1
|
Bubonja-Šonje M, Peruč D, Abram M, Mohar-Vitezić B. Prevalence of occult hepatitis B virus infection and characterisation of hepatitis B surface antigen mutants among adults in western Croatia. Ann Hepatol 2024; 29:101156. [PMID: 37758118 DOI: 10.1016/j.aohep.2023.101156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 07/27/2023] [Accepted: 09/11/2023] [Indexed: 10/03/2023]
Abstract
INTRODUCTION AND OBJECTIVES Occult hepatitis B virus (HBV) infection (OBI) is characterised by low levels of hepatitis B virus (HBV) DNA in the blood/liver of patients with negative hepatitis B surface antigen (HBsAg). This study aimed to determine the OBI prevalence and virological characteristics (viral genotypes and HBsAg mutants) in patients with an "anti-HBc only" serological profile. MATERIALS AND METHODS A total of 24 900 serum samples were routinely screened for hepatitis B markers over a five-year period. All anti-HBc-positive/HBsAg-negative/anti-HBs-negative sera were selected and analysed for the presence of HBV DNA. Mutational analyses of the HBs gene and polymerase gene sequences were performed. RESULTS 1749 (7.02%) sera were anti-HBc positive, and 113 (0.45%) sera had an "anti-HBc only" serological profile (HBsAg/anti-HBs negative). HBV DNA was detected in 12/113 (10.61%) "anti-HBc only" positive sera, representing 0.048% of all routinely tested samples. Due to extremely low viremia, HBV genome was successfully sequenced in only two sera where subgenotype D3 was confirmed. Mutational analyses of the S gene revealed multiple missense mutations. In addition to the M133I, Y134F, and G145R mutations, already associated with diagnostic escape, we also found nine novel OBI-related S-gene mutations - S136Y, F158L, K160N, E164G, S167L, A168V, L175S, S210I and F212C. CONCLUSIONS We detected multiple known and novel S gene mutations in 2/12 (16.6%) OBI cases, nevertheless, further studies are required to determine their role in the pathogenesis of OBI. Understanding the frequencies of clinically relevant HBV mutations may contribute to improvement of diagnostic protocols.
Collapse
Affiliation(s)
- Marina Bubonja-Šonje
- Department of Microbiology and Parasitology, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, Rijeka 51000, Croatia; Department of Clinical Microbiology, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka 51000, Croatia.
| | - Dolores Peruč
- Department of Microbiology and Parasitology, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, Rijeka 51000, Croatia; Department of Clinical Microbiology, Teaching Institute of Public Health of Primorsko-Goranska County, Krešimirova 52a, Rijeka, Croatia
| | - Maja Abram
- Department of Microbiology and Parasitology, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, Rijeka 51000, Croatia; Department of Clinical Microbiology, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka 51000, Croatia
| | - Bojana Mohar-Vitezić
- Department of Microbiology and Parasitology, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, Rijeka 51000, Croatia; Department of Clinical Microbiology, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka 51000, Croatia
| |
Collapse
|
2
|
Wang W, Lempp FA, Schlund F, Walter L, Decker CC, Zhang Z, Ni Y, Urban S. Assembly and infection efficacy of hepatitis B virus surface protein exchanges in 8 hepatitis D virus genotype isolates. J Hepatol 2021; 75:311-323. [PMID: 33845061 DOI: 10.1016/j.jhep.2021.03.025] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 03/04/2021] [Accepted: 03/24/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND & AIMS Chronic HDV infections cause the most severe form of viral hepatitis. HDV requires HBV envelope proteins for hepatocyte entry, particle assembly and release. Eight HDV and 8 HBV genotypes have been identified. However, there are limited data on the replication competence of different genotypes and the effect that different HBV envelopes have on virion assembly and infectivity. METHODS We subcloned complementary DNAs (cDNAs) of all HDV and HBV genotypes and systematically studied HDV replication, assembly and infectivity using northern blot, western blot, reverse-transcription quantitative PCR, and in-cell ELISA. RESULTS The 8 HDV cDNA clones initiated HDV replication with noticeable differences regarding replication efficacy. The 8 HBV-HBsAg-encoding constructs all supported secretion of subviral particles, however variations in envelope protein stoichiometry and secretion efficacy were observed. Co-transfection of all HDV/HBV combinations supported particle assembly, however, the respective pseudo-typed HDVs differed with respect to assembly kinetics. The most productive combinations did not correlate with the natural geographic distribution, arguing against an evolutionary adaptation of HDV ribonucleoprotein complexes to HBV envelopes. All HDVs elicited robust and comparable innate immune responses. HBV envelope-dependent differences in the activity of the EMA-approved entry inhibitor bulevirtide were observed, however efficient inhibition could be achieved at therapeutically applied doses. Lonafarnib also showed pan-genotypic activity. CONCLUSIONS HDVs from different genotypes replicate with variable efficacies. Variations in HDV genomes and HBV envelope proteins are both major determinants of HDV egress and entry efficacy, and consequently assembly inhibition by lonafarnib or entry inhibition by bulevirtide. These differences possibly influence HDV pathogenicity, immune responses and the efficacy of novel drug regimens. LAY SUMMARY HDV requires the envelope protein of HBV for assembly and to infect human cells. We investigated the ability of different HDV genotypes to infect cells and replicate. We also assessed the effect that envelope proteins from different HBV genotypes had on HDV infectivity and replication. Herein, we confirmed that genotypic differences in HDV and HBV envelope proteins are major determinants of HDV assembly, de novo cell entry and consequently the efficacy of novel antivirals.
