1
|
Ahmad D, Sá MP, Makani A, Kliner D, Toma C, Christensen E, Wang Y, Thoma F, West D, Serna-Gallegos D, Sultan I. Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annuli: A Propensity-Matched Analysis of Gender-Based Outcomes. Am J Cardiol 2024; 227:75-82. [PMID: 39059705 DOI: 10.1016/j.amjcard.2024.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Accepted: 07/20/2024] [Indexed: 07/28/2024]
Abstract
Patients with small aortic annuli (SAAs) are predominantly women. We sought to compare gender-based and propensity-matched outcomes of index transcatheter aortic valve replacement (TAVR) in patients with SAAs. In this retrospective institutional analysis (2012 to 2023), primary stratification was by gender. SAA was defined as an aortic valve annulus diameter <23 mm and the 30-day and 1-year outcomes were compared between the groups. A total of 3,911 patients underwent TAVR. Of those, 661 patients had an SAA, of whom 23.8% were men and 76.2% were women. Propensity matching (1:1) identified 152 pairs. The mean age was 81 years. History of surgical or percutaneous coronary intervention was more prevalent in men (72.4% vs 48%, p <0.001). Men had a higher incidence of postoperative pacemaker implantation (8.6% vs 3.3%, p = 0.05), whereas only women had iliofemoral dissections (4.6% vs 0%, p = 0.007). The rates of moderate (23.0% vs 25.7%) and severe (2.6% vs 0.7%) prosthesis-patient mismatch was not statistically significantly different between the groups (p = 0.364). The 30-day mortality was 0%, whereas the 1-year mortality was 4.3%, with no difference between the groups. An increase in preoperative creatinine was associated with higher risk of death (hazard ratio 1.206, 95% confidence interval 1.025 to 1.418, p = 0.02), whereas gender was not. Kaplan-Meier survival estimates (Log rank, p = 0.768) and cumulative incidence of stroke readmission (p = 0.842) were similar in both groups. In conclusion, the outcomes of TAVR in SAAs do not differ by gender, with safety and efficacy evident in men and women.
Collapse
Affiliation(s)
- Danial Ahmad
- Department of Cardiothoracic Surgery; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Michel Pompeu Sá
- Department of Cardiothoracic Surgery; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Amber Makani
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Department of Interventional Cardiology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Dustin Kliner
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Department of Interventional Cardiology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Catalin Toma
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Department of Interventional Cardiology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Elizabeth Christensen
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Yisi Wang
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Floyd Thoma
- UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - David West
- Department of Cardiothoracic Surgery; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Derek Serna-Gallegos
- Department of Cardiothoracic Surgery; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Ibrahim Sultan
- Department of Cardiothoracic Surgery; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
| |
Collapse
|
2
|
Johnston N, James SK, Lindhagen L, Ståhle E, Christersson C. Sex-specific aspects on prognosis after aortic valve replacement for aortic stenosis: a SWEDEHEART registry study. Open Heart 2024; 11:e002725. [PMID: 39043607 PMCID: PMC11268039 DOI: 10.1136/openhrt-2024-002725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 07/05/2024] [Indexed: 07/25/2024] Open
Abstract
OBJECTIVE To compare long-term cardiovascular (CV) outcomes between men and women with aortic stenosis (AS) undergoing aortic valve replacement (AVR) by the type of valve implant. METHODS The study population consisted of 14 123 non-selected patients with AS undergoing first-time AVR and included in the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies (SWEDEHEART) registry during 2008-2016. Comparisons were made between men and women and type of valve implant (ie, surgical implantation with a mechanical (mSAVR) (n=1 966) or biological valve (bioSAVR) (n=9 801)) or by a transcatheter approach (TAVR) (n=2 356). Outcomes included all-cause mortality, ischaemic stroke, major bleeding, thromboembolic events, heart failure and myocardial infarction, continuously adjusted for significant comorbidities and medical treatment. RESULTS In the mSAVR cohort, there were no significant sex differences in any CV events. In the bioSAVR cohort, a higher risk of death (HR: 1.14; 95% CI: 1.04 to 1.26, p=0.007) and major bleeding (HR: 1.41; 95% CI: 1.18 to 1.69, p<0.001) was observed in men. In the TAVR cohort, men suffered a higher risk of death (HR: 1.24; 95% CI: 1.07 to 1.45, p=0.005), major bleeding (HR: 1.35; 95% CI: 1.00 to 1.82, p=0.022) and thromboembolism (HR: 1.35, 95% CI: 1.00 to 1.82, p=0.047). CONCLUSION No significant long-term difference in CV events was noted between men and women undergoing AVR with a mechanical aortic valve. In both the bioSAVR and TAVR cohort, mortality was higher in men who also had an increased incidence of several other CV events.
Collapse
Affiliation(s)
- Nina Johnston
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala Clinical Research Center, Uppsala, Sweden
| | - Stefan K James
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala Clinical Research Center, Uppsala, Sweden
| | - Lars Lindhagen
- Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| | - Elisabeth Ståhle
- Department of Surgical Sciences, Thoracic Surgery, Uppsala University Hospital, Uppsala, Sweden
| | - Christina Christersson
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala Clinical Research Center, Uppsala, Sweden
| |
Collapse
|
3
|
Montonati C, Pellegrini D, d'Atri DO, Pellicano M, Briguglia D, Giannini F, De Blasio G, Guagliumi G, Tespili M, Ielasi A. A novel balloon-expandable transcatheter aortic valve bioprosthesis: Myval and Myval Octacor. Expert Rev Cardiovasc Ther 2024; 22:325-337. [PMID: 38970466 DOI: 10.1080/14779072.2024.2375345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 06/28/2024] [Indexed: 07/08/2024]
Abstract
INTRODUCTION Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.
Collapse
Affiliation(s)
- Carolina Montonati
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Dario Pellegrini
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Daniele Oreste d'Atri
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
- Cardiothoracic Department, Università Vita-Salute San Raffaele, Milan, Italy
| | - Mariano Pellicano
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Daniele Briguglia
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Francesco Giannini
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Giuseppe De Blasio
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Giulio Guagliumi
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Maurizio Tespili
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| | - Alfonso Ielasi
- U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy
| |
Collapse
|
4
|
Lopes V, Almeida PC, Moreira N, Ferreira LA, Teixeira R, Donato P, Gonçalves L. Computed tomography imaging in preprocedural planning of transcatheter valvular heart interventions. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024; 40:1163-1181. [PMID: 38780710 DOI: 10.1007/s10554-024-03140-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 05/13/2024] [Indexed: 05/25/2024]
Abstract
Cardiac Computed Tomography (CCT) has become a reliable imaging modality in cardiology providing robust information on the morphology and structure of the heart with high temporal and isotropic spatial resolution. For the past decade, there has been a paradigm shift in the management of valvular heart disease since previously unfavorable candidates for surgery are now provided with less-invasive interventions. Transcatheter heart valve interventions provide a real alternative to medical and surgical management and are often the only treatment option for valvular heart disease patients. Successful transcatheter valve interventions rely on comprehensive multimodality imaging assessment. CCT is the mainstay imaging technique for preprocedural planning of these interventions. CCT is critical in guiding patient selection, choice of procedural access, device selection, procedural guidance, as well as allowing postprocedural follow-up of complications. This article aims to review the current evidence of the role of CCT in the preprocedural planning of patients undergoing transcatheter valvular interventions.
Collapse
Affiliation(s)
- Vanessa Lopes
- Cardiology Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal.
| | - Pedro Carvalho Almeida
- Medical Imaging Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
| | - Nádia Moreira
- Cardiology Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
| | - Luís Amaral Ferreira
- Medical Imaging Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
| | - Rogério Teixeira
- Cardiology Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
- Faculty of Medicine, Univ Coimbra, Coimbra, Portugal
| | - Paulo Donato
- Medical Imaging Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
- Faculty of Medicine, Univ Coimbra, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Biomedical Imaging and Translation Research (CIBIT), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| | - Lino Gonçalves
- Cardiology Department, Hospitais da Universidade de Coimbra, Unidade Local de Saúde de Coimbra, Coimbra, Portugal
- Faculty of Medicine, Univ Coimbra, Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Faculty of Medicine, Univ Coimbra, Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), Univ Coimbra, Coimbra, Portugal
| |
Collapse
|
5
|
van Wely M, Rooijakkers M, Stens N, El Messaoudi S, Somers T, van Garsse L, Thijssen D, Nijveldt R, van Royen N. Paravalvular regurgitation after transcatheter aortic valve replacement: incidence, quantification, and prognostic impact. EUROPEAN HEART JOURNAL. IMAGING METHODS AND PRACTICE 2024; 2:qyae040. [PMID: 39045465 PMCID: PMC11195773 DOI: 10.1093/ehjimp/qyae040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Accepted: 04/21/2024] [Indexed: 07/25/2024]
Abstract
Transcatheter aortic valve replacement (TAVR) is the standard of care in aortic stenosis with results comparable to surgical aortic valve replacement. However, paravalvular regurgitation (PVR) is more common after TAVR. With the alteration of devices and implantation techniques, the incidence of moderate or more PVR has declined. Mild PVR is still common in around 30% of TAVR patients in low-risk trials. Progression of AS causes myocardial hypertrophy and varying degrees of diastolic dysfunction which may cause heart failure even in combination with small volumes of PVR. Any degree of PVR is associated with an increased risk of overall and cardiovascular mortality. Predictors of PVR are annular eccentricity, severe calcification of the aortic valve, bicuspid aortic valves, and type of prosthesis where balloon-expandable devices are associated with less PVR. PVR is diagnosed using echocardiography, aortic angiogram with or without videodensitometry, haemodynamic parameters, or cardiac magnetic resonance. PVR can be treated using post-dilation, interventional treatment using a vascular plug, or implantation of a second device. Successful post-dilation depends on balloon size which should at least be equal to or >95% of the mean annulus diameter. Implantation of a second device to reduce PVR is successful in ∼90% of cases, either through lengthening of the sealing skirt in case of inadequate position or through further expansion of the index device. Implantation of a vascular plug can successfully reduce PVR and reduce mortality.
Collapse
Affiliation(s)
- Marleen van Wely
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Maxim Rooijakkers
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Niels Stens
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
- Department of Physiology, Radboudumc , Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Saloua El Messaoudi
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Tim Somers
- Department of Cardiothoracic Surgery, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Leen van Garsse
- Department of Cardiothoracic Surgery, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Dick Thijssen
- Department of Physiology, Radboudumc , Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Robin Nijveldt
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Niels van Royen
- Department of Cardiology, Radboudumc, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| |
Collapse
|
6
|
Mohamed AR, Alharbi A, Sajdeya O, Moustafa A, Younes S, Grande R. Left ventricular narrow-neck pseudoaneurysm following a redo mitral valve replacement. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024; 59:17-20. [PMID: 37391324 DOI: 10.1016/j.carrev.2023.06.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 05/31/2023] [Accepted: 06/23/2023] [Indexed: 07/02/2023]
Affiliation(s)
| | | | - Omar Sajdeya
- Department of Internal Medicine, The University of Toledo, Toledo, OH, USA
| | | | - Stephanie Younes
- Division of Cardiovascular Medicine, Promedica-Toledo Hospital, Toledo, OH, USA
| | - Robert Grande
- Division of Cardiovascular Medicine, Promedica-Toledo Hospital, Toledo, OH, USA
| |
Collapse
|
7
|
Aljabbary TF, Komatsu I, Ochiai T, Fremes SE, Ali N, Burke L, Peterson MD, Fam NP, Wijeysundera HC, Radhakrishnan S. Cusp overlap method for self-expanding transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2024; 103:202-208. [PMID: 38009641 DOI: 10.1002/ccd.30910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/27/2023] [Indexed: 11/29/2023]
Abstract
BACKGROUND Conduction disturbances and the need for permanent pacemaker (PPM) implantation remains a common complication for transcatheter aortic valve replacement (TAVR), particularly when self-expanding (SE) valves are used. AIMS We compared in-hospital and 30-day rates of new PPM implantation between patients undergoing TAVR with SE valves using the conventional three-cusp coplanar implantation technique and the cusp-overlap technique. METHODS We retrospectively compared patients without a pre-existing PPM who underwent a TAVR procedure with SE Evolut R or PRO valves using the cusp-overlap technique from July 2018 to September 2020 (n = 519) to patients who underwent TAVR using standard three-cusp technique from April 2016 to March 2017 (n = 128) in two high volume Canadian centers. RESULTS There was no significant difference in baseline RBBB between the groups (10.4% vs. 13.2; p = 0.35). The rate of in-hospital new complete heart block (9.4% vs. 23.4%; p ≤ 0.001) and PPM implantation (8% vs. 21%; p ≤ 0.001) were significantly reduced when using the cusp-overlap technique. The incidence of new LBBB (30.4% vs. 29%; p = 0.73) was similar. At 30 days, the rates of new complete heart block (11% vs. 23%; p ≤ 0.001) and PPM implantation (10% vs. 21%, p ≤ 0.001) remained significantly lower in the cusp-overlap group, while the rate of new LBBB (35% vs. 30%; p = 0.73) was similar. CONCLUSION Cusp-overlap approach offers several potential technical advantages compared to standard three-cusp view, and may result in lower PPM rates in TAVR with SE Evolut valve.
