1
|
Krishnan CS, Li KC, Tompkins GR, Lyons KM, Cannon RD. Effects of simulated long-term exposure to bottled, neutral pH electrolyzed oxidizing water on the properties of denture base resins. J Prosthet Dent 2024; 132:267.e1-267.e10. [PMID: 38622046 DOI: 10.1016/j.prosdent.2024.03.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/12/2024] [Accepted: 03/15/2024] [Indexed: 04/17/2024]
Abstract
STATEMENT OF PROBLEM Denture stomatitis can pose serious health risks, especially to older people. Chemical denture cleaning agents must be effective, yet not adversely affect the longevity of removable dentures. Ready-to-use (RTU) neutral pH electrolyzed oxidizing water (EOW) is an effective biocide against Candida albicans biofilms on denture resins, but the effects of daily disinfection with EOW on the physical and mechanical properties of resins have not been established. PURPOSE The purpose of this in vitro study was to investigate the effects of simulated long-term exposure to RTU EOW on the color, surface characteristics, and flexural strength of denture base resins. MATERIAL AND METHODS Heat-polymerized (HP), 3D printed (3D) and computer-aided design and computer-aided manufacture (CAD-CAM)-milled (CC) denture resin specimens (square: 20×20×3.3 mm; beam: 64×10×3.3 mm) were immersed in tap water (TW), RTU EOW (Neutral Anolyte ANK; Envirolyte; EOW), or a commercial denture cleaning tablet solution (Polident 3-Minute; Glaxo SmithKline; PD), mimicking a 5-minute once daily disinfection routine performed up to 3.0 years. Color and surface roughness were recorded (n=3, squares), and changes in color (∆E00) and surface roughness (∆Ra) were calculated. Flexural strength (n=12, beams) and surface hardness (n=18, beams) were measured with a universal testing machine. The fractured surfaces of specimens were examined by scanning electron microscopy and energy dispersive spectroscopy. Data were assessed by performing the Shapiro-Wilk or D'Agostino and Pearson normality tests. Two-way ANOVA or the Kruskal-Wallis test with a post hoc Tukey HSD or Dunn multiple comparisons (α=.05) was used for statistical analyses. RESULTS No significant changes were found in either color or surface roughness for HP, 3D, and CC resins after 1.5-year and 3.0-year immersion in any of the agents (P>.05). The surface hardness of 3D resins reduced by 14% with TW and by 23% with EOW and PD at 3.0 years. The flexural strengths of all 3 resins were unaffected by 3.0-year immersion (P>.05). CONCLUSIONS Simulated long-term immersion disinfection with RTU neutral pH EOW did not adversely affect the physical and mechanical properties of HP or CC denture resins.
Collapse
Affiliation(s)
- Chitra Shankar Krishnan
- Doctoral graduate, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Kai Chun Li
- Senior Lecturer, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.