Collapse
Affiliation(s)
- Wenshi Wang
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany.
| | - Florian A Lempp
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany; German Centre for Infection Research (DZIF), partner site Heidelberg, Heidelberg, Germany
| | - Franziska Schlund
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany
| | - Lisa Walter
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany
| | - Charlotte C Decker
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany
| | - Zhenfeng Zhang
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany
| | - Yi Ni
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany; German Centre for Infection Research (DZIF), partner site Heidelberg, Heidelberg, Germany
| | - Stephan Urban
- Department of Infectious Diseases, Molecular Virology, University Hospital Heidelberg, Heidelberg, Germany; German Centre for Infection Research (DZIF), partner site Heidelberg, Heidelberg, Germany.
| |
Collapse
|
3
|
Jiang X, Chang L, Yan Y, Wang L. Paradoxical HBsAg and anti-HBs coexistence among Chronic HBV Infections: Causes and Consequences. Int J Biol Sci 2021; 17:1125-1137. [PMID: 33867835 PMCID: PMC8040313 DOI: 10.7150/ijbs.55724] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 03/11/2021] [Indexed: 12/11/2022] Open
Abstract
Hepatitis B surface antigen (HBsAg) and Hepatitis B surface antibody (anti-HBs) were reported simultaneously among Hepatitis B virus (HBV) infections. HBsAg is a specific indicator of acute or chronic HBV infections, while anti-HBs is a protective antibody reflecting the recovery and immunity of hosts. HBsAg and anti-HBs coexist during seroconversion and then form immune complex, which is rare detected in clinical cases. However, with the promotion of vaccination and the application of various antiviral drugs, along with the rapid development of medical technology, the coexistence of HBsAg and anti-HBs has become more prevalent. Mutations in the viral genomes, immune status and genetic factors of hosts may contribute to the coexistence. Novel HBsAg assays, with higher sensitivity and ability to detect mutations or immune complexes, can also yield HBsAg/anti-HBs coexistence. The discovery of coexistence has shattered the idea of traditional serological patterns and raised questions about the effectiveness of vaccines. Worth noting is that HBsAg/anti-HBs double positivity is strongly associated with progressive liver diseases, especially hepatocellular carcinoma. In conclusion, viral mutations, host factors, and methodology impacts can all lead to the coexistence of HBsAg and anti-HBs. This coexistence is not an indicator of improvement, as an increased risk of adverse clinical outcomes still exists.
Collapse
Affiliation(s)
- Xinyi Jiang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, P.R. China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, P.R. China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, P.R. China
| | - Le Chang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, P.R. China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, P.R. China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, P.R. China
| | - Ying Yan
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, P.R. China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, P.R. China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, P.R. China
| | - Lunan Wang
- National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, P.R. China.,Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, P.R. China.,Graduate School, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, P.R. China
| |
Collapse
|
4
|
Jiang L, Li Y, Xu Z, Li X, Li Y, Liu Q, Wang P, Dong Y. Simultaneous electrochemical determination of two hepatitis B antigens using graphene-SnO 2 hybridized with sea urchin-like bimetallic nanoparticles. Mikrochim Acta 2021; 188:109. [PMID: 33660023 DOI: 10.1007/s00604-021-04763-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 02/16/2021] [Indexed: 10/22/2022]
Abstract
The hepatitis B virus (HBV) can cause chronic hepatitis and hepatocellular carcinoma. Hepatitis B surface antigen (HBs-Ag) and Hepatitis B e-antigen (HBe-Ag) are key markers for the diagnosis of HBV. In this study, electrodeposited gold was used as a sensing platform. Three-dimensional (3D) SnO2-loaded graphene sheets functionalized by Thionine (Thi) and ferrocene (Fc) and hybridized by sea urchin-like bimetallic nanoparticles (GS-SnO2-BMNPs) were used as redox probes for labeling antibodies to fabricate sandwich-type immunosensors for the simultaneous determination of HBs-Ag and HBe-Ag. The bimetallic nanoparticles, gold hybrid platinum nanoparticles (Au@Pt) and L-cysteine-connected gold-silver nanoparticles (Ag-cys-Au), have large electroactive surface areas. They were prepared by an efficient and economical method. Additionally, the sea urchin morphology accelerates spatial utilization, thus increasing the number of combination sites. Therefore, the immune probe can load a mass of signal source molecules (Thi and Fc). Furthermore, GS-SnO2-BMNPs (GS-SnO2-Au@Pt and GS-SnO2-Ag-cys-Au) with excellent electrical conductivity and bimetallic synergy can enhance the square wave voltammetry (SWV) signal. SWV was used to record the electrochemical signal by scanning the potential from - 0.6 to 0.6 V (vs. SCE). The signal peaks resulted from the reduction reaction of Thi and Fc, and two signal peaks were completely separate. The peak position and current intensity reflect the identity and level of the corresponding antigens. Therefore, the simultaneous detection of two viral biomarkers was achieved by the proposed immunosensor. The fabricated immunosensor showed a linear concentration range for HBs-Ag (0.01-100 ng·mL-1) and HBe-Ag (0.01-100 ng·mL-1), with detection limits for HBs-Ag and HBe-Ag of 4.67 pg·mL-1 and 4.68 pg·mL-1, respectively. The RSD of HBs-Ag ranged between 2.0 and 4.4%and the recovery was in the range 98.7 to 99.4%. For HBe-Ag the RSD was between 2.6 and 3.3% andrecoveries in the range 99.2 to 100.5% were obtained.
Collapse
Affiliation(s)
- Liping Jiang
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China.,College of Engineering, Yantai Nanshan University, Yantai, Shandong, 265700, People's Republic of China
| | - Yueyuan Li
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| | - Zhen Xu
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| | - Xinjin Li
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| | - Yueyun Li
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China.
| | - Qing Liu
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| | - Ping Wang
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| | - Yunhui Dong
- School of Chemical Engineering, Shandong University of Technology, Zibo, 255049, People's Republic of China
| |
Collapse
|
5
|
Effectiveness of PCR primers for the detection of occult hepatitis B virus infection in Mexican patients. PLoS One 2018; 13:e0205356. [PMID: 30304056 PMCID: PMC6179258 DOI: 10.1371/journal.pone.0205356] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 09/24/2018] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Occult hepatitis B infection (OBI) is defined as the presence of hepatitis B virus (HVB) DNA in the liver of HBsAg negative individuals with or without detectable viral DNA in serum. OBI is a diagnostic challenge as it is characterized by a very low viral load, intermittently detectable through time. Individuals with OBI can develop chronic hepatic disease, including liver cirrhosis and hepatocellular carcinoma. The aim of this work was to produce tools to improve OBI detection of the HVB genotypes prevalent in Mexico. METHODS We designed and tested primers to detect OBI in serum samples by nested and real-time PCR. Conserved sites in the viral genome were determined by alignment of the most frequent HBV genotypes in Mexico (H, G/H, F and D) and primers spanning the entire viral genome were designed for first round and nested PCR. Primers were tested in serum samples of 45 patients not co-infected with hepatitis C virus or with HIV, out of a group of 116 HBsAg (-)/anti-HBc (+) individuals. Primers were also tested in a control group with chronic HBV. Nested PCR products obtained from HBsAg (-)/anti-HBc (+) were sequenced and used to design primers for real-time PCR (SYBR Green). RESULTS The most effective primer pairs to detect HBV products by nested PCR targeted ORF regions: PreS2/P, S/P, X/PreC, and C; while by real-time PCR they targeted ORF regions PreS2/P, S/P, X, and C. Out of the 45 HBsAg (-)/anti-HBc (+) patients tested, the viral genome was detected in 28 (62.2%) and 34 (75.5%), with nPCR and real-time PCR respectively. CONCLUSION Primers designed for real-time PCR detected up to 75.5% of suspected OBI Mexican patients, with or without liver disease, which represents an improvement from previous PCR strategies.
