Nagata M, Matsushima H, Mukai K, Senoo T, Nishi O. Inhibition of anterior capsule opacification and contraction by the elevated anterior rim of the intraocular lens optic. Jpn J Ophthalmol 2023; 67:693-698. [PMID: 37535105 DOI: 10.1007/s10384-023-01013-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/06/2023] [Indexed: 08/04/2023]
Abstract
PURPOSE To verify the anterior capsule opacification (ACO) and contraction (ACC) of the ZCB00V intraocular lens (IOL), made of the same material as the AR40e with a high ACC rate. STUDY DESIGN Retrospective cohort study. METHODS We evaluated 35 patients at 1 week, 1, 3 and 6 months post phacoemulsification with either a ZCB00V (n = 35) or FY-60AD (n = 34) IOL implantation. The ACC rate was calculated using retroillumination images of the anterior segment, and the ACO was measured using anterior segment photographs and image analysis software. The contact grade between the IOL and anterior capsule was estimated from the Pentacam® images. RESULTS The postoperative ACC rates (mean ± standard deviation) at 3 months were 1.03%±2.54% for the ZCB00V and, and 7.12%±9.47% for the FY-60AD. The ZCB00V-implanted eyes showed a significantly lower postoperative ACC at 1 week, 3 months, and 6 months (P < 0.01). On the other hand, the FY-60AD-implanted eyes had more pronounced ACO, and a significantly larger area of opacification (62.24%±21.32% vs. 16.90%±8.34%; P = 0.0005). Pentacam® analysis revealed a space between the anterior capsule and IOL surface in the ZCB00V-implanted eyes, whereas the anterior capsule firmly adhered to the IOL surface in the FY-60AD-implanted eyes. CONCLUSION The ACC and ACO were significantly lower in eyes with ZCB00V IOLs compared to those with the FY-60AD. The anterior segment image analysis revealed that the elevated anterior rim of the ZCB00V IOL prevented adhesion between the anterior capsule and IOL optic surface, suggesting an open capsule effect.
Collapse
Affiliation(s)
- Mayumi Nagata
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Tochigi, 321-0293, Japan.
| | - Hiroyuki Matsushima
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Tochigi, 321-0293, Japan
| | - Koichiro Mukai
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Tochigi, 321-0293, Japan
| | - Tadashi Senoo
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Tochigi, 321-0293, Japan
| | | |
Collapse
|
2
|
Maedel S, Evans JR, Harrer-Seely A, Findl O. Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery. Cochrane Database Syst Rev 2021; 8:CD012516. [PMID: 34398965 PMCID: PMC8406949 DOI: 10.1002/14651858.cd012516.pub2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Posterior capsule opacification (PCO) is a clouding of the posterior part of the lens capsule, a skin-like transparent structure, which surrounds the crystalline lens in the human eye. PCO is the most common postoperative complication following modern cataract surgery with implantation of a posterior chamber intraocular lens (IOL). The main symptoms of PCO are a decrease in visual acuity, 'cloudy', blurred vision and reduced contrast sensitivity. PCO is treated with a neodymium:YAG (Nd:YAG) laser to create a small opening in the opaque capsule and regain a clear central visual axis. This capsulotomy might cause further ocular complications, such as raised intraocular pressure or swelling of the central retina (macular oedema). This procedure is also a significant financial burden for health care systems worldwide. In recent decades, there have been advances in the selection of IOL materials and optimisation of IOL designs to help prevent PCO formation after cataract surgery. These include changes to the side structures holding the lens in the centre of the lens capsule bag, called IOL haptics, and IOL optic edge designs. OBJECTIVES To compare the effects of different IOL optic edge designs on PCO after cataract surgery. SEARCH METHODS We searched CENTRAL, Ovid MEDLINE, Ovid Embase, Latin American and Caribbean Health Sciences Literature Database (LILACS), the ISRCTN registry, ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 17 November 2020. SELECTION