| | - Geoffrey R Tompkins
- Honorary Associate Professor, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Karl M Lyons
- Professor, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Richard D Cannon
- Professor, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
2
|
Krishnan CS, Tompkins GR, Lyons KM, Cannon RD. Electrolysed oxidising water as a multi-purpose biocide in dental healthcare-A scoping review. Gerodontology 2023; 40:422-462. [PMID: 37694292 DOI: 10.1111/ger.12712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/20/2023] [Indexed: 09/12/2023]
Abstract
OBJECTIVES The objective of this scoping review was to map evidence of electrolysed oxidising water (EOW) as a biocide for dental applications of relevance to older people and identify research gaps. BACKGROUND EOW is an emerging, "green," and cost-effective biocide. There are no reviews on the landscape of EOW research as either an antiseptic or disinfectant in dental healthcare or its suitability for the oral healthcare of older people. MATERIALS AND METHODS The review follows the PRISMA Extension for Scoping Reviews (PRISMA-ScR) guidelines. Database searches (Google Scholar, PubMed, Web of Science, Ovid, Scopus and Science Direct) were undertaken using MESH terms and Boolean operators with no date restrictions, to identify full-text, original reports published in English-language peer-reviewed journals. RESULTS The search yielded 114 papers that met the inclusion/exclusion criteria. Dental applications of EOW include its use as an endodontic irrigant (39%); mouth rinse/surgical irrigant (21%); disinfectant for dental unit water lines (19%) and dental biomaterials (17%); and for antimicrobial efficacy, effects on oral tissues and on dental material properties. Most studies (83%) evaluated a single EOW formulation (acidic, moderately acidic or neutral) that was either generated at 'point-of-use' (POU; 72%), bottled ('ready-to-use', RTU; 24%) or from unspecified (3%) sources. Six reports evaluated storage-related parameters and 25 evaluated clinical applications; 89 were in vitro studies and one investigated the cost-effectiveness of POU EOW. CONCLUSIONS Neutral-pH, EOW is effective as an antimicrobial agent without deleterious effects on oral tissues. However, research on the impact of storage conditions, anti-Candida biofilm efficacy and mechanism of action against yeasts, long-term effects on denture materials and cost-effectiveness is required to establish the suitability of EOW as a multipurpose biocide for dental healthcare, including infection-control requirements relating to older people.
Collapse
Affiliation(s)
- Chitra S Krishnan
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Geoffrey R Tompkins
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Karl M Lyons
- Department of Oral Rehabilitation, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Richard D Cannon
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
3
|
Mofreh Altarawneh H, Nasser Alhajj M, Mohd Salleh N, Elkezza AHH, Adida Mahmood W. Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study. Acta Stomatol Croat 2023; 57:329-338. [PMID: 38283308 PMCID: PMC10812917 DOI: 10.15644/asc57/4/4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Accepted: 10/30/2023] [Indexed: 01/30/2024] Open
Abstract
Objectives This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods Sixty specimens (Vertex ThermoSens) were processed and divided into two main groups (n = 30) based on the type of test. Group 1 was further subdivided into two subgroups (n = 15): the control group immersed in distilled water (G1DW) and the test group immersed in Polident cleanser solution (G1PD). Group 2 was divided into three subgroups: a non-immersed group (G2None), a group immersed in distilled water (G2DW), and a group immersed in Polident cleanser solution (G2PD). Color change (∆E) and surface roughness measurements were conducted for group 1, and flexural modulus (E) test was performed for group 2. The CIE Lab* formula was utilized to calculate ∆E. An optical 3D surface analyzer and a three-point bending test were employed for surface roughness and E assessments, respectively. Data were subjected to statistical analysis using a paired-sample t-test for differences within each group before and after immersion. Furthermore, independent-sample t-tests and one-way ANOVA were conducted to analyze differences between groups. A significance level of P < 0.05 was considered. Results The results revealed a slight, statistically insignificant (P > 0.05) ∆E in all color components (L*, a*, b*) after immersion in distilled water. However, after immersion in the denture cleanser, only the L* component exhibited a statistically significant ∆E (P = 0.002), which was slight in magnitude. Additionally, a significant difference was found in the ∆E between G1DW and G1PD, with G1PD showing a higher change (P = 0.007). A significant increase in surface roughness after immersion was observed in G1PD (P = 0.017), with a notable difference between G1DW and G1PD. However, the E remained unaffected (P = 0.537). Conclusion Denture cleansers have the potential to modify the properties of thermoplastic polyamide resin. Further research is needed to explore the clinical implications of these observed changes on denture performance.
