1
|
Kaimal R, Dube A, Souwaileh AA, Wu JJ, Anandan S. A copper metal-organic framework-based electrochemical sensor for identification of glutathione in pharmaceutical samples. Analyst 2024; 149:947-957. [PMID: 38197180 DOI: 10.1039/d3an01714a] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
The construction of a new electrochemical sensing platform based on a copper metal-organic framework (Cu-MOF) heterostructure is described in this paper. Drop-casting Cu-MOF suspension onto the electrode surface primed the sensor for glutathione detection. The composition and morphology of the Cu-MOF heterostructure were investigated using scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), X-ray diffraction spectroscopy (XRD), Fourier transform infrared spectroscopy (FT-IR), and UV-visible spectroscopy. The Cu-MOF heterostructure can identify glutathione (GSH) with an enhanced sensitivity of 0.0437 μA μM-1 at the detection limit (LOD; 0.1 ± 0.005 μM) and a large dynamic range of 0.1-20 μM. Boosting the conductivity and surface area enhances electron transport and promotes redox processes. The constructed sensors were also adequately selective against interference from other contaminants in a similar potential window. Furthermore, the Cu-MOF heterostructure has outstanding selectivity, long-term stability, and repeatability, and the given sensors have demonstrated their capacity to detect GSH with high accuracy (recovery range = 98.2-100.8%) in pharmaceutical samples.
Collapse
Affiliation(s)
- Reshma Kaimal
- Nanomaterials & Solar Energy Conversion Lab, Department of Chemistry, National Institute of Technology, Tiruchirappalli-620015, India.
| | - Aashutosh Dube
- Nanomaterials & Solar Energy Conversion Lab, Department of Chemistry, National Institute of Technology, Tiruchirappalli-620015, India.
| | - Abdullah Al Souwaileh
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Jerry J Wu
- Department of Environmental Engineering & Science, Feng Chia University, Taichung-407, Taiwan
| | - Sambandam Anandan
- Nanomaterials & Solar Energy Conversion Lab, Department of Chemistry, National Institute of Technology, Tiruchirappalli-620015, India.
| |
Collapse
|
2
|
Xu Z, Li P, Chen H, Zhu X, Zhang Y, Liu M, Yao S. Picomolar glutathione detection based on the dual-signal self-calibration electrochemical sensor of ferrocene-functionalized copper metal-organic framework via solid-state electrochemistry of cuprous chloride. J Colloid Interface Sci 2022; 628:798-806. [PMID: 36029594 DOI: 10.1016/j.jcis.2022.08.107] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/08/2022] [Accepted: 08/16/2022] [Indexed: 11/19/2022]
Abstract
Chemical biosensing techniques are essential for food analysis and disease diagnosis. Nanomaterials with redox activity show great potential in electrochemical analysis, acting as signal labels or signal amplification unit, which can reflect the targets concentration in foods and biological samples. Here, an ultra-sensitive dual-signal intrinsic self-calibration electrochemical platform for GSH was firstly fabricated based on the novel electroactive nanomaterial of ferrocene-functionalized copper metal-organic framework (Fc-Cu-MOF). Due to the solid-state electrochemical property of cuprous chloride (CuCl), a sharp characteristic peak with an increased signal appears with the coexistence of chloride ions in solution. The stronger specific affinity between Cu+ and GSH than that of Cu+ and Cl- triggers a "crowding effect" that causes the current signal of CuCl decrease greatly. Meanwhile, the peak current of ferrocene keeps unchanged as an internal reference. Based on the ratio of the peak current variation (ΔICu/ΔIFc) as the signal output, Fc-Cu-MOF modified electrode showed wider linear range in 0.1 nM -1 μM for GSH with the detection limit as low as 0.025 nM. And the sensor was successfully applied in the determination of GSH with excellent recoveries in various real samples such as food and serum samples, providing good prospect in application of bioanalysis and food screening.