Collapse
|
6
|
Lou S, Taylor R, Pearce S, Kuhns M, Leary T. An ultra-sensitive Abbott ARCHITECT ® assay for the detection of hepatitis B virus surface antigen (HBsAg). J Clin Virol 2018; 105:18-25. [PMID: 29843004 DOI: 10.1016/j.jcv.2018.05.009] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 05/14/2018] [Accepted: 05/20/2018] [Indexed: 12/18/2022]
Abstract
BACKGROUND Critical to the identification of HBV infection and the prevention of transfusion transmitted disease is the sensitive and accurate detection of Hepatitis B virus surface antigen (HBsAg). Improvements in HBsAg assay sensitivity approaching the performance of nucleic acid testing (NAT) are essential to further reduce the detection window for acute HBV infection in regions where NAT is not widely available. OBJECTIVES AND STUDY DESIGN An improved HBsAg assay on the fully-automated Abbott ARCHITECT® platform was developed to improve sensitivity, mutant and genotype detection. RESULTS The analytical sensitivity of the improved prototype assay is 5.2 mIU/ml, which is 3.86- to 14.54-fold more sensitive than comparator assays based on the WHO International Reference Standard. The enhanced sensitivity was also demonstrated with 27 HBV seroconversion panels, detecting more panel members (191 of 364) vs. the ARCHITECT® Qual I (144), Qual II (160) and PRISM® (148) HBsAg assays. Further, the assay detected 7 of 12 HBV DNA positive/HBsAg negative samples, and detected all evaluated mutants and genotypes with higher sensitivity than the comparator assays. The improvement in sensitivity did not diminish assay specificity, attaining 100% (95% CI, 99.97-100%) on 10,633 blood donors. CONCLUSIONS An Abbott ARCHITECT® HBsAg assay with clinical performance approaching that of mini-pool NAT (approximately 100 copies/ml was developed. The assay has superior HBsAg mutant and genotype detection and specificity, all of which are important for the diagnosis and management of HBV infection.
Collapse
Affiliation(s)
- Sheng Lou
- Diagnostics Research, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL,60064, USA.
| | - Russell Taylor
- Diagnostics Research, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL,60064, USA.
| | - Sandra Pearce
- Diagnostics Research, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL,60064, USA.
| | - Mary Kuhns
- Diagnostics Research, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL,60064, USA.
| | - Thomas Leary
- Diagnostics Research, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL,60064, USA.
| |
Collapse
|
7
|
Esposito A, Sabia C, Iannone C, Nicoletti GF, Sommese L, Napoli C. Occult Hepatitis Infection in Transfusion Medicine: Screening Policy and Assessment of Current Use of Anti-HBc Testing. Transfus Med Hemother 2017; 44:263-272. [PMID: 28924431 DOI: 10.1159/000460301] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 02/05/2017] [Indexed: 12/20/2022] Open
Abstract
HBV still represents a global risk factor in transfusion medicine. The residual risk of HBV is not limited to pre-seroconversion window period but it extends to donors with occult HBV infection (OBI) characterized by the presence of HBV DNA in liver and by the absence of the virus surface antigen. Each country developed an appropriate blood screening policy according to local HBV prevalence, yields of infectious units per different screening methods and cost-effectiveness. We underline the need of maintaining a high level of attention for OBI carrier identification in all blood banks worldwide where the screening procedures are generally based on a combination of both serological markers and nucleic acid amplification test. In this context, markers such as hepatitis B surface antibodies and hepatitis B core antibodies (anti-HBc) might be useful, although the use of this latter is highly debated and still controversial. Our aim is to give an overview on the relevant diagnostic approaches for the routine screening for HBV focusing on the feasibility of anti-HBc testing as precautionary measure in preventing OBI transmission worldwide. In our tailored algorithm, the loss of about 1% of 'anti-HBc only' donors, does not significantly affect the blood supply while improving recipient safety.
Collapse
Affiliation(s)
- Antonella Esposito
- Department of Internal and Specialty Medicine, U.O.C. Immunohematology, Transfusion Medicine and Transplant Immunology, Azienda Ospedaliera Universitaria, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy
| | - Chiara Sabia
- Department of Internal and Specialty Medicine, U.O.C. Immunohematology, Transfusion Medicine and Transplant Immunology, Azienda Ospedaliera Universitaria, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy
| | - Carmela Iannone
- Department of Internal and Specialty Medicine, U.O.C. Immunohematology, Transfusion Medicine and Transplant Immunology, Azienda Ospedaliera Universitaria, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy
| | - Giovanni F Nicoletti
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy
| | - Linda Sommese
- Department of Internal and Specialty Medicine, U.O.C. Immunohematology, Transfusion Medicine and Transplant Immunology, Azienda Ospedaliera Universitaria, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy
| | - Claudio Napoli
- Department of Internal and Specialty Medicine, U.O.C. Immunohematology, Transfusion Medicine and Transplant Immunology, Azienda Ospedaliera Universitaria, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy.,Department of Medical, Surgical, Neurological, Metabolic and Geriatric Sciences, Università degli Studi della Campania 'Luigi Vanvitelli', Naples, Italy.,Foundation SDN, Institute of Diagnostic and Nuclear Development, IRCCS, Naples, Italy
| |
Collapse
|
8
|
Comparative Efficacy, Safety and Immunogenicity of Hepavax-Gene TF and Engerix-B Recombinant Hepatitis B Vaccines in Neonates in China. Pediatr Infect Dis J 2017; 36:94-101. [PMID: 27753794 DOI: 10.1097/inf.0000000000001361] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND The aim of the study was to compare efficacy, immunogenicity and safety of Hepavax-Gene TF (thimerosal-free) vaccine with comparator in Chinese neonates. METHODS A double-blind, randomized, parallel-group, stratified study was conducted at multiple sites in China in healthy neonates, consisting of 3 doses of Hepavax-Gene TF or Engerix-B vaccines administered at birth, 1 and 6 months of age, with a 6-month follow-up after vaccination. On the basis of hepatitis B virus (HBV) infection status of mothers, infants were assigned to one of 2 study strata for mothers positive for HBV infection (stratum 1), with or without active replicating virus (substrata 1a, 1b), and for HBV negative mothers (stratum 2). RESULTS Mother-to-child HBV transmission was prevented in >95% of neonates immunized with Hepavax-Gene TF in stratum 1 at all timepoints and was noninferior to Engerix-B. Seroprotection rates (anti-HBs antibody ≥10 IU/L) at 1 and 6 months postvaccination for Hepavax-Gene TF were over 90% for all exposed neonates. Immunogenicity of Hepavax-Gene was noninferior to Engerix-B except for neonates in substratum 1a at 12 months. Geometric mean concentrations between vaccine groups were not significantly different for neonates at all timepoints except in substratum 1b at 7 months. Both vaccines were well tolerated and had similar local and systemic adverse event profiles. CONCLUSIONS Hepavax-Gene TF vaccine was equally effective and noninferior to Engerix-B in terms of prevention of mother-to-child HBV transmission in neonates born to mothers positive for hepatitis B surface antigen. Both vaccines elicited seroprotective levels in >90% of all exposed neonates at 12-month follow-up. Both vaccines were well tolerated with similar adverse event profiles.