Collapse
Affiliation(s)
- Hazem Mofreh Altarawneh
- Centre of Restorative Studies, Faculty of Dentistry, University Teknologi MARA, Sungai Buloh, Jalan Hospital, Sungai Buloh, Selangor, Malaysia
| | - Mohammed Nasser Alhajj
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, Malaysia
| | - Nosizana Mohd Salleh
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, Malaysia
| | - Aeman H. H. Elkezza
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, Malaysia
| | - Wan Adida Mahmood
- Faculty of Dentistry, SEGI university, Jalan Teknologi, Kota Damansara, Petaling Jaya, Selangor, Malaysia
| |
Collapse
|
4
|
Chen MC, Chen SH, Cheng CD, Chung CH, Mau LP, Sung CE, Weng PW, Cathy Tsai YW, Shieh YS, Huang RY, Cheng WC. Mapping out the bibliometric characteristics of classic articles published in a Taiwanese academic journal in dentistry: A scopus-based analysis. J Dent Sci 2023; 18:1493-1509. [PMID: 37799889 PMCID: PMC10547996 DOI: 10.1016/j.jds.2023.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/21/2023] [Indexed: 04/09/2023] Open
Abstract
Background/purpose Since its inception, the Journal of Dental Sciences (JDS) has aimed to publish quality articles relevant to all fields in dentistry. The purpose of this study was to analyze the bibliometric characteristics and dissected associated factors correlated with citation counts of classic articles published in the JDS. Materials and method Scopus® database was used to search the qualified articles published in JDS from 2009 to 2021. The bibliometric parameters, including journal impact factor (JIF), self-citation, study design, research field, geographic, country and institute of origin, inter-institute, inter-nation collaboration, keywords hotness and associated factors correlated with citation counts of classic articles were analyzed. Results One hundred and eight articles from Scopus® database were eligible for analysis. The citation counts of classic articles ranged from 12 to 192, the average citation was 22.02. The most common study design was the in vitro/in vivo, followed by the cross-sectional study, and the major research field were Dental Materials. The most productive country and institute is Taiwan, and Chung Shan Medical University, respectively. The trend of inter-institute (71.03%) and inter-nation (11.22%) collaboration steadily increased since 2009. By using the multivariable linear regression model, Preventive and Community Dentistry in the research field significantly increased the citation counts. Conclusion Despite its limitations, the escalating trends in JIFs, and JIFs without self-citations, and inter-nation and inter-institute collaboration of classic articles were noticed. Of all the dissected associated factors, Preventive and Community Dentistry in the research field significantly increased the citation counts of classic article.
Collapse
Affiliation(s)
- Mei-Chu Chen
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
- Department of Dentistry, Tri-Service General Hospital Songshan Branch, Taipei, Taiwan
| | - Siao-Han Chen
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Chia-Dan Cheng
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Chi-Hsiang Chung
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
- School of Public Health, National Defense Medical Center, Taipei, Taiwan
| | - Lian-Ping Mau
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Department of Periodontics, Chi Mei Medical Center, Tainan, Taiwan
| | - Cheng-En Sung
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Pei-Wei Weng
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yi-Wen Cathy Tsai
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
| | - Yi-Shing Shieh
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Ren-Yeong Huang
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Wan-Chien Cheng
- School of Dentistry, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
- Graduate Institute of Dental Sciences, National Defense Medical Center, Taipei, Taiwan
| |
Collapse
|
5
|
Krishnan CS, Lyons KM, Tompkins GR, Cannon RD. Storage-related stability and antimicrobial efficacy of bottled, neutral-pH Electrolysed Oxidising Water. J Dent 2023; 137:104656. [PMID: 37567495 DOI: 10.1016/j.jdent.2023.104656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 08/01/2023] [Accepted: 08/08/2023] [Indexed: 08/13/2023] Open
Abstract