Collapse
Affiliation(s)
- Zhenjuan Xu
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| | - Peipei Li
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| | - Haoyu Chen
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| | - Xiaohua Zhu
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| | - Youyu Zhang
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| | - Meiling Liu
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China.
| | - Shouzhuo Yao
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Ministry of Education, China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, PR China
| |
Collapse
|
3
|
Hassanvand Z, Jalali F, Nazari M, Parnianchi F, Santoro C. Carbon Nanodots in Electrochemical Sensors and Biosensors: A Review. ChemElectroChem 2020. [DOI: 10.1002/celc.202001229] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
| | | | - Maryam Nazari
- Faculty of Chemistry Razi University Kermanshah Iran
| | | | - Carlo Santoro
- Department of Chemical Engineering and Analytical Science The University of Manchester The Mill Sackville Street Manchester M13PAL UK
| |
Collapse
|
4
|
Gandomi F, Marzi Khosrowshahi E, Sohouli E, Aghaei M, Saleh Mohammadnia M, Naghian E, Rahimi-Nasrabadi M. Linagliptin electrochemical sensor based on carbon nitride-β-cyclodextrin nanocomposite as a modifier. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114697] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
5
|
A new approach for electrochemical detection of organochlorine compound lindane: Development of molecular imprinting polymer with polyoxometalate/carbon nitride nanotubes composite and validation. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105012] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
6
|
Mishra P, Bhat BR. Calcium‐Induced Photoluminescence Quenching of Graphene Quantum Dots in Hard Water: A Quick Turn‐Off Sensing Approach. ChemistrySelect 2019. [DOI: 10.1002/slct.201901850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Praveen Mishra
- Catalysis and Materials LaboratoryDepartment of ChemistryNational Institute of Technology Karnataka, Surathkal Mangalore 575025 India
| | - Badekai Ramachandra Bhat
- Catalysis and Materials LaboratoryDepartment of ChemistryNational Institute of Technology Karnataka, Surathkal Mangalore 575025 India
| |
Collapse
|
7
|
Qin X, Wang Q, Geng L, Shu X, Wang Y. A “signal-on” photoelectrochemical aptasensor based on graphene quantum dots-sensitized TiO2 nanotube arrays for sensitive detection of chloramphenicol. Talanta 2019; 197:28-35. [DOI: 10.1016/j.talanta.2018.12.103] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 11/26/2018] [Accepted: 12/31/2018] [Indexed: 02/07/2023]
|
8
|
Hanko M, Švorc Ľ, Planková A, Mikuš P. Overview and recent advances in electrochemical sensing of glutathione - A review. Anal Chim Acta 2019; 1062:1-27. [PMID: 30947984 DOI: 10.1016/j.aca.2019.02.052] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 02/20/2019] [Accepted: 02/22/2019] [Indexed: 12/13/2022]
Abstract
The present paper is aimed at providing an overview of the recent advances in the electrochemical sensing of glutathione (GSH), an important electrochemically and biologically active molecule, for the period 2012-2018. Herein, the analytical performances of newly developed electrochemical methods, procedures and protocols for GSH sensing are comprehensively and critically discussed with respect to the type of method, electrodes used (new electrode modifications, advanced materials and formats), sample matrices, and basic validation parameters obtained (limit of detection, linear dynamic range, precision, selectivity/evaluation of interferences). This paper considers electrochemical methods used alone as well as the hyphenated methods with electrochemical detection (ECD), such as HPLC-ECD or CE-ECD. The practical applicability of the platforms developed for GSH detection and quantification is mostly focused on pharmaceutical and biomedical analysis. The most significant electrochemical approaches for GSH detection in multicomponent analyte samples and multicomponent matrices and for real-time in vivo GSH analysis are highlighted. The great variability in the electrochemical techniques, electrode approaches, and obtainable performance parameters, discussed in this review, brought new insights not only on current GSH and glutathione disulfide (GSSG) determinations, but, along with this, on the advances in electrochemical analysis from a more general point of view.
