinical studies in the future.
Collapse
Affiliation(s)
- Xinliu Gao
- Analytical Research & Development Mass Spectrometry, Merck & Co., Inc., 2000 Galloping Hill Road Kenilworth, NJ, 07033, USA.
| | - Cindy Chen
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA
| | - Dong Geng
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA
| | - Kevin P Bateman
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA
| | - Shuangping Shi
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA
| | - Eric J Woolf
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA
| | - Yang Xu
- Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Merck & Co., Inc, 770 Sumneytown Pike, WP75B-300, West Point, PA, 19486, USA.
| |
Collapse
|
28
|
Marasca C, Arana MEB, Protti M, Cavalli A, Mercolini L, Armirotti A. Volumetric Absorptive Microsampling of Blood for Untargeted Lipidomics. Molecules 2021; 26:E262. [PMID: 33430231 DOI: 10.3390/molecules26020262] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 12/28/2020] [Accepted: 01/04/2021] [Indexed: 01/20/2023] Open
Abstract
In the present, proof-of-concept paper, we explore the potential of one common solid support for blood microsampling (dried blood spot, DBS) and a device (volumetric absorptive microsampling, VAMS) developed for the untargeted lipidomic profiling of human whole blood, performed by high-resolution LC-MS/MS. Dried blood microsamples obtained by means of DBS and VAMS were extracted with different solvent compositions and compared with fluid blood to evaluate their efficiency in profiling the lipid chemical space in the most broad way. Although more effort is needed to better characterize this approach, our results indicate that VAMS is a viable option for untargeted studies and its use will bring all the corresponding known advantages in the field of lipidomics, such as haematocrit independence.
Collapse
|
29
|
Harahap Y, Diptasaadya R, Purwanto DJ. Volumetric Absorptive Microsampling as a Sampling Alternative in Clinical Trials and Therapeutic Drug Monitoring During the COVID-19 Pandemic: A Review. Drug Des Devel Ther 2020; 14:5757-5771. [PMID: 33414636 PMCID: PMC7783192 DOI: 10.2147/dddt.s278892] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 11/17/2020] [Indexed: 12/12/2022]
Abstract
An infectious disease, COVID-19, caused by a new type of coronavirus, has been discovered recently. This disease can cause respiratory distress, fever, and fatigue. It still has no drug and vaccine for treatment and prevention. Therefore, WHO recommends that people should stay at home to reduce disease transmission. Due to the quarantine, FDA stated that this could hamper drug development clinical trial protocols. Hence, an alternative sampling method that can be applied at home is needed. Currently, volumetric absorptive microsampling (VAMS) has become attention in its use in clinical and bioanalytical fields. This paper discusses the advantages and challenges that might be found in the use of VAMS as an alternative sampling tool in clinical trials and therapeutic drug monitoring (TDM) during the COVID-19 pandemic. VAMS allows easy sampling, can be done at home, storage and delivery at room temperature, and the volume taken is small and minimally invasive. VAMS is also able to absorb a fixed volume that can increase the accuracy and precision of analytical methods, and reduce the hematocrit effects (HCT). The use of VAMS is expected to be implemented immediately in clinical trials and TDM during this pandemic considering the benefits it has.
Collapse
Affiliation(s)
- Yahdiana Harahap
- Faculty of Pharmacy, Universitas Indonesia, Depok, West Java 16424, Indonesia
| | - Rasmina Diptasaadya
- Faculty of Pharmacy, Universitas Indonesia, Depok, West Java 16424, Indonesia
| | - Denni Joko Purwanto
- Functional Medical Staff of Surgical Oncology, Dharmais Cancer Hospital, Jakarta 11420, Indonesia
| |
Collapse
|
30
|
Protti M, Mandrioli R, Mercolini L. Quantitative microsampling for bioanalytical applications related to the SARS-CoV-2 pandemic: Usefulness, benefits and pitfalls. J Pharm Biomed Anal 2020; 191:113597. [PMID: 32927419 PMCID: PMC7456588 DOI: 10.1016/j.jpba.2020.113597] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/23/2020] [Accepted: 08/25/2020] [Indexed: 12/20/2022]
Abstract
SARS-CoV-2 emergency sparks the need for diagnostic and therapeutic actions. Microsampling is emerging in as an attractive alternative to traditional sampling. Advantages and challenges of the main microsampling techniques are reported. Available microsampling applications of interest for SARS-CoV-2 are described. Most useful information for researchers and clinicians are gathered and provided.