Collapse
Affiliation(s)
- Talal F Aljabbary
- Schulich Heart Program, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Canada
- Department of Cardiac Sciences, King Fahad Cardiac Center, College of Medicine, King Saud University, Riyadh, Saudi Arabia
| | - Ikki Komatsu
- Department of Cardiology, Tokyo Medical University Hospital, Tokyo, Japan
| | - Tomoki Ochiai
- Schulich Heart Program, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Canada
- Department of Cardiology, Shonan Kamakura General Hospital, Kamakura, Kanagawa, Japan
| | - Stephen E Fremes
- Schulich Heart Program, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Canada
| | - Noman Ali
- Division of Cardiology, Terrence Donnelly Heart Center, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada
| | - Lucas Burke
- Division of Cardiology, Terrence Donnelly Heart Center, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada
| | - Mark D Peterson
- Division of Cardiology, Terrence Donnelly Heart Center, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada
| | - Neil P Fam
- Division of Cardiology, Terrence Donnelly Heart Center, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada
| | - Harindra C Wijeysundera
- Schulich Heart Program, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Canada
| | - Sam Radhakrishnan
- Schulich Heart Program, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Canada
| |
Collapse
|
8
|
Amien B, Appleby C, Mills J, Sandhu K, Harrington D. Acute Aortic Regurgitation After Transcatheter Aortic Valve Implantation Procedure. Cureus 2023; 15:e50345. [PMID: 38149064 PMCID: PMC10750444 DOI: 10.7759/cureus.50345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/11/2023] [Indexed: 12/28/2023] Open
Abstract
This study reports the case of a 75-year-old woman who developed aortic regurgitation (AR) a few hours after transcatheter aortic valve implantation (TAVI). The patient underwent the TAVI procedure for aortic stenosis and became hypotensive in recovery. A transthoracic echo revealed cardiac tamponade and around 1500 ml of blood was drained over several hours. Further advice was sought from the surgical team, and a transoesophageal echo revealed significant AR, which was confirmed by a transthoracic echo performed the next day. The patient underwent an emergency surgical aortic valve replacement. This case study demonstrates one of the complications of the TAVI procedure, acute AR, which was diagnosed a few hours after the procedure.
Collapse
Affiliation(s)
- Bothayna Amien
- Department of Cardiothoracic Surgery, Liverpool Heart and Chest Hospital, Liverpool, GBR
| | - Clare Appleby
- Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, GBR
| | - Joe Mills
- Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, GBR
| | - Kully Sandhu
- Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, GBR
| | - Deborah Harrington
- Department of Cardiothoracic Surgery, Liverpool Heart and Chest Hospital, Liverpool, GBR
| |
Collapse
|
9
|
Gooley R, Murdoch D, Ng MK, Modolo R, Allocco DJ. First results from the ACURATE Prime XL human feasibility study. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 57:1-5. [PMID: 37429793 DOI: 10.1016/j.carrev.2023.06.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/16/2023] [Accepted: 06/27/2023] [Indexed: 07/12/2023]
Abstract
BACKGROUND/PURPOSE This prospective, open-label, single-arm study evaluated transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis with ACURATE Prime XL, an iteration of the ACURATE neo2 device designed with improved radial force and adaptations for compatibility with a larger annulus diameter (≥ 26.5 mm and ≤ 29 mm based on pre-procedure diagnostic imaging). METHODS The composite primary device success endpoint was based on Valve Academic Research Consortium (VARC)-2 criteria. The primary safety endpoint was a composite of all-cause mortality and all stroke at 30 days. Aortic valve (AV) performance, including mean AV gradient, AV area, and grade of paravalvular leak (PVL), was assessed by an independent core laboratory. RESULTS 13 male patients were enrolled at 3 Australian centers (mean age: 83.1 years; 10 of 13 were considered high/extreme operative risk). 61.5 % of patients met the primary device success endpoint. At 30 days, no patients experienced death or stroke; one patient received a permanent pacemaker. Mean AV gradient improved from baseline (42.7 ± 11.0 mmHg) to discharge (7.7 ± 2.5 mmHg) and through 30 days (7.2 ± 2.3 mmHg). Mean AV area was 0.8 ± 0.1 cm2 at baseline, 1.9 ± 0.3 cm2 at discharge, and 1.7 ± 0.3 cm2 at 30 days. Per core-laboratory adjudication, no patient had moderate or severe PVL at 30 days; 91.7 % had no/trace PVL and 8.3 % had mild PVL. CONCLUSIONS AND RELEVANCE In this first-in-human feasibility study of the ACURATE Prime XL valve, there were no safety concerns, and no deaths or strokes within 30 days. Valve hemodynamics were favorable, and no patient had >mild PVL.
Collapse
Affiliation(s)
- Robert Gooley
- Monash Heart, Monash Health, Clayton, Victoria, Australia.
| | - Dale Murdoch
- The Prince Charles Hospital, Faculty of Medicine, University of Queensland, Brisbane, Queensland, Australia.
| | - Martin K Ng
- Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.
| | | | | |
Collapse
|
10
|
Ahmed A, Awad AK, Varghese KS, Mathew J, Huda S, George J, Mathew S, Abdelnasser OA, Awad AK, Mathew DM. Minimally Invasive Versus Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis and Systematic Review. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2023; 18:424-434. [PMID: 37658743 DOI: 10.1177/15569845231197224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
OBJECTIVE Transcatheter aortic valve replacement (TAVR) has arisen as a viable alternative to surgery. Similarly, minimally invasive surgical aortic valve replacement (mini-SAVR), such as ministernotomy and minithoracotomy, have also gained interest. We conducted a pairwise meta-analysis to further investigate the efficacy of TAVR versus mini-SAVR. METHODS Medical databases were comprehensively searched for studies comparing TAVR with a mini-SAVR modality, defined as minimally invasive aortic surgery, ministernotomy, minithoracotomy, or rapid-deployment or sutureless SAVR. Random-effects meta-analysis was conducted using the generic inverse variance method. Primary outcomes included 30-day mortality, midterm mortality, 30-day stroke, acute kidney injury (AKI), paravalvular leak (PVL), new permanent pacemaker (PPM), new-onset atrial fibrillation, and postintervention mean and peak valve pressure gradients and were pooled as risk ratio (RR), mean difference (MD), or hazard ratio (HR) with 95% confidence interval (CI). RESULTS A total of 5,071 patients (2,505 mini-SAVR vs 2,566 TAVR) from 12 studies were pooled. Compared with TAVR, mini-SAVR showed significantly lower rates of both 30-day (RR = 0.63, 95% CI: 0.42 to 0.96, P = 0.03) and midterm mortality at 4 years of follow-up (HR = 0.76, 95% CI: 0.67 to 0.87, P < 0.001). Furthermore, mini-SAVR was protective against 30-day PVL (RR = 0.07, 95% CI: 0.04 to 0.13, P < 0.001) and new PPM (RR = 0.25, 95% CI: 0.11 to 0.57, P < 0.001). Conversely, TAVR was protective against 30-day AKI (RR = 1.67, 95% CI: 1.20 to 2.32, P = 0.002) and postinterventional mean gradients (MD = 1.65, 95% CI: 0.25 to 3.05, P = 0.02). No difference was observed for 30-day stroke (RR = 0.84, 95% CI: 0.56 to 1.24, P = 0.38), new-onset atrial fibrillation (RR = 1.79, 95% CI: 0.93 to 3.44, P = 0.08), or postinterventional peak gradients (MD = 3.24, 95% CI: -1.10 to 7.59, P = 0.14). CONCLUSIONS Compared with TAVR, mini-SAVR was protective against 30-day and midterm mortality, 30-day PVL, and new permanent pacemaker, while TAVR patients had lower 30-day AKI. Future randomized trials comparing the efficacy of mini-SAVR approaches with TAVR are needed.
Collapse
Affiliation(s)
- Adham Ahmed
- City University of New York School of Medicine, NY, USA
| | - Ahmed K Awad
- Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | | | - Joshua Mathew
- City University of New York School of Medicine, NY, USA
| | - Shayan Huda
- City University of New York School of Medicine, NY, USA
| | - Jerrin George
- City University of New York School of Medicine, NY, USA
| | - Serena Mathew
- City University of New York School of Medicine, NY, USA
| | | | - Ayman K Awad
- Faculty of Medicine, El-Galala University, Suez, Egypt
| | - Dave M Mathew
- City University of New York School of Medicine, NY, USA
| |
Collapse
|
11
|
Pitta Gros B, Roux O, Eeckhout E, Kirsch M. Case report: Stenosis turned leak … and turned stenosis-complications of paravalvular prosthetic leak closure with a plug device. Front Cardiovasc Med 2023; 10:1132063. [PMID: 37378399 PMCID: PMC10292925 DOI: 10.3389/fcvm.2023.1132063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Accepted: 05/22/2023] [Indexed: 06/29/2023] Open
Abstract
Background Paravalvular leak is one of the most common complications and is among the most important prognostic factors of short- and long-term mortality after transcatheter aortic valve implantation (TAVI). Percutaneous valvular leak repair constitutes a first-line treatment for paravalvular leaks and is associated with high success rates and few serious complications nowadays. To the best of our knowledge, this is the first case where placement of the device through the stenting of the bioprosthesis resulted in creating a new symptomatic stenosis that required surgery. Case summary We present a case of a patient with low-flow, low-gradient aortic stenosis treated with transfemoral implantation of a biological aortic prosthesis. One month after the procedure, the patient presented with acute pulmonary oedema and a paravalvular leak was discovered, which was corrected by percutaneous repair with a plug device. Five weeks after the valvular leak repair, the patient was readmitted for heart failure. At this time, a new aortic stenosis and paravalvular leak were diagnosed and the patient was referred for surgery. The new aortic mixed diseased was caused by the positioning of the plug device through the valve's metal stenting, which resulted in a paravalvular leak and pressed against the valve's leaflets, causing valvular stenosis. The patient was referred for surgical replacement and evolved well afterward. Conclusion This case illustrates a rare complication of a complex procedure, and it highlights the need for multidisciplinary decisions and good cooperation between the cardiology and cardiac surgery teams to develop better criteria in the selection of the appropriate technique for managing paravalvular leaks after TAVI.
