1
|
Mangano FG, Yang KR, Lerner H, Porrà T, Khachatryan LG, Gordienko ID, Admakin O. 3D-printed short-span hybrid composite implant-supported restorations fabricated through tilting stereolithography: A retrospective clinical study on 85 patients with 1 year of follow-up. J Dent 2024; 147:105095. [PMID: 38788917 DOI: 10.1016/j.jdent.2024.105095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/12/2024] [Accepted: 05/21/2024] [Indexed: 05/26/2024] Open
Abstract
PURPOSE To report the clinical results obtained with fixed short-span (single crowns [SCs] and fixed partial prostheses [FPPs]) implant-supported hybrid composite restorations fabricated through tilting stereolithography (TSLA). METHODS This retrospective clinical study included 85 patients who had been restored with 95 fixed short-span implant-supported hybrid composite (Irix Max®, DWS Systems) restorations (70 SCs and 25 FPPs up to three units) fabricated with TSLA. The full-digital model-free workflow was based on intraoral implant scanning, computer-assisted design (CAD) and 3D printing using TSLA (Dfab®, DWS Systems). The primary outcomes were the marginal adaptation, the quality of the occlusal and interproximal contact points, and the chromatic integration of the restorations, assessed independently by two experienced operators (a prosthodontist and a periodontist). A score from 1 to 5 (with 5 as the highest value, 4 for satisfactory quality, 3 for acceptable quality, and 2 and 1 as the lowest values, expressing unsatisfactory quality) was assigned by each operator to each restoration at delivery. The secondary outcomes were the survival and success of the restorations at the 1-year follow-up. The restoration was defined as successful in the absence of any complications throughout the follow-up period. A statistical analysis was conducted. RESULTS For the quality of the marginal closure and occlusal and interproximal contact points, the 3D-printed hybrid composite restorations scored highly; the aesthetic integration was satisfactory. One year after placement, all restorations survived, with a low incidence (4.2 % overall, 5.7 % SCs) of complications (two abutment screw loosenings, two decementation of the restorations, and one upper portion of the hybrid abutment decemented from the titanium base), for a success rate of 95.8 %. CONCLUSIONS Within the limits of this study (retrospective design, follow-up limited to 1 year from the delivery, and only cemented restorations included) fixed short-span implant-supported hybrid composite crowns and bridges fabricated through TSLA were clinically precise, presenting a low incidence of complications at 1 year. STATEMENT OF CLINICAL RELEVANCE The use of TSLA printing technology can open new perspectives for the treatment of small edentulous gaps with definitive implant-supported prosthetic restorations.
Collapse
Affiliation(s)
- Francesco Guido Mangano
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation.
| | | | - Henriette Lerner
- Academic Teaching and Research Institution of Johann Wolfgang Goethe University, Frankfurt, Germany
| | | | - Lusine G Khachatryan
- Department of Pediatric Diseases, N. F. Filatov Clinical Institute of Children's Health, I. M. Sechenov First State Medical University, Moscow, Russian Federation
| | - Igor Dmitrievich Gordienko
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation
| | - Oleg Admakin
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation
| |
Collapse
|
2
|
Diken Türksayar AA, Demirel M, Petersmann S, Spintzyk S, Donmez MB. Positional accuracy of a single implant analog in additively manufactured casts in biobased model resin. J Dent 2024; 146:105037. [PMID: 38703808 DOI: 10.1016/j.jdent.2024.105037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 04/25/2024] [Accepted: 05/01/2024] [Indexed: 05/06/2024] Open
Abstract
OBJECTIVES To evaluate the positional accuracy of implant analogs in biobased model resin by comparing them to that of implant analogs in model resin casts and conventional analogs in dental stone casts. METHODS Polyvinylsiloxane impressions of a partially edentulous mandibular model with a single implant were made and poured in type IV dental stone. The same model was also digitized with an intraoral scanner and additively manufactured implant casts were fabricated in biobased model resin (FotoDent biobased model) and model resin (FotoDent model 2 beige-opaque) (n = 8). All casts and the model were digitized with a laboratory scanner, and the scan files were imported into a 3-dimensional analysis