1
|
Yoon HY, Byun YS, Kim HS, Chung SH. Causes and outcomes of implantable collamer lens explantation in patients with corneal endothelial cell loss. J Cataract Refract Surg 2024; 50:453-459. [PMID: 38270485 DOI: 10.1097/j.jcrs.0000000000001406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 01/13/2024] [Indexed: 01/26/2024]
Abstract
PURPOSE To investigate the correlated factors of corneal endothelial cell density (ECD) loss and ECD change in implantable collamer lens (ICL) explantation patients. SETTING Seoul St. Mary's Hospital, Seoul, South Korea. DESIGN Retrospective analysis. METHODS The study cohort consisted of 93 eyes from 50 patients who underwent ICL explantation. Correlation analysis was performed to assess the ocular parameters associated with ECD loss, while percentage of ECD change (ΔECD%) was monitored up to 6 months postoperatively. Receiver operating characteristic (ROC) curve was used to set cutoff values of ocular parameters to prevent ECD loss after explantation. RESULTS In multiple regression analysis, high vaulting, high vaulting/anterior chamber depth (ACD), low anterior chamber angle (ACA), and high iris pigmentations are the significant factors of ECD loss. At postoperative 6 months, 14 eyes (15.1%) had decrease (10.5% loss), 47 eyes (51.0%) were stationary, and 32 eyes (34.4%) had increase (12.7% gain) of ECD. The ROC curve analysis showed that vaulting had the highest area under the curve (AUC = 0.822), followed by vaulting/ACD (AUC = 0.821), ECD (AUC = 0.753), and ACA (AUC = 0.723) (all P < .01). Preoperative ECD showed a sensitivity of 77.6% and specificity of 86.7% in preventing ECD loss after explantation, with a cutoff value of 1722 cells/mm 2 , as determined by ROC curve analysis. CONCLUSIONS Our study demonstrated that high vaulting is a significant factor in ECD loss among ICL-inserted patients. To prevent continuous ECD loss in ICL patients, close monitoring of ECD and making appropriate decisions regarding explantation may be necessary.
Collapse
Affiliation(s)
- Hye Yeon Yoon
- From the Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | | | | | | |
Collapse
|
2
|
Gong D, Deng S, Dang K, Yan Z, Wang J. Causes and management strategies for elevated intraocular pressure after implantable collamer lens implantation. Front Med (Lausanne) 2024; 11:1351272. [PMID: 38384405 PMCID: PMC10879591 DOI: 10.3389/fmed.2024.1351272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/25/2024] [Indexed: 02/23/2024] Open
Abstract
With the widespread application of Implantable Collamer Lens (ICL) implantation surgery in the field of myopia correction, a comprehensive understanding of its potential complications, especially those related to intraocular pressure (IOP), becomes crucial. This article systematically reviews various complications that may lead to IOP elevation after ICL surgery. Firstly, common complications after ICL surgery, including residual viscoelastic, steroid response, and excessive vault of the ICL, are detailed, emphasizing their potential impact on intraocular pressure. Regarding residual viscoelastic, we delve into its direct relationship with postoperative elevated IOP and possible preventive measures. For steroid response, we stress the importance of timely adjustment of steroid therapy and monitoring intraocular pressure. Additionally, excessive vault of the ICL is considered a significant potential issue, and we elaborate on its mechanism and possible management methods. In further discussion, we focus on relatively rare complications such as Toxic Anterior Segment Syndrome (TASS), Urrets-Zavalia Syndrome (UZS), Pigment Dispersion Syndrome (PDS), and malignant glaucoma. For these relatively rare complications, this review thoroughly explores their potential mechanisms, emphasizes the importance of prevention, and provides guidance for early diagnosis and treatment. This is a comprehensible review that aims to offer eye care professionals a comprehensive understanding and effective management guidance for complications of elevated IOP after ICL surgery, ultimately providing optimal care for patients' visual health.
Collapse
Affiliation(s)
- Di Gong
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Simin Deng
- The 2nd Clinical Medical College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Kuanrong Dang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Zonghui Yan
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Jiantao Wang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| |
Collapse
|
3
|
Sánchez-Trancón A, Manito SC, Sierra OT, Baptista AM, Serra PM. Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation. Int Ophthalmol 2024; 44:15. [PMID: 38321260 DOI: 10.1007/s10792-024-02924-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 12/17/2023] [Indexed: 02/08/2024]
Abstract
PURPOSE This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. METHODS This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. RESULTS Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. CONCLUSIONS Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.
Collapse
Affiliation(s)
- Angel Sánchez-Trancón
- Ophthalmology Clinic Vista Sánchez Trancón, Room 15, Calle La Violeta, 06005, Badajoz, Spain
| | - Santiago Cerpa Manito
- Ophthalmology Clinic Vista Sánchez Trancón, Room 15, Calle La Violeta, 06005, Badajoz, Spain
| | - Oscar Torrado Sierra
- Ophthalmology Clinic Vista Sánchez Trancón, Room 15, Calle La Violeta, 06005, Badajoz, Spain
| | | | - Pedro Miguel Serra
- Ophthalmology Clinic Vista Sánchez Trancón, Room 15, Calle La Violeta, 06005, Badajoz, Spain.
| |
Collapse
|
4
|
Martínez-Plaza E, López-de la Rosa A, Ossa-Calderon C, Blázquez-Arauzo F, López-Miguel A, Maldonado MJ. Assessment of the iridocorneal angle pigmentation and structures after the implantation of EVO+ Visian Implantable Collamer Lens. Int Ophthalmol 2023; 43:4711-4718. [PMID: 37697080 DOI: 10.1007/s10792-023-02871-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 08/26/2023] [Indexed: 09/13/2023]
Abstract
PURPOSE To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, Universidad de Valladolid, Valladolid, Spain
| | - Carolina Ossa-Calderon
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Francisco Blázquez-Arauzo
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain.
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain.
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
5
|
Tan X, Liu W, Chang Y, Wu W, Yang L, Liu J. Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation. Int J Gen Med 2023; 16:2451-2459. [PMID: 37346811 PMCID: PMC10281286 DOI: 10.2147/ijgm.s384858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 06/12/2023] [Indexed: 06/23/2023] Open
Abstract
Purpose The safety and stability of implantable collamer lens (ICL) implantation are closely related to the vault. We aimed to assess clinical data from patients with similar anterior segment anatomy who received ICL of the same model placed in the same position and analyze common range and factors affecting the vault inter-eye difference. Patients and Methods A prospective study was performed, including 162 eyes of 81 patients with a bilateral ICL (V4c) implantation. Subjects were evaluated before the surgery and 1 day, 1 week, and 1 month postoperatively, and they were divided into 4 groups based on the ICL size. Bivariate correlation and multiple linear regression (stepwise) analyzed associations between vault inter-eye differences and horizontal sulcus-to-sulcus diameter, anterior chamber depth, lens thickness, ICL size, spherical equivalent, and vault. Results One month after surgery, mean vault inter-eye differences were 74.59 ± 55.59 µm. Nearly 70% of patients presented with vault inter-eye differences lower than 100 µm. The second eye vault variance of 69% was attributed to the first eye vault. Vault inter-eye differences were positively correlated with ICL spherical equivalent (regression equation: vault inter-eye differences (μm) = 139.415 + 6.295 × ICL spherical equivalent). Vaults after ICL implantation were similar in fellow eyes, with some considerable differences. The 95% confidence interval of the vault inter-eye difference was -34.4 ~ 183.6 μm. Conclusion In eyes with similar anterior segment anatomy, there is a 95% probability that the vault will vary from -34.4 μm to -183.6 μm when a similar ICL is implanted. These results can help surgeons to select an appropriate ICL size to achieve an ideal vault. The smaller the spherical equivalent, the larger the difference between the two vaults, which provides a reference for size in moderate myopia. ICL spherical equivalent affects and predicts vault inter-eye differences after ICL implantation.
Collapse
Affiliation(s)
- Xin Tan
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Wenjie Liu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Ying Chang
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Wanmin Wu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Lichun Yang
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Jiewei Liu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| |
Collapse
|
6
|
Yang G, Li K, Yao J, Chang S, He C, Lu F, Wang X, Wang Z. Automatic measurement of anterior chamber angle parameters in AS-OCT images using deep learning. BIOMEDICAL OPTICS EXPRESS 2023; 14:1378-1392. [PMID: 37078037 PMCID: PMC10110310 DOI: 10.1364/boe.481419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 02/17/2023] [Accepted: 02/19/2023] [Indexed: 05/03/2023]
Abstract
The early assessment of angle closure is of great significance for the timely diagnosis and treatment of primary angle-closure glaucoma (PACG). Anterior segment optical coherence tomography (AS-OCT) provides a fast and non-contact way to evaluate the angle close using the iris root (IR) and scleral spur (SS) information. The objective of this study was to develop a deep learning method to automatically detect IR and SS in AS-OCT for measuring anterior chamber (AC) angle parameters including angle opening distance (AOD), trabecular iris space area (TISA), trabecular iris angle (TIA), and anterior chamber angle (ACA). 3305 AS-OCT images from 362 eyes and 203 patients were collected and analyzed. Based on the recently proposed transformer-based architecture that learns to capture long-range dependencies by leveraging the self-attention mechanism, a hybrid convolutional neural network (CNN) and transformer model to encode both local and global features was developed to automatically detect IR and SS in AS-OCT images. Experiments demonstrated that our algorithm achieved a significantly better performance than state-of-the-art methods for AS-OCT and medical image analysis with a precision of 0.941, a sensitivity of 0.914, an F1 score of 0.927, and a mean absolute error (MAE) of 37.1±25.3 µm for IR, and a precision of 0.805, a sensitivity of 0.847, an F1 score of 0.826, and an MAE of 41.4±29.4 µm for SS, and a high agreement with expert human analysts for AC angle parameter measurement. We further demonstrated the application of the proposed method to evaluate the effect of cataract surgery with IOL implantation in a PACG patient and to assess the outcome of ICL implantation in a patient with high myopia with a potential risk of developing PACG. The proposed method can accurately detect IR and SS in AS-OCT images and effectively facilitate the AC angle parameter measurement for pre- and post-operative management of PACG.