Collapse
Affiliation(s)
- Michal Hanko
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic
| | - Ľubomír Švorc
- Slovak University of Technology in Bratislava, Faculty of Chemical and Food Technology, Institute of Analytical Chemistry, Radlinského 9, SK-812 37, Bratislava, Slovak Republic
| | - Alexandra Planková
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic
| | - Peter Mikuš
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic; Comenius University in Bratislava, Faculty of Pharmacy, Toxicological and Antidoping Center, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic.
| |
Collapse
|
9
|
Graphene Quantum Dots Modified Screen‐printed Electrodes as Electroanalytical Sensing Platform for Diethylstilbestrol. ELECTROANAL 2019. [DOI: 10.1002/elan.201800838] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Fabrication of an ultrasensitive and selective electrochemical aptasensor to detect carcinoembryonic antigen by using a new nanocomposite. Biosens Bioelectron 2019; 129:1-6. [PMID: 30677696 DOI: 10.1016/j.bios.2018.12.047] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 12/16/2018] [Accepted: 12/21/2018] [Indexed: 01/15/2023]
Abstract
A lable-free electrochemical aptasensor was successfully developed for the sensitive detection of carcinoembryonic antigen as a tumor biomarker. To do this, a ternary nanocomposite of hemin, graphene oxide and multi-walled carbon nanotubes was used. The aptamer can be attached to the surface of a hemin, graphene oxide and multi-walled carbon nanotubes glassy carbon electrode through -NHCO- covalent bonds to form a sensing surface. Through fourier transform infrared spectroscopy and scanning electron microscopy, it was indicated that hemin can be successfully incorporated into hemin, graphene oxide and multi-walled carbon nanotubes. Hemin, which protects graphene nanosheets, also serves as an in-situ probe owing to its well-defined redox properties. Multi-walled carbon nanotubes in the modifier enhance conductivity and facilitate the electron transfer between hemin and the glassy carbon electrode. In this study, carcinoembryonic antigen got specifically bound to the aptamer, and the current changes were used for selective and specific detection of that antigen. The devised aptasensor proved to have excellent performance with a wide linear range of 1.0 × 10-15 - 1.0 × 10-8 gmL-1 and a detection limit of 0.82 fg mL-1. The inter-day and intra-day values of RSD% were obtained in the range of 0.10-2.91 and 2.21-4.56 respectively. According to the experiments conducted on real samples, it may be claimed that the proposed label-free electrochemical aptasensor is capable enough of determining carcinoembryonic antigen in clinical diagnostics.
Collapse
|
11
|
Chen C, Gan Z, Zhou K, Ma Z, Liu Y, Gao Y. Catalytic polymerization of N-methylthionine at electrochemically reduced graphene oxide electrodes. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.07.051] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
12
|
Benvidi A, Saucedo NM, Ramnani P, Villarreal C, Mulchandani A, Tezerjani MD, Jahanbani S. Electro‐oxidized Monolayer CVD Graphene Film Transducer for Ultrasensitive Impedimetric DNA Biosensor. ELECTROANAL 2018. [DOI: 10.1002/elan.201700654] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Ali Benvidi
- Department of Chemical and Environmental Engineering University of California Riverside CA 92521 USA
- Department of Chemistry Yazd University Yazd Iran
| | - Nuvia M. Saucedo
- Department of Chemical and Environmental Engineering University of California Riverside CA 92521 USA
- Department of Chemistry University of California Riverside CA 92521 USA
| | - Pankaj Ramnani
- Department of Chemical and Environmental Engineering University of California Riverside CA 92521 USA
| | - Claudia Villarreal
- Materials Science and Engineering Program University of California Riverside CA 92521 USA
| | - Ashok Mulchandani
- Department of Chemical and Environmental Engineering University of California Riverside CA 92521 USA
- Materials Science and Engineering Program University of California Riverside CA 92521 USA
| | | | | |
Collapse
|
13
|
Alarfaj NA, El-Tohamy MF, Oraby HF. CA 19-9 Pancreatic Tumor Marker Fluorescence Immunosensing Detection via Immobilized Carbon Quantum Dots Conjugated Gold Nanocomposite. Int J Mol Sci 2018; 19:E1162. [PMID: 29641488 PMCID: PMC5979385 DOI: 10.3390/ijms19041162] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 04/08/2018] [Accepted: 04/10/2018] [Indexed: 01/08/2023] Open
Abstract
The clinical detection of carbohydrate antigen 19-9 (CA 19-9), a tumor marker in biological samples, improves and facilitates the rapid screening and diagnosis of pancreatic cancer. A simple, low cost, fast, and green synthesis method to prepare a viable carbon quantum dots/gold (CQDs/Au) nanocomposite fluorescence immunosensing solution for the detection of CA 19-9 was reported. The present method is conducted by preparing glucose-derived CQDs using a microwave-assisted method. CQDs were employed as reducing and stabilizing agents for the preparation of a CQDs/Au nanocomposite. The immobilized anti-CA 19-9-labeled horseradish peroxidase enzyme (Ab-HRP) was anchored to the surface of a CQDs/Au nanocomposite by a peptide interaction between the carboxylic and amine active groups. The CA 19-9 antigen was trapped by another monoclonal antibody that was coated on the surface of microtiter wells. The formed sandwich capping antibody-antigen-antibody enzyme complex had tunable fluorescence properties that were detected under excitation and emission wavelengths of 420 and 530 nm. The increase in fluorescence intensities of the immunoassay sensing solution was proportional to the CA 19-9 antigen concentration in the linear range of 0.01-350 U mL-1 and had a lower detection limit of 0.007 U mL-1. The proposed CQDs/Au nanocomposite immunoassay method provides a promising tool for detecting CA 19-9 in human serum.