OBJECTIVES Denture stomatitis is prevalent in older people and poses serious health risks. Ready-to-use (RTU) neutral-pH Electrolysed Oxidizing Water (EOW) is an effective environmental disinfectant used in residential care settings and geriatric wards. However, the influence of storage on stability and effectiveness for denture disinfection has not been established. This research investigated the storage-related stability and antimicrobial activity of RTU EOW, and its efficacy against Candida albicans biofilms formed on denture resin. METHODS The pH, oxidation/reduction potential (mV), available chlorine content (mg/L) and [HOCl] (mM) of RTU EOW (Envirolyte, New Zealand) solutions (n = 22) were measured from bottle opening to 28 days following storage at 4 °C, room temperature (RT) or 37 °C. Staphylococcus aureus and C. albicans cells were incubated in 80% EOW for contact times (CTs) up to 15 min and colony-forming units (cfu) determined. Minimum inhibitory concentrations (MIC90 EOW-HOCl) after CTs up to five minutes were determined for S. aureus and C. albicans reference strains and clinical isolates. C. albicans-denture resin disc biofilms were assessed after a five-minute CT with undiluted EOW by XTT-metabolic activity assay. RESULTS [HOCl] remained stable when RTU EOW was stored at 4 °C or RT for five months after manufacture. One-minute CT resulted in log10 cfu reductions of >6 for S. aureus and >5 for C. albicans. Mean MIC90 for five-minute CT was 37 µM (S. aureus) and 54 µM (C. albicans). Undiluted EOW reduced C. albicans biofilm metabolic activity by 86%. CONCLUSIONS RTU neutral-pH EOW is stable over five-months storage and is an effective denture disinfectant. CLINICAL SIGNIFICANCE The efficacy of the RTU neutral EOW against C. albicans isolates and biofilms formed on denture resin surfaces supports its use as a denture disinfectant and can inform future research to assess its potential for preventing denture-related oral Candida infections in the older population, especially in resource-limited communities.
Collapse
Affiliation(s)
- C S Krishnan
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - K M Lyons
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - G R Tompkins
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - R D Cannon
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.
| |
Collapse
|
6
|
Jo YH, Lee WJ, Yoon HI. Feasibility of microencapsulated phytochemical as disinfectant for inhibition of Candida albicans proliferation on denture base produced by digital light processing. PLoS One 2023; 18:e0287867. [PMID: 37437045 DOI: 10.1371/journal.pone.0287867] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 06/14/2023] [Indexed: 07/14/2023] Open
Abstract
BACKGROUNDS A proper disinfection of denture is vital to prevent a fungal infection. A study on the feasibility of microencapsulated phytochemical as complementary disinfectant and its interaction with effervescent tablet immersion on denture base resin is lacking. OBJECTIVES The aim of this study was to examine the feasibility of phytochemical-filled microcapsules as disinfectant for the inhibition of Candida albicans (C. albicans) attachment on the denture base produced by digital light processing (DLP). METHODS 54 denture base specimens uniformly mixed with or without 5wt% phytochemical-filled microcapsules were prepared using DLP. Fungal cells were inoculated onto the surfaces of the specimens, which were divided into three different disinfection treatment groups (n = 9): 1) none, 2) sterile tap water immersion for 15 min, and 3) effervescent tablet immersion for 15 min. After each treatment, the biofilm on denture surface was stained with a crystal violet solution to measure the absorbance. The number of fungal colonies was counted as colony-forming units (CFU) per mL. Morphological changes were examined by microscopy. An aligned rank transform analysis of variance was performed to analyze the interaction of presence of microcapsule and disinfection condition, with statistical significance set at P < 0.05. RESULTS Both for the absorbance and CFU, there was no significant interaction between the presence of microcapsules and disinfection conditions (P = 0.543 and P = 0.077, respectively). The presence of microcapsules was statistically significant (both P < 0.001), while the effect of disinfection condition was not significant (P = 0.165 and P = 0.189, respectively). Morphological changes in fungi were detected in the groups containing microcapsules, whereas undamaged hyphal structures were found in those without microcapsules, irrespective of disinfection treatments. CONCLUSIONS The presence of phytochemical-filled microcapsules significantly reduced the adhesion of C. albicans and inhibited its proliferation on denture surfaces, regardless of disinfection conditions.
