Effect of Interpenetrating Polymer Network (IPN) Thermoplastic Resin on Flexural Strength of Fibre-Reinforced Composite and the Penetration of Bonding Resin into Semi-IPN FRC Post. Polymers (Basel) 2021; 13:polym13183200. [PMID: 34578101 PMCID: PMC8468106 DOI: 10.3390/polym13183200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 09/16/2021] [Accepted: 09/18/2021] [Indexed: 11/17/2022] Open
Abstract
The purpose of this study was to evaluate the effects of interpenetrating polymer network (IPN) thermoplastic resin on the flexural strength of fibre-reinforced composite (FRC) with different IPN polymer compositions. The penetration of bonding resin into semi-IPN FRC posts was also evaluated. The IPN thermoplastic resin used was UDMA-MMA monomer with either PMMA (0.5%, 2%, 5%) or PMMA-copolymer (0.5%, 2%). A no added IPN polymer resin was also made. Mixed resin was impregnated to S- and E-glass fibre rovings. These resins and resin impregnated fibres were used for flexural strength (FS) test. To evaluate the penetration of bonding resin into semi-IPN post, SEM observation was done with various impregnation time and polymerization mehods (hand-light- and oven-cure). The result of FS was recorded from 111.7 MPa (no-IPN polymer/no-fibre-reinforcement) to 543.0 MPa (5% PMMA/S-glass FRC). ANOVA showed that there were significant differences between fibre-reinforcement and no-fibre-reinforcement (p < 0.01) both in S- and E-glass fibre groups, and between 0.5% PMMA and 5% PMMA in the S-glass FRC group. SEM micrographs showed that the penetration layers of bonding resin into hand-light cured semi-IPN posts were different according to impregnation time. Fibre reinforcement is effective to improve flexural strength. The depth of penetration layer of bonding resin into semi-IPN matrix resin was improved when a hand-light cure was used.
Collapse
|
2
|
Study on Manufacturing Technology of Ag-8.5Au-3.5Pd Fine Alloy Wire. MICROMACHINES 2021; 12:mi12080938. [PMID: 34442560 PMCID: PMC8399038 DOI: 10.3390/mi12080938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/04/2021] [Accepted: 08/05/2021] [Indexed: 11/16/2022]
Abstract
The performance of Ag-8.5Au-3.5Pd alloy wire after cold deformation and annealing were analyzed by SEM (scanning electron microscope), strength tester and resistivity tester. The processing process and performance change characteristics of Ag-8.5Au-3.5Pd alloy wire were studied. The results show that alloy wire grains gradually form a fibrous structure along with the increase in deformation. The strength of the wire increases with the increase in deformation rate, but the increase trend becomes flat once the deformation rate is higher than 92.78%; the resistivity of Ag-8.5Au-3.5Pd alloy wire decreases with the increase in annealing temperature, reaching minimum (2.395 × 10−8 Ω·m) when the annealing temperature is 500 °C; the strength of Ag-8.5Au-3.5Pd alloy wire decreases with the increase in annealing temperature. When the annealing temperature is 500 °C, the strength and elongation of the φ0.2070 mm Ag-8.5Au-3.5Pd alloy wire are 287 MPa and 25.7%, respectively; the fracture force and elongation of φ0.020 mm Ag-8.5Au-3.5Pd alloy wire are 0.0876 N and 14.8%, respectively. When the annealing temperature is 550 °C, the metal grains begin to grow and the mechanical performance decrease; the φ0.020 mm Ag-8.5Au-3.5Pd alloy wire have good surface quality when the tension range is 2.5–3.0 g.