software (Geomagic Control X). The linear deviations of 2 standardized points on the scan body used during digitization were automatically calculated on x-, y-, and z-axes. Average deviations were used to define precision, and 1-way analysis of variance and Tukey HSD tests were used for statistical analyses (α = 0.05). RESULTS Biobased model resin led to higher deviations than dental stone (all axes, P ≤ 0.031) and model resin (y-axis, P = 0.015). Biobased model resin resulted in the lowest precision of implant analog position (P ≤ 0.049). The difference in the positional accuracy of implant analogs of model resin and stone casts was nonsignificant (P ≥ 0.196). CONCLUSIONS Implant analogs in biobased model resin casts mostly had lower positional accuracy, whereas those in model resin and stone casts had similar positional accuracy. Regardless of the material, analogs deviated more towards mesial, while buccal deviations in additively manufactured casts and lingual deviations in stone casts were more prominent.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey
| | - Münir Demirel
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey
| | - Sandra Petersmann
- Senior Researcher, ADMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria
| | - Sebastian Spintzyk
- Associate Professor, ADMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; ITI Scholar, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
3
|
Limones A, Molinero-Mourelle P, Çakmak G, Abou-Ayash S, Delgado S, Martínez Vázquez de Parga JA, Celemín A. Impact of the superimposition methods and the designated comparison area on accuracy analyses in dentate models. J Dent 2024; 145:104939. [PMID: 38521237 DOI: 10.1016/j.jdent.2024.104939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 02/25/2024] [Accepted: 03/12/2024] [Indexed: 03/25/2024] Open
Abstract
OBJECTIVES To measure the impact of superimposition methods and the designated comparison area on accuracy analyses of dentate models using an ISO-recommended 3-dimensional (3D) metrology-grade inspection software (Geomagic Control X; 3D Systems; Rock Hill, South Carolina; USA). MATERIALS AND METHODS A dentate maxillary typodont scanned with a desktop scanner (E4; 3 Shape; Copenhagen; Denmark) and an intraoral scanner (Trios 4; 3 Shape; Copenhagen; Denmark) was used as reference. Eight groups were created based on the core features of each superimposition method: landmark-based alignment (G1); partial area-based alignment (G2); entire tooth area-based alignment (G3); double alignment combining landmark-based alignment with entire tooth area-based alignment (G4); double alignment combining partial area-based alignment with entire tooth area-based alignment (G5); initial automated quick pre-alignment (G6); initial automated precise pre-alignment (G7); and entire model area-based alignment (G8). Diverse variations of each alignment and two regions for accuracy analyses (teeth surface or full model surface) were tested, resulting in a total of thirty-two subgroups (n = 18). The alignment accuracy between experimental and reference meshes was quantified using root mean square (RMS) error as trueness and its repeatability as precision. The descriptive statistics, a factorial repeated measures analysis of variance (ANOVA) and a post hoc Tuckey multiple comparison tests were used to analyze the trueness, and precision (α = 0.05). RESULTS A total of 576 superimpositions were performed. The unique partial area-based superimposition method demonstrated the least precise alignment and was the sole group to exhibit a significant difference (p<.001). Automated initial pre-alignments demonstrated similar accuracy to other superimposition methods (p>.05). Double alignments did not result in accuracy improvement (p>.05). The designated comparison area displayed differences in both trueness (p<.001) and precision (p<.001), leading to an overall discrepancy of 8 ± 4 μm between selecting the teeth surface or full model surface. CONCLUSIONS The superimposition method choice within the tested software did not impact accuracy analyses, except when the alignment relies on a unique and reduced area, such as the palatal rugae, a single tooth, or three adjacent teeth on one side. CLINICAL SIGNIFICANCE The superimposition method choice within the tested ISO-recommended 3D inspection software did not impact accuracy analyses.
Collapse
Affiliation(s)
- Alvaro Limones
- Department of Conservative Dentistry and Prosthodontics, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain.