The multiple pathological effects of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, and its total novelty, mean that currently a lot of diagnostic and therapeutic tools, established and tentative alike, are needed to treat patients in a timely, effective way. In order to make these tools more reliable, faster and more feasible, biological fluid microsampling techniques could provide many advantages. In this review, the most important microsampling techniques are considered (dried matrix spots, volumetric absorptive microsampling, microfluidics and capillary microsampling, solid phase microextraction) and their respective advantages and disadvantages laid out. Moreover, currently available microsampling applications of interest for SARS-CoV-2 therapy are described, in order to make them as much widely known as possible, hopefully providing useful information to researchers and clinicians alike.
Collapse
Affiliation(s)
- Michele Protti
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy
| | - Roberto Mandrioli
- Department for Life Quality Studies, Alma Mater Studiorum - University of Bologna, Corso d'Augusto 237, 47921 Rimini, Italy
| | - Laura Mercolini
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.
| |
Collapse
|
31
|
Roadcap B, Hussain A, Dreyer D, Carter K, Dube N, Xu Y, Anderson M, Berthier E, Vazvaei F, Bateman K, Woolf E. Clinical application of volumetric absorptive microsampling to the gefapixant development program. Bioanalysis 2020; 12:893-904. [PMID: 32648772 DOI: 10.4155/bio-2020-0074] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
In this paper we show the application of the Tasso OnDemand™, a novel automated sample collection device, in conjunction with volumetric absorptive microsampling (VAMS) for the development of gefapixant, a P2X3 receptor antagonist currently under clinical development for the treatment of refractory and unexplained chronic cough and endometriosis-related pain. A LC-MS/MS bioanalytical method was developed and validated using VAMS to support this development program. This method was utilized in a drug-drug interaction study to establish a mathematical bridging relationship with data obtained from a validated plasma assay used to support the program. The VAMS bioanalytical method and the predictability of the mathematical relationship is reported and discussed here.
Collapse
|
32
|
Leaney AE, Horner C, Grace PB, Mawson DH. Selection of a surrogate matrix for the quantification of an endogenous analyte in dried whole blood. Bioanalysis 2020; 12:409-18. [PMID: 32209027 DOI: 10.4155/bio-2020-0012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Aim: A surrogate matrix is needed to quantify 25-hydroxyvitamin D3 in dried whole blood (DWB). To date, there has been limited guidance on approaches for quantification of endogenous analytes in atypical matrices, such as DWB. Methods: Different surrogate matrices were investigated in a systematic process using an LC-MS/MS assay. Performance assessment was made using quality controls of DWB with different hematocrits. Results & conclusion: Suitability of both phosphate-buffered saline containing bovine serum albumin and washed red blood cells recombined with phosphate-buffered saline containing bovine serum albumin as a surrogate matrix was demonstrated across a range of concentrations and hematocrits representative of expected endogenous analyte samples.
Collapse
|
33
|
Mandrioli R, Mercolini L, Protti M. Blood and Plasma Volumetric Absorptive Microsampling ( VAMS) Coupled to LC-MS/MS for the Forensic Assessment of Cocaine Consumption. Molecules 2020; 25:E1046. [PMID: 32110941 DOI: 10.3390/molecules25051046] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/01/2023] Open
Abstract
Reliable, feasible analytical methods are needed for forensic and anti-doping testing of cocaine and its most important metabolites, benzoylecgonine, ecgonine methyl ester, and cocaethylene (the active metabolite formed in the presence of ethanol). An innovative workflow is presented here, using minute amounts of dried blood or plasma obtained by volumetric absorptive microsampling (VAMS), followed by miniaturized pretreatment by dispersive pipette extraction (DPX) and LC-MS/MS analysis. After sampling 20 µL of blood or plasma with a VAMS device, the sample was dried, extracted, and loaded onto a DPX tip. The DPX pretreatment lasted less than one minute and after elution with methanol the sample was directly injected into the LC-MS/MS system. The chromatographic analysis was carried out on a C8 column, using a mobile phase containing aqueous formic acid and acetonitrile. Good extraction yield (> 85%), precision (relative standard deviation, RSD < 6.0%) and matrix effect (< 12%) values were obtained. Analyte stability was outstanding (recovery > 85% after 2 months at room temperature). The method was successfully applied to real blood and plasma VAMS, with results in very good agreement with those of fluid samples. The method seems suitable for the monitoring of concomitant cocaine and ethanol use by means of plasma or blood VAMS testing.