Collapse
|
3
|
Lu Y, Zhao C, Ren L, Guo S, Gan Y, Yang C, Wu S, Lin J, Huang T, Yang K, Lin J. Preliminary assessment of metal-porcelain bonding strength of CoCrW alloy after 3wt.% Cu addition. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 63:37-45. [PMID: 27040193 DOI: 10.1016/j.msec.2016.02.057] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2015] [Revised: 01/21/2016] [Accepted: 02/19/2016] [Indexed: 11/16/2022]
Abstract
In this work, a novel Cu-bearing CoCrW alloy fabricated by selective laser melting for dental application has been studied. For its successful application, the bonding strength of metal-porcelain is essential to be systematically investigated. Therefore, the aim of this study was to evaluate the metal-porcelain bonding strength of CoCrWCu alloy by three-point bending test, meanwhile the Ni-free CoCrW alloy was used as control. The oxygen content was investigated by an elemental analyzer; X-ray photoelectron spectroscopy (XPS) was used to analyze the surface chemical composition of CoCrW based alloy after preoxidation treatment; the fracture mode was investigated by X-ray energy spectrum analysis (EDS) and scanning electron microscope (SEM). Result from the oxygen content analysis showed that the content of oxygen dramatically increased after the Cu addition. And the XPS suggested that Co-oxidation, Cr2O3, CrO2, WO3, Cu2O and CuO existed on the preoxidated surface of the CoCrWCu alloy; the three-point bending test showed that the bonding strength of the CoCrWCu alloy was 43.32 MPa, which was lower than that of the CoCrW group of 47.65 MPa. However, the average metal-porcelain bonding strength is significantly higher than the minimum value in the ISO 9693 standard. Results from the SEM images and EDS indicated that the fracture mode of CoCrWCu-porcelain was mixed between cohesive and adhesive. Based on the results obtained in this study, it can be indicated that the Cu-bearing CoCrW alloy fabricated by the selective laser melting is a promising candidate for use in dental application.
Collapse
Affiliation(s)
- Yanjin Lu
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Chaoqian Zhao
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Ling Ren
- Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang, China
| | - Sai Guo
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Yiliang Gan
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Chunguang Yang
- Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang, China
| | - Songquan Wu
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Junjie Lin
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Tingting Huang
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China
| | - Ke Yang
- Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang, China.
| | - Jinxin Lin
- Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou, China.
| |
Collapse
|
4
|
Kajima Y, Takaichi A, Yasue T, Doi H, Takahashi H, Hanawa T, Wakabayashi N. Evaluation of the shear bond strength of dental porcelain and the low magnetic susceptibility Zr-14Nb alloy. J Mech Behav Biomed Mater 2015; 53:131-141. [PMID: 26318573 DOI: 10.1016/j.jmbbm.2015.08.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 08/01/2015] [Accepted: 08/04/2015] [Indexed: 11/16/2022]
Abstract
The aim of this study was to investigate the bond strength of dental porcelain and the preheated Zr-14Nb alloy, and compare this strength with that of titanium. White oxide layers, which were predominantly composed of monoclinic zirconia, were formed on the preheated sample groups, and exhibited a greater roughness than the control samples. At the metal-ceramic interface, a greater Nb diffusion range was observed than in the control samples. The bond strengths of the samples subjected to 20min preheating treatment were the lowest (33.6 ± 3.2 MPa), which may be ascribed to the formation of a brittle thick oxide layer under excessive heat treatment. The samples subjected to this heat treatment for 5 min exhibited the highest mean bond strength (43.7 ± 5.9 MPa), which was significantly higher than that of titanium (35.3 ± 3.5 MPa). Thus, the Zr-14Nb alloy is a promising candidate for fixed dental prosthesis, as long as the appropriate treatment conditions are adopted.
Collapse
Affiliation(s)
- Yuka Kajima
- Removable Partial Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Atsushi Takaichi
- Removable Partial Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan.
