Li H, Yang S, Cao D, Wang Q, Zhang S, Zhou Y, Liu D, Yang R, Cui L, Zhu Z. A new double-antigen sandwich test based on the light-initiated chemiluminescent assay for detecting anti-hepatitis C virus antibodies with high sensitivity and specificity. Front Cell Infect Microbiol 2023; 13:1222778. [PMID: 38076452 PMCID: PMC10704264 DOI: 10.3389/fcimb.2023.1222778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 10/20/2023] [Indexed: 12/18/2023] Open
Abstract
Objectives The aim of this study was to evaluate the performance of a new double-antigen sandwich test that is based on the light-initiated chemiluminescent assay (LiCA®) for detecting anti-hepatitis C virus antibodies (anti-HCV) in comparison to Architect®. Methods Analytical characteristics and diagnostic performance were tested using seroconversion panels and large pools of clinical samples. Positive results were validated by the strip immunoblot assay (RIBA) and HCV RNA. Results Repeatability and within-lab imprecision of LiCA® anti-HCV were 1.31%-3.27%. The C5-C95 interval was -5.44%-5.03% away from C50. LiCA® detected seroconversion in an average of 28.9 days and showed a mean of 3.7 (p = 0.0056) days earlier than Architect®. In a pool of 239 samples with known HCV genotypes 1 to 6, both assays correctly detected all subjects. In 16,305 clinical patient sera, LiCA® detected 4 false-negative (0.25‰) and 14 false-positive (0.86‰) anti-HCV cases, while Architect® recorded 6 false-negative (0.37‰) and 138 false-positive (8.46‰) subjects, respectively. Compared to Architect®, LiCA® presented a significantly better performance in specificity (99.91% vs. 99.14%, n = 16,018, p < 0.0001), positive predictive value (95.29% vs. 67.06%, n = 419, p < 0.0001), and overall accuracy (99.89% vs. 99.12%, n = 16,305, p < 0.0001), while no significant difference in sensitivity (98.61% vs. 97.91%, n = 287, p = 0.5217) and negative predictive value (99.98% vs. 99.96%, n = 15,886, p = 0.3021) was seen. An S/Co value of 3.28 was predicted to be the threshold with a positivity ≥95% for the LiCA® anti-HCV assay. Conclusion LiCA® anti-HCV is a precise and fully automatic chemiluminescent assay with superior sensitivity and specificity. The assay can be used as a valuable tool to supplement the diagnosis of HCV infection.
Collapse
Affiliation(s)
- Haicong Li
- Department of Laboratory Medicine, Shanghai Public Health Clinical Center, Shanghai, China
| | - Shuo Yang
- Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China
| | - Dan Cao
- Department of Laboratory Medicine, Shanghai Public Health Clinical Center, Shanghai, China
| | - Qianying Wang
- Department of Laboratory Medicine, Shanghai Public Health Clinical Center, Shanghai, China
| | - Siyu Zhang
- Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China
| | - Yi Zhou
- Department of Laboratory Medicine, Shanghai Public Health Clinical Center, Shanghai, China
| | - Di Liu
- Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China
| | - Ruifeng Yang
- Peking University People’s Hospital, Peking University Hepatology Institute, Beijing, China
| | - Liyan Cui
- Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China
| | - Zhaoqin Zhu
- Department of Laboratory Medicine, Shanghai Public Health Clinical Center, Shanghai, China
| |
Collapse
|
2
|
Li T, Zhang H, Fang Z, Yin J, Rao W. Clinical performance of the MAGLUMI Anti-HCV (CLIA) Test for detection of hepatitis C virus antibodies. J Virol Methods 2023; 319:114770. [PMID: 37419419 DOI: 10.1016/j.jviromet.2023.114770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 06/30/2023] [Accepted: 07/04/2023] [Indexed: 07/09/2023]
Abstract
BACKGROUND Hepatitis C virus (HCV) infection screening and diagnosis are critical to control the hepatitis C epidemic. Testing for anti-HCV antibodies (Ab) in blood samples is the first step to screen people who have been infected with the virus. OBJECTIVES To evaluate the performance of the MAGLUMI Anti-HCV (CLIA) Test for detection of HCV antibodies. STUDY DESIGN To assess the diagnostic specificity, serum samples from 5053 unselected donors and 205 blood specimens from hospitalized patients were collected. To evaluate the diagnostic sensitivity, 400 positive HCV Ab samples were collected and 30 seroconversion panels were tested. All samples that met the test criteria were tested with the MAGLUMI Anti-HCV (CLIA) Test according to manufacturer's instruction. Results of the MAGLUMI Anti-HCV (CLIA) Test were compared with the Abbott ARCHITECT anti-HCV reference test. RESULTS The specificity of the MAGLUMI Anti-HCV (CLIA) Test was 99.75% and 100.00% in blood donor and hospitalized patient samples, respectively. The sensitivity of the Test in HCV Ab positive samples was 100.00%. Seroconversion sensitivity was comparable between the MAGLUMI Anti-HCV (CLIA) Test and the reference assay. CONCLUSIONS The performance of the MAGLUMI Anti-HCV (CLIA) Test makes it suited for HCV infection diagnosis.