CRITERIA We included randomised controlled trials (RCTs) that compared different types of IOL optic edge design. Our prespecified primary outcome was the proportion of eyes with Nd:YAG capsulotomy one year after surgery. Secondary outcomes included PCO score, best-corrected distance visual acuity (BCDVA) and quality of life score at one year. Due to availability of important long-term data, we also presented data at longer-term follow-up which is a post hoc change to our protocol. DATA COLLECTION AND ANALYSIS We used standard methods expected by Cochrane and the GRADE approach to assess the certainty of the evidence. MAIN RESULTS We included 10 studies (1065 people, 1834 eyes) that compared sharp- and round-edged IOLs. Eight of these studies were within-person studies whereby one eye received a sharp-edged IOL and the fellow eye a round-edged IOL. The IOL materials were acrylic (2 studies), silicone (4 studies), polymethyl methacrylate (PMMA, 3 studies) and different materials (1 study). The studies were conducted in Austria, Germany, India, Japan, Sweden and the UK. Five studies were at high risk of bias in at least one domain. We judged two studies to be at low risk of bias in all domains. There were few cases of Nd:YAG capsulotomy at one year (primary outcome): 1/371 in sharp-edged and 4/371 in round-edged groups. The effect estimate was in favour of sharp-edged IOLs but the confidence intervals were very wide and compatible with higher or lower chance of Nd:YAG capsulotomy in sharp-edged compared with round-edged lenses (Peto odds ratio (OR) 0.30, 95% CI 0.05 to 1.74; I2 = 0%; 6 studies, 742 eyes). This corresponds to seven fewer cases of Nd:YAG capsulotomy per 1000 sharp-edged IOLs inserted compared with round-edged IOLs (95% CI 9 fewer to 7 more). We judged this as low-certainty evidence, downgrading for imprecision and risk of bias. A similar reduced risk of Nd:YAG capsulotomy in sharp-edge compared with round-edge IOLs was seen at two, three and five years but as the number of Nd:YAG capsulotomy events increased with longer follow-up this effect was more precisely measured at longer follow-up: two years, risk ratio (RR) 0.35 (0.16 to 0.80); 703 eyes (6 studies); 89 fewer cases per 1000; three years, RR 0.21 (0.11 to 0.41); 538 eyes (6 studies); 170 fewer cases per 1000; five years, RR 0.21 (0.10 to 0.45); 306 eyes (4 studies); 331 fewer cases per 1000. Data at 9 years and 12 years were only available from one study. All studies reported a PCO score. Four studies reported the AQUA (Automated Quantification of After-Cataract) score, four studies reported the EPCO (Evaluation of PCO) score and two studies reported another method of quantifying PCO. It was not possible to pool these data due to the way they were reported, but all studies consistently reported a statistically significant lower average PCO score (of the order of 0.5 to 3 units) with sharp-edged IOLs compared with round-edged IOLs. We judged this to be moderate-certainty evidence downgrading for risk of bias. The logMAR visual acuity score was lower (better) in eyes that received a sharp-edged IOL but the difference was small and likely to be clinically unimportant at one year (mean difference (MD) -0.06 logMAR, 95% CI -0.12 to 0; 2 studies, 153 eyes; low-certainty evidence). Similar effects were seen at longer follow-up periods but non-statistically significant data were less fully reported: two years MD -0.01 logMAR (-0.05 to 0.02); 2 studies, 311 eyes; three years MD -0.09 logMAR (-0.22 to 0.03); 2 studies, 117 eyes; data at five years only available from one study. None of the studies reported quality of life. Very low-certainty evidence on adverse events did not suggest any important differences between the groups. AUTHORS' CONCLUSIONS This review provides evidence that sharp-edged IOLs are likely to be associated with less PCO formation than round-edged IOLs, with less Nd:YAG capsulotomy. The effects on visual acuity were less certain. The impact of these lenses on quality of life has not been assessed and there are only very low-certainty comparative data on adverse events.
