1
|
Zhong Y, Liao R, He G, Liu S, Zhang J, Chen C. An electrochemical sensor based on porous heterojunction hollow NiCo-LDH/Ti 3C 2T x MXenes composites for the detection of quercetin in natural plants. Mikrochim Acta 2024; 191:572. [PMID: 39225952 DOI: 10.1007/s00604-024-06643-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Accepted: 08/19/2024] [Indexed: 09/04/2024]
Abstract
Cubic hollow-structured NiCo-LDH was synthesized using a solvothermal method. Subsequently, clay-like Ti3C2Tx MXenes were electrostatically self-assembled with NiCo layered double hydroxides (NiCo-LDH) to form composites featuring three-dimensional porous heterostructures. The composites were characterized using SEM, TEM, XRD, XPS, and FT-IR spectroscopy. Ti3C2Tx MXenes exhibit excellent electrical conductivity and hydrophilicity, providing abundant binding sites for NiCo-LDH, thereby promoting an increase in ion diffusion channels. The formation of three-dimensional porous heterostructural composites enhances charge transport, significantly improving sensor sensitivity and response speed. Consequently, the sensor demonstrates excellent electrochemical detection capability for quercetin (Qu), with a detection range of 0.1-20 µM and a detection limit of 23 nM. Additionally, it has been applied to the detection of Qu in natural plants such as onion, golden cypress, and chrysanthemum. The recovery ranged from 97.6 to 102.28%.
Collapse
Affiliation(s)
- Yu Zhong
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China
| | - Ran Liao
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China
| | - Guowen He
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China
- Key Laboratory of Low Carbon and Environmental Functional Materials of College of Hunan Province, Yiyang, 413000, Hunan, People's Republic of China
| | - Saiwen Liu
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China
- Key Laboratory of Low Carbon and Environmental Functional Materials of College of Hunan Province, Yiyang, 413000, Hunan, People's Republic of China
| | - Jin Zhang
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China
- Key Laboratory of Low Carbon and Environmental Functional Materials of College of Hunan Province, Yiyang, 413000, Hunan, People's Republic of China
| | - Chao Chen
- School of Materials and Chemical Engineering, Hunan City University, Yiyang, 413000, People's Republic of China.
- Key Laboratory of Low Carbon and Environmental Functional Materials of College of Hunan Province, Yiyang, 413000, Hunan, People's Republic of China.
| |
Collapse
|
2
|
Li H, Xiao N, Jiang M, Long J, Li Z, Zhu Z. Advances of Transition Metal-Based Electrochemical Non-enzymatic Glucose Sensors for Glucose Analysis: A Review. Crit Rev Anal Chem 2024:1-37. [PMID: 38635407 DOI: 10.1080/10408347.2024.2339955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Glucose concentration is a crucial parameter for assessing human health. Over recent years, non-enzymatic electrochemical glucose sensors have drawn considerable attention due to their substantial progress. This review explores the common mechanism behind the transition metal-based electrocatalytic oxidation of glucose molecules through classical electrocatalytic frameworks like the Pletcher model and the Hydrous Oxide-Adatom Mediator model (IHOAM), as well as the redox reactions at the transition metal centers. It further compiles the electrochemical characterization techniques, associated formulas, and their ensuing conclusions pertinent to transition metal-based non-enzymatic electrochemical glucose sensors. Subsequently, the review covers the latest advancements in the field of transition metal-based active materials and support materials used in non-enzymatic electrochemical glucose sensors in the last decade (2014-2023). Additionally, it presents a comprehensive classification of representative studies according to the active metal catalysts components involved.