Collapse
|
9
|
Tram DTN, Wang H, Sugiarto S, Li T, Ang WH, Lee C, Pastorin G. Advances in nanomaterials and their applications in point of care (POC) devices for the diagnosis of infectious diseases. Biotechnol Adv 2016; 34:1275-1288. [PMID: 27686397 PMCID: PMC7127209 DOI: 10.1016/j.biotechadv.2016.09.003] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 07/13/2016] [Accepted: 09/23/2016] [Indexed: 01/17/2023]
Abstract
Nanotechnology has gained much attention over the last decades, as it offers unique opportunities for the advancement of the next generation of sensing tools. Point-of-care (POC) devices for the selective detection of biomolecules using engineered nanoparticles have become a main research thrust in the diagnostic field. This review presents an overview on how the POC-associated nanotechnology, currently applied for the identification of nucleic acids, proteins and antibodies, might be further exploited for the detection of infectious pathogens: although still premature, future integrations of nanoparticles with biological markers that target specific microorganisms will enable timely therapeutic intervention against life-threatening infectious diseases.
Collapse
Affiliation(s)
- Dai Thien Nhan Tram
- Pharmacy Department National University of Singapore, Singapore 117543, Singapore.
| | - Hao Wang
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering, Drive 3, Singapore 117576, Singapore.
| | - Sigit Sugiarto
- Department of Chemistry, National University of Singapore, Singapore 117543, Singapore.
| | - Tao Li
- Department of Chemistry, National University of Singapore, Singapore 117543, Singapore.
| | - Wee Han Ang
- Department of Chemistry, National University of Singapore, Singapore 117543, Singapore.
| | - Chengkuo Lee
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering, Drive 3, Singapore 117576, Singapore.
| | - Giorgia Pastorin
- Pharmacy Department National University of Singapore, Singapore 117543, Singapore; NanoCore, Faculty of Engineering, National University of Singapore, Singapore 117576, Singapore; NUS Graduate School for Integrative Sciences and Engineering, Centre for Life Sciences (CeLS), Singapore 117456, Singapore.
| |
Collapse
|
10
|
YOUNG SHIHHAO, WEI TIENHSIN, LIN CHUNGCHI, CHU CHIJEN, LEE FAYAUH, YU MAYING, LU REIHWA, CHANG CHIAOYU, YANG PEILING, WANG MEIHUI, LIN HANCHIEH. Analysis of baseline hepatitis B virus DNA levels in chronic hepatitis B patients with non-hematological malignancies prior to the initiation of cancer chemotherapy. Mol Clin Oncol 2016; 5:165-170. [DOI: 10.3892/mco.2016.857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 04/01/2016] [Indexed: 11/05/2022] Open
|
11
|
Osiowy C, Kowalec K, Giles E. Discordant diagnostic results due to a hepatitis B virus T123A HBsAg mutant. Diagn Microbiol Infect Dis 2016; 85:328-333. [DOI: 10.1016/j.diagmicrobio.2016.04.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 04/04/2016] [Accepted: 04/06/2016] [Indexed: 12/20/2022]
|
12
|
Wang L, Chen W, Yu Y. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases. J Clin Lab Anal 2016; 31. [PMID: 27302692 DOI: 10.1002/jcla.22015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Accepted: 05/18/2016] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. METHODS Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. RESULTS For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. CONCLUSIONS The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method.
Collapse
Affiliation(s)
- Linchuan Wang
- Clinical Laboratory of the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, China
| | - Wei Chen
- Clinical Laboratory of the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, China
| | - Yan Yu
- Clinical Laboratory of Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi Province, China
| |
Collapse
|
13
|
Velay A, Jeulin H, Eschlimann M, Malvé B, Goehringer F, Bensenane M, Frippiat JP, Abraham P, Ismail AM, Murray JM, Combet C, Zoulim F, Bronowicki JP, Schvoerer E. Characterization of hepatitis B virus surface antigen variability and impact on HBs antigen clearance under nucleos(t)ide analogue therapy. J Viral Hepat 2016; 23:387-98. [PMID: 26742490 DOI: 10.1111/jvh.12498] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 11/01/2015] [Indexed: 12/15/2022]
Abstract
For hepatitis B virus (HBV)-related chronic infection under treatment by nucleos(t)ide analogues (NUCs), HBsAg clearance is the ultimate therapeutic goal but very infrequent. We investigated how HBV envelope protein variability could lead to differential HBsAg clearance on NUCs. For 12 HBV genotype D patients receiving NUCs, six resolvers (HBsAg clearance) were compared to six matched nonresolvers (HBsAg persistence). PreS/S amino acid (aa) sequences were analysed with bioinformatics to predict HBV envelope antigenicity and aa covariance. To enrich our analyses on very rare resolvers, these were compared with other HBV genotype D strains in three characterized clinical cohorts including common chronically infected patients. The sT125M+sP127T combination was observed in four nonresolvers of six, corroborated by aa covariance analysis, associated with a lower predicted antigenicity than sT125T+sP127P. Concordant features within this HBV key functional domain, at positions 125 and 127, were reported from two of the three comparative cohorts. In our hands, a lower ELISA reactivity of HBV-vaccinated mice sera was observed against the sT125M mutant. In the S gene, 56 aa changes in minor variants were detected in non-resolvers, mainly in the major hydrophilic region, vs 28 aa changes in resolvers. Molecular features in patients showing HBsAg persistence on NUCs argue in favour of a different aa pattern in the HBV S gene compared to those showing HBsAg clearance. In nonresolvers, a decrease in HBs 'a' determinant antigenicity and more frequent mutations in the S gene suggest a role for the HBV envelope characteristics in HBsAg persistence.