Collapse
Affiliation(s)
- Nawal Ahmad Alarfaj
- Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh 11495, Saudi Arabia.
| | - Maha Farouk El-Tohamy
- Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh 11495, Saudi Arabia.
- General Administration and Medical Affairs, Zagazig University, Zagazig 44511, Egypt.
| | - Hesham Farouk Oraby
- Department of Agronomy, Faculty of Agriculture, Zagazig University, Zagazig 44511, Egypt.
| |
Collapse
|
14
|
Yola ML, Göde C, Atar N. Molecular imprinting polymer with polyoxometalate/carbon nitride nanotubes for electrochemical recognition of bilirubin. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.06.053] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
15
|
Ghanbari K, Roushani M, Azadbakht A. Ultra-sensitive aptasensor based on a GQD nanocomposite for detection of hepatitis C virus core antigen. Anal Biochem 2017; 534:64-69. [PMID: 28728900 DOI: 10.1016/j.ab.2017.07.016] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2017] [Revised: 07/14/2017] [Accepted: 07/15/2017] [Indexed: 11/26/2022]
Abstract
In the present study, by using the aptamer proximity binding assay strategy, a novel electrochemical aptasensor is described for ultrasensitive detection of hepatitis C virus (HCV) core antigen. The immobilization surface is prepared by the modification of a glassy carbon electrode (GCE) with a graphene quantum dots (GQD). GQD were introduced as a novel and suitable substrate for aptamers through π-π stacking interactions, the richness of hydrophilic edges as well as hydrophobic plane in GQD which enhances the aptamer absorption on the electrode surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were performed at each stage of the chemical modification process to confirm the resulting surface changes. EIS technique was used as an efficient alternative detection system for HCV core antigen measurement with detection limit 3.3 pg mL-1 and two linear concentration range 10-70 pg mL-1 and 70-400 pg mL-1. Moreover, the fabricated aptasensor could accurately detect HCV core antigen concentration in human serum samples. Such an aptasensor opens a rapid, selective and sensitive route for HCV core antigen detection and provides a promising strategy for potential applications in clinical diagnostics.