Collapse
Affiliation(s)
- Haotian Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Nan Xiao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Mengyi Jiang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Jianjun Long
- Danyang Development Zone, Jiangsu Yuwell-POCT Biological Technology Co., Ltd, Danyang, China
| | - Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
3
|
Jiang D, Liu T, Chu Z, Wang Y. Advances in nanostructured material-based non-enzymatic electrochemical glucose sensors. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6344-6361. [PMID: 37971394 DOI: 10.1039/d3ay01664a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Non-enzymatic electrochemical sensors that use functional materials to directly catalyze glucose have shown great promise in diabetes management, food control, and bioprocess inspection owing to the advantages of high sensitivity, long-term stability, and low cost. Recently, in order to produce enhanced electrochemical behavior, significant efforts have been devoted to the preparation of functional materials with regular nanostructure, as it provides high specific surface area and well-defined strong active sites for electrochemical sensing. However, the structure-performance correlation in this field has not been reviewed thoroughly in the literature. This review aims to present a comprehensive report on advanced zero- to three-dimensional nanostructures based on the geometric feature and to discuss in depth their structural effects on enzyme-free electrochemical detection of glucose. It starts by illustrating the sensing principles of nanostructured materials, followed by a detailed discussion on the structural effects related to the features of each dimension. The structure-performance correlation is explored by comparing the performance derived from diverse dimensional architectures, which is beneficial for the better design of regular nanostructure to achieve efficient enzyme-free sensing of glucose. Finally, future directions of non-enzymatic electrochemical glucose sensors to solve emerging challenges and further improve the sensing performance are also proposed.
Collapse
Affiliation(s)
- Danfeng Jiang
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
| | - Tao Liu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing, Jiangsu 211816, PR China.
| | - Zhenyu Chu
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing, Jiangsu 211816, PR China.
| | - Yi Wang
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325001, PR China
| |
Collapse
|
4
|
Luo Y, Shupletsov L, Ortega Vega MR, Gutiérrez-Serpa A, Khan AH, Brunner E, Senkovska I, Kaskel S. Integration of Triphenylene-Based Conductive Metal-Organic Frameworks into Carbon Nanotube Electrodes for Boosting Nonenzymatic Glucose Sensing. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37903405 DOI: 10.1021/acsami.3c11810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/01/2023]
Abstract
The rational design and preparation of conductive metal-organic frameworks (MOFs) are alluring and challenging pathways to develop active catalysts toward electrocatalytic glucose oxidation. The hybridization of conductive MOFs with carbon nanotubes (CNTs) in the form of a composite can greatly improve the electrocatalytic performance. Herein, a facile one-step synthetic strategy is utilized to fabricate a Ni3(HHTP)2/CNT (HHTP = 2,3,6,7,10,11-hexahydroxytriphenylene) composite for nonenzymatic detection of glucose in an alkaline solution. The Ni3(HHTP)2/CNT composite, as an electrochemical glucose sensor material, exhibits superior electrocatalytic activity toward glucose oxidation with a wide detection range of up to 3.9 mM, a low detection limit of 4.1 μM (signal/noise = 3), a fast amperometric response time of <2 s, and a high sensitivity of 4774 μA mM-1 cm-2, surpassing the performance of some recently reported nonenzymatic transition-metal-based glucose sensors. In addition, the composite sensor also shows outstanding selectivity, robust long-term electrochemical stability, favorable anti-interference properties, and good reproducibility. This work displays the effectiveness of enhancing the electrocatalytic performance toward glucose detection by combing conductive MOFs with CNTs, thereby opening up an applicable and encouraging approach for the design of advanced nonenzymatic glucose sensors.
Collapse
Affiliation(s)
- Yutong Luo
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Leonid Shupletsov
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Maria Rita Ortega Vega
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Adrián Gutiérrez-Serpa
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Arafat Hossain Khan
- Chair of Bioanalytical Chemistry, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Eike Brunner
- Chair of Bioanalytical Chemistry, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Irena Senkovska
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| | - Stefan Kaskel
- Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
| |
Collapse
|
5
|
Hekmat F, Ataei Kachouei M, Taghaddosi Foshtomi S, Shahrokhian S, Zhu Z. Direct decoration of commercial cotton fabrics by binary nickel-cobalt metal-organic frameworks for flexible glucose sensing in next-generation wearable sensors. Talanta 2023; 257:124375. [PMID: 36821966 DOI: 10.1016/j.talanta.2023.124375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 01/21/2023] [Accepted: 02/14/2023] [Indexed: 02/19/2023]
Abstract
Having a prime significance in diagonsing and predicting the dangerous symptoms of chronic diseases in the early stages, special attention has been drawn by wearable glucose-sensing platforms in recent years. Herein, modified commercial cotton fabrics, decorated with binary Ni-Co metal-organic frameworks (NC-MOFs) through a one-pot scalable hydrothermal route, were directly utilized as flexible electrodes for non-enzymatic glucose amperometric sensing. Glucose sensitivities of 105.2 μA mM-1 cm-2 and 23 μA mM-1 cm-2 were acheived within two distinct linear dynamic ranges of 0.04-3.13 mM and 3.63-8.28 mM, respectively. Receiving benefits from a remarkable glucose sensitivity behavior in co-existence of iso-structures and interferences, rapid response (4.2 s), and remarkable reproducibility and repeatability, NC-MOF-modified cotton fabric electrodes are imensilly promising for developing high-performance wearable glucose sensing platfroms. The sensing performance of fabricated electrodes was further investigated in human blood serum and saliva.