Collapse
Affiliation(s)
- Tinghua Li
- Research & Development Department, Shenzhen New Industries Biomedical Engineering Co., Ltd., Shenzhen, PR China
| | - Hongwei Zhang
- Research & Development Department, Shenzhen New Industries Biomedical Engineering Co., Ltd., Shenzhen, PR China
| | - Zhonggang Fang
- Research & Development Department, Shenzhen New Industries Biomedical Engineering Co., Ltd., Shenzhen, PR China
| | - Jun Yin
- Research & Development Department, Shenzhen New Industries Biomedical Engineering Co., Ltd., Shenzhen, PR China
| | - Wei Rao
- Research & Development Department, Shenzhen New Industries Biomedical Engineering Co., Ltd., Shenzhen, PR China.
| |
Collapse
|
3
|
Sharma S, Thomas E, Caputi M, Asghar W. RT-LAMP-Based Molecular Diagnostic Set-Up for Rapid Hepatitis C Virus Testing. BIOSENSORS 2022; 12:298. [PMID: 35624599 PMCID: PMC9138684 DOI: 10.3390/bios12050298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/23/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
Hepatitis C virus (HCV) infections occur in approximately 3% of the world population. The development of an enhanced and extensive-scale screening is required to accomplish the World Health Organization's (WHO) goal of eliminating HCV as a public health problem by 2030. However, standard testing methods are time-consuming, expensive, and challenging to deploy in remote and underdeveloped areas. Therefore, a cost-effective, rapid, and accurate point-of-care (POC) diagnostic test is needed to properly manage the disease and reduce the economic burden caused by high case numbers. Herein, we present a fully automated reverse-transcription loop-mediated isothermal amplification (RT-LAMP)-based molecular diagnostic set-up for rapid HCV detection. The set-up consists of an automated disposable microfluidic chip, a small surface heater, and a reusable magnetic actuation platform. The microfluidic chip contains multiple chambers in which the plasma sample is processed. The system utilizes SYBR green dye to detect the amplification product with the naked eye. The efficiency of the microfluidic chip was tested with human plasma samples spiked with HCV virions, and the limit of detection observed was 500 virions/mL within 45 min. The entire virus detection process was executed inside a uniquely designed, inexpensive, disposable, and self-driven microfluidic chip with high sensitivity and specificity.
Collapse
Affiliation(s)
- Sandhya Sharma
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA;
- Asghar-Lab: Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA
| | - Emmanuel Thomas
- Department of Microbiology and Immunology and Sylvester Comprehensive Cancer Center, University of Miami School of Medicine, Miami, FL 33136, USA;
| | - Massimo Caputi
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL 33431, USA;
| | - Waseem Asghar
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA;
- Asghar-Lab: Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431, USA
| |
Collapse
|
4
|
Dotters-Katz SK, Kuller JA, Hughes BL. Society for Maternal-Fetal Medicine Consult Series #56: Hepatitis C in pregnancy-updated guidelines: Replaces Consult Number 43, November 2017. Am J Obstet Gynecol 2021; 225:B8-B18. [PMID: 34116035 DOI: 10.1016/j.ajog.2021.06.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
In the United States, it is estimated that 1% to 4% of pregnant women are infected with hepatitis C virus, which carries approximately a 5% risk of transmission from mother to infant. Hepatitis C virus can be transmitted to the infant in utero or during the peripartum period, and infection during pregnancy is associated with an increased risk of adverse fetal outcomes, including fetal growth restriction and low birthweight. The purpose of this document is to discuss the current evidence, provide updated recommendations regarding screening, review treatment, and address management of hepatitis C virus during pregnancy. The following are the Society for Maternal-Fetal Medicine's recommendations: (1) We suggest that third trimester assessment of fetal growth may be performed, but antenatal testing is not indicated in the setting of hepatitis C virus diagnosis alone (GRADE 2C); (2) we suggest screening for viral hepatitis in patients with a diagnosis of intrahepatic cholestasis of pregnancy at an early gestational age or with high levels of bile acids (GRADE 2C); (3) we recommend that obstetrical providers screen all pregnant patients for hepatitis C virus by testing for anti-hepatitis C virus antibodies in every pregnancy (GRADE 1B); (4) we suggest that obstetrical care providers screen hepatitis C virus-positive pregnant patients for other sexually transmitted infections (if not done previously), including human immunodeficiency virus, syphilis, gonorrhea, chlamydia, and hepatitis B virus (GRADE 2C); (5) we recommend vaccination against hepatitis A and B viruses (if not immune) for patients with hepatitis C virus (GRADE 1B); (6) we recommend that direct-acting antiviral regimens only be initiated in the setting of a clinical trial during pregnancy and that people who become pregnant while taking a direct-acting antiviral should be counseled in a shared decision-making framework about the risks and benefits of continuation (GRADE 1C); (7) we suggest that if prenatal diagnostic testing is requested, patients are counseled that data regarding the risk of vertical transmission are reassuring but limited (GRADE 2C); (8) we recommend against cesarean delivery solely for the indication of hepatitis C virus (GRADE 1B); (9) we suggest that obstetrical care providers avoid internal fetal monitors and early artificial rupture of membranes when managing labor in patients with hepatitis C virus unless necessary in the course of management (ie, when unable to trace the fetal heart rate with external monitors and the alternative is proceeding with cesarean delivery) (GRADE 2B); (10) we recommend that hepatitis C virus status not alter standard breastfeeding counseling and recommendations unless nipples are cracked or bleeding (GRADE 1A).
Collapse
Affiliation(s)
| | - Jeffrey A Kuller
- Society for Maternal-Fetal Medicine, 409 12 St. SW, Washington, DC 20024, USA.
| | - Brenna L Hughes
- Society for Maternal-Fetal Medicine, 409 12 St. SW, Washington, DC 20024, USA.