Collapse
Affiliation(s)
- Barbara Pitta Gros
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
- University of Lausanne, Lausanne, Switzerland
| | - Olivier Roux
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Eric Eeckhout
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
- University of Lausanne, Lausanne, Switzerland
| | - Matthias Kirsch
- University of Lausanne, Lausanne, Switzerland
- Department of Cardiac Surgery, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
12
|
Shi J, Li W, Zhang T, Han C, Wang Z, Pei X, Li X, Zhao Z, Wang P, Han J, Chen S. Quantity and location of aortic valve calcification predicts paravalvular leakage after transcatheter aortic valve replacement: a systematic review and meta-analysis. Front Cardiovasc Med 2023; 10:1170979. [PMID: 37293280 PMCID: PMC10244734 DOI: 10.3389/fcvm.2023.1170979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 05/09/2023] [Indexed: 06/10/2023] Open
Abstract
Introduction Transcatheter aortic valve replacement (TAVR) is the first-line treatment for patients with moderate-to-high surgical risk of severe aortic stenosis. Paravalvular leakage (PVL) is a serious complication of TAVR, and aortic valve calcification contributes to the occurrence of PVL. This study aimed to investigate the effect of location and quantity of calcification in the aortic valve complex (AVC) and left ventricular outflow tract (LVOT) on PVL after TAVR. Method We performed a systematic review and meta-analysis to evaluate the effect of quantity and location of aortic valve calcification on PVL after TAVR using observational studies from PubMed and EMBASE databases from inception to February 16, 2022. Results Twenty-four observational studies with 6,846 patients were included in the analysis. A high quantity of calcium was observed in 29.6% of the patients; they showed a higher risk of significant PVL. There was heterogeneity between studies (I2 = 15%). In the subgroup analysis, PVL after TAVR was associated with the quantity of aortic valve calcification, especially those located in the LVOT, valve leaflets, and the device landing zone. A high quantity of calcium was associated with PVL, regardless of expandable types or MDCT thresholds used. However, for valves with sealing skirt, the amount of calcium has no significant effect on the incidence of PVL. Conclusion Our study elucidated the effect of aortic valve calcification on PVL and showed that the quantity and location of aortic valve calcification can help predict PVL. Furthermore, our results provide a reference for the selection of MDCT thresholds before TAVR. We also showed that balloon-expandable valves may not be effective in patients with high calcification, and valves with sealing skirts instead of those without sealing skirts should be applied more to prevent PVL from happening. Systematic Review Registration https://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=354630, identifier: CRD42022354630.
Collapse
Affiliation(s)
- Jiale Shi
- Shandong Provincial Hospital, Shandong University, Jinan, China
- Department of Second Clinical Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Wei Li
- Department of Second Clinical Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
- Department of Basic Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Tangshan Zhang
- Department of Vascular Surgery, Jiyang District People's Hospital, Jinan, China
| | - Chengwen Han
- Department of Second Clinical Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
- Department of Basic Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Zhengjun Wang
- Department of Cardiovascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Xinhao Pei
- Department of Basic Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Xuetao Li
- Department of Second Clinical Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Zidong Zhao
- Department of Public Health School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Pengbo Wang
- Department of Public Health School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Jingying Han
- Department of Basic Medical School, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Shiqiao Chen
- Department of Interventional Diagnosis and Treatment, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| |
Collapse
|
13
|
Methangkool E, Rong LQ, Neuburger PJ. Recommendations for Transesophageal Echocardiographic Screening in Transcatheter Aortic Valve Replacement: Insights for the Cardiothoracic Anesthesiologist. J Cardiothorac Vasc Anesth 2023; 37:679-682. [PMID: 36822889 DOI: 10.1053/j.jvca.2023.01.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 01/22/2023] [Indexed: 01/30/2023]
Affiliation(s)
- Emily Methangkool
- Department of Anesthesiology and Perioperative Medicine, David Geffen School of Medicine at University of California-Las Angeles, Los Angeles, CA
| | - Lisa Q Rong
- Department of Anesthesiology, Weil Cornell Medicine, New York, NY
| | - Peter J Neuburger
- Department of Anesthesiology, Perioperative Care and Pain Medicine, NYU Grossman School of Medicine, New York, NY.
| |
Collapse
|
14
|
Russo G, Tang GHL, Sangiorgi G, Pedicino D, Enriquez-Sarano M, Maisano F, Taramasso M. Lifetime Management of Aortic Stenosis: Transcatheter Versus Surgical Treatment for Young and Low-Risk Patients. Circ Cardiovasc Interv 2022; 15:915-927. [PMID: 36378737 DOI: 10.1161/circinterventions.122.012388] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Transcatheter aortic valve replacement is now indicated across all risk categories of patients with symptomatic severe aortic stenosis and has been proposed as first line option for the majority of patients >74 years old. However, median age of patients enrolled in the transcatheter aortic valve replacement low-risk trials is 74 years and transcatheter aortic valve replacement has never been systematically investigated in young low risk patients. Although the long-term data in surgical aortic valve replacement in young patients (age <75) are well known, such data remain lacking in transcatheter aortic valve replacement. In the absence of clear guideline recommendations in patients with challenging anatomies (eg, hostile calcium, bicuspid), it is important to know the potential advantages and disadvantages of each treatment and to consider how they might integrate with each other in the lifetime management of such patients. In this review, we discuss current outstanding issues on the management of severe aortic stenosis from a lifetime management perspective, particularly in terms of initial intervention and future reinterventions.
Collapse
Affiliation(s)
- Giulio Russo
- Department of Biomedicine and Prevention, Policlinico Tor Vergata, Rome (G.R., G.S.)
| | - Gilbert H L Tang
- Department of Cardiovascular Surgery, Mount Sinai Health System, New York (G.H.L.T.)
| | - Giuseppe Sangiorgi
- Department of Biomedicine and Prevention, Policlinico Tor Vergata, Rome (G.R., G.S.)
| | - Daniela Pedicino
- Fondazione Policlinico Universitario A Gemelli IRCSS, Roma, Italia (D.P.).,Università Cattolica del Sacro Cuore, Roma, Italia (D.P.)
| | | | | | | |
Collapse
|
15
|
Nappi F, Avtaar Singh SS, Nappi P, Fiore A. Biomechanics of Transcatheter Aortic Valve Implant. Bioengineering (Basel) 2022; 9:bioengineering9070299. [PMID: 35877350 PMCID: PMC9312295 DOI: 10.3390/bioengineering9070299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/28/2022] [Accepted: 06/29/2022] [Indexed: 11/16/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has grown exponentially within the cardiology and cardiac surgical spheres. It has now become a routine approach for treating aortic stenosis. Several concerns have been raised about TAVI in comparison to conventional surgical aortic valve replacement (SAVR). The primary concerns regard the longevity of the valves. Several factors have been identified which may predict poor outcomes following TAVI. To this end, the lesser-used finite element analysis (FEA) was used to quantify the properties of calcifications which affect TAVI valves. This method can also be used in conjunction with other integrated software to ascertain the functionality of these valves. Other imaging modalities such as multi-detector row computed tomography (MDCT) are now widely available, which can accurately size aortic valve annuli. This may help reduce the incidence of paravalvular leaks and regurgitation which may necessitate further intervention. Structural valve degeneration (SVD) remains a key factor, with varying results from current studies. The true incidence of SVD in TAVI compared to SAVR remains unclear due to the lack of long-term data. It is now widely accepted that both are part of the armamentarium and are not mutually exclusive. Decision making in terms of appropriate interventions should be undertaken via shared decision making involving heart teams.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord, 93200 Saint-Denis, France
- Correspondence: ; Tel.: +33-149334104; Fax: +33-149334119
| | | | - Pierluigi Nappi
- Department of Clinical and Experimental Medicine, University of Messina, 98122 Messina, Italy;
| | - Antonio Fiore
- Department of Cardiac Surgery, Hôpitaux Universitaires Henri Mondor, Assistance Publique-Hôpitaux de Paris, 94000 Creteil, France;
| |
Collapse
|
16
|
Kim WK, Thiele H, Linke A, Kuntze T, Fichtlscherer S, Webb J, Chu MWA, Adam M, Schymik G, Geisler T, Kharbanda R, Christen T, Allocco D. Transcatheter Aortic Valve Implantation with ACURATE neo: Results from the PROGRESS PVL Registry. J Interv Cardiol 2022; 2022:9138403. [PMID: 35832535 PMCID: PMC9252754 DOI: 10.1155/2022/9138403] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 03/18/2022] [Accepted: 05/03/2022] [Indexed: 11/29/2022] Open
Abstract
Objectives The PROGRESS PVL registry evaluated transcatheter aortic valve implantation (TAVI) in patients treated with ACURATE neo, a supra-annular self-expanding bioprosthetic aortic valve. Background While clinical outcomes with TAVI are comparable with those achieved with surgery, residual aortic regurgitation (AR) and paravalvular leak (PVL) are common complications. The ACURATE neo valve has a pericardial sealing skirt designed to minimize PVL. Methods The primary endpoint was the rate of total AR over time, as assessed by a core echocardiographic laboratory. The study enrolled 500 patients (mean age: 81.8 ± 5.1 years; 61% female; mean baseline STS score: 6.0 ± 4.5%) from 22 centers in Europe and Canada; 498 patients were treated with ACURATE neo. Results The rate of ≥ moderate AR was 4.6% at discharge and 3.1% at 12 months; the rate of ≥ moderate PVL was 4.6% at discharge and 2.6% at 12 months. Paired analyses showed significant improvement in overall PVL between discharge and 12 months (P < 0.001); 64.6% of patients had no change in PVL grade, 24.9% improved, and 10.5% worsened. Patients also exhibited significant improvement in transvalvular gradient (P < 0.001) and effective orifice area (P=0.01). The mortality rate was 2.2% at 30 days and 11.3% at 12 months. The permanent pacemaker implantation (PPI) rate was 10.2% at 30 days and 12.2% at 12 months. Conclusions Results from PROGRESS PVL support the sustained safety and performance of TAVI with the ACURATE neo valve, showing excellent valve hemodynamics, good clinical outcomes, and significant interindividual improvement in PVL from discharge to 12-month follow-up.
Collapse
Affiliation(s)
- Won-Keun Kim
- Department of Cardiology and Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Holger Thiele
- Department of Cardiology, Heart Center Leipzig at University of Leipzig and Leipzig Heart Institute, Leipzig, Germany
| | - Axel Linke
- Department of Internal Medicine and Cardiology, Herzzentrum Dresden at Technische Universität Dresden, Dresden, Germany
| | - Thomas Kuntze
- Department of Cardiology, Heart Centre, Central Clinic in Bad Berka, Bad Berka, Germany
| | - Stephan Fichtlscherer
- Department of Internal Medicine, Division of Cardiology, Johann W. Goethe University, Frankfurt, Germany
| | - John Webb
- Centre for Heart Valve Innovation, St. Paul's and Vancouver General Hospitals, University of British Columbia, Vancouver, British Columbia, Canada
| | - Michael W. A. Chu
- Division of Cardiac Surgery, Department of Surgery, Western University, London Health Sciences Centre, London, Ontario, Canada
| | - Matti Adam
- Clinic for Cardiology, University Hospital Cologne, Cologne, Germany
| | - Gerhard Schymik
- Medical Clinic IV, Department of Cardiology, Municipal Hospital Karlsruhe, Karlsruhe, Baden-Württemberg, Germany
| | - Tobias Geisler
- Department of Cardiology and Angiology, University Hospital Tübingen, Tübingen, Germany
| | | | | | | |
Collapse
|
17
|
Randall M, Betageri O, Hanayneh S, Anderson RD. Paravalvular Leak: A Systemic Review. Curr Cardiol Rev 2022; 18:e110522204571. [PMID: 35546743 PMCID: PMC9893144 DOI: 10.2174/1573403x18666220511113310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/10/2022] [Accepted: 03/15/2022] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Paravalvular Leak (PVL) refers to the retrograde flow of blood in the space between an implanted cardiac valve and native tissue. These are unfortunately but luckily relatively uncommon complications of prosthetic valve replacement that, especially when moderate or severe, have important clinical consequences. OBJECTIVE Addressing PVL requires a multidisciplinary team to properly diagnose this process and choose the corrective option most likely to result in success. METHODS A comprehensive literature search was undertaken to formulate this narrative review. RESULTS This review highlights the complex nature of PVL and the promising contemporary treatments available. CONCLUSION Clinicians should be adept at recognizing PVL and characterizing it using multimodality imaging. Using the many available tools and a multidisciplinary approach should lead to favorable outcomes in patients with PVL.