Collapse
Affiliation(s)
- Farzaneh Hekmat
- Department of Chemistry, Sharif University of Technology, Azadi Avenue, Tehran, 11155-9516, Iran
| | - Matin Ataei Kachouei
- Department of Chemistry, Sharif University of Technology, Azadi Avenue, Tehran, 11155-9516, Iran
| | | | - Saeed Shahrokhian
- Department of Chemistry, Sharif University of Technology, Azadi Avenue, Tehran, 11155-9516, Iran.
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| |
Collapse
|
6
|
Zha X, Yang W, Shi L, Zeng Q, Xu J, Yang Y. 2D bimetallic organic framework nanosheets for high-performance wearable power source and real-time monitoring of glucose. Dalton Trans 2023; 52:2631-2640. [PMID: 36744545 DOI: 10.1039/d2dt03311a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Diabetics often prick their fingertips to measure the glucose levels in their blood. However, this traditional method not only causes prolonged pain but also increases the risk of infection. Hence, in this study, a non-invasive flexible glucose biosensor with high sensitivity was fabricated. Specifically, NiCo metal-organic frameworks (NiCo-MOFs) served as the electrode material of a micro-supercapacitor and sensing material of a glucose sensor. The electrochemical tests verified that the prominent sensitivity of the NiCo bimetal product is 1422.2 μA mM-1 cm-2. The micro-supercapacitor based on the as-fabricated NiCo-MOFs showed a high energy density of 11.5 mW h cm-2 at the power density 0.26 mW cm-2. In addition, the as-designed glucose device exhibited an excellent sensitivity of 0.31 μA μM-1. Furthermore, a flexible energy storage and glucose detection system was successfully prepared by further integrating the micro-supercapacitor and glucose sensor. The smart detector could accurately and conveniently measure the glucose concentration in sweat in real-time. Therefore, the wearable real-time sensing device displays feasible application for non-invasive glucose monitoring and health management.
Collapse
Affiliation(s)
- Xiaoting Zha
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Wenyao Yang
- Chongqing Engineering Research Center of New Energy Storage Devices and Applications, Chongqing University of Arts and Sciences, Chongqing, 402160, China.
| | - Liuwei Shi
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Qi Zeng
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Jianhua Xu
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Yajie Yang
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China. .,Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, 313001, China
| |
Collapse
|
7
|
Sohrabi H, Dezhakam E, Nozohouri E, Majidi MR, Orooji Y, Yoon Y, Khataee A. Advances in layered double hydroxide based labels for signal amplification in ultrasensitive electrochemical and optical affinity biosensors of glucose. CHEMOSPHERE 2022; 309:136633. [PMID: 36191760 DOI: 10.1016/j.chemosphere.2022.136633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/16/2022] [Accepted: 09/25/2022] [Indexed: 06/16/2023]
Abstract
Since the development of enzyme electrodes, the research area of glucose biosensing has seen outstanding progress and improvement. Numerous sensing platforms have been developed based on different immobilization techniques and improved electron transfer between the enzyme and electrode. Interestingly, these platforms have consistently used innovative nanostructures and nanocomposites. In recent years, layered double hydroxides (LDHs) have become key tools in the field of analytical chemistry owing to their outstanding features and benefits, such as facile synthesis, cost-effectiveness, substantial surface area, excellent catalytic performance, and biocompatibility. LDHs are often synthesized as nanomaterial composites or manufactured with specific three-dimensional structures. The purpose of this review is to illustrate the biosensing prospects of LDH-based glucose sensors and the need for improvement. First, various clinical and conventional approaches for glucose determination are discussed. The definitions, types, and various synthetic methodologies of LDHs are then explained. Subsequently, we discuss the various research studies regarding LDH-based electrochemical and optical assays, focusing on modified systems, improved electron transfers pathways (through developments in surface science), and different sensing designs based on nanomaterials. Finally, a summary of the current limitations and future challenges in glucose analysis is described, which may facilitate further development and applications.