| |
Collapse
|
5
|
Jiang X, Chang L, Yan Y, Ji H, Sun H, Guo F, Wang L. A study based on four immunoassays: Hepatitis C virus antibody against different antigens may have unequal contributions to detection. Virol J 2021; 18:137. [PMID: 34217305 PMCID: PMC8255013 DOI: 10.1186/s12985-021-01608-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 06/23/2021] [Indexed: 12/19/2022] Open
Abstract
Background All commercial Hepatitis C virus antibody (anti-HCV) assays use a combination of recombinant antigens to detect antibody response. Antibody responses to individual antigenic regions (core, NS3/4 and NS5) used in assays have not been investigated. Methods In this study, we quantified HCV viral load, tested anti-HCV with four commercial assays (Ortho-ELISA, Murex-ELISA, Architect-CMIA and Elecsys-ECLIA) in 682 plasma specimens. In antigenic region ELISA platform, microwells were coated with three antigens: core (c22-3), NS3/4 (c200) and NS5 individually. The signal-to-cutoff (S/Co) values of different assays, and antibody responses to individual antigens were compared. The specimens were divided into HCV RNA positive group, anti-HCV consistent group, and anti-HCV discrepant group. Results Anti-core and anti-NS3/4 were simultaneously detected in 99.2% of HCV RNA positive specimens and showed great consistency with total anti-HCV signals. Responses to the core region were more robust than those to the NS3/4 region in anti-HCV consistent group (p < 0.001). Anti-NS5 only occurred in companying with responses to the core and NS3/4 antigens, and failed to affect the final anti-HCV positive signals. In anti-HCV discrepant group, 39.0% of positive signals could not be traced back to any single antigenic region. Conclusion Antibody responses to the core and NS3/4 antigens were stronger, whereas responses to the NS5 antigen were the weakest, indicating that individual antigenic regions played different roles in total anti-HCV signals. This study provides an impetus for optimizing commercial anti-HCV assays. Supplementary Information The online version contains supplementary material available at 10.1186/s12985-021-01608-x.
Collapse
Affiliation(s)
- Xinyi Jiang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, People's Republic of China
| | - Le Chang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China
| | - Ying Yan
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China
| | - Huimin Ji
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, People's Republic of China
| | - Huizhen Sun
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, People's Republic of China
| | - Fei Guo
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China
| | - Lunan Wang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Dahua Road, Beijing, 100730, People's Republic of China. .,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, People's Republic of China. .,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, People's Republic of China.
| |
Collapse
|
6
|
Morgan TR. Hepatitis C Guidance 2019 Update: American Association for the Study of Liver Diseases-Infectious Diseases Society of America Recommendations for Testing, Managing, and Treating Hepatitis C Virus Infection. Hepatology 2020; 71:686-721. [PMID: 31816111 PMCID: PMC9710295 DOI: 10.1002/hep.31060] [Citation(s) in RCA: 470] [Impact Index Per Article: 117.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 11/21/2019] [Indexed: 02/06/2023]
Affiliation(s)
| | - Timothy R. Morgan
- Chief of Hepatology Veterans Affairs Long Beach Healthcare System Long Beach CA
| | | |
Collapse
|
7
|
Summa KC, Maddur H. Hepatitis C Antibody Positive, RNA Negative. Clin Liver Dis (Hoboken) 2019; 14:5-7. [PMID: 31391928 PMCID: PMC6677011 DOI: 10.1002/cld.755] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Accepted: 08/11/2018] [Indexed: 02/04/2023] Open
Affiliation(s)
- Keith C. Summa
- Department of MedicineNorthwestern University Feinberg School of MedicineChicagoIL,Division of Gastroenterology and HepatologyNorthwestern University Feinberg School of MedicineChicagoIL
| | - Haripriya Maddur
- Department of MedicineNorthwestern University Feinberg School of MedicineChicagoIL,Division of Gastroenterology and HepatologyNorthwestern University Feinberg School of MedicineChicagoIL
| |
Collapse
|
8
|
Puchades Renau L, Berenguer M. Introduction to hepatitis C virus infection: Overview and history of hepatitis C virus therapies. Hemodial Int 2018; 22 Suppl 1:S8-S21. [DOI: 10.1111/hdi.12647] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Lorena Puchades Renau
- Department of Gastroenterology, Hepatology Unit & Instituto de Investigación La Fe; Hospital Universitari i Politècnic La Fe; Valencia Spain
| | - Marina Berenguer
- Department of Gastroenterology, Hepatology Unit & Instituto de Investigación La Fe; Hospital Universitari i Politècnic La Fe; Valencia Spain
- Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd); Valencia Spain
- School of Medicine; University of Valencia; Valencia Spain
| |
Collapse
|
9
|
Valoración de sueros con bajo índice S/CO utilizando 2 sistemas de quimioluminiscencia para la detección de anticuerpos frente al virus de la hepatitis C y su correlación con la detección de ARN viral. Enferm Infecc Microbiol Clin 2018; 36:222-224. [DOI: 10.1016/j.eimc.2016.12.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 12/19/2016] [Accepted: 12/22/2016] [Indexed: 11/21/2022]
|
10
|
Fletcher GJ, Raghavendran A, Sivakumar J, Samuel P, Abraham P. Diagnostic reliability of Architect anti-HCV assay: Experience of a tertiary care hospital in India. J Clin Lab Anal 2017; 32. [PMID: 28657153 DOI: 10.1002/jcla.22245] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Accepted: 03/28/2017] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND & AIMS Anti-HCV assays are prone to false positive results. Thus, accurate detection of HCV infection is critical for the timely therapeutic management. This study ascertained the reliability of Architect anti-HCV assay (Abbott) and to estimate the agreement of this assay with Ortho HCV 3.0 ELISA Test System with Enhanced SAVe (Ortho), HCV Tri-dot (Tri-dot) and HCV-PCR in a tertiary care setting. METHODS A total of 78 788 consecutive sera were routinely screened for anti-HCV antibodies using Architect. All repeatedly reactive anti-HCV sera (n=1000) and anti-HCV negative sera (n=300) were tested in Ortho and in Tri-dot assays. Representative proportions of sera (n=500) with various signal-to-cut-off (S/Co) ratio were also compared with HCV-PCR. RESULTS When Architect was compared with Ortho, Tri-dot, and HCV-PCR, the level of agreement as assessed by kappa were .26, .16, and .27 respectively. Using Latent class analysis (LCA), we found that sensitivity and specificity were 100% and 36.1% for Architect, 93.8% and 100% for Ortho and 63.8% and 100% for Tri-dot respectively. The median S/CO ratio of Architect and Ortho anti-HCV assays were significantly different between HCV-PCR positive and negative results (P<.0001). Furthermore, Architect S/CO ratio of >8 showed higher accuracy indices in both anti-HCV assays. CONCLUSIONS Architect can be used as a screening assay because of its high sensitivity, high throughput, and short turnaround time. However, S/Co ratios of ≥1 to <8 in Architect necessitates HCV PCR to identify current infection and or EIA to distinguish true positivity from false biological positivity.
