1
|
Wang Y, Nie B, Zheng S, Wu H, Chen N, Wang D. Emerging activated tungsten dust: Source, environmental behaviors, and health effects. ENVIRONMENT INTERNATIONAL 2024; 188:108774. [PMID: 38810497 DOI: 10.1016/j.envint.2024.108774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 05/18/2024] [Accepted: 05/23/2024] [Indexed: 05/31/2024]
Abstract
Fusion energy investigation has stepped to a new stage adopting deuterium and tritium as fuels from the previous stage concentrating hydrogen plasma physics. Special radiation safety issues would be introduced during this stage. In addition to industrial and military uses, tungsten is also regarded as the most promising plasma facing material for fusion reactors. During the operation of fusion reactors, tungsten-based plasma facing materials can be activated via neutron nuclear reaction. Meanwhile, activated tungsten dust can be produced when high-energy plasma interacts with the tungsten-based plasma facing materials, namely plasma wall interaction. Activated tungsten dust would be an emerging environmental pollutant with radiation toxicity containing various radionuclides in addition to the chemical toxicity of tungsten itself. Nonetheless, the historical underestimation of its environmental availability has led to limited research on tungsten compared to other environmental contaminants. This paper presents the first systematic review on the safety issue of emerging activated tungsten dust, encompassing source terms, environmental behaviors, and health effects. The key contents are as follows: 1) to detail the source terms of activated tungsten dust from aspects of tungsten basic properties, generation mechanism, physical morphology and chemical component, radioactivity, as well as potential release pathways, 2) to illustrate the environmental behaviors from aspects of atmospheric dispersion and deposition, transformation and migration in soil, as well as plant absorption and distribution, 3) to identify the toxicity and health effects from aspects of toxicity to plants, distribution in human body, as well as health effects by radiation and chemical toxicity, 4) based on the research progress, research and development issues needed are also pointed out to better knowledge of safety issue of activated tungsten dust, which would be beneficial to the area of fusion energy and ecological impact caused by the routine tungsten related industrial and military applications.
Collapse
Affiliation(s)
- Yuxuan Wang
- School of Nuclear Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Baojie Nie
- School of Nuclear Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
| | - Shanliang Zheng
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031, China
| | - Hanyu Wu
- Sino-French Institute of Nuclear Engineering and Technology, Sun Yat-sen University, Zhuhai, 519082, China
| | - Ni Chen
- School of Basic Medical Sciences, Anhui Medical University, Hefei, 230032, China
| | - Dezhong Wang
- School of Nuclear Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| |
Collapse
|
2
|
Pawar D, Lo Presti D, Silvestri S, Schena E, Massaroni C. Current and future technologies for monitoring cultured meat: A review. Food Res Int 2023; 173:113464. [PMID: 37803787 DOI: 10.1016/j.foodres.2023.113464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/30/2023] [Accepted: 09/10/2023] [Indexed: 10/08/2023]
Abstract
The high population growth rate, massive animal food consumption, fast economic progress, and limited food resources could lead to a food crisis in the future. There is a huge requirement for dietary proteins including cultured meat is being progressed to fulfill the need for meat-derived proteins in the diet. However, production of cultured meat requires monitoring numerous bioprocess parameters. This review presents a comprehensive overview of various widely adopted techniques (optical, spectroscopic, electrochemical, capacitive, FETs, resistive, microscopy, and ultrasound) for monitoring physical, chemical, and biological parameters that can improve the bioprocess control in cultured meat. The methods, operating principle, merits/demerits, and the main open challenges are reviewed with the aim to support the readers in advancing knowledge on novel sensing systems for cultured meat applications.
Collapse
Affiliation(s)
- Dnyandeo Pawar
- Microwave Materials Group, Centre for Materials for Electronics Technology (C-MET), Athani P.O, Thrissur, Kerala 680581, India.
| | - Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Sergio Silvestri
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| |
Collapse
|
3
|
VILASÓ-CADRE JE, BENÍTEZ-FERNÁNDEZ D, LÓPEZ-ÁLVAREZ IA, TOVAR-VÁZQUEZ FY, ARADA-PÉREZ MA, REYES-DOMÍNGUEZ IA. Acid-base potentiometric titration using a stainless steel electrode without oxidative treatment. Turk J Chem 2023; 47:801-813. [PMID: 38174066 PMCID: PMC10760551 DOI: 10.55730/1300-0527.3580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 08/25/2023] [Accepted: 07/19/2023] [Indexed: 01/05/2024] Open
Abstract
An AISI 304 stainless steel laminar electrode without oxidative treatment was investigated for the potentiometric titration of hydrochloric acid with sodium hydroxide. The proposed electrode was obtained from metalworking cuttings. Scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray fluorescence spectroscopy and X-ray diffraction were used to study the surface morphology and chemical composition of the electrode. The electrode showed a sensitivity of 59.18 ± 0.37 mV/pH, which was reproducible under intermediate conditions. Potentiometric titration showed a curve with deviations from pH 9.5 with respect to the glass electrode. However, this did not affect the quantification as the jumps of the curves coincided. The endpoint was 9.25 mL for both electrodes and the hydrochloric acid concentration was 0.0845 mol/L, with a deviation of 0.0004 mol/L from the standard concentration of 0.0841 mol/L. The nonartificially oxidised electrode did not show any crystalline oxide phases, whereas after oxidation it showed semicrystalline phases of iron and chromium oxides and increased the crystallinity of the steel. Despite the low content of surface oxides, stainless steel electrodes can give a Nernstian response to pH, depending on the surface characteristics of the material. This leads to the need to calibrate any electrode prior to oxidative treatment to rule out a Nernstian response without surface modification.