Collapse
Affiliation(s)
- Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran
| | - Ehsan Dezhakam
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran
| | - Ehsan Nozohouri
- Department of Pharmaceutical Sciences, Jerry H. Hodge School of Pharmacy, Texas Tech University Health Sciences Center (TTUHSC), Amarillo, TX, USA
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran
| | - Yasin Orooji
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Yeojoon Yoon
- Department of Environmental and Energy Engineering, Yonsei University, Wonju, Republic of Korea
| | - Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran; Department of Environmental Engineering, Gebze Technical University, 41400, Gebze, Turkey
| |
Collapse
|
8
|
Direct decoration of carbon nanohorns with binary nickel-cobalt sulfide nanosheets towards non-enzymatic glucose sensing in human fluids. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
9
|
Kumar V, Shukla SK, Choudhary M, Gupta J, Chaudhary P, Srivastava S, Kumar M, Kumar M, Sarma DK, Yadav BC, Verma V. Ti 2C-TiO 2 MXene Nanocomposite-Based High-Efficiency Non-Enzymatic Glucose Sensing Platform for Diabetes Monitoring. SENSORS (BASEL, SWITZERLAND) 2022; 22:5589. [PMID: 35898089 PMCID: PMC9371085 DOI: 10.3390/s22155589] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 07/22/2022] [Accepted: 07/23/2022] [Indexed: 06/15/2023]
Abstract
Diabetes is a major health challenge, and it is linked to a number of serious health issues, including cardiovascular disease (heart attack and stroke), diabetic nephropathy (kidney damage or failure), and birth defects. The detection of glucose has a direct and significant clinical importance in the management of diabetes. Herein, we demonstrate the application of in-situ synthesized Ti2C-TiO2 MXene nanocomposite for high throughput non-enzymatic electrochemical sensing of glucose. The nanocomposite was synthesized by controlled oxidation of Ti2C-MXene nanosheets using H2O2 at room temperature. The oxidation results in the opening up of Ti2C-MXene nanosheets and the formation of TiO2 nanocrystals on their surfaces as revealed in microscopic and spectroscopic analysis. Nanocomposite exhibited considerably high electrochemical response than parent Ti2C MXene, and hence utilized as a novel electrode material for enzyme-free sensitive and specific detection of glucose. Developed nanocomposite-based non-enzymatic glucose sensor (NEGS) displays a wide linearity range (0.1 µM-200 µM, R2 = 0.992), high sensitivity of 75.32 μA mM-1 cm-2, a low limit of detection (0.12 μM) and a rapid response time (~3s). NEGS has further shown a high level of repeatability and selectivity for glucose in serum spiked samples. The unveiled excellent sensing performance of NEGS is credited to synergistically improved electrochemical response of Ti2C MXene and TiO2 nanoparticles. All of these attributes highlight the potential of MXene nanocomposite as a next-generation NEGS for on the spot mass screening of diabetic patients.
Collapse
Affiliation(s)
- Vinod Kumar
- Stem Cell Research Centre, Department of Hematology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow 226014, UP, India;
| | - Sudheesh K. Shukla
- Department of Biomedical Engineering, Shobhit Institute of Engineering & Technology (Deemed To-Be-University), Meerut 250110, UP, India;
| | - Meenakshi Choudhary
- Department of Solar Energy and Environmental Physics, The Swiss Institute of Dryland, Environmental and Energy Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben-Gurion 8499000, Israel;
| | - Jalaj Gupta
- Stem Cell Research Centre, Department of Hematology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow 226014, UP, India;
| | - Priyanka Chaudhary
- School of Physical & Decision Sciences, Babasaheb Bhimrao Ambedkar University (A Central University), Lucknow 226025, UP, India; (P.C.); (B.C.Y.)
