1
|
Balasubramanian K, Karuppiah C, Alagarsamy S, Mohandoss S, Arunachalam P, Govindasamy C, Velmurugan M, Yang CC, Lee HJ, Ramaraj SK. Highly sensitive detection of environmental toxic fenitrothion in fruits and water using a porous graphene oxide nanosheets based disposable sensor. ENVIRONMENTAL RESEARCH 2024; 259:119500. [PMID: 38950814 DOI: 10.1016/j.envres.2024.119500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 06/03/2024] [Accepted: 06/25/2024] [Indexed: 07/03/2024]
Abstract
Monitoring fenitrothion (FNT) residues in food and the environment is crucial due to its high environmental toxicity. In this study, we developed a sensitive, reliable electrochemical method for detecting FNT by using screen-printed carbon electrodes (SPCE) modified with porous graphene oxide (PGO) nanosheets. PGO surface properties have been meticulously characterized using advanced spectroscopic techniques. Electrochemical impedance spectroscopy and cyclic voltammetry were used to test the electrochemical properties of the PGO-modified sensor. The PGO-modified sensor exhibited remarkable sensitivity, achieving a detection limit as low as 0.061 μM and a broad linear range of 0.02-250 μM. Enhanced performance is due to PGO's high surface area and excellent electrocatalytic properties, which greatly improved electron transfer. Square wave voltammetry was used to demonstrate the sensor's efficacy as a real-time, on-site monitoring tool for FNT residues in fruit and water. The outstanding performance of the PGO/SPCE sensor underscores its applicability in ensuring food safety and environmental protection.
Collapse
Affiliation(s)
- Kavitha Balasubramanian
- PG and Research Department of Chemistry, Thiagarajar College affiliated to Madurai Kamaraj University, Madurai, Tamil Nadu, India
| | - Chelladurai Karuppiah
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea.
| | - Saranvignesh Alagarsamy
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan
| | - Sonaimuthu Mohandoss
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea
| | - Prabhakarn Arunachalam
- Department of Chemistry, College of Science, King Saud University, P.O. Box. 2455, Riyadh, 11451, Saudi Arabia
| | - Chandramohan Govindasamy
- Department of Community Health Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh, 11433, Saudi Arabia
| | - Murugan Velmurugan
- Department of Chemistry, K. Ramakrishnan College of Technology, Samayapuram, Tiruchirappalli, 621112, Tamil Nadu, India
| | - Chun-Chen Yang
- Battery Research center of Green Energy, Ming Chi University of Technology, New Taipei City, 24301, Taiwan
| | - Hye Jin Lee
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, 80 Daehakro, Buk-gu, Daegu-city, 41566, Republic of Korea.
| | - Sayee Kannan Ramaraj
- PG and Research Department of Chemistry, Thiagarajar College affiliated to Madurai Kamaraj University, Madurai, Tamil Nadu, India.
| |
Collapse
|
2
|
Yuan C, Tang C, Zhan X, Zhou M, Zhang L, Chen WT, Abdukayum A, Hu G. ZIF-67 based CoS 2 self-assembled on graphitic carbon nitride microtubular for sensitive electrochemical detection of paraquat in fruits. JOURNAL OF HAZARDOUS MATERIALS 2024; 467:133715. [PMID: 38359763 DOI: 10.1016/j.jhazmat.2024.133715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/01/2024] [Accepted: 02/01/2024] [Indexed: 02/17/2024]
Abstract
Paraquat (PQ) is a widely used and harmful herbicide that must be detected in the environment. This study reports a novel composite (CoS2-GCN) prepared by assembling cobalt disulfide (CoS2) derived from metal-organic frameworks (MOFs) on graphitic carbon nitride (GCN). An electrochemical sensor (CoS2-GCN/ glassy carbon electrode (GCE)) was successfully prepared by modifying CoS2-GCN onto a GCE to sensitively detect PQ. Different concentrations of PQ were detected using square-wave voltammetry, and the CoS2-GCN/GCE electrochemical sensor showed remarkable response signals for PQ in the range of 20 - 1000 nM and 1 - 13 μM, with a detection limit of 4.13 nM (S/N = 3). The CoS2-GCN/GCE electrochemical sensor exhibited high stability, reproducibility, and immunity to interference, which were attributed to the synergistic effects of CoS2 and GCN. In addition, the CoS2-GCN/GCE electrochemical sensor showed high applicability for the analysis of fruit samples. Therefore, the proposed sensor has potential applications in PQ detection.
