1
|
Ficek M, Cieślik M, Janik M, Brodowski M, Sawczak M, Bogdanowicz R, Ryl J. Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications. Mikrochim Acta 2023; 190:410. [PMID: 37736868 PMCID: PMC10516795 DOI: 10.1007/s00604-023-05991-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Accepted: 09/06/2023] [Indexed: 09/23/2023]
Abstract
This paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials' architecture and the receptor immobilisation procedures. The study presents a two-step modification process involving the electroreduction of diazonium salt at the BDDPE and the immobilisation of antibodies using zero-length cross-linkers for a selective impedimetric biosensor of Haemophilus influenzae (Hi). The incorporation of diamond nanosheets into BDDPE leads to enhanced charge transfer and electrochemical behaviour, demonstrating greatly improved electrochemically active surface area compared with unmodified screen-printed electrodes (by 44% and 10% on average for [Ru(NH3)6]Cl2 and K3[Fe(CN)6], respectively). The presented sensing system shows high specificity towards protein D in Hi bacteria, as confirmed by negative controls against potential interference from other pathogens, with an estimated tolerance limit for interference under 12%. The Hi limit of detection by electrochemical impedance spectroscopy was 1 CFU/mL (measured at - 0.13 V vs BDDPE pseudo-reference), which was achieved in under 10 min, including 5 min sample incubation in the presence of the analyte.
Collapse
Affiliation(s)
- Mateusz Ficek
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Mateusz Cieślik
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland
- Department of Analytical Chemistry, University of Gdańsk, Wita Stwosza 63, 80-308, Gdańsk, Poland
| | - Monika Janik
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland
- Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warsaw, Poland
| | - Mateusz Brodowski
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Mirosław Sawczak
- Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14, Gdańsk, Poland
| | - Robert Bogdanowicz
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland.
| | - Jacek Ryl
- Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdańsk, Poland.
| |
Collapse
|
2
|
Chiticaru EA, Damian CM, Pilan L, Ioniță M. Label-Free DNA Biosensor Based on Reduced Graphene Oxide and Gold Nanoparticles. BIOSENSORS 2023; 13:797. [PMID: 37622883 PMCID: PMC10452912 DOI: 10.3390/bios13080797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/26/2023]
Abstract
Currently available DNA detection techniques frequently require compromises between simplicity, speed, accuracy, and cost. Here, we propose a simple, label-free, and cost-effective DNA detection platform developed at screen-printed carbon electrodes (SPCEs) modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs). The preparation of the detection platform involved a two-step electrochemical procedure based on GO reduction onto SPCEs followed by the electrochemical reduction of HAuCl4 to facilitate the post-grafting reaction with AuNPs. The final sensor was fabricated by the simple physical adsorption of a single-stranded DNA (ssDNA) probe onto a AuNPs-RGO/SPCE electrode. Each preparation step was confirmed by morphological and structural characterization using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy, respectively. Furthermore, the electrochemical properties of the modified electrodes have been investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results demonstrated that the introduction of AuNPs onto RGO/SPCEs led to an enhancement in surface conductivity, a characteristic that favored an increased sensitivity in detection. The detection process relied on the change in the electrochemical signal induced by the binding of target DNA to the bioreceptor and was particularly monitored by the change in the charge transfer resistance of a [Fe(CN)6]4-/3- redox couple added in the test solution.
