1
|
Sohrabi Y, Rahimian F, Yousefinejad S, Aliasghari F, Soleimani E. Microextraction techniques for occupational biological monitoring: Basic principles, current applications and future perspectives. Biomed Chromatogr 2024; 38:e5883. [PMID: 38712625 DOI: 10.1002/bmc.5883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 03/01/2024] [Accepted: 04/01/2024] [Indexed: 05/08/2024]
Abstract
The application of green microextraction techniques (METs) is constantly being developed in different areas including pharmaceutical, forensic, food and environmental analysis. However, they are less used in biological monitoring of workers in occupational settings. Developing valid extraction methods and analytical techniques for the determination of occupational indicators plays a critical role in the management of workers' exposure to chemicals in workplaces. Microextraction techniques have become increasingly important because they are inexpensive, robust and environmentally friendly. This study aimed to provide a comprehensive review and interpret the applications of METs and novel sorbents and liquids in biological monitoring. Future perspectives and occupational indicators that METs have not yet been developed for are also discussed.
Collapse
Affiliation(s)
- Younes Sohrabi
- Department of Occupational Health and Safety Engineering, Shoushtar Faculty of Medical Sciences, Shoushtar, Iran
| | - Fatemeh Rahimian
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Yousefinejad
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Fereshteh Aliasghari
- Department of Clinical Nutrition, School of Nutrition and Food Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Esmaeel Soleimani
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
2
|
Dehghani F, Yousefinejad S, Mobaraki N, Nekoeinia M, Hemmateenejad B. Rapid determination of hippuric acid as an exposure biomarker of toluene using a colorimetric assay and comparison with high-performance liquid chromatography. Sci Rep 2024; 14:9935. [PMID: 38688900 PMCID: PMC11061108 DOI: 10.1038/s41598-024-59641-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 04/12/2024] [Indexed: 05/02/2024] Open
Abstract
Occupational exposure to toluene is associated with health risks that require reliable monitoring methods. Hippuric acid (HA), a urinary metabolite of toluene, serves as a valuable biomarker for such exposure. Colorimetric methods for the quantitative determination of HA have gained prominence due to their simplicity, cost-effectiveness, and suitability for field application. In the present study, a simple colorimetric technique was optimized for the determination of HA in the urine sample, and compared with a usual HPLC technique. The central composite design (CCD) was applied to examine the effective parameters on the colorimetric determination of HA. The calibration curve for HA was established within the concentration range of 6 to 100 mg L-1 with R2 = 0.97. The detection limit (LOD) and quantification limit (LOQ) were determined to be 1.8 mg L-1 and 6 mg L-1 respectively. The relative standard deviation (RSD%) was less than 5%, and the recovery% (R%) was 90.5-100.1. The overall results showed good agreement between the colorimetric and HPLC results. There was a significant relationship between the results obtained from HPLC and colorimetric methods especially for higher concentration levels of HA (≥ 500 mg/g creatinine). In conclusion, our optimized colorimetric method is a simple, cost-effective, and rapid method for determination of HA in occupational exposure, which is comparable with the HPLC technique.