Collapse
Affiliation(s)
- Guangqian Yang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Kaiwen Li
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Jinhan Yao
- Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi 030001, China
| | - Shuimiao Chang
- Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi 030001, China
| | - Chong He
- School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Fang Lu
- School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Xiaogang Wang
- Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi 030001, China
- Co-last authors
| | - Zhao Wang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
- Co-last authors
| |
Collapse
|
7
|
Zhang W, Li F, Li L, Zhang J. A quantitative study of the effect of ICL orientation selection on post-operative vault and model-assisted vault prediction. Front Neurol 2023; 14:1136579. [PMID: 36937516 PMCID: PMC10020497 DOI: 10.3389/fneur.2023.1136579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 02/14/2023] [Indexed: 03/06/2023] Open
Abstract
Background Appropriate vault height of implantable collamer lens (ICL) implantation matters for it has risks of corneal endothelial cell loss, cataract formation and intraocular pressure elevation, which could lead to irreversible damage to optic nerve. Therefore, pre-operative prediction for an ideal vault height is a hotspot. However, few data exist regarding quantitative effect of ICL orientation on vault height. This study is aimed to quantitatively investigate the effect of ICL implantation orientation on vault height, and built a machine-learning (ML)-based vault prediction model taking implantation orientation into account. Methods 473 consecutive case series treated with ICL implantation were retrospectively analyzed (408 were horizontally implanted, and 65 were vertically implanted). Multivariable logistic regression analysis was performed to determine the association between ICL orientation and achieved vault. ML was performed to develop a new vault height prediction model taking ICL orientation into account. Receiver operating characteristic curve (ROC) and net reclassification index (NRI) were obtained to assess the prediction ability. Results 95% of all the patients achieved 20/20 uncorrected distance visual acuity (UDVA) or better. No complications including cataract formation, dispersion or optic nerve injury were observed in any cases. Sex, sphere power, cylinder power, axis, ICL size and ICL orientation were all significant risk factors associated to vault height, and age was positively co-related. Of note, ICL size and ICL orientation were the top-ranking risk factors. Comparing to conventional horizontal implantation, vertical implantation could reduce the achieved vault by 81.187 μm (p < 0.001). In regarding to different ICL sizes, vertical implantation had no good to vault reduction when using ICL of 12.1 mm. However, it could reduce the vault by 59.351 μm and 160.992 μm respectively when ICL of 12.6mm and 13.2 mm were implanted (p = 0.0097 and p = 0.0124). For prediction of vault height, ML based model significantly outperformed traditional multivariable regression model. Conclusion We provide quantitative evidence that vertical implantation of ICL could effectively reduce the achieved vault height, especially when large size ICL was implanted, comparing to traditional horizontal implantation. ML is extremely applicable in development of vault prediction model.
Collapse
Affiliation(s)
- Weijie Zhang
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Fang Li
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Lin Li
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
- Lin Li
| | - Jing Zhang
- Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
- *Correspondence: Jing Zhang
| |
Collapse
|
8
|
Zhu QJ, Xing XY, Zhu MH, Ma L, Yuan Y, Song E. Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study. BMC Ophthalmol 2022; 22:463. [PMID: 36451125 PMCID: PMC9714062 DOI: 10.1186/s12886-022-02698-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 11/21/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland-Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland-Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- grid.452666.50000 0004 1762 8363Department of Ophthalmology, The Second Affiliated Hospital of Soochow University, Suzhou, China ,grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | | | - Man-Hui Zhu
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - Lie Ma
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - You Yuan
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - E. Song
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| |
Collapse
|
9
|
Liu F, Xia F, Niu L, Zhao J, Wang X, Zhou X. Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT. Transl Vis Sci Technol 2022; 11:4. [PMID: 36331273 PMCID: PMC9645365 DOI: 10.1167/tvst.11.11.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Purpose To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). Methods In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal–temporal (0°–180°), superior–inferior (90°–270°), and superior nasal–inferior temporal (80°–260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular–iris space area at 500 µm (TISA500), trabecular–iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular–iris circumference volume at 500 µm (TICV500), and the index and area of iris–trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. Results The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm2 to 12.343% ± 13.216% and 0.903 ± 1.304 mm2 (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior–nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. Conclusions Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior–nasal and superior quadrants. Translational Relevance We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.
Collapse
Affiliation(s)
- Fang Liu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Fei Xia
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
10
|
Zhang H, Gong R, Zhang X, Deng Y. Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation. Int Ophthalmol 2022; 42:3625-3641. [PMID: 35731355 PMCID: PMC9587946 DOI: 10.1007/s10792-022-02355-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/18/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To introduce a modified procedure of ICL implantation, to summarize the perioperative problems and their corresponding treatment after myopia correction with Implantable Collamer Lens (ICL), and to compare the difference of complications between the no-hole ICL and hole ICL. METHODS We searched all articles on ICL-related perioperative problems and their corresponding treatment in Scopus, Embase, PubMed and Web of Science databases for the last 22 years. RESULTS ICL implantation is safe, effective, stable and predictable in the correction of myopia, hyperopia and astigmatism, but can also cause a series of perioperative problems, including intraoperative and postoperative complications. CONCLUSION There are many kinds of complications related to ICL, but the common intraoperative and postoperative complications mainly include abnormality of arch height, abnormal position of ICL, loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma, cataract and night vision symptoms. Compared with ICL without central pore, the incidence of complications such as loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma and cataract was relatively lower in central hole ICL, while postoperative complications such as night vision symptoms were obvious.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Rui Gong
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Xiaolan Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Yingping Deng
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|
11
|
Zhu QJ, Zhu WJ, Chen WJ, Ma L, Yuan Y. A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study. BMC Ophthalmol 2022; 22:307. [PMID: 35842598 PMCID: PMC9287952 DOI: 10.1186/s12886-022-02535-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 07/13/2022] [Indexed: 11/15/2022] Open
Abstract
Background To establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model. Methods In this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data from 278 eyes from 139 subjects between May 2021 and June 2021. Each subject was measured with a Pentacam, IOLMaster 700, OPD-Scan III, and ultrasound biomicroscope. The prediction formulas were established with multiple linear regression, and intergroup correlation coefficients (ICCs) and Bland–Altman tests were used to assess the agreement between the predicted and actual STS (actual STS was measured by UBM). Results The explanatory variables relevant to the horizontal STS (STSH) were the Pentacam white-to-white diameter (WTWP; standardized partial regression coefficient [β] = 0.330; p < 0.001), the flat K value (β = -0.211; p < 0.001), and the anterior corneal diameter (ACD) (β = 0.178; p < 0.001). The corresponding multiple regression equation was : STSH (mm) = 8.061 + 0.510 × WTWP − 0.090 × Flat K value + 0.430 × ACD. The explanatory variables relevant to the vertical STS (STSV) were the WTWP (β = 0.435; p < 0.001), the steep K value (β = -0.271; p < 0.001), and the ACD (β = 0.187; p < 0.001). The corresponding multiple regression equation was : STSV (mm) = 8.540 + 0.492 × WTWP − 0.075 × Steep K value + 0.329 × ACD. The bias of the predicted to the actual STSH was − 0.021, with 95% limits of agreement (95% LoA) from − 0.499 to 0.457. The bias of the predicted to the actual STSV was 0.057, with 95% LoA from − 0.462 to 0.575. The ICC was 0.883 between the predicted and actual STSH and 0.859 between the predicted and actual STSV. Conclusions The Pentacam-measured WTW, the K value and the ACD are important for predicting the STS diameter. The prediction model has good accuracy and reliability. Trial registration Not applicable.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Wei-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Wen-Jing Chen
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Lie Ma
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - You Yuan
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China.