| | - Saurabh Srivastava
- Department of Applied Sciences & Humanities, Rajkiya Engineering College Ambedkar Nagar, Dr. A.P.J. Abdul Kalam Technical University, Ambedkar Nagar 224122, UP, India;
| | - Mukesh Kumar
- Department of Zoology, Babasaheb Bhimrao Ambedkar University (A Central University), Lucknow 226025, UP, India;
| | - Manoj Kumar
- Indian Council of Medical Research—National Institute for Research in Environmental Health, Bhopal Bypass Road, Bhouri, Bhopal 462030, MP, India; (M.K.); (D.K.S.)
| | - Devojit Kumar Sarma
- Indian Council of Medical Research—National Institute for Research in Environmental Health, Bhopal Bypass Road, Bhouri, Bhopal 462030, MP, India; (M.K.); (D.K.S.)
| | - Bal Chandra Yadav
- School of Physical & Decision Sciences, Babasaheb Bhimrao Ambedkar University (A Central University), Lucknow 226025, UP, India; (P.C.); (B.C.Y.)
| | - Vinod Verma
- Stem Cell Research Centre, Department of Hematology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow 226014, UP, India;
| |
Collapse
|
10
|
Awais A, Arsalan M, Sheng Q, Yue T. A Non-enzymatic Hydrogen Peroxide Sensor with Enhanced Sensitivity Based on Pt Nanoparticles. ANAL SCI 2021; 37:1419-1426. [PMID: 33775976 DOI: 10.2116/analsci.20p456] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The non-enzymatic electrochemical sensing platform for hydrogen peroxide by using Pt-based nanoparticle was investigated. The characterization of PtNiCo-NPs was done by XRD, TEM, HRTEM, EDS, and XPS. A simple drop-casting technique was used to fabricate the nanomaterial on FTO electrode. The amperometric and cyclic voltammetric results illustrated that PtNiCo-NPs on FTO had excellent electrochemical performance over other mono or bimetallic materials. The catalytic performance for H2O2 sensing based on PtNiCo-NPs possessed a wide linear range from 5 μM to 16.5 mM with a low detection limit of 0.37 μM and a good sensitivity of 1374.4 μA mM-1 cm-2 at a scan rate of 20 mV s-1 (vs. Ag/AgCl). This work presents a new way to produce a ternary nanomaterial for H2O2 sensing with excellent electrochemical performance. In addition, the fabricated nanomaterial showed no interferences for common interfering agents, which indicates the high specificity of the sensor. The PtNiCo-NPs have excellent stability and good reproducibility in real samples.
Collapse
Affiliation(s)
- Azka Awais
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry, Northwest University
| | - Muhammad Arsalan
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry, Northwest University
| | - Qinglin Sheng
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry, Northwest University.,College of Food Science and Technology, Northwest University, Xi'an, Shaanxi 710069, China, Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control
| | - Tianli Yue
- College of Food Science and Technology, Northwest University, Xi'an, Shaanxi 710069, China, Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control
| |
Collapse
|
11
|
Shen M, Li W, Chen L, Chen Y, Ren S, Han D. NiCo-LDH nanoflake arrays-supported Au nanoparticles on copper foam as a highly sensitive electrochemical non-enzymatic glucose sensor. Anal Chim Acta 2021; 1177:338787. [PMID: 34482893 DOI: 10.1016/j.aca.2021.338787] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 06/17/2021] [Accepted: 06/18/2021] [Indexed: 10/21/2022]
Abstract
The detection of glucose in human blood is of great importance in the diagnosis and prevention of diabetes. In this work, we fabricated a novel electrochemical non-enzymatic glucose sensor, NiCo-LDH nanoflake arrays-supported Au nanoparticles on copper foam (NiCo-LDH@ Au/Cu) by galvanic replacement and electrodeposition methods. Owing to the synergistic effect of three-dimensional (3D) architecture of Cu foam, high electrocatalytic activity of Au nanoparticles and NiCo-LDH nanoflake arrays, the NiCo-LDH@Au/Cu electrode exhibits excellent electrocatalytic ability for glucose oxidation in NaOH solution. Under optimized conditions, the NiCo-LDH@Au/Cu electrode shows excellent activity with a linear range from 0.5 to 3000 μM at the potential of 0.50 V (vs. Ag/AgCl), a low detection limit of 0.23 μM (S/N = 3), an ultra-prompt response time of 0.5 s, and a high sensitivity of 23100 μA mM-1 cm-2, as well as good selectivity and stability. Furthermore, the as-fabricated non-enzymatic glucose sensor was successfully applied to the glucose detection in human serum as a promising candidate in the development of electrochemical non-enzymatic glucose sensor.