Collapse
Affiliation(s)
- Sophie Maedel
- Department of Ophthalmology, Hanusch Hospital, Vienna, Austria
| | - Jennifer R Evans
- Cochrane Eyes and Vision, ICEH, London School of Hygiene & Tropical Medicine, London, UK
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | | | - Oliver Findl
- Department of Ophthalmology, Hanusch Hospital, Vienna, Austria
| |
Collapse
|
3
|
Tandogan T, Auffarth GU, Son HS, Merz P, Choi CY, Khoramnia R. In-vitro glistening formation in six different foldable hydrophobic intraocular lenses. BMC Ophthalmol 2021; 21:126. [PMID: 33685428 PMCID: PMC7938589 DOI: 10.1186/s12886-021-01879-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/18/2021] [Indexed: 11/26/2022] Open
Abstract
Background Glistenings describe small, refractile microvacuoles that may arise within the intraocular lens (IOL) material and reduce the patients’ quality of vision. Lenses composed of hydrophobic acrylic material are particularly affected by glistening formation. In this study, we compared the tendency of glistening formation in six different types of hydrophobic acrylic intraocular lenses (IOLs). Methods We used a well-established accelerated laboratory method to develop glistenings in the following IOLs: Vivinex XY1 (Hoya), AcrySof SN60WF (Alcon), Tecnis ZCB00 (AMO), Avansee PN6A (Kowa), Aktis SP NS-60YG (Nidek), and CT Lucia 601P (Zeiss). IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h in a water bath. Microvacuole (MV) density and size (Miyata grading) were documented and calculated using an image analysis program. Results The mean glistening density [MV/mm2] and mean Miyata grading (in brackets) were: Vivinex: 11.6 ± 5.7 (0), SN60WF: 264.4 ± 110.3 (2.6), Tecnis: 6.0 ± 2.8 (0), Avansee: 2.2 ± 0.7 (0), Aktis: 851.4 ± 59.4 (3+) and CT Lucia: 71.0 ± 71.6 (1). Conclusions While all tested IOLs showed glistenings with the accelerated laboratory method, the Aktis and SN60WF showed the highest microvacuole density, followed by the CT Lucia. In comparison, the Vivinex, Tecnis, and Avansee IOLs showed far fewer number of glistenings.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany.
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Patrick Merz
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University, Seoul, South Korea
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| |
Collapse
|
4
|
Fișuș AD, Hirnschall ND, Maedel S, Fichtenbaum M, Draschl P, Findl O. Capsular bag performance of a novel hydrophobic acrylic single-piece intraocular lens: Two-year results of a randomised controlled trial. Eur J Ophthalmol 2020; 31:2377-2382. [PMID: 32993380 DOI: 10.1177/1120672120960591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To determine the visual outcome, intraocular lens (IOL) stability and posterior capsule opacification (PCO) rate of a hydrophobic acrylic intraocular lens. SETTING Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN This double-masked randomised study included patients who underwent standard cataract surgery. METHOD Patients received either the hydrophobic acrylic IOL (iPure, PhysIOL) or the hydrophobic acrylic control IOL (Tecnis ZCB00, Johnson&Johnson). Subjective refraction, uncorrected and corrected distance visual acuity (UDVA, CDVA), IOL tilt and decentration (Purkinje meter) and PCO intensity using retroillumination images with automated image analysis (automated quantification of after-cataract, AQUA), were evaluated for both groups 2 years after surgery. RESULTS A total number of 31 patients completed the 2-year follow-up, 16 in the study group and 15 in the control group. The CDVA was 0.0 logMAR (standard deviation - SD: 0.1) for the study IOL and 0.1 logMAR (SD: 0.2) for the control IOL, p = 0.001. The AQUA PCO score for the study group was 2.1 and 1.4 for the control group, p = 0.44. Mean IOL tilt was 2.9° (SD: 1.8) in the study group and 5.0° (SD: 4.5) in the control group, whilst the mean decentration was 0.37 mm (SD: 0.18) and 0.45 mm (SD: 0.3), p = 0.610. CONCLUSION The studied parameters revealed a good performance for both IOLs. Both IOLs had good CDVA, a small amount of tilt and decentration and none of the patients required laser capsulotomies during the follow-up time of 2 years after surgery.Presented at the 37th ESCRS Congress Paris, France, September 2019.