Collapse
Affiliation(s)
- Elena Alina Chiticaru
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh Polizu 1-7, 011061 Bucharest, Romania;
| | - Celina Maria Damian
- Advanced Polymer Materials Group, University Politehnica of Bucharest, Gh Polizu 1-7, 011061 Bucharest, Romania;
| | - Luisa Pilan
- Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, University Politehnica of Bucharest, Gh Polizu 1-7, 011061 Bucharest, Romania
| | - Mariana Ioniță
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh Polizu 1-7, 011061 Bucharest, Romania;
- Advanced Polymer Materials Group, University Politehnica of Bucharest, Gh Polizu 1-7, 011061 Bucharest, Romania;
| |
Collapse
|
3
|
López-Balladares O, Espinoza-Montero PJ, Fernández L. Electrochemical Evaluation of Cd, Cu, and Fe in Different Brands of Craft Beers from Quito, Ecuador. Foods 2023; 12:foods12112264. [PMID: 37297508 DOI: 10.3390/foods12112264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/31/2023] [Accepted: 05/31/2023] [Indexed: 06/12/2023] Open
Abstract
The presence of heavy metals in craft beers can endanger human health if the total metal content exceeds the exposure limits recommended by sanitary standards; in addition, they can cause damage to the quality of the beer. In this work, the concentration of Cd(II), Cu(II), and Fe(III) was determined in 13 brands of craft beer with the highest consumption in Quito, Ecuador, by differential pulse anodic stripping voltammetry (DPASV), using as boron-doped diamond (BDD) working electrode. The BDD electrode used has favorable morphological and electrochemical properties for the detection of metals such as Cd(II), Cu(II), and Fe(III). A granular morphology with microcrystals with an average size between 300 and 2000 nm could be verified for the BDD electrode using a scanning electron microscope. Double layer capacitance of the BDD electrode was 0.01412 μF cm-2, a relatively low value; Ipox/Ipred ratios were 0.99 for the potassium ferro-ferricyanide system in BDD, demonstrating that the redox process is quasi-reversible. The figures of merit for Cd(II), Cu(II), and Fe(III) were; DL of 6.31, 1.76, and 1.72 μg L-1; QL of 21.04, 5.87, and 5.72 μg L-1, repeatability of 1.06, 2.43, and 1.34%, reproducibility of 1.61, 2.94, and 1.83% and percentage of recovery of 98.18, 91.68, and 91.68%, respectively. It is concluded that the DPASV method on BDD has acceptable precision and accuracy for the quantification of Cd(II), Cu(II), and Fe(III), and it was verified that some beers did not comply with the permissible limits of food standards.
Collapse
Affiliation(s)
- Oscar López-Balladares
- Escuela de Ciencias Químicas, Pontificia Universidad Católica del Ecuador, Quito 170525, Ecuador
- Facultad de Ciencias Químicas, Universidad Central del Ecuador, Quito 170521, Ecuador
| | | | - Lenys Fernández
- Escuela de Ciencias Químicas, Pontificia Universidad Católica del Ecuador, Quito 170525, Ecuador
| |
Collapse
|
4
|
Dettlaff A, Rycewicz M, Ficek M, Wieloszyńska A, Szala M, Ryl J, Bogdanowicz R. Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection. Mikrochim Acta 2022; 189:270. [PMID: 35789434 PMCID: PMC9255478 DOI: 10.1007/s00604-022-05371-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 06/05/2022] [Indexed: 11/28/2022]
Abstract
An efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface-functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode activation treatment was necessary. Different configurations of low- and heavy-boron doping NDFs were evaluated. The electrode kinetics was analyzed using electrochemical procedures: cyclic voltammetry and electrochemical impedance spectroscopy. The quasi-reversible electrochemical process was reported in each studied case. The studies allowed confirmation of the CV peak-to-peak separation of 63 mV and remarkably high heterogeneous electron transfer rate constant reaching 6.1 × 10−2 cm s−1 for 10 k ppm [B]/[C] thin NDF fitted topside at the G-PLA electrode. Differential pulse voltammetry was used for effective 2,4,6-trinitrotoluene (TNT) detection at the studied electrodes with a 87 ppb limit of detection, and wide linearity range between peak current density and the analyte concentration (0.064 to 64 ppm of TNT). The reported electrode kinetic differences originate primarily from the boron-dopant concentration in the diamond and the various contents of the non-diamond carbon phase.