| |
Collapse
|
12
|
Adetunji MO, Meer E, Whitehead G, Hua P, Badami A, Addis V, Gorry T, Lehman A, Sankar PS, Miller-Ellis E, Ying GS, Cui QN. Self-identified Black Race as a Risk Factor for Intraocular Pressure Elevation and Iritis Following Prophylactic Laser Peripheral Iridotomy. J Glaucoma 2022; 31:218-223. [PMID: 35131983 PMCID: PMC8963523 DOI: 10.1097/ijg.0000000000001995] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 12/27/2021] [Indexed: 11/26/2022]
Abstract
PRCIS In primary angle closure suspects (PACS), self-identified Black race was a risk factor for intraocular pressure (IOP) elevation and iritis following laser peripheral iridotomy (LPI). Laser type was not associated with either immediate post-LPI IOP elevation or iritis in multivariate analysis. PURPOSE The aim was to determine the impact of laser type and patient characteristics on the incidence of IOP elevation and iritis after LPI in PACS. MATERIALS AND METHODS The electronic medical records of 1485 PACS (2407 eyes) who underwent either neodymium-doped yttrium-aluminum-garnet or sequential argon and neodymium-doped yttrium-aluminum-garnet LPI at the University of Pennsylvania between 2010 and 2018 were retrospectively reviewed. Average IOP within 30 days before LPI (baseline IOP), post-LPI IOP within 1 hour, laser type, laser energy, and the incidence of new iritis within 30 days following the procedure were collected. Multivariate logistic regression accounting for intereye correlation was used to assess factors associated with incidence of post-LPI IOP elevation and iritis, adjusted by age, sex, surgeon, and histories of autoimmune disease, diabetes, and hypertension. RESULTS The incidence of post-LPI IOP elevation and iritis were 9.3% (95% confidence interval: 8.1%-10.5%) and 2.6% (95% CI: 1.9%-3.2%), respectively. In multivariate analysis, self-identified Black race was a risk factor for both IOP elevation [odds ratio (OR): 2.08 compared with White; P=0.002] and iritis (OR: 5.07; P<0.001). Higher baseline IOP was associated with increased risk for post-LPI IOP elevation (OR: 1.19; P<0.001). Laser type and energy were not associated with either post-LPI IOP elevation or iritis (P>0.11 for all). CONCLUSIONS The incidence of immediate IOP elevation and iritis following prophylactic LPI was higher in Black patients independent of laser type and energy. Heightened vigilance and increased medication management before and after the procedure are suggested to help mitigate these risks.
Collapse
Affiliation(s)
| | - Elana Meer
- Department of Ophthalmology, Scheie Eye Institute
| | | | - Peiying Hua
- Department of Ophthalmology, Scheie Eye Institute
- Department of Ophthalmology, Center for Preventive Ophthalmology and Biostatistics, University of Pennsylvania Perelman School of Medicine
| | - Avni Badami
- Department of Ophthalmology, Scheie Eye Institute
| | | | | | - Amanda Lehman
- Philadelphia Veterans Affairs Medical Center, Philadelphia, PA
| | | | | | - Gui-Shuang Ying
- Department of Ophthalmology, Scheie Eye Institute
- Department of Ophthalmology, Center for Preventive Ophthalmology and Biostatistics, University of Pennsylvania Perelman School of Medicine
| | - Qi N. Cui
- Department of Ophthalmology, Scheie Eye Institute
| |
Collapse
|
13
|
Gonzalez-Lopez F, Bouza-Miguens C, Tejerina V, Druchkiv V, Mompean B, Ortega-Usobiaga J, Bilbao-Calabuig R. Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation. EYE AND VISION 2021; 8:39. [PMID: 34688308 PMCID: PMC8542318 DOI: 10.1186/s40662-021-00262-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Accepted: 10/04/2021] [Indexed: 11/29/2022]
Abstract
Purpose To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port.
Methods This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. Results Preoperative mean pupil size under photopic conditions was 3.38 ± 0.64 mm; after surgery, this increased to 3.48 ± 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 ± 0.79 mm before surgery and 5.84 ± 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 ± 0.44 mm (P = 0.078) and 0.12 ± 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 ± 177 μm under maximum miosis and 506 ± 190 μm under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). Conclusion Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00262-2.
Collapse
Affiliation(s)
- Felix Gonzalez-Lopez
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain.
| | - Carmen Bouza-Miguens
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain
| | - Victor Tejerina
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain
| | - Vasyl Druchkiv
- Department of Research and Development, Clinica Baviera, Valencia, Spain
| | - Blas Mompean
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain
| | - Julio Ortega-Usobiaga
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain
| | - Rafael Bilbao-Calabuig
- Department of Refractive Surgery, Clinica Baviera, Melchor Fernández Almagro, 9, 28029, Madrid, Spain
| |
Collapse
|
14
|
Zhu QJ, Chen WJ, Zhu WJ, Xiao HX, Zhu MH, Ma L, Yuan Y, Song E. Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation. BMC Ophthalmol 2021; 21:199. [PMID: 33957891 PMCID: PMC8101126 DOI: 10.1186/s12886-021-01963-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 04/26/2021] [Indexed: 12/16/2022] Open
Abstract
Background To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. Methods Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 month following implantation. Associations between the postoperative vault and age, ICL size, spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat keratometry (K), steep K, mean K, anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW) diameter obtained by three devices, horizontal and vertical sulcus-to-sulcus (STS) diameter, bright and dark pupil sizes (BPS and DPS) and DPS-BPS were investigated using Spearman’s correlation analysis and stepwise multiple regression analysis. Results The mean vault values at 2 h, 1 day, 1 week, and 1 month after ICL implantation were 672.05 ± 30.72, 389.15 ± 28.33, 517.23 ± 30.76 and 530.12 ± 30.22 μm, respectively. Significant differences were found in the vault values at 2 h, 1 day and 1 week after the operation. The ICL size (β = 0.942; p < 0.001), followed by horizontal STS (β = -0.517; p < 0.001), crystalline LT (β = -0.376; p < 0.001) and vertical STS (β = -0.257; p = 0.017), significantly influenced the vault at 1 month after the operation. The multiple regression equation was expressed as follows: central vault (µm) = -1369.05 + 657.121 × ICL size- 287.408 × horizontal STS − 432.497 × crystalline LT − 137.33 × vertical STS (adjusted R2 = 0.643). Conclusions After ICL implantation, the vault decreased and then increased, but it did not return to the vault value 2 h after surgery. The ICL size, horizontal and vertical STS and crystalline LT are key factors for predicting postoperative vaulting. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-021-01963-x.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Wen-Jing Chen
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Wei-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Hai-Xiang Xiao
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Man-Hui Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Lie Ma
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - You Yuan
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China.
| | - E Song
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| |
Collapse
|
15
|
Yu Z, Li J, Song H. Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia. BMC Ophthalmol 2020; 20:235. [PMID: 32552888 PMCID: PMC7301533 DOI: 10.1186/s12886-020-01482-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 05/25/2020] [Indexed: 01/19/2023] Open
Abstract
Background To compare the intraocular scattering before and after implantation of implantable collamer lens (ICL) V4c for correction of high myopia in a short term. Methods In this study, 38 eyes of 19 patients who underwent the implantation of ICL V4c were followed up for 3 months. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), objective scattering index (OSI), modulation transfer function cutoff frequency (MTF cutoff), strehl ratio (S/R), OV100%, OV20% and OV9% were measured pre- and postoperatively. Meantime, the Pseudophakic Dysphotopsia Questionnaire (PDQ) was scored to evaluate the subjective satisfaction of intraocular scattering pre- and postoperatively. Results The UCVA were − 0.02 ± 0.06, − 0.03 ± 0.07 and − 0.04 ± 0.07 logMAR at 1 week, 1 month and 3 months postoperatively which were significantly better than those preoperatively (P < 0.05). The BCVA were − 0.09 ± 0.09, − 0.09 ± 0.1 and − 0.1 ± 0.11 logMAR at 1 week, 1 month and 3 months after surgery, which were better than those before surgery significantly (t = 15.64, P < 0.05). The mean OSI were 2.37 ± 1.6, 1.63 ± 0.94, 1.5 ± 0.86 and 1.43 ± 1.05 preoperatively, 1 week, 1 month and 3 months postoperatively which was found significant difference (F = 12.92 P < 0.05). No significant differences were found in MTF cut off (F = 0.61, P = 0.62), S/R (F = 0.58, P = 0.36), OV100% (F = 0.966, P = 0.65), OV20% (F = 0.121, P = 0.96) and OV9% (F = 1.01, P = 0.30) between pre- and postoperatively. The PDQ results indicated that intraocular scattering reduced at 3 months after surgery significantly (P < 0.05). Conclusions The ICL V4c implantation for correcting high myopia induced less intraocular scattering and visual disorder than spectacle correction.
Collapse
Affiliation(s)
- Zhe Yu
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, No. 4 Gansu Road, Heping District, Tianjin, People's Republic of China
| | - Jun Li
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, No. 4 Gansu Road, Heping District, Tianjin, People's Republic of China.
| | - Hui Song
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, No. 4 Gansu Road, Heping District, Tianjin, People's Republic of China.
| |
Collapse
|
16
|
Matsuo M, Pajaro S, De Giusti A, Tanito M. Automated anterior chamber angle pigmentation analyses using 360° gonioscopy. Br J Ophthalmol 2019; 104:636-641. [DOI: 10.1136/bjophthalmol-2019-314320] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 07/19/2019] [Accepted: 08/17/2019] [Indexed: 11/04/2022]
Abstract
PurposeTo assess the pigmentation distribution in the iridocorneal angle using an established algorithm with gonioscopically obtained images.MethodsManual and automatically modified Scheie’s pigmentation grading (ie, 0/I=0, II=1 and III/IV=2) of trabecular meshwork was performed using an established algorithm on the 75 open-angle eyes of 75 subjects obtained by automated gonioscopy. All images were collected at the Matsue Red Cross Hospital in 2016. The differences in the pigmentation density were compared statistically between the automated and manual techniques and among the four sectors (ie, inferior, superior, temporal and nasal) and the four quadrants.ResultsThere was substantial agreement between both grading methods (kappa value=0.70). There was no significant difference between the automated and manual grading in any sectors except for the superior (p=0.0004). The automated pigmentation grade was significantly (p<0.05) higher in the inferior sector (mean grade, 1.43) than in the others (mean grade, 0.48~0.76), and it was also significantly (p<0.05) higher in the inferior quadrant (mean grade, 3.56) than in the others (mean grade, 1.64~2.24). The findings were similar for manual grading.ConclusionsThe entire distribution of the pigmentation in the anterior chamber angle was classified successfully using the algorithm, and the automated versus manual grading comparison showed good agreement. The automated pigmentation grading scores in the inferior sector and inferior quadrant were significantly higher than in the others as previously reported. Similar findings also were seen for manual grading.