Collapse
Affiliation(s)
- Andreea D Fișuș
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Nino D Hirnschall
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Sophie Maedel
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Maria Fichtenbaum
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Petra Draschl
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Oliver Findl
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| |
Collapse
|
5
|
Koch CR, Santhiago MR, Jorge PA, Sena P, Kara-Júnior N. Posterior Capsule Opacification after Cataract Surgery in Children Over Five Years of Age with Square-edge Hydrophobic versus Hydrophilic Acrylic Intraocular Lenses: A Prospective Randomized Study. Clinics (Sao Paulo) 2020; 75:e1604. [PMID: 32401967 PMCID: PMC7196726 DOI: 10.6061/clinics/2020/e1604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 01/29/2020] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVE To compare the effects of hydrophobic and hydrophilic materials in square-edged acrylic intraocular lenses (IOLs) on the development of posterior capsule opacification (PCO) after pediatric cataract surgery. METHODS Patients were randomly assigned to group 1 (hydrophobic acrylic square-edged IOLs; 13 eyes) or group 2 (hydrophilic acrylic square-edged IOLs; 13 eyes). The study evaluated PCO rates using Evaluation of Posterior Capsule Opacification (EPCO) 2000 software at one, three, six and 12 months postoperatively. Postoperative measurements also included corrected distance visual acuity (CDVA), neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy and postoperative complications other than PCO. RESULTS Both groups had significant increases in PCO rates after one year. Comparison of the groups showed no significant differences in the EPCO scores at three (group 1, 0.007±0.016 vs group 2, 0.008±0.014; p=0.830), six (group 1, 0.062±0.103 vs group 2, 0.021±0.023; p=0.184), or twelve months postoperatively (group 1, 0.200±0.193 vs group 2, 0.192±0.138; p=0.902). We also found no significant group differences regarding the change (delta, Δ) in EPCO scores between three and six months (group 1, 0.055±0.09 vs group 2, 0.013±0.02; p=0.113) or between six and twelve months postoperatively (group 1, 0.139±0.14 vs group 2, 0.171±0.14; p=0.567). Twenty-three percent of patients required Nd:YAG capsulotomy at the twelve-month visit. CONCLUSIONS No differences in PCO rates were found between hydrophobic and hydrophilic acrylic square-edged IOLs in children between five and twelve years of age at one year of follow-up.
Collapse
Affiliation(s)
- Camila Ribeiro Koch
- Departamento de Oftalmologia, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
- Hospital Humberto Castro Lima, Salvador, BA, BR
- Corresponding author. E-mail:
| | - Marcony R Santhiago
- Departamento de Oftalmologia, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
- University of Southern California Roski Eye Institute, Los Angeles, CA, USA
- Departamento de Oftalmologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, BR
| | - Priscilla A Jorge
- Departamento de Oftalmologia, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Paulo Sena
- Hospital Humberto Castro Lima, Salvador, BA, BR
| | - Newton Kara-Júnior
- Departamento de Oftalmologia, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| |
Collapse
|
6
|
Intraindividual comparison of capsule behavior of 2 hydrophobic acrylic intraocular lenses during a 5-year follow-up. J Cataract Refract Surg 2019; 43:228-233. [PMID: 28366371 DOI: 10.1016/j.jcrs.2016.12.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 11/27/2016] [Accepted: 12/02/2016] [Indexed: 11/22/2022]
Abstract
PURPOSE To evaluate and compare the 5-year postoperative anterior (ACO) and posterior capsule opacification (PCO), the occurrence of glistenings, and the level of anterior capsule retraction after implantation of 2 designs of 1-piece hydrophobic acrylic IOLs. SETTING Hospital St. John, Vienna, Austria. DESIGN Randomized controlled prospective case series. METHODS Patients had an Acrysof SA60AT IOL (Group A) implanted in 1 eye and a Tecnis ZCB00 IOL (Group B) implanted in the fellow eye. At 1, 3, and 5 years, the PCO level was evaluated with the Evaluation of Posterior Capsule Opacification software. The level of ACO and capsule retraction was graded subjectively. Glistenings were scored as present or not present. RESULTS Fifty eyes of 25 patients were evaluated after 5 years. No significant differences in PCO scores were found between the 2 groups at all follow-up visits (1 year: 0.06 ± 0.12 [SD] versus 0.07 ± 0.13, P = .35; 3 years: 0.23 ± 0.36 versus 0.22 ± 0.32, P = .66; 5 years: 0.36 ± 0.41 versus 0.36 ± 0.54, P = .98). A significant increase in PCO score was found between 3 and 5 years (P < .01). Anterior capsule opacification was present in Group A and Group B in 18.0% and 2.7% of eyes (P = .03), in 92.0% and 24.0% of eyes, and in 100% and 52% of eyes (P < .01) at 1, 3, and 5 years, respectively. Glistenings (5 years 100%) were observed in Group A. CONCLUSION Both IOLs had a comparable PCO rate 5 years after surgery, although more ACO and retraction as well as glistenings were observed in Group A.