Collapse
Affiliation(s)
- Fatemeh Dehghani
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Yousefinejad
- Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Nabiollah Mobaraki
- Institute of Medicinal and Pharmaceutical Chemistry, University of Technology Braunschweig, Braunschweig, Germany
| | - Mohsen Nekoeinia
- Soil and Water Research Department, Isfahan Agricultural and Natural Resources Research and Education Center, AREEO, Isfahan, Iran
| | | |
Collapse
|
3
|
Bolat S, Demir S, Erer H, Pelit F, Dzingelevičienė R, Ligor T, Buszewski B, Pelit L. MOF-801 based solid phase microextraction fiber for the monitoring of indoor BTEX pollution. JOURNAL OF HAZARDOUS MATERIALS 2024; 466:133607. [PMID: 38280318 DOI: 10.1016/j.jhazmat.2024.133607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 01/18/2024] [Accepted: 01/21/2024] [Indexed: 01/29/2024]
Abstract
Benzene, toluene, ethylbenzene and xylenes (BTEX) are some of the better-known indoor air pollutants, for which effective monitoring is important. The analysis of BTEX can be performed by different type of solid phase microextraction (SPME) fibers. This study presents a proposal for a low cost, convenient and environmentally friendly analytical method for the determination of BTEX in air samples using custom made SPME fibers. In this context, custom made metal organic frameworks (MOF-801) were coated on a stainless-steel wire for SPME fiber preparation. The analysis of BTEX was performed by introducing SPME fiber into an analyte-containing Tedlar bag in steady-state conditions. After the sampling step, the analytes were analyzed using gas chromatography mass spectrometry in selected ion monitoring mode. Parameters that affect the analysis results were optimized; these include desorption temperature and time, preconditioning time, extraction temperature and time, and sample volume. Under optimized conditions, analytical figure of merits of developed method were obtained, including limits of detection (LOD) (0.012 - 0.048 mg/m3), linear ranges (0.041-18 mg/m3), intraday and interday repeatability (2.08 - 4.04% and 3.94 - 6.35%), and fiber to fiber reproducibility (7.51 - 11.17%). The proposed method was successfully applied to real air samples with an acceptable recovery values between 84.5% and 110.9%. The developed method can be applied for the effective monitoring of BTEX.
Collapse
Affiliation(s)
- Serkan Bolat
- Department of Occupational Health and Safety, Vocational School, İzmir University of Economics, İzmir, Türkiye; Department of Chemistry, Faculty of Science, Ege University, İzmir, Türkiye.
| | - Sevde Demir
- Department of Chemistry, Faculty of Science, Eskişehir Osmangazi University, Eskişehir, Türkiye
| | - Hakan Erer
- Department of Chemistry, Faculty of Science, Eskişehir Osmangazi University, Eskişehir, Türkiye
| | - Füsun Pelit
- Department of Chemistry, Faculty of Science, Ege University, İzmir, Türkiye; Translational Pulmonary Research Center (Ege TPRC), Ege University, İzmir, Türkiye
| | - Reda Dzingelevičienė
- Faculty of Health Sciences, Marine Research Institute, Klaipeda University, Klaipeda, Lithuania
| | - Tomasz Ligor
- Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Toruń, Poland
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Toruń, Poland; Prof. Jan Czochralski Kuyavian-Pomeranian Science and Technology Center, 4 Krasińskiego str., 87 100 Toruń, Poland
| | - Levent Pelit
- Department of Chemistry, Faculty of Science, Ege University, İzmir, Türkiye; Translational Pulmonary Research Center (Ege TPRC), Ege University, İzmir, Türkiye
| |
Collapse
|
4
|
Chen J, Wang Y, Yu Y, Wang J, Liu J, Ihara H, Qiu H. Composite materials based on covalent organic frameworks for multiple advanced applications. EXPLORATION (BEIJING, CHINA) 2023; 3:20220144. [PMID: 37933382 PMCID: PMC10624394 DOI: 10.1002/exp.20220144] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Accepted: 03/10/2023] [Indexed: 11/08/2023]
Abstract
Covalent organic frameworks (COFs) stand for a class of emerging crystalline porous organic materials, which are ingeniously constructed with organic units through strong covalent bonds. Their excellent design capabilities, and uniform and tunable pore structure make them potential materials for various applications. With the continuous development of synthesis technique and nanoscience, COFs have been successfully combined with a variety of functional materials to form COFs-based composites with superior performance than individual components. This paper offers an overview of the development of different types of COFs-based composites reported so far, with particular focus on the applications of COFs-based composites. Moreover, the challenges and future development prospects of COFs-based composites are presented. We anticipate that the review will provide some inspiration for the further development of COFs-based composites.