| | - Pedro Molinero-Mourelle
- Department of Conservative Dentistry and Prosthodontics, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain; Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Silvia Delgado
- Department of Conservative Dentistry and Prosthodontics, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | | | - Alicia Celemín
- Department of Conservative Dentistry and Prosthodontics, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
4
|
Hlaing NHMM, Lee H, Jeong Y, Park JM, Lee SJ, Lee JH. Influence of crown shade, translucency, and scan powder application on the trueness of intraoral scanners. J Dent 2024; 144:104969. [PMID: 38537881 DOI: 10.1016/j.jdent.2024.104969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 03/10/2024] [Accepted: 03/24/2024] [Indexed: 04/26/2024] Open
Abstract
OBJECTIVES Natural teeth and dental restorations present with various shades and levels of translucency. This study aimed to determine whether these variations in ceramic crowns and scan powder application affect the trueness of intraoral scanners. METHODS Eight identical premade resin typodonts, each prepared for a crown on the maxillary right second molar, were used. Eight lithium disilicate crowns, distinguished by two levels of translucency (high and low) and four shades (BL1, A2, A3, and A4), were fabricated to an identical design and cemented onto each typodont, providing eight distinct experimental groups (2 levels of translucency × 4 shades). Reference scans were acquired using a desktop scanner. Test scans were performed ten times for each experimental group using two different intraoral scanners (Medit i700 and CEREC Primescan AC), with and without the application of scan powder (n = 10). Three-dimensional metrology software was used to assess the trueness of the intraoral scan datasets. Statistical analysis involved the Kruskal-Wallis H test, Mann-Whitney U test, and independent t-test (α=0.05). RESULTS For powder-free intraoral scan datasets, the crown shade did not significantly affect trueness within each translucency group (P = 1.000). For both intraoral scanners, compared with low translucency groups, higher marked deviations were exhibited by high translucency groups (P<.001). Scan powder use largely mitigated these differences (P>.05) and enhanced the trueness of the intraoral scan (P<.01). CONCLUSIONS Shade did not significantly influence the trueness of intraoral scans. High-translucency crowns were scanned with less accuracy than were low-translucency crowns. CLINICAL SIGNIFICANCE Unlike tooth shade, translucency significantly affected the accuracy of intraoral scans. Therefore, considering the use of scan powder when scanning objects with high translucency may be beneficial.
Collapse
Affiliation(s)
- Nan Hsu Myat Mon Hlaing
- Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Hyeonjong Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Yuwon Jeong
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Ji-Man Park
- Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea; Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Sang J Lee
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Jae-Hyun Lee
- Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea; Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Gehrke P, Rashidpour M, Sader R, Weigl P. A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies. Int J Implant Dent 2024; 10:20. [PMID: 38691258 PMCID: PMC11063012 DOI: 10.1186/s40729-024-00543-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 04/23/2024] [Indexed: 05/03/2024] Open
Abstract
PURPOSE The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs). METHODS Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes. RESULTS 16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature. CONCLUSIONS The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Collapse
Affiliation(s)
- Peter Gehrke
- Department of Postgraduate Education, Master of Oral Implantology, Center for Dentistry and Oral Medicine (Carolinum), Johann Wolfgang Goethe University, Theodor-Stern-Kai 7, 60596, Frankfurt, Germany.
- Private Practice for Oral Surgery and Implant Dentistry, Bismarckstraße 27, 67059, Ludwigshafen, Germany.
| | - Mahsa Rashidpour
- Master of Oral Implantology, Center for Dentistry and Oral Medicine, Johann Wolfgang Goethe University, Frankfurt, Germany
- Private Practice for Implant dentistry and Prosthodontics, Tehran, Iran
| | - Robert Sader
- Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Medical Center of the Goethe University, Frankfurt, Germany
| | - Paul Weigl
- Head of Department of Postgraduate Education, Master of Oral Implantology, Center for Dentistry and Oral Medicine (Carolinum), Johann Wolfgang Goethe University, Theodor-Stern-Kai 7, 60596, Frankfurt, Germany
| |
Collapse
|
6
|
Donmez MB, Güven ME, Yılmaz D, Abou-Ayash S, Çakmak G, Yilmaz B. Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body. J Dent 2023; 139:104716. [PMID: 37739057 DOI: 10.1016/j.jdent.2023.104716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 08/23/2023] [Accepted: 09/19/2023] [Indexed: 09/24/2023] Open
Abstract