Collapse
Affiliation(s)
| | | | | | - Prasanna Samuel
- Department of Bio-statistics, Christian Medical College, Vellore, India
| | - Priya Abraham
- Department of Clinical Virology, Christian Medical College, Vellore, India
| |
Collapse
|
11
|
Komitova RT, Atanasova MV, Pavlova TA, Nyagolov MS, Ivanova AV. Diagnostic Dilemmas in Hepatitis C Virus Infection for Hemodialysis Patients. Folia Med (Plovdiv) 2017; 59:70-77. [PMID: 28384106 DOI: 10.1515/folmed-2017-0012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Accepted: 12/20/2016] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Hepatitis C virus (HCV) is a leading cause of chronic hepatitis in dialysis patients. The diagnosis of HCV infection in these patients is predominantly based on laboratory tests because of the specificity of the clinical course of the disease. AIM The present prospective study aimed at determining very accurately the prevalence rate of HCV infection in patients on dialysis by simultaneously testing them for anti-HCV and for HCV RNA levels. MATERIALS AND METHODS For the present cross-sectional longitudinal study we recruited and followed up 93 patients from St George University Hospital Hemodialysis Unit between July 2013 and December 2014. All patients were tested for anti-HCV and HCV RNA. The anti-HCV negative patients were tested for anti-HCV and HCV RNA at least twice at intervals of 6 months or more (up to 12 months). Anti-HCV antibodies were identified using a third generation ELISA assay. Commercial kits for real-time polymerase chain reaction (RT-PCR) were used to detect HCV RNA in the plasma and mononuclear cells. Aminotransferase and gammaglutamyl transpeptidase levels were studied to find if liver inflammation was present. RESULTS The total seroprevalence in 68 patients was 20.6% (14). Of these, 10 patients were viremic (HCV RNA+/anti-HCV+), and 4 patients (5.9%) had discordant results (anti-HCV+/HCV RNA-). Acute hepatitis was detected in one patient. Duration of dialysis in HCV viremic patients was longer than that in aviremic patients (p=0.005). CONCLUSIONS The present study suggests that HCV infection in dialysis patients can be diagnosed more accurately if these patients are tested using two diagnostic methods - a serological test and a biomolecular assay. Further studies with larger sample size may prove the feasibility of such approach for all dialysis patients in this country.
Collapse
Affiliation(s)
- Radka T Komitova
- Department of Infectious Diseases, Parasitology and Tropical Medicine, Faculty of Medicine, Medical University of Plovdiv, 15A Vassil Aprilov Blvd., 4002 Plovdiv, Bulgaria
| | - Maria V Atanasova
- Department of Microbiology and Immunology, Faculty of Pharmacy, Medical University of Plovdiv, Plovdiv
| | | | - Monica Sh Nyagolov
- Clinic of Gastroenterology, Laboratory of Porphyrias and Molecular Diagnostics of Liver Diseases, St Ivan Rilski University Hospital, Sofia
| | - Aneta V Ivanova
- Clinic of Gastroenterology, Laboratory of Porphyrias and Molecular Diagnostics of Liver Diseases, St Ivan Rilski University Hospital, Sofia
| |
Collapse
|
12
|
De Paschale M, Manco MT, Arpino O, Ricucci V, Paganini A, Belvisi L, Cagnin D, Cerulli T, Cianflone A, Agrappi C, Mirri P, Clerici P. Threshold value of LIAISON XL anti-HCV screening assay predicting positive immunoblotting results. J Med Virol 2017; 89:1817-1822. [PMID: 28401710 DOI: 10.1002/jmv.24831] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 04/01/2017] [Indexed: 11/06/2022]
Abstract
Some international guidelines recommend evaluating the need to confirm positive anti-hepatitis C virus (HCV) antibody screening results by means of a more specific antibody or molecular biology test on the basis of a screening threshold value (such as the sample signal/cut-off ratio) that can predict the positivity of additional antibody testing in at least 95% of cases. The aim of this study was to determine the threshold value of the DiaSorin LIAISON XL chemiluminescence test. Two hundred and twenty-eight routine laboratory samples that were chemiluminescence positive for anti-HCV antibodies but had different signal/cut-off ratios were assayed using immunoblotting, which indicated that 155 (68.0%) were positive, 40 (17.5%) were negative, and 33 (14.5%) were indeterminate. When the samples were divided on the basis of their signal/cut-off ratios, 95.5% of the samples with a ratio of ≥3.5 were positive as against 74.1% of the positive or indeterminate samples with a ratio of <3.5. Statistical analysis using Youden's index and a receiver operating characteristic curve showed that the optimum cut-off value was 3.65. These findings indicate that, when using the LIAISON XL system for anti-HCV antibody screening, a signal/cut-off ratio of ≥3.65 makes further confirmatory tests unnecessary.