Collapse
Affiliation(s)
- Morgan Randall
- Division of Cardiovascular Medicine, Department of Medicine, University of Florida, Gainesville, FL 32611, USA
| | - Omkar Betageri
- Department of Medicine, University of Florida, Gainesville, FL 32611, USA
| | - Seri Hanayneh
- Department of Medicine, University of Florida, Gainesville, FL 32611, USA
| | - R. David Anderson
- Division of Cardiovascular Medicine, Department of Medicine, University of Florida, Gainesville, FL 32611, USA
| |
Collapse
|
18
|
Xuan Y, Dvir D, Wisneski AD, Wang Z, Ye J, Guccione JM, Ge L, Tseng EE. Impact of Transcatheter Aortic Valve Size on Leaflet Stresses: Implications for Durability and Optimal Grey Zone Sizing. ACTA ACUST UNITED AC 2021; 6:64-71. [PMID: 34708162 DOI: 10.4244/aij-d-19-00005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Aims As indications for transcatheter aortic valve replacement (TAVR) continue to expand towards younger and lower-risk patients, durability becomes an increasingly important question. Durability decreases as leaflet stresses increase, but the impact of transcatheter heart valve (THV) size on stress is unknown. Patient annulus sizes can fall within "grey zones" between 2 TAVR sizes. Our aim was to examine the impact of balloon-expandable THV size on leaflet stresses. Methods and Results SapienXT 23mm, 26mm, and 29mm sizes (Edwards Lifesciences, Inc) underwent micro-computed tomography scanning to create THV computational models then loaded to systemic pressure using finite element software. THV leaflet maximum principal stresses were 1.69MPa (23mm), 1.70MPa (26mm), and 2.12MPa (29mm) at mean arterial pressure. For intermediate annulus sizes, undersizing the larger THV yielded lower leaflet stresses than oversizing the smaller THV. Conclusions Increasing THV size yielded greater leaflet maximum principal stresses, which could suggest a relationship between THV size and long-term durability.. For annulus "grey zones" sizes, undersizing the larger THV resulted in lower leaflet stresses than oversizing the smaller THV. These results may influence optimal device sizing, as THV durability remains an important, unanswered question.
Collapse
Affiliation(s)
- Yue Xuan
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Danny Dvir
- Division of Cardiology, University of Washington, Seattle, WA
| | - Andrew D Wisneski
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Zhongjie Wang
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Jian Ye
- Division of Cardiovascular Surgery, St. Paul's Hospital and Vancouver General Hospital, Vancouver, BC, Canada
| | - Julius M Guccione
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Liang Ge
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| | - Elaine E Tseng
- Department of Surgery, University of California San Francisco and San Francisco VA Medical Centers, San Francisco, CA
| |
Collapse
|
19
|
Bricker RS, Cleveland JC, Messenger JC. Mechanical Complications of Transcatheter Aortic Valve Replacement. Interv Cardiol Clin 2021; 10:465-480. [PMID: 34593110 DOI: 10.1016/j.iccl.2021.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Mechanical complications after transcatheter aortic valve replacement are fortunately rare with the current generation of devices. Unfortunately, life-threatening complications will occur and it is the responsibility of operators to be familiar with strategies to prevent and manage these challenging scenarios. Because these cases will not occur often, it is important for us to highlight and talk about those that do occur, to learn best practices in how to manage and prevent them going forward. We can learn much from each other's good crash landings.
Collapse
Affiliation(s)
- Rory S Bricker
- Department of Medicine, Division of Cardiology, University of Colorado School of Medicine, 12631 East 17th Avenue, B130, Aurora, CO 80045, USA
| | - Joseph C Cleveland
- Department of Surgery, Division of Cardiothoracic Surgery, University of Colorado School of Medicine, 12631 East 17th Avenue, 6111, Aurora, CO 80045, USA
| | - John C Messenger
- Department of Medicine, Division of Cardiology, University of Colorado School of Medicine, 12631 East 17th Avenue, B130, Aurora, CO 80045, USA.
| |
Collapse
|
20
|
Alvarado T, Rivero F, Diego G, García-Guimaraes M, Salamanca J, Díez-Villanueva P, Cuesta J, Antuña P, Jiménez-Borreguero J, Alfonso F. Transcatheter aortic valve replacement using the new Evolut-Pro system: a prospective comparison with the Evolut-R device. J Thorac Dis 2021; 13:4023-4032. [PMID: 34422332 PMCID: PMC8339791 DOI: 10.21037/jtd-20-2409] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 05/12/2021] [Indexed: 11/25/2022]
Abstract
Background Evolut Pro (EVP) is a novel self-expandable aortic valve. This prosthesis consists of an external porcine pericardial wrap designed to reduce paravalvular leak (PVL), maintaining the benefits of its predecessor, the Evolut R (EVR). The aim was to compare the functional and clinical results in the short and medium term of the new EVP with the EVR system. Methods Consecutive patients receiving either the EVR (n=50) or the EVP (n=33) from June 2015 to October 2018 were compared. Baseline characteristics, cardiovascular imaging, procedural outcomes, short and mid-term follow-up outcomes were prospectively collected and assessed. Results Residual mild PVL was common and comparable in the two groups (EVR 79% vs. EVP 70%; P=0.4). In the EVR group, the presence of PVL was directly related to prosthesis size, but this correlation was not observed in the EVP group. Conduction abnormalities were more prevalent with the EVP, but these did not translate into a higher need of permanent pacemaker implantation. Vascular and bleeding complications were infrequent in both groups. At mid-term clinical follow-up (median survival time: EVR 11±0.3 months, EVP 12±0.2 months), the 1-year rate of adverse events was similar (EVR: 24%, EVP: 33%; P=0.3). Conclusions Both protheses are effective for the treatment of severe aortic stenosis with excellent results at mid-term clinical follow up. The EVP remains associated with a significant rate of residual mild PVL that appears to be similar to that observed with EVR.
Collapse
Affiliation(s)
- Teresa Alvarado
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | - Fernando Rivero
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | - Guillermo Diego
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | | | - Jorge Salamanca
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | | | - Javier Cuesta
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | - Paula Antuña
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| | | | - Fernando Alfonso
- Department of Cardiology, Hospital Universitario de La Princesa, Madrid, Spain
| |
Collapse
|
21
|
Wang R, Kawashima H, Mylotte D, Rosseel L, Gao C, Aben JP, Abdelshafy M, Onuma Y, Yang J, Soliman O, Tao L, Serruys PW. Quantitative Angiographic Assessment of Aortic Regurgitation After Transcatheter Implantation of the Venus A-valve: Comparison with Other Self-Expanding Valves and Impact of a Learning Curve in a Single Chinese Center. Glob Heart 2021; 16:54. [PMID: 34381675 PMCID: PMC8344958 DOI: 10.5334/gh.1046] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 07/20/2021] [Indexed: 01/14/2023] Open
Abstract
Objectives We aimed to compare the quantitative angiographic aortic regurgitation (AR) into the left ventricular out flow tract (LVOT-AR) of five different types of transcatheter self-expanding valves and to investigate the impact of the learning curve on post-TAVR AR. Background Quantitative video densitometric aortography is an objective, accurate, and reproducible tool for assessment of AR following TAVR. Methods and results This retrospective academic core-lab analysis, analyzed 1150 consecutive cine aortograms performed immediately post-TAVR. Quantitative angiographic AR of post-procedural aortography in 181 consecutive patients, who underwent TAVR with the Venus A-valve in a single Chinese center, were compared to the results of Evolut Pro, Evolut R, CoreValve, (Medtronic, Dublin, Ireland) and Acurate Neo (Boston Scientific, Massachusetts, US) transcatheter heart valves (THVs), from a previously published pooled database. Among the 181 aortograms of patients treated with the Venus A-Valve, 113 (62.4%) were analyzable for quantitative assessment of AR. The mean LVOT-AR was 8.9% ± 10.0% with 14.2% of patients having moderate or severe AR in the Venus A-valve group. No significant difference in mean LVOT-AR was observed between Evolut Pro, Evolut R, Acurate Neo, and Venus A-valve. The incidence of LVOT-AR >17%, which correlates with echocardiographic derived ≥ moderate AR, with the Evolut Pro was lower than with the Venus A-valve (5.3% vs. 14.2%, p = 0.034), but was not different from the Evolut R (5.3% vs. 8.8%, p = 0.612), or the Acurate Neo (5.3% vs. 11.3% p = 0.16) systems. A landmark analysis after recruitment of the first half of patients treated with the Venus A valve (N = 56), showed a significantly lower mean LVOT-AR in the second half of the series (11.3% ± 11.9% vs. 6.5% ± 7.1%, p = 0.011). The incidence of LVOT-AR >17% in the latest 57 cases was also numerically lower (7.0% vs. 21.4%, p = 0.857) and compared favorably with the best in class of the self-expanding valves. Conclusion The Venus A-valve has comparable mean LVOT-AR to other self-expanding valves but has a higher rate of moderate or severe AR than the Evolut Pro THV. However, after completion of a learning phase, results improved and compared favorably with the best in class of the commercially available self-expanding valves. These findings should be confirmed in prospective randomized comparisons of AR between different THVs.
Collapse
Affiliation(s)
- Rutao Wang
- Department of Cardiology, Xijing Hospital, Xi’an, CN
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
- Department of Cardiology, Radboud University Medical Center, Nijmegen, NL
| | - Hideyuki Kawashima
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
- Amsterdam UMC, University of Amsterdam, Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, NL
| | - Darren Mylotte
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
| | - Liesbeth Rosseel
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
| | - Chao Gao
- Department of Cardiology, Xijing Hospital, Xi’an, CN
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
- Department of Cardiology, Radboud University Medical Center, Nijmegen, NL
| | | | - Mahmoud Abdelshafy
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
| | - Yoshinobu Onuma
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
| | - Jian Yang
- Department of Cardiovascular Surgery, Xijing Hospital, Xi’an, CN
| | - Osama Soliman
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
| | - Ling Tao
- Department of Cardiology, Xijing Hospital, Xi’an, CN
| | - Patrick W. Serruys
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway and CORRIB Research Center for Advanced Imaging and Core laboratory, IE
- NHLI, Imperial College London, London, UK
| |
Collapse
|
22
|
Wunderlich NC, Honold J, Swaans MJ, Siegel RJ. How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement. Curr Cardiol Rep 2021; 23:94. [PMID: 34196775 DOI: 10.1007/s11886-021-01522-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/14/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE OF REVIEW In this review, we provide an overview of potential prosthesis - related complications after transcatheter aortic valve replacement, their incidences, the imaging modalities best suited for detection, and possible strategies to manage these complications. RECENT FINDINGS Therapy for severe aortic valve stenosis requiring intervention has increasingly evolved toward transcatheter aortic valve replacement over the past decade, and the number of procedures performed has increased steadily in recent years. As more and more centers favor a minimalistic approach and largely dispense with general anesthesia and intra-procedural imaging by transesophageal echocardiography, post-procedural imaging is becoming increasingly important to promptly detect dysfunction of the transcatheter valve and potential complications. Complications after transcatheter aortic valve replacement must be detected immediately in order to initiate adequate therapeutic measures, which require a profound knowledge of possible complications that may occur after transcatheter aortic valve replacement, the imaging modalities best suited for detection, and available treatment options.
Collapse
Affiliation(s)
| | - Jörg Honold
- Cardiovascular Center Darmstadt, Darmstadt, Germany
| | - Martin J Swaans
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands
| | - Robert J Siegel
- Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| |
Collapse
|
23
|
Mahon C, Davies A, Gambaro A, Musella F, Costa AL, Panoulas V, Nicol E, Duncan A, Davies S, Mirsadraee S. Association of individual aortic leaflet calcification on paravalvular regurgitation and conduction abnormalities with self-expanding trans-catheter aortic valve insertion. Quant Imaging Med Surg 2021; 11:1970-1982. [PMID: 33936979 DOI: 10.21037/qims-20-1122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Complication rates of paravalvular aortic regurgitation (PVR) and permanent pacemaker insertion remain high in patients undergoing trans-catheter aortic valve insertion for severe aortic stenosis. The spatial distribution of calcium between individual aortic valve leaflets, and its potential role in these complications is gaining interest. We aimed to assess the accuracy of individual aortic valve leaflet calcium quantification, and to determine its effect on the frequency of these complications. Methods This was a retrospective study of 251 patients who underwent trans-catheter aortic valve insertion using the Evolut RTM valve. The off-line Terarecon software platform was used for Agatston scoring the short axis views. Results There was a correlation between the sum of the individual leaflet and the total aortic valve calcium score. There was a univariate association between an increase [per 100 Agatston unit (AU)] in both right coronary leaflet (RCL) and left coronary leaflet (LCL) calcium with the risk of PVR. There was an association between an increase in LCL calcium score (per 100 AU) and need for post-implantation balloon aortic valvuloplasty (BAV). There was no association between individual leaflet calcification on the risk of permanent pacemaker insertion. Conclusions This study supports the idea that a quantifiable and reproducible method of individual valve leaflet calcification score may serve as an independent risk factor for paravalvular regurgitation, beyond visual assessment of asymmetry. However, the same may not be true of spatial calcium distribution and permanent pacemaker implantation (PPI).