Collapse
Affiliation(s)
- Ye-Hyeon Jo
- Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Won-Jun Lee
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Hyung-In Yoon
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
7
|
Cárdenas AM, Campos-Bijit V, Di Francesco F, Schwarz F, Cafferata EA, Vernal R. Electrolyzed water for the microbiologic control in the pandemic dental setting: a systematic review. BMC Oral Health 2022; 22:579. [PMID: 36494635 PMCID: PMC9733258 DOI: 10.1186/s12903-022-02528-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 10/21/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Electrolyzed water has brought recent attention due to its antimicrobial properties. Indeed, electrolyzed water has been proposed to sterilize dental materials and instruments without compromising their structural integrity. In addition, electrolyzed water has been proposed as a mouthwash to control bacterial and viral oral infections without detrimental effects on the oral mucosa. However, no current consensus or evidence synthesis could indicate its potentially favorable use in the dental setting, particularly during the COVID-19 context. Therefore, this systematic review aimed to elucidate whether electrolyzed water could improve microbiologic control in the COVID-19 pandemic dental setting. METHODS MEDLINE via Pubmed, EMBASE, Cochrane's CENTRAL, Scopus, LILACS, and Web of Science databases were searched up to September 2021 to identify experimental studies utilizing electrolyzed water for eliminating microorganisms in a dental setting. Besides, a manual and a grey literature search were performed. The data selection and extraction were performed individually and in duplicate. The Risk of Bias (RoB) was assessed with the Nature Publication Quality Improvement Project (NPQIP) score sheet. The study protocol was registered at PROSPERO CRD42020206986. RESULTS From a total of 299 articles, 63 studies met the inclusion criteria. The included studies assessed several types of electrolyzed waters, which showed a high disinfection potential when used to deal with different oral conditions. Electrolyzed water demonstrated a broad antimicrobial spectrum and was highly efficient in the dental office disinfection against viruses, fungi, and bacteria, being compatible with most dental materials. In addition, electrolyzed water could protect against SARS-CoV-2 infection and contamination in the dental office. Regarding the RoB, only 35.18% of entries were answered as 'Yes', thus achieving less than half of the reporting sheet. CONCLUSION Electrolyzed water effectively disinfects contaminated surfaces, dental materials, and equipment. Therefore, their use is recommendable in the SARS-CoV-2 pandemic dental setting.
Collapse
Affiliation(s)
- Angélica M. Cárdenas
- grid.443909.30000 0004 0385 4466Periodontal Biology Laboratory, Faculty of Dentistry, Universidad de Chile, Sergio Livingstone Pohlhammer 943, 8380492 Santiago, Independencia Chile ,grid.442190.a0000 0001 1503 9395Faculty of Dentistry, Universidad Santo Tomás, Bucaramanga, Colombia ,Department of Science and Innovation, BIOMEP Research Group, Bucaramanga, Colombia
| | - Vanessa Campos-Bijit
- grid.443909.30000 0004 0385 4466Periodontal Biology Laboratory, Faculty of Dentistry, Universidad de Chile, Sergio Livingstone Pohlhammer 943, 8380492 Santiago, Independencia Chile
| | - Fabrizio Di Francesco
- grid.9841.40000 0001 2200 8888Multidisciplinary Department of Medical, Surgical and Dental Sciences, Campania University Luigi Vanvitelli, Naples, Italy
| | - Frank Schwarz
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Carolinum, Johann Wolfgang Goethe-University Frankfurt, Frankfurt, Germany
| | - Emilio A. Cafferata
- grid.7839.50000 0004 1936 9721Department of Oral Surgery and Implantology, Carolinum, Johann Wolfgang Goethe-University Frankfurt, Frankfurt, Germany ,grid.430666.10000 0000 9972 9272Department of Periodontology, School of Dentistry, Universidad Científica del Sur, Av. Paseo de la República 5544, 15074 Lima, Miraflores Peru
| | - Rolando Vernal
- grid.443909.30000 0004 0385 4466Periodontal Biology Laboratory, Faculty of Dentistry, Universidad de Chile, Sergio Livingstone Pohlhammer 943, 8380492 Santiago, Independencia Chile
| |
Collapse
|
8
|
Farah RI, Al-Haj Ali SN. Electrolyzed Water Generated On-Site as a Promising Disinfectant in the Dental Office During the COVID-19 Pandemic. Front Public Health 2021; 9:629142. [PMID: 33996714 PMCID: PMC8119747 DOI: 10.3389/fpubh.2021.629142] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 04/09/2021] [Indexed: 12/23/2022] Open
Abstract
Electrolyzed water is a safe, broad-spectrum bactericidal and viricidal agent, which can be used as a potent and effective alternative disinfectant in case of supply shortages. This report describes the on-site production of slightly acidic electrolyzed water (EW) from diluted salt solution and vinegar at a dental office using a portable EW generator unit. Such measures can ensure the safe continuity of important dental service provision for our patients during the coronavirus disease 2019 (CoVID-19) pandemic.