Collapse
Affiliation(s)
- A Velay
- EA 7300 'Stress, Immunité, Pathogènes', Université de Lorraine, Vandoeuvre-les-Nancy, France
| | - H Jeulin
- EA 7300 'Stress, Immunité, Pathogènes', Université de Lorraine, Vandoeuvre-les-Nancy, France.,Laboratoire de Virologie, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| | - M Eschlimann
- EA 7300 'Stress, Immunité, Pathogènes', Université de Lorraine, Vandoeuvre-les-Nancy, France
| | - B Malvé
- Laboratoire de Virologie, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| | - F Goehringer
- Service des Maladies Infectieuses et Tropicales, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| | - M Bensenane
- Service d'Hépato-gastroentérologie, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| | - J-P Frippiat
- EA 7300 'Stress, Immunité, Pathogènes', Université de Lorraine, Vandoeuvre-les-Nancy, France
| | - P Abraham
- Department of Clinical Virology, Christian Medical College, Vellore, Tamil Nadu, India
| | - A M Ismail
- Department of Clinical Virology, Christian Medical College, Vellore, Tamil Nadu, India
| | - J M Murray
- School of Mathematics and Statistics, UNSW Australia, Sydney, NSW, Australia
| | - C Combet
- Unité Inserm UI1052, Université de Lyon, Lyon, France
| | - F Zoulim
- Unité Inserm UI1052, Université de Lyon, Lyon, France
| | - J-P Bronowicki
- Service d'Hépato-gastroentérologie, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| | - E Schvoerer
- EA 7300 'Stress, Immunité, Pathogènes', Université de Lorraine, Vandoeuvre-les-Nancy, France.,Laboratoire de Virologie, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-les-Nancy, France
| |
Collapse
|
14
|
Ghosh M, Nandi S, Dutta S, Saha MK. Detection of hepatitis B virus infection: A systematic review. World J Hepatol 2015; 7:2482-2491. [PMID: 26483870 PMCID: PMC4606204 DOI: 10.4254/wjh.v7.i23.2482] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Revised: 08/18/2015] [Accepted: 09/30/2015] [Indexed: 02/06/2023] Open
Abstract
AIM: To review published methods for detection of hepatitis B virus (HBV) infection.
METHODS: A thorough search on Medline database was conducted to find original articles describing different methods or techniques of detection of HBV, which are published in English in last 10 years. Articles outlining methods of detection of mutants or drug resistance were excluded. Full texts and abstracts (if full text not available) were reviewed thoroughly. Manual search of references of retrieved articles were also done. We extracted data on different samples and techniques of detection of HBV, their sensitivity (Sn), specificity (Sp) and applicability.
RESULTS: A total of 72 studies were reviewed. HBV was detected from dried blood/plasma spots, hepatocytes, ovarian tissue, cerumen, saliva, parotid tissue, renal tissue, oocytes and embryos, cholangiocarcinoma tissue, etc. Sensitivity of dried blood spot for detecting HBV was > 90% in all the studies. In case of seronegative patients, HBV DNA or serological markers have been detected from hepatocytes or renal tissue in many instances. Enzyme linked immunosorbent assay and Chemiluminescent immunoassay (CLIA) are most commonly used serological tests for detection. CLIA systems are also used for quantitation. Molecular techniques are used qualitatively as well as for quantitative detection. Among the molecular techniques version 2.0 of the CobasAmpliprep/CobasTaqMan assay and Abbott’s real time polymerase chain reaction kit were found to be most sensitive with a lower detection limit of only 6.25 IU/mL and 1.48 IU/mL respectively.
CONCLUSION: Serological and molecular assays are predominant and reliable methods for HBV detection. Automated systems are highly sensitive and quantify HBV DNA and serological markers for monitoring.
Collapse
|
15
|
Boyd A, Maylin S, Moh R, Gabillard D, Menan H, Mahjoub N, Danel C, Anglaret X, Eholié SP, Girard PM, Zoulim F, Delaugerre C, Lacombe K. Identifying patients infected with hepatitis B virus in sub-Saharan Africa: potential for misclassification. Diagn Microbiol Infect Dis 2015; 83:248-51. [PMID: 26283522 DOI: 10.1016/j.diagmicrobio.2015.07.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Revised: 07/07/2015] [Accepted: 07/16/2015] [Indexed: 11/17/2022]
Abstract
Most research in sub-Saharan Africa establishes hepatitis B infection via one-time hepatitis B surface antigen (HBsAg) testing. Of 237 HIV-infected patients from two clinical trials testing HBsAg positive (MiniVidas®), 206 (86.9%) had validated serological tests using another assay (Architect). Discrepancies could be due to inactive infection, highlighting the importance of assessing hepatitis B virus infection phase.