Collapse
Affiliation(s)
- Ciara Mahon
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Allan Davies
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Alessia Gambaro
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | | | - Ana Luisa Costa
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | | | - Edward Nicol
- Royal Brompton and Harefield NHS Foundation Trust, London, UK.,National Heart and Lung Institute, Imperial College London, London, UK
| | - Alison Duncan
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Simon Davies
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | | |
Collapse
|
24
|
Brinkert M, De Boeck B, Stämpfli SF, Wolfrum M, Moccetti F, Attinger-Toller A, Bossard M, Cuculi F, Kobza R, Toggweiler S. Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study. Open Heart 2020; 7:openhrt-2020-001391. [PMID: 33243930 PMCID: PMC7692991 DOI: 10.1136/openhrt-2020-001391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 09/05/2020] [Accepted: 10/19/2020] [Indexed: 11/25/2022] Open
Abstract
Objectives Report predictors and the natural course of paravalvular leak (PVL) following implantation of the ACURATE neo transcatheter heart valve (THV). Background Understanding the mechanisms of PVL may help to improve patient selection, patient outcomes and the design of next-generation THVs. Methods A total of 30 patients (mean age 81±5 years, 47% women) undergoing transcatheter aortic valve replacement with the ACURATE neo were enrolled in the PREDICT PVL study. The effective regurgitant orifice area (EROA, in mm2) of PVL was assessed by transthoracic and transoesophageal echocardiography before discharge and at 6 months follow-up. Results PVL was none/trace in 10 (33%), mild in 18 (60%) and moderate in 2 (7%) patients and occurred in distinct locations with largest EROAs in the area of the left coronary cusp and its adjacent commissures. Independent predictors for EROA were implantation depth (r coefficient −1.9 mm2 per mm implantation depth, p=0.01), leaflet calcification (6.2 mm2 per calcification grade, p=0.03) and THV size L (7.6 mm2 more than size S or M, p=0.01). At 6 months follow-up, EROA decreased by 29% from 13.7±9.7 mm2 to 9.5±7.9 mm2 (p<0.01). Patients with smaller EROAs were more likely to be in New York Heart Association class 1 than patients with larger EROAs (p<0.01). Conclusions PVL occurred predominantly in the region of the left coronary cusp and decreased by 29% during 6 months of follow-up. Our results underscore the importance of adequate patient selection and optimal implantation depth.
Collapse
Affiliation(s)
- Miriam Brinkert
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Bart De Boeck
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Simon F Stämpfli
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Mathias Wolfrum
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Federico Moccetti
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | | | - Matthias Bossard
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Florim Cuculi
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Richard Kobza
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| | - Stefan Toggweiler
- Cardiology Division, Heart Center, Luzerner Kantonsspital, Luzern, Switzerland
| |
Collapse
|
25
|
Modolo R, Chang CC, Onuma Y, Schultz C, Tateishi H, Abdelghani M, Miyazaki Y, Aben JP, Rutten MC, Pighi M, El Bouziani A, van Mourik M, Lemos PA, Wykrzykowska JJ, Brito FS, Sahyoun C, Piazza N, Eltchaninoff H, Soliman O, Abdel-Wahab M, Van Mieghem NM, de Winter RJ, Serruys PW. Quantitative aortography assessment of aortic regurgitation. EUROINTERVENTION 2020; 16:e738-e756. [DOI: 10.4244/eij-d-19-00879] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
26
|
Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis. IJC HEART & VASCULATURE 2020; 30:100593. [PMID: 32775601 PMCID: PMC7399118 DOI: 10.1016/j.ijcha.2020.100593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 06/21/2020] [Accepted: 07/13/2020] [Indexed: 11/23/2022]
Abstract
Transcatheter heart valve size selection is still challenging. The overlap between two different prosthesis sizes for borderline annuli remains. Undersizing but overfilling improves sizing in borderline annulus cases. Undersizing but overfilling decreases the postprocedural THV-pressure gradient. Prospective studies are needed considering the TAVR expansion to younger patients.
Background Current recommendations for valve size selection are based on multidimensional annular measurements, yet the overlap between two different transcatheter heart valve (THV) sizes remains. We sought to evaluate whether undersizing but overfilling eliminates the gray zones of valve sizing. Methods Data of 246 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable bioprosthesis with either conventional sizing and nominal filling (group 1 (NF-TAVR), n = 154) or undersizing but overfilling under a Less Is More (LIM)-Principle (group 2 (LIM-TAVR), n = 92) were compared. Paravalvular leakage (PVL) was graded angiographically and quantitatively using invasive hemodynamics. Results Annulus rupture (AR) occurred only in group 1 (n = 3). Due to AR adequate evaluation of PVL was possible in 152 patients of group 1. More than mild PVL was found in 13 (8.6%) patients of group 1 and 1 (1.1%) patient of group 2 (p = 0.019). Postdilatation was performed in 31 (20.1%) patients of group 1 and 6 patients (6.5%) of group 2 (p = 0.003). For patients with borderline annulus size in group 1 (n = 35, 22.7%) valve size selection was left to the physiciańs choice resulting in selection of the larger prosthesis in 10 (28.6%). In group 2 all patients with borderline annulus (n = 36, 39.1%) received the smaller prosthesis (LIM-TAVR). The postprocedural mean transvalvular pressure gradient was significantly higher in the NF-TAVR-group (11.7 ± 4 vs. 10.1 ± 3.6 mmHg, p = 0.005). Conclusion LIM-TAVR eliminates the gray zones of sizing and associated PVL, can improve THV-performance, reduce incidence of annular rupture and simplify the procedure especially in borderline cases.
Collapse
|
27
|
Piayda K, Hellhammer K, Veulemans V, Afzal S, Heidari H, Wimmer AC, Al Juburi M, Antoch G, Kelm M, Zeus T. Performance of the CoreValve Evolut R and PRO in Severely Calcified Anatomy: A Propensity Score Matched Analysis. Heart Lung Circ 2020; 29:1847-1855. [PMID: 32646637 DOI: 10.1016/j.hlc.2020.05.096] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 05/02/2020] [Accepted: 05/11/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND The CoreValve Evolut R and PRO (Medtronic, Minneapolis, MN, USA) are among the newest-generation of self-expandable transcatheter aortic valve replacement (TAVR) devices and show excellent results. Treating patients with severely calcified (SC) native aortic valve anatomy may be challenging because of the increased risk of periprocedural complications. This study investigated the performance of Evolut R and PRO in this special patient subset. METHODS Patients who underwent TAVR with the CoreValve Evolut R or PRO (n=381) from September 2015 to March 2018 were divided by aortic valve calcification extent. Patients with SC aortic valve anatomy (n=98; men, >2,062 and women, >1,377 Agatston units) were compared with those with non-severely calcified (NCS) aortic valve anatomy after 1:2 propensity score matching. Outcomes were evaluated according to the updated valve academic research consortium criteria. RESULTS Patients with SC anatomy were older (83 years vs 80 years, p<0.001) and had a smaller aortic valve area (0.63 cm2 vs 0.70 cm2, p=0.028). Pre-dilatation was more often performed (30.6% vs 15.8%, p=0.003) and a permanent pacemaker implantation was more often necessary (32.9% vs 8.8%, p<0.001) in the SC group. None/mild aortic regurgitation (AR) was evenly distributed (SC, 96.9% vs NCS, 99.5%, p=0.109); moderate AR was present in 3.1% of SC patients and in 0.5% of NSC patients. Severe AR was not observed. CONCLUSION The CoreValve Evolut R and PRO showed good clinical safety profiles and excellent haemodynamic results in patients with SC anatomy and who more often required permanent pacemaker implantation.
Collapse
Affiliation(s)
- Kerstin Piayda
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Katharina Hellhammer
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Verena Veulemans
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Shazia Afzal
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Houtan Heidari
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Anna Christina Wimmer
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Maryam Al Juburi
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Gerald Antoch
- Medical Faculty, Department of Diagnostic and Interventional Radiology, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Malte Kelm
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany; CARID (Cardiovascular Research Institute Düsseldorf), Düsseldorf, Germany
| | - Tobias Zeus
- Medical Faculty, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
| |
Collapse
|
28
|
Sellers SL, Sathananthan J, Bouchareb R, Mostaço-Guidolin LB, Lau KPL, Bugis J, Hensey M, Blanke P, Payne GW, Lebeche D, Pibarot P, Hackett TL, Webb JG, Leipsic JA. Impact of Over-Expansion on SAPIEN 3 Transcatheter Heart Valve Pericardial Leaflets. STRUCTURAL HEART 2020. [DOI: 10.1080/24748706.2020.1742950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
29
|
Ko TY, Kao HL, Chen YC, Lin LC, Liu YJ, Yeh CF, Huang CC, Chen YH, Chen YS, Lin MS. Temporal Change in Paravalvular Leakage after Transcatheter Aortic Valve Replacement with a Self-Expanding Valve: Impact of Aortic Valve Calcification. ACTA CARDIOLOGICA SINICA 2020; 36:140-147. [PMID: 32201465 DOI: 10.6515/acs.202003_36(2).20190709b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Background In patients undergoing transcatheter aortic valve replacement (TAVR), the severity of paravalvular leakage (PVL) may change during follow-up, however its mechanism is poorly understood. We aimed to explore temporal changes in PVL and possible predictors following TAVR. Methods A retrospective analysis was performed of all patients who had received a self-expanding valve. Multi-detector computed tomography was performed as pre-TAVR evaluation, including assessment of aortic valve calcification (AVC). The patients received transthoracic echocardiography at baseline and 30 days, 6 months, and 1 year after TAVR. Results In total, 93 patients who had received a self-expanding valve during TAVR were identified. Various degrees of PVL were seen in 63 patients, with moderate/severe PVL in 21 (22.6%). In multivariate analysis, the predictors of moderate/severe PVL were: chronic pulmonary disease, high degree of AVC, and an increased annulus perimeter. After 1 year of follow-up, PVL deteriorated from mild to moderate in 2 patients, while an improvement of ≥ 1 grade was seen in 25 patients. Of 21 patients with post-TAVR moderate/severe PVL, 9 had an improvement of ≥ 1 grade and 12 did not. The degree of AVC was significantly lower in those with PVL improvement (Agatston score 3068 ± 1816 vs. 6418 ± 3222; p = 0.01). AVC was a good predictor for an improvement in PVL, and the area under the receiver operating characteristic curve was 0.82 (95% confidence interval = 0.63-1.00, p = 0.01), with a cut-off value of 5210. Conclusions In this study, 43% (9/21) of the patients with moderate/severe PVL after self-expanding TAVR had an improvement of ≥ 1 grade within 1 year, and a low degree of AVC was predictive of this improvement.