Collapse
Affiliation(s)
- Mao Shen
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China
| | - Wei Li
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China
| | - Lei Chen
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China
| | - Yuxiang Chen
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China
| | - Shibin Ren
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China.
| | - Deman Han
- College of Pharmaceutical and Materials Engineering, Taizhou University, Taizhou 318000, China.
| |
Collapse
|
12
|
Arsalan M, Qiao X, Awais A, Wang Y, Yang S, Sheng Q, Yue T. Enhanced Sensitive Electrochemical Sensor for Simultaneous Catechol and Hydroquinone Detection by Using Ultrasmall Ternary Pt‐based Nanomaterial. ELECTROANAL 2021. [DOI: 10.1002/elan.202100026] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Muhammad Arsalan
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Xiujuan Qiao
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Azka Awais
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Yahui Wang
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Shuying Yang
- College of Food Science and Technology Northwest University Xi'an Shaanxi 710069 China
- Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control Shaanxi Xi'an 710069 China
| | - Qinglin Sheng
- College of Food Science and Technology Northwest University Xi'an Shaanxi 710069 China
- Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control Shaanxi Xi'an 710069 China
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Tianli Yue
- College of Food Science and Technology Northwest University Xi'an Shaanxi 710069 China
- Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control Shaanxi Xi'an 710069 China
| |
Collapse
|
13
|
Lakhdari D, Guittoum A, Benbrahim N, Belgherbi O, Berkani M, Vasseghian Y, Lakhdari N. A novel non-enzymatic glucose sensor based on NiFe(NPs)-polyaniline hybrid materials. Food Chem Toxicol 2021; 151:112099. [PMID: 33677039 DOI: 10.1016/j.fct.2021.112099] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/14/2021] [Accepted: 02/26/2021] [Indexed: 02/08/2023]
Abstract
This article was focused on the elaboration of NiFe-Polyaniline glucose sensors via electrochemical technique. Firstly, the PANi (polyaniline) fibers were synthesized by oxidation of the monomer aniline on FTO (fluorine tin oxide) substrate. Secondly, the Nickel-Iron nanoparticles (NiFe (NPs)) were obtained by the Chronoamperometry method on the Polyaniline surface. The NiFe-PANi hybrid electrode was characterized by scanning electron microscopy (SEM), force atomic microscopy (AFM), Fourier-transformed infrared (FTIR), and X-ray diffraction (XRD). The electrochemical glucose sensing performance of the NiFe alloy nanoparticle was studied by cyclic voltammetry and amperometry. The fabricated glucose sensor Ni-Fe hybrid material exhibited many remarkable sensing performances, such as low-response time (4 s), sensitivity (1050 μA mM-1 cm-2), broad linear range (from 10 μM -1 mM), and low limit of detection (LOD) (0.5 μM, S/N = 3). The selectivity, reliability, and stability of the NiFe hybrid material for glucose oxidation were also investigated. All the results demonstrated that the NiFe-PANi/FTO hybrid electrode is very promising for application in electrochemical glucose sensing.
Collapse
Affiliation(s)
- Delloula Lakhdari
- Research Center in Industrial Technologies CRTI, P.O. Box 64, Cheraga, 16014, Algiers, Algeria; Laboratoire de Physique et Chimie des Matériaux (LPCM), Université Mouloud Mammeri de Tizi-Ouzou, RP 15000, Algeria.
| | - Abderrahim Guittoum
- Nuclear Research Centre of Algiers, 2 Bd Frantz Fanon, Bp 399, Alger-Gare, Algiers, Algeria
| | - Nassima Benbrahim
- Laboratoire de Physique et Chimie des Matériaux (LPCM), Université Mouloud Mammeri de Tizi-Ouzou, RP 15000, Algeria
| | - Ouafia Belgherbi
- Research Center in Industrial Technologies CRTI, P.O. Box 64, Cheraga, 16014, Algiers, Algeria
| | - Mohammed Berkani
- Laboratoire Biotechnologies, Ecole Nationale Supérieure de Biotechnologie, Ville Universitaire Ali Mendjeli, BP E66 25100, Constantine, Algeria.