Collapse
|
17
|
Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c). J Ophthalmol 2019; 2019:7174913. [PMID: 31485347 PMCID: PMC6710753 DOI: 10.1155/2019/7174913] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 07/11/2019] [Indexed: 11/25/2022] Open
Abstract
Purpose To investigate disk halo size changes produced by a glare source after surgical insertion of an implantable collamer lens with a central hole (ICL V4c) for myopia correction. Methods In this prospective study, disk halo size and pupillary light response with a vision monitor were measured preoperatively and at 1 week, 1 month, and 3 months postoperatively. Pupillary light response parameters included contraction amplitude, latency, duration, and velocity; dilation latency, duration, and velocity; and initial, maximum, minimum, and average pupil diameters. Results Forty-two right eyes of 42 patients were enrolled. Postoperative uncorrected distance visual acuity was better than or equal to 20/20 in all eyes. Compared to preoperative values, disk halo size showed no significant difference at 1 week postoperatively (P > 0.05) and then decreased significantly at 1 and 3 months postoperatively (both P < 0.001). Contraction amplitude and velocity, as well as dilation velocity, decreased significantly at all postoperative time points (all P < 0.001). Disk halo size at 3 months postoperatively was significantly correlated with initial (r = 0.446, P=0.003), maximum (r = 0.483, P=0.001), minimum (r = 0.425, P=0.005), and average pupil diameters (r = 0.474, P=0.002). Conclusions After ICL V4c implantation, disk halo size was reduced in the short term. Patients with smaller pupil sizes during pupillary response to light experienced smaller halos after ICL V4c implantation.
Collapse
|
18
|
Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study. Ophthalmol Ther 2017; 6:343-349. [PMID: 28933042 PMCID: PMC5693826 DOI: 10.1007/s40123-017-0109-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Indexed: 10/25/2022] Open
Abstract
INTRODUCTION The objective of this study was to evaluate the changes of the anterior chamber (AC) of the eye after implantable Collamer lens (ICL) implantation in high myopia by using the Pentacam. METHODS The prospective study included 34 high myopic patients (34 eyes). All patients were treated with Visian implantable Collamer lens (ICL) (Staar Surgical Co.) implantation. The Pentacam (Oculus) was used for all cases preoperatively and 1, 3 and 6 months postoperatively. AC angle (ACA), AC volume (ACV), central AC depth (CACD), ICL vault, central corneal thickness (CCT), pupil diameter (PD), K readings and intraocular pressure (IOP) were recorded. RESULTS Our study included 34 eyes of 34 patients, 20 females (59%) and 14 males (41%). Mean ACA was 36.93° ± 4.75° preoperatively, 25.17° ± 5.64° and 25.23° ± 6.05° 1 and 3 months postoperatively (p < 0.001). Mean ACV was 191.24 ± 11.18 mm3 preoperatively, 141.53 ± 16.77 and 142.11 ± 15.89 mm3 1 and 3 months postoperatively (p < 0.001). Mean CACD was 3.59 ± 0.17 mm preoperatively, 2.83 ± 0.24 mm and 2.96 ± 0.25 mm 1 and 3 months postoperatively (p < 0.001). The ICL vault decreased from 0.556 ± 0.033 mm 1 month postoperatively to 0.431 ± 0.056 mm 3 months postoperatively (p < 0.001). There were no statistically significant differences for any of the AC parameters among measurements taken 3, 6 and 12 months postoperatively. There were no statistically significant differences between preoperative and any postoperative measurements of CCT, PD and K readings. CONCLUSIONS ICL implantation for correction of high myopia leads to significant changes in the anterior chamber angle, volume and depth and insignificant changes in the pupil diameter, CCT and K readings.
Collapse
|
19
|
Fernández-Vigo JI, Macarro-Merino A, Fernández-Vigo C, Fernández-Vigo JÁ, De-Pablo-Gómez-de-Liaño L, Fernández-Pérez C, García-Feijóo J. Impacts of Implantable Collamer Lens V4c Placement on Angle Measurements Made by Optical Coherence Tomography: Two-Year Follow-up. Am J Ophthalmol 2017; 181:37-45. [PMID: 28662940 DOI: 10.1016/j.ajo.2017.06.018] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 06/14/2017] [Accepted: 06/19/2017] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine iridocorneal angle changes produced after 2 years of implantable collamer lens (ICL) V4c (STAAR Surgical AG, Nidau, Switzerland) placement by Fourier-domain optical coherence tomography (FD-OCT). DESIGN Prospective interventional case series. METHODS In 54 eyes of 27 myopic subjects FD-OCT iridocorneal angle measurements were made before and 1 month, 3 months, 1 year, and 2 years after ICL implant. Trabecular-iris angle (TIA), angle opening distance 500 μm from the scleral spur (AOD500), and iridotrabecular contact length (TICL) were compared among these time points and the nasal, temporal, and inferior quadrants. RESULTS Preoperative TIAs were 49.5 ± 8.7, 48.3 ± 9.6, and 49.1 ±8.6 degrees for the nasal, temporal and inferior quadrants (P < .001). Corresponding values were 29.9 ± 10.4, 28.4 ± 10.8, and 28.8 ± 9.7 degrees at 1 month and 27.3 ± 8.8, 26.8 ± 8.1, and 28.9 ± 7 degrees at 2 years of follow-up, indicating angle narrowing of 39%-45% and no further narrowing beyond 1 month in the nasal (P = .133), temporal (P = .376), and inferior (P = 1.000) quadrants. Trabecular-iris contact (TIC) was observed in 8 eyes of 8 subjects, mostly only in the temporal quadrant. Mean TICL failed to vary during follow-up (307 ± 288 μm at 3 months and 225 ± 142 μm at 2 years, P = .159). CONCLUSIONS In response to ICL V4c implant, considerable angle narrowing was detected at 1 month but this narrowing remained stable at 2 years. In the 8 cases of TIC, no progression of contact was observed beyond 3 months postimplant.
Collapse
|
20
|
Esteve-Taboada JJ, Domínguez-Vicent A, Ferrer-Blasco T, Alfonso JF, Montés-Micó R. Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients. J Cataract Refract Surg 2017; 43:115-130. [DOI: 10.1016/j.jcrs.2016.05.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Revised: 05/06/2016] [Accepted: 05/25/2016] [Indexed: 12/01/2022]
|
21
|
Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure. J Ophthalmol 2016; 2016:1383289. [PMID: 28053776 PMCID: PMC5178359 DOI: 10.1155/2016/1383289] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 11/04/2016] [Accepted: 11/17/2016] [Indexed: 11/30/2022] Open
Abstract
Purpose. To assess intraocular pressure (IOP), lens vaulting, and anterior chamber (AC) angle width, following V4C implantable Collamer lens (ICL) procedure for myopic refractive error. Methods. A prospective case series that enrolled 54 eyes of 27 patients that were evaluated before and after V4C phakic posterior chamber Collamer lens implantation for correction of myopic refractive error. Preoperative measurement of IOP was done using Goldmann applanation tonometer and anterior chamber angle width using both Van Herick slit lamp grading system and Scheimpflug tomography imaging (Oculus Pentacam). Follow-up of the aforementioned variables was at 1, 6, and 18 months postoperatively, together with ICL vault measurements. Results. The mean baseline IOP of 11.69 ± 2.15 showed a statistically significant (P = 0.002) increase after 1 month that remained unchanged at 6 and 18 months postoperatively, with mean value of 16.07 ± 4.12, 16.07 ± 4.10, and 16.07 ± 4.13, respectively. Pentacam AC angle width showed a statistically significant decrease at 1 (P = 0.025), 6 (P = 0.016), and 18 (P = 0.010) months postoperatively, with mean preoperative value of 40.14 ± 5.49 that decreased to 25.28 ± 5.33, 25.46 ± 5.44, and 25.49 ± 5.38, at 1, 6, and 18 months, respectively. Mean ICL vault showed moderate correlation with Pentacam AC angle width at 1 (r = −0.435) and 6 (r = −0.424) months. Conclusion. V4C ICL implantation resulted in decrease in AC angle width and increase in IOP, within acceptable physiological values at all time points.