Collapse
Affiliation(s)
- Tsung-Yu Ko
- Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsin-Chu
| | | | | | | | | | | | | | | | - Yih-Sharng Chen
- Department of Surgery, National Taiwan University Hospital, Taipei Taiwan
| | | |
Collapse
|
30
|
Guimarães L, Voisine P, Mohammadi S, Kalavrouzioutis D, Dumont E, Doyle D, Paradis JM, Delarochellière R, Wintzer-Wehekind J, Junquera L, del Val D, Muntané-Carol G, Freitas-Ferraz AB, Pibarot P, Dagenais F, Rodés-Cabau J. Valve Hemodynamics Following Transcatheter or Surgical Aortic Valve Replacement in Patients With Small Aortic Annulus. Am J Cardiol 2020; 125:956-963. [PMID: 31948662 DOI: 10.1016/j.amjcard.2019.12.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 12/06/2019] [Accepted: 12/12/2019] [Indexed: 01/10/2023]
Abstract
This study aimed to compare the hemodynamic performance of transcatheter and surgical aortic valves in patients with severe symptomatic aortic stenosis and small aortic annulus (SAA) and to determine the valve hemodynamics according to transcatheter valve type. Consecutive surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) patients with SAA were case-matched (1:1) on the basis of sex, body surface area, aortic annulus diameter, and left ventricular ejection fraction. A total of 357 patients in each group constituted the final study population. A second match on the basis of aortic annulus diameter and valve/annulus calcium burden was performed within the TAVR group to compare the valve performance between balloon- (n = 52) and self-expanding (n = 52) transcatheter valve systems (BEV, SEV). The echocardiograms performed at hospital discharge were used for evaluating valve hemodynamics. The mean annulus diameter of the study population was 19.2 ± 0.3 mm. The TAVR group (vs SAVR) exhibited lower mean gradient (12 ± 7 mm Hg vs 15 ± 6 mm Hg, p <0.001), larger effective orifice area (1.46 ± 0.39 cm2 vs 1.25 ± 0.37 cm2, p <0.001) and a lower rate of severe prosthesis-patient mismatch (PPM) (14% vs 24%, p = 0.001). Moderate-severe AR was present in 2.5% of the TAVR recipients versus none patient in the SAVR group. There were no differences in valve hemodynamics between balloon-expanding transcatheter valve system and self-expanding transcatheter valve system, and similar rates of severe PPM were observed in both groups (p = 0.488). In conclusion, TAVR presented superior valve hemodynamics and lower incidence of severe PPM compared with SAVR in SAA patients. Similar valve performance results were observed between transcatheter valve types.
Collapse
|
31
|
Schröder J, Almalla M, Saad M, Mezger M, Keszei A, Frick M, Lotfi S, Hoffmann R, Becker M, Altiok E. Distinct pressure half-time values by transthoracic echocardiography for grading of paravalvular regurgitation after transcatheter aortic valve replacement. Sci Rep 2020; 10:2549. [PMID: 32054935 PMCID: PMC7018957 DOI: 10.1038/s41598-020-59211-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Accepted: 01/23/2020] [Indexed: 11/30/2022] Open
Abstract
Postprocedural aortic regurgitation (AR) has negative impact on patient outcome after transcatheter aortic valve replacement (TAVR). Standard assessment of AR severity by echocardiography is hampered after TAVR. Measurement of pressure half-time (PHT) by echocardiography is not limited in these patients but it may be affected by concomitant left ventricular hypertrophy (LVH). This study sought to evaluate distinct cut-off values of PHT differentiating between patients without and with more than mild LVH for grading of AR after TAVR with cardiac magnetic resonance (CMR) as the reference method for comparison. 71 patients (age 81 ± 6 years) with severe aortic stenosis undergoing TAVR were included into the study. Transthoracic echocardiography (TTE) and CMR were performed after TAVR. Left ventricular mass index was calculated by TTE. PHT was measured by continuous-wave Doppler echocardiography of aortic regurgitation jet. In 18 patients (25%) PHT could not be obtained due to no or very faint Doppler signal. Aortic regurgitant volume and regurgitant fraction were calculated by CMR by flow analysis of the ascending aorta. In 14 of 53 patients (26%) AR after TAVR was moderate or severe as categorized by CMR analysis. More than mild LVH was present in 27 of 53 patients (51%). PHT correlated inversely less to regurgitant fraction by CMR analysis in patients with LVH (r = −0.293; p = 0.138) than in patients without LVH (r = −0.455; p = 0.020). In patients without relevant LVH accuracy of PHT to predict moderate or severe paravalvular regurgitation AUC was 0.813 using a cut-off value of 347 ms and AUC was 0.729 in patients with more than mild LVH using a cut-off value of 420 ms. Analysis of PHT by TTE with distinct cut-off values for patients without and with more than mild LVH allows detection of moderate or severe AR after TAVR as defined by CMR. In none of the patients in which PHT could not be measured AR was categorized as more than trace by CMR analysis.
Collapse
Affiliation(s)
- Joerg Schröder
- Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany
| | - Mohammad Almalla
- Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany
| | - Mohammed Saad
- Department of Medicine - Cardiology, Angiology, Intensive Care Medicine, University Hospital Lübeck, Lübeck, Germany
| | - Matthias Mezger
- Department of Medicine - Cardiology, Angiology, Intensive Care Medicine, University Hospital Lübeck, Lübeck, Germany
| | - Andras Keszei
- Department of Medical Informatics, University Hospital RWTH Aachen, Aachen, Germany
| | - Michael Frick
- Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany
| | - Shahram Lotfi
- Department of Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - Rainer Hoffmann
- Department of Cardiology, St. Bonifatius Hospital, Lingen, Germany
| | - Michael Becker
- Department of Cardiology, Nephrology and Internal Intensive Care Medicine, Rhein-Maas Klinikum, Wuerselen, Germany
| | - Ertunc Altiok
- Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
| |
Collapse
|
32
|
Goel H, Kumar A, Garg N, Mills JD. Men are from mars, women are from venus: Factors responsible for gender differences in outcomes after surgical and trans-catheter aortic valve replacement. Trends Cardiovasc Med 2019; 31:34-46. [PMID: 31902553 DOI: 10.1016/j.tcm.2019.11.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 11/21/2019] [Accepted: 11/23/2019] [Indexed: 01/09/2023]
Abstract
Females suffer higher operative (30-day) mortality than males after surgical aortic valve replacement (SAVR). In contrast, outcomes after trans-catheter aortic valve replacement (TAVR) seem to favor females, both in terms of procedural mortality, and more prominently, medium to long-term survival. With an ever-greater number of TAVR procedures being performed, an understanding of factors responsible for gender differences in outcomes after the two AVR modalities is critical for better patient selection. Current evidence suggests that this gender difference in outcomes after SAVR and TAVR stems from differences in baseline risk profiles, as well as inherent anatomic/physiological differences between genders. This review attempts to examine these clinical and physiological factors, with a goal of guiding better patient selection for each AVR modality, and to highlight areas that beg further investigation.
Collapse
Affiliation(s)
- Harsh Goel
- Department of Medicine, St. Luke's University Hospital, Bethlehem, PA, United States; Lewis Katz School of Medicine, Temple University, Philadelphia, PA, United States.
| | - Ashish Kumar
- Department of Medicine, Wellspan York Hospital, York, PA, United States
| | - Nadish Garg
- Department of Medicine, St Barnabas Medical Center, Livingston, NJ, United States
| | - James D Mills
- Department of Medicine, Division of Cardiovascular Medicine, West Virginia University Heart and Vascular Institute, Morgantown, WV, United States
| |
Collapse
|
33
|
Ng VG, Hahn RT, Nazif TM. Planning for Success: Pre-procedural Evaluation for Transcatheter Aortic Valve Replacement. Cardiol Clin 2019; 38:103-113. [PMID: 31753169 DOI: 10.1016/j.ccl.2019.09.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Vivian G Ng
- Division of Cardiology, Columbia University Medical Center, NewYork-Presbyterian Hospital, 177 Fort Washington Avenue, 5th Floor, Room 5C-501, New York, NY 10032, USA
| | - Rebecca T Hahn
- Division of Cardiology, Columbia University Medical Center, NewYork-Presbyterian Hospital, 177 Fort Washington Avenue, 5th Floor, Room 5C-501, New York, NY 10032, USA
| | - Tamim M Nazif
- Division of Cardiology, Columbia University Medical Center, NewYork-Presbyterian Hospital, 177 Fort Washington Avenue, 5th Floor, Room 5C-501, New York, NY 10032, USA.
| |
Collapse
|
34
|
Maia J, Ladeiras-Lopes R, Guerreiro C, Carvalho M, Fontes-Carvalho R, Braga P, Sampaio F. Accuracy of three-dimensional echocardiography in candidates for transcatheter aortic valve replacement. Int J Cardiovasc Imaging 2019; 36:291-298. [PMID: 31659601 DOI: 10.1007/s10554-019-01716-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 10/15/2019] [Indexed: 02/06/2023]
Abstract
The correct determination of aortic annulus dimensions is a crucial step to avoid complications in Transcatheter Aortic Valve Replacement (TAVR). Currently, the gold standard method for the evaluation of the aortic annulus is Multidetector Computed Tomography (MDCT), which is limited by the risk of contrast-induced nephropathy. Three-dimensional transesophageal echocardiography automated software (3DTEEa) have been used as an alternative in patients with contra-indications to MDCT. We aimed to evaluate the accuracy of 3DTEEa-derived aortic annulus dimensions; to assess the influence of calcification in the agreement between 3DTEEa and MDCT; and to determine reclassification in prosthesis size choice if 3DTEEa was the only imaging method. One hundred and seven consecutive patients referred for TAVR were studied. Aortic annulus dimensions were determined using MDCT and 3DTEE manual (3DTEEm) and automated measurements. Valve calcification was assessed with MDCT. Limits of agreement (LOA) were narrower for 3DTEEa (minimum diameter: mean bias 0.60; LOA - 2.94 to 4.14; maximum diameter: mean bias 0.20; LOA - 3.82 to 4.22) as compared to 3DTEEm (minimum diameter: mean bias 0.22; LOA - 3.84 to 4.28; maximum diameter: mean bias - 1.25; LOA - 6.37; 3.86). Compared to MDCT, 3DTEEa overestimated while 3DTEEm underestimated most parameters. No differences were found in average bias between methods according to quartiles of valve calcification. Most patients would have received the same size valve (63.9%) if 3DTEEa was the only available method. Measurement of aortic annulus dimensions using a 3DTEE automatic software is feasible and not influenced by valve calcification. It may be an alternative for patients who cannot undergo MDCT.
Collapse
Affiliation(s)
- João Maia
- Faculty of Medicine, University of Porto, Porto, Portugal
| | - Ricardo Ladeiras-Lopes
- Faculty of Medicine, University of Porto, Porto, Portugal.,Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal
| | - Cláudio Guerreiro
- Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal
| | - Mónica Carvalho
- Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal
| | - Ricardo Fontes-Carvalho
- Faculty of Medicine, University of Porto, Porto, Portugal.,Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal
| | - Pedro Braga
- Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal
| | - Francisco Sampaio
- Faculty of Medicine, University of Porto, Porto, Portugal. .,Cardiology Department, Centro Hospitalar de Gaia/Espinho, Rua Conceição Fernandes, 4430-502, Vila Nova de Gaia, Portugal.
| |
Collapse
|
35
|
Vollenbroich R, Wenaweser P, Macht A, Stortecky S, Praz F, Rothenbühler M, Roost E, Hunziker L, Räber L, Windecker S, Pilgrim T. Long-term outcomes with balloon-expandable and self-expandable prostheses in patients undergoing transfemoral transcatheter aortic valve implantation for severe aortic stenosis. Int J Cardiol 2019; 290:45-51. [DOI: 10.1016/j.ijcard.2019.03.050] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 03/09/2019] [Accepted: 03/24/2019] [Indexed: 01/05/2023]
|
36
|
Aortic root sizing for transcatheter aortic valve implantation using a shape model parameterisation. Med Biol Eng Comput 2019; 57:2081-2092. [PMID: 31353427 DOI: 10.1007/s11517-019-01996-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
During a transcatheter aortic valve implantation, an axisymmetric implant is placed in an irregularly shaped aortic root. Implanting an incorrect size can cause complications such as leakage of blood alongside or through the implant. The aim of this study was to construct a method that determines the optimal size of the implant based on the three-dimensional shape of the aortic root. Based on the pre-interventional computed tomography scan of 89 patients, a statistical shape model of their aortic root was constructed. The weights associated with the principal components and the volume of calcification in the aortic valve were used as parameters in a classification algorithm. The classification algorithm was trained using the patients with no or mild leakage after their intervention. Subsequently, the algorithms were applied to the patients with moderate to severe leakage. Cross validation showed that a random forest classifier assigned the same size in 65 ± 7% of the training cases, while 57 ± 8% of the patients with moderate to severe leakage were assigned a different size. This initial study showed that this semi-automatic method has the potential to correctly assign an implant size. Further research is required to assess whether the different size implants would improve the outcome of those patients.