Collapse
Affiliation(s)
- Chenghu Yuan
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming 650504, China; School of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China
| | - Cui Tang
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming 650504, China
| | - Xuejia Zhan
- School of Agriculture and Biology & Key Laboratory of Urban Agriculture, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Menglin Zhou
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming 650504, China
| | - Lei Zhang
- School of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.
| | - Wen-Tong Chen
- Key Laboratory of Coordination Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Jinggangshan University, Ji'an 343009, China
| | - Abdukader Abdukayum
- Xinjiang Key Laboratory of Novel Functional Materials Chemistry, College of Chemistry and Environmental Sciences, Kashi University, Kashi 844000, China
| | - Guangzhi Hu
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming 650504, China; Southwest United Graduate School, Kunming 650092, China.
| |
Collapse
|
3
|
Rajaram R, Neelakantan L. Recent advances in estimation of paraquat using various analytical techniques: A review. RESULTS IN CHEMISTRY 2022. [DOI: 10.1016/j.rechem.2022.100703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
4
|
Niu Z, Liu Y, Li X, Yan K, Chen H. Electrochemical sensor for ultrasensitive detection of paraquat based on metal-organic frameworks and para-sulfonatocalix[4]arene-AuNPs composite. CHEMOSPHERE 2022; 307:135570. [PMID: 35803381 DOI: 10.1016/j.chemosphere.2022.135570] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 06/15/2023]
Abstract
The widespread occurrence of pesticides in surface water, groundwater, soil, and food has received increasing attention towards environmental safety. Paraquat (PQ) is world widely used as a rapid sterilant herbicide and is highly toxic to humans. A simple, rapid, sensitive, and on-site detection method for the water environment to detection of PQ is urgently required. Here, we prepared a zeolite imidazole skeleton-8 (ZIF-8) and para-sulfonylcalix[4]arene (pSC4) coated gold nanoparticles composite (pSC4-AuNPs@ZIF-8) by one-step method. An electrochemical biosensor assay for PQ was established based on pSC4-AuNPs@ZIF-8 modified glassy carbon electrode through host-guest recognition of PQ and pSC4. Under the optimal conditions, recoveries of targets determination results were 92.7%-103% (n = 3), respectively. The quantity PQ detection limit was found to be 0.49 pM. Therefore, the signal amplification strategy based on pSC4-AuNPs@ZIF-8 has potential value in detecting trace pollutants in the water environment.
Collapse
Affiliation(s)
- Zhijuan Niu
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, PR China
| | - Yawen Liu
- School of Medicine, Shanghai University, Shanghai, 200444, PR China; School of Environmental and Chemical Engineering, Shanghai University, Shanghai, 200444, PR China
| | - Xin Li
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, PR China
| | - Kai Yan
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, PR China.
| | - Hongxia Chen
- School of Life Sciences, Shanghai University, Shanghai, 200444, PR China.