Collapse
|
22
|
Senthil S, Choudhari NS, Vaddavalli PK, Murthy S, Reddy J, Garudadri CS. Etiology and Management of Raised Intraocular Pressure following Posterior Chamber Phakic Intraocular Lens Implantation in Myopic Eyes. PLoS One 2016; 11:e0165469. [PMID: 27855172 PMCID: PMC5113895 DOI: 10.1371/journal.pone.0165469] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Accepted: 10/12/2016] [Indexed: 11/18/2022] Open
Abstract
AIM To evaluate the etiology and management of elevated intraocular pressure (IOP) following posterior chamber phakic implantable collamer lens (ICL) surgery. METHODS Between 2009 and 2015, 638 eyes of 359 subjects with refractive myopia, underwent V4b and V4c (CentraFLOW) model ICL implantation. Ocular hypertension (OHT) was defined as IOP of ≥ 22 mm Hg on two separate occasions and elevated IOP with corresponding optic disc or visual field damage was defined as glaucoma. RESULTS Elevated IOP ≥ 22 mm Hg was noted in 33 eyes of 30 subjects (33/638; 5.17%). Median age of subjects with raised IOP was 26 years (Inter quartile range (IQR):22, 29) and median refarctive error was -16 diopters (-19.5, -13). The median follow up was 7.8 months (IQR:0.3, 17.6) and median time for postoperative IOP rise was 12 days, (IQR:2, 24). The various etiologies for elevated IOP were steroid response in 21 eyes (64%; 10 eyes with V4b, 11 eyes with V4c), retained viscoelastic in 5 eyes (15%) (3 with V4b, 2 with V4c), pupillary block in four eyes (12%; 3 with V4b, 1 with V4c), malignant glaucoma in one eye (3%, V4b), and missed pre-existing Juvenile open angle glaucoma (JOAG) in two eyes (6% with V4b). Elevated IOP in 31 eyes resolved with conservative management. One eye (centraFLOW design) with central aquaport block by viscoelastic, needed AC wash and one eye with malignant glaucoma needed parsplana vitrectomy and hyaloidotomy. Ten eyes required longterm (>2 months) antiglaucoma medications (AGM) for IOP control. Except the two eyes with JOAG, none had disc and field damage. CONCLUSION In our series, OHT was seen in 4.85% and glaucoma in 0.3% eyes that underwent V4b and V4c model ICL implantation. Multiple etiologies were noted and steroid induced ocular hypertension was the most common cause of elevated IOP followed by retained viscoelastic and pupillary block. One third of these eyes required longterm AGM for IOP control.
Collapse
Affiliation(s)
- Sirisha Senthil
- VST Glaucoma Center, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
- * E-mail:
| | - Nikhil S. Choudhari
- VST Glaucoma Center, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
| | - Pravin K. Vaddavalli
- Tej Kohli Cornea Services, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
| | - Somasheila Murthy
- Tej Kohli Cornea Services, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
| | - Jagadesh Reddy
- Tej Kohli Cornea Services, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
| | | |
Collapse
|
23
|
High resolution iridocorneal angle imaging system by axicon lens assisted gonioscopy. Sci Rep 2016; 6:30844. [PMID: 27471000 PMCID: PMC4965779 DOI: 10.1038/srep30844] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Accepted: 07/11/2016] [Indexed: 11/08/2022] Open
Abstract
Direct visualization and assessment of the iridocorneal angle (ICA) region with high resolution is important for the clinical evaluation of glaucoma. However, the current clinical imaging systems for ICA do not provide sufficient structural details due to their poor resolution. The key challenges in achieving high quality ICA imaging are its location in the anterior region of the eye and the occurrence of total internal reflection due to refractive index difference between cornea and air. Here, we report an indirect axicon assisted gonioscopy imaging probe with white light illumination. The illustrated results with this probe shows significantly improved visualization of structures in the ICA including TM region, compared to the current available tools. It could reveal critical details of ICA and expected to aid management by providing information that is complementary to angle photography and gonioscopy.
Collapse
|
24
|
Zheng QY, Xu W, Liang GL, Wu J, Shi JT. Preoperative Biometric Parameters Predict the Vault after ICL Implantation: A Retrospective Clinical Study. Ophthalmic Res 2016; 56:215-221. [DOI: 10.1159/000446185] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Accepted: 04/13/2016] [Indexed: 11/19/2022]
|
25
|
Wu Y, Han F, Quan Y, Jiang W, Zhang H, Luo T. Comparison of peripheral iridectomy methods for posterior chamber phakic intraocular lens implantation in patients with brown irides. BMC Ophthalmol 2016; 16:51. [PMID: 27150380 PMCID: PMC4857290 DOI: 10.1186/s12886-016-0229-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Accepted: 04/28/2016] [Indexed: 11/25/2022] Open
Abstract
Background We explore and compare the advantages and disadvantages of different operating methods for a peripheral iridectomy (PI) for phakic posterior chamber implantable contact lens (ICL) implantation in patients with dark-brown irides. Methods Forty-six patients completed this prospective comparative study. Neodymium: yttrium-aluminum-garnet (Nd:YAG) PI was performed in 15 patients (30 eyes) 2 weeks prior to surgery (YAG PI group). Surgical PI was performed in 17 patients (34 eyes) 2 weeks prior to the ICL implantation (preoperative PI group), and intraoperative PI was performed during ICL implantation in 14 patients (28 eyes) (intraoperative PI group). The postoperative recovery of visual acuity, intraoperative complications, operation duration, and patients’ visual disturbances were compared. Results Compared with the preoperative BCVA, the uncorrected visual acuity (UCVA) at 1 week was markedly restored in the preoperative PI group (P = 0.004). UCVA in the three groups of patients had all recovered well at 1 and 3 months after ICL implantation and were significantly better than the preoperative BCVA (all P < 0.01). In the YAG PI group, iris bleeding occurred in nine eyes (30.0 %) and 14 eyes (46.7 %) had pigment dispersion; these values were significantly higher than those in the preoperative PI group (5.9 and 14.7 %, respectively, both P = 0.01). In the intraoperative PI group, elevated high intraocular pressure occurred in four eyes (14.3 %), and eight eyes (28.6 %) had varying degrees of pigment dispersion after ICL implantation. Conclusions For patients with dark-brown irides, surgical PI performed 2 weeks prior to the implantation facilitated better postoperative recovery of visual acuity. Trial registration Current Controlled Trials ISRCTN35178162. Retrospectively registered March 4th, 2013.
Collapse
Affiliation(s)
- Yan Wu
- Department of Ophthalmology, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China
| | - Fei Han
- Department of Ophthalmology, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China
| | - Yan Quan
- Department of Health, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China
| | - Wei Jiang
- Department of Ophthalmology, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China.
| | - Hengdi Zhang
- Department of Ophthalmology, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China
| | - Tao Luo
- Department of Ophthalmology, ChengDu Military General Hospital, ChengDu, 610083, Sichuan Province, China
| |
Collapse
|
26
|
Lee J, Kim Y, Park S, Bae J, Lee S, Park Y, Lee J, Lee JE. Long-term clinical results of posterior chamber phakic intraocular lens implantation to correct myopia. Clin Exp Ophthalmol 2016; 44:481-7. [PMID: 26661832 DOI: 10.1111/ceo.12691] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 11/28/2015] [Accepted: 12/05/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND The aim of this study was to determine whether implantable collamer lens (ICL) implantation to correct myopia is an effective and safe surgical option even after long-term follow up. DESIGN A retrospective observational study was carried out. PARTICIPANTS A total of 281 eyes of 145 myopic patients were included in the study. METHODS Patients underwent ICL implantation and had the follow-up period of at least 5 years (87 ± 18.9 months). MAIN OUTCOME MEASURES Outcome measures included uncorrected and corrected distance visual acuities, refraction for the evaluation of efficacy, safety, stability and predictability, ICL vault and adverse events. RESULTS The final mean logMAR uncorrected and corrected distance visual acuities were 0.02 ± 0.19 and -0.12 ± 0.13, respectively. The mean efficacy and safety indices were 1.04 ± 0.32 and 1.20 ± 0.26. The mean spherical equivalent decreased from -8.74 ± 2.27 diopter (D) to -0.58 ± 0.72 D, and there was high predictability with 69.8% and 87.2% having a postoperative refraction within 0.5 D and 1.0 D, respectively. The mean postoperative vault was changed from 2.53 ± 0.6 to 2.00 ± 0.7. Six (2.1%) eyes developed cataract, and the mean endothelial cell loss was 7.8 ± 8.3%. Increased intraocular pressure was found in two (0.7%) eyes that required the exchange of lenses with different sizes. CONCLUSIONS Implantable collamer lens implantation to correct myopia was an effective and safe surgery with high predictability and stability during long-term follow up. Slight myopic shift and cataract formation related with change in vault should be further evaluated.
Collapse
Affiliation(s)
- Jongsoo Lee
- The Department of Ophthalmology, School of Medicine, Pusan National University, Pusan, Korea.,Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | | | | | | | - Seunguk Lee
- The Department of Ophthalmology, School of Medicine, Kosin University, Pusan, Korea
| | - Youngmin Park
- The Department of Ophthalmology, School of Medicine, Pusan National University, Pusan, Korea.,Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Jonghun Lee
- The Department of Ophthalmology, School of Medicine, Pusan National University, Pusan, Korea
| | - Ji-Eun Lee
- The Department of Ophthalmology, School of Medicine, Pusan National University, Pusan, Korea.,Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
27
|
Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography. Am J Ophthalmol 2016; 162:43-52.e1. [PMID: 26582312 DOI: 10.1016/j.ajo.2015.11.010] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2015] [Revised: 11/04/2015] [Accepted: 11/05/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. DESIGN Prospective interventional case series. METHODS In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3 months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 μm anterior to the scleral spur (AOD500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. RESULTS Preoperative TIA was 48.7 ± 8.7, 48.2 ± 8.7, and 48.7 ± 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P = 1.000). Following ICL implant, corresponding values fell to 31.2 ± 11.5, 30.0 ± 10.7, and 29.7 ± 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 ± 12.3, 30.1 ± 11.9, and 29.8 ± 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P = .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = -.309; P = .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R(2) = .907). CONCLUSIONS Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement.