Collapse
|
34
|
Ion V, Legoff C, Cavalier E, Delanaye P, Servais AC, Muntean DL, Fillet M. Determination of iohexol by capillary blood microsampling and UHPLC-MS/MS. J Pharm Anal 2019; 9:259-265. [PMID: 31452964 PMCID: PMC6702420 DOI: 10.1016/j.jpha.2019.06.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 06/25/2019] [Accepted: 06/26/2019] [Indexed: 12/13/2022] Open
Abstract
One of the most important tools used to evaluate kidney function in the context of chronic kidney disease or other renal function related pathologies is the exploration of glomerular filtration rate (GFR). Iohexol is up to this moment a good candidate molecule for the GFR assessment since it exhibits minimum protein binding rates and minimum extra-renal clearance, being neither secreted nor reabsorbed at the tubular level. This study proposes and evaluates a new LC-MS/MS method for the iohexol determination from capillary blood, prelevated using volumetric absorbative microsampling (VAMS) systems. As an alternative to VAMS, a brand new HemaPEN® device for micro-prelevation was also tested. A new high throughput sample preparation protocol adapted for iohexol quantification from whole blood VAMS samples was developed. The medium term stability study of iohexol in dried whole blood VAMS samples that was conducted showed a good stability of this molecule for up to 12 days. By collecting only 10 μL of blood, iohexol can be analyzed from dried whole blood VAMS samples for concentration ranges between 1 and 250 μg/mL. Due to the analyte stability in VAMS for up to 12 days, this approach might be successfully applied for GFR assessment for clinical cases allowing minimum invasiveness and even delayed analysis. Successful VAMS-based bioanalytical method for iohexol analysis in whole human blood. Proven medium term stability of iohexol in VAMS samples. HemaPens as a promising alternative for iohexol analysis using only 2.74 μL of blood.
Collapse
Affiliation(s)
- Valentin Ion
- Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium.,Analytical Chemistry and Drug Analysis Department, Faculty of Pharmacy, University of Medicine Pharmacy Science and Technology from Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
| | - Caroline Legoff
- Department of Clinical Chemistry, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, CHU Sart-Tilman, Liège, Belgium
| | - Etienne Cavalier
- Department of Clinical Chemistry, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, CHU Sart-Tilman, Liège, Belgium
| | - Pierre Delanaye
- Department of Nephrology-Dialysis-Transplantation, University of Liège, CHU Sart-Tilman, Liege, Belgium
| | - Anne-Catherine Servais
- Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium
| | - Daniela-Lucia Muntean
- Analytical Chemistry and Drug Analysis Department, Faculty of Pharmacy, University of Medicine Pharmacy Science and Technology from Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
| | - Marianne Fillet
- Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium
| |
Collapse
|
35
|
Volani C, Paglia G, Smarason SV, Pramstaller PP, Demetz E, Pfeifhofer-Obermair C, Weiss G. Metabolic Signature of Dietary Iron Overload in a Mouse Model. Cells 2018; 7:cells7120264. [PMID: 30544931 PMCID: PMC6315421 DOI: 10.3390/cells7120264] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 12/03/2018] [Accepted: 12/07/2018] [Indexed: 12/28/2022] Open
Abstract
Iron is an essential co-factor for several metabolic processes, including the Krebs cycle and mitochondrial oxidative phosphorylation. Therefore, maintaining an appropriate iron balance is essential to ensure sufficient energy production and to avoid excessive reactive oxygen species formation. Iron overload impairs mitochondrial fitness; however, little is known about the associated metabolic changes. Here we aimed to characterize the metabolic signature triggered by dietary iron overload over time in a mouse model, where mice received either a standard or a high-iron diet. Metabolic profiling was assessed in blood, plasma and liver tissue. Peripheral blood was collected by means of volumetric absorptive microsampling (VAMS). Extracted blood and tissue metabolites were analyzed by liquid chromatography combined to high resolution mass spectrometry. Upon dietary iron loading we found increased glucose, aspartic acid and 2-/3-hydroxybutyric acid levels but low lactate and malate levels in peripheral blood and plasma, pointing to a re-programming of glucose homeostasis and the Krebs cycle. Further, iron loading resulted in the stimulation of the urea cycle in the liver. In addition, oxidative stress was enhanced in circulation and coincided with increased liver glutathione and systemic cysteine synthesis. Overall, iron supplementation affected several central metabolic circuits over time. Hence, in vivo investigation of metabolic signatures represents a novel and useful tool for getting deeper insights into iron-dependent regulatory circuits and for monitoring of patients with primary and secondary iron overload, and those ones receiving iron supplementation therapy.