Collapse
|
37
|
Grant JK, Braghiroli J, Panakos A, De Marchena E. Balloon aortic valvuloplasty: Treatment of rapid deployment aortic valve replacement complicated by a paravalvular leak. J Card Surg 2019; 34:738-741. [PMID: 31212381 DOI: 10.1111/jocs.14096] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 05/15/2019] [Indexed: 11/28/2022]
Abstract
The Edwards Intuity Elite valve system was designed to facilitate minimally invasive surgery and streamline complex aortic valve replacements and has since gained more popularity. Despite the superior results shown with rapid deployment aortic valve replacement (RDAVR) utilizing this valve system, paravalvular leaks (PVL), as a complication, remains a concern. Currently, there is no universally agreed single treatment option. A 53-year-old male with a history of well-controlled diabetes mellitus and hypertension presented to the emergency room with a 1-month history of angina, syncope on exertion and dyspnea. On further workup, he was found to have severe aortic stenosis in the setting of a bicuspid aortic valve, with non-obstructive coronary artery disease. He proceeded to urgent RDAVR with a 23 mm Edwards Intuity Valve. Six months post-RDAVR he re-presented with dyspnea on exertion and near syncopal episodes. Postoperative transthoracic and transesophageal echocardiography revealed moderate to severe PVL posterior to the prosthetic aortic valve. Balloon valvuloplasty with a 25 mm True Balloon was performed. Resolution of the PVL was confirmed postprocedure both by angiography and echocardiography. The patient was followed for 1 year and remained symptom-free with evidence of mild PVL on surveillance echocardiography. In conclusion, multiple treatment options for RDAVR complicated by PVL exist; however mid to long-term outcome data are lacking. We presented one such case successfully treated with balloon aortic valvuloplasty.
Collapse
Affiliation(s)
- Jelani K Grant
- Department of Medicine, University of Miami/Jackson Memorial Hospital, Miami, Florida
| | - Joao Braghiroli
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| | - Andrew Panakos
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| | - Eduardo De Marchena
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| |
Collapse
|
38
|
Stundl A, Lucht H, Shamekhi J, Weber M, Sedaghat A, Mellert F, Grube E, Nickenig G, Werner N, Sinning JM. Early versus newer generation transcatheter heart valves for transcatheter aortic valve implantation: Echocardiographic and hemodynamic evaluation of an all-comers study cohort using the dimensionless aortic regurgitation index (AR-index). PLoS One 2019; 14:e0217544. [PMID: 31150455 PMCID: PMC6544262 DOI: 10.1371/journal.pone.0217544] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 05/14/2019] [Indexed: 12/31/2022] Open
Abstract
Aims More than mild paravalvular aortic regurgitation (pAR) negatively impacts prognosis after transcatheter aortic valve implantation (TAVI). “Newer generation” transcatheter heart valves (THVs) including Direct Flow Medical, Medtronic Evolut R, Boston Lotus, and Edwards SAPIEN 3 valve system promise to improve outcome by reducing the rate of TAVI-related issues such as pAR. Aim was to evaluate and compare the hemodynamic performance with AR index of “early” vs. “newer generation” THVs and its impact on outcome. Methods and results In 805 patients undergoing TAVI, the degree of pAR was assessed using imaging modalities (angiography, echocardiography) and hemodynamic measurements (aortic regurgitation index, ARI ratio). Severity of pAR and outcome were assessed according to the VARC-2 criteria. 805 patients underwent TAVI with use of the CoreValve (n = 400), SAPIEN XT (n = 48), Direct Flow Medical (n = 38), Evolut R (n = 114), Lotus (n = 104), or SAPIEN 3 (n = 101) prosthesis. TTE post TAVI revealed that a total of 7.3% of the patients showed moderate/severe pAR. The occurrence of greater than mild pAR occurred less frequently in patients treated with “newer generation” THVs (p<0.001): CoreValve (11.3%), SAPIEN XT (12.5%), Direct Flow Medical (5.3%), Evolut R (5.3%), Lotus (0.0%), and SAPIEN 3 (0.0%). The AR index was significantly higher (p<0.001) in patients receiving “newer generation” prostheses compared to those in whom “earlier generation” THVs were used. However, the ARI was only predictive of cumulative all-cause mortality at 1 and 3 years in “early generation”, but not in “newer generation” THVs. In the overall cohort, 30-day and 1-year mortality was 4.8% and 20.1%, respectively. In patients treated with “newer generation” devices, the respective mortality rates remained substantially below those of patients treated with “earlier generation” THVs (30-day mortality: 2.5% vs. 6.7%, p< 0.001; 1-year mortality: 11.2% vs. 27.2%, p<0.001). Conclusion TAVI with use of “newer generation” THVs showed significantly reduced pAR and improved outcomes compared to “early generation” devices that could at least in part be explained by more favorable hemodynamics
Collapse
Affiliation(s)
- Anja Stundl
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Hannah Lucht
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Jasmin Shamekhi
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Marcel Weber
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Alexander Sedaghat
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Fritz Mellert
- Department of Cardiothoracic Surgery, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Eberhard Grube
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Georg Nickenig
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Nikos Werner
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Jan-Malte Sinning
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
- * E-mail:
| |
Collapse
|
39
|
Kowalewski M, Gozdek M, Raffa GM, Słomka A, Zieliński K, Kubica J, Anisimowicz L, Kowalewski J, Landes U, Kornowski R, Lorusso R, Suwalski P. Transcathether aortic valve implantation with the new repositionable self-expandable Medtronic Evolut R vs. CoreValve system: evidence on the benefit of a meta-analytical approach. J Cardiovasc Med (Hagerstown) 2019; 20:226-236. [PMID: 30829877 DOI: 10.2459/jcm.0000000000000757] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
AIMS To compare transcatheter aortic valve replacement TAVR with self-expandable first-generation Medtronic CoreValve with new-generation Evolut R devices in patients with aortic stenosis. METHODS Multiple databases were screened for all available reports directly or indirectly comparing CoreValve vs Evolut R. Primary endpoint was device success. Procedural, functional and clinical outcomes were assessed as well. RESULTS Ten retrospective series including 12 294 pts. were found. Overall device success rate was 95.5% and was statistically higher in the Evolut R treated patients as compared with CoreValve: 96.6 vs. 94.8%, respectively; RR (risk ratio) 95%CIs (confidence intervals): 1.02 (1.00-1.04); P = 0.01. There were no statistical differences with regard to postoperative mean aortic gradients 8.5 +/- 5.3 vs 7.9 +/- 4.6 with Evolut R and CoreValve. Evolut R valve demonstrated nearly 50% reduction of the risk for moderate-to-severe paravalvilar leak 0.55 (0.39-0.79); P = 0.001; 60% statistically significant lower risk of developing myocardial injury 0.40 (0.22-0.72); P = 0.002 and numerical reductions in the risk of acute kidney injury, vascular complications and bleeding. Together with significantly reduced risk of permanent pacemaker implantation (0.80 [0.67-0.96]; P = 0.02) the above benefits were associated with 40% reduction in the risk of 30-day all-cause mortality with Evolut R as compared to CoreValve: 0.60 (0.37-1.00); P = 0.05. CONCLUSIONS The use of new-generation Evolut R was associated with improved procedural, functional and clinical outcomes compared with the CoreValve device.
Collapse
Affiliation(s)
- Mariusz Kowalewski
- Clinical Department of Cardiac Surgery, Central Clinical Hospital of the Ministry of Interior in Warsaw, Warsaw.,Cardiothoracic Research Centre, Innovative Medical Forum, Bydgoszcz, Poland.,Cardio-Thoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Mirosław Gozdek
- Cardiothoracic Research Centre, Innovative Medical Forum, Bydgoszcz, Poland.,Department of Cardiology and Internal Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
| | - Giuseppe Maria Raffa
- Cardio-Thoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre, Maastricht, The Netherlands.,Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per I Trapianti e Terapie ad alta specializzazione), Palermo, Italy
| | - Artur Słomka
- Chair and Department of Pathophysiology, Collegium Medicum UMK in Bydgoszcz, Bydgoszcz
| | | | - Jacek Kubica
- Department of Cardiology and Internal Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
| | - Lech Anisimowicz
- Department of Cardiac Surgery, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz
| | - Janusz Kowalewski
- Lung Cancer and Thoracic Surgery Department, Collegium Medicum, Nicolaus Copernicus University, Toruń, Poland
| | - Uri Landes
- Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel
| | - Ran Kornowski
- Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel
| | - Roberto Lorusso
- Cardio-Thoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Piotr Suwalski
- Clinical Department of Cardiac Surgery, Central Clinical Hospital of the Ministry of Interior in Warsaw, Warsaw.,Department of Cardiac Surgery, Centre of Postgraduate Medical Education, Warsaw, Poland
| |
Collapse
|
40
|
Chakravarty T, Jilaihawi H, Doctor N, Fontana G, Forrester JS, Cheng W, Makkar R. Complications after Transfemoral Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prosthesis: The Importance of Preventative Measures and Contingency Planning. Catheter Cardiovasc Interv 2019; 91:E29-E42. [PMID: 23436313 DOI: 10.1002/ccd.24888] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Revised: 01/11/2013] [Accepted: 02/17/2013] [Indexed: 12/19/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) with balloon-expandable Edwards-SAPIEN valve was superior to standard therapy in inoperable patients and noninferior to surgical aortic valve replacement in high surgical-risk, but operable patients, with severe symptomatic aortic stenosis in the randomized controlled PARTNER trial. Since the first case of TAVR with a balloon-expandable valve in 2002, several groups have reported their experience with balloon-expandable valves with high-procedural success. In the United States, the balloon-expandable Edwards-SAPIEN valve is the only transcatheter heart valve approved by the FDA for commercial use. Moreover, this is only in high-risk inoperable patients. Despite increasing experience with the TAVR procedure, it can be associated with complications, which can be technically challenging, even for an experienced operator. Complications associated with TAVR include vascular complications, valve malpositioning, regurgitation, embolization, coronary compromise, conduction abnormalities, stroke/transient ischemic attack, acute kidney injury, cardiac tamponade, and hemodynamic collapse. A thorough understanding of the procedure is essential for pre-emptive planning for procedural complications and early identification and management of complications are necessary for procedural success. We hereby review our experience of transfemoral TAVR with balloon-expandable valves, offer practical tips to maximize the likelihood of procedural success, describe pre-emptive strategies to prevent peri-procedural complications and bailout measures to manage them, should they occur. © 2018 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
| | | | - Niraj Doctor
- Cedars-Sinai Heart Institute, Los Angeles, California
| | | | | | - Wen Cheng
- Cedars-Sinai Heart Institute, Los Angeles, California
| | - Raj Makkar
- Cedars-Sinai Heart Institute, Los Angeles, California
| |
Collapse
|
41
|
Aortic annulus measurement with computed tomography angiography reduces aortic regurgitation after transfemoral aortic valve replacement compared to 3-D echocardiography: a single-centre experience. Clin Res Cardiol 2019; 108:1266-1275. [PMID: 30972479 DOI: 10.1007/s00392-019-01462-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Accepted: 03/19/2019] [Indexed: 01/10/2023]
Abstract
BACKGROUND Accurate assessment of the aortic annulus is crucial for successful transcatheter aortic valve replacement (TAVR), in particular to prevent paravalvular regurgitation (PVR). We compared aortic annular sizing using multidetector computed tomography (MDCT) and three-dimensional transoesophageal echocardiography (3-D TEE) to determine the predictive value of MDCT. METHODS AND RESULTS All patients admitted for transfemoral TAVR [n = 227; 48.9% balloon expandable (Edwards Sapien 3); 51.1% self-expandable (Core Valve, Evolut R)] at our institution from January 2015 until December 2016 were analysed retrospectively. Aortic annular parameters were obtained either by MDCT or 3-D TEE. Additionally, we included a cohort of patients (n = 27) assessed by both MDCT and 3D TEE between October 2017 and April 2018 to enable intra-individual comparison of the two methods. Indications for TAVR were severe degenerative aortic stenosis (AS; 94.7%) or re-stenosis after surgical AVR (5.3%). 74.4% were classified as high-gradient AS. The mean age was 80 (37-94) years and 75.8% presented with NYHA III/IV. STS risk of mortality was intermediate (3.5 ± 2.3). MDCT and 3-D TEE were performed in 116 and 111 patients for aortic annulus sizing, respectively. Significantly larger implants were chosen in the CT group irrespective of prosthesis type or post-dilatation. Follow-up (median at 79 days) revealed significantly less PVR in the MDCT compared to 3-D TEE group (absence of PVR in 59.3% and 40.7%, p = 0.016), without differences in mortality. Patients without PVR or mild PVR had a better clinical performance according to NYHA class (p = 0.016). CONCLUSION MDCT is superior to 3-D TEE in terms of sizing accuracy and clinical outcomes. Reduction of PVR after TAVR with MDCT is likely due to valve annulus undersizing by TEE.