Collapse
Affiliation(s)
- Jia Chen
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical PhysicsChinese Academy of SciencesLanzhouChina
| | - Yuting Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of SciencesNortheastern UniversityShenyangChina
| | - Yongliang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of SciencesNortheastern UniversityShenyangChina
| | - Jianhua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of SciencesNortheastern UniversityShenyangChina
| | - Juewen Liu
- Department of Chemistry, Waterloo Institute for NanotechnologyUniversity of WaterlooWaterlooOntarioCanada
| | - Hirotaka Ihara
- Department of Applied Chemistry and BiochemistryKumamoto UniversityChuo‐kuKumamotoJapan
| | - Hongdeng Qiu
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical PhysicsChinese Academy of SciencesLanzhouChina
| |
Collapse
|
5
|
Wang H, Han J, Li Z, Wang Z. Effective extraction of the metabolites of toluene and xylene based on a postsynthetic-modified magnetic covalent organic polymer. JOURNAL OF HAZARDOUS MATERIALS 2023; 447:130797. [PMID: 36680895 DOI: 10.1016/j.jhazmat.2023.130797] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/07/2023] [Accepted: 01/13/2023] [Indexed: 06/17/2023]
Abstract
Toluene and xylene are volatile organic compounds, and long-term exposure to toluene and xylene may cause brain structure and nervous system damage. To evaluate exposure to toluene and xylene in the environment, it is usually possible to monitor their metabolites in organisms, hippuric acid (HA) and methylhippuric acid (MHA). In this work, we designed a new magnetic solid phase extraction (MSPE) sorbent, zirconium postsynthetic-modified magnetic covalent organic polymer (Fe3O4@COP-COOZr), for purifying and enriching HA and 4-MHA. Zirconium ions were immobilized on the magnetic COP surface by postsynthetic modification without the use of additional coating layers or chelating ligands. The developed Fe3O4@COP-COOZr interacted with HA and 4-MHA through the π-π stacking effect and electrostatic interactions, as well as strong chelation with coordinatively unsaturated zirconium sites. The promising affinity material of Fe3O4@COP-COOZr in MSPE had high stability and recyclability. The established MSPE-HPLC-UV method showed low sorbent consumption (10 mg) and high sensitivity (LODs less than 0.1 μg L-1), and can be used for the analysis of HA and 4-MHA in real samples. The recoveries of the proposed method in real urine samples for the simultaneous determination of HA and 4-MHA were in the range of 83.5-103.2 %, and the RSDs were 0.9-7.1 %.
Collapse
Affiliation(s)
- Huiqi Wang
- Instrumental Analysis Center of Qingdao University, College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Qingdao University, Shandong 266071, China
| | - Jingjing Han
- Instrumental Analysis Center of Qingdao University, College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Qingdao University, Shandong 266071, China
| | - Zhanfeng Li
- Instrumental Analysis Center of Qingdao University, College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Qingdao University, Shandong 266071, China
| | - Zonghua Wang
- Instrumental Analysis Center of Qingdao University, College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Qingdao University, Shandong 266071, China.
| |
Collapse
|
6
|
Rahimian F, Soleimani E. A Review of Extraction Methods and Analytical Techniques for Styrene and its Metabolites in Biological Matrices. Biomed Chromatogr 2022; 36:e5440. [PMID: 35778991 DOI: 10.1002/bmc.5440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 06/28/2022] [Accepted: 06/29/2022] [Indexed: 11/12/2022]
Abstract
We reviewed the toxicokinetics of styrene to introduce reliable surrogates for biological monitoring of styrene workers. Also, extraction techniques and analytical methods for styrene and its metabolites have been discussed. Sample preparation is the main bottleneck of the analytical techniques for styrene and its metabolites. While some microextraction methods have been developed to overcome such drawbacks, some still have limitations such as long extraction time, fiber swelling and breakage, and the cost and the limited lifetime of the fiber. Among all, microextraction by packed sorbents coupled with high performance liquid chromatography with ultraviolet detection (MEPS-HPLC-UV) can be the method of choice for determining styrene metabolites. Few studies investigated unchanged styrene in breath samples. Chemical determination in exhaled breath provides new insights into organ toxicity in workers with inhalation exposures and can be considered as a fascinating tool in risk assessment strategies. Taking blood samples is invasive and less accepted by workers than other samples. In contrast, breath analysis is the most attractive method for workers because breath samples are easy to collect and non-invasive, and does not require worker transfer to health facilities. Therefore, developing selective and sensitive methods for determining styrene in breath samples is recommended for future studies.
Collapse
Affiliation(s)
- Fatemeh Rahimian
- Department of Occupational Health, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Esmaeel Soleimani
- Department of Occupational Health, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|