Collapse
|
28
|
Gimbel HV, Norton NR, Amritanand A. Angle-supported phakic intraocular lenses for the correction of myopia: Three-year follow-up. J Cataract Refract Surg 2015; 41:2179-89. [PMID: 26703294 DOI: 10.1016/j.jcrs.2015.11.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2015] [Revised: 03/26/2015] [Accepted: 04/09/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE To evaluate patient safety and refractive outcomes in eyes with an angle-supported phakic intraocular lens (pIOL), and to assess the correlation between rotation and corneal endothelial cell damage. SETTING Gimbel Eye Centres, Calgary and Edmonton, Alberta, Canada. DESIGN Retrospective cohort study. METHODS This study included patients with moderate to high myopia (range -6.50 to -19.50 diopters [D]) who received the Acrysof Cachet pIOL. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction spherical equivalent (MRSE), endothelial cell density (ECD), and IOL rotation. RESULTS This study evaluated 119 eyes of 61 patients. The mean ECD decrease from preoperative measurements was 3.11% (n = 46), with a mean IOL rotation of 10.6 degrees (n = 35) at the 3-year postoperative visit. Of the 49 eyes at the 3-year visit measured for UDVA, 98.0% were 20/40 or better and 77.6% were 20/20 or better. The MRSE improved from a preoperative mean of -9.26 diopters (D) ± 2.43 (SD) (range -19.50 to -5.63 D) to -0.33 ± 0.61 D (range -3.12 to +0.71 D) at the 3-year visit. The residual refractive error was within ±0.50 D of the target refraction for 78.4% and within ±1.00 D for 92.2% of the 51 eyes. The study included one bilateral pIOL removal due to endothelial cell loss, one case of synechia, and one case of subtle pupil ovalization. CONCLUSIONS No correlation between IOL rotation and ECD decrease was found (R(2) = 0.0143); the pIOL provided promising refractive outcomes and acceptable safety in patients with moderate to high myopia. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Howard V Gimbel
- From the Gimbel Eye Centre (Gimbel, Amritanand), Calgary, Alberta, Canada; Loma Linda University (Gimbel, Norton), Loma Linda, California, USA.
| | - Nicholas R Norton
- From the Gimbel Eye Centre (Gimbel, Amritanand), Calgary, Alberta, Canada; Loma Linda University (Gimbel, Norton), Loma Linda, California, USA
| | - Anika Amritanand
- From the Gimbel Eye Centre (Gimbel, Amritanand), Calgary, Alberta, Canada; Loma Linda University (Gimbel, Norton), Loma Linda, California, USA
| |
Collapse
|
29
|
Abstract
PURPOSE To observe the changes in pupil size under photopic and scotopic conditions after Implantable Collamer Lens (ICL) implantations in eyes with high myopia. METHODS The ICL was implanted in 90 eyes belonging to 45 patients with high myopia. Photopic pupil diameters, scotopic pupil diameters, anterior chamber depths, and ICL vaults were examined at the preoperative, postoperative 1-month, and postoperative 3-month stages. The preoperative and postoperative photopic pupil diameters and scotopic pupil diameters were also compared with each other to note the differences between them. The correlations between preoperative and postoperative pupil diameter changes under different light conditions and presurgical refractive error were analyzed alongside patient's age and ICL vault. RESULTS Pupil diameters at both postoperative 1-month and postoperative 3-month stages were smaller than those before operation in distinct light environments, as well as pupil constriction amplitude. Correlation analysis showed that there was a statistically significant correlation between pupil diameter changes under different light conditions and presurgical refractive error at 1 month and 3 months after ICL implantation; pupil diameter decreased more when presurgical refractive error powers were less myopic. Statistically significant correlations were not found, however, with patient's age and ICL vault. Postoperative 1-month and mean postoperative 3-month anterior chamber depths were decreased when compared with preoperative anterior chamber depths. Statistically significant correlations were found in change in preoperative and postoperative anterior chamber depth and ICL vault. No statistically significant difference was found between ICL vault at the postoperative 1-month and postoperative 3-month stages. CONCLUSIONS Pupil diameter may decrease at the 1- and 3-month stages after ICL implantation under both photopic and scotopic conditions. This indicates that reduction of pupil diameter may be caused by mechanical contact between the ICL and the posterior iris surface.
Collapse
|
30
|
Cao X, Tong J, Wang Y, Zhou T, Ye B, Li X, Shen Y. Long-term ultrasound biomicroscopy observation of position changes of a copolymer posterior chamber phakic intraocular lens. J Cataract Refract Surg 2015; 40:1454-61. [PMID: 25135537 DOI: 10.1016/j.jcrs.2013.12.022] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 12/02/2013] [Accepted: 12/19/2013] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate longitudinal changes in Implantable Collamer Lens phakic intraocular lens (pIOL) position after implantation. SETTING Department of Ophthalmology, Zhejiang University, Hangzhou, China. DESIGN Retrospective case series. METHODS Myopic eyes that had pIOL implantation with a follow-up of at least 24 months were evaluated. Ultrasound biomicroscopy examinations were performed at each visit. RESULTS The study enrolled 62 eyes (31 patients; 22 women, 9 men) ranging in age from 21 to 46 years. The manifest spherical equivalent ranged from -8.25 to -18.75 diopters. A significant increase (mean 36 μm±50 [SD]) in the endothelium-anterior pIOL distance occurred between 1 month and 3 months (P=.000); afterward, the distance decreased slowly (P>.05). The largest decrease (mean 47±17 μm) in central vault occurred between 1 month and 3 months (P=.009). The largest decrease (mean 21±14 μm) in peripheral vault occurred between 1 month and 3 months (P=.000). CONCLUSIONS A significant increase in the endothelium-anterior pIOL distance occurred from 1 month to 3 months postoperatively, after which a slight decrease occurred over time. Central vault and peripheral vault had a tendency to decrease over time. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Xinfang Cao
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China.
| | - Jianping Tong
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Yang Wang
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Tian'an Zhou
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Bei Ye
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Xiuyi Li
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Ye Shen
- From the Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| |
Collapse
|
31
|
Almalki S, Abubaker A, Alsabaani NA, Edward DP. Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia. Int Ophthalmol 2015; 36:259-65. [PMID: 26265323 DOI: 10.1007/s10792-015-0112-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Accepted: 08/04/2015] [Indexed: 10/23/2022]
Abstract
The purpose of this study is to present the causes and visual acuity outcomes in patients with elevated intraocular pressure (IOP) following implantable collamer lens (ICL) implantation. A chart review identified patients who developed high IOP at any postoperative examination and a minimum follow-up period of 3 months after ICL implantation. Data are reported out to 6 months postoperatively. Outcome measures included causes of elevated IOP, best-corrected visual acuity (BCVA) at last visit, number of glaucoma medications, other interventions, and glaucomatous damage. Elevated IOP occurred in 58 (10.8 %) of 534 eyes that received ICL. The mean age was 28 ± 7.2 years. The preoperative IOP was 16.3 ± 1.2 mmHg. Elevated IOP most commonly occurred on the first postoperative day (23/58 (39.7 %) eyes) due to retained viscoelastic. This was followed by steroid response in 22/58 (37.9 %) eyes at 2-4 weeks postoperatively. IOP elevation in 6 (10.3 %) eyes was related to high ICL vault and pupillary block, and in 4 (6.9 %) eyes due to synechial angle closure. At last visit, BCVA was 20/40 or better in 56/58 (96.6 %) eyes, and 5/58 (8.6 %) eyes remained on glaucoma medications due to persistent steroid response (2 eyes), synechial angle closure glaucoma (1 eye), and other causes (2 eyes). One eye showed glaucomatous damage. Two eyes with high vault and elevated IOP underwent ICL explantation. There is a moderate risk of transiently developing elevated IOP after ICL implantation. Thorough removal of viscoelastic and use of anti-glaucoma medications during steroid use will reduce the majority of cases with postoperative IOP elevation.
Collapse
Affiliation(s)
- Salem Almalki
- King Khaled Eye Specialist Hospital, Al Aroubah Road, PO Box 7191, Riyadh, Kingdom of Saudi Arabia.
| | | | | | - Deepak P Edward
- King Khaled Eye Specialist Hospital, Al Aroubah Road, PO Box 7191, Riyadh, Kingdom of Saudi Arabia.,Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
32
|
Lim DH, Lee MG, Chung ES, Chung TY. Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth. Am J Ophthalmol 2014; 158:447-54.e1. [PMID: 24952274 DOI: 10.1016/j.ajo.2014.06.005] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Revised: 06/11/2014] [Accepted: 06/13/2014] [Indexed: 11/25/2022]
Abstract
PURPOSE To investigate visual outcomes of Visian implantable Collamer lens (ICL) implantation in eyes with a shallow anterior chamber depth (ACD). DESIGN Retrospective, noncomparative, interventional case series. METHODS Medical charts of the patients with a low ACD of 2.8 mm or less who underwent implantable Collamer lens implantation were reviewed. To evaluate efficacy and safety, preoperative and postoperative uncorrected visual acuity, manifest refractive spherical equivalent (MRSE), endothelial cell count, intraocular pressure, angle opening distance at 500 μm from the scleral spur, trabecular-iris angle, and postoperative central vault were analyzed. RESULTS The mean follow-up period for 18 eyes of 10 patients was 24.67 ± 15.09 months (range, 10 to 51 months). The preoperative ACD was 2.71 ± 0.08 mm (range, 2.42 to 2.79 mm). There was no postoperative endothelial cell count reduction to less than 2000 cells/mm(2) or intraocular pressure elevation to more than 21 mm Hg. The differences between preoperative and postoperative angle opening distance at 500 μm from the scleral spur and trabecular-iris angle were statistically significant (P = .000, both). The mean postoperative central vault was 331.83 ± 181.28 μm (range, 174 to 811 μm), which was significantly less than expected (P = .000). Anterior subcapsular cataract was observed in 2 eyes (11.1%). CONCLUSIONS Implantable Collamer lens implantation in shallow ACD eyes exhibited good visual outcomes. Severe complications did not develop over relatively long periods. Two cases of anterior subcapsular cataract developed in older aged patients, suggesting the need for thorough preoperative warning about the risk of cataract. In addition, a postoperative vault less than expected should be taken into account when determining implantable Collamer lens size in lower ACD eyes.