Collapse
Affiliation(s)
- Chiara Volani
- Department of Internal Medicine II, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
- Christian Doppler Laboratory for Iron Metabolism and Anemia Research, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
- Institute for Biomedicine, Eurac Research, Via Galvani 31, 39100 Bolzano, Italy.
| | - Giuseppe Paglia
- Institute for Biomedicine, Eurac Research, Via Galvani 31, 39100 Bolzano, Italy.
| | - Sigurdur V Smarason
- Institute for Biomedicine, Eurac Research, Via Galvani 31, 39100 Bolzano, Italy.
| | - Peter P Pramstaller
- Institute for Biomedicine, Eurac Research, Via Galvani 31, 39100 Bolzano, Italy.
| | - Egon Demetz
- Department of Internal Medicine II, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
| | - Christa Pfeifhofer-Obermair
- Department of Internal Medicine II, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
| | - Guenter Weiss
- Department of Internal Medicine II, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
- Christian Doppler Laboratory for Iron Metabolism and Anemia Research, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.
| |
Collapse
|
36
|
Lundgren T, Reinebo G, Löf PO, Näslund M, Svartvadet P, Parling T. The Values, Acceptance, and Mindfulness Scale for Ice Hockey: A Psychometric Evaluation. Front Psychol 2018; 9:1794. [PMID: 30327624 PMCID: PMC6174276 DOI: 10.3389/fpsyg.2018.01794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 09/04/2018] [Indexed: 01/07/2023] Open
Abstract
There is an increased interest in mindfulness, acceptance, and values based skills training interventions in sports but there is a lack of psychometrically evaluated instruments to investigate the processes adapted to sport populations. This paper describes the development and investigation of an instrument that measure acceptance, mindfulness, and values for ice hockey players. Ice hockey players at elite and sub elite level (n = 94) in Sweden participated in the study. The results reveal that the values, acceptance, and mindfulness (VAMS) shows acceptable internal consistency (α = 0.76) and satisfactory validity. Furthermore, scores on the VAMS predicts ice hockey performance as measured by assists and team points. Future research is suggested to evaluate the sensitivity of the instrument for longitudinal research design studies. In conclusion, VAMS is a useful instrument for practitioners and researchers to increase the knowledge in how psychological processes such as acceptance, mindfulness, and values influence performance among ice hockey players.
Collapse
Affiliation(s)
- Tobias Lundgren
- Centre for Psychiatry Research, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden
- Stockholm Health Care Services, Stockholm County Council, Stockholm, Sweden
- Department of Psychology, Stockholm University, Stockholm, Sweden
| | - Gustaf Reinebo
- Centre for Psychiatry Research, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden
- Stockholm Health Care Services, Stockholm County Council, Stockholm, Sweden
| | - Per-Olov Löf
- Department of Psychology, Stockholm University, Stockholm, Sweden
| | | | | | - Thomas Parling
- Centre for Psychiatry Research, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden
- Stockholm Health Care Services, Stockholm County Council, Stockholm, Sweden
| |
Collapse
|
37
|
Protti M, Mandrioli R, Mercolini L. Tutorial: Volumetric absorptive microsampling ( VAMS). Anal Chim Acta 2018; 1046:32-47. [PMID: 30482302 DOI: 10.1016/j.aca.2018.09.004] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Revised: 08/31/2018] [Accepted: 09/03/2018] [Indexed: 01/21/2023]
Abstract
Volumetric absorptive microsampling (VAMS) is a recent microsampling technique used to obtain dried specimens of blood and other biological matrices for application to a plethora of bioanalytical purposes. As such, it can be likened to dried blood spot (DBS) technique that has been in wide use for the last 40 years. However, VAMS promises to bring some significant advantages over DBS, related to sampling volume accuracy, haematocrit (HCT) dependence, pre-treatment and automation. Although some aspects still need to be investigated in depth, VAMS is increasingly recognised as a viable alternative to DBS and other dried microsampling techniques. In this tutorial, different aspects of VAMS approach are described and discussed, presenting the procedures adopted and the results obtained by those authors who have developed this kind of analytical workflow in the last few years. Hopefully, this will help other scientists to find new solutions to old and recent problems related to microsampling and to produce new, sound and interesting science in this field.
Collapse
Affiliation(s)
- Michele Protti
- Pharmaco-Toxicological Analysis Laboratory (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Roberto Mandrioli
- Department for Life Quality Studies, Alma Mater Studiorum - University of Bologna, Rimini, Italy
| | - Laura Mercolini
- Pharmaco-Toxicological Analysis Laboratory (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Bologna, Italy.
| |
Collapse
|