Collapse
Affiliation(s)
- Anders Boyd
- INSERM, UMR_S1136, Institut Pierre Louis d'Epidémiologie et de Santé Publique, Paris, France.
| | - Sarah Maylin
- Laboratoire de Virologie, Hôpital Saint-Louis, AP-HP, Paris, France; Université Paris-Diderot, Paris, France
| | - Raoul Moh
- Programme PAC-CI, ANRS Research Site, Treichville University Hospital, Abidjan, Côte d'Ivoire
| | - Delphine Gabillard
- INSERM, U897, Epidémiologie-Biostatistique, Bordeaux, France; University of Bordeaux, ISPED, Bordeaux, France
| | - Hervé Menan
- Programme PAC-CI, ANRS Research Site, Treichville University Hospital, Abidjan, Côte d'Ivoire; Centre de Diagnostic et de Recherche sur le SIDA et les Maladies Opportunistes (CeDReS), Centre Hospitalier Universitaires (CHU) de Treichville, Abidjan, Côte d'Ivoire
| | - Nadia Mahjoub
- Laboratoire de Virologie, Hôpital Saint-Louis, AP-HP, Paris, France; Université Paris-Diderot, Paris, France
| | - Christine Danel
- Programme PAC-CI, ANRS Research Site, Treichville University Hospital, Abidjan, Côte d'Ivoire; INSERM, U897, Epidémiologie-Biostatistique, Bordeaux, France; University of Bordeaux, ISPED, Bordeaux, France
| | - Xavier Anglaret
- Programme PAC-CI, ANRS Research Site, Treichville University Hospital, Abidjan, Côte d'Ivoire; INSERM, U897, Epidémiologie-Biostatistique, Bordeaux, France; University of Bordeaux, ISPED, Bordeaux, France
| | - Serge Paul Eholié
- Programme PAC-CI, ANRS Research Site, Treichville University Hospital, Abidjan, Côte d'Ivoire; Department of Infectious and Tropical Diseases, Treichville University Teaching Hospital, Abidjan, Côte d'Ivoire; Medical School, University Felix Houphouet Boigny, Abidjan, Côte d'Ivoire
| | - Pierre-Marie Girard
- Department of Infectious and Tropical Diseases, Saint-Antoine Hospital, AP-HP, Paris, France; Sorbonne Universités, UPMC Univ Paris 06, UMR_S 1136, Institut Pierre Louis d'Epidémiologie et de Santé Publique, Paris, France
| | - Fabien Zoulim
- Centre de Recherche sur le Cancer de Lyon, Equipes 15 et 16, INSERM, Unité 1052, CNRS, UMR 5286, Lyon, France
| | - Constance Delaugerre
- Laboratoire de Virologie, Hôpital Saint-Louis, AP-HP, Paris, France; INSERM U941, Paris, France; Université Paris-Diderot, Paris, France
| | - Karine Lacombe
- Department of Infectious and Tropical Diseases, Saint-Antoine Hospital, AP-HP, Paris, France; Sorbonne Universités, UPMC Univ Paris 06, UMR_S 1136, Institut Pierre Louis d'Epidémiologie et de Santé Publique, Paris, France
| | | |
Collapse
|
16
|
Hirzel C, Pfister S, Gorgievski-Hrisoho M, Wandeler G, Zuercher S. Performance of HBsAg point-of-care tests for detection of diagnostic escape-variants in clinical samples. J Clin Virol 2015. [PMID: 26209374 DOI: 10.1016/j.jcv.2015.05.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND Hepatitis B viruses (HBV) harboring mutations in the a-determinant of the Hepatitis B surface antigen (HBsAg) are associated with reduced reactivity of HBsAg assays. OBJECTIVES To evaluate the sensitivity and specificity of three HBsAg point-of-care tests for the detection of HBsAg of viruses harboring HBsAg mutations. STUDY DESIGN A selection of 50 clinical plasma samples containing HBV with HBsAg mutations was used to evaluate the performance of three HBsAg point-of-care tests (Vikia(®), bioMérieux, Marcy-L'Étoile, France. Alere Determine HBsAg™, Iverness Biomedical Innovations, Köln, Germany. Quick Profile™, LumiQuick Diagnostics, California, USA) and compared to the ARCHITECT HBsAg Qualitative(®) assay (Abbott Laboratories, Sligo, Ireland). RESULTS The sensitivity of the point-of-care tests ranged from 98% to 100%. The only false-negative result occurred using the Quick Profile™ assay with a virus harboring a D144A mutation. CONCLUSIONS The evaluated point-of-care tests revealed an excellent sensitivity in detecting HBV samples harboring HBsAg mutations.
Collapse
Affiliation(s)
- Cédric Hirzel
- Department of Infectious Diseases, Bern University Hospital and University of Bern, Switzerland.
| | - Stefan Pfister
- Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | | | - Gilles Wandeler
- Department of Infectious Diseases, Bern University Hospital and University of Bern, Switzerland; Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland
| | - Samuel Zuercher
- Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
17
|
Yildiz UH, Inci F, Wang S, Toy M, Tekin HC, Javaid A, Lau DTY, Demirci U. Recent advances in micro/nanotechnologies for global control of hepatitis B infection. Biotechnol Adv 2015; 33:178-190. [PMID: 25450190 PMCID: PMC4433022 DOI: 10.1016/j.biotechadv.2014.11.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Revised: 11/03/2014] [Accepted: 11/04/2014] [Indexed: 12/18/2022]
Abstract
The control of hepatitis B virus (HBV) infection is a challenging task, specifically in developing countries there is limited access to diagnostics and antiviral treatment mainly due to high costs and insufficient healthcare infrastructure. Although the current diagnostic technologies can reliably detect HBV, they are relatively laborious, impractical and require expensive resources that are not suitable for resource-limited settings. Advances in micro/nanotechnology are pioneering the development of new generation methodologies in diagnosis and screening of HBV. Owing to combination of nanomaterials (metal/inorganic nanoparticles, carbon nanotubes, etc.) with microfabrication technologies, utilization of miniaturized sensors detecting HBV and other viruses from ultra-low volume of blood, serum and plasma is realized. The state-of-the-art microfluidic devices with integrated nanotechnologies potentially allow for inexpensive HBV screening at low cost. This review aims to highlight recent advances in nanotechnology and microfabrication processes that are employed for developing point-of-care (POC) HBV assays.
Collapse
Affiliation(s)
- U Hakan Yildiz
- Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford for Cancer Early Detection, Palo Alto, CA 94304, United States
| | - Fatih Inci
- Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford for Cancer Early Detection, Palo Alto, CA 94304, United States
| | - ShuQi Wang
- Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford for Cancer Early Detection, Palo Alto, CA 94304, United States
| | - Mehlika Toy
- Department of Surgery, Stanford School of Medicine, Palo Alto, CA, United States
| | - H Cumhur Tekin
- Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford for Cancer Early Detection, Palo Alto, CA 94304, United States
| | - Asad Javaid
- Department of Medicine, Beth Israel Deaconnes Medical Center, Harvard Medical School, Boston, MA, United States
| | - Daryl T-Y Lau
- Department of Medicine, Beth Israel Deaconnes Medical Center, Harvard Medical School, Boston, MA, United States
| | - Utkan Demirci
- Demirci Bio-Acoustic-MEMS in Medicine (BAMM) Laboratory, Stanford University School of Medicine, Canary Center at Stanford for Cancer Early Detection, Palo Alto, CA 94304, United States.