| |
Collapse
|
5
|
Wu Q, Tao H, Wu Y, Wang X, Shi Q, Xiang D. A Label-Free Electrochemical Aptasensor Based on Zn/Fe Bimetallic MOF Derived Nanoporous Carbon for Ultra-Sensitive and Selective Determination of Paraquat in Vegetables. Foods 2022; 11:foods11162405. [PMID: 36010404 PMCID: PMC9407144 DOI: 10.3390/foods11162405] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 08/01/2022] [Accepted: 08/08/2022] [Indexed: 12/03/2022] Open
Abstract
Paraquat (PQ) has high acute toxicity, even at low concentrations. For most people, the main pathway of exposure to PQ is through the diet. Therefore, the development of simple and efficient methods for PQ testing is critical for ensuring food safety. In this study, a new electrochemical detection strategy for paraquat is proposed based on the specific binding of PQ to its nucleic acid aptamer. Firstly, the Zn/Fe bimetallic ZIF derived nanoporous carbon (Zn/Fe-ZIF-NPC) and nickel hexacyanoferrate nanoparticles (NiHCF-NPs) were sequentially modified onto the glassy carbon electrode (GCE). NiHCF-NPs served as the signal probes, while Zn/Fe-ZIF-NPC facilitated electron transfer and effectively enhanced the sensing signal of NiHCF-NPs. Au nanoparticles (AuNPs) were then electrodeposited on the NiHCF-NPs/Zn/Fe-ZIF-NPC/GCE and then the thiolated aptamer was assembled on the AuNPs/NiHCF-NPs/Zn/Fe-ZIF-NPC/GCE via Au-S bonding. When incubated with PQ, the formation of PQ–aptamer complexes delayed the interfacial electron transport reaction of NiHCF-NPs, which caused a decrease in the current signals. As a result, simple and highly sensitive detection of PQ can be readily achieved by detecting the signal changes. A linear range was obtained from 0.001 to 100 mg/L with a detection limit as low as 0.34 μg/L. Due to the recognition specificity of the aptamer to its target molecule, the proposed method has excellent anti-interference ability. The prepared electrochemical aptasensor was successfully used for PQ assay in lettuce, cabbage and agriculture irrigation water samples with recoveries ranging from 96.20% to 104.02%, demonstrating the validity and practicality of the proposed method for PQ detection in real samples.
Collapse
Affiliation(s)
- Qiaoling Wu
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Han Tao
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
- Correspondence: ; Tel.: +86-0851-88236895
| | - Yuangen Wu
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Xiao Wang
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Qili Shi
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| | - Donglin Xiang
- School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China
- Key Laboratory of Fermentation Engineering and Biopharmacy of Guizhou Province, Guizhou University, Guiyang 550025, China
| |
Collapse
|
6
|
Somnet K, Thimoonnee S, Karuwan C, Kamsong W, Tuantranont A, Amatatongchai M. Ready-to-use paraquat sensor using a graphene-screen printed electrode modified with a molecularly imprinted polymer coating on a platinum core. Analyst 2021; 146:6270-6280. [PMID: 34549734 DOI: 10.1039/d1an01278a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We propose the fabrication of a novel ready-to-use electrochemical sensor based on a screen-printed graphene paste electrode (SPGrE) modified with platinum nanoparticles and coated with a molecularly imprinted polymer (PtNPs@MIP) for sensitive and cost-effective detection of paraquat (PQ) herbicide. Successive coating of the PtNPs surface with SiO2 and vinyl end-groups formed the PtNPs@MIP. Next, we terminated the vinyl groups with a molecularly imprinted polymer (MIP) shell. MIP was attached to the PtNPs cores using PQ as the template, methacrylic acid (MAA) as the monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as the initiator. Coating the SPGrE surface with PtNPs@MIP furnished the PQ sensor. We studied the electrochemical mechanism of PQ on the MIP sensor using cyclic voltammetry (CV) experiments. The PQ oxidation current signal appears at -1.08 V and -0.71 V vs. Ag/AgCl using 0.1 M potassium sulfate solution. Quantitative analysis was performed by anodic stripping voltammetry (ASV) using a deposition potential of -1.4 V for 60 s and linear sweep voltammetric stripping. The MIP sensor provides linearity from 0.05 to 1000 μM (r2 = 0.999), with a lower detection limit of 0.02 μM (at -0.71 V). The compact imprinted sensor gave a highly sensitive and selective signal toward PQ. The ready-to-use MIP sensor can provide an alternative approach to the determination of paraquat residue on vegetables and fruits for food safety applications.