Collapse
Affiliation(s)
| | | | - Azadeh Azadbakht
- Department of Chemistry, Islamic Azad University, Khorramabad Branch, Khorramabad, Iran
| |
Collapse
|
16
|
Aghaei R, Mazloum-Ardakani M, Abdollahi-Alibeik M, Moshtaghioun SM, Rezaeipoor-Anari A, Haghighijoo Z, Zamani L. A new electrochemical biosensor based on telomeric G-quadruplex DNA: In silico and experimental study of dihydropyridine derivatives potential effect on telomerase inhibition. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.04.055] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
17
|
Yola ML, Atar N. Electrochemical Detection of Atrazine by Platinum Nanoparticles/Carbon Nitride Nanotubes with Molecularly Imprinted Polymer. Ind Eng Chem Res 2017. [DOI: 10.1021/acs.iecr.7b01379] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Mehmet Lütfi Yola
- Iskenderun Technical University, Faculty of Engineering
and Natural Sciences, Department of Biomedical Engineering, Hatay, Turkey
| | - Necip Atar
- Pamukkale University, Faculty of Engineering, Department
of Chemical Engineering, Denizli, Turkey
| |
Collapse
|
18
|
Zhu X, Wu G, Lu N, Yuan X, Li B. A miniaturized electrochemical toxicity biosensor based on graphene oxide quantum dots/carboxylated carbon nanotubes for assessment of priority pollutants. JOURNAL OF HAZARDOUS MATERIALS 2017; 324:272-280. [PMID: 27810324 DOI: 10.1016/j.jhazmat.2016.10.057] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 10/14/2016] [Accepted: 10/24/2016] [Indexed: 06/06/2023]
Abstract
The study presented a sensitive and miniaturized cell-based electrochemical biosensor to assess the toxicity of priority pollutants in the aquatic environment. Human hepatoma (HepG2) cells were used as the biological recognition agent to measure the changes of electrochemical signals and reflect the cell viability. The graphene oxide quantum dots/carboxylated carbon nanotubes hybrid was developed in a facile and green way. Based on the hybrid composite modified pencil graphite electrode, the cell culture and detection vessel was miniaturized to a 96-well plate instead of the traditional culture dish. In addition, three sensitive electrochemical signals attributed to guanine/xanthine, adenine, and hypoxanthine were detected simultaneously. The biosensor was used to evaluate the toxicity of six priority pollutants, including Cd, Hg, Pb, 2,4-dinitrophenol, 2,4,6-trichlorophenol, and pentachlorophenol. The 24h IC50 values obtained by the electrochemical biosensor were lower than those of conventional MTT assay, suggesting the enhanced sensitivity of the electrochemical assay towards heavy metals and phenols. This platform enables the label-free and sensitive detection of cell physiological status with multi-parameters and constitutes a promising approach for toxicity detection of pollutants. It makes possible for automatical and high-throughput analysis on nucleotide catabolism, which may be critical for life science and toxicology.
Collapse
Affiliation(s)
- Xiaolin Zhu
- School of Environment, Northeast Normal University, Changchun 130117, PR China
| | - Guanlan Wu
- School of Environment, Northeast Normal University, Changchun 130117, PR China
| | - Nan Lu
- School of Environment, Northeast Normal University, Changchun 130117, PR China
| | - Xing Yuan
- School of Environment, Northeast Normal University, Changchun 130117, PR China.
| | - Baikun Li
- Department of Civil and Environmental Engineering, University of Connecticut, Storrs, CT 06269, United States.
| |
Collapse
|
19
|
The electrochemical behavior of core-shell CdSe/CdS magic-sized quantum dots linked to cyclodextrin for studies of the encapsulation of bioactive compounds. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3221-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
20
|
Zhao X, He D, Wang Y, Hu Y, Fu C. Au nanoparticles and graphene quantum dots co-modified glassy carbon electrode for catechol sensing. Chem Phys Lett 2016. [DOI: 10.1016/j.cplett.2016.01.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
21
|
2-Dimensional graphene as a route for emergence of additional dimension nanomaterials. Biosens Bioelectron 2016; 89:8-27. [PMID: 26992844 DOI: 10.1016/j.bios.2016.02.067] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 02/25/2016] [Accepted: 02/26/2016] [Indexed: 12/12/2022]
Abstract
Dimension has a different and impactful significance in the field of innovation, research and technologies. Starting from one-dimension, now, we all are moving towards 3-D visuals and try to do the things in this dimension. However, we still have some very innovative and widely applicable nanomaterials, which have tremendous potential in the form of 2-D only i.e. graphene. In this review, we have tried to incorporate the reported pathways used so far for modification of 2-D graphene sheets to make is three-dimensional. The modified graphene been applied in many fields like supercapacitors, sensors, catalysis, energy storage devices and many more. In addition, we have also incorporated the conversion of 2-D graphene to their various other dimensions like zero-, one- or three-dimensional nanostructures.
Collapse
|
22
|
Abstract
Graphene quantum dots (GQDs) and carbon quantum dots (CQDs) demonstrate unique properties in the electroanalysis field, including electroresistance, electrochemiluminescence, electrochemical and photoelectrochemical sensors.