Collapse
Affiliation(s)
- Massimo De Paschale
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Maria Teresa Manco
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Olivia Arpino
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Valentina Ricucci
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Alessia Paganini
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Luisa Belvisi
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Debora Cagnin
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Teresa Cerulli
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Annalisa Cianflone
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Carlo Agrappi
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Paola Mirri
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| | - Pierangelo Clerici
- Microbiology Unit, ASST Ovest Milanese, Hospital of Legnano, Legnano, Milan, Italy
| |
Collapse
|
13
|
Cadieux G, Campbell J, Dendukuri N. Systematic review of the accuracy of antibody tests used to screen asymptomatic adults for hepatitis C infection. CMAJ Open 2016; 4:E737-E745. [PMID: 28018889 PMCID: PMC5173481 DOI: 10.9778/cmajo.20160084] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Several expert groups, including the United States Preventive Services Task Force and the Canadian Task Force on Preventive Health Care, have recently examined or are currently examining whether primary care physicians should screen asymptomatic adults for hepatitis C virus (HCV) infection. To inform decision-making on HCV screening, we performed a systematic review of the accuracy of antibody tests compared with other immunoassays and RNA detection for screening asymptomatic adults for HCV infection in Canada. METHODS MEDLINE and Embase databases were searched from 1990 to 2016; resulting citations were uploaded into DistillerSR and independently screened by 2 reviewers. Original research studies, systematic reviews and meta-analyses were eligible for inclusion. At least 80% of the study population had to be asymptomatic, nonpregnant, treatment-naïve adults with unknown liver enzyme values and unknown HCV status. Risk of bias was assessed with the use of the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool; the quality of the body of evidence was assessed by means of GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology. RESULTS Of 1537 articles identified, 81 underwent full-text review, and 9 studies met the inclusion criteria. Compared with RNA detection, the sensitivity of the third-generation enzyme-linked immunosorbent assay was variable (61.0%-81.8%), and its specificity was high (97.5%-99.7%). As expected, there were more false-positive results when comparing antibody tests to RNA detection than to other immunoassays. Our GRADE assessment suggested that there was a high concern for risk of bias, particularly verification bias, and substantial inconsistency between studies in terms of their design. INTERPRETATION More research is needed to better characterize the accuracy of antibody tests used to screen for HCV infection in the general population. Jurisdictions that recently adopted birth cohort screening for HCV infection are encouraged to evaluate and report on the accuracy of HCV screening tests and screening benefits and harms. PROSPERO registration: no. CRD42016039710.
Collapse
Affiliation(s)
- Geneviève Cadieux
- Dalla Lana School of Public Health (Cadieux, Campbell), University of Toronto, Toronto, Ont.; Department of Epidemiology, Biostatistics and Occupational Health (Dendukuri), McGill University, Montréal, Que
| | - Jennifer Campbell
- Dalla Lana School of Public Health (Cadieux, Campbell), University of Toronto, Toronto, Ont.; Department of Epidemiology, Biostatistics and Occupational Health (Dendukuri), McGill University, Montréal, Que
| | - Nandini Dendukuri
- Dalla Lana School of Public Health (Cadieux, Campbell), University of Toronto, Toronto, Ont.; Department of Epidemiology, Biostatistics and Occupational Health (Dendukuri), McGill University, Montréal, Que
| |
Collapse
|
14
|
Binder SR, Theel ES. Syphilis testing algorithms: A review. World J Immunol 2016; 6:1-8. [DOI: 10.5411/wji.v6.i1.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 10/02/2015] [Accepted: 11/25/2015] [Indexed: 02/05/2023] Open
Abstract
The methods and strategies used to screen for syphilis and to confirm initially reactive results can vary significantly across clinical laboratories. While the performance characteristics of these different approaches have been evaluated by multiple studies, there is not, as of yet, a single, universally recommended algorithm for syphilis testing. To clarify the currently available options for syphilis testing, this update will summarize the clinical challenges to diagnosis, review the specific performance characteristics of treponemal and non-treponemal tests, and finally, summarize select studies published over the past decade which have evaluated these approaches. Specifically, this review will discuss the traditional and reverse sequence syphilis screening algorithms commonly used in the United States, alongside a discussion of the European Centre for Disease Prevention and Control syphilis algorithm. Ultimately, in the United States, the decision of which algorithm to use is largely dependent on laboratory resources, the local incidence of syphilis and patient demographics.
Collapse
|
15
|
Arora S, Doda V. Role of signal-to-cut-off ratios of anti-hepatitis C virus antibody by enzyme immunoassays along with ID-NAT for screening of whole blood donors in India. Asian J Transfus Sci 2016; 10:75-8. [PMID: 27011676 PMCID: PMC4782500 DOI: 10.4103/0973-6247.165838] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background: The use of elevated signal-to-cut off ratios (S/CO) as an alternate to further supplemental testing (i.e., RIBA) has been included in the guidelines provided by the Centres for Disease Control and Prevention for HCV diagnostic purposes since 2003. With availability of screening by NAT and non availability of RIBA, further confirmation of HCV infection has been possible at the molecular level (RNA). Aims: To study the role of S/CO ratios of anti hepatitis C virus antibody detection by enzyme immunoassays (EIA) along with ID-NAT for screening of whole blood donors. Methods: In this study we reviewed the donor screening status for anti HCV from January 2013 to May 2014. All the donations were screened for anti HCV with fourth generation ELISA (BioRad Monolisa Ag-Ab Ultra) as well as with ID NAT (Procleix Ultrio). The S/CO ratio of all the anti-HCV reactive samples were analysed for their presence of HCV RNA. Results: On screening 21,115 donors for HCV, 83 donors (0.39%) were found reactive on pilot tube and repeat plasma bag testing (S/Co ratio ≥1) by ELISA. 41 donors were HCV RNA reactive with ID-NAT. 4 samples out of 41 were NAT yields and 37 were concordant reactive with ELISA. The S/Co ratio of anti-HCV reactive samples ranged from 0.9-11.1 [mean = 5.1; SD ± 2.9] whereas S/Co ratio of anti HCV and NAT reactive samples (concordant positives) ranged from 4.1-11.1 [mean 7.3]. In our analysis we found that S/CO ratio of 4 showed positive predictive value (PPV) and sensitivity of 100%. Summary/Conclusions: Our study showed that S/CO of 4 for anti HCV on ELISA would have maximum positive predictive value of having donor with HCV RNA. S/CO ratio of 4 is very close to 3.8 which was the CDC guideline. The presence of anti-HCV does not distinguish between current or past infections but a confirmed anti-HCV-positive result indicates the need for counseling and medical evaluation for HCV infection.