Collapse
|
33
|
Intraocular pressure during the early postoperative period after 100 consecutive implantations of posterior chamber phakic intraocular lenses with a central hole. J Cataract Refract Surg 2014; 39:1859-63. [PMID: 24427793 DOI: 10.1016/j.jcrs.2013.06.020] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
PURPOSE To study changes in intraocular pressure (IOP) during the early postoperative period in eyes having implantation of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens V4c). SETTING Clínica Baviera, Instituto Oftalmológico Europeo, Madrid, Spain. DESIGN Case series. METHODS This retrospective review included the first consecutive eyes having implantation of a spherical or toric myopic pIOL with a central hole at Clínica Baviera from December 2011 to June 2012 by the same experienced surgeon. The IOP was evaluated preoperatively and 1 day, 1 week, and 1 month postoperatively. RESULTS The study comprised 100 eyes. The mean IOP changed from 14.6 mm Hg ± 3.4 (SD) (range 8 to 26 mm Hg) preoperatively to 14.5 ± 4.6 mm Hg (range 6 to 30 mm Hg) 1 day postoperatively, 14.2 ± 4.2 mm Hg (range 6 to 29 mm Hg) at 1 week, and 12.3 ± 3.4 mm Hg (range 9 to 24 mm Hg) at 1 month. No statistically significant changes were detected over time postoperatively (P>.2). No perioperative complications associated with the implantation of the pIOL were recorded. No pIOLs were explanted, no toric pIOL rotation was detected, and no pupillary block or acute angle closure was observed. CONCLUSION The short-term clinical data for the new pIOL model with the central hole (KS-Aquaport) suggest that it is a safe and effective means for controlling postoperative IOP.
Collapse
|
34
|
Evaluation of a Toric Implantable Collamer Lens After Corneal Collagen Crosslinking in Treatment of Early-Stage Keratoconus. Cornea 2014; 33:475-80. [DOI: 10.1097/ico.0000000000000094] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
35
|
Rhee TK, Park JH, Kang HJ, Kwon YA, Song SW, Kim BY, Chung JL. Comparison of Anterior Segment Measurements Using Scanning-Slit Topography and Optical Low-Coherence Reflectometry (OLCR) Biometry. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2014. [DOI: 10.3341/jkos.2014.55.5.656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Taek Kwan Rhee
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Ji Hyun Park
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
- Daesung Yonsei Eye Clinic, Bucheon, Korea
| | - Hyo Jeong Kang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
- Eyelove Eye Center, Daejeon, Korea
| | - Young A Kwon
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Sang Wroul Song
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Byoung Yeop Kim
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Jae Lim Chung
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| |
Collapse
|
36
|
McCaughey MV, Mifflin T, Fenzl CR, Goldsmith J, Moshirfar M. Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia. ACTA ACUST UNITED AC 2014; 4:107-111. [PMID: 25485179 DOI: 10.4236/ojoph.2014.44017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To report a case of bilateral glaucoma related to pseudophacomorphic mechanism in one eye and pupillary block in the other eye after Visian Implantable Collamer Lens (ICL, STAAR Surgical) insertion. METHODS A 44 year-old female with high myopia underwent bilateral ICL implantation of MICL12.6 after sulcus diameter measurements were performed by Pentacam. RESULTS Pseudophacomorphic glaucoma-related angle closure occurred due to lens oversizing in the right eye. The mechanism was relieved via ICL explantation. In the left eye, pupillary block developed in a subacute manner after closure of the peripheral iridotomy (PI). The attack was ameliorated by reestablishing patency of the iridotomy. CONCLUSIONS ICL-related glaucomatous attacks may result from improper sizing as well as from placement of a single PI. Identification of the proper mechanism is vital as treatments differ significantly. In pseudophacomorphic glaucoma, explantation is needed. In pupillary block glaucoma, treatment involves establishment of a patent PI.
Collapse
Affiliation(s)
| | - Thomas Mifflin
- John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Carlton R Fenzl
- John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jason Goldsmith
- John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Majid Moshirfar
- Francis I. Proctor Foundation, University of California San Francisco, San Francisco, USA
| |
Collapse
|
37
|
Torun N, Bertelmann E, Klamann MKJ, Maier AK, Liekfeld A, Gonnermann J. Posterior chamber phakic intraocular lens to correct myopia: long-term follow-up. J Cataract Refract Surg 2013; 39:1023-8. [PMID: 23664355 DOI: 10.1016/j.jcrs.2013.01.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/19/2013] [Accepted: 01/22/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the long-term safety and efficacy of a refractive phakic intraocular lens (pIOL) (PRL) to correct moderate to high myopia. SETTING Department of Ophthalmology, University Medicine Charité Berlin, Berlin, Germany. DESIGN Retrospective cohort study. METHODS Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure, endothelial cell loss, and adverse events were evaluated. RESULTS The study enrolled 53 eyes (mean spherical equivalent [SE] -12.17 diopters [D] ± 4.12 [SD]) of 29 patients. The mean age was 34.6 ± 9.2 years and the mean follow-up, 86 ± 21.2 months. The mean UDVA improved from 1.37 ± 0.28 logMAR preoperatively to 0.14 ± 0.19 logMAR at the last postoperative visit (P<.05). The mean CDVA improved from 0.10 ± 0.18 logMAR to -0.01 ± 0.09 logMAR (P<.05). The overall mean efficacy index and mean safety index were 0.9 and 1.21, respectively, at the last follow-up visit. The mean endothelial cell loss at the last follow-up was 6.4%. The complications were slight posterior chamber (PC) pIOL decentration (5 eyes, 9.4%), severe PC pIOL decentration resulting in pIOL removal (1 eye, 1.8%), glaucoma (4 eyes, 7.5%), clinically significant cortical lens opacification resulting in cataract surgery (4 eyes, 7.5%), clinically asymptomatic anterior subcapsular cataract formation (6 eyes, 11.3%), and retinal detachment (2 eyes, 3.8%). CONCLUSIONS Posterior chamber phakic pIOL implantation to correct moderate to high myopia provided predictable and stable refractive results but with a high rate of serious complications over the long term. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Necip Torun
- Departments of Ophthalmology, University Medicine Charité Berlin, Berlin, Germany.
| | | | | | | | | | | |
Collapse
|
38
|
Pak KY, Kim HS, Lee JW. A Case of Pigmentary Glaucoma after Posterior Chamber Phakic Intraocular Lens Implantation. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2013. [DOI: 10.3341/jkos.2013.54.6.994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Kang Yeun Pak
- Department of Ophthalmology, Pusan National University School of Medicine, Busan, Korea
| | | | - Ji Woong Lee
- Department of Ophthalmology, Pusan National University School of Medicine, Busan, Korea
| |
Collapse
|
39
|
Ghoreishi M, Masjedi A, Nasrollahi K, Rahgozar A, Jenab K, Fesharaki H. Artiflex versus STAAR implantable contact lenses for correction of high myopia. Oman J Ophthalmol 2012; 4:116-9. [PMID: 22279398 PMCID: PMC3263163 DOI: 10.4103/0974-620x.91266] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Purpose: To compare two phakic intraocular lenses, Artiflex and STAAR® implantable contact lens (ICL), in high myopia. Setting: Isfahan Ophthalmology Clinic, Iran. Materials and Methods: In a randomized, prospective clinical trial study, 40 eyes of 20 patients who came to Isfahan ophthalmology clinic to correct their refractive error were examined. Artiflex was inserted in 20 eyes and ICL in the other 20 eyes. After 1 year, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), contrast sensitivity, intraocular pressure (IOP), and specular microscopy of corneal endothelium were assessed in both the groups. Results: In this study, there was no statistical difference between UCVA, BCVA, IOP, cataract incidence, contrast sensitivity, and specular microscopy, 1 year after surgery. 40% of eyes in the Artiflex group developed anterior chamber cell and flare reaction 1 year postoperatively, but no patient in the ICL group developed the same. So, there is obvious difference in the rate of anterior chamber cell and flare reaction between these two groups. Conclusion: These two lenses have similar outcomes except in the incidence rate of anterior chamber cell and flare reaction that is greater in the Artiflex group. So, these two lenses are safe with predictable outcome in treating high myopia.