Collapse
Affiliation(s)
- Ying Yulong
- State Key Laboratory of Silicon Materials
- School of Materials Science and Engineering
- Zhejiang University
- Hangzhou
- China
| | - Peng Xinsheng
- State Key Laboratory of Silicon Materials
- School of Materials Science and Engineering
- Zhejiang University
- Hangzhou
- China
| |
Collapse
|
23
|
|
24
|
Bai J, Chen Y, Li P, Sun D, Tang Y. Phosphonate-functionalized three-dimensional gold nanocomposite as a sensitive interface for facile electrochemical stripping detection of trace copper(II) ions. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.06.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
25
|
Mazloum-Ardakani M, Aghaei R, Heidari MM. Quantum-dot biosensor for hybridization and detection of R3500Q mutation of apolipoprotein B-100 gene. Biosens Bioelectron 2015; 72:362-9. [DOI: 10.1016/j.bios.2015.05.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2015] [Revised: 05/05/2015] [Accepted: 05/06/2015] [Indexed: 10/23/2022]
|
26
|
Vasilescu I, Eremia SAV, Kusko M, Radoi A, Vasile E, Radu GL. Molybdenum disulphide and graphene quantum dots as electrode modifiers for laccase biosensor. Biosens Bioelectron 2015; 75:232-7. [PMID: 26319166 DOI: 10.1016/j.bios.2015.08.051] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 08/21/2015] [Accepted: 08/22/2015] [Indexed: 10/23/2022]
Abstract
A nanocomposite formed from molybdenum disulphide (MoS2) and graphene quantum dots (GQDs) was proposed as a novel and suitable support for enzyme immobilisation displaying interesting electrochemical properties. The conductivity of the carbon based screen-printed electrodes was highly improved after modification with MoS2 nanoflakes and GQDs, the nanocomposite also providing compatible matrix for laccase immobilisation. The influence of different modification steps on the final electroanalytical performances of the modified electrode were evaluated by UV-vis absorption and fluorescence spectroscopy, scanning electron microscopy, transmission electron microscopy, X ray diffraction, electrochemical impedance spectroscopy and cyclic voltammetry. The developed laccase biosensor has responded efficiently to caffeic acid over a concentration range of 0.38-100µM, had a detection limit of 0.32µM and a sensitivity of 17.92nAµM(-1). The proposed analytical tool was successfully applied for the determination of total polyphenolic content from red wine samples.
Collapse
Affiliation(s)
- Ioana Vasilescu
- Centre of Bioanalysis, National Institute of Research and Development for Biological Sciences, Bucharest, 296 Splaiul Independentei, 060031 Bucharest, Romania
| | - Sandra A V Eremia
- Centre of Bioanalysis, National Institute of Research and Development for Biological Sciences, Bucharest, 296 Splaiul Independentei, 060031 Bucharest, Romania.
| | - Mihaela Kusko
- National Institute for Research and Development in Microtechnologies (IMT-Bucharest), 126A Erou Iancu Nicolae, 077190 Bucharest, Romania
| | - Antonio Radoi
- National Institute for Research and Development in Microtechnologies (IMT-Bucharest), 126A Erou Iancu Nicolae, 077190 Bucharest, Romania.
| | - Eugeniu Vasile
- Department of Oxide Materials and Nanomaterials, Faculty of Applied Chemistry and Material Science, University Politehnica of Bucharest, No. 1-7 Gh. Polizu Street, 011061 Bucharest, Romania
| | - Gabriel-Lucian Radu
- Centre of Bioanalysis, National Institute of Research and Development for Biological Sciences, Bucharest, 296 Splaiul Independentei, 060031 Bucharest, Romania
| |
Collapse
|
27
|
Xue Z, Hou H, Rao H, Hu C, Zhou X, Liu X, Lu X. A green approach for assembling graphene films on different carbon-based substrates and their electrocatalysis toward nitrite. RSC Adv 2015. [DOI: 10.1039/c5ra02737c] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A green strategy for assembling graphene films on various carbon-based substrates and its significant electrocatalytic activity toward nitrite oxidation.
Collapse
Affiliation(s)
- Zhonghua Xue
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| | - Huihui Hou
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| | | | - Chenxian Hu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| | - Xibin Zhou
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| | - Xiuhui Liu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| | - Xiaoquan Lu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province
- College of Chemistry & Chemical Engineering
- Northwest Normal University
- Lanzhou
- China
| |
Collapse
|