| | - Yasser Vasseghian
- Center for Advanced Chemistry, Institute of Research and Development, Duy Tan University, 03 Quang Trung, Da Nang 550000, Vietnam; The Faculty of Environmental and Chemical Engineering, Duy Tan University, 03 Quang Trung, Da Nang 550000, Vietnam.
| | - Nadjem Lakhdari
- Laboratoire Biotechnologies, Ecole Nationale Supérieure de Biotechnologie, Ville Universitaire Ali Mendjeli, BP E66 25100, Constantine, Algeria.
| |
Collapse
|
14
|
Preparation and comparison of colloid based Ni50Co50(OH)2/BOX electrocatalyst for catalysis and high performance nonenzymatic glucose sensor. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105486] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
15
|
Awais A, Arsalan M, Sheng Q, Zheng J, Yue T. Rational Design of Highly Efficient One‐pot Synthesis of Ternary PtNiCo/FTO Nanocatalyst for Hydroquinone and Catechol Sensing. ELECTROANAL 2020. [DOI: 10.1002/elan.202060166] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Azka Awais
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Muhammad Arsalan
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Qinglin Sheng
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
- College of Food Science and Technology Northwest University Xi'an Shaanxi 710069 China
- Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control Shaanxi Xi'an 710069 China
| | - Jianbin Zheng
- College of Chemistry & Materials Science/Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education/Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry Northwest University Xi'an Shaanxi 710069 China
| | - Tianli Yue
- College of Food Science and Technology Northwest University Xi'an Shaanxi 710069 China
- Laboratory of Nutritional and Healthy Food-Individuation Manufacturing Engineering/Research Center of Food Safety Risk Assessment and Control Shaanxi Xi'an 710069 China
| |
Collapse
|
16
|
Shishegari N, Sabahi A, Manteghi F, Ghaffarinejad A, Tehrani Z. Non-enzymatic sensor based on nitrogen-doped graphene modified with Pd nano-particles and NiAl layered double hydroxide for glucose determination in blood. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114285] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
17
|
Wang L, Miao X, Qu Y, Duan C, Wang B, Yu Q, Gao J, Song D, Li Y, Yin Z. Rattle-type Au@NiCo LDH hollow core-shell nanostructures for nonenzymatic glucose sensing. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2019.113810] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
18
|
Aziz A, Asif M, Ashraf G, Azeem M, Majeed I, Ajmal M, Wang J, Liu H. Advancements in electrochemical sensing of hydrogen peroxide, glucose and dopamine by using 2D nanoarchitectures of layered double hydroxides or metal dichalcogenides. A review. Mikrochim Acta 2019; 186:671. [DOI: 10.1007/s00604-019-3776-z] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 08/21/2019] [Indexed: 01/19/2023]
|
19
|
Usman M, Pan L, Farid A, Riaz S, Khan AS, Peng ZY, Khan MA. Ultra-fast and highly sensitive enzyme-free glucose sensor based on 3D vertically aligned silver nanoplates on nickel foam-graphene substrate. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113342] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Sun F, Wang S, Wang Y, Zhang J, Yu X, Zhou Y, Zhang J. Synthesis of Ni-Co Hydroxide Nanosheets Constructed Hollow Cubes for Electrochemical Glucose Determination. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2938. [PMID: 31277330 PMCID: PMC6651393 DOI: 10.3390/s19132938] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 06/18/2019] [Accepted: 07/01/2019] [Indexed: 12/14/2022]
Abstract
Hierarchical Ni-Co double transition metal hydroxide nanosheets have been explored as an effective strategy for the design of nonenzymatic glucose sensors. Ni-Co hydroxide nanosheets constructed hollow cubes were successfully synthesized by using Cu2O cubes as templates and subsequently etched by Na2S2O3 to achieve a hollow cubic structure. The molar ratio between Ni and Co was tuned by varying the precursor ratio of NiCl2 and CoCl2. It was observed by transmission electron microscopy (TEM) that the increasing Ni precursor resulted in particle morphology, and the increasing ratio of the Co precursor resulted in more lamellar morphology. The sample with the composition of Ni0.7Co0.3(OH)2 displayed the best performance for glucose sensing with high selectivity (1541 μA mM-1 cm-2), low detection limit (3.42 µM with S/N = 3), and reasonable selectivity. Similar strategies could be applied for the design of other electrode materials with high efficiency for nonenzymatic glucose determination.