Collapse
Affiliation(s)
- Kanpitcha Somnet
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Suphatsorn Thimoonnee
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Chanpen Karuwan
- Graphene sensor laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Wichayaporn Kamsong
- Graphene sensor laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Adisorn Tuantranont
- Graphene sensor laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| |
Collapse
|
7
|
Abstract
The use of fully printed electrochemical devices has gained more attention for the monitoring of clinical, food, and environmental analytes due to their low cost, great reproducibility, and versatility characteristics, serving as an important technology for commercial application. Therefore, a paper-based inkjet-printed electrochemical system is proposed as a cost-effective analytical detection tool for paraquat. Chromatographic paper was used as the printing substrate due its sustainable and disposable characteristics, and an inkjet-printing system deposited the conductive silver ink with no further modification on the paper surface, providing a three-electrode system. The printed electrodes were characterized with scanning electron microscopy, cyclic voltammetry, and chronopotentiometry. The proposed sensor exhibited a large surface area, providing a powerful tool for paraquat detection due to its higher analytical signal. For the detection of paraquat, square-wave voltammetry was used, and the results showed a linear response range of 3.0–100 μM and a detection limit of 0.80 µM, along with the high repeatability and disposability of the sensor. The prepared sensors were also sufficiently selective against interference, and high accuracy (recovery range = 96.7–113%) was obtained when applied to samples (water, human serum, and orange juice), showing the promising applicability of fully printed electrodes for electrochemical monitoring.
Collapse
|
8
|
Highly Sensitive Fluorescent Probe for Detection of Paraquat Based on Nanocrystals. J Fluoresc 2021; 31:559-567. [PMID: 33464455 DOI: 10.1007/s10895-020-02679-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 12/28/2020] [Indexed: 10/22/2022]
Abstract
Paraquat is one of the most toxic materials widely applied in agriculture in most countries. In the present study, a simple, innovative and inexpensive nano biosensor which is based on a thioglycolic acid (TGA) - CdTe@CdS core-shell nanocrystals (NCs) to detect paraquat, is suggested. The NCs based biosensor shows a linear working range of 10-100 nM, and limited detection of 3.5 nM. The proposed sensor that has been well used for the detection and determination of paraquat in natural water samples is collected from corn field and a canal located near to the corn field yielding recoveries as high as 98%. According to our findings, the developed biosensor shows reproducibility and high sensitivity to determine paraquat in natural water samples in which the amount of paraquat has low levels. The suggested method is efficiently applied to paraquat determination in the samples of natural water that are collected from a tap water and a canal located near to the cornfield.
Collapse
|
9
|
de Souza DC, Orzari LO, de Oliveira PR, Kalinke C, Bonacin JA, Malaspina O, Nocelli RCF, Janegitz BC. Electrochemical Sensor Based on Beeswax and Carbon Black Thin Biofilms for Determination of Paraquat in Apis mellifera Honey. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01900-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
10
|
Specific recognition of cationic paraquat in environmental water and vegetable samples by molecularly imprinted stir-bar sorptive extraction based on monohydroxylcucurbit[7]uril-paraquat inclusion complex. Mikrochim Acta 2020; 187:578. [PMID: 32975594 DOI: 10.1007/s00604-020-04491-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 08/17/2020] [Indexed: 10/23/2022]
Abstract
Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat inclusion complex. The inclusion complex that contained paraquat (PQ) as a template and monohydroxylcucurbit[7]uril ((OH)Q[7]) as a monomer was preassembled mainly through cavity inclusion interaction of (OH)Q[7] to form a one-dimensional self-assembly structure. The inclusion complex was anchored chemically on the surface of a glass stir bar with hydroxy-terminated poly(dimethylsiloxane) by the sol-gel technique to obtain a molecularly imprinted polymer-coated stir bar (MIP-SB). The molecularly imprinted coating showed specific adsorption for cationic PQ in aqueous media. Other quaternary amine compounds with a similar structure that coexisted in the solution, such as ethyl-viologen, diquat, and difenzoquat, were almost not extracted by the prepared MIP-SB. The sorptive capacity of the MIP-SB for PQ was nearly four times that of the non-imprinted stir bar (NIP-SB). The recognition mechanism indicated that the selectivity and extraction capacity resulted mainly from the imprinted cavity in the polymer that was formed by a one-dimensional assembly structure consisting of the (OH)Q[7]-PQ inclusion complex. The imprinted cavity was complementary to the PQ in shape, size, and functionality. A method to determine PQ in environmental water and vegetable samples was developed by combining MIP-SB sorptive extraction with HPLC-UV. The linear range was from 100 to 10,000 ng L-1 with a 8.2 ng L-1 detection limit for water samples and 0.02-0.85 mg kg-1 with a 0.005 mg kg-1 detection limit for vegetable samples. The limit of detection for both samples was lower than the EU-established maximum residual levels and that of other previously reported methods. The average recoveries were 70.0-96.1% with a relative standard deviation ≤ 7.6%, which showed the successful application in real sample analysis. Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat (PQ) inclusion complex, which showed a specific recognition toward cationic PQ. A method to determine PQ in environmental water and vegetable samples was established by combining MIP-SB sorptive extraction with HPLC-UV.