Collapse
Affiliation(s)
- Anna Dettlaff
- Faculty of Chemistry, Department of Energy Conversion and Storage, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland. .,Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland.
| | - Michał Rycewicz
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Mateusz Ficek
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Aleksandra Wieloszyńska
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Mateusz Szala
- Military University of Technology, S. Kaliskiego 2, 00-908, Warsaw, Poland
| | - Jacek Ryl
- Institute of Nanotechnology and Materials Engineering and Advanced Materials Center, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Robert Bogdanowicz
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| |
Collapse
|
5
|
Madej M, Lipińska J, Kapica R, Kędzierska-Sar A, Frątczak E, Kochana J, Baś B, Tyczkowski J. Innovative modification of the surface of screen-printed carbon electrodes by nanofilms directly deposited in cold acrylonitrile plasma. Electrochem commun 2022. [DOI: 10.1016/j.elecom.2022.107263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|
6
|
Mavrikis S, Göltz M, Rosiwal S, Wang L, Ponce de León C. Carbonate-Induced Electrosynthesis of Hydrogen Peroxide via Two-Electron Water Oxidation. CHEMSUSCHEM 2022; 15:e202102137. [PMID: 34935302 DOI: 10.1002/cssc.202102137] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 12/10/2021] [Indexed: 06/14/2023]
Abstract
Electrochemical synthesis of hydrogen peroxide (H2 O2 ), via the two-electron water oxidation reaction (2e- WOR), is an attractive method for the sustainable production of valuable chemicals in place of oxygen during water electrolysis. While the majority of 2e- WOR studies have focussed on electrocatalyst design, little research has been carried out on the selection of the supporting electrolyte. In this work, we investigate the impact of potassium carbonate (K2 CO3 ) electrolytes, and their key properties, on H2 O2 production. We found that at electrolyte pH values (>9.5) where the carbonate anion (CO3 2- ) was prevalent in the mixture, a 26.5 % increase in the Faraday efficiency (%FE) for H2 O2 production was achieved, compared to bicarbonate (HCO3 - ) dominant solutions. Utilising boron-doped diamond (BDD) in highly concentrated K2 CO3 solutions, current densities of up to 511 mA cm-2 (in 4 m) and %FEs of 91.5 % (in 5 m) could be attained. The results presented in this work highlight the influence of CO3 2- on electrochemical H2 O2 generation via the 2e- WOR and provide novel pathways to produce desirable commodities at the anode during electrochemical water splitting.
Collapse
Affiliation(s)
- Sotirios Mavrikis
- Electrochemical Engineering Laboratory, Energy Technology Research Group Faculty of Engineering and Physical Sciences, University of Southampton Highfield Campus, University Road, Southampton, SO17 1BJ, United Kingdom
- National Centre for Advanced Tribology at Southampton (nCATS) Faculty of Engineering and Physical Sciences, University of Southampton Highfield Campus, University Road, Southampton, SO17 1BJ, United Kingdom
| | - Maximilian Göltz
- Materials Science and Engineering for Metals, Faculty of Engineering Friedrich-Alexander University of Erlangen-Nürnberg, 91058, Erlangen, Germany
| | - Stefan Rosiwal
- Materials Science and Engineering for Metals, Faculty of Engineering Friedrich-Alexander University of Erlangen-Nürnberg, 91058, Erlangen, Germany
| | - Ling Wang
- National Centre for Advanced Tribology at Southampton (nCATS) Faculty of Engineering and Physical Sciences, University of Southampton Highfield Campus, University Road, Southampton, SO17 1BJ, United Kingdom
| | - Carlos Ponce de León
- Electrochemical Engineering Laboratory, Energy Technology Research Group Faculty of Engineering and Physical Sciences, University of Southampton Highfield Campus, University Road, Southampton, SO17 1BJ, United Kingdom
| |
Collapse
|
7
|
Olejnik A, Karczewski J, Dołęga A, Siuzdak K, Cenian A, Grochowska K. Simple synthesis route for fabrication of protective photo-crosslinked poly(zwitterionic) membranes for application in non-enzymatic glucose sensing. J Biomed Mater Res B Appl Biomater 2021; 110:679-690. [PMID: 34592065 DOI: 10.1002/jbm.b.34946] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 09/03/2021] [Accepted: 09/09/2021] [Indexed: 01/20/2023]