Collapse
Affiliation(s)
- Satyam Arora
- Department of Transfusion Medicine, Dr. Ram Manohar Lohia Hospital, New Delhi, India
| | - Veena Doda
- Department of Transfusion Medicine, Dr. Ram Manohar Lohia Hospital, New Delhi, India
| |
Collapse
|
16
|
Zhang K, Wang L, Lin G, Li J. Is Anti-Hepatitis C Virus Antibody Level an Appropriate Marker to Preclude the Need for Supplemental Testing. Intervirology 2016; 58:310-7. [PMID: 26785210 DOI: 10.1159/000441474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Accepted: 10/04/2015] [Indexed: 12/09/2022] Open
Abstract
OBJECTIVES In the present study, we aimed to determine whether signal-to-cutoff (S/Co) ratios of reactive anti-HCV samples could be used as a basis for avoiding the need for supplemental testing in our study population. METHODS We analyzed 901 anti-HCV-positive sera from 8 institutions in China. The Ortho VITROS anti-HCV assay and Monolisa Plus anti-HCV version 2 were used as screening assays to detect anti-HCV antibodies. Recombinant immunoblot assay (RIBA) and quantitative tests for HCV RNA were performed to validate confirmed HCV infection status. RESULTS Receiver operating characteristic curve analyses demonstrated that 41.5% (114/275) of true-positive samples with S/Co ratios ≤3.0 would be missed and the negative predictive value was 63.9 and 87.06%, using real-time polymerase chain reaction (RT-PCR) and RIBA as supplemental testing, respectively. 29.8% (90/302) of those who tested positive by RIBA samples were missed when only RT-PCR was used as supplemental testing. CONCLUSIONS We determined that very low anti-HCV levels (S/Co ≤3.0), as determined by chemiluminescence immunoassay, was not an appropriate marker to preclude the need for supplemental testing in our study population. A screening strategy employing a secondary HCV antibody assay using different HCV antigens from the first assay as the supplemental testing method should be studied further. The immunoblot assay, as a supplemental testing method, is still necessary.
Collapse
Affiliation(s)
- Kuo Zhang
- National Center for Clinical Laboratories, Beijing Hospital, Beijing, PR China
| | | | | | | |
Collapse
|
17
|
Fisher DG, Hess KL, Erlyana E, Reynolds GL, Cummins CA, Alonzo TA. Comparison of Rapid Point-of-Care Tests for Detection of Antibodies to Hepatitis C Virus. Open Forum Infect Dis 2015; 2:ofv101. [PMID: 26269795 PMCID: PMC4531224 DOI: 10.1093/ofid/ofv101] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 07/03/2015] [Indexed: 12/15/2022] Open
Abstract
OraSure had the highest sensitivity at 92.7% followed closely by Chembio's three blood tests. False results were associated with HIV, and hepatitis B core antibody. The OraSure and Chembio blood tests have good performance characteristics. Background. Hepatitis C is one of the most prevalent blood-borne diseases in the United States. Despite the benefits of early screening, among 3.2 million Americans who are infected with hepatitis C virus (HCV), 50%–70% are unaware of their infection status. Methods. Data were collected between 2011 and 2014, from 1048 clients who were in the following groups: (1) injection drug users, (2) women at sexual risk, (3) gay and bisexual men, and (4) transgender individuals. The sensitivity and specificity of point-of-care tests included (1) the MedMira rapid human immunodeficiency virus (HIV)/HCV antibody test, (2) MedMira hepatitis B (HBV)/HIV/HCV antibody test, (3) Chembio HCV Screen Assay used with both whole blood and (4) oral specimens, (5) Chembio HIV-HCV Assay also used with both whole blood and (6) oral specimens, (7) Chembio HIV-HCV-Syphilis Assay, and (8) OraSure HCV Rapid Antibody Test used with whole blood. The gold standard for the HCV tests were HCV enzyme immunoassay (EIA) 2.0. Results. OraSure had the highest sensitivity at 92.7% (95% confidence interval [CI] = 88.8%–96.5%) followed closely by Chembio's 3 blood tests at 92.1% (95% CI = 87.7%–96.4%), 91.5% (95% CI = 87.2%–95.7%), and 92.3% (95% CI = 88.4%–96.2%). The sensitivities of MedMira HIV/HCV and MedMira HIV/HCV/HBV tests were the lowest, at 79.1% (95% CI = 72.6%–85.5%), and 81.5% (95% CI = 75.2%–87.8%), respectively. Specificity for the OraSure was 99.8% (95% CI = 99.4%–100%); specificity for the Chembio blood tests was 99.2% (95% CI = 98.6%–99.9%), 99.4% (95% CI = 98.8%–99.9%), and 99.3% (95% CI = 98.8%–99.9%); and specificity for the MedMira was100% and 100%. False-negative results were associated with HIV and hepatitis B core antibody serostatus. Conclusions. The OraSure and Chembio blood tests (including those multiplexed with HIV and syphilis) appear to good performance characteristics. This study has identified potential limitations of rapid testing in those testing positive for HIV and HBcAb. There should be discussion of updates to the 2013 CDC guidance.