| |
Collapse
|
18
|
Liu TW, Yeh ML, Huang CF, Lin IL, Huang JF, Dai CY, Chen YL, Chuang WL, Yu ML. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution. Kaohsiung J Med Sci 2014; 31:26-33. [PMID: 25600917 DOI: 10.1016/j.kjms.2014.10.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Revised: 07/13/2014] [Accepted: 08/16/2014] [Indexed: 12/22/2022] Open
Abstract
Hepatitis B virus surface antigen (HBsAg) levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay), compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay) and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys). A total of 130 sera samples obtained from 87 hepatitis B virus (HBV)-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44-9.53%) and R(2) = 0.996-1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p < 0.01). With regard to subgroups, correlations between the two Architect assays were better in the hepatitis B e antigen (HBeAg)-negative group (HBeAg-negative group vs. HBeAg-positive group: R = 0.885 vs. R = 0.865, both p < 0.01) and low HBV DNA group (low DNA group vs. high DNA group: R = 0.886 vs. R = 0.844, both p < 0.01). Significant correlations were also found between the results of the Elecsys and Architect assays (R > 0.93 in all cases). In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.
Collapse
Affiliation(s)
- Ta-Wei Liu
- Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Ming-Lun Yeh
- Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan; College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Hepatitis Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chung-Feng Huang
- College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Occupational Medicine, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - I-Ling Lin
- Department of Medical Laboratory Science and Biotechnology, College of Health Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Jee-Fu Huang
- College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Internal Medicine, Kaohsiung Municipal Hsiao-Kang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chia-Yen Dai
- Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan; College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Hepatitis Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yao-Li Chen
- College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Division of General Surgery, Department of Surgery, Changhua Christian Hospital, Changhua, Taiwan.
| | - Wan-Long Chuang
- Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan; College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan; Hepatitis Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Ming-Lung Yu
- Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan; College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
19
|
Ren ZQ, Liu TC, Hou JY, Chen MJ, Chen ZH, Lin GF, Wu YS. A rapid and sensitive method based on magnetic beads for the detection of hepatitis B virus surface antigen in human serum. LUMINESCENCE 2013; 29:591-7. [PMID: 24136927 DOI: 10.1002/bio.2587] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 06/17/2013] [Accepted: 08/15/2013] [Indexed: 12/17/2022]
Abstract
Current clinically assays, such as enzyme-linked immunosorbent assay and chemiluminescence immunoassay, for hepatitis B surface antigen (HBsAg) are inferior in terms of either sensitivity and accuracy or rapid and high-throughput analysis. A novel assay based on magnetic beads and time-resolved fluoroimmunoassay was developed for the quantitative determination of HBsAg in human serum. HBsAg was captured using two types of anti-HBsAg monoclonal antibodies (B028, S015) immobilized on to magnetic beads and detected using europium-labeled anti-HBsAg polyclonal detection antibody. Finally, the assay yielded a high sensitivity (0.02 IU/mL) and a wide dynamic range (0.02-700 IU/mL) for HBsAg when performed under optimal conditions. Satisfactory accuracy, recovery and specificity were also demonstrated. The intra- and interassay coefficients of variation were 4.7-8.7% and 3.8-7.5%, respectively. The performance of this assay was further assessed against a well-established commercial chemiluminescence immunoassay kit with 399 clinical serum samples. It was revealed that the test results for the two methods were in good correlation (Y = 1.182X - 0.017, R = 0.989). In the current study, we demonstrated that this novel time-resolved fluoroimmunoassay could be used: as a highly sensitive, automated and high-throughput immunoassay for the diagnosis of acute or chronic hepatitis B virus infection; for the screening of blood or organ donors; and for the surveillance of persons at risk of acquiring or transmitting hepatitis B virus.
Collapse
Affiliation(s)
- Zhi-Qi Ren
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|
20
|
Hepatitis B virus infection among first-time blood donors in Italy: prevalence and correlates between serological patterns and occult infection. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2013; 11:281-8. [PMID: 23399361 DOI: 10.2450/2012.0160-12] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 07/16/2012] [Accepted: 10/11/2012] [Indexed: 12/16/2022]
Abstract
BACKGROUND A prospective, 1-year study was performed among Italian first-time, volunteer blood donors, who account for 12% of all donations, in order to assess the frequency and serological patterns of hepatitis B virus infection and the presence of occult infection. MATERIALS AND METHODS Consecutive donors (n=31,190) from 21 blood transfusion centres, from age classes not subjected to universal HBV vaccination, were tested for HBsAg and anti-HBc by commercial immunoassays. Other HBV serological markers were searched for and qualitative and quantitative assessments of HBV-DNA were made in HBsAg and/or anti-HBc-positive individuals. RESULTS Of the 31,190 donors studied, 100 (0.32%) were positive for both HBsAg and anti-HBc, 2 for HBsAg (0.01%) alone, and 2,593 (8.3%) for anti-HBc. Of these last, 86.7% were also positive for anti-HBs (with or without anti-HBe), 2.9% were positive for anti-HBe without anti-HBs and 10.4% had no other HBV markers (anti-HBc alone). A general north-south increasing gradient of HBV prevalence was observed. Circulating HBV-DNA was found in 96.8% of HBsAg-positive subjects as compared to 0.55% (12/2,186) of anti-HBc-positive/HBsAg-negative subjects, with higher frequencies among anti-HBs-negative than among anti-HBs-positive ones (1.68% vs. 0.37%; p <0.01) and among the 57 cases positive for both anti-HBc and anti-HBe (7%). HBV-DNA levels were significantly higher in HBsAg-positive subjects than in HBsAg-negative ones (median: 456 IU/mL vs. 38 IU/mL). CONCLUSIONS The prevalence of HBV infection among Italian first-time blood donors is much lower than in the past. The presence of occult infections in this group was confirmed (frequency: 1 in 2,599), supporting the hypothesis of long-term persistence of HBV infection after clearance of HBsAg. HBsAg and nucleic acid amplification testing for blood screening and vaccination against HBV are crucial in order to further reduce the risk of transfusion-transmitted HBV towards zero.