Collapse
|
11
|
Jerga R, Rajcová A, Müllerová V, Barták P, Cankař P, Navrátil T, Skopalová J. Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2019.113790] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Li Y, Liu L, Kuang H, Xu C. Preparing monoclonal antibodies and developing immunochromatographic strips for paraquat determination in water. Food Chem 2019; 311:125897. [PMID: 31771914 DOI: 10.1016/j.foodchem.2019.125897] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 11/07/2019] [Accepted: 11/11/2019] [Indexed: 11/16/2022]
Abstract
Paraquat (PQ) poisoning is a serious threat to human health that leads to pulmonary toxicity, neurotoxicity, and inflammation. Protecting humans from PQ exposure requires the development of rapid analytical methods for on-site detection. Here, two monoclonal antibodies against PQ were generated and an immunochromatographic assay (ICA) was exploited to determine PQ concentrations in water samples. The results showed that the monoclonal antibody 1D6 exhibited higher affinity and sensitivity, with an affinity constant of 5.4 × 108 mol/L and a limit of detection as low as 0.02 ng/mL. Without sample pretreatment, the developed ICA method provided visible limits of detection ranging from 0.25 to 1 ng/mL, and cut-off limits ranging from 1 to 5 ng/mL, where average recoveries were between 83.15% ± 1.9% and 94.49% ± 2.45% with a coefficient of variation ranging from 1.40% to 7.37%. Importantly, these observations were consistent with liquid chromatography tandem mass spectrometry. These data and results suggested that the ICA method was a reliable, portable, and high-throughput method for determining PQ residues in water samples.
Collapse
Affiliation(s)
- Yue Li
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Liqiang Liu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China.
| |
Collapse
|
13
|
Laghrib F, Bakasse M, Lahrich S, El Mhammedi MA. Electrochemical sensors for improved detection of paraquat in food samples: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 107:110349. [PMID: 31761239 DOI: 10.1016/j.msec.2019.110349] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Revised: 10/06/2019] [Accepted: 10/20/2019] [Indexed: 12/20/2022]
Abstract
Paraquat (1,10-dimethyl-4,40-dipyridinium chloride), also known as methyl viologen, is widely used as a quaternary ammonium herbicide (broadleaf weed killer) all over the world owing to its excellent effect in plant cells for crop protection and horticultural use. However, it is dangerous because of its high acute toxicity even at low concentrations. Its detection in the environment is therefore necessary. As a consequence of its widespread usage, it causes genotoxic, teratogenic as well as other environmental and ecological adverse impacts. Exposure to PQ leads to a high mortality rate because no specific drug is effective for treatment. Excessive consumption of PQ can cause cellular damage and necrosis in the brain, heart, lungs, liver, and kidneys. The diversity and sensitivity of the analyses currently required have forced the experimenter to use more advanced and efficient techniques, which can provide qualitative and quantitative results in complex environments. Electrochemical methods generally meet these criteria while offering other advantages to achieve excellent accuracy and fast handling. This paper provides an overview of the determination of PQ using electrochemical methods combined with several modified electrodes in food samples, including milk, apple juice, tomato juice, and potato juice. Emphasis was placed on the most relevant modifiers used to generate high selectivity and sensitivity such as noble metals, metallic nanoparticles, polymers, biomolecules, clay, and apatite minerals. Comprehensively, it is strongly convincing that the synergy between the sensor substrate and the modifier architecture gives the electrodes a high capacity to detect paraquat in complex matrices such as food. In line with the context, information's on the mechanism of electrooxidation or reduction of PQ has been reported with the discussion of some future prospects and some insights. To the best of our knowledge, there is no review article relating the electrochemical determination of paraquat.