Collapse
|
7
|
Mastromonaco C, Balazsi M, Zoroquiain P, Esposito E, Coblentz J, Logan P, Burnier MN. Removing Subjective Post-Mortem Grading from Posterior Capsular Opacification: A New Automated Detector Opacification Software, ADOS. Curr Eye Res 2018; 43:1362-1368. [DOI: 10.1080/02713683.2018.1501071] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
- Christina Mastromonaco
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
| | | | - Pablo Zoroquiain
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
| | - Evangelina Esposito
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
| | - Jacqueline Coblentz
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
| | - Patrick Logan
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
| | - Miguel N. Burnier
- Ocular Pathology Laboratory- Department of Pathology, The MUHC-McGill University, Montreal, Quebec, Canada
- Department of Ophthalmology, MUHC-McGill University, Montreal, Quebec, Canada
| |
Collapse
|
8
|
Von Tress M, Marotta JS, Lane SS, Sarangapani R. A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials. Clin Ophthalmol 2018; 12:1125-1136. [PMID: 29950808 PMCID: PMC6018849 DOI: 10.2147/opth.s161380] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of this study is to estimate and compare neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomy rates for AcrySof ® and Clareon® intraocular lens (IOL) materials using historical data from the medical literature and Alcon-sponsored clinical studies. Methods Clinical trials that involved the implantation of AcrySof or Clareon monofocal IOLs in subjects with cataract or presbyopia were extracted from the literature and a company repository of clinical studies. The study duration, number of eyes, and cumulative percent of Nd:YAGs for posterior capsule opacification were extracted. Bayesian random effects meta-analyses were conducted to estimate and compare outcomes for the 2 different IOL materials. Results A Bayesian random effects, meta-analysis was performed that combined a literature review of published AcrySof Nd:YAG posterior capsulotomy rates and Nd:YAG rates observed in Alcon-sponsored clinical studies of AcrySof and Clareon. Sixteen Alcon studies contained Nd:YAG data suitable for meta-analysis. Three of these Alcon studies contained results for the Clareon material (2 one-year studies, and 1 three-year study). The literature review included 50 papers from 1998 to 2015. In combination, 30,891 eyes were available for analysis and 2040 Nd:YAG procedures were reported in studies with a follow-up duration ranging in length from 4 months to 10 years. The overall probability of performing a Nd:YAG capsulotomy within a year of implant for AcrySof was 1.44% (1.11% to 1.83%) and 0.62% (0.21% to 1.38%) for Clareon. There was small improvement in the probability of Nd:YAG within a year of implant for Clareon lenses of about 0.82% with a 95% credible interval of (0.07% to 1.36%) at 1 year. Results were similar for incidence rates per 100 surgeries in a year: 0.62 (0.21 to 1.40) for Clareon, 1.46 (1.12 to 1.87) for AcrySof, and the difference was 0.84 (0.07 to 1.39) favoring Clareon. At 3 years, the overall probability of performing a Nd:YAG capsulotomy for AcrySof was 4.19% (3.24% to 5.30%) compared with only 1.82% (0.63% to 4.02%) for Clareon. Conclusion A meta-analysis of Clareon multi-piece and single-piece clinical data predicts that the cumulative Clareon Nd:YAG probability will be ≤ AcrySof by 2.37% (0.18% to 3.91%) at 3 years. The results indicate that Clareon is likely to perform as well as, and possibly better than, AcrySof in terms of Nd:YAG capsulotomy rates.