Collapse
Affiliation(s)
- Javier E. VILASÓ-CADRE
- Institute of Metallurgy, Autonomous University of San Luis Potosi, San Luis Potosi,
Mexico
| | - Daniel BENÍTEZ-FERNÁNDEZ
- Department of Chemistry, Faculty of Natural and Exact Sciences, University of Oriente, Santiago of Cuba,
Cuba
| | - Ilse A. LÓPEZ-ÁLVAREZ
- Institute of Metallurgy, Autonomous University of San Luis Potosi, San Luis Potosi,
Mexico
| | | | - María A. ARADA-PÉREZ
- Department of Chemistry, Faculty of Natural and Exact Sciences, University of Oriente, Santiago of Cuba,
Cuba
| | - Iván A. REYES-DOMÍNGUEZ
- Institute of Metallurgy, Autonomous University of San Luis Potosi, San Luis Potosi,
Mexico
- National Council of Science and Technology (CONACYT), Mexico City,
Mexico
| |
Collapse
|
4
|
Yang X, Duan J, Qi J, Li X, Gao J, Liang Y, Li S, Duan T, Liu W. Modulating the electron structure of Co-3d in Co 3O 4-x/WO 2.72 for boosting peroxymonosulfate activation and degradation of sulfamerazine: Roles of high-valence W and rich oxygen vacancies. JOURNAL OF HAZARDOUS MATERIALS 2023; 445:130576. [PMID: 37055981 DOI: 10.1016/j.jhazmat.2022.130576] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 11/30/2022] [Accepted: 12/07/2022] [Indexed: 06/19/2023]
Abstract
Sulfate radical (SO4•-)-based heterogonous advanced oxidation processes (AOPs) show promising potential to degrade emerging contaminants, however, regulating the electron structure of a catalyst to promote its catalytic activity is challenging. Herein, a hybrid that consists of Co3O4-x nanocrystals decorated on urchin-like WO2.72 (Co3O4-x/WO2.72) with high-valence W and rich oxygen vacancies (OVs) used to modulate the electronic structure of Co-3d was prepared. The Co3O4-x/WO2.72 that developed exhibited high catalytic activity, activating peroxymonosulfate (PMS), and degrading sulfamerazine (SMR). With the use of Co3O4-x/WO2.72, 100 % degradation of SMR was achieved within 2 min, at a pH of 7, with the reaction rate constant k1 = 3.09 min-1. Both characterizations and density functional theory (DFT) calculations confirmed the formation of OVs and the promotion of catalytic activity. The introduction of WO2.72 greatly regulated the electronic structure of Co3O4-x. Specifically, the introduction of high-valence W enabled the Co-3d band centre to be closer to the Fermi level and enhanced electrons (e-) transfer ability, while the introduction of OVs-Co in Co3O4-x promoted the activity of electrons in the Co-3d orbital and the subsequent catalytic reaction. The reactive oxygen species (ROS) were identified as •OH, SO4•-, and singlet oxygen (1O2) by quenching experiments and electron spin resonance (EPR) analysis. The DFT calculation using the Fukui index indicated the reactive sites in SMR were available for an electrophilic attack, and three degradation pathways were proposed.
Collapse
Affiliation(s)
- Xudong Yang
- The Key Laboratory of Resources and Environmental System Optimization, Ministry of Education, College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, China; Key Laboratory of Water and Sediment Sciences, Ministry of Education, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Jun Duan
- Key Laboratory of Water and Sediment Sciences, Ministry of Education, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Juanjuan Qi
- The Key Laboratory of Resources and Environmental System Optimization, Ministry of Education, College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, China.