| | - Tohru Yasue
- Fixed Prosthetic Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Hisashi Doi
- Metallic Biomaterials, Biomedical Materials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
| | - Hidekazu Takahashi
- Oral Biomaterials Engineering, Course of Oral Health Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Takao Hanawa
- Metallic Biomaterials, Biomedical Materials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
| | - Noriyuki Wakabayashi
- Removable Partial Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| |
Collapse
|
5
|
Effect of heating palladium-silver alloys on ceramic bond strength. J Prosthet Dent 2015. [PMID: 26213266 DOI: 10.1016/j.prosdent.2015.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM The effects of different heat treatments on the internal oxidation and metal-ceramic bond in Pd-Ag alloys with different trace elements require further documentation. PURPOSE The purpose of this in vitro study was to determine whether heat treatment affects the metal-ceramic bond strength of 2 Pd-Ag alloys containing different trace elements. MATERIAL AND METHODS Thirteen cast specimens (25×3×0.5 mm) from each of 2 Pd-Ag alloy groups (W-1 and Argelite 61+3) were allocated to heat treatments before porcelain application: heating under reduced atmospheric pressure of 0.0014 MPa and 0.0026 MPa and heating under normal atmospheric pressure. Bond strengths were evaluated using a 3-point bending test according to ISO9693. Results were analyzed using 2-way ANOVA and Tukey HSD test (α=.05). Visual observation was used to determine the failure types of the fractured specimens. Scanning electron microscopy and energy dispersive spectroscopy were used to study morphologies, elemental compositions, and distributions in the specimens. RESULTS The W-1 group had a mean bond strength significantly higher than that of Argelite 61+3 (P<.001). Heating under reduced atmospheric pressures of 0.0014 MPa and 0.0026 MPa resulted in similar bond strengths (P=.331), and both pressures had significantly higher bond strengths than that of heating under normal atmospheric pressure (P=.002, P<.001). Heating under different air pressures resulted in Pd-Ag alloys that contained either Sn or In and Ga, with various degrees of internal oxidation and different quantities of metallic nodules. CONCLUSIONS Heating under reduced atmospheric pressure effectively improved the bond strength of the ceramic-to-Pd-Ag alloys.
Collapse
|
6
|
Li J, Ye X, Li B, Liao J, Zhuang P, Ye J. Effect of oxidation heat treatment on the bond strength between a ceramic and cast and milled cobalt-chromium alloys. Eur J Oral Sci 2015; 123:297-304. [PMID: 26104804 DOI: 10.1111/eos.12199] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/27/2015] [Indexed: 11/28/2022]
Abstract
There is a dearth of dental scientific literature on the effect of different oxidation heat treatments (OHTs) (as surface pretreatments) on the bonding performance of cast and milled cobalt-chromium (CoCr) alloys. The objective of this study was to evaluate the effect of different OHTs on the bond strength between a ceramic and cast and milled CoCr alloys. Cobalt-chromium metallic specimens were prepared using either a cast or a milled method. Specimens were subjected to four different OHT methods: without OHT; OHT under normal atmospheric pressure; OHT under vacuum; and OHT under vacuum followed by sandblasting. The metal-ceramic bond strength was evaluated using a three-point bending test according to ISO9693. Scanning electron microscopy and energy-dispersive spectroscopy were used to study the specimens' microstructure and elemental composition. The bond strength was not affected by the CoCr manufacturing method. Oxidation heat treatment performed under normal atmospheric pressure resulted in the highest bond strength. The concentration of oxygen on the alloy surfaces varied with the different pretreatment methods in the following order: OHT under normal atmospheric pressure > OHT under vacuum > without OHT ≈ OHT under vacuum followed by sandblasting.
Collapse
Affiliation(s)
- Jieyin Li
- Department of Prosthodontics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Stomatology, Jieyang People's Hospital, Jieyang, China
| | - Xiuhua Ye
- Department of Prosthodontics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Bohua Li
- Department of Stomatology, Henan Provincial People's Hospital, Zhengzhou, China
| | - Juankun Liao
- Department of Prosthodontics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Peilin Zhuang
- Department of Prosthodontics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Jiantao Ye
- Department of Prosthodontics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
7
|
Hong JT, Shin SY. A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy. J Adv Prosthodont 2014; 6:372-8. [PMID: 25352959 PMCID: PMC4211053 DOI: 10.4047/jap.2014.6.5.372] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Revised: 05/15/2014] [Accepted: 05/20/2014] [Indexed: 11/26/2022] Open
Abstract
PURPOSE The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (α=.05). RESULTS The 3-point bending test showed the strongest (40.42 ± 5.72 MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy (37.71 ± 2.46 MPa), precious metal alloy containing 83% of gold (35.89 ± 1.93 MPa), and precious metal alloy containing 32% of gold (34.59 ± 2.63 MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).
Collapse
Affiliation(s)
- Jun-Tae Hong
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Soo-Yeon Shin
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|