Collapse
|
42
|
Egron S, Fujita B, Gullón L, Pott D, Schmitz-Rode T, Ensminger S, Steinseifer U. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves. ASAIO J 2019; 64:536-543. [PMID: 28885378 DOI: 10.1097/mat.0000000000000659] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The goal is to inform in depth on transcatheter aortic valve replacement (TAVR) prosthesis mechanical behavior, depending on frame type, design, and size, and how it crucially impacts the oversizing issue in clinical use, and ultimately the procedure outcome. Transcatheter aortic valve replacement is an established therapy for high-risk patients suffering from aortic stenosis, and the indication for TAVR is progressively expanding to intermediate-risk patients. Choosing the optimal oversizing degree is crucial to safely anchor the TAVR valve-which involves limiting the risks for embolism, aortic regurgitation, conductance disturbance, or annulus rupture-and to increase the valve prosthesis performance. The radial force (RF) profiles of five TAVR prostheses were measured in vitro: the CoreValve 23 and 26 (Medtronic, Minneapolis, MN), the Acurate neo S (Symetis, Écublens, Vaud, Switzerland), and the SAPIEN XT 23 and 26 (Edwards Lifesciences, Irvine, CA). Measurements were run with the RX Machine equipment (Machine Solutions Inc., Flagstaff, AZ), which is used in ISO standard tests for intravascular stents. Test protocols were adapted for TAVR prostheses. With the prostheses RF profiles' results, mechanical behavior differences could be described and discussed in terms of oversizing strategy and clinical impact for all five valves. Besides, crossing the prostheses' RF profiles with their recommended size windows made the assessment of borderline size cases possible and helped analyze the risks when accurate measurement of patient aortic annulus proves difficult. The prostheses' RF profiles bring new support in clinical decision-making for valve type and size in patients.
Collapse
Affiliation(s)
- Sandrine Egron
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Buntaro Fujita
- Department for Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr University Bochum, Bad Oeynhausen, Germany
| | - Lucía Gullón
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Désirée Pott
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Stephan Ensminger
- Department for Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr University Bochum, Bad Oeynhausen, Germany
| | - Ulrich Steinseifer
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
43
|
Aalaei-Andabili SH, Bavry AA. Left Ventricular Diastolic Dysfunction and Transcatheter Aortic Valve Replacement Outcomes: A Review. Cardiol Ther 2019; 8:21-28. [PMID: 30847743 PMCID: PMC6525224 DOI: 10.1007/s40119-019-0134-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Indexed: 12/23/2022] Open
Abstract
Aortic stenosis (AS) is the most common valvular disease that can lead to increased afterload, left ventricular (LV) remodeling, and myocardial fibrosis. We reviewed the literature addressing the impact of transcatheter aortic valve replacement (TAVR) on LV remodeling and patients' outcomes by elimination of AS-related high afterload. TAVR reduces afterload and improves LV remodeling recovery. However, myocardial fibrosis may not completely reverse after the TAVR. The LV diastolic dysfunction (LVDD) induced by AS is an independent predictor of post-TAVR mortality, and mortality increases with severity of LVDD. The impact of diastolic dysfunction on patient outcomes emerges at 30 days but continues to persist during mid-term follow-up. Based on severity of the baseline LVDD, some patients may tolerate post-TAVR aortic regurgitation (AR), but even minimal post-TAVR AR in patients with severe baseline LVDD can have an additive negative impact on survival. It is crucial to consider TAVR prior to development of advanced LVDD. Appropriate device selection and deployment technique are important in improvement of TAVR outcomes via elimination of AR.
Collapse
Affiliation(s)
| | - Anthony A Bavry
- Department of Medicine, University of Florida, Gainesville, FL, USA.
- North Florida/South Georgia Veterans Health System, Gainesville, FL, USA.
| |
Collapse
|
44
|
|
45
|
Pierce EL, Sadri V, Ncho B, Kohli K, Shah S, Yoganathan AP. Novel In Vitro Test Systems and Insights for Transcatheter Mitral Valve Design, Part I: Paravalvular Leakage. Ann Biomed Eng 2019; 47:381-391. [PMID: 30341735 PMCID: PMC6344268 DOI: 10.1007/s10439-018-02154-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Accepted: 10/10/2018] [Indexed: 11/26/2022]
Abstract
While transcatheter mitral valve (TMV) replacement technology has great clinical potential for surgically inoperable patients suffering from mitral regurgitation, no TMV has yet achieved regulatory approval. The diversity of devices currently under development reflects a lack of consensus regarding optimal design approaches. In Part I of this two-part study, a test system was developed for the quantification of paravalvular leakage (PVL) following deployment of a TMV or TMV-like device in pressurized, explanted porcine hearts (N = 7). Using this system, PVL rate was investigated as a function of steady trans-mitral pressure (ΔP), TMV shape, and TMV-annular oversizing, using a series of "mock TMV plug" devices. Across all devices, PVL was found to approximately trend with the square of ΔP. PVL rates were approximately 0-15 mL/s under hypotensive pressure, 10-40 mL/s under normotension, and 30-85 mL/s under severe hypertension. D-shaped devices significantly reduced PVL vs. circular devices; however, this effect was diminished upon oversizing to the annulus by 6 mm inter-trigonal distance. In conclusion, this steady pressure, in vitro test system was effective to compare PVL performance across TMV-like designs. PVL exhibited complex dynamics in terms of its response to transvalvular pressure and TMV profile.
Collapse
Affiliation(s)
- Eric L Pierce
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA
| | - Vahid Sadri
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA
| | - Beatrice Ncho
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA
| | - Keshav Kohli
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA
| | - Siddhi Shah
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
| |
Collapse
|
46
|
Kamioka N, Arita T, Hanyu M, Hayashi M, Watanabe S, Miura S, Isotani A, Arai Y, Kakumoto S, Ando K, Shirai S. Valve Hemodynamics and Clinical Outcomes After Transcatheter Aortic Valve Replacement for a Small Aortic Annulus. Int Heart J 2019; 60:86-92. [DOI: 10.1536/ihj.17-656] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Affiliation(s)
| | | | - Michiya Hanyu
- Department of Cardiovascular Surgery, Kokura Memorial Hospital
| | | | - Shun Watanabe
- Department of Cardiovascular Surgery, Kokura Memorial Hospital
| | - Shiro Miura
- Department of Cardiology, Kokura Memorial Hospital
| | | | - Yoshio Arai
- Department of Cardiovascular Surgery, Kokura Memorial Hospital
| | | | - Kenji Ando
- Department of Cardiology, Kokura Memorial Hospital
| | | |
Collapse
|
47
|
Indolfi C, Bartorelli AL, Berti S, Golino P, Esposito G, Musumeci G, Petronio S, Tamburino C, Tarantini G, Ussia G, Vassanelli C, Spaccarotella C, Violini R, Mercuro G, Romeo F. Updated clinical indications for transcatheter aortic valve implantation in patients with severe aortic stenosis: expert opinion of the Italian Society of Cardiology and GISE. J Cardiovasc Med (Hagerstown) 2018; 19:197-210. [PMID: 29578921 DOI: 10.2459/jcm.0000000000000636] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
: The introduction of percutaneous treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI) remains one of the greatest achievements of interventional cardiology. In fact, TAVI emerged as a better option than either medical therapy or balloon aortic valvuloplasty for patients who cannot undergo surgical aortic valve replacement (SAVR) or are at high surgical risk. Recently, increased operator experience and improved device systems have led to a worldwide trend toward the extension of TAVI to low-risk or intermediate-risk patients. In this expert opinion paper, we first discuss the basic pathophysiology of aortic stenosis in different settings then the key results of recent clinical investigations on TAVI in intermediate-risk aortic stenosis patients are summarized. Particular emphasis is placed on the results of the nordic aortic valve intervention, placement of aortic transcatheter valves (PARTNER) 2 and Surgical Replacement and Transcatheter Aortic Valve Implantation Randomized trials. The PARTNER 2 was the first large randomized trial that evaluated the outcome of TAVI in patients at intermediate risk. The PARTNER 2 data demonstrated that TAVI is a feasible and reasonable alternative to surgery in intermediate-risk patients (Society of Thoracic Surgeons 4-8%), especially if they are elderly or frail. There was a significant interaction between TAVI approach and mortality, with transfemoral TAVI showing superiority over SAVR. Moreover, we examine the complementary results of the recently concluded Surgical Replacement and Transcatheter Aortic Valve Implantation trial. This prospective randomized trial demonstrated that TAVI is comparable with surgery (primary end point 12.6% in the TAVI group vs. 14.0% in the SAVR group) in severe aortic stenosis patients deemed to be at intermediate risk. We review the most relevant clinical evidence deriving from nonrandomized studies and meta-analyses. Altogether, clinical outcome available data suggest that TAVI with a newer generation device might be the preferred treatment option in this patient subgroup. Finally, the differences between the latest European and American Guidelines on TAVI were reported and discussed. The conclusion of this expert opinion article is that TAVI, if feasible, is the treatment of choice in patients with prohibitive or high surgical risk and may lead to similar or lower early and midterm mortality rates compared with SAVR in intermediate-risk patients with severe aortic stenosis.
Collapse
Affiliation(s)
- Ciro Indolfi
- Cattedra di Cardiologia, Università degli Studi Magna Graecia, Catanzaro, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Chow SC, Wan IY, Wong RH, Underwood MJ. Transcatheter aortic valve implantation: The evolving role of surgeons and challenges ahead. SURGICAL PRACTICE 2018. [DOI: 10.1111/1744-1633.12342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Simon C.Y. Chow
- Department of Surgery; The Chinese University of Hong Kong, Prince of Wales Hospital; Hong Kong
| | - Innes Y.P. Wan
- Department of Surgery; The Chinese University of Hong Kong, Prince of Wales Hospital; Hong Kong
| | - Randolph H.L. Wong
- Department of Surgery; The Chinese University of Hong Kong, Prince of Wales Hospital; Hong Kong
| | - Malcolm J. Underwood
- Department of Surgery; The Chinese University of Hong Kong, Prince of Wales Hospital; Hong Kong
| |
Collapse
|
49
|
3D-TEE for Measurement of the Aortic Annulus: a Review of the Literature and Step-By-Step Approach to an Essential Skill. CURRENT CARDIOVASCULAR IMAGING REPORTS 2018. [DOI: 10.1007/s12410-018-9465-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
50
|
Ong G, Annabi MS, Clavel MA, Guzzetti E, Salaun E, Toubal O, Dahou A, Pibarot P. Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement: Is the Problem Solved? Interv Cardiol Clin 2018; 7:445-458. [PMID: 30274611 DOI: 10.1016/j.iccl.2018.06.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Paravalvular regurgitation is a frequent complication after transcatheter aortic valve replacement and its association with worse outcomes depends on the degree of its severity. Despite substantial improvement in transcatheter heart valve design, sizing and implantation technique, moderate or severe paravalvular regurgitation still occurs in 2% to 7% of patients and is associated with a more than 2-fold increase in mortality. This review provides a state-of-the-art approach to (i) paravalvular regurgitation prevention by optimizing patient selection, valve sizing, and positioning and (ii) the detection, quantitation and management of paravalvular regurgitation during and after valve implantation.
Collapse
Affiliation(s)
- Géraldine Ong
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Mohammed-Salah Annabi
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Marie-Annick Clavel
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Ezequiel Guzzetti
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Erwan Salaun
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Oumhani Toubal
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Abdellaziz Dahou
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada
| | - Philippe Pibarot
- Department of Medicine, Laval University, Institut de cardiologie et de pneumologie de Québec/ Laval Heart and Lung Institute, 2725 chemin Sainte-Foy, Quebec City, Quebec G1V-4G5, Canada.
| |
Collapse
|