Collapse
Affiliation(s)
| | | | - Stephen S Lane
- Global Clinical Strategy, Alcon Laboratories, Fort Worth, TX, USA
| | | |
Collapse
|
9
|
Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study. Eye (Lond) 2018; 32:1579-1589. [PMID: 29891902 PMCID: PMC6189124 DOI: 10.1038/s41433-018-0131-2] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 02/09/2018] [Accepted: 05/03/2018] [Indexed: 11/13/2022] Open
Abstract
Purpose To evaluate 3-year incidence of Nd:YAG capsulotomy and PCO and compare the effect of different IOL materials. Methods Data were retrospectively collected from seven UK ophthalmology clinics using Medisoft electronic medical records. Eyes from patients ≥65 years undergoing cataract surgery with implantation of acrylic monofocal IOLs during 2010–2013 and 3-year follow-up were analysed. Nd:YAG capsulotomy and PCO incidence proportions were reported for 3 IOL cohorts: AcrySof, other hydrophobic and hydrophilic acrylic IOLs. Unadjusted/adjusted odds ratios (OR) of Nd:YAG capsulotomy were calculated through logistic regression for non-AcrySof cohorts versus AcrySof. A sub-group analysis in single-piece IOLs (>90% of sample eyes) was also performed. Results The AcrySof cohort included 13,329 eyes, non-AcrySof hydrophobic 19,025 and non-AcrySof hydrophilic 19,808. The 3-year Nd:YAG capsulotomy incidence (95% CI) for AcrySof (2.4%, 2.2–2.7%) was approximately two times lower than non-AcrySof hydrophobic IOLs (4.4%, 4.1–4.7%) and approximately fourfold lower than non-AcrySof hydrophilic IOLs (10.9%, 10.5–11.3%). Trends were similar in PCO incidence (AcrySof: 4.7%; non-AcrySof hydrophobic: 6.3%; non-AcrySof hydrophilic: 14.8%). Also in the analysis restricted to single-piece IOLs, the pattern remained (2.4% vs 5.1% vs. 10.9%, respectively). Adjusted regression analysis showed a approximately two and fivefold increased odds of Nd:YAG for non-AcrySof hydrophobic and hydrophilic acrylic IOLs respectively vs. AcrySof IOLs. Nd:YAG capsulotomy ORs were similar and remained statistically significant in the single-piece IOL sub-group. Conclusions Real-world evidence shows that within 3 years following implantation, AcrySof IOLs are significantly superior in reducing Nd:YAG capsulotomy and PCO incidence compared to other hydrophilic and hydrophobic acrylic IOLs.
Collapse
|
10
|
Biomaterial Influence on Intraocular Lens Performance: An Overview. J Ophthalmol 2018; 2018:2687385. [PMID: 29736282 PMCID: PMC5874989 DOI: 10.1155/2018/2687385] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 12/08/2017] [Accepted: 01/02/2018] [Indexed: 11/18/2022] Open
Abstract
There is strong evidence that the IOL material is the factor having the greatest impact on posterior capsule opacification (PCO), anterior capsule opacification (ACO) development, and glistening formation after cataract surgery, even though there are other IOL features—such as haptic material and design and edge and optic design—that also have some influence. We reviewed the published literature describing the adverse events that are mainly related to the intraocular lens (IOL) material, such as PCO, ACO, and the subsequent capsule contraction, as well as glistening formation. The adverse events presented in this overview are the most common ones in clinical practice, and therefore, they are generally included in the clinical protocols for IOL evaluation.