Collapse
|
21
|
Dai J, Chen EQ, Bai L, Gong DY, Zhou QL, Cheng X, Huang FJ, Tang H. Biological characteristics of the rtA181T/sW172* mutant strain of Hepatitis B virus in animal model. Virol J 2012; 9:280. [PMID: 23171829 PMCID: PMC3515399 DOI: 10.1186/1743-422x-9-280] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 10/16/2012] [Indexed: 02/07/2023] Open
Abstract
Background The effects of Hepatitis B virus (HBV) rtA181T/sW172* mutation on viral replication and pathogenicity was concerned recently. This study aimed to investigate the biological characteristics of rtA181T/sW172* mutant strain of HBV in animal model. Methods The rtA181T/sW172* mutant plasmid was constructed using the pHBV4.1 (wild type HBV) as a template. The wild and mutant HBV replication mouse models were established utilizing a hydrodynamic technique. The titers of hepatitis B surface antigen (HBsAg), hepatitis B e antigen, and HBV DNA in serum, and the levels of HBsAg, hepatitis B core antigen(HBcAg), HBV DNA replication intermediates (HBV DNA RI) and HBV RNA in liver were measured after 1, 3, 5, 7, 10, 12 and 15 days of plasmid injection. Results In wild-type HBV replication mouse model, serum HBsAg was high on day 1, 3, and 5, but became lower since day 7; while in mutant HBV mouse model, serum HBsAg was always at very low level. In liver tissues, HBV DNA RI of wild type HBV was detected on day 1 after transfection. The level subsequently peaked on day 3, gradually declined after day 5, and was almost undetectable on day 10. However, the HBV DNA RI levels of the mutant strain were always higher and lasted longer until day 15. Consistently, the expression levels of HBsAg and HBcAg in liver of the mutant group were significantly increased. Conclusions In the case of the HBV rtA181T/sW172* mutation, the secretion of serum HBsAg was impaired, whereas HBV DNA replication and HBsAg/HBcAg expression were increased in liver. These results suggest that the mutation can impair HBsAg secretion, and may cause the accumulation of viral core particles in liver.
Collapse
Affiliation(s)
- Jie Dai
- Center of Infectious Diseases, West China Hospital, Sichuan University, Chengdu, 610041, China
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Alavian SM, Carman WF, Jazayeri SM. HBsAg variants: diagnostic-escape and diagnostic dilemma. J Clin Virol 2012; 57:201-8. [PMID: 22789139 DOI: 10.1016/j.jcv.2012.04.027] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2011] [Revised: 01/23/2012] [Accepted: 04/18/2012] [Indexed: 12/11/2022]
Abstract
A wide variety of commercial assays is available for the detection of hepatitis B surface antigen (HBsAg). Clearly, the sensitivity of an assay to detect a variant is dependent on the anti-HBs usage. Thus, it is not surprising that there are examples of variants that cannot be detected by all assays. Data from Europe, Asia and Africa about HBsAg variants which are not recognized by either monoclonal or polyclonal antibodies specific for wild-type group 'a' determinant, but positive by DNA polymerase chain reaction (PCR) in chronic patients and from vaccinated children are increasing. This would impose a challenge for public health issues of hepatitis B virus. In this review we tried to summarize the discrepancies between results of HBsAg assays and to explain some rationales for these inconsistencies.
Collapse
Affiliation(s)
- Seyed Moayed Alavian
- Baqiyatallah University of Medical Sciences, Baqiyatallah Research Centre for Gastroenterology and Liver Disease, Tehran, Iran
| | | | | |
Collapse
|
23
|
Servant-Delmas A, Mercier-Darty M, Ly TD, Wind F, Alloui C, Sureau C, Laperche S. Variable capacity of 13 hepatitis B virus surface antigen assays for the detection of HBsAg mutants in blood samples. J Clin Virol 2012; 53:338-45. [DOI: 10.1016/j.jcv.2012.01.003] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2012] [Accepted: 01/05/2012] [Indexed: 12/11/2022]
|
24
|
Amino acid substitutions at positions 122 and 145 of hepatitis B virus surface antigen (HBsAg) determine the antigenicity and immunogenicity of HBsAg and influence in vivo HBsAg clearance. J Virol 2012; 86:4658-69. [PMID: 22301154 DOI: 10.1128/jvi.06353-11] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
A variety of amino acid substitutions, such as K122I and G145R, have been identified around or within the a determinant of hepatitis B surface antigen (HBsAg), impair HBsAg secretion and antibody binding, and may be responsible for immune escape in patients. In this study, we examined how different substitutions at amino acid positions 122 and 145 of HBsAg influence HBsAg expression, secretion, and recognition by anti-HBs antibodies. The results showed that the hydrophobicity, the presence of the phenyl group, and the charges in the side chain of the amino acid residues at position 145 reduced HBsAg secretion and impaired reactivity with anti-HBs antibodies. Only the substitution K122I at position 122 affected HBsAg secretion and recognition by anti-HBs antibodies. Genetic immunization in mice demonstrated that the priming of anti-HBs antibody response was strongly impaired by the substitutions K122I, G145R, and others, like G145I, G145W, and G145E. Mice preimmunized with wild-type HBsAg (wtHBsAg) or variant HBsAg (vtHBsAg) were challenged by hydrodynamic injection (HI) with a replication-competent hepatitis B virus (HBV) clone. HBsAg persisted in peripheral blood for at least 3 days after HI in mice preimmunized with vtHBsAg but was undetectable in mice preimmunized with wtHBsAg, indicating that vtHBsAgs fail to induce proper immune responses for efficient HBsAg clearance. In conclusion, the biochemical properties of amino acid residues at positions 122 and 145 of HBsAg have a major effect on antigenicity and immunogenicity. In addition, the presence of proper anti-HBs antibodies is indispensable for the neutralization and clearance of HBsAg during HBV infection.
Collapse
|
25
|
Svicher V, Cento V, Bernassola M, Neumann-Fraune M, Hemert FV, Chen M, Salpini R, Liu C, Longo R, Visca M, Romano S, Micheli V, Bertoli A, Gori C, Ceccherini-Silberstein F, Sarrecchia C, Andreoni M, Angelico M, Ursitti A, Spanò A, Zhang JM, Verheyen J, Cappiello G, Perno CF. Novel HBsAg markers tightly correlate with occult HBV infection and strongly affect HBsAg detection. Antiviral Res 2012; 93:86-93. [DOI: 10.1016/j.antiviral.2011.10.022] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2011] [Revised: 10/26/2011] [Accepted: 10/30/2011] [Indexed: 02/06/2023]
|