Collapse
Affiliation(s)
- Dennis G Fisher
- Center for Behavioral Research and Services ; Psychology Department
| | | | - Erlyana Erlyana
- Center for Behavioral Research and Services ; Department of Health Care Administration
| | - Grace L Reynolds
- Center for Behavioral Research and Services ; Department of Health Care Administration
| | | | - Todd A Alonzo
- Department of Preventive Medicine , University of Southern California , Los Angeles
| |
Collapse
|
18
|
Zhang K, Wang L, Sun Y, Zhang R, Lin G, Xie J, Li J. Improving the safety of blood transfusion by using a combination of two screening assays for hepatitis C virus. Transfus Med 2014; 24:297-304. [PMID: 25262976 DOI: 10.1111/tme.12152] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Revised: 07/22/2014] [Accepted: 08/19/2014] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND OBJECTIVES To illustrate that the combination of a single nucleic acid amplification test (NAT) with a single immunoassay for hepatitis C virus (HCV) detection, as proposed internationally, may lead to the omission of anti-HCV reactive sera with non-reactive NAT results. MATERIALS AND METHODS In total, 822 of 519, 299 serum samples from 11 blood centres in China were retested for anti-HCV by using 10 screening assays to detect HCV antibodies. A recombinant immunoblot assay (RIBA HCV 3·0; Ortho-Clinical Diagnostics) was performed to define confirmed HCV infection status. Samples with positive or indeterminate RIBA-HCV results were tested by quantitative tests for HCV RNA (Roche Diagnostics). RESULTS We found that 47 of the 822 (5·72%) serum samples were RIBA-positive without detectable HCV RNA. For these samples, the 10 anti-HCV immunoassays gave discordant and unsatisfactory results (detection rate ranging from 10·64 to 34·04%; ratio per 100 000 donations ranging from 5·97 to 8·09). Compared with a single anti-HCV screening assay, the two-assay combination increased the detection of these samples. The five best combinations [Sorin and Lizhu enzyme immunoassays (EIAs), Ortho and Lizhu EIAs, Sorin and Wantai EIAs, Sorin EIA and Roche CIA and Ortho and Wantai EIAs] increased the detection rate from 46·81 to 55·57%, thus reducing the ratio per 100 000 donations of HCV-seropositive samples. CONCLUSION The combination of two anti-HCV screening immunoassays in parallel with an HCV NAT is a better strategy for HCV detection in blood centres to improve the safety of blood transfusion.
Collapse
Affiliation(s)
- K Zhang
- National Center for Clinical Laboratories, Beijing Hospital, Beijing, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|
19
|
Bouare N, Vaira D, Gothot A, Delwaide J, Bontems S, Seidel L, Gerard P, Gerard C. Prevalence of HIV and HCV infections in two populations of Malian women and serological assays performances. World J Hepatol 2012; 4:365-73. [PMID: 23355914 PMCID: PMC3554800 DOI: 10.4254/wjh.v4.i12.365] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2012] [Revised: 10/15/2012] [Accepted: 11/14/2012] [Indexed: 02/06/2023] Open
Abstract
AIM To estimate the prevalence of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) infections in women in Mali and to evaluate the performance of serological assays. METHODS Two prospective studies were conducted in 2009 and 2010 in Mali. They concerned first, 1000 pregnant women attending six reference health centers in Bamako (Malian capital) between May 26 and June 16, 2009; and secondly, 231 women over 50 years who consulted general practitioners of two hospitals in Bamako between October 25 and December 24, 2010. Blood samples were collected and kept frozen in good condition before analysis. All samples depicted as positive using HIV/HCV enzyme immuno-assay screening assays were submitted to confirmation analysis. Molecular markers of HCV were characterized. RESULTS The seroprevalence of HIV and HCV in the population of pregnant women was 4.1% and 0.2% respectively. Among older women the seroprevalence was higher and similar for HIV and HCV (6.1% vs 6.5%). The anti-HIV prevalence was not different in young and older women (4.1% vs 6.1%). In contrast, the anti-HCV prevalence was higher in older compared to younger women (6.5% vs 0.2%, P < 0.01). Of 2 pregnant women who were HCV seropositive, only one was polymerase chain reaction (PCR) reactive and infected by genotype 2, with a viral load of 1600 IU/mL. Regarding older women who were HCV seropositive, 13 out of 15 were PCR reactive, infected by genotype 1 or 2. Globally HCV genotype 2 was predominant. The positive predictive value (PPV) measured with VIKIA HIV test in young women was 100% therefore significantly higher than the 87.5% measured in older women (P < 0.05). Conversely, the PPV measured with Monolisa HCV assay in older women was 88.2% and higher than the 14.3% measured in younger women (P < 0.01). CONCLUSION Whereas HIV prevalence was similar in both subpopulations HCV was more frequent among older women (P < 0.01). The PPV of screening assays varied with the age of the subjects.