Collapse
|
11
|
Johansson B. Glistenings, anterior/posterior capsular opacification and incidence of Nd:YAG laser treatments with two aspheric hydrophobic acrylic intraocular lenses - a long-term intra-individual study. Acta Ophthalmol 2017; 95:671-677. [PMID: 28371401 DOI: 10.1111/aos.13444] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 02/20/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare two hydrophobic acrylic intraocular lenses (IOLs) regarding long-term anterior/posterior capsular opacification (ACO/PCO) development and need for neodymium:Yttrium-Aluminum-Garnet (Nd:YAG) laser treatment due to visually disturbing PCO, and to study development of glistenings in the IOL materials. METHODS In a prospective, randomized, intra-individual, comparative trial, 50 cataract patients received either an AcrySof IQ® SN60WF (Alcon, Fort Worth, TX, USA) or a Tecnis® ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA) IOL in the first operated eye, and the second eye received the IOL type not implanted in the first eye. Anterior/posterior capsular opacification (ACO/PCO) and fibrosis were monitored with slit-lamp photography and semi-automated digital analysis 2 and 3 years postoperatively. Glistenings were semi-quantitatively assessed in slit-lamp photographs. Nd:YAG laser treatment for visually disturbing PCO was monitored. RESULTS Visual outcomes were similar for the two IOLs. Anterior capsular fibrosis and/or opacification developed more often in SN60WF eyes. Mean PCO area percentage was larger in ZCB00 eyes 3 years after surgery, but severity score did not differ with statistical significance between the two IOLs. Six ZCB00 eyes and 2 SN60WF eyes underwent Nd:YAG laser treatment during a mean of 4 years 8 months after surgery. This difference was not statistically significant. A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings. CONCLUSION Visual outcomes, PCO development over time and need for Nd:YAG laser treatment were similar for the two IOLs. Anterior capsule fibrosis/contraction and glistenings were more pronounced with the SN60WF IOL.
Collapse
Affiliation(s)
- Björn Johansson
- Department of Ophthalmology; Linköping University; Linköping Sweden
- Department of Clinical and Experimental Medicine; Linköping University; Linköping Sweden
| |
Collapse
|
12
|
Straylight from glistenings in intraocular lenses: In vitro study. J Cataract Refract Surg 2017; 43:102-108. [DOI: 10.1016/j.jcrs.2016.10.027] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 10/20/2016] [Accepted: 10/20/2016] [Indexed: 11/15/2022]
|
13
|
Gosling DB, Chan TKJ. Early clinical experience with a new preloaded one-piece intraocular lens in paediatric cataract surgery. Eye (Lond) 2016; 30:1266-7. [PMID: 27315347 DOI: 10.1038/eye.2016.123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Accepted: 04/08/2016] [Indexed: 11/09/2022] Open
Abstract
PurposeTo report the clinical experience of using the Tecnis PCB00 (Abbott Medical Optics, Santa Ana, CA, USA) preloaded one-piece intraocular lens (IOL) in the setting of a tertiary referral centre for paediatric cataract.MethodsA retrospective case note review of all paediatric cataract surgeries using the Tecnis PCB00 IOL, at a single UK paediatric ophthalmology department.ResultsNine eyes in seven patients received the IOL between December 2014 and January 2016. All patients underwent lens aspiration and insertion of the IOL 'in the bag.' The indications for surgery included developmental cataract (8/9) and traumatic cataract (1/9). Mean age at the time of surgery was 7 years (range 2-14). The median improvement in logMAR best-corrected visual acuity was 0.475 (range 0.250-1.500). The mean follow-up duration was 5 months (range 1-13). No operative or post-operative complications occurred as a result of using the device.ConclusionThe Tecnis PCB00 preloaded IOL appears to be a safe and effective device in treating paediatric cataract.
Collapse
Affiliation(s)
- D B Gosling
- Department of Ophthalmology, Sheffield Children's Hospital, Sheffield, UK
| | - T K J Chan
- Department of Ophthalmology, Sheffield Children's Hospital, Sheffield, UK
| |
Collapse
|