Collapse
Affiliation(s)
- Mohammad Ghoreishi
- Department of Ophthalmology, Isfahan University of Medical Sciences, Persian Eye Clinic, Isfahan, Iran
| | | | | | | | | | | |
Collapse
|
40
|
Fernandes P, González-Méijome JM, Madrid-Costa D, Ferrer-Blasco T, Jorge J, Montés-Micó R. Implantable collamer posterior chamber intraocular lenses: a review of potential complications. J Refract Surg 2011; 27:765-76. [PMID: 21710954 DOI: 10.3928/1081597x-20110617-01] [Citation(s) in RCA: 170] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2010] [Accepted: 05/27/2011] [Indexed: 01/31/2023]
Abstract
PURPOSE To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported complications using the latest ICL designs. RESULTS Cataract was the major postoperative complication reported: 136 (5.2%) in 2592 eyes. Of those, 43.4% (n=59) were reported within 1 year, 15.4% (n=21) between 1 and 3 years, and 35.3% (n=48) ≥ 3 years after ICL implantation. Twenty-one (15.4%) cataracts were reported as surgically induced, 46 (33.8%) eyes had poor vault (<200 μm), and cataract surgery was carried out in 27.9% (n=38) of eyes. Early acute intraocular pressure increase was also reported to be relatively frequent, whereas acute pupillary block was less frequent and mostly resolved with additional iridotomies. A total of 42 ICLs were explanted due to cataract and IOP. Reported endothelial cell loss varied from 9.9% at 2 years to 3.7% 4 years postoperatively. This loss was reported to be more pronounced within the first 1 to 2 years, with stability or lower progression after that time. CONCLUSIONS The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon's learning curve, might be factors in the decreased occurrence of postoperative complications reported currently.
Collapse
|
41
|
Alfonso JF, Baamonde B, Fernández-Vega L, Fernandes P, González-Méijome JM, Montés-Micó R. Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up. J Cataract Refract Surg 2011; 37:873-80. [DOI: 10.1016/j.jcrs.2010.11.040] [Citation(s) in RCA: 116] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2010] [Revised: 10/21/2010] [Accepted: 11/03/2010] [Indexed: 11/30/2022]
|
42
|
Mertens EL. Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes. Clin Ophthalmol 2011; 5:369-75. [PMID: 21468348 PMCID: PMC3065582 DOI: 10.2147/opth.s7259] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Indexed: 12/04/2022] Open
Abstract
Purpose: The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. Methods: Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was −4. 98 ± 3.49 diopters (D) (range: 0 to −13 D), and mean cylinder was −2.62 ± 0.97 D (range: −1.00 to −5.00 D). Main outcomes measures evaluated during a 12-month follow-up included uncorrected visual acuity (UCVA), refraction, best-corrected visual acuity (BCVA), vault, and adverse events. Results: At 12 months the mean Snellen decimal UCVA was 0.87 ± 0.27 and mean BCVA was 0.94 ± 0.21, with an efficacy index of 1.05. More than 60% of the eyes gained ≥1 line of BCVA (17 eyes, safety index of 1.14). The treatment was highly predictable for spherical equivalent (r2 = 0.99) and astigmatic components: J0 (r2 = 0.99) and J45 (r2 = 0.90). The mean spherical equivalent dropped from −7.29 ± 3.4 D to −0.17 ± 0.40 D at 12 months. Of the attempted spherical equivalent, 76.7% of the eyes were within ±0.50 D and 97.7% eyes were within ±1.00 D, respectively. For J0 and J45, 97.7% and 83.7% were within ±0.50 D, respectively. Conclusion: The results of the present study support the safety, efficacy, and predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism.
Collapse
|
43
|
Alfonso JF, Baamonde B, Madrid-Costa D, Fernandes P, Jorge J, Montés-Micó R. Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism. J Cataract Refract Surg 2010; 36:1349-57. [PMID: 20656159 DOI: 10.1016/j.jcrs.2010.02.022] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2009] [Revised: 02/02/2010] [Accepted: 02/02/2010] [Indexed: 11/27/2022]
|
44
|
Alfonso JF, Fernández-Vega L, Lisa C, Fernandes P, González-Méijome JM, Montés-Micó R. Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus. J Cataract Refract Surg 2010; 36:906-16. [PMID: 20494760 DOI: 10.1016/j.jcrs.2009.11.032] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2009] [Revised: 11/26/2009] [Accepted: 11/28/2009] [Indexed: 11/27/2022]
Abstract
PURPOSE To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This prospective study comprised keratoconic eyes that had implantation of a toric Intraocular Collamer Lens. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and postoperative complications were evaluated 1, 3, 6, and 12 months postoperatively. RESULTS Preoperatively, the mean spherical equivalent in the 30 eyes (21 patients) was -5.38 diopters (D) +/- 3.26 (SD) (range -13.50 to -0.63 D) and the mean cylinder, -3.48 +/- 1.24 D (range -1.75 to -6.00 D). At 12 months, 86.7% of the eyes were within +/-0.50 D of the attempted refraction and all eyes were within +/-1.00 D. For the astigmatic components J0 and J45, 83.3% of eyes and 86.7% of eyes, respectively, were within +/-0.50 D. The mean Snellen UDVA was 0.81 +/- 0.20 and the mean CDVA, 0.83 +/- 0.18; CDVA was 20/40 or better in 29 eyes 96.7% of eyes and 20/25 or better in 22 eyes (73.3%). No eyes lost more than 2 lines of CDVA; 29 eyes (96.7%) maintained or gained 1 or more lines. The efficacy index was 1.07 and the safety index, 1.16. There were no complications or adverse events. CONCLUSIONS The results confirm that toric ICL implantation is a predictable, effective procedure to correct ametropia in eyes with keratoconus. Predictability and stability were achieved early and remained fairly stable up to 12 months.
Collapse
Affiliation(s)
- José F Alfonso
- Fernández-Vega Ophthalmological Institute, Surgery Department, School of Medicine, University of Oviedo, Oviedo, Spain.
| | | | | | | | | | | |
Collapse
|
45
|
Venkataraman A, Mardi SK, Pillai S. Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter. Indian J Ophthalmol 2010; 58:219-22. [PMID: 20413925 PMCID: PMC2886253 DOI: 10.4103/0301-4738.62647] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32mm (SD) with the Orbscan and 11.92 ± 0.33mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan.
Collapse
|
46
|
Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism. J Cataract Refract Surg 2010; 36:568-76. [DOI: 10.1016/j.jcrs.2009.10.052] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2009] [Revised: 10/12/2009] [Accepted: 10/31/2009] [Indexed: 11/21/2022]
|
47
|
Alfonso JF, Lisa C, Abdelhamid A, Fernandes P, Jorge J, Montés-Micó R. Three-year follow-up of subjective vault following myopic implantable collamer lens implantation. Graefes Arch Clin Exp Ophthalmol 2010; 248:1827-35. [PMID: 20333528 DOI: 10.1007/s00417-010-1322-0] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2009] [Revised: 01/18/2010] [Accepted: 02/04/2010] [Indexed: 11/24/2022] Open
|
48
|
Toric intraocular Collamer lens for high myopic astigmatism after penetrating keratoplasty. J Cataract Refract Surg 2009; 35:2161-3. [DOI: 10.1016/j.jcrs.2009.06.034] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2009] [Revised: 06/04/2009] [Accepted: 06/07/2009] [Indexed: 11/17/2022]
|
49
|
Evaluation of pupil diameter after posterior chamber phakic intraocular lens implantation. Eye (Lond) 2009; 24:588-94. [DOI: 10.1038/eye.2009.170] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
50
|
Alfonso JF, Lisa C, Palacios A, Fernandes P, González-Méijome JM, Montés-Micó R. Objective vs subjective vault measurement after myopic implantable collamer lens implantation. Am J Ophthalmol 2009; 147:978-983.e1. [PMID: 19285654 DOI: 10.1016/j.ajo.2009.01.006] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2008] [Revised: 01/11/2009] [Accepted: 01/12/2009] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN Observational cross-sectional study. METHODS SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES Subjective vault classified in 5 levels assessed using an optical section during slit-lamp examination. Objective vault was measured with Visante OCT (Carl Zeiss Meditec Inc, Dublin, California, USA). RESULTS Average values of objective and subjective vault were 414 +/- 228 microm and 2.1 +/- 1.0, respectively and both parameters were highly correlated (r = 0.82; P < .001). Differences in average objective vault were statistically significant among the 5 groups of subjective vault (P < .001). Subjective vault 0 corresponded to a mean OCT value of 62 +/- 49 microm with 99% confidence interval (CI) [38; 86] microm; eyes with vault 1 to 203 +/- 93 microm with 99% CI [176; 230] microm; eyes with vault 2 to 402 +/- 131 microm with 99% CI [378; 425] microm; eyes with vault 3 to 594 +/- 146 microm, 99% CI [554; 633] microm; and vault 4 to 794 +/- 182 microm with 99% CI [713; 875] microm. CONCLUSIONS Subjective and objective values of vault are highly correlated. In 99% of cases within the CI, objective values for eyes subjectively classified within a certain level vary within a narrow interval (+/-25 to 80 microm) around the mean value, and this interval is characteristic of each subjective level.
Collapse
Affiliation(s)
- José F Alfonso
- Fernández-Vega Ophthalmological Institute, University of Oviedo, Oviedo, Spain.
| | | | | | | | | | | |
Collapse
|