Collapse
Affiliation(s)
- Fengchao Sun
- School of Materials Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
- School of Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Shutao Wang
- College of Science, China University of Petroleum (East China), Qingdao 266580, China
| | - Yuqi Wang
- College of Science, China University of Petroleum (East China), Qingdao 266580, China
| | - Jingtong Zhang
- School of Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Xinping Yu
- School of Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Yan Zhou
- School of Materials Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China.
- School of Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China.
- College of Science, China University of Petroleum (East China), Qingdao 266580, China.
| | - Jun Zhang
- School of Materials Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
- School of Chemical Engineering, China University of Petroleum (East China), Qingdao 266580, China
| |
Collapse
|
21
|
Al-Sultan AA, Saleh MM, Touny AH. Direct and indirect electrocatalysis on nickel phosphate-based catalysts. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.05.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
22
|
Cui J, Li Z, Liu K, Li J, Shao M. A bifunctional nonenzymatic flexible glucose microsensor based on CoFe-Layered double hydroxide. NANOSCALE ADVANCES 2019; 1:948-952. [PMID: 36133216 PMCID: PMC9419660 DOI: 10.1039/c8na00231b] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 01/06/2019] [Indexed: 06/16/2023]
Abstract
A bifunctional flexible glucose microsensor has been successfully fabricated by directly growing a layered double hydroxide nanosheet array (LDH-NSA) on Ni wire. The as-obtained CoFe-LDH-NSA exhibits promising performances in electrochemical and colorimetric detection of glucose with high sensitivity and selectivity. This work demonstrates an effective strategy to fabricate multi-functional glucose nonenzyme sensors.
Collapse
Affiliation(s)
- Junya Cui
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology Beijing 100029 China +86-10-64425385 +86-10-64412131
| | - Zhenhua Li
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology Beijing 100029 China +86-10-64425385 +86-10-64412131
| | - Ke Liu
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology Beijing 100029 China +86-10-64425385 +86-10-64412131
| | - Jianming Li
- Petroleum Geology Research and Laboratory Center, Research Institute of Petroleum Exploration & Development (RIPED), PetroChina Beijing 100083 China
| | - Mingfei Shao
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology Beijing 100029 China +86-10-64425385 +86-10-64412131
| |
Collapse
|
23
|
Asif M, Aziz A, Azeem M, Wang Z, Ashraf G, Xiao F, Chen X, Liu H. A review on electrochemical biosensing platform based on layered double hydroxides for small molecule biomarkers determination. Adv Colloid Interface Sci 2018; 262:21-38. [PMID: 30428998 DOI: 10.1016/j.cis.2018.11.001] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 11/01/2018] [Accepted: 11/02/2018] [Indexed: 02/05/2023]
Abstract
The development of layered double hydroxides (LDHs), also known as anionic clays with uniform distribution of metal ions and facile exchangeability of intercalated anions, are now appealing an immense deal of attention in synthesis of multifunctional materials. In electrochemical biosensors, LDHs provide stable environment for immobilization of enzymes or other sensing materials and play crucial roles in development of clinical chemistry, point-of-care devices through analysis of various small molecule metabolites excreted by biological processes which in turn serve as molecular biomarkers for medical diagnostics. In this review, we summarize the recent development in fabrication of LDH based nanoarchitectures and their electrocatalytic applications in ultrasensitive in vitro determination of conventional biomarkers, i.e., H2O2, glucose, dopamine and other biomolecules. Moreover, detailed discussion has been compiled to differentiate electrochemical enzymatic and nonenzymatic biosensors, to evaluate useful concentration ranges of H2O2 and glucose for analytical circumstances and to distinguish tumorigenic and normal cells via quantifying the released H2O2 efflux from living cells. Here, we envision that electrochemical sensing platform based on structurally integrated LDH nanohybrids with highly conducting substrates will assist as diseases diagnostic probe further enhancing diagnosis as well as therapeutic window for chronic diseases. Finally, the perspective for fabrication and assembly of LDH electrode is proposed for the future innovation of electrochemical biosensors with high performance making them more reliable for in vitro diagnostics.
Collapse
|