OBJECTIVES To evaluate the accuracy of the scans of the combined healing abutment-scan body (CHA-SB) system located at different sites of the maxilla when SBs are replaced in between each scan. METHODS Three SBs were seated into HAs located at the central incisor, first premolar, and first molar sites of a maxillary model inside a phantom head, and the model was scanned extraorally (CEREC Primescan SW 5.2). This procedure was repeated with new SBs until a total of 10 scans were performed. Standard tessellation language files of CHA-SBs at each implant location were isolated, transferred into analysis software (Geomagic Control X), and superimposed over the proprietary library files to analyze surface (root mean square), linear, and angular deviations. Trueness and precision were evaluated with one-way analysis of variance and Tukey tests. The correlation between surface and angular deviations was analyzed with Pearson's correlation (α=0.05). RESULTS Molar implant scans had the highest surface and angular deviations (P≤.006), while central incisor implant scans had higher precision (surface deviations) than premolar implant scans (P=.041). Premolar implant scans had higher accuracy than central incisor implant scans on the y-axis (P≤.029). Central incisor implant scans had the highest accuracy on the z-axis (P≤.018). A strong positive correlation was observed between surface and angular deviations (r = 0.864, P<.001). CONCLUSION Central incisor implant scans mostly had high accuracy and molar implant scans mostly had lower trueness. SBs were mostly positioned apically; however, the effect of SB replacement can be considered small as measured deviations were similar to those in previous studies and the precision of scans was high. CLINICAL SIGNIFICANCE Repositioning of scan bodies into healing abutments would be expected to result in similar single crown positioning regardless of the location of the implant, considering high scan precision with the healing abutment-scan body system. The duration of the chairside adjustments of crowns in the posterior maxilla may be longer than those in the anterior region.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Mehmet Esad Güven
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Deniz Yılmaz
- Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Ohio, United States of America
| |
Collapse
|
7
|
Hardan L, Bourgi R, Lukomska-Szymanska M, Hernández-Cabanillas JC, Zamarripa-Calderón JE, Jorquera G, Ghishan S, Cuevas-Suárez CE. Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies. J Adv Prosthodont 2023; 15:315-332. [PMID: 38205120 PMCID: PMC10774636 DOI: 10.4047/jap.2023.15.6.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 11/28/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024] Open
Abstract
PURPOSE This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, Strasbourg, France
| | | | - Juan Carlos Hernández-Cabanillas
- Health Sciences Faculty, Autonomous University of Baja California, Blvd Universitario 1000 Valle de Las Palmas, Tijuana, B.C. Mexico
| | - Juan Eliezer Zamarripa-Calderón
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| | - Gilbert Jorquera
- Department of Prosthodontics, Universidad de los Andes, Santiago, Chile
| | | | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| |
Collapse
|
8
|
Chandran K R S, Goyal M, Mittal N, George JS. Accuracy of freehand versus guided immediate implant placement: A randomized controlled trial. J Dent 2023; 136:104620. [PMID: 37454788 DOI: 10.1016/j.jdent.2023.104620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023] Open
Abstract
PURPOSE This randomized controlled trial (RCT) aimed to compare the accuracy of immediate implant placement with freehand and static guided surgery. METHODS An RCT was conducted on 61 subjects who received a total of 80 dental implants. The enrolled patients were randomly allocated to two groups: freehand surgery (control group, n = 40 implants) and static guided surgery with R2Gate® (Megagen, Gyeongbuk, South Korea, test group, n = 40 implants). Crestal and apical deviations in both mesiodistal and buccolingual dimensions, as well as depth and angular deviations, were calculated by comparing the three-dimensional (3D) position of the implant in the planning software with the final implant position, revealed by an intraoral scan of the fixture after placement. The Mann-Whitney test was used for comparative assessment. RESULTS In the freehand group (control), crestal deviations of 1.13 ± 0.89 mm and 1.00 ± 0.76 mm were found in the mesiodistal and buccolingual directions, respectively, versus 0.34 ± 0.26 mm (p<0.001) and 0.37 ± 0.24 mm (p = 0.03) in the static guided surgery group (test). Apical deviation was also higher in the freehand group (control) than in the static guided surgery group (test) in the mesiodistal (4.04 ± 1.90 mm vs. 0.97 ± 0.55 mm, p = 0.04) and buccolingual directions (3.46 ± 1.82 mm vs. 0.94 ± 0.67 mm, p = 0.02). Freehand surgery had greater angular deviation (6.09° ± 3.23) compared to guided surgery (0.83° ± 0.53, p = 0.02). However, depth deviation was similar in the freehand surgery group (2.24 ± 1.58 mm) and static guided surgery group (0.66 ± 0.43, p = 0.09). CONCLUSIONS Immediate implant placement with static guided surgery demonstrated better accuracy than freehand surgery. STATEMENT OF CLINICAL RELEVANCE Guided implant surgery showed fewer deviations compared to freehand surgery in fresh extraction sockets; therefore, the use of static guides should be given preference over the freehand modality.
Collapse
Affiliation(s)
- Segin Chandran K R
- Santosh University, No.1, Santosh Nagar, Pratap Vihar, Ghaziabad, Uttar Pradesh 201009, India.
| | - Manoj Goyal
- Santosh University, No.1, Santosh Nagar, Pratap Vihar, Ghaziabad, Uttar Pradesh 201009, India
| | - Neeti Mittal
- Santosh University, No.1, Santosh Nagar, Pratap Vihar, Ghaziabad, Uttar Pradesh 201009, India
| | - Jensy Sara George
- The Tamil Nadu Dr MGR Medical University 69, Anna Salai, Rd, Guindy, Chennai, Tamil Nadu 600032, India
| |
Collapse
|