Collapse
Affiliation(s)
- F Laghrib
- Univ. Sultan Moulay Slimane, Laboratoire de Chimie, Modélisation et Sciences de l'Environnement, Faculté Polydisciplinaire, 25 000, Khouribga, Morocco
| | - M Bakasse
- Univ. Chouaib Doukkali, Equipe d'Analyse des Micropolluants Organiques, Faculté de Sciences, El-Jadida, Morocco
| | - S Lahrich
- Univ. Sultan Moulay Slimane, Laboratoire de Chimie, Modélisation et Sciences de l'Environnement, Faculté Polydisciplinaire, 25 000, Khouribga, Morocco
| | - M A El Mhammedi
- Univ. Sultan Moulay Slimane, Laboratoire de Chimie, Modélisation et Sciences de l'Environnement, Faculté Polydisciplinaire, 25 000, Khouribga, Morocco.
| |
Collapse
|
14
|
Electrochemical detection of paraquat based on silver nanoparticles/water-soluble pillar[5]arene functionalized graphene oxide modified glassy carbon electrode. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113221] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
15
|
Pacheco MR, Barbosa SC, Quadrado RFN, Fajardo AR, Dias D. Glassy carbon electrode modified with carbon black and cross-linked alginate film: a new voltammetric electrode for paraquat determination. Anal Bioanal Chem 2019; 411:3269-3280. [DOI: 10.1007/s00216-019-01769-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 02/28/2019] [Accepted: 03/07/2019] [Indexed: 12/11/2022]
|
16
|
A molecularly imprinted electrochemical sensor based on Au nanocross-chitosan composites for detection of paraquat. J Solid State Electrochem 2019. [DOI: 10.1007/s10008-018-04192-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
17
|
Jerga R, Müllerová V, Štěpánková J, Barták P, Tomková H, Rozsypal J, Skopalová J. Phospholipid-modified carbon fiber brush electrode for the detection of dopamine and 3,4-dihydroxyphenylacetic acid. MONATSHEFTE FUR CHEMIE 2019. [DOI: 10.1007/s00706-019-2371-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
18
|
Electrochemistry of viologens at polypyrrole doped with sulfonated β–cyclodextrin. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.11.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Rana A, Baig N, Saleh TA. Electrochemically pretreated carbon electrodes and their electroanalytical applications – A review. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.12.019] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
20
|
Dominguez MA, Insausti M, Ilari R, Zanini GP. Fluorescence enhancement novel green analytical method for paraquat herbicide quantification based on immobilization on clay. Analyst 2019; 144:3357-3363. [DOI: 10.1039/c9an00387h] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Fluorescence emission enhancement by adsorption as a promising tool for the development of future green sensors.
Collapse
Affiliation(s)
- Marina A. Dominguez
- INQUISUR
- Departamento de Química
- Universidad Nacional del Sur (UNS)-CONICET
- 8000 Bahía Blanca
- Argentina
| | - Matías Insausti
- INQUISUR
- Departamento de Química
- Universidad Nacional del Sur (UNS)-CONICET
- 8000 Bahía Blanca
- Argentina
| | - Romina Ilari
- INQUISUR
- Departamento de Química
- Universidad Nacional del Sur (UNS)-CONICET
- 8000 Bahía Blanca
- Argentina
| | - Graciela P. Zanini
- INQUISUR
- Departamento de Química
- Universidad Nacional del Sur (UNS)-CONICET
- 8000 Bahía Blanca
- Argentina
| |
Collapse
|
21
|
Dong H, Zou F, Hu X, Zhu H, Koh K, Chen H. Analyte induced AuNPs aggregation enhanced surface plasmon resonance for sensitive detection of paraquat. Biosens Bioelectron 2018; 117:605-612. [DOI: 10.1016/j.bios.2018.06.057] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 06/27/2018] [Accepted: 06/27/2018] [Indexed: 11/26/2022]
|