Collapse
Affiliation(s)
- Ra'fat Ibrahim Farah
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Buraydah, Saudi Arabia
| | - Sanaa Najeh Al-Haj Ali
- Department of Orthodontic and Pediatric Dentistry, College of Dentistry, Qassim University, Buraydah, Saudi Arabia
| |
Collapse
|
9
|
Reis R, Sipahi H, Dinc O, Kavaz T, Charehsaz M, Dimoglo A, Aydın A. Toxicity, mutagenicity and stability assessment of simply produced electrolyzed water as a wound healing agent in vitro. Hum Exp Toxicol 2020; 40:452-463. [PMID: 32909829 DOI: 10.1177/0960327120952151] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Over the last decade, electrolyzed water (EW) produced by salt and tap water has gained importance due to its antimicrobial effects. Regarding to chlorine-based compounds, EW also used in post-harvest safety of food processing and sterilization of surfaces. The latest studies suggested that EW might act as wound healing agent due to anti-infective and cell proliferative properties. In this study, we evaluated acute contact cytotoxicity in L929 mice fibroblast cells and wound healing activity of EWs in vitro. In addition, mutagenic activity was evaluated by Ames test with and without metabolic activation by S9 fraction and the stability profile of freshly prepared EWs has been followed up. According to the results, strong acid (StAEW) and mixed EW (MEW) showed dose-dependent cytotoxicity due to possible high HOCl concentration, while slightly acidic and catholyte EW (CEW) were not cytotoxic even applied directly for 30 sec. Further, StAEW and CEW showed a significant increase in L929 cell migration in scratch assay. Likewise, with/ without metabolic activation, neither of EWs had shown mutagenic profile in TA 98 and TA100 strains of Salmonella typhimurium. Follow-up of ORP (oxidation-reduction potential), pH and FCC (free chlorine concentration) showed that temperature and light were important storage conditions to maintain a stable profile particularly for ORP and FCC, which are the most important indicators for biological activity of EW. According to the present findings, it can be suggested that particularly StAEW, may represent a valuable wound healing agent with an achievable, economical and easy production system when stored under proper conditions.
Collapse
Affiliation(s)
- R Reis
- 52998Yeditepe University, Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Istanbul, Turkey
| | - H Sipahi
- 52998Yeditepe University, Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Istanbul, Turkey
| | - O Dinc
- Hamidiye Health Science Institute, Department of Biotechnology, University of Health Sciences, Istanbul, Turkey
| | - T Kavaz
- 52998Yeditepe University, Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Istanbul, Turkey
| | - M Charehsaz
- 52998Yeditepe University, Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Istanbul, Turkey
| | - A Dimoglo
- Faculty of Engineering, Department of Environmental Engineering, 121595Duzce University, Konuralp, Duzce, Turkey
| | - A Aydın
- 52998Yeditepe University, Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Istanbul, Turkey
| |
Collapse
|