| | - Xiuze Li
- The Key Laboratory of Resources and Environmental System Optimization, Ministry of Education, College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, China
| | - Jing Gao
- The Key Laboratory of Resources and Environmental System Optimization, Ministry of Education, College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, China
| | - Yifei Liang
- The Key Laboratory of Resources and Environmental System Optimization, Ministry of Education, College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, China
| | - Si Li
- Beijing Key Laboratory of Farmland Soil Pollution Prevention and Remediation, College of Resources and Environmental Sciences, China Agricultural University, Beijing 100193, China
| | - Tao Duan
- National Co-Innovation Center for Nuclear Waste Disposal and Environmental Safety, State Key Laboratory of Environment-friendly Energy Materials, Southwest University of Science and Technology, Mianyang 621010, Sichuan, China
| | - Wen Liu
- Key Laboratory of Water and Sediment Sciences, Ministry of Education, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
5
|
Electrochemical Techniques and Mechanisms for the Corrosion of Metals and Alloys in Sub- and Supercritical Aqueous Systems. J Supercrit Fluids 2022. [DOI: 10.1016/j.supflu.2022.105835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
6
|
Dabaghi M, Saraei N, Xu G, Chandiramohan A, Yeung J, Nguyen JP, Vukmirovic M, Selvaganapathy PR, Hirota JA. PHAIR: a biosensor for pH measurement in air-liquid interface cell culture. Sci Rep 2021; 11:3477. [PMID: 33568708 PMCID: PMC7875988 DOI: 10.1038/s41598-021-83189-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 01/28/2021] [Indexed: 01/30/2023] Open
Abstract
In many biological systems, pH can be used as a parameter to understand and study cell dynamics. However, measuring pH in live cell culture is limited by the sensor ion specificity, proximity to the cell surface, and scalability. Commercially available pH sensors are difficult to integrate into a small-scale cell culture system due to their size and are not cost-effective for disposable use. We made PHAIR-a new pH sensor that uses a micro-wire format to measure pH in vitro human airway cell culture. Tungsten micro-wires were used as the working electrodes, and silver micro-wires with a silver/silver chloride coating were used as a pseudo reference electrode. pH sensitivity, in a wide and narrow range, and stability of these sensors were tested in common standard buffer solutions as well as in culture media of human airway epithelial cells grown at the air-liquid interface in a 24 well cell culture plate. When measuring the pH of cells grown under basal and challenge conditions using PHAIR, cell viability and cytokine responses were not affected. Our results confirm that micro-wire-based sensors have the capacity for miniaturization and detection of diverse ions while maintaining sensitivity. This suggests the broad application of PHAIR in various biological experimental settings.
Collapse
Affiliation(s)
- Mohammadhossein Dabaghi
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Neda Saraei
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Gang Xu
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Abiram Chandiramohan
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Jonas Yeung
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada
| | - Jenny P Nguyen
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Milica Vukmirovic
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada
| | - Ponnambalam Ravi Selvaganapathy
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4K1, Canada
| | - Jeremy A Hirota
- Firestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4K1, Canada.
- Department of Pathology and Molecular Medicine, McMaster Immunology Research Centre, McMaster University, Hamilton, ON, L8S 4K1, Canada.
- Division of Respiratory Medicine, Department of Medicine, University of British Columbia, Vancouver, BC, V6H 3Z6, Canada.
- Department of Biology, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
7
|
Kieninger J, Weltin A, Flamm H, Urban GA. Microsensor systems for cell metabolism - from 2D culture to organ-on-chip. LAB ON A CHIP 2018; 18:1274-1291. [PMID: 29619452 DOI: 10.1039/c7lc00942a] [Citation(s) in RCA: 116] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Microsensor systems for cell metabolism are essential tools for investigation and standardization in cell culture. Electrochemical and optical read-out schemes dominate, which enable the marker-free, continuous, online recording of transient effects and deliver information beyond microscopy and end-point tests. There has been much progress in microfluidics and microsensors, but the translation of both into standard cell culture procedures is still limited. Within this critical review, we discuss different cell culture formats ranging from standard culture vessels to dedicated microfluidic platforms. Key aspects are the appropriate supply of cells, mass transport of metabolites to the sensors and generation of stimuli. Microfluidics enable the transition from static to dynamic conditions in culture and measurement. We illustrate the parameters oxygen (respiration), pH (acidification), glucose and lactate (energy metabolism) as well as short-lived reactive species (ROS/RNS) from the perspective of microsensor integration in 2D and 3D cell culture. We discuss different sensor principles and types, along with their limitations, microfabrication technologies and materials. The state-of-the-art of microsensor platforms for cell culture is discussed with respect to sensor performance, the number of parameters and timescale of application. That includes the advances from 2D culture to the increasingly important 3D approaches, with specific requirements for organotypic microtissues, spheroids and solid matrix cultures. We conclude on the current progress, potential, benefits and limitations of cell culture monitoring systems from monolayer culture to organ-on-chip systems.
Collapse
Affiliation(s)
- Jochen Kieninger
- Laboratory for Sensors, IMTEK - Department of Microsystems Engineering, University of Freiburg, Germany.
| | | | | | | |
Collapse
|
8
|
Liu M, Cheng X, Li X, Lu TJ. Corrosion behavior of low-Cr steel rebars in alkaline solutions with different pH in the presence of chlorides. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.09.016] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|