Abstract
This work focuses on the fabrication of non-enzymatic glucose sensing materials based on laser-formed Au nanoparticles embedded in Ti-textured substrates. Those materials possess good catalytic activity toward glucose oxidation in 0.1 × phosphate buffered saline as well as resistance to some interferants, such as ascorbic acid, urea, and glycine. The electrodes are further coated with three different polymers, that is, Nafion, photo-crosslinked poly(zwitterions) based on sulfobetaine methacrylate, and a hybrid membrane consisting of both polymers. Both the optimal integrity of the material and its catalytic activity toward glucose oxidation were maintained by the hybrid membranes with a large excess of poly(zwitterions) (mass ratio 20:1). The chemical structures of the as-formed membranes are confirmed by Fourier transform infrared spectroscopy. Due to the zwitterionic nature of the coating, the electrodes are resistant to biofouling and maintain electrochemical activity toward glucose for 4 days. Moreover, due to the synergistic effect of both Nafion and poly(zwitterions), the interference from the two compounds, namely, from acetylsalicylic acid and acetaminophen, was diminished. Besides the presence of polymer membranes, the electrode possesses a sensitivity of 36.8 μA cm-2 mM-1 in the linear range of 0.4-12 mM, while the limit of detection was estimated to be 23 μM. Finally, the electrodes are stable, and their response is not altered even by 1,000 bending cycles.
Collapse
Affiliation(s)
- Adrian Olejnik
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland.,Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics, Gdańsk University of Technology, Gdańsk, Poland
| | - Jakub Karczewski
- Faculty of Applied Physics and Mathematics, Gdańsk University of Technology, Gdańsk, Poland
| | - Anna Dołęga
- Department of Inorganic Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Katarzyna Siuzdak
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| | - Adam Cenian
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| | - Katarzyna Grochowska
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Gdańsk, Poland
| |
Collapse
|
8
|
Handschuh-Wang S, Wang T, Tang Y. Ultrathin Diamond Nanofilms-Development, Challenges, and Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2007529. [PMID: 34041849 DOI: 10.1002/smll.202007529] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 12/24/2020] [Indexed: 06/12/2023]
Abstract
Diamond is a highly attractive material for ample applications in material science, engineering, chemistry, and biology because of its favorable properties. The advent of conductive diamond coatings and the steady demand for miniaturization in a plethora of economic and scientific fields resulted in the impetus for interdisciplinary research to develop intricate deposition techniques for thin (≤1000 nm) and ultra-thin (≤100 nm) diamond films on non-diamond substrates. By virtue of the lowered thickness, diamond coatings feature high optical transparency in UV-IR range. Combined with their semi-conductivity and mechanical robustness, they are promising candidates for solar cells, optical devices, transparent electrodes, and photochemical applications. In this review, the difficulty of (ultra-thin) diamond film development and production, introduction of important stepping stones for thin diamond synthesis, and summarization of the main nucleation procedures for diamond film synthesis are elucidated. Thereafter, applications of thin diamond coatings are highlighted with a focus on applications relying on ultrathin diamond coatings, and the excellent properties of the diamond exploited in said applications are discussed, thus guiding the reader and enabling the reader to quickly get acquainted with the research field of ultrathin diamond coatings.
Collapse
Affiliation(s)
- Stephan Handschuh-Wang
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, 518055, China
| | - Tao Wang
- Functional Thin Films Research Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yongbing Tang
- Functional Thin Films Research Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
- Key Laboratory of Advanced Materials Processing & Mold, Ministry of Education, Zhengzhou University, Zhengzhou, 450002, China
| |
Collapse
|