Collapse
Affiliation(s)
- Nouhoum Bouare
- Nouhoum Bouare, Dolores Vaira, Andre Gothot, Sebastien Bontems, Christiane Gerard, Department of Hematobiology, Immuno-Hematology and AIDS Reference Laboratory B35, CHU-ULg, 4000 Liege, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Lee SR, Kardos KW, Schiff E, Berne CA, Mounzer K, Banks AT, Tatum HA, Friel TJ, DeMicco MP, Lee WM, Eder SE, Monto A, Yearwood GD, Guillon GB, Kurtz LA, Fischl M, Unangst JL, Kriebel L, Feiss G, Roehler M. Evaluation of a new, rapid test for detecting HCV infection, suitable for use with blood or oral fluid. J Virol Methods 2011; 172:27-31. [DOI: 10.1016/j.jviromet.2010.12.009] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2010] [Revised: 10/08/2010] [Accepted: 12/14/2010] [Indexed: 02/07/2023]
|
21
|
Vermeersch P, Van Ranst M, Lagrou K. Evaluation of the use of a combined HCV antigen/antibody assay in routine laboratory practice. Acta Clin Belg 2010; 65:245-7. [PMID: 20954463 DOI: 10.1179/acb.2010.053] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
BACKGROUND Combined hepatitis C virus (HCV) antigen/antibody (Ag/Ab) assays offer the advantage of a shorter window phase compared to traditional anti-HCV antibody assays. These assays have been extensively evaluated for the screening of healthy blood donors, but not in routine laboratory practice. METHODS We evaluated the performance of the combined HCV Ag/Ab assay Monolisa Ultra and compared it to Monolisa anti-HCV Plus (which only detects anti-HCV antibodies) in 61 HCV RNA-positive patients (genotypes 1 to 5) and in 276 consecutive AxSYM HCV-reactive patients. Discordant sera were tested with immunoblot and PCR. RESULTS All 61 PCR-positive sera were positive with AxSYM, Monolisa Ultra, and Monolisa Plus. Of the 276 consecutive AxSYM-reactive patients, 177 were confirmed as HCV-positive, 78 were HCV-negative and 21 were HCV-indeterminate. There were 4 false-positive results with Monolisa Ultra compared to 1 false-positive result with Monolisa PLus. The signal/cut-off ratio in immunoblot-negative sera was significantly higher with HCV Ultra compared to HCV Plus (p < 0.01). Sensitivity and specificity in AxSYM-reactive sera were 99.4% and 94.9% for Monolisa Ultra and 99.4% and 98.7% for Monolisa Plus. CONCLUSION When used as a secondary test, the sensitivity of the combined HCV Ag/Ab assay Monolisa Ultra was excellent, but specificity was reduced in AxSYM-reactive sera compared to Monolisa Plus.
Collapse
Affiliation(s)
- P Vermeersch
- Laboratoriumgeneeskunde, Universitaire Ziekenhuizen Leuven, Leuven, België
| | | | | |
Collapse
|
22
|
Kiely P, Walker K, Parker S, Cheng A. Analysis of sample-to-cutoff ratios on chemiluminescent immunoassays used for blood donor screening highlights the need for serologic confirmatory testing. Transfusion 2010; 50:1344-51. [PMID: 20113456 DOI: 10.1111/j.1537-2995.2009.02572.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND High sample-to-cutoff (s/co) ratios on hepatitis C virus antibody (anti-HCV) screening immunoassays (IAs) are indicative of confirmed-positive results and, according to some reports, can be used to determine anti-HCV status without the need for confirmatory testing. The purpose of this study was to determine whether s/co ratios on hepatitis B surface antigen (HBsAg), antibody to human immunodeficiency virus Types 1 and 2 (anti-HIV-1/2), anti-HCV, and antibody to human T-lymphotropic virus Types I and II (anti-HTLV-I/II) chemiluminescent immunoassays (ChLIAs) can be used to discriminate between biologic false-reactive (BFR) and confirmed-positive results. STUDY DESIGN AND METHODS In a blood donor population the s/co ratio distributions for BFR and confirmed-positive results were compared for the Abbott PRISM HBsAg, HIV O Plus, HCV, and HTLV-I/II ChLIAs to determine the extent of overlap between the two distributions for each assay. RESULTS The s/co ratio distributions for BFR and confirmed results overlapped in the range of 10.00 to 60.00, 1.00 to 6.00, 3.00 to 15.00, and 1.00 to 100.00 for the PRISM HIV O Plus, HCV, HTLV-I/II, and HBsAg assays, respectively. CONCLUSION Although high s/co ratios were predictive of confirmed-positive results in all four assays, a number of confirmed-positive samples gave low values while some biologic false-positive samples showed high values. As the s/co ratio distributions for BFR and confirmed-positive results overlapped for all four PRISM assays, this study highlights the importance of serologic confirmatory testing and the need for caution when using screening IA results to assign a final donor status.
Collapse
Affiliation(s)
- Philip Kiely
- Infectious Disease Screening Laboratory, Australian Red Cross Blood Service, Melbourne, Brisbane, and Perth, Australia.
| | | | | | | |
Collapse
|
23
|
Kim S, Kim JH, Yoon S, Park YH, Kim HS. Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection. J Clin Microbiol 2008; 46:3919-23. [PMID: 18945839 PMCID: PMC2593301 DOI: 10.1128/jcm.01603-08] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2008] [Revised: 09/13/2008] [Accepted: 10/11/2008] [Indexed: 01/01/2023] Open
Abstract
Various automated chemiluminescence immunoassay (CLIA) analyzers for the detection of antibodies to hepatitis C virus (HCV) are now commercially available in clinical laboratories and are replacing conventional enzyme immunoassays. We investigated the performance of four anti-HCV CLIAs (the Architect Anti-HCV assay on the Architect i2000 system, the Vitros Anti-HCV assay on the Vitros ECiQ Immunodiagnostic System, the Access HCV Ab PLUS assay on the UniCel DxI 800 analyzer, and the newly developed Elecsys Anti-HCV assay on the Cobas e 411 analyzer). The total percent coefficient of variation values of imprecision were 3.5 to 5.7% with positive control materials and 7.2 to 10.2% with negative control materials. The agreement between the results of the Elecsys, Architect, Vitros, and Access CLIAs ranged from 94.5 to 98.1%. The clinical sensitivity of all CLIAs was 100%. Each CLIA showed excellent reproducibility and clinical sensitivity. The Elecsys, Architect, Vitros, and Access CLIAs showed clinical specificities of 98.2, 98.8, 96.5, and 98.2%.
Collapse
Affiliation(s)
- Sinyoung Kim
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seodaemun-gu, Seoul, Korea.
| | | | | | | | | |
Collapse
|
24
|
Establishment of reference values for immunoglobulins in the cryoprecipitate. Clin Immunol 2008; 129:360-4. [DOI: 10.1016/j.clim.2008.07.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2008] [Revised: 07/04/2008] [Accepted: 07/09/2008] [